Pediatric HeMOcONceNtratOr
DHF0.2
KiDS
LEADING THE FIELD OF PEDIATRIC PERFUSION FOR OVER 25 YEARS
At Sorin Group, we share your commitment to children. We are committed to providing the very best perfusion products to meet your specific pediatric perfusion needs. The Dideco DHFO.2 Pediatric Hemoconcentrator was designed with your smallest patients in mind.
Biocompatible polyethersulfane high-flux fiber enables •very high ultrafiltration with very low priming volume
Rinseless, requires no flushing •
Use for standard hemoconcentration or •Modified Ultra Filtration (MUF)
Available in stock and custom tubing sets •to meet your pediatric perfusion needs
CP_Dideco_DHF0.2_DS.indd 1 10/23/09 6:41:38 AM
Surface area (m2) .25Fiber type Polyethersulfone Internal diameter (µm) 200 Wall thickness (µm) 30Priming volume (mL) 30 Max. blood flow rate (mL/min) 500Min-max pressure drop (mmHg) 50-150Fiber material PolyethersulfoneDimensions Length (mm) 145 Diameter (mm) 55Weight (g) 98Maximum transmembrane pressure (TMP) 500mmHg
Technical Features
Creatinine Albumin
MOLECULAR WEIGHT
SIEVING COEFFICIENTS(QB= 300 ml/min - QF= 100 ml/min - in vitro)
Inulin MyglobinB12Urea
Conventionaldialysis membrane
Naturalkidney
Polyethersulfone
(60)
100
1.0
S
0.5
1000 10000
(113) (1355) (5200) (17500) (65000)
120
TMP (mmHg)
UF
(mL/
min
)ULTRAFILTRATION RATE
500450400350300250200150100
100
80
60
40
20
0
DHF 0.6
120
TMP (mmHg)
UF
(mL/
min
)
ULTRAFILTRATION RATE
500450400350300250200150100
100
80
60
40
20
0
DHF 0.2
Qb=300mL/min
Qb=300mL/min
Qb=500mL/min
Qb=500mL/min
Qb=100mL/min
Qb=100mL/min
Sorin Group USa, inc.
14401 W. 65th Way, arvada, cO 80004
800.221.7943 • 303.467.6525 fax
www.soringroup-usa.com
Caution: Federal law (USA) restricts this device to sale by or on the order of a physician.
Part number 306600050 rev c (10/09) ©2009 Sorin Group USa, inc.
Efficient: A high molecular weight sieving coefficient allows removal of larger molecules without the loss of key blood proteins.
Small: Only 30mL priming volume.
Safe: Biocompatible polyethersulfone fiber was specifically designed for blood contact.
Simple: Rinseless, the DHFO.2 does not require flushing, which will save you time and money.
Custom: Available in stock and custom perfusion sets, with 1/8”, 3/16” or 1/4” blood inlet and outlet to meet your specific pediatric perfusion needs.
this data sheet was printed on recycled paper.
Catalog Number Product Case Quantity
020115801 HC Waste Bag 10/case020497701 DHF0.2 1/4” TBG 12”, CONN 8/case09017 Hemoconcentrator Bracket 1/case
Order Guide
CP_Dideco_DHF0.2_DS.indd 2 10/23/09 6:41:41 AM
Recommended