PROPOSED NEW 1 / SH.AR-111.D 1 / SH.AR-111.D … · sewer line proposed new sewer connection...

Preview:

Citation preview

2

AR-514.C

4

AR-506.A

2

AR-513.C

4

AR-514.C

SLO

PIN

G L

AN

DS

CA

PIN

G

WATERFALL EDGE

PLANTERWITH

SEATING

PLANTERWITH

SEATING

WATERFEATURE

PLANTERWITH

SEATING

PLANTERWITH

SEATING

PLANTER

PLANTER

PLA

NTER

PLA

NTER

PLA

NTER

PLA

NTER

SEATING

SEATING

PLANTER

PLA

NTER

LASER-CUT METAL SCREEN

UP

6.0

7.0

8.0 7.0

BA

SE

ME

NT

EN

TR

Y R

AM

P

POOL

LAWN

POOLPAVILLION

MULTI-PURPOSEPAVILLION

MULTI-PURPOSEPAVILLION

MULTI-PURPOSEPAVILLION

MULTI-PURPOSEPAVILLION

MALE

FEMALE

MULTI-PURPOSEPAVILLION

TERRACED PLANTING

TERRACED PLANTING

TRANSFORMER

RL 9.95

RAMP 1:14

PAVINGPATTERNS

RL 8.72

RL 8.40

COVERED W

ALK

WAY

RL 6.95

RL 6.20

RL 7.95

1.8m MinACOUSTIC WALL

LOADING BAY

COVEREDWALKWAY

COVERED WALKWAY

POOLPAVILLION

RL 5.95

RL 8.80

RL 8.60

RL 8.72 RL 8.40

1:2

0

UPPERLAWN

LOWERLAWN

LAWN

1:20

RL 9.95

SEATING

SEATING

WATERFALL EDGE

SHALLOWWATERFEATURE

STAGE-2TURFED AREA OVERBASEMENT BELOW

7.0

1.8m ACOUSTIC FENCE

DOWN TOMEZZANINESTORAGE

BBQ

NEW STORMWATER PIT

PROPOSED NEWSEWER LINE

PROPOSED NEWSEWER CONNECTION

PROPOSED NEWSTORMWATEREASEMENT

PROPOSED NEWSTORMWATER PIT

PROPOSED NEWSEWER MANHOLE

RETAINING WALL. SURFACEGRADES IN EASEMENT TOALLOW OVERLAND FLOW

SURFACE LEVEL GRADES DOWN

SURFACE LEVEL GRADES DOWN

SURFACE RL 7.45 SURFACE RL 7.52

7 7

8 8

9 9

1

AR-304.C

3

AR-514.C

2

AR-512.C

3

AR-512.C

P.1

P.2

P.3

P.4

P.5

P.6

P.7

P.8

P.9

SSL. 8.400

SSL. 8.400

SSL. 8.400

SSL. 9.950

RL 8.95

SSL. 8.400

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

1.8m MinACOUSTIC WALL

3

AR-509.A

G.206

Dt.6

G.207

Dt.6

G.28

Dt.3

2

AR-302.C

2

AR-302.C

1

AR-302.C

1

AR-302.C

2

AR-304.C

2

AR-304.C

3

AR-302.C

3

AR-302.C

6

AR-502.A

12

AR-502.A

G.206

Dt.6

6

AR-512.C

4

AR-512.C

5

AR-512.C

7

AR-512.C

3

AR-513.C

5

AR-509.A

2X LAP LANES

HOSETAP

HOSETAP

HOSETAP

EQUIPMENTROOM

7

AR-513.C

EQ

EQ

250mmRAISED

PLATFORM

250mmRAISED

PLATFORM

*FW

POOL PUMPROOM

G.208

Dt.20

G.209

Dt.20

SAUNA/1 SH.AR-111.D/1 SH.AR-111.D

606060 60

DP

DP

DP

DP

DP

DP

DP

WEST EAST

SOUTH

2.5m

5mA1

1:100A3

1:2001m

10m

5m

.5m

FIRE MAINS INCLUDING BOOSTER AND /OR PUMPS.REQUIRED FLOW AND TRESSURE TEST 5L/s @ 70kpa (BUILDING PUMP) AND 10 L/s@700 lpa (BOOSTED).THE QFES REQUIRE BLOCK PLANS FOR HYDRANT AND BOOSTER CABINETS.ZONE DIAGRAMS FOR FIRE ALARM SYSTEMS TO BE:- ETCHED, ENGRAVED OR PRINTED ON METAL OR PLASTIC THAT IS SUITABLE FORINSTALLATION IN AN OUTDOOR LOCATION, (PAPER ENCLOSED WITHIN A PLASTICOR LAMINATED COVER IS NOT ACCEPTABLE).- A MINIMUN OD A3 SIZE- MECHANICALLY SECURED IN THE REQUIRED LOCATION.- CORRECTLY ORIENTATED TO THE BUILDING/SITE AND,- MEET ALL OF THE OTHER REQUIREMENTS OF THE AS. 2419.1-2005 INCLUDING THEFEATURES IDENTIFIED ON THE PLAN.PUMP ROOM WILL REQUIRE ADEQUATE VENTILATION FOR THE ASPIRATION ANDCOOLING OF THE PUMP DRIVERS.

FIRE DETECTION AND ALARM SYSTEMS, (SMOKE ALARMS).

ACHEIVEMENT OF A SPECIFIED PERFORMANCE OF DETECTION AND ALARMSYSTEMSSUITABILITY OF NOMINAL TYPES OF DETECTION IN ALL AREAS, AND THE LICATIONOF MANUAL CALL POINTS.

CERTIFICATION IS REQUIRED FOR EACH SPECIAL FIRE SERVICE, THIS WILL BEREQUIRED PRIOR TO OR AT THE TIME OF INSPECTION.

QFES COMLIANT REQUIREMENTS.

WET AREA BULKHEADS (RW-CTR 40)350mm CEAR SPACE.ALL FLOOR PENETRATION TO HAVE FIRE COLLARS.REFER TO BORAL SYSTEMS 'SECTION H' TABLE 17FOR CORRECT SERVICES SEPERATIONS

STD BULKHEADS (RW-CTR 25)

CEAR CEILING SPACE AS INICATED ON REFLECTEDCEILING PLAN.ALL FLOOR PENETRATION TO HAVE FIRE COLLARSINSTALLED TO MANUFACTURES DETAILSREFER TO BORAL SYSTEMS 'SECTION H' TABLE 17FOR CORRECT SERVICES SEPERATIONS.

STD UNIT ROOF SOFIT.CEILING TO BE PLASTERBOARD ON FURRINGCHANNEL

SERVICE SHAFTS. (RW-CTR 40)REFER TO BORAL SYSTEMS 'SECTION H' TABLE 17FOR CORRECT SERVICES SEPERATIONS

BV Basement VentCD Clothes DryerCP Chrome PolishedCT Ceramic TileDP Down PipeDPS Downpipe-SpreaderDSS Door Smoke SealDW Dish WasherH? Handrail TypeFH Fire HoseFHR Fire Hose ReelFW Floor WasteWC Toilet PanSi Sink WasteOV OvenPC Powder Coated FinishPSD Patio Sliding DoorPG Pool GateRef RefridgeratorSF Stone FinishSS Stainless SteelWM Washing MachineLT Laundry TubWS Wheel StopW? Wall TypeTI Tactile IndicatorsDVS Ducted Vacuum SystemVB Vanityc1 Column TypeTC1 Tapered Column

ACN:110893493 6/70 BAY TCE. WYNNUM QLD 4178

P.O. BOX 5129 MANLY QLD 4179 E-MAIL: enquiries@ttarchitects.com.au TELEPHONE: (07)3348 3727

MOBILE: 0412 087 196

PROJECT

These drawings are the copyright of THINK TANKArchitects and are not to be reproduced in any waywithout the consent of THINK TANK Architects

CLIENT

ADDRESS

ARCHITECT

DATE

DRAWING NAME

SCALE

DWG NO. REVISION

DRAWN BY CHECKED BY

MICHAEL JULLYAN

AT A1

C:\Users\garydeane.TTARCHITECTS\Documents\REVITLOCAL FILE\TOONDAH OUTLOOKBA1_MichaelJullyan8412.rvt

As indicated

WHARF,MIDDLE & SHORE ST EAST

TOONDAH OUTLOOK

ANDERSON FAMILY TRUST

GD

GROUND SOUTH

AR-113.D

25-08-17

36-14

#4 BA1 ISSUE

MJ

@A1 1 : 100

2C GROUND SOUTH1

NORTH

REVISION HISTORY

REV DESCRIPTION DATE3 Rev-C BA 1 PRELIM 11-08-17

1 Rev-A BA PRELIM 12-05-17

2 Rev-B BA PRELIM UPDATES 25-07-17

4 BA1 ISSUE 25-08-17

Recommended