LDS-104-032205 6096 08.00
Page 1 of 401 June 2019
ENCL
OSE
D 1
0-15
HP
SCRO
LL
ISO
1.2
.0 S
YSTE
M
BeaconMedæs • 1059 Paragon Way, Rock Hill, SC 29730 • Phone: (803) 817-5600 • Fax: (803) 817-5750 • www.beaconmedaes.com
Oil-Free Scroll Air Compressor with Enclosure, Graphic Controller,
Loose Desiccant Dryer and Receiver Tank (10-15 Hp)SPECIFICATION
Enclosed Scroll CompressorThe oil-free scroll air compressor package is fl oor mounted and enclosed in a steel, sound-insulated canopy. The compressor is designed and supplied as a complete package with all necessary equipment, including but not limited to the following components:
• Inlet fi lter• Two air compressor elements• Two drive motors• Aftercooler• Starter and regulation system• Control systemAll components are mounted within a common six-sided low sound enclosure with solid base frame.
The enclosed scroll package provides air quality that qualifi es to be in the category “Class 0” in terms of oil content as defi ned by standard ISO 8573-1:2001 Part 1.
Compressor UnitCompressor Module: The compressor package is made up of two compressor modules, each consisting of a compressor element belt driven by an electric motor, and a radial fan mounted on the drive shaft of the compressor element. Each module is equipped with a temperature sensor to monitor the element housing temperature.
Compression Element: Each compressor element consists of a fi xed scroll housing and an orbiting scroll rotor. The element and housing are pressure die cast aluminum. The crankshaft and pulley are cast iron. The element is V-belt driven using belts with ZPZ profi le. Bolts for adjusting belt tension are easily accessible via removable panels.
Drive Motor: Each compressor module is belt driven by a totally enclosed and air cooled IP55 Class F motor, complying with IE3 Premium effi ciency standards for optimum performance and reliability. The motor bearings are greased for life and do not require special attention.
Starter: Each compressor is factory equipped with a direct on line starter. The starter is mounted and wired within the UL listed compressor control cubicle.
Cooling System: Each compressor element is equipped with a radial fan mounted as part of the element to generate cooling air across the element. The compressor package is fi tted with an aluminum block aftercooler for cooling of the compressed air. The cooling system includes a fan, driven by an electric motor, to generate cooling air for the aftercooler.
Regulation System: The compressor regulation system keeps the net pressure between programmable limits by automatically starting and stopping the compressor modules.
Compressor Control: The compressor package has a microprocessor controller with advanced graphics, capable of controlling and monitoring the modules. The unique Variable Air Delivery control system automatically starts and stops the compressor modules to exactly match the air demand. The controller distributes the running time evenly among the compressor modules by selecting the module with the lowest hours and starting that one fi rst and stopping the unit with the most run hours fi rst when applicable. The controller prevents simultaneous stopping and starting of the individual modules.
The microprocessor allows for programming of two pressure bands for loading and unloading. Time based start/stop and changeover for net pressure is programmable. The compressor is equipped with auxiliary contacts for external indication of run status, automatic or manual run control, general warning and general shutdown conditions.
The control system has the capability to control and monitor the following functions:
• Delivery air pressure• Element outlet temperature• Compressor status• Motor overload status• Delivery air temperature• Running hours• Regulator hours• Ambient temperatureCompressor Protection: The microprocessor provides service requirement indication, warning and shutdown indication and alarms. Additional protective functions inlcude emergency stop, element outlet temperature, drive overload, service warnings, and ambient temperature warning and shutdown.
Inlet Air FilterA paper cartridge type fi lter is provided. The fi lter has a rated effi ciency of SAE fi ne. The fi lter removes 98% of all dust particles greater than 1 micron, 99.5% of particles greater than 2 microns and 99.9% of particles greater than 3 microns in size. The inlet fi lter is factory installed.
Compressor EnclosureThe compressor module is enclosed in a steel, sound-insulated canopy with removable panels to provide access for maintenance. The sound insulating material is a fl ame retardant polyurethane.
LDS-104-032205 6096 08.00
Page 2 of 401 June 2019
Loose Desiccant Dryer AssemblyLoose dryer assembly consists of a twin tower, heatless regenerative desiccant dryer, and one prefi lter.
• Dryer sized to match compressor capacity• Capable of producing -40°C/-40°F pressure dew point• Spring loaded, anodized aluminum desiccant cartridges for
easy service• Optimized purge consumption with nozzle kit to adapt purge
to inlet pressure• Wall mounting kit• PD+ high effi ciency coalescing fi lter to remove solid particles,
liquid water and oil aerosol. Total mass effi ciency 0.01 μm 99.99%.
Loose Prefi lter AssemblyDD+ coalescing fi lter for general purpose protection, removing solid particles, liquid water adn oil aerosol. Total mass effi ciency 0.01μm 99.93%.
Loose Air Receiver Tank AssemblyCorrosion resistent, ASME Coded, National Board Certifi ed
vertical air receiver rated for minimum 200 psig design pressure. The air receiver assembly includes:
• Zero Loss electronic drain valve, liquid level gauge glass, safety relief valve, and manual drain valve
• Piped 3-valve bypass assembly with fl ange-fi tted valves• Pressure gauge with isolation valve
Loose Accessory KitPDp+ Filter: High effi ciency particle fi lter for dust protection, with total mass effi ciency 0.01 μm 99.99%.
Compressor Vibration Isolation Pads: Elasto-Rib Damper furnished with a load distributing steel plate permanently bonded to the Elasto-Rib pad.
Discharge Flex Hose: Flexible metal hose connector with male NPT thread. Corrugated tubing inner hose and heavy-woven braid outer sheath, made of non-corrosive stainless steel.
Regulator with Gauge: 1” NPT 0-160 psig regulator, balanced valve design, non-rising pressure adjusting dial, piston operated.
Notes: 1. Unit performance measured according to ISO 1217, Annex C, latest edition. Reference conditions: Absolute inlet pressure 14.5 psig; Intake air temperature 68°F. Capacity FAD does not include purge losses, approximately 15%.
2. Noise level measured at a distance of 1m according to Pneurop/Cagi PN8NTC2 test code.3. Air Quality measured according to ISO 8573-1. Air quality applicable only with all components assembled, see Scroll
Compressor Package Part Numbers.4. System capacity is compressor capacity less 15% for dryer purge/losses.
Scroll Compressor Package Specifi cations
System Model No. HP
Compressor Working Pressure
Compressor Capacity
FAD1Compressor Noise Level2
Compressor FLA
Air Quality3
Regulated Delivery Pressure
System Capacity4230V 460V
LES10+145B-DD-80V-120 10 141.4 23.9 63 38.3 1-2-0 115 psi 20.8
LES10+145C-DD-80V-120 10 141.4 23.9 63 19.1 1-2-0 115 psi 20.8
LES15+145B-DD-120V-120 15 141.4 31.8 63 53.8 1-2-0 115 psi 27.7
LES15+145C-DD-120V-120 15 141.4 31.8 63 24.3 1-2-0 115 psi 27.7
Scroll Compressor Package Part Numbers
System Model No. Voltage Compressor
Dryer Prefi lter
(DD+)Dryer
Assembly
Dry Receiver
Tank Accessory Kit Air Quality
LES10+145B-DD-80V-120 230/3/60LES10+145B-ND
8153606580 DD20+
2205609605
CD10
8102320184/8092345878/8092261810
80G
4107007949
Filter/Flex Hose/Vibration Pads/
Regulator
2205609606
1-2-0
LES10+145C-DD-80V-120 460/3/60LES10+145C-ND
8153606606
LES15+145B-DD-120V-120 230/3/60LES15+145B-ND
8153606622 DD20+
2205609605
CD12
8102320192/8092345886/8092261810
120G
4107007950
Filter/Flex Hose/Vibration Pads/
Regulator
2205609606
1-2-0
LES15+145C-DD-120V-120 460/3/60LES15+145C-ND
8153606648
LDS-104-032205 6096 08.00
Page 3 of 401 June 2019
CompressorCenter of Gravity
WeightL W HLES10+ 33.2” 12.2” 18.7” 821
LES15+ 34.2” 12.5” 17.4” 922
Dryer A B CWeight
(lbs)LES10+ / CD10 32.7” 34.4” 35.0” 55.1
LES15+ / CD12 38.2” 40.0” 40.6” 63.9
36.9
"
COMPRESSED AIR OUTLET G 1”F
5.1"
10.3
"17
.7"
6.8"
4.6"
11.4"5.7" 11.4" 5.1"
48.4
"
64.1"ELECTRIC CABLEPASSAGE M52(F)
AUTOMATIC DRAIN TUBE Ø0.31”
AMBIENT SENSOR
MANUAL DRAING 1/8”F
VIEW A
3.3”
(4X)
20"
4.7"
3.9"
41.7
"
3.7"
29.3
"
1.4"(2X)
20.1
"
W
6.8"
29.5"
A
L
7.5"
3"
1.8"
7.9"(4X) 31.2(2X)"H
COOLING AIR OUTLET OF AFTERCOOLER
0.6”
(4X)8.3"(2X)
CABINET VENTILATION
COOLING AIR OUTLET OF COMPRESSOR
1"
11.9"
COOLING AIR INLET OF AFTERCOOLER
COOLING AIR INLET OF COMPRESSOR AND CABINET
8.9"
0.2"
12"
17.2
"
22.5" 8"20.4" 11.7"
0.7"
5.1"
1"
16"*
VALVE ROTATION
11.4"
10"
7.9"
8"
11.4" 5.1 0.7"
Compressor Dimensions - LES10 / LES15
Dryer Dimensions - CD10 / CD12
BeaconMedæs1059 Paragon WayRock Hill, SC 29730Phone: (803) 817-5600Fax: (803) 817-5750www.beaconmedaes.com
LDS-104-032205 6096 08.00
Page 4 of 401 June 2019
Receiver Tank WeightLES10+ / 80G 220 LBS
LES15+ / 120G 360 LBS
32.8"/ 37.2”
71.1"/ 77.5”
59.0"/ 65.0” 4.6"/ 6.4”
20.5"/ 27.9”
15.0"/ 21.0”
Ø20.0"/ Ø24.0”
3/4” / 1” NPT OUTLET
ZERO LOSS AUTOMATIC DRAIN VALVE WITH
ISOLATION VALVE
Ø0.38 HOSE BARB
1/4” NPT (PLUGGED)
3/4"/ 1” NPT INLET
MANUAL DRAIN VALVE
LIQUID LEVEL SIGHT GLASS
Receiver Dimensions - 80G / 120G
Recommended