NetAXS-123 Hardware Overview

Preview:

DESCRIPTION

Honeywell NETAXS 123 general overview

Citation preview

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Honeywell Knowledge Series

NetAXS-123

Single Door PoE Installation

Part 2 – Hardware Overview

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

NetAXS-123 Modular Access Control System

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Enclosure Options

• 1, 2 and 3 door installations

• Universal Input 4 Amp Power Supply provides power for:

Standard (Metal)Compact (Plastic)

• High-Impact Plastic Enclosure

• Mount at the Door

• 1 Door POE • Controller

• REX (RTE)

• Readers

• Door Locks and Strikes

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Mounting Options

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Net-AXS-123 Building Blocks

Controller Board with1 Door of I/O

1 Door I/O Board

NXD1

2 DoorI/O Board

NXD2

Field upgradable from a 1-door

to a 2 or 3-door controller

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Net-AXS-123 Building Blocks

• Simple Installation– Power down panel

– Plug in add-on board – no wiring required

– Power up panel

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

NetAXS-123 Door Centric

Controller Only Controller plus1-Door Expansion

Controller plus2-Door Expansion

Three Doors One or Two Readers per Door

Two Doors One or Two Readers per Door

One Door One or Two Readers

Compact Enclosure Standard (Metal) Enclosure Standard (Metal) Enclosure

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Ordering - Made Simple

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

1 Door @ Compact Enclosure + PoE

Compact Enclosure

PoE powers panel and lock

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

1 Door In/Out @ Compact Enclosure + PoE

Compact Enclosure

PoE powers panel and lock

When using In and Out readers, BOTH readers must have HOLD lines

InReader

OutReaderIn

ReaderOut

Reader

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

2 Doors @ Compact Enclosure + 12VDC

Compact Enclosure

PoEonly

powers panel

1- DoorAdd-On Board

(NXD1)

4A, 12VDCPower Supply(Lock Power)

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

1 Door @ Standard Enclosure (internal 12VDC)

Built-in4A, 12VDC

Power Supply(Panel and Lock Power)

1 Door

Standard (metal) Enclosure

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

2 Doors @ Standard Enclosure (internal 12VDC)

Built-in4A, 12VDC

Power Supply(Panel and Lock Power)

2 Doors

Standard (metal) Enclosureincludes

1-Door Add-On BoardNXD1

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

3 Doors @ Standard Enclosure (internal 12VDC)

Built-in4A, 12VDC

Power Supply(Panel and Lock Power)

3 Doors

Standard (metal) Enclosureincludes

2-Door Add-On BoardNXD2

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Installation Scenario

Classroom / Site

Installation Scenario

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Classroom Installation Overview

A small business office with a handful of employees and a manager. The manager is looking for basic card access to prevent costs associated with giving out brass keys.

One door w/door strike (output relay #1) Unlocked during day (9am-5pm M-F)

No egress or door position switch

1 manager , 5 employees Access levels

Master – Always access 24/7 Employee – 6am-6pm M-F

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211 17

NetAXS-123Control Panel

Reader

Electric Strike

Classroom Installation Overview

PoESwitch/Hub

PC with Web Browser

CAT-5

Parts ListOne – NC-NX1P10 kit (includes one

compact enclosure and control panel, one Omni10 reader)

One – Door strike (12 VDC/450 ma)

One – PoE switch or injector

18 awg – 6c t/s18 awg

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Installation

Panel Connections

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Connections – Aerial View

Dip Switch

Jumpers

1

3

2

4

5

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Control Board

15CAT5

Ethernet Cable

Dipswitches

Jumpers2

3 Output Relay (Lock) 4Reader(s)

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Installation

Dip Switches & Jumpers

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

1 – Dip Switch Settings – Address 1/Gateway

NOTE: The gateway is always the first panel that makes the communications connection to PC

(Default Settings)

1

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

2 - Jumper Settings – PoE Power

2

These jumpers are specifically for lock power and DO NOT affect power used to power the

panel. Setting these jumpers tells output relay 1 & 2 if the relay should be NO or NC and to use either PoE or an external power source for lock power.

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Installation

Door Locks, Readers and Power

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

3 - Lock Connections – PoE

(from panel)

3Note: 18/2 Twisted Shielded cable for

up to 500’

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

3 - Lock Connections - External Power Supply

External Power

2

3

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

4 - Reader Connections

4

Note: 18/6Twisted Shielded cable for up to 500’

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

5 - Power & Communications

5

PoE Injector

• PoE injector (800mA to 900mA)• The board consumes 400mA

which leaves 450mA for other devices.

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Control Board Startup LED’s

1 PoEPower LED

2Run LED

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Installation

Panel Communications

Beyond a Single Panel

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

More then 3 NetAXS-123 Panels in Web ModeFIRST panel is always the

GATEWAY panel

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

`

Gateway Panel Plus Up to 30

More Downstream

Control Panels

Up to 64 Additional

Outputs per Control Panel

Up to 64 Additional Inputs per

Control Panel

`

Remote Web Browser

NX4L1 or

NX4S1

(Downstream mode)

World Wide WebLAN/WAN

VPN

Remote Web Browser

NetAXS-123

(Downstream mode)

NetAXS-123

(Gateway mode)

NetAXS-123 and NetAXS-4 in Web Mode

32

GATEWAY panelMUST be a NetAXS-123

Honeywell Proprietary

HoneywellAccess.comà

NetAXS-123_121211

Host Mode with WINPAKRS-485 CommunicationsSerial Communications

Ethernet CommunicationsRS-485 Communications

33

NetAXS-123Gateway

NetAXS-123Gateway

Recommended