VLD-2500VACUUM LEAK DETECTOR
OPERATING MANUAL
www.USAIndustries.com (713) 941-3797 • (800) 456-8721
315 State Street • S. Houston, TX 77587
M-OM-VLD2500-1.1
VLD-2500 OPERATING INSTRUCTION MANUAL www.USAIndustries.com | (713) 941-3797©2020, USA Industries, Inc.
M-OM-VLD2500-1.1
VLD-2500 VACUUM LEAK DETECTOROPERATING INSTRUCTIONS
Seal the far-end of the suspect tube(s) using either a Rubber Tapered tube plug or the “T” Handle tool provided in the VLD Kit, designed for the specific tube O.D. and gauge.
1
On the opposite end of the tube(s) you just plugged, insert the cone-shaped nozzle into the suspect tube(s).
2
Pull the trigger on the VLD-2500 and monitor the gauge at the top of the unit.
90PSIG should read between 15 - 18Hg
3
Rubber Tapered Plug
VLD-2500 OPERATING INSTRUCTION MANUAL www.USAIndustries.com | (713) 941-3797©2020, USA Industries, Inc.
M-OM-VLD2500-1.1
NOTE: When testing tubes that have dirt or scale build-up, it may become necessary to replace or clean the � lter within the VLD unit.
Hold trigger and monitor gauge for approximately 10 seconds.
If the tube does not hold a vacuum, a drop in pressure will be detected on the gauge, indicating a leak in the tube.
Larger leaks will show more quickly than smaller ones.
4
VLD-2500 VACUUM LEAK DETECTOROPERATING INSTRUCTIONS
5
VLD-2500 VACUUM LEAK DETECTOR PARTS LIST
VLD KIT
#VLD-P-ET-2
#VLD-C-FILTER
#VLD-P-NNA
NOZZLE FOR 3/8” - 1-1/8” ID TUBES(OTHER SIZES AVAILABLE)
#VLD-P-ET-2.5
#VLD-P-SC-1 #VLD-C-GAUGE
#VLD-P-VT
#VLD-P-T-1
KIT INCLUDES:
VLD-2500 Detector Gun
2 Nozzles
“T”-Handle
Rubber Plugs
Carrying Case
#VLD-P-VS-1
#VLD-P-V-1
#VLD-P-TS
#VLD-P-TSS
#VLD-P-AI
#VLD-P-TAPER PIN
#VLD-P-VN
#VLD-P-VNO #VLD-P-VNO
#VLD-P-HOUSING
Recommended