View
38
Download
5
Category
Preview:
DESCRIPTION
MEASURING INSTRUMENT MULTI - HANDY 2020. Connect the sensor Switch on the device Start to measure. Only as complete kit available. TECHNICAL DATA. 2 Measuring inputs for analogue sensors; Signals: 0 - 20 mA, 4 - 20 mA 1 Calculating channel for difference - PowerPoint PPT Presentation
Citation preview
MEASURING INSTRUMENT
MULTI - HANDY 2020
Only as complete kit available
Connect the sensor
Switch on the device
Start to measure
TECHNICAL DATA
2 Measuring inputs for analogue sensors; Signals: 0 - 20 mA, 4 - 20 mA
1 Calculating channel for difference
Measuring rate: 1 ms (1 kHz)
Resolution: 12 Bit
TECHNICAL DATA
LCD display (75 * 50 mm), adjustable background illumination
Measuring value memory: 128 KB, 1 series ofmeasurement, 60.000 measuring values, 2 Bytes /
measuring value
Easy handling- 4 soft keys
HANDLING
Initialization menu appears for approx. 2 seconds
2020
MAIN MENU
F1 (Peak) Min. / Max. mode
F2 No function
F3 (Start) Starting of storage
F4 Illumination on / off
Measuring value centered if only one ISDS sensor is connected
Battery display divided into 10 steps
MAIN MENU
Measuring values of all connected sensors are shown
If the measuring values have the same variable, a third value will be displayed
This is used for the calculation of difference
MIN / MAX MODE
F1 (Meas) Min. / Max. and normal mode
F2 (Del) Delete Min. / Max. memory
F3 (Start) Starting of storage
F4 Illumination on / off
Display if only one sensor is connected
MEMORY MENU
F1 (Peak) Min. / Max. and normal mode
F2 No function
F3 (Stop) Stop storage
F4 Illumination on / off
Only real measuring channels can be stored. Representation of calculated channels of a storage only possible with HydrocomsysWin.
Display of storage status in 50 steps
Storage can be transferred via USB to a PC.
New storage overwrites the old storage.
SETUP MENU
F1 (Down) One line down
F2 (Up) One line up
F3 (Slct) Select actual parameter
F4 (OK) Storage of parameter and return to the main menu
Activation via soft keys F1, F2 and F2
Languages: Italian, German, English, Spanish, French, Dutch, Swedish, Polish. Possibility to program your own language, e.g. Cyrillic
ISDS: On / Off
Unit: Selection between SI and US
ISDS
If no ISDS sensor is connected to the measuring instrument, only a pressure measurement (0 - 20 mA) can be carried out.
The ISDS-function has to be switched off.
Adjustable measuring ranges: 6 - 60 - 100 - 200 - 400 - 600 bar
ISDS
Without ISDS, 3 channels (2x measuring inputs, 1x calculated channel) are displayed and both measuring inputs are stored.
All ISDS sensors with output signal 0/4-20 mA are recognized automatically:
Temperature sensor Volume flow rate sensor with f/I-converter (NEW)
RESET MENUF1 (No) Stop the reset, return to the
main menu
F2 No function
F3 No function
F4 Carry out a reset and return to the main menuActivation via soft keys F1, F2 and F3
After system breakdown, a software reset can be carried out
All parameters are adjusted according to manufacturing adjustments and the memory will be completely deleted
COMMUNICATION WITH PC
HydrocomsysWin Basic: Blocks a certain part of the functions if MH 2020 is connected
Communication with PC via USB 2.0 interface
Extendable to full version by ordering release code which has to be entered in: Extras -> Configuration
HydrocomsysWin: Extras – Configuration
COMMUNICATION WITH PC
Interface: RS232 has to be selected
Baudrate: 57600 has to be selected
COM: In this case COM 3 has to be selected
HydrocomsysWin: Extras – Configuration Windows: System configuration - Hardware
MEASURING KIT
Details will follow…
HydrocomsysWin Basic:
Software as download on your homepage available
Included pressure transducer HT-PD:
Suitable only with instrument MH 2020
MEASURING KITFollowing kits are available:
Description Measuring range Part no.
2020-pp-600-600 2 x 0 to 600 bar (0 to 60 MPa) 3160-18-18-69.00
2020-pp-400-400 2 x 0 to 400 bar (0 to 40 MPa) 3160-15-15-69.00
2020-pp-200-200 2 x 0 to 200 bar (0 to 20 MPa) 3160-10-10-69.00
2020-pp-60-600 1 x 0 to 60 bar (0 to 6 MPa)
1 x 0 to 600 bar (0 to 60 MPa)
3160-21-18-69.00
2020-pp-60-60 2 x 0 to 60 bar (0 to 60 MPa) 3160-21-21-69.00
2020-pp-6-60 1 x -1 to 6 bar (-1 to 0,6 MPa)
1 x 0 to 60 bar (0 to 6 MPa)
3160-32-21-69.00
Recommended