Next Generation Security Solutions Fault Tolerant powered by Hydra January 2013

Preview:

Citation preview

Next Generation Security Solutions

Fault Tolerant powered by HydraJanuary 2013

Introducing:The Next Logical Evolution of Systems…

Virtual Point Architecture

Fault Tolerance Architecture

Is a means of System Recovery utilizing “Automated System Reconfiguration” provided through Dynamic Network Architecture (DNA) with little or no impact on system security or operations upon a failure within any of the components within the system.

PCSC - Hydra Protocol

• Utilizes “Authentication” Protocol• Peer to Peer Communication Protocol • Dynamic Communication Architecture• Communication Manager for FTCs, DDMs and SDMs• Ability to Quickly Detect “communication failure”• Automatically “Re-Route” DDM/SDM to “Alternate” FTCs• Host to FTC Data Synchronization• FTC to FTC Data Synchronization• FTC to DDM/SDM System Parameter Synchronization• Automated Firmware Validation and Updates for FTC,

DDM and SDM

FTC 1

LAN

Door Lock

Card Reader

NXG System

Dual Door Module 1

Door Status

REXLAN

Door Lock

DDM’s 2 through “n”

Door Status

REX

FTC 2

Hydra Protocol

Hydra Protocol — FTC Auto Recover

NXG SystemFTC 1

LAN

Door Lock

Card ReaderDDM 1

Door Status

REXLAN

Door Lock

DDMs 2 through “n”

Door Status

REX

FTC 2

Hydra System Recovery After Failure

FTC 1

LAN

Door Lock

Card Reader

NXG System

DDM 1

Door Status

REXLAN

Door Lock

DDM 2 through “n”

Door Status

REX

FTC 2

Hydra Recovery and Synchronization

FTC 1

LAN

Door Lock

Card Reader

NXG System

DDM 1

Door Status

REXLAN

Door Lock

DDM 2 through “n”

Door Status

REX

FTC 2

Hydra FTC2 Updated - System Operational

FTC 1

LAN

Door Lock

Card Reader

NXG System

DDM 1

Door Status

REXLAN

Door Lock

DDM 2 through “n”

Door Status

REX

FTC 2

FTC Status Display Optional - VFD (Vacuum Fluorescent Display) FTC Number at top FTC-DDM-SDM # – Scrolling Status Status (where X = Controller Number)

+X+ Requesting AssignmentX? Not in Initial Assignment List-X- Deleted from FTC monitoring ListX+ Added to FTC monitoring listX Controller Communication Status Okay . No Response from Nodes

New FTC Features• All the Features of IQ series• 12 AG per Cardholder• Stale Cards• Escort Required by Reader• 12 or 24 Digit Card Numbers• Card Activation & Deactivation by Date and

Time (hh:mm)• Global I/O within Clique• Global Entry/Exit within Clique• HSPD Compliant (PIV, TWIC, etc.)

Rack Mount FTCs

Typical FTC Installation

WAN

Work Station

Rack Mount FTCs

FTC

Host System

DDM/SDM

Enterprise Topology

Primary DDM and FTCs at Remote Site

Backup FTCs at Remote Site

Management Center

WAN

Questions?

Recommended