View
240
Download
2
Category
Preview:
Citation preview
Our technology. Your success.Pumps ■ Valves ■ Service
Pumps and Automation 2015
Type Series Index
Type Series Index
2
Type Series IndexAmacan K 52Amacan P 52Amacan S 52Amacontrol 70Ama‐Drainer 4../5.. 47Ama‐Drainer 80, 100 47Ama‐Drainer N 301 – 358 46Ama‐Drainer‐Box 48Ama‐Drainer‐Box Mini 48AmaDS³ 48Amajet 53Amaline 53Amamix 53Ama‐Porter CK Pump Station 49Ama‐Porter F / S 47Amaprop 53Amarex KRT 51Amarex KRT, dry‐installed, jacket‐cooled 51Amarex KRT, wet‐/dry‐installed, withenergy‐saving motor 51Amarex N 51Amarex N CK Pump Station 49Amarex N S32 51API series (Nikkiso‐KSB) 38
BEV 60Beveron 65BOA‐Systronic 70
Calio 29Calio S 29Calio Therm S 28Cervomatic EDP.2 69CHTA / CHTC / CHTD 63CHTR 38CINCP / CINCN 39CK 800 Pump Station 49Compacta 49Controlmatic E 69Controlmatic E.2 69CPKN 34CTN 38
DN (Nikkiso‐KSB) 37DU / EU 68
Ecochem Non‐Seal HN, HP, HT, HS 36EDS 68Etabloc 31Etabloc SYT 33Etachrom BC 31Etachrom NC 32Etaline 30Etaline SYT 33Etaline Z 30Etaline‐R 30Etanorm 31Etanorm SYT / RSY 33Etanorm V 32Etanorm‐R 31Etaprime B / BN 58Etaprime L 58Etaseco / Etaseco‐I 35Etaseco RVP 35Eva‐Clean 48Evamatic‐Box N 50
FGD 56Filtra N 42
HGB / HGC / HGD 63HGM 63HGM‐RO 67HK (Nikkiso‐KSB) 36HN (Nikkiso‐KSB) 36HPH 32HPK 32HPK‐L 32HT (Nikkiso‐KSB) 36HVF 57HX (Nikkiso‐KSB) 34HY (Nikkiso‐KSB) 34Hya‐Compact K 43
Hya‐Compact VP 43Hya‐Duo D FL 43Hya‐Duo D FL Compact 43Hya‐Eco VP 44Hyamat K 44Hyamat SVP 44Hyamat V 44Hya‐Rain / Hya‐Rain N 40Hya‐Rain Eco 40Hya‐Solo D 42Hya‐Solo D FL 42Hya‐Solo D FL Compact 43Hya‐Solo DSV 42Hya‐Solo EV 42hyatronic N 70
ILN / ILNE / ILNS 30ILNC / ILNCE / ILNCS 30INVCP / INVCN 39Ixo N 41Ixo‐Pro 41
Kondensat‐Lift 49KSB SuPremE 27KWP / KWP‐Bloc 54
LCC‐M 55LCC‐R 55LCV 56LevelControl Basic 2 69LHD 56LSA‐S 55LUV / LUVA 64LUV Nuclear 66
Magnochem 35Magnochem‐Bloc 35MDX 57Mega 56MegaCPK 34MHD 56mini‐Compacta 48MK / MKY 47Movitec 60Movitec VCI 60Movitec VME 41Multi Eco 40Multi Eco‐Pro 40Multi Eco‐Top 41Multitec / Multitec‐RO 61MZ 58
Omega 61
PSR 66PumpDrive 2 / PumpDrive 2 Eco 27PumpMeter 27
RC / RCV 68RDLO 61RDLP 61RER 65RHD 66RHM 66RHR 67Rio‐Eco N 29Rio‐Eco Therm N 28Rio‐Eco Z N 29Riotherm 28Rio‐Therm N 28Rotex 47RPH 37RPHb 37RPHmdp 38RPH‐RO 67RPH‐V 37RSR 65RUV 65RVM 66RVR 67RWCP / RWCN 39
S 100D 59
Salino Pressure Center 67Secochem Ex 35Secochem Ex K 36Set 100 41Sewabloc 54Sewatec 54SEZ / SEZT / PHZ / PNZ 64SNW / PNW 64SPY 65SRP 50Superbloc SBC.B 44Surpress Eco SE.2.B 45Surpress Eco SE.2.B VP 45Surpress Feu SFE 46Surpress SP 46Surpress SP VP 46Surpressbloc SB 46Surpresschrom SIC.2 45Surpresschrom SIC.2 SVP 45Surpresschrom SIC.2 V 45
TBC 55
UPA 100C 59UPA 150C 59UPA 200, 200B, 250C 59UPA 300, 350 59UPA Control 69UPZ, BSX‐BSF 60
Vitacast 62Vitachrom 62Vitalobe 63Vitaprime 62Vitastage 62VN (Nikkiso‐KSB) 37
WBC 55WKTB 64WKTR 39
YNK 64YNKR 38
ZW 57
Introduction
Introduction
3
Our tradition:Competence since 1871
We have supplied generations of customers worldwide with pumps, valves, automation products and services. A company with that kind of experience knows that success is a process based on a stream of innovations. A process made possible by a close working alliance between developer and user, between production and practice.
Partners achieve more together.
We do everything possible to ensure that our customers
always have access to the ideal product and system solution.
KSB is a loyal partner. And a strong one:
■■ Over 140 years’ experience
■■ Present in more than 100 countries
■■ More than 16,000 employees
■■ More than 160 service centres worldwide
■■ Approximately 3,000 service specialists
Introduction
Introduction
4
Our spare parts and services:Dependability at your call
We tailor our services to enable new ways of indi-
vidually optimising our products. They underscore
our far-reaching sense of customer responsibility.
That commitment starts before any orders – for
example with sound advice on financing options.
And it goes far beyond product arrival. A depend-
able partnership with KSB lasts for years.
In addition to spare parts, we offer our customers
a plethora of services around pumps, valves,
and other rotating equipment – also for non-KSB
products:
■■ Technical consultancy
■■ Services provided on-site and in our service centres
■■ Maintenance inspection management
■■ Reverse engineering / retrofit
■■ TPM® Total Pump Management
■■ SES System Efficiency Services
Which is how we secure the long-term value of our
customers’ facilities.
Ready where you are. KSB runs more than 160
service centres around the world. Some 3,000
highly trained KSB specialists are on call to install,
commission and maintain your equipment. So you
can plan for a future free of unwanted surprises.
And we also provide on-site training sessions.
They ensure that operators can use KSB pumps and
valves efficiently and profitably, day in, day out.
Introduction
Introduction
5
Introduction
Introduction
6
DemanD-Driven operationOptimised control systems like PumpDrive continuously match pump output to system requirements.
HigH-efficiency DrivesOur high-efficiency motors even exceed today’s standards.
HigH-efficiency pumps & valves Top pump and valve performance with minimum loss – all thanks to 140 years of innovation and expertise.
selectionYour KSB partner or KSB EasySelect will help you find exactly the right pumps and valves.
system analysis Our experts analyse your system and show where you can save energy – with SES System Efficiency Service or PumpMeter.
saving energy has never been so easy
The clever interaction between the five modules of FluidFuture®, KSB‘s energy efficiency concept, ensures maximum efficiency for your pump system. Following the introduction of KSB‘s SuPremE® motors, FluidFuture® now features a new generation of motors that enable you to run your system more leanly than with any other pump drive.
fluidfuture® – five modules for greater efficiency
KSB uses the energy efficiency concept FluidFuture® to assess
the entire hydraulic system. The objective: to increase overall
efficiency. Following a comprehensive system analysis,
KSB selects high-efficiency pumps, valves and motors to optimise
the system and ensure maximum efficiency with demand-driven
operation. This means maximum energy savings for you.
perfect combination
Combining high-efficiency components reduces energy
consumption and saves you real money. The interaction of
KSB SuPremE® motor, PumpDrive variable speed system and
PumpMeter is a case in point. While the operating pressure is
continually measured by the intelligent PumpMeter pressure
sensor, PumpDrive ensures it is adjusted to the actual demand.
Especially in the low-flow range this plays an important role.
It also reduces energy costs and wear on components. The savings
achieved are further maximised by the exceptional efficiency of
the KSB SuPremE® motor.
General Information
General Information
7
FluidFuture®FluidFuture® is our comprehensive energy efficiency concept for your entire hydraulic system. Itsaim is to improve your plant’s efficiency. To make that reality, we’ve developed five interlockingmodules. Together they enable us to identify and achieve savings right through the life cycle ofyour pumps and valves. You can maximise savings by optimising the overall efficiency of your plant,making it run more cost‐effectively, efficiently and longer. FluidFuture® benefits your company, ourenvironment and generations to come. More information at www.ksb.de/fluidfuture
ErPWith the start of 2015 the new, stricter minimum efficiency values of the ErP regulations havebecome effective. From now on, only pumps and motors which satisfy the energy efficiencyrequirements of the European Union's ErP Directive may be placed on the market. For KSB'sproducts this is child's play. They are so efficient, many already exceed the values required from2015 – some even those applicable from 2017 as per the ErP regulations.
ProductsNot all depicted products are available for sale in every country. Products only available in individual regionsare indicated accordingly. Please contact your sales representative for details.
Trademark rightsAll trademarks or company logos shown in the catalogue are protected by trademark rights owned by KSBAktiengesellschaft and/or a KSB Group company. The absence of the "®" symbol should not be interpreted tomean that the term is not a registered trademark.
Product Portfolio
Product Portfolio
8
Pumps
Design / Application Type series Page Flu
idFu
ture
ErP
Fact
ory
‐au
tom
ated
Au
tom
atio
nav
aila
ble
Wat
er T
ran
spo
rtan
d T
reat
men
t
Ind
ust
ry
Ener
gy
Co
nve
rsio
n
Bu
ildin
gSe
rvic
es
Solid
s Tr
ansp
ort
Circulators / hot water service pumps,fixed speed
Riotherm 28
Drinking water circulators, fixed speed Rio‐Therm N 28
Drinking water circulators, variablespeed
Rio‐Eco Therm N 28
Calio Therm S 28
Circulators, variable speed
Calio S 29
Calio 29
Rio‐Eco N 29
Rio‐Eco Z N 29
In‐line pumps with fixed / variable speeddrive
Etaline 30
Etaline Z 30
Etaline‐R 30
ILN / ILNE / ILNS 30
ILNC / ILNCE / ILNCS 30
Standardised / close‐coupled pumps,fixed / variable speed
Etanorm 31
Etanorm‐R 31
Etabloc 31
Etachrom BC 31
Etachrom NC 32
Etanorm V 32
Hot water pumps
HPK‐L 32
HPH 32
HPK 32
Hot water / thermal oil pumps
Etanorm SYT / RSY 33
Etabloc SYT 33
Etaline SYT 33
Thermal oil pumps with magnetic driveor canned motor
HX (Nikkiso‐KSB) 34
HY (Nikkiso‐KSB) 34
Standardised chemical pumpsMegaCPK 34
CPKN 34
Seal‐less pumps
Magnochem 35
Magnochem‐Bloc 35
Etaseco / Etaseco‐I 35
Etaseco RVP 35
Secochem Ex 35
Secochem Ex K 36
Ecochem Non‐Seal HN 36
Ecochem Non‐Seal HT 36
Ecochem Non‐Seal HP 36
Ecochem Non‐Seal HS 36
HN (Nikkiso‐KSB) 36
HT (Nikkiso‐KSB) 36
HK (Nikkiso‐KSB) 36
VN (Nikkiso‐KSB) 37
DN (Nikkiso‐KSB) 37
Product Portfolio
Product Portfolio
9
Design / Application Type series Page Flu
idFu
ture
ErP
Fact
ory
‐au
tom
ated
Au
tom
atio
nav
aila
ble
Wat
er T
ran
spo
rtan
d T
reat
men
t
Ind
ust
ry
Ener
gy
Co
nve
rsio
n
Bu
ildin
gSe
rvic
es
Solid
s Tr
ansp
ort
Process pumps
RPH 37
RPHb 37
RPH‐V 37
RPHmdp 38
CTN 38
API series (Nikkiso‐KSB) 38
CHTR 38
YNKR 38
CINCP / CINCN 39
INVCP / INVCN 39
RWCP / RWCN 39
WKTR 39
Rainwater harvesting systemsHya‐Rain / Hya‐Rain N 40
Hya‐Rain Eco 40
Domestic water supply systems withautomatic control unit / swimming poolpumps
Multi Eco 40
Multi Eco‐Pro 40
Set 100 41
Multi Eco‐Top 41
Movitec VME 41
Ixo N 41
Ixo‐Pro 41
Filtra N 42
Pressure booster systems
Hya‐Solo EV 42
Hya‐Solo D 42
Hya‐Solo DSV 42
Hya‐Solo D FL 42
Hya‐Duo D FL 43
Hya‐Solo D FL Compact 43
Hya‐Duo D FL Compact 43
Hya‐Compact K 43
Hya‐Compact VP 43
Superbloc SBC.B 44
Surpress Eco SE.2.B 45
Hya‐Eco VP 44
Hyamat K 44
Hyamat V 44
Hyamat SVP 44
Surpress Eco SE.2.B VP 45
Surpresschrom SIC.2 45
Surpresschrom SIC.2 V 45
Surpresschrom SIC.2 SVP 45
Surpressbloc SB 46
Surpress Feu SFE 46
Surpress SP 46
Surpress SP VP 46
Drainage pumps / waste water pumps
Ama‐Drainer N 301 – 358 46
Ama‐Drainer 4.. / 5.. 47
Ama‐Drainer 80, 100 47
Ama‐Porter F / S 47
Rotex 47
MK / MKY 47
Product Portfolio
Product Portfolio
10
Design / Application Type series Page Flu
idFu
ture
ErP
Fact
ory
‐au
tom
ated
Au
tom
atio
nav
aila
ble
Wat
er T
ran
spo
rtan
d T
reat
men
t
Ind
ust
ry
Ener
gy
Co
nve
rsio
n
Bu
ildin
gSe
rvic
es
Solid
s Tr
ansp
ort
Lifting units / pump stations
AmaDS3 48
Ama‐Drainer‐Box 48
Ama‐Drainer‐Box Mini 48
Eva‐Clean 48
mini‐Compacta 48
Compacta 49
Kondensat‐Lift 49
CK 800 Pump Station 49
Ama‐Porter CK Pump Station 49
Amarex N CK Pump Station 49
Evamatic‐Box N 50
SRP 50
Submersible motor pumps
Amarex N 51
Amarex N S 32 51
Amarex KRT 51
Amarex KRT dry‐installed 51
Amarex KRT wet‐/dry‐installed 51
Submersible pumps in discharge tubes
Amacan K 52
Amacan P 52
Amacan S 52
Mixers / agitators / tank cleaning units
Amamix 53
Amaprop 53
Amajet 53
Amaline 53
Pumps for solids‐laden fluids
Sewatec 54
Sewabloc 54
KWP / KWP‐Bloc 54
Slurry pumps
WBC 55
LSA‐S 55
LCC‐M 55
LCC‐R 55
TBC 55
LCV 56
FGD 56
Mega 56
MHD 56
LHD 56
MDX 57
ZW 57
HVF 57
Self‐priming pumps
Etaprime L 58
Etaprime B / BN 58
MZ 58
Submersible borehole pumps
S 100D 59
UPA 100C 59
UPA 150C 59
UPA 200, 200B, 250C 59
UPA 300, 350 59
UPZ, BSX‐BSF 60
Deep‐well turbine pumps BEV 60
High‐pressure pumps, fixed / variablespeed
Movitec 60
Movitec VCI 60
Multitec / Multitec‐RO 61
Axially split pumps
Omega 61
RDLO 61
RDLP 61
Product Portfolio
Product Portfolio
11
Design / Application Type series Page Flu
idFu
ture
ErP
Fact
ory
‐au
tom
ated
Au
tom
atio
nav
aila
ble
Wat
er T
ran
spo
rtan
d T
reat
men
t
Ind
ust
ry
Ener
gy
Co
nve
rsio
n
Bu
ildin
gSe
rvic
es
Solid
s Tr
ansp
ort
Hygienic pumps for the food, beverageand pharmaceutical industries
Vitachrom 62
Vitacast 62
Vitaprime 62
Vitastage 62
Vitalobe 63
Pumps for power station conventionalislands
CHTA / CHTC / CHTD 63
HGB / HGC / HGD 63
HGM 63
YNK 64
LUV / LUVA 64
WKTB 64
SEZ / SEZT / PHZ / PNZ 64
SNW / PNW 64
Beveron 65
SPY 65
Pumps for nuclear power stations
RER 65
RSR 65
RUV 65
PSR 66
RHD 66
LUV Nuclear 66
RHM 66
RVM 66
RHR 67
RVR 67
Pumps and pressure exchangers forseawater desalination by reverse osmosis
RPH‐RO 67
HGM‐RO 67
SALINO Pressure Center 67
Positive displacement pumps RC / RCV 68
Fire‐fighting systemsEDS 68
DU / EU 68
Product Portfolio
Product Portfolio
12
Automation and drives
Design / Application Type series Page Flu
idFu
ture
ErP
Wat
er T
ran
spo
rtan
d T
reat
men
t
Ind
ust
ry
Ener
gy
Co
nve
rsio
n
Bu
ildin
gSe
rvic
es
Solid
s Tr
ansp
ort
Automation and drives KSB SuPremE 27
Control units
Controlmatic E 69
Controlmatic E.2 69
Cervomatic EDP.2 69
LevelControl Basic 2 69
UPA Control 69
hyatronic N 70
Variable speed system PumpDrive 2 / PumpDrive 2 Eco 27
Monitoring and diagnosis PumpMeter 27
Amacontrol 70
Control system BOA‐Systronic 70
Overview of Applications
Overview of Applications
13
Fluids handled
Rio
ther
m
Rio
‐Th
erm
N
Rio
‐Eco
Th
erm
NC
alio
Th
erm
S
Cal
io S
Cal
ioR
io‐E
co N
Rio
‐Eco
Z N
Etal
ine
Etal
ine
ZEt
alin
e‐R
ILN
/ IL
NE
/ ILN
SIL
NC
/ IL
NC
E / I
LNC
S
Etan
orm
/ Et
ano
rm‐R
Etab
loc
Etac
hro
m B
CEt
ach
rom
NC
Etan
orm
V
HPK
‐LH
PHH
PK
Etan
orm
SY
T / R
SYEt
ablo
c SY
T / E
talin
e SY
T
Waste water with faeces
Cir
cula
tors
/ h
ot
wat
er s
ervi
ce p
um
ps,
fix
ed s
pee
d
Dri
nki
ng
wat
er c
ircu
lato
rs, f
ixed
sp
eed
Dri
nki
ng
wat
er c
ircu
lato
rs, v
aria
ble
sp
eed
Cir
cula
tors
, var
iab
le s
pee
d
In‐l
ine
pu
mp
s w
ith
fix
ed /
vari
able
sp
eed
dri
ve
Stan
dar
dis
ed /
clo
se‐c
ou
ple
d p
um
ps,
fix
ed /
vari
able
sp
eed
Ho
t w
ater
pu
mp
s
Ho
t w
ater
/ th
erm
al o
il p
um
ps
Waste water without faecesAggressive liquids
Inorganic liquidsActivated sludge
Brackish waterService water
DistillateSlurries
Explosive liquidsDigested sludge
Solids (ore, sand, gravel, ash)Flammable liquids
River, lake and groundwaterLiquefied gas
Food and beverage productionGas‐containing liquids
Filtered waterHarmful liquids
Toxic liquidsHigh‐temperature hot water
Heating waterHighly aggressive liquids
Industrial service waterCondensate
Corrosive liquidsValuable liquids
FuelsCoolant
Cooling lubricantCooling water
Volatile liquidsFire‐fighting water
SolventsSeawater
OilsOrganic liquids
Pharmaceutical fluidsPolymerising liquids
Rainwater / stormwaterCleaning agents
Raw sludgeLubricants
Waste waterSwimming pool water
BrineFeed water
Dipping paintsDrinking water
Thermal oilHot water
Wash water
Overview of Applications
Overview of Applications
14
Fluids handled
HX
(N
ikki
so‐K
SB)
HY
(N
ikki
so‐K
SB)
Meg
aCPK
CPK
N
Mag
no
chem
Mag
no
chem
‐Blo
cEt
asec
o /
Etas
eco
‐IEt
asec
o R
VP
Seco
chem
Ex
Seco
chem
Ex
KEc
och
em N
on
‐Sea
l HN
Eco
chem
No
n‐S
eal H
TEc
och
em N
on
‐Sea
l HP
Eco
chem
No
n‐S
eal H
SH
N (
Nik
kiso
‐KSB
)H
T (N
ikki
so‐K
SB)
HK
(N
ikki
so‐K
SB)
VN
(N
ikki
so‐K
SB)
DN
(N
ikki
so‐K
SB)
RPH
RPH
bR
PH‐V
RPH
md
pC
TNA
PI s
erie
s (N
ikki
so‐K
SB)
CH
TRY
NK
RC
INC
P / C
INC
NIN
VC
P / I
NV
CN
RW
CP
/ RW
CN
WK
TR
Waste water with faecesTh
erm
al o
il p
um
ps
wit
h m
agn
etic
dri
ve o
r ca
nn
ed m
oto
r
Stan
dar
dis
ed c
hem
ical
pu
mp
s
Seal
‐les
s p
um
ps
Pro
cess
pu
mp
s
Waste water without faecesAggressive liquids
Inorganic liquidsActivated sludge
Brackish waterService water
DistillateSlurries
Explosive liquidsDigested sludge
Solids (ore, sand, gravel, ash)Flammable liquids
River, lake and groundwaterLiquefied gas
Food and beverage productionGas‐containing liquids
Filtered waterHarmful liquids
Toxic liquidsHigh‐temperature hot water
Heating waterHighly aggressive liquids
Industrial service waterCondensate
Corrosive liquidsValuable liquids
FuelsCoolant
Cooling lubricantCooling water
Volatile liquidsFire‐fighting water
SolventsSeawater
OilsOrganic liquids
Pharmaceutical fluidsPolymerising liquids
Rainwater / stormwaterCleaning agents
Raw sludgeLubricants
Waste waterSwimming pool water
BrineFeed water
Dipping paintsDrinking water
Thermal oilHot water
Wash water
Overview of Applications
Overview of Applications
15
Fluids handled
Hya
‐Rai
n /
Hya
‐Rai
n N
Hya
‐Rai
n E
co
Mu
ltiE
coSe
t 10
0M
ult
iEco
‐Pro
Mu
ltiE
co‐T
op
Mo
vite
c V
ME
Ixo
NIx
o P
roFi
ltra
N
Hya
‐So
lo E
VH
ya‐S
olo
DH
ya‐S
olo
DSV
Hya
‐So
lo D
FL
Hya
‐Du
o D
FL
Hya
‐So
lo D
FL
Co
mp
act
Hya
‐Du
o D
FL
Co
mp
act
Hya
‐Co
mp
act
KH
ya‐C
om
pac
t V
PSu
per
blo
c SB
CSu
rpre
ss E
co S
E.2.
BH
ya‐E
co V
PH
yam
at K
Hya
mat
VH
yam
at S
VP
Waste water with faeces
Rai
nw
ater
har
vest
ing
sys
tem
s
Do
mes
tic
wat
er s
up
ply
sys
tem
s w
ith
au
tom
atic
co
ntr
ol u
nit
/ sw
imm
ing
po
ol p
um
ps
Pres
sure
bo
ost
er s
yste
ms
Waste water without faecesAggressive liquids
Inorganic liquidsActivated sludge
Brackish waterService water
DistillateSlurries
Explosive liquidsDigested sludge
Solids (ore, sand, gravel, ash)Flammable liquids
River, lake and groundwaterLiquefied gas
Food and beverage productionGas‐containing liquids
Filtered waterHarmful liquids
Toxic liquidsHigh‐temperature hot water
Heating waterHighly aggressive liquids
Industrial service waterCondensate
Corrosive liquidsValuable liquids
FuelsCoolant
Cooling lubricantCooling water
Volatile liquidsFire‐fighting water
SolventsSeawater
OilsOrganic liquids
Pharmaceutical fluidsPolymerising liquids
Rainwater / stormwaterCleaning agents
Raw sludgeLubricants
Waste waterSwimming pool water
BrineFeed water
Dipping paintsDrinking water
Thermal oilHot water
Wash water
Overview of Applications
Overview of Applications
16
Fluids handled
Surp
ress
Eco
SE.
2.B
VP
Surp
ress
chro
m S
IC.2
Surp
ress
chro
m S
IC.2
VSu
rpre
ssch
rom
SIC
.2 S
VP
Surp
ress
blo
c SB
Surp
ress
Feu
SFE
Surp
ress
SP
Surp
ress
SP
VP
Am
a‐D
rain
er N
301
– 3
58A
ma‐
Dra
iner
4..
/ 5..
Am
a‐D
rain
er 8
0, 1
00A
ma‐
Port
er F
/ S
Ro
tex
MK
/ M
KY
Am
aDS3
Am
a‐D
rain
er‐B
ox
Am
a‐D
rain
er‐B
ox
Min
iEv
a‐C
lean
min
i‐C
om
pac
taC
om
pac
taK
on
den
sat‐
Lift
CK
800
Pu
mp
Sta
tio
nA
ma‐
Port
er C
K P
um
p S
tati
on
Am
arex
N C
K P
um
p S
tati
on
Evam
atic
‐Bo
xSR
P
Am
arex
NA
mar
ex N
S 3
2A
mar
ex K
RT
Am
arex
KR
T d
ry‐i
nst
alle
dA
mar
ex K
RT
wet
‐/d
ry‐i
nst
alle
d
Waste water with faecesPr
essu
re b
oo
ster
sys
tem
s
Dra
inag
e p
um
ps
/ was
te w
ater
pu
mp
s
Lift
ing
un
its
/ pu
mp
sta
tio
ns
Sub
mer
sib
le m
oto
r p
um
ps
Waste water without faecesAggressive liquids
Inorganic liquidsActivated sludge
Brackish waterService water
DistillateSlurries
Explosive liquidsDigested sludge
Solids (ore, sand, gravel, ash)Flammable liquids
River, lake and groundwaterLiquefied gas
Food and beverage productionGas‐containing liquids
Filtered waterHarmful liquids
Toxic liquidsHigh‐temperature hot water
Heating waterHighly aggressive liquids
Industrial service waterCondensate
Corrosive liquidsValuable liquids
FuelsCoolant
Cooling lubricantCooling water
Volatile liquidsFire‐fighting water
SolventsSeawater
OilsOrganic liquids
Pharmaceutical fluidsPolymerising liquids
Rainwater / stormwaterCleaning agents
Raw sludgeLubricants
Waste waterSwimming pool water
BrineFeed water
Dipping paintsDrinking water
Thermal oilHot water
Wash water
Overview of Applications
Overview of Applications
17
Fluids handled
Am
acan
KA
mac
an P
Am
acan
S
Am
amix
Am
apro
pA
maj
etA
mal
ine
Sew
atec
Sew
ablo
cK
WP
/ KW
P‐B
loc
WB
CLS
A‐S
LCC
‐M /
LCC
‐RTB
CLC
VFG
DM
ega
MH
DLH
DM
DX
ZW HV
F
Etap
rim
e L
Etap
rim
e B
/ B
NM
Z
Waste water with faeces
Sub
mer
sib
le p
um
ps
in d
isch
arg
e tu
bes
Mix
ers
/ ag
itat
ors
/ ta
nk
clea
nin
g u
nit
s
Pum
ps
for
solid
s‐la
den
flu
ids
Slu
rry
pu
mp
s
Self
‐pri
min
g p
um
ps
Waste water without faecesAggressive liquids
Inorganic liquidsActivated sludge
Brackish waterService water
DistillateSlurries
Explosive liquidsDigested sludge
Solids (ore, sand, gravel, ash)Flammable liquids
River, lake and groundwaterLiquefied gas
Food and beverage productionGas‐containing liquids
Filtered waterHarmful liquids
Toxic liquidsHigh‐temperature hot water
Heating waterHighly aggressive liquids
Industrial service waterCondensate
Corrosive liquidsValuable liquids
FuelsCoolant
Cooling lubricantCooling water
Volatile liquidsFire‐fighting water
SolventsSeawater
OilsOrganic liquids
Pharmaceutical fluidsPolymerising liquids
Rainwater / stormwaterCleaning agents
Raw sludgeLubricants
Waste waterSwimming pool water
BrineFeed water
Dipping paintsDrinking water
Thermal oilHot water
Wash water
Overview of Applications
Overview of Applications
18
Fluids handled
S 10
0 D
/ U
PA 1
00 C
UPA
150
CU
PA 2
00, 2
00B
, 250
CU
PA 3
00, 3
50U
PZ, B
SX‐B
SF
BEV
Mo
vite
c V
/ V
S / V
C /
LHS
Mo
vite
c V
CI
Mu
ltit
ec
Om
ega
RD
LOR
DLP
Vit
ach
rom
Vit
acas
tV
itap
rim
eV
itas
tag
eV
ital
ob
e
CH
TA /
CH
TC /
CH
TDH
GB
/ H
GC
/ H
GD
HG
MY
NK
LUV
/ LU
VA
WK
TBSE
Z / S
EZT
/ PH
Z / P
NZ
SNW
/ PN
WB
ever
on
SPY
Waste water with faecesSu
bm
ersi
ble
bo
reh
ole
pu
mp
s
Dee
p‐w
ell t
urb
ine
pu
mp
s
Hig
h‐p
ress
ure
pu
mp
s, f
ixed
/ va
riab
le s
pee
d
Axi
ally
sp
lit p
um
ps
Hyg
ien
ic p
um
ps
for
the
foo
d, b
ever
age
and
ph
arm
aceu
tica
l in
du
stri
es
Pum
ps
for
po
wer
sta
tio
n c
on
ven
tio
nal
isla
nd
s
Waste water without faecesAggressive liquids
Inorganic liquidsActivated sludge
Brackish waterService water
DistillateSlurries
Explosive liquidsDigested sludge
Solids (ore, sand, gravel, ash)Flammable liquids
River, lake and groundwaterLiquefied gas
Food and beverage productionGas‐containing liquids
Filtered waterHarmful liquids
Toxic liquidsHigh‐temperature hot water
Heating waterHighly aggressive liquids
Industrial service waterCondensate
Corrosive liquidsValuable liquids
FuelsCoolant
Cooling lubricantCooling water
Volatile liquidsFire‐fighting water
SolventsSeawater
OilsOrganic liquids
Pharmaceutical fluidsPolymerising liquids
Rainwater / stormwaterCleaning agents
Raw sludgeLubricants
Waste waterSwimming pool water
BrineFeed water
Dipping paintsDrinking water
Thermal oilHot water
Wash water
Overview of Applications
Overview of Applications
19
Fluids handled
RER
RSR
RU
VPS
RR
HD
LUV
Nu
clea
rR
HM
RV
MR
HR
RV
R
RPH
‐RO
HG
M‐R
OM
ult
itec
‐RO
SALI
NO
Pre
ssu
re C
ente
r
RC
/ R
CV
EDS
DU
/ EU
KSB
Su
Prem
E
Pum
pM
eter
Waste water with faeces
Pum
ps
for
nu
clea
r p
ow
er s
tati
on
s
Pum
ps
for
seaw
ater
des
alin
atio
n b
y re
vers
e o
smo
sis
Posi
tive
dis
pla
cem
ent
pu
mp
s
Fire
‐fig
hti
ng
sys
tem
s
Dri
ves
Mo
nit
ori
ng
an
d d
iag
no
sis
Waste water without faecesAggressive liquids
Inorganic liquidsActivated sludge
Brackish waterService water
DistillateSlurries
Explosive liquidsDigested sludge
Solids (ore, sand, gravel, ash)Flammable liquids
River, lake and groundwaterLiquefied gas
Food and beverage productionGas‐containing liquids
Filtered waterHarmful liquids
Toxic liquidsHigh‐temperature hot water
Heating waterHighly aggressive liquids
Industrial service waterCondensate
Corrosive liquidsValuable liquids
FuelsCoolant
Cooling lubricantCooling water
Volatile liquidsFire‐fighting water
SolventsSeawater
OilsOrganic liquids
Pharmaceutical fluidsPolymerising liquids
Rainwater / stormwaterCleaning agents
Raw sludgeLubricants
Waste waterSwimming pool water
BrineFeed water
Dipping paintsDrinking water
Thermal oilHot water
Wash water
Overview of Applications
Overview of Applications
20
Applications
Rio
ther
m
Rio
‐Th
erm
N
Rio
‐Eco
Th
erm
N
Cal
io T
her
m S
Cal
io S
Cal
io
Rio
‐Eco
N
Rio
‐Eco
Z N
Etal
ine
Etal
ine
Z
Etal
ine‐
R
ILN
/ IL
NE
/ ILN
S
ILN
C /
ILN
CE
/ ILN
CS
Etan
orm
/ Et
ano
rm‐R
Etab
loc
Etac
hro
m B
C
Etac
hro
m N
C
Etan
orm
V
HPK
‐L
HPH
HPK
Etan
orm
SY
T / R
SY
Etab
loc
SYT
/ Eta
line
SYT
Aquaculture
Cir
cula
tors
/ h
ot
wat
er s
ervi
ce p
um
ps,
fix
ed s
pee
d
Dri
nki
ng
wat
er c
ircu
lato
rs, f
ixed
sp
eed
Dri
nki
ng
wat
er c
ircu
lato
rs, v
aria
ble
sp
eed
Cir
cula
tors
, var
iab
le s
pee
d
In‐l
ine
pu
mp
s w
ith
fix
ed /
vari
able
sp
eed
dri
ve
Stan
dar
dis
ed /
clo
se‐c
ou
ple
d p
um
ps,
fix
ed /
vari
able
sp
eed
Ho
t w
ater
pu
mp
s
Ho
t w
ater
/ th
erm
al o
il p
um
ps
Spray irrigationMining
IrrigationChemical industry
Dock facilitiesDrainage
Pressure boostingSludge thickening
DisposalDewatering
Descaling unitsDistrict heatingSolids transport
Fire‐fighting systemsDrawdown of groundwater levels
Maintaining groundwater levelsDomestic water supply
Flood control / coast protection (stormwater)Homogenisation
Industrial recirculation systemsNuclear power stations
Boiler feed applicationsBoiler recirculation
Waste water treatment plantsAir‐conditioning systems
Condensate transportCooling circuits
Paint shopsFood and beverage industry
Seawater desalination / reverse osmosisMixing
Off‐shore platformsPaper and pulp industryPetrochemical industry
Pharmaceutical industryPipelines and tank farms
RefineryFlue gas desulphurisation
Rainwater harvestingCleaning of stormwater tanks / storage sewers
RecirculationDredging
ShipbuildingSludge disposal
Sludge processingSnow‐making systems
Heavy oil and coal upgradingSwimming pools
Solar thermal energy systemsFountains
Keeping in suspensionThermal oil circulation
Draining of pits, shafts, etc.Process engineering
Heat recovery systemsHot‐water heating systems
Washing plantsWater treatmentWater extraction
Water supplySugar industry
Overview of Applications
Overview of Applications
21
Applications
HX
(N
ikki
so‐K
SB)
HY
(N
ikki
so‐K
SB)
Meg
aCPK
CPK
N
Mag
no
chem
Mag
no
chem
‐Blo
c
Etas
eco
/ Et
asec
o‐I
Etas
eco
RV
P
Seco
chem
Ex
Seco
chem
Ex
K
Eco
chem
No
n‐S
eal H
N
Eco
chem
No
n‐S
eal H
T
Eco
chem
No
n‐S
eal H
P
Eco
chem
No
n‐S
eal H
S
HN
/ B
N /
TN (
Nik
kiso
‐KSB
)
HT
/ BT
/ TT
(Nik
kiso
‐KSB
)
HK
(N
ikki
so‐K
SB)
VN
(N
ikki
so‐K
SB)
DN
(N
ikki
so‐K
SB)
RPH
RPH
b
RPH
‐V
RPH
md
p
CTN
API
ser
ies
(Nik
kiso
‐KSB
)
CH
TR
YN
KR
CIN
CP
/ CIN
CN
INV
CP
/ IN
VC
N
RW
CP
/ RW
CN
WK
TR
Aquaculture
Ther
mal
oil
pu
mp
s w
ith
mag
net
ic d
rive
or
can
ned
mo
tor
Stan
dar
dis
ed c
hem
ical
pu
mp
s
Seal
‐les
s p
um
ps
Pro
cess
pu
mp
s
Spray irrigationMining
IrrigationChemical industry
Dock facilitiesDrainage
Pressure boostingSludge thickening
DisposalDewatering
Descaling unitsDistrict heatingSolids transport
Fire‐fighting systemsDrawdown of groundwater levels
Maintaining groundwater levelsDomestic water supply
Flood control / coast protection (stormwater)Homogenisation
Industrial recirculation systemsNuclear power stations
Boiler feed applicationsBoiler recirculation
Waste water treatment plantsAir‐conditioning systems
Condensate transportCooling circuits
Paint shopsFood and beverage industry
Seawater desalination / reverse osmosisMixing
Off‐shore platformsPaper and pulp industry
Petrochemical industryPharmaceutical industry
Pipelines and tank farmsRefinery
Flue gas desulphurisationRainwater harvesting
Cleaning of stormwater tanks / storage sewersRecirculation
DredgingShipbuilding
Sludge disposalSludge processing
Snow‐making systemsHeavy oil and coal upgrading
Swimming poolsSolar thermal energy systems
FountainsKeeping in suspensionThermal oil circulation
Draining of pits, shafts, etc.Process engineering
Heat recovery systemsHot‐water heating systems
Washing plantsWater treatmentWater extraction
Water supplySugar industry
Overview of Applications
Overview of Applications
22
Applications
Hya
‐Rai
n /
Hya
‐Rai
n N
Hya
‐Rai
n E
co
Mu
ltiE
co
Set
100
Mu
ltiE
co‐P
ro
Mu
ltiE
co‐T
op
Mo
vite
c V
ME
Ixo
N
Ixo
‐Pro
Filt
ra N
Hya
‐So
lo E
V
Hya
‐So
lo D
Hya
‐So
lo D
SV
Hya
‐So
lo D
FL
Hya
‐Du
o D
FL
Hya
‐So
lo D
FL
Co
mp
act
Hya
‐Du
o D
FL
Co
mp
act
Hya
‐Co
mp
act
K
Hya
‐Co
mp
act
VP
Sup
erb
loc
SBC
Surp
ress
Eco
SE.
2.B
Hya
‐Eco
VP
Hya
mat
K
Hya
mat
V
Hya
mat
SV
P
Aquaculture
Rai
nw
ater
har
vest
ing
sys
tem
s
Do
mes
tic
wat
er s
up
ply
sys
tem
s w
ith
au
tom
atic
co
ntr
ol u
nit
/ sw
imm
ing
po
ol p
um
ps
Pres
sure
bo
ost
er s
yste
ms
Spray irrigationMining
IrrigationChemical industry
Dock facilitiesDrainage
Pressure boostingSludge thickening
DisposalDewatering
Descaling unitsDistrict heatingSolids transport
Fire‐fighting systemsDrawdown of groundwater levels
Maintaining groundwater levelsDomestic water supply
Flood control / coast protection (stormwater)Homogenisation
Industrial recirculation systemsNuclear power stations
Boiler feed applicationsBoiler recirculation
Waste water treatment plantsAir‐conditioning systems
Condensate transportCooling circuits
Paint shopsFood and beverage industry
Seawater desalination / reverse osmosisMixing
Off‐shore platformsPaper and pulp industryPetrochemical industry
Pharmaceutical industryPipelines and tank farms
RefineryFlue gas desulphurisation
Rainwater harvestingCleaning of stormwater tanks / storage sewers
RecirculationDredging
ShipbuildingSludge disposal
Sludge processingSnow‐making systems
Heavy oil and coal upgradingSwimming pools
Solar thermal energy systemsFountains
Keeping in suspensionThermal oil circulation
Draining of pits, shafts, etc.Process engineering
Heat recovery systemsHot‐water heating systems
Washing plantsWater treatmentWater extraction
Water supplySugar industry
Overview of Applications
Overview of Applications
23
Applications
Surp
ress
Eco
SE.
2.B
VP
Surp
ress
chro
m S
IC.2
Surp
ress
chro
m S
IC.2
V
Surp
ress
chro
m S
IC.2
SV
P
Surp
ress
blo
c SB
Surp
ress
Feu
SFE
Surp
ress
SP
Surp
ress
SP
VP
Am
a‐D
rain
er N
301
– 3
58
Am
a‐D
rain
er 4
.. / 5
..
Am
a‐D
rain
er 8
0, 1
00
Am
a‐Po
rter
F /
S
Ro
tex
MK
/ M
KY
Am
aDS3
Am
a‐D
rain
er‐B
ox
Am
a‐D
rain
er‐B
ox
Min
i
Eva‐
Cle
an
min
i‐C
om
pac
ta
Co
mp
acta
Ko
nd
ensa
t‐Li
ft
CK
800
Pu
mp
Sta
tio
n
Am
a‐Po
rter
CK
Pu
mp
Sta
tio
n
Am
arex
N C
K P
um
p S
tati
on
Evam
atic
‐Bo
x
SRP
Am
arex
N
Am
arex
N S
32
Am
arex
KR
T
Am
arex
KR
T d
ry‐i
nst
alle
d
Am
arex
KR
T w
et‐/
dry
‐in
stal
led
Aquaculture
Pres
sure
bo
ost
er s
yste
ms
Dra
inag
e p
um
ps
/ was
te w
ater
pu
mp
s
Lift
ing
un
its
/ pu
mp
sta
tio
ns
Sub
mer
sib
le m
oto
r p
um
ps
Spray irrigationMining
IrrigationChemical industry
Dock facilitiesDrainage
Pressure boostingSludge thickening
DisposalDewatering
Descaling unitsDistrict heatingSolids transport
Fire‐fighting systemsDrawdown of groundwater levels
Maintaining groundwater levelsDomestic water supply
Flood control / coast protection (stormwater)Homogenisation
Industrial recirculation systemsNuclear power stations
Boiler feed applicationsBoiler recirculation
Waste water treatment plantsAir‐conditioning systems
Condensate transportCooling circuits
Paint shopsFood and beverage industry
Seawater desalination / reverse osmosisMixing
Off‐shore platformsPaper and pulp industry
Petrochemical industryPharmaceutical industry
Pipelines and tank farmsRefinery
Flue gas desulphurisationRainwater harvesting
Cleaning of stormwater tanks / storage sewersRecirculation
DredgingShipbuilding
Sludge disposalSludge processing
Snow‐making systemsHeavy oil and coal upgrading
Swimming poolsSolar thermal energy systems
FountainsKeeping in suspensionThermal oil circulation
Draining of pits, shafts, etc.Process engineering
Heat recovery systemsHot‐water heating systems
Washing plantsWater treatmentWater extraction
Water supplySugar industry
Overview of Applications
Overview of Applications
24
Applications
Am
acan
K
Am
acan
P
Am
acan
S
Am
amix
Am
apro
p
Am
ajet
Am
alin
e
Sew
atec
/ Se
wab
loc
KW
P / K
WP‐
Blo
c
WB
C
LSA
‐S
LCC
‐M /
LCC
‐R
TBC
LCV
FGD
Meg
a
MH
D
LHD
MD
X
ZW HV
F
Etap
rim
e L
Etap
rim
e B
/ B
N
MZ
Aquaculture
Sub
mer
sib
le p
um
ps
in d
isch
arg
e tu
bes
Mix
ers
/ ag
itat
ors
/ ta
nk
clea
nin
g u
nit
s
Pum
ps
for
solid
s‐la
den
flu
ids
Slu
rry
pu
mp
s
Self
‐pri
min
g p
um
ps
Spray irrigationMining
IrrigationChemical industry
Dock facilitiesDrainage
Pressure boostingSludge thickening
DisposalDewatering
Descaling unitsDistrict heatingSolids transport
Fire‐fighting systemsDrawdown of groundwater levels
Maintaining groundwater levelsDomestic water supply
Flood control / coast protection (stormwater)Homogenisation
Industrial recirculation systemsNuclear power stations
Boiler feed applicationsBoiler recirculation
Waste water treatment plantsAir‐conditioning systems
Condensate transportCooling circuits
Paint shopsFood and beverage industry
Seawater desalination / reverse osmosisMixing
Off‐shore platformsPaper and pulp industryPetrochemical industry
Pharmaceutical industryPipelines and tank farms
RefineryFlue gas desulphurisation
Rainwater harvestingCleaning of stormwater tanks / storage sewers
RecirculationDredging
ShipbuildingSludge disposal
Sludge processingSnow‐making system
Heavy oil and coal upgradingSwimming pools
Solar thermal energy systemsFountains
Keeping in suspensionThermal oil circulation
Draining of pits, shafts, etc.Process engineering
Heat recovery systemsHot‐water heating systems
Washing plantsWater treatmentWater extraction
Water supplySugar industry
Overview of Applications
Overview of Applications
25
Applications
S 10
0 D
/ U
PA 1
00 C
UPA
150
C
UPA
200
, 200
B, 2
50C
UPA
300
, 350
UPZ
, BSX
‐BSF
BEV
Mo
vite
c V
/ V
S / V
C /
LHS
Mo
vite
c V
CI
Mu
ltit
ec
Om
ega
RD
LO
RD
LP
Vit
ach
rom
Vit
acas
t
Vit
apri
me
Vit
asta
ge
Vit
alo
be
CH
TA /
CH
TC /
CH
TD
HG
B /
HG
C /
HG
D
HG
M
YN
K
LUV
/ LU
VA
WK
TB
SEZ
/ SEZ
T / P
HZ
/ PN
Z
SNW
/ PN
W
Bev
ero
n
SPY
Aquaculture
Sub
mer
sib
le b
ore
ho
le p
um
ps
Dee
p‐w
ell t
urb
ine
pu
mp
s
Hig
h‐p
ress
ure
pu
mp
s, f
ixed
/ va
riab
le s
pee
d
Axi
ally
sp
lit p
um
ps
Hyg
ien
ic p
um
ps
for
the
foo
d, b
ever
age
and
ph
arm
aceu
tica
l in
du
stri
es
Pum
ps
for
po
wer
sta
tio
n c
on
ven
tio
nal
isla
nd
s
Spray irrigationMining
IrrigationChemical industry
Dock facilitiesDrainage
Pressure boostingSludge thickening
DisposalDewatering
Descaling unitsDistrict heatingSolids transport
Fire‐fighting systemsDrawdown of groundwater levels
Maintaining groundwater levelsDomestic water supply
Flood control / coast protection (stormwater)Homogenisation
Industrial recirculation systemsNuclear power stations
Boiler feed applicationsBoiler recirculation
Waste water treatment plantsAir‐conditioning systems
Condensate transportCooling circuits
Paint shopsFood and beverage industry
Seawater desalination / reverse osmosisMixing
Off‐shore platformsPaper and pulp industry
Petrochemical industryPharmaceutical industry
Pipelines and tank farmsRefinery
Flue gas desulphurisationRainwater harvesting
Cleaning of stormwater tanks / storage sewersRecirculation
DredgingShipbuilding
Sludge disposalSludge processing
Snow‐making systemHeavy oil and coal upgrading
Swimming poolsSolar thermal energy systems
FountainsKeeping in suspensionThermal oil circulation
Draining of pits, shafts, etc.Process engineering
Heat recovery systemsHot‐water heating systems
Washing plantsWater treatmentWater extraction
Water supplySugar industry
Overview of Applications
Overview of Applications
26
Applications
RER
RSR
RU
V
PSR
RH
D
LUV
Nu
clea
r
RH
M
RV
M
RH
R
RV
R
RPH
‐RO
HG
M‐R
O
SALI
NO
Pre
ssu
re C
ente
r
RC
/ R
CV
EDS
DU
/ EU
KSB
Su
Prem
E
Pum
pM
eter
Aquaculture
Pum
ps
for
nu
clea
r p
ow
er s
tati
on
s
Pum
ps
for
seaw
ater
des
alin
atio
n b
y re
vers
e o
smo
sis
Posi
tive
dis
pla
cem
ent
pu
mp
s
Fire
‐fig
hti
ng
sys
tem
s
Dri
ves
Mo
nit
ori
ng
an
d d
iag
no
sis
Spray irrigationMining
IrrigationChemical industry
Dock facilitiesDrainage
Pressure boostingSludge thickening
DisposalDewatering
Descaling unitsDistrict heatingSolids transport
Fire‐fighting systemsDrawdown of groundwater levels
Maintaining groundwater levelsDomestic water supply
Flood control / coast protection (stormwater)Homogenisation
Industrial recirculation systemsNuclear power stations
Boiler feed applicationsBoiler recirculation
Waste water treatment plantsAir‐conditioning systems
Condensate transportCooling circuits
Paint shopsFood and beverage industry
Seawater desalination / reverse osmosisMixing
Off‐shore platformsPaper and pulp industryPetrochemical industry
Pharmaceutical industryPipelines and tank farms
RefineryFlue gas desulphurisation
Rainwater harvestingCleaning of stormwater tanks / storage sewers
RecirculationDredging
ShipbuildingSludge disposal
Sludge processingSnow‐making system
Heavy oil and coal upgradingSwimming pools
Solar thermal energy systemsFountains
Keeping in suspensionThermal oil circulation
Draining of pits, shafts, etc.Process engineering
Heat recovery systemsHot‐water heating systems
Washing plantsWater treatmentWater extraction
Water supplySugar industry
Automation
Automation
27
Drive, variable speed system and monitoring
KSB SuPremENo. of pumpsVoltage [V]
max. 1Power supply viaPumpDrive only
Description:IEC‐compatible, sensorless, magnetless synchronous reluctance motor ofefficiency class IE4 (super premium efficiency) to IEC/CD 60034‐30 Ed. 2.0(05‐2011) for operation with the KSB PumpDrive S or KSB PumpDrive Rvariable speed system. Suitable for connection to three‐phase 380‐480 Vmains (via PumpDrive). The motor mounting points comply with EN 50347specifications to ensure compatibility with standardised IEC frame motorapplications and full interchangeability with IE2 or IE3 standardisedasynchronous motors. Envelope dimensions lie within the limits for IE2 /IE3 motors as recommended in DIN V 42673 (07‐2011). The motor iscontrolled without rotor position indicators. The efficiency of the motoralso exceeds 95 percent of nominal efficiency when the motor runs at 25percent of its nominal power on a quadratic torque‐speed curve. Themotor is magnetless which means that, in particular, so‐called rare earthsare not used in production. Drive production is thus sustainable andenvironmentally friendly.Applications:For use with dry‐installed variable speed pumps which can be driven bystandardised foot‐mounted and/or flange‐mounted motors.
http://shop.ksb.com/catalog/k0/en/product/ES000866
PumpDrive 2 / PumpDrive 2 EcoNo. of pumpsP [kW]Voltage [V]Frequencyinverter
max. 655
3~380 – 4801 per motor
Description:Self‐cooling variable speed system which allows the motor speed to bevaried continuously by means of standard signals and a field bus. AsPumpDrive is self‐cooling, it can be mounted on the motor, on the wall orin a control cabinet. From two to six pumps can be controlled withoutneeding an additional controller.Applications:Cooling circuits, filters, water supply systems, heating, ventilation and air‐conditioning systems, spray irrigation systems, boiler feed systems, steamgeneration plants, process circuits, cooling lubricant supply systems,service water supply systems and other process engineering applications.
http://shop.ksb.com/catalog/k0/en/product/ES000536
PumpMeterNo. of pumpsVoltage [V]
max. 124 V DC
Description:The PumpMeter device is an intelligent pressure transmitter for pumps,with on‐site display of measured values and operating data. The devicecomprises two pressure sensors and a display unit. It records the loadprofile of the pump in order to indicate any potential for optimisingenergy efficiency and availability.Applications:For monitoring the operation of a centrifugal pump.
http://shop.ksb.com/catalog/k0/en/product/ES000807
Pumps
Pumps
28
Circulators / hot water service pumps, fixed speed
RiothermRpQ [m3/h]H [m]p [bar]T [°C]
1 – 1¼max. 10
max. 6max. 10
‐2 to +110
Description:Screw‐ended glanded pump with mechanical seal and fixed speed.Applications:Hot water supply, swimming pools, cooling circuits and industrial plants.
Data for 50 Hz operation
Also available for 60 Hz
Switchgear http://shop.ksb.com/catalog/k0/en/product/ES000131
Drinking water circulators, fixed speed
Rio‐Therm NRp / DNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
½ – 1¼ / 40 – 80max. 50
max. 9max. 10
max. +80max. 2800
Description:Maintenance‐free screw‐ended or flanged glandless pump, with up tofour speed levels.Applications:Hot water supply, drinking water circulation systems and similar systemsin industry and building services (e.g. cooling water recirculation).
Data for 50 Hz operation
Available for 50 Hz and 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000132
Drinking water circulators, variable speed
Rio‐Eco Therm NRp / DNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1 – 1¼ / 32 – 80max. 38max. 12max. 10
max. +80max. 3700
Description:Maintenance‐free high‐efficiency flanged or screw‐ended glandless pumpwith high‐efficiency electric motor and continuously variable differentialpressure control.Applications:Hot water supply, drinking water circulation systems and similar systemsin industry and building services (e.g. cooling water recirculation).
Data for 50 Hz operation
Suitable for 50 Hz and 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000877
Calio Therm SRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1 – 1¼max. 3.5
max. 6max. 10
max. +80max. 3000
Description:Maintenance‐free high‐efficiency screw‐ended glandless pump with high‐efficiency electric motor and continuously variable differential pressurecontrol.Applications:Hot water supply, drinking water circulation systems and similar systemsin industry and building services (e.g. cooling water recirculation).
Data for 50 Hz operation
Suitable for 50 Hz and 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000882
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
29
Circulators, variable speed
Calio SRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]
½ – 1¼max. 3.5
max. 6max. 10
+5 to +95max. 3000
Description:Maintenance‐free high‐efficiency screw‐ended glandless pump with high‐efficiency electric motor and continuously variable differential pressurecontrol.Applications:Heating, ventilation, air‐conditioning and heat recovery systems, coolingsystems, industrial recirculation systems.
Suitable for 50 Hz and 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000881
CalioRp / DNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1 – 1¼ / 32 – 100max. 70max. 18max. 16
‐10 to +110max. 3660
Description:Maintenance‐free high‐efficiency flanged or screw‐ended glandless pumpwith high‐efficiency electric motor and continuously variable differentialpressure control.Applications:Heating, ventilation, air‐conditioning and heat recovery systems, coolingsystems, industrial recirculation systems.
Suitable for 50 Hz and 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000881
Rio‐Eco NRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 32 – 80max. 65max. 14max. 10
‐10 to +110
Description:Maintenance‐free high‐efficiency flanged or screw‐ended glandless pumpwith high‐efficiency electric motor and continuously variable differentialpressure control.Applications:Heating, ventilation, air‐conditioning and heat recovery systems, coolingsystems, industrial recirculation systems.Suitable for 50 Hz and 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000493
Rio‐Eco Z NDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
32 – 80max. 46max. 14max. 10
‐10 to +110max. 3550
Description:Maintenance‐free glandless pump with integrated frequency inverter forcontinuously variable differential pressure control.Applications:Heating, ventilation, air‐conditioning and heat recovery systems, coolingsystems, industrial recirculation systems.
Suitable for 50 Hz and 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000493
Pumps
Pumps
30
In‐line pumps with fixed / variable speed drive
EtalineDNQ [m3/h]H [m]p [bar]T [°C]
32 – 200max. 700
max. 95max. 16
‐30 to +140
Description:Single‐stage volute casing pump in in‐line design with standardisedmotor; pump shaft and motor shaft are rigidly connected.Applications:Hot‐water heating systems, cooling circuits, air‐conditioning systems,water supply systems, service water supply systems and industrialrecirculation systems.Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter, Switchgear http://shop.ksb.com/catalog/k0/en/product/ES000113
Etaline ZDNQ [m3/h]H [m]p [bar]T [°C]
32 – 200max. 1095max. 38.5
max. 16‐30 to +140
Description:Single‐stage volute casing pump in in‐line twin design with standardisedmotor; pump shaft and motor shaft are rigidly connected.Applications:Hot‐water heating systems, cooling circuits, air‐conditioning systems,water supply systems, service water supply systems and industrialrecirculation systems.Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter, Switchgear http://shop.ksb.com/catalog/k0/en/product/ES000114
Etaline‐RDNQ [m3/h]H [m]p [bar]T [°C]
150 – 350max. 1900
max. 93max. 25
‐30 to +140
Description:Vertical, close‐coupled pump with volute casing in in‐line design andstandardised motor.Applications:Hot‐water heating systems, cooling circuits, air‐conditioning systems,water supply systems, service water supply systems and industrialrecirculation systems.Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter, Switchgear http://shop.ksb.com/catalog/k0/en/product/ES000812
ILN / ILNE / ILNSDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
65 – 400max. 3100
max. 112max. 16
‐20 to +70max. 3000
Description:Vertical in‐line centrifugal pump with closed impeller and mechanicalseal. ILNS fitted with an auxiliary vacuum pump, ILNE with ejector. Backpull‐out design allows the impeller to be dismantled without removingthe pipes and the motor.Applications:Hot‐water heating systems, cooling circuits, air‐conditioning systems,marine applications, water and service water supply systems, cleaningsystems and industrial recirculation systems.
Data for 50 Hz operation
Also suitable for 60 Hz operation
PumpDrive, Switchgear http://shop.ksb.com/catalog/k0/en/product/ES000730
ILNC / ILNCE / ILNCSDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
32 – 125max. 370max. 112
max. 16‐20 to +70max. 3000
Description:Vertical close‐coupled centrifugal pump in in‐line design, with electricmotor, closed impeller and mechanical seal. ILNCS fitted with an auxiliaryvacuum pump, ILNCE with ejector. Standardised IEC frame motor.Applications:Hot‐water heating systems, cooling circuits, air‐conditioning systems,marine applications, water and service water supply systems, cleaningsystems and industrial recirculation systems.Data for 50 Hz operation
Also suitable for 60 Hz operation
PumpDrive, Switchgear http://shop.ksb.com/catalog/k0/en/product/ES000732
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
31
Standardised / close‐coupled pumps, fixed / variable speed
EtanormDNQ [m3/h]H [m]p [bar]T [°C]
25 – 200max. 660max. 160
max. 16max. +140
Description:Volute casing pump, single‐stage, ratings to EN 733, meets therequirements of the 2009/125/EC directive, radially split volute casing,volute casing with integrally cast pump feet, replaceable casing wearrings (optionally available for casings in material variant C), closed radialimpeller with multiply curved vanes, single mechanical seals to EN 12756,double mechanical seals to EN 12756, shaft fitted with a replaceable shaftprotecting sleeve in the shaft seal area.Applications:For pumping pure liquids not chemically or mechanically aggressive to thepump materials: water supply, cooling water, swimming pool water, fire‐fighting systems, seawater, spray irrigation, fire‐fighting water, irrigation,service water, cleaning agents, drinking water, brackish water, drainage,condensate, heating, air‐conditioning, oils, hot water.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000062
Etanorm‐RDNQ [m3/h]H [m]p [bar]T [°C]
32 – 300max. 1900
max. 102max. 16
max. +140
Description:Horizontal volute casing pump, single‐stage (size 125‐500 with twostages), long‐coupled, in back pull‐out design, with replaceable shaftsleeves / shaft protecting sleeves and casing wear rings. ATEX‐compliantversion available.Applications:Spray irrigation, irrigation, drainage, district heating, water supplysystems, heating and air‐conditioning systems, condensate transport,swimming pools, fire‐fighting systems, handling hot water, cooling water,fire‐fighting water, oil, brine, drinking water, brackish water, servicewater, etc.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000058
EtablocDNQ [m3/h]H [m]p [bar]T [°C]
25 – 150max. 612max. 102
max. 16max. +140
Description:Volute casing pump, single‐stage, ratings to EN 733, meets therequirements of the 2009/125/EC directive, radially split volute casing(some volute casings with integrally cast pump feet), replaceable casingwear rings (optionally available for casings in material variant C), closedradial impeller with multiply curved vanes, single mechanical seals toEN 12756, double mechanical seals to EN 12756, shaft fitted with areplaceable shaft protecting sleeve in the shaft seal area.Applications:Spray irrigation, irrigation, drainage, water supply systems, heating andair‐conditioning systems, condensate transport, swimming pools, handlinghot water, cooling water, fire‐fighting water, seawater, oil, brine,drinking water, cleaning agents, brackish water, service water, etc.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000107
Etachrom BCDNQ [m3/h]H [m]p [bar]T [°C]
25 – 80max. 260max. 106
max. 12max. +110
Description:Horizontal single‐stage close‐coupled annular casing pump, with ratingsand main dimensions to EN 733, with replaceable casing wear rings.ATEX‐compliant version available.Applications:Spray irrigation, irrigation, drainage, water supply systems, heating, air‐conditioning and fire‐fighting systems, condensate transport, swimmingpools, handling hot water, cooling water, fire‐fighting water, oil, drinkingwater, cleaning agents and service water.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000066
Pumps
Pumps
32
Etachrom NCDNQ [m3/h]H [m]p [bar]T [°C]
25 – 80max. 260max. 106
max. 12max. +110
Description:Horizontal single‐stage annular casing pump with ratings and maindimensions to EN 733, with replaceable casing wear rings. ATEX‐compliant version available.Applications:Water supply systems, spray irrigation, irrigation, drainage, heating, air‐conditioning and fire‐fighting systems, handling drinking water, servicewater, hot water, cooling water, swimming pool water, fire‐fightingwater, condensate, oil and cleaning agents.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000065
Etanorm VDNQ [m3/h]H [m]p [bar]T [°C]
32 – 150max. 660max. 102
max. 16max. +95
Description:Single‐stage volute casing pump for vertical installation in closed tanksunder atmospheric pressure, with ratings to EN 733. Suitable forimmersion depths of up to 2000 mm.Applications:For pumping neutral degreasing and phosphatising solutions, wash waterwith degreasing agents, dipping paints, etc.Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000015
Hot water pumps
HPK‐LDNQ [m3/h]H [m]p [bar]T [°C]
25 – 250max. 1160
max. 162max. 40
max. +240 / +400
Description:Horizontal radially split volute casing pump in back pull‐out design toISO 2858 / ISO 5199, single‐stage, single‐entry, with radial impeller.Equipped with heat barrier, seal chamber air‐cooled by integrated fanimpeller, no external cooling. ATEX‐compliant version available.Applications:For pumping hot water and thermal oil in piping or tank systems,particularly in medium‐sized and large hot‐water heating systems, forcedcirculation boilers, district heating systems, etc.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000036
HPKDNQ [m3/h]H [m]p [bar]T [°C]
150 – 400max. 4150
max. 185max. 40
max. +400
Description:Horizontal radially split volute casing pump in back pull‐out design, withradial impeller, single‐entry, single‐stage, to ISO 2858 / ISO 5199. OptionalTRD type testing by TÜV. ATEX‐compliant version available.Applications:For pumping hot water and thermal oil in piping or tank systems,particularly in medium‐sized and large hot‐water heating systems, forcedcirculation boilers, district heating systems, etc.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000034
HPHDNQ [m3/h]H [m]p [bar]T [°C]
40 – 350max. 2350
max. 225max. 110
max. +320
Description:Horizontal radially split volute casing pump in back pull‐out design, withcentreline pump feet, with radial impeller, single‐entry, single‐stage.Optional TRD type testing by TÜV. ATEX‐compliant version available.Applications:For pumping hot water in high‐pressure hot water generation plants, asboiler feed or recirculation pump.Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000037
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
33
Hot water / thermal oil pumps
Etanorm SYT / RSYDNQ [m3/h]H [m]p [bar]T [°C]
32 – 300max. 1900
max. 102max. 16
max. +350
Description:Volute casing pump for horizontal installation, back pull‐out design,single‐stage, ratings and dimensions to EN 733, radially split volute casing,volute casing with integrally cast pump feet, replaceable casing wearrings, closed radial impeller with multiply curved vanes, single mechanicalseal to EN 12756, double mechanical seal to EN 12756, drive‐end bearings:rolling element bearings, pump‐end bearings: plain bearings.Applications:Heat transfer systems (DIN 4754, VDI 3033) or hot water recirculation.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000790
Etabloc SYTDNQ [m3/h]H [m]p [bar]T [°C]
25 – 80max. 280
max. 68max. 16
max. +350
Description:Volute casing pump for horizontal and vertical installation, back pull‐outdesign, single‐stage, with ratings to EN 733, radially split volute casing,replaceable casing wear rings, volute casing with integrally cast pumpfeet, closed radial impeller with multiply curved vanes, single mechanicalseal to EN 12756, product‐lubricated carbon plain bearing and grease‐lubricated radial ball bearing in the motor housing.Applications:Heat transfer systems (DIN 4754, VDI 3033) or hot water recirculation.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000791
Etaline SYTDNQ [m3/h]H [m]p [bar]T [°C]
32 – 100max. 316
max. 69max. 16
max. +350
Description:Single‐stage volute casing pump in in‐line design with standardisedmotor; pump shaft and motor shaft are rigidly connected.Applications:Heat transfer systems (DIN 4754, VDI 3033) or hot water recirculation.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000789
Pumps
Pumps
34
Thermal oil pumps with magnetic drive or canned motor
HX (Nikkiso‐KSB)DNQ [m3/h]H [m]p [bar]T [°C]
32 – 100max. 200max. 100
max. 40max. +350
Description:Horizontal seal‐less single‐stage pump with fully enclosed canned motor,uncooled. ATEX‐compliant version available.Applications:For pumping thermal oils and other hot fluids in heat transfer systems toDIN 4754.
Data for 50 Hz operation
Also available for 60 Hz
HY (Nikkiso‐KSB)DNQ [m3/h]H [m]p [bar]T [°C]
32 – 80max. 150max. 100
max. 40max. +250
Description:Horizontal seal‐less single‐stage pump with fully enclosed canned motor,uncooled, coolable or heatable. ATEX‐compliant version available.Applications:For pumping thermal oils and other hot fluids in heat transfer systems toDIN 4754.
Data for 50 Hz operation
Also available for 60 Hz
Standardised chemical pumps
MegaCPKDNQ [m3/h]H [m]p [bar]T [°C]
25 – 250max. 1160
max. 162max. 25
max. +400
Description:Horizontal radially split volute casing pump in back pull‐out design, withradial impeller, single‐entry, single‐stage, to DIN EN ISO 2858 / ISO 5199;also available as a variant with "wet" shaft and conical seal chamber.ATEX‐compliant version available.Applications:For pumping aggressive liquids in the chemical and petrochemicalindustries and in refinery systems.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000861
CPKNDNQ [m3/h]H [m]p [bar]T [°C]
150 – 4001160 – 4150
162 – 185max. 25
max. +400
Description:Horizontal radially split volute casing pump in back pull‐out design, withradial impeller, single‐entry, single‐stage, to ISO 2858 / ISO 5199. Alsoavailable as variant with "wet" shaft, conical seal chamber and/or semi‐open impeller (CPKNO). ATEX‐compliant version available.Applications:For pumping aggressive liquids in the chemical and petrochemicalindustries, refinery systems, fire‐fighting systems and for brine transport.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000027
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
35
Seal‐less pumps
MagnochemDNQ [m3/h]H [m]p [bar]T [°C]
25 – 250max. 1160
max. 162max. 40
‐90 to +300
Description:Horizontal, seal‐less volute casing pump in back pull‐out design, withmagnetic drive, to DIN EN ISO 2858 / ISO 5199, with radial impeller, single‐entry, single‐stage. ATEX‐compliant version available.Applications:For pumping aggressive, toxic, explosive, valuable, flammable,malodorous or harmful liquids in the chemical, petrochemical and generalindustries.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000046
Magnochem‐BlocDNQ [m3/h]H [m]p [bar]T [°C]
25 – 160max. 754max. 162
max. 25max. +200
Description:Horizontal, seal‐less volute casing pump in close‐coupled design, withmagnetic drive, to DIN EN ISO 2858 / ISO 5199, with radial impeller, single‐entry, single‐stage. ATEX‐compliant version available.Applications:For pumping aggressive, toxic, explosive, valuable, flammable,malodorous or harmful liquids in the chemical, petrochemical and generalindustries.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000045
Etaseco / Etaseco‐IDNQ [m3/h]H [m]p [bar]T [°C]
32 – 100max. 250max. 162
max. 16max. +140
Description:Horizontal or vertical seal‐less volute casing pump in back pull‐out designwith fully enclosed canned motor, low noise emission, with radialimpeller, single‐stage, single‐entry, casing connecting dimensions toEN 733.Applications:For pumping aggressive, flammable, toxic, volatile, or valuable liquids inthe chemical and petrochemical industries, in environmental engineeringand industrial applications.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000122
Etaseco RVPDNQ [m3/h]H [m]p [bar]T [°C]
32max. 20max. 25max. 10
max. + 85
Description:Horizontal or vertical seal‐less volute casing pump in back pull‐out designwith fully enclosed canned motor, low noise emission, with radialimpeller, single‐stage, single‐entry.Applications:For pumping toxic, volatile or valuable liquids in environmentalengineering and industrial applications and as coolant pump in coolingsystems. Transport vehicles, environmental engineering and industry;applications where low noise emission, smooth running or long serviceintervals are required.
Also available for 60 Hz
PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000122
Secochem ExDNQ [m3/h]H [m]p [bar]T [°C]
25 – 100max. 300max. 150
max. 25max. +130
Description:Horizontal seal‐less volute casing pump in back pull‐out design with fullyenclosed canned motor, low noise emission, with radial impeller, single‐stage, single‐entry, casing connecting dimensions to EN 22858 / ISO 2858.ATEX‐compliant version available.Applications:For pumping aggressive, flammable, explosive, toxic, volatile or valuableliquids in the chemical and petrochemical industries, in environmentalengineering and industrial applications.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, Frequency inverter http://shop.ksb.com/catalog/k0/en/product/ES000105
Pumps
Pumps
36
Secochem Ex KDNQ [m3/h]H [m]p [bar]T [°C]
25 – 100max. 300max. 150
max. 25max. +400
Description:Horizontal seal‐less volute casing pump in back pull‐out design with fullyenclosed canned motor, low noise emission, with radial impeller, single‐stage, single‐entry, casing connecting dimensions to EN 22858 / ISO 2858,with external cooler. ATEX‐compliant version available.Applications:For pumping aggressive, flammable, explosive, toxic, volatile or valuableliquids in the chemical and petrochemical industries, in environmentalengineering and industrial applications.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, Frequency inverter http://shop.ksb.com/catalog/k0/en/product/ES000105
Ecochem Non‐Seal HN, HP, HT, HSDNQ [m3/h]H [m]p [bar]T [°C]
25 – 250max. 690max. 236
max. 40max. +400
Description:Horizontal seal‐less volute casing pump in back pull‐out design withhermetically sealed canned motor, low‐noise design, with radial impeller,single‐stage, single‐entry, casing connecting dimensions to EN 22858 /ISO 2858, available in standard chemical pump design (HN), with externalcooler for hot (HT) or contaminated (HS) fluids, and with internal returnline for handling liquefied gas (HP). ATEX‐compliant and GOST‐TR‐compliant versions available.Applications:For pumping aggressive, flammable and explosive liquids in the chemicaland petrochemical industries and in refinery and heat transfer systems.
PumpDrive, Frequency inverter
HN (Nikkiso‐KSB)DNQ [m3/h]H [m]p [bar]T [°C]
32 – 300max. 800max. 200
max. 40max. +180
Description:Horizontal (HN) or vertical (BN / TN) seal‐less single‐stage pump with fullyenclosed canned motor, uncooled, coolable or heatable. ATEX‐compliantversion available.Applications:For pumping aggressive, flammable, explosive, toxic, volatile or valuableliquids in the chemical and petrochemical industries.Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, Frequency inverter
HT (Nikkiso‐KSB)DNQ [m3/h]H [m]p [bar]T [°C]
32 – 300max. 800max. 200
max. 40max. +400
Description:Horizontal (HT) or vertical (BT / TT) seal‐less single‐stage pump with fullyenclosed canned motor, coolable. ATEX‐compliant version available.Applications:For pumping aggressive, solids‐laden, polymerising, flammable, explosive,toxic, volatile or valuable liquids and thermal oils in the chemical andpetrochemical industries.Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, Frequency inverter
HK (Nikkiso‐KSB)DNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
25 – 40max. 10
max. 300max. 40
max. +150max. 8400
Description:Horizontal seal‐less pump with fully enclosed canned motor, two‐stagedesign in tandem arrangement. ATEX‐compliant version available.Applications:For pumping aggressive, flammable, explosive, toxic, volatile or valuableliquids in the chemical and petrochemical industries. For low flow rates,high heads and low NPSHR.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, Frequency inverter
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
37
VN (Nikkiso‐KSB)DNQ [m3/h]H [m]p [bar]T [°C]
40 – 100max. 140max. 450
max. 40max. +180
Description:Horizontal seal‐less pump with fully enclosed canned motor, multistage.ATEX‐compliant version available.Applications:For pumping aggressive, flammable, explosive, toxic, volatile or valuableliquids in the chemical and petrochemical industries. For high pumpheads.Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, Frequency inverter
DN (Nikkiso‐KSB)DNQ [m3/h]H [m]p [bar]T [°C]
32 – 50max. 40max. 60max. 40
max. +180
Description:Horizontal seal‐less pump with fully enclosed canned motor , single‐stage,self‐priming. ATEX‐compliant version available.Applications:For pumping aggressive, flammable, explosive, toxic, volatile or valuableliquids in the chemical and petrochemical industries. Self‐priming pumpfor draining tanks and unloading tank vehicles.Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, Frequency inverter
Process pumps
RPHDNQ [m3/h]H [m]p [bar]T [°C]
25 – 400max. 4150
max. 270max. 110
‐70 to +450
Description:Horizontal radially split volute casing pump in back pull‐out design, toAPI 610, ISO 13709 (heavy‐duty), type OH2, with radial impeller, single‐entry, single‐stage, centreline pump feet; with inducer, if required. ATEX‐compliant version available.Applications:Refineries, petrochemical and chemical industries, power stations.Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000040
RPHbDNQ [m3/h]H [m]p [bar]T [°C]
80 – 200max. 750max. 430max. 100
max. +450
Description:Horizontal radially split volute casing pump in back pull‐out design, toAPI 610, ISO 13709 (heavy‐duty), type BB2, with radial impeller, single‐entry, single‐stage, back‐to‐back impeller arrangement, centreline pumpfeet.Applications:Refineries, petrochemical and chemical industries.Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000041
RPH‐VDNQ [m3/h]H [m]p [bar]T [°C]
40 – 150max. 80
max. 240max. 35
‐30 to +230
Description:Vertical radially split volute casing pump to API 610 and ISO 13709 (heavy‐duty), type VS4, with radial impeller, single‐entry, single‐stage.Applications:Refineries, petrochemical and chemical industries.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000880
Pumps
Pumps
38
RPHmdpDNQ [m3/h]H [m]p [bar]T [°C]
25 – 100max. 300max. 270
max. 51‐40 to +300
Description:Horizontal radially split volute casing pump in back pull‐out design toAPI 685 (heavy‐duty), with magnetic drive, single‐stage, single‐entry, withradial impeller, centreline pump feet; with inducer, if required. ATEX‐compliant version available.Applications:Refineries, petrochemical and chemical industries, power stations.Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000884
CTNDNQ [m3/h]H [m]p [bar]T [°C]
25–250 / 250–400max. 950max. 115
max. 16max. +300
Description:Radially split vertical shaft submersible pump with double volute casingfor wet and dry installation, with radial impeller, single‐entry, single‐stageor double‐stage; heatable model available. ATEX‐compliant versionavailable.Applications:For pumping chemically aggressive liquids, also slightly contaminated orwith a low solids content, in the chemical and petrochemical industries.
Data for 50 Hz operation
Available for 50 Hz and 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000014
API series (Nikkiso‐KSB)DNQ [m3/h]H [m]p [bar]T [°C]
1½ – 6max. 360max. 220
max. 40max. +450
Description:Horizontal or vertical canned motor pump to API 685, single‐stage, withcentreline pump feet; with inducer, if required.Applications:HNP: for clean liquids; HTP: for hot fluids; HSP / HMP: for contaminated orpolymerising fluids; HRP: for liquids with a steep vapour pressure curvesuch as liquefied gases.Data for 50 Hz operation
Also available for 60 Hz
CHTRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
50 – 300max. 1450max. 4000
max. 400max. +450max. 7000
Description:Horizontal high‐pressure barrel‐type pumps with radial impellers, single‐entry and double‐entry, multistage, with flanges or weld end nozzles toDIN, API 610 and ANSI.Applications:Refineries, petrochemical industry, steam generation, seawater injectionin crude oil production (onshore and offshore).
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000241
YNKRDNQ [m3/h]H [m]p [bar]T [°C]
250 / 350max. 3800
max. 390max. 60
max. +400
Description:Horizontal radially split single‐stage pump with double or single volutecasing, with double‐entry impeller, made of cast steel, to API 610,type BB2.Applications:Refineries, petrochemical industry, solar thermal systems and steamgeneration.Data for 50 Hz operation
Also available for 60 Hz
Other ratings possible on request
http://shop.ksb.com/catalog/k0/en/product/ES000849
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
39
CINCP / CINCNDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
32 – 200max. 780max. 105
max. 10‐10 to +100max. 3000
Description:Vertical immersion pump in cantilever design for wet or dry installation.Semi‐open impeller, pump shaft without guide bearings, supported byball bearings in the upper section. Supplied with discharge pipe extendingabove the baseplate (CINCP) or without discharge pipe (CINCN). ATEX‐compliant version available.Applications:Chemical and petrochemical industries, raw materials extraction andwaste water management.
Data for 50 Hz operation
Also suitable for 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000718
INVCP / INVCNDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
32 – 300max. 1600
max. 116max. 10
‐10 to +100max. 3000
Description:Vertical immersion pump for wet or dry installation, available with closedor semi‐open impeller. Supplied with discharge pipe extending above thebaseplate (INVCP) or without discharge pipe (INVCN). ATEX‐compliantversion available.Applications:For pumping chemically aggressive, slightly contaminated or solids‐ladenfluids in the chemical and petrochemical industries.Data for 50 Hz operation
Also suitable for 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000737
RWCP / RWCNDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
50 – 200max. 700max. 100
max. 16‐10 to +100max. 3000
Description:Process pump with free‐flow impeller, semi‐open or two‐channel or three‐channel impeller. Shaft sealed by mechanical seal or gland packing inaccordance with various API pipework plans. Oil‐lubricated bearings.ATEX‐compliant version available.Applications:Refineries, chemical and petrochemical industries, steel works, descalingunits, raw materials extraction, waste water management.Data for 50 Hz operation
Also suitable for 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000748
WKTRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
40 – 150max. 400max. 500
max. 51max. +200max. 3000
Description:Vertical can‐type ring‐section pump. Type VS6 to API 610 andDIN ISO 13709, multistage, first‐stage impeller designed as suctionimpeller, radial impellers. ATEX‐compliant version available.Applications:For pumping condensate and other NPSH‐critical products in industrialplants, particularly in refineries and petrochemical plants.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000875
Pumps
Pumps
40
Rainwater harvesting systems
Hya‐Rain / Hya‐Rain NRpQ [m3/h]H [m]p [bar]T [°C]
1max. 4
max. 43max. 6
max. +35
Description:Ready‐to‐connect package rainwater harvesting system in protectivehousing with automatic mains water back‐up function if the rainwaterstorage tank is empty, with integrated dry running protection anddemand‐driven automatic pump control. Hya‐Rain N version with analoglevel measurement in rainwater storage tank and integrated functionalcheck run.Applications:Rainwater and service water harvesting, irrigation and spray irrigationsystems.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000256
Hya‐Rain EcoRpQ [m3/h]H [m]p [bar]T [°C]
1max. 4
max. 43max. 6
max. +35
Description:Basic ready‐to‐connect package rainwater harvesting system withautomatic mains water back‐up function if the rainwater storage tank isempty, with integrated dry running protection and demand‐drivenautomatic pump control.Applications:Rainwater and service water harvesting, irrigation and spray irrigationsystems.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000600
Domestic water supply / swimming pools
Multi EcoRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1 – 1¼max. 8
max. 54max. 10
max. +50max. 2800
Description:Multistage self‐priming centrifugal pump in close‐coupled design.Applications:Single‐ or two‐family houses, agricultural facilities, spray irrigation,irrigation and washing plants, water supply and rainwater harvestingsystems.
Data for 50 Hz operation
Also available for 60 Hz
Controlmatic, Cervomatic http://shop.ksb.com/catalog/k0/en/product/ES000085
Multi Eco‐ProRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1 – 1¼max. 8
max. 54max. 10
max. +50max. 2800
Description:Multistage self‐priming centrifugal pump in close‐coupled design, withpower cable, plug and Controlmatic E automatic control unit starting andstopping the pump in line with consumer demand and protecting itagainst dry running. Automated with automatic control unit.Applications:Single‐ or two‐family houses, agricultural facilities, spray irrigation,irrigation and washing plants, water supply and rainwater harvestingsystems.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000253
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
41
Set 100DNQ [m3/h]H [m]T [°C]
100max. 6
max. 90max. +30
Description:Multistage centrifugal pump in shroud design made of stainless steel andplastic (S 100D) or in ring‐section design made of stainless steel(UPA 100C) for well diameters of 100 mm and above, complete with drive,control system and lead in box.Applications:Domestic water supply and general water supply, irrigation and sprayirrigation, drawdown of groundwater levels, fire protection, coolingcircuits, fountains, pressure booster and air‐conditioning systems.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000535
Multi Eco‐TopRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1 – 1¼max. 8
max. 54max. 7
max. +50max. 2800
Description:Multistage self‐priming centrifugal pump in close‐coupled design incl.accumulator with replaceable membrane in drinking water quality, totalvolume 20 or 50 litres, pressure switch for automatic pump operation and1.5‐metre power cable with plug.Applications:Single‐ or two‐family houses, agricultural facilities, spray irrigation,irrigation and washing plants, water supply and rainwater harvestingsystems. Multistage self‐priming centrifugal pump. Membrane‐typeaccumulator pressurised at the factory, with replaceable membrane.Pressure switch for automatic operation, factory‐set, pressure gauge.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000254
Movitec VMERpQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1½max. 9
max. 48max. 16
max. +60max. 2900
Description:Multistage vertical (horizontal installation upon request) high‐pressurecentrifugal pump with suction and discharge nozzles of identical nominaldiameters arranged opposite to each other (in‐line design).Applications:Single‐ or two‐family houses, agricultural facilities, spray irrigation,irrigation and washing plants, water supply and rainwater harvestingsystems. Pressure boosting, hot water and cooling water recirculation andfire‐fighting systems.
Data for 50 Hz operation
Also available for 60 Hz
PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000854
Ixo NRpQ [m3/h]H [m]T [°C]n [rpm]
1¼max. 8
max. 65max. +35
max. 2900
Description:Multistage close‐coupled centrifugal pump for fully or partly submergedoperation (min. immersion depth 0.1 m), with low‐level inlet, suctionstrainer with a max. mesh width of 2.0 mm.Applications:Water supply systems, spray irrigation, irrigation and washing plants,rainwater harvesting systems and water extraction from wells, reservoirsand rainwater storage tanks.
Data for 50 Hz operation
Switchgear, Cervomatic http://shop.ksb.com/catalog/k0/en/product/ES000007
Ixo‐ProRpQ [m3/h]H [m]T [°C]
1max. 3.9max. 60
max. +35
Description:Multistage submersible borehole pump with integrated pressure switch,flow sensor and lift check valve. Electronic dry running protection withfour consecutive start‐up attempts; integrated capacitor. 15‐metre H07RNF power cable with plug included.Applications:Rainwater harvesting, pressure boosting, water extraction and irrigation.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000896
Pumps
Pumps
42
Filtra NRpQ [m3/h]H [m]p [bar]T [°C]n [rpm]
2max. 36max. 21
max. 2.5max. +35
max. 2800
Description:Single‐stage self‐priming centrifugal pump in close‐coupled design.Applications:For pumping clean or slightly contaminated water, swimming pool waterwith a max. chlorine content of 0.3 %; ozonised swimming pool waterwith a max. salt content of 7 ‰.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000090
Pressure booster systems
Hya‐Solo EVRpQ [m3/h]H [m]p [bar]T [°C]
1¼ / 1½max. 6
max. 50max. 10
max. +60
Description:Fully automatic package pressure booster system with one vertical high‐pressure pump and continuously variable speed adjustment. Design andfunction as per DIN 1988‐500.Applications:Residential buildings, hospitals, office buildings, hotels, departmentstores, industry, etc.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000883
Hya‐Solo DRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 100max. 110max. 150
max. 16max. +70
Description:Fully automatic package single‐pump system with 8‐litre membrane‐typeaccumulator. The system is started and stopped as a function of pressure.Applications:Water supply systems for residential and office buildings, irrigation andspray irrigation, rainwater harvesting and service water supply systems intrade and industry.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000250
Hya‐Solo DSVRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 100max. 110max. 150
max. 16max. +70
Description:Fully automatic variable speed package single‐pump system withmagnetless high‐efficiency KSB SuPremE‐IE4 motor (to IEC/CD 60034‐30 Ed. 2) with PumpDrive. The system is started as a function ofpressure and stopped as a function of flow.Applications:Water supply systems for residential and office buildings, irrigation andspray irrigation, rainwater harvesting and service water supply systems intrade and industry.
Data for 50 Hz operation
KSB SuPremE, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000251
Hya‐Solo D FLRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 100max. 110max. 150
max. 16max. +70
Description:Fully automatic package single‐pump system. The system is started andstopped as a function of pressure. Design and function as per DIN 14462.Applications:Pressure boosting in fire protection systems to DIN 14462.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000709
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
43
Hya‐Duo D FLRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 100max. 110max. 150
max. 16max. +70
Description:Fully automatic package dual‐pump system consisting of one duty systemand one stand‐by system to ensure system redundancy. Design andfunction of both systems as per DIN 14462.Applications:Pressure boosting in fire protection systems to DIN 14462.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000710
Hya‐Solo D FL CompactRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 100max. 110max. 150
max. 16max. +70
Description:Fully automatic ready‐to‐connect break tank package booster set for firefighting, comprising a single‐pump system and break tank. The system isstarted and stopped as a function of pressure. Design and function as perDIN 14462.Applications:Fire‐fighting applications to DIN 14462.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000821
Hya‐Duo D FL CompactRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 100max. 110max. 150
max. 16max. +70
Description:Fully automatic, ready‐to‐connect break tank package booster set for firefighting, comprising a dual‐pump system and break tank. The system isstarted and stopped as a function of pressure. Design and function as perDIN 14462.Applications:Fire‐fighting applications to DIN 14462.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000820
Hya‐Compact KRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 40max. 10
max. 100max. 10
max. +40
Description:Fully automatic package pressure booster system with integrated stand‐bypump. Two vertical high‐pressure pumps in cascade operation, automatedwith BoosterControl Advanced. Two integrated pressure transmitters forthe suction and discharge side. With two standard volt‐free changeovercontacts for fault indication. Design and function as per DIN 1988‐500.Stationary floor‐mounted or wall‐mounted installation.Applications:Water supply systems for residential and office buildings, irrigation andspray irrigation, rainwater harvesting and service water supply systems intrade and industry.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000811
Hya‐Compact VPRp / DNQ [m3/h]H [m]p [bar]T [°C]
1¼ / 40max. 10
max. 100max. 10
max. +40
Description:Fully automatic package pressure booster system with integrated stand‐bypump. Two vertical high‐pressure pumps with continuously variable speedcontrol and BoosterControl Advanced. With two standard volt‐freechangeover contacts for fault indication. Design and function as perDIN 1988‐500. Stationary floor‐mounted or wall‐mounted installation.Applications:Water supply systems for residential and office buildings, irrigation andspray irrigation, rainwater harvesting and service water supply systems intrade and industry.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000811
Pumps
Pumps
44
Hya‐Eco VPRp / DNQ [m3/h]H [m]p [bar]T [°C]
2 / 80max. 70
max. 120max. 16
max. +70
Description:Fully automatic package pressure booster system, with either 2 or 3vertical high‐pressure pumps and continuously variable speed adjustmentof all pumps for fully electronic control of the required supply pressure,with two standard volt‐free changeover contacts for fault indication.Design and function as per DIN 1988‐500. Automated withBoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industry, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000596
Hyamat KRp / DNQ [m3/h]H [m]p [bar]T [°C]
1½ / 250max. 660max. 160
max. 16max. +70
Description:Fully automatic package pressure booster system, with 2 to 6 verticalhigh‐pressure pumps and fully electronic control to ensure the requiredsupply pressure, with volt‐free changeover contact for general faultindication and live‐zero monitoring of the connected sensors, design andfunction to DIN 1988‐5. Automated with BoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industry, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000247
Hyamat VRp / DNQ [m3/h]H [m]p [bar]T [°C]
1½ / 250max. 660max. 150
max. 16max. +70
Description:Fully automatic package pressure booster system with 2 to 6 vertical high‐pressure pumps and continuously variable speed adjustment of onepump; for fully electronic control of the required supply pressure. Designand function as per DIN 1988‐5. Automated with BoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industry, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000417
Hyamat SVPRp / DNQ [m3/h]H [m]p [bar]T [°C]
1½ / 250max. 660max. 150
max. 16max. +70
Description:Fully automatic package pressure booster system with 2 to 6 vertical high‐pressure pumps and continuously variable speed adjustment of all pumpsby PumpDrive; for fully electronic control of the required supply pressure.Design and function as per DIN 1988, Part 5. Automated withBoosterControl and PumpDrive.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industry, etc.
Data for 50 Hz operation
KSB SuPremE, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000418
Superbloc SBC.BRpQ [m3/h]H [m]p [bar]T [°C]
1½max. 12max. 95max. 10
max. +70
Description:Fully automatic package pressure booster system, with one pump and200‐litre membrane‐type accumulator. Pressure‐controlled starting andstopping.Applications:Water supply in small multiple dwelling buildings, spray irrigation,rainwater harvesting.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000432
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
45
Surpress Eco SE.2.BRp / DNQ [m3/h]H [m]p [bar]T [°C]
2 / 80max. 70
max. 100max. 16
max. +70
Description:Fully automatic package pressure booster system, with either 2 or 3vertical high‐pressure pumps, with fully electronic control to ensure therequired supply pressure, with standard volt‐free changeover contact forgeneral fault indication and live‐zero monitoring of the connectedsensors. Automated with BoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industrial plants, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000595
Surpress Eco SE.2.B VPRp / DNQ [m3/h]H [m]p [bar]T [°C]
2 / 80max. 70
max. 120max. 16
max. +70
Description:Fully automatic package pressure booster system with either 2 or 3vertical high‐pressure pumps. Continuously variable speed adjustment ofall pumps for fully electronic control of the required supply pressure, withtwo standard volt‐free changeover contacts for fault indication.Automated with BoosterControl and PumpDrive.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industrial plants, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000695
Surpresschrom SIC.2Rp / DNQ [m3/h]H [m]p [bar]T [°C]
1½ / 250max. 660max. 160
max. 16max. +70
Description:Fully automatic package pressure booster system, with 2 to 6 verticalhigh‐pressure pumps, with fully electronic control system ensuring therequired supply pressure, with standard volt‐free changeover contact forgeneral fault indication and live‐zero monitoring of the connectedsensors. Automated with BoosterControl.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industrial plants, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000700
Surpresschrom SIC.2 VRp / DNQ [m3/h]H [m]p [bar]T [°C]
1½ / 250max. 660max. 150
max. 16max. +70
Description:Fully automatic package pressure booster system with 2 to 6 vertical high‐pressure pumps. Continuously variable speed adjustment of one pumpwith PumpDrive for fully electronic control of the required supplypressure. Automated with BoosterControl and PumpDrive.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industrial plants, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000702
Surpresschrom SIC.2 SVPRp / DNQ [m3/h]H [m]p [bar]T [°C]
1½ / 250max. 660max. 150
max. 16max. +70
Description:Fully automatic package pressure booster system with 2 to 6 vertical high‐pressure pumps. Continuously variable speed adjustment of all pumpswith PumpDrive for fully electronic control of the required supplypressure. Automated with BoosterControl and PumpDrive.Applications:Pressure boosting in residential buildings, hospitals, office buildings,hotels, department stores, industrial plants, etc.
Data for 50 Hz operation
KSB SuPremE, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000701
Pumps
Pumps
46
Surpressbloc SBDNQ [m3/h]H [m]p [bar]T [°C]
100 – 200max. 640max. 160
max. 16max. +70
Description:Fully automatic package pressure booster system with two to four verticalhigh‐pressure pumps and fully electronic control system ensuring therequired supply. Automated with PLC.Applications:Industry and other applications. For handling service water and coolingwater not chemically or mechanically aggressive to the pump materials.Data for 50 Hz operation
Surpress Feu SFERpQ [m3/h]H [m]p [bar]T [°C]
2½max. 40max. 76max. 10
max. +70
Description:Fully automatic pressure booster system with two horizontal close‐coupled pumps (one pump on stand‐by duty). Design complies withAPSAD regulation R5. Pressure‐controlled starting and stopping.Automated with BoosterControl.Applications:Water supply and pressure boosting for wall hydrants, fire protection.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000441
Surpress SPRp / DNQ [m3/h]H [m]p [bar]T [°C]
1½ / 2max. 36max. 70max. 16
max. +70
Description:Fully automatic package pressure booster system with either two or threevertical high‐pressure pumps and fully electronic control unit ensuring therequired supply pressure at the consumer installations. Design andfunctions to EN 806‐2.Applications:Residential buildings, hospitals, office buildings, hotels, departmentstores, industrial plants, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000886
Surpress SP VPRp / DNQ [m3/h]H [m]p [bar]T [°C]
1½ / 2max. 36max. 70max. 16
max. +70
Description:Fully automatic package pressure booster system with either two or threevertical high‐pressure pumps. Continuously variable speed adjustment ofall pumps for fully electronic control of the required supply pressure atthe consumer installations. Design and function to DIN EN 806‐2 andDIN 1988‐500. Automated with BoosterControl.Applications:Residential buildings, hospitals, office buildings, hotels, departmentstores, industrial plants, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000892
Drainage pumps / waste water pumps
Ama‐Drainer N 301 – 358RpQ [m3/h]H [m]T [°C]
1¼ – 1½max. 16.5
max. 12max. +50
Description:Vertical single‐stage fully floodable submersible motor pump in close‐coupled design, IP68, with or without level control, max. immersiondepth: 2 m.Applications:Automatic drainage of pits, shafts, yards and cellars at risk of flooding,lowering of surface water levels, drainage, drainage of undergroundpassages, water extraction from rivers and reservoirs.
Data for 50 Hz operation
Also available for 60 Hz
Switchgear, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000771
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
47
Ama‐Drainer 4../5..RpQ [m3/h]H [m]T [°C]
1½ – 2max. 50max. 24
max. +40
Description:Vertical single‐stage fully floodable submersible motor pumps in close‐coupled design, IP68, with or without level control, max. immersiondepth: 7 m.Applications:Automatic drainage of pits, shafts, yards and cellars at risk of flooding,lowering of surface water levels, drainage, drainage of undergroundpassages, water extraction from rivers and reservoirs.
Data for 50 Hz operation
Also available for 60 Hz
Switchgear, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000078
Ama‐Drainer 80, 100Rp / DNQ [m3/h]H [m]T [°C]
2½ / 100max. 130
max. 26max. +50
Description:Vertical single‐stage fully floodable submersible motor pump in close‐coupled design, IP68, with or without level control, max. immersiondepth: 10 m.Applications:Automatic drainage of pits, shafts, yards and cellars at risk of flooding,lowering of surface water levels, drainage, drainage of undergroundpassages, water extraction from rivers and reservoirs.
Data for 50 Hz operation
Also available for 60 Hz
Switchgear, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000079
Ama‐Porter F / SDNQ [m3/h]H [m]T [°C]
50 – 65max. 40max. 21
max. +40
Description:Vertical single‐stage fully floodable submersible waste water pump inclose‐coupled design (grey cast iron variant), non‐explosion‐proof.Applications:Handling of all types of waste water, especially waste water containinglong fibres and solid substances, fluids containing gas/air, removing wastewater from flooded rooms or surfaces.
Data for 50 Hz operation
Switchgear, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000082
RotexRpQ [m3/h]H [m]Installation depth[m]T [°C]n [rpm]
1¼ – 2max. 24max. 14
max. 1.7max. +90
max. 2900
Description:Vertical single‐stage centrifugal pump with discharge to the top andparallel with the pump shaft, pump base designed to act as suctionstrainer. Pump and motor are rigidly connect by a support column.Supplied ready to be plugged in, with 1.5‐metre power cable and levelswitch.Applications:Automatic drainage of buildings, pits and tanks, lowering of surfacewater levels and drainage.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000012
MK / MKYRp / DNQ [m3/h]H [m]Installation depth[m]T [°C]n [rpm]
2 / 50max. 36max. 19
max. 2.8max. +200max. 3500
Description:Vertical submersible pump with three‐channel impeller, volute casingdesigned as inlet strainer.Applications:For pumping condensate and heat transfer liquids below boiling point,condensate return systems, primary and secondary heating circuits, fordirect installation in heating tanks or heat exchangers in the secondarycircuits of heat transfer systems (MKY).
Data for 50 Hz operation
Switchgear, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000013
Pumps
Pumps
48
Lifting units / pump stations
AmaDS³Q [m3/h]H [m]T [°C]
max. 200max. 85
depending onpump
Description:Waste water pump station with solids separation system. Indirecthydraulic transport of waste water, solids separators arranged upstreamof the pumps, for maximum economic efficiency, operating reliability andease of servicing.Applications:Municipal and industrial waste water transport. Applications with specialdrainage requirements, e.g. hotels, hospitals, campgrounds, etc.
Higher ratings possible upon request.
LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000858
Ama‐Drainer‐BoxDNQ [m3/h]H [m]T [°C]
40 – 50max. 46max. 24
max. +40
Description:Stable above‐floor plastic collecting tank or impact‐resistant underfloorplastic collecting tank, with floor drain and odour trap, both with Ama‐Drainer submersible motor pump starting and stopping automatically andswing check valve.Applications:Washbasins, showers, washing machines, garage driveways, basementsand rooms at risk of flooding, etc.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000262
Ama‐Drainer‐Box MiniDNQ [m3/h]H [m]T [°C]
40max.10
max. 6.5max. +35
Description:Reliable and compact waste water lifting unit in a modern design withactivated carbon filter meeting hygiene requirements and with showerconnection as standard. To EN 12050‐2.Applications:Automatic drainage of washbasins, showers, washing machines,dishwashers, etc. Use mini‐Compacta sewage lifting unit for handlingsewage from urinals and toilets!
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000862
Eva‐CleanRpQ [m3/h]H [m]T [°C]
1¼max. 8max. 7
max. +50
Description:Single‐piece water‐tight collecting tank made of PE‐HD, equipped withAma‐Drainer N submersible motor pump with integrated float switch.Applications:Disposal of domestic waste water from septic tanks and/or sand filters. Forpumping pre‐screened domestic waste water.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000712
mini‐CompactaDNQ [m3/h]H [m]T [°C]
32 – 100max. 36max. 25
max. +65
Description:Floodable single‐pump or dual‐pump sewage lifting unit for automaticdisposal of domestic sewage and faeces below the flood level.Applications:Basement flats, bars, basement party rooms and saunas, cinemas andtheatres, department stores, hospitals, hotels, restaurants or schools.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000261
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
49
CompactaDNQ [m3/h]H [m]T [°C]
80 – 100max. 140
max. 24max. +65
Description:Floodable single‐pump or dual‐pump sewage lifting unit for automaticdisposal of waste water and faeces below the flood level.Applications:Basement flats, bars, basement party rooms and saunas, cinemas andtheatres, department stores and hospitals, hotels, restaurants, schools,other public buildings, industrial facilities, underground train stations orfor joint sewage disposal from rows of houses.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000260
Kondensat‐LiftQ [m3/h]H [m]T [°C]
max. 0.34max. 4.5
max. +50
Description:Automatic condensate lifting unit.Applications:Fully automatic pumping of condensate generated below the flood levelby condensing boilers, air‐conditioning and cooling systems.Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000908
CK 800 Pump StationDNQ [m3/h]H [m]T [°C]
32 – 50max. 22max. 49
max. +40
Description:Ready‐to‐connect package single‐pump or dual‐pump station with PE‐LLD(polyethylene) collecting tank for buried installation. Equipped witheither one or two submersible waste water pumps of type Amarex N S(explosion‐proof or non‐explosion‐proof) or AmaPorter (non‐explosion‐proof). Tank design to DIN 1986‐100 and EN 752 / EN 476.Applications:Building and property drainage, waste water disposal, propertyrenovation, joint sewage disposal for multiple residential units, pumpeddrainage.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000778
Ama‐Porter CK Pump StationDNQ [m3/h]H [m]T [°C]
50 – 65max. 40max. 21
max. +40
Description:Ready‐to‐connect package single‐pump or dual‐pump station with PE‐LLD(polyethylene) collecting tank for buried installation. With either one ortwo non‐explosion‐proof Ama‐Porter submersible waste water pumps.Tank design to DIN 1986‐100 and EN 752 / EN 476. Automated with MSE/MSD switchgear or LevelControl Basic 2.Applications:Building and property drainage, waste water disposal, propertyrenovation, joint sewage disposal for multiple residential units, pumpeddrainage.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000498
Amarex N CK Pump StationDNQ [m3/h]H [m]T [°C]
50 – 65max. 50max. 39
max. +40
Description:Ready‐to‐connect package single‐pump or dual‐pump station with PE‐LLD(polyethylene) collecting tank for buried installation. Equipped witheither one or two Amarex N submersible waste water pumps, alsoavailable in explosion‐proof design. Tank design to DIN 1986‐100 andEN 752 / EN 476.Applications:Building and property drainage, waste water disposal, propertyrenovation, joint sewage disposal for multiple residential units, pumpeddrainage.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000266
Pumps
Pumps
50
Evamatic‐Box NDNQ [m3/h]H [m]T [°C]
50 – 65max. 40max. 21
max. +40
Description:Floodable lifting unit for domestic waste water, equipped with either oneor two pumps of type Ama‐Porter F (free‐flow impeller) or Ama‐Porter S(cutter).Applications:Disposal of domestic and municipal waste water occurring below theflood level.
Data for 50 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000430
SRPDNQ [m3/h]H [m]T [°C]
50 – 150max. 500
max. 68max. +40
Description:Ready‐to‐connect package single‐pump or dual‐pump station withfibreglass collecting tank for buried installation.Applications:Property renovation, disposal of domestic, municipal and industrial wastewater, joint sewage disposal for multiple residential units.
Switchgear http://shop.ksb.com/catalog/k0/en/product/ES000443
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
51
Submersible motor pumps
Amarex N S32DNQ [m3/h]H [m]T [°C]
32max. 16.5max. 29.5max. +40
Description:Vertical single‐stage submersible motor pump for wet installation,stationary or transportable version. Amarex N pumps are floodable,single‐stage, single‐entry close‐coupled pump sets which are not self‐priming. ATEX‐compliant version available.Applications:Amarex N S 32‐160 submersible motor pumps with cutter are used forpumping waste water in intermittent operation, domestic waste water,raw water, waste water containing faeces.
Data for 50 Hz operation
Switchgear, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000507
Amarex NDNQ [m3/h]H [m]T [°C]
50 – 100max. 190
max. 49max. +60
Description:Vertical single‐stage submersible motor pump for wet installation,stationary or transportable version. Amarex N pumps are floodable,single‐stage, single‐entry close‐coupled pump sets which are not self‐priming. ATEX‐compliant version available.Applications:For pumping all types of waste water, especially untreated waste watercontaining long fibres and solid substances, liquids containing gas or air,and raw, activated and digested sludge; for dewatering and waterextraction, drainage of rooms and areas at risk of flooding.
Data for 50 Hz operation
Also available for 60 Hz
Switchgear, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000507
Amarex KRTDNQ [m3/h]H [m]T [°C]n [rpm]
40 – 700max. 10080
max. 120max. +60
max. 2900
Description:Vertical single‐stage submersible motor pump in close‐coupled design,with various impeller types, for wet or dry installation, stationary ortransportable version. ATEX‐compliant version available.Applications:For pumping all types of abrasive or aggressive waste water in water andwaste water management, seawater desalination and industry, especiallyuntreated waste water containing long fibres and solid substances, fluidscontaining gas or air, and raw, activated and digested sludge.
Data for 50 Hz operation
Also available for 60 Hz
Amacontrol, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000092
Amarex KRT, dry‐installed, jacket‐cooledDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
100 – 700max. 10080
max. 120max. 10
max. +40max. 1450
Description:Vertical single‐stage submersible motor pump in close‐coupled design,various impeller types, for dry installation.Applications:For pumping all types of waste water in waste water management andindustry, especially untreated waste water containing long fibres andsolid substances, fluids containing gas or air, and raw, activated anddigested sludge.Data for 50 Hz operation
Also available for 60 Hz
Amacontrol, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000092
Amarex KRT, wet‐/dry‐installed, with energy‐saving motorDNQ [m3/h]H [m]T [°C]n [rpm]
80 – 200max. 550
max. 25max. +40
max. 1450
Description:Horizontal or vertical single‐stage submersible motor pump in close‐coupled design, with various impeller types, for wet or dry installation,stationary or transportable version, with energy‐saving motor.Applications:For pumping all types of waste water in waste water management andindustry, especially untreated waste water containing long fibres andsolid substances, fluids containing gas or air, and raw, activated anddigested sludge.
Data for 50 Hz operation
Also available for 60 Hz
Amacontrol, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000092
Pumps
Pumps
52
Submersible pumps in discharge tubes
Amacan KDNQ [m3/h]H [m]T [°C]n [rpm]
700 – 1400max. 7200
max. 30max. +40max. 980
Description:Wet‐installed submersible motor pump for installation in discharge tubes,with channel impeller, single‐stage, single‐entry. ATEX‐compliant versionavailable.Applications:For handling pre‐cleaned chemically neutral waste water, industrialeffluent, sewage, fluids not containing any stringy substances, pre‐treatedby screens and overflow sills; as waste water, mixed sewage and activatedsludge pumps in waste water treatment plants, irrigation and drainagepumping stations.
Data for 50 Hz operation
Also available for 60 Hz
Amacontrol http://shop.ksb.com/catalog/k0/en/product/ES000100
Amacan PDNQ [m3/h]H [m]T [°C]n [rpm]
500 – 1500max. 25200
max. 12max. +40
max. 1450
Description:Wet‐installed submersible motor pump for installation in discharge tubes,with axial propeller in ECB design, single‐stage, single‐entry. ATEX‐compliant version available.Applications:Irrigation and drainage pumping stations, for stormwater transport instormwater pumping stations, raw and clean water transport in waterand waste water treatment plants, cooling water transport in powerstations and industrial plants, industrial water supply, water pollution andflood control, aquaculture.
Data for 50 Hz operation
Also available for 60 Hz
Amacontrol http://shop.ksb.com/catalog/k0/en/product/ES000099
Amacan SDNQ [m3/h]H [m]T [°C]n [rpm]
650 – 1300max. 10800
max. 40max. +30
max. 1450
Description:Wet‐installed submersible motor pump for installation in discharge tubes,with mixed flow impeller, single‐stage. ATEX‐compliant version available.Applications:For pumping water not containing stringy material in irrigation anddrainage pumping stations, general water supply systems, water pollutionand flood control.Data for 50 Hz operation
Also available for 60 Hz
Amacontrol http://shop.ksb.com/catalog/k0/en/product/ES000101
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
53
Mixers / agitators / tank cleaning units
AmamixPropeller Ø [mm]Installation depth[m]T [°C]n [rpm]
200 – 600max. 30
max. +40max. 1400
Description:Horizontal submersible mixer with self‐cleaning ECB propeller, close‐coupled design, direct drive. ATEX‐compliant version available.Applications:For handling municipal and industrial waste water and sludges inenvironmental engineering (also in biogas plants).
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000268
AmapropPropeller Ø [mm]Installation depth[m]T [°C]n [rpm]
1000 – 2500max. 30
max. +40max. 109
Description:Horizontal submersible mixer with self‐cleaning ECB propeller, close‐coupled design, with coaxial spur gear drive. ATEX‐compliant versionavailable.Applications:Environmental engineering, particularly for handling municipal andindustrial waste water and sludges. For circulating, keeping in suspensionand inducing flow in nitrification and denitrification tanks, activatedsludge tanks, mixing tanks, final storage tanks, biological phosphateelimination tanks, flocculation tanks and in biogas applications.
http://shop.ksb.com/catalog/k0/en/product/ES000271
AmajetDNQ [m3/h]T [°C]n [rpm]
100 – 150max. 195max. +40
max. 1450
Description:Stationary or portable unit with horizontally or vertically mountedsubmersible propulsive jet pump with non‐clogging free‐flow impeller.Motor ratings of 5.5 to 27 kW. Available variants: Amajet, SewerAmajet,SwingAmajet, MultiAmajet.Applications:For cleaning stormwater tanks and storage sewers.
http://shop.ksb.com/catalog/k0/en/product/ES000097
AmalineDNQ [m3/h]H [m]T [°C]n [rpm]
300 – 800max. 5400
max. 2max. +40max. 960
Description:Wet‐installed horizontal propeller pump with submersible motor,equipped with direct drive or spur gear, ECB propeller with three rigid,fibre‐repellent blades, bolt‐free connection to the discharge pipe. ATEX‐compliant version available.Applications:For recirculating activated sludge in waste water treatment systems.
http://shop.ksb.com/catalog/k0/en/product/ES000273
Pumps
Pumps
54
Pumps for solids‐laden fluids
SewatecDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
50 – 700max. 10000
max. 115max. 10
max. +70max. 2900
Description:Volute casing pump for horizontal or vertical installation, with free‐flow (F), single‐channel (E), multi‐channel (K) or diagonal single‐vaneimpeller (D), discharge flange to DIN and ANSI standards. ATEX‐compliantversion available.Applications:For pumping untreated sewage and all types of waste water in wastewater management and industry.Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000068
SewablocDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
50 – 200max. 1000
max. 80max. 10
max. +70max. 2900
Description:Close‐coupled volute casing pump for horizontal or vertical installation,with free‐flow (F), multi‐channel (K) or diagonal single‐vane impeller (D),discharge flange to DIN and ANSI standards. ATEX‐compliant versionavailable.Applications:For pumping untreated sewage and all types of waste water in wastewater management and industry.Data for 50 Hz operation
Also available for 60 Hz
PumpDrive, LevelControl http://shop.ksb.com/catalog/k0/en/product/ES000069
KWP / KWP‐BlocDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
40 – 900max. 15000
max. 100max. 10
‐40 to +120max. 2900
Description:Horizontal radially split volute casing pump in close‐coupled or back pull‐out design, single‐stage, single‐entry, available with various impellertypes: channel impeller, open multi‐channel impeller and free‐flowimpeller. ATEX‐compliant version available.Applications:For pumping pre‐treated sewage, waste water, all types of slurrieswithout stringy material and pulps up to 5 % bone dry with a maximumdensity of 1.4 kg/dm³.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000018
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
55
Slurry pumps
WBCQ [m3/h]H [m]p [bar]T [°C]
max. 13600max. 80max. 40
max. +120
Description:Patented design with state‐of‐the‐art hydraulic and wear technologies forhigh‐pressure applications. The pump casing is designed to withstandmaximum stresses, e.g. during pressure surges.Applications:Ideal for the single‐stage or multistage transport of ore and tailings andfor dredging.
http://shop.ksb.com/catalog/k0/en/product/ES000227
LSA‐SQ [m3/h]H [m]p [bar]T [°C]
max. 14000max. 90max. 16
max. +120
Description:Premium design white cast iron pump for long service life handling severeslurries. The maintenance‐friendly single‐wall construction and heavysection white cast iron wetted end combined with the cartridge bearingassembly provides maximum reliability and ease of maintenance.Applications:Ore and tailings transport, cyclone feed, dredging (dry‐installed orsubmerged operation) and industrial processes.
http://shop.ksb.com/catalog/k0/en/product/ES000220
LCC‐MQ [m3/h]H [m]p [bar]T [°C]
max. 3865max. 90max. 16
max. +120
Description:The wetted pump end (casing, impeller and suction plate / liner) is madeof white cast iron. Design optimised to permit easy dismantling andreassembly for maintenance and inspections.Applications:Reliable pump for high heads and moderately corrosive slurries. Used inmine dewatering, ash and tailings transport and dredging.
http://shop.ksb.com/catalog/k0/en/product/ES000217
LCC‐RQ [m3/h]H [m]p [bar]T [°C]
max. 3865max. 90max. 16
max. +120
Description:Interchangeable rubber‐lined or part‐metal design allows adaptation ofexisting pumps to new applications by simply exchanging the wettedpump end.Applications:The pumps are suitable for moderate heads, fine particles and highlycorrosive slurries.
http://shop.ksb.com/catalog/k0/en/product/ES000218
TBCQ [m3/h]H [m]p [bar]T [°C]
max. 18200max. 90max. 55
max. +120
Description:Horizontal high‐pressure end‐suction centrifugal pump offering maximumresistance to wear and ease of maintenance. The conventional single‐walldesign transfers stress loads from the wear plates to the casing covers inhigh‐pressure applications. Pump components made of highly wear‐resistant white cast iron.Applications:High‐head high‐flow hydrotransport of tailings, dredged material,pipeline booster stations and other severe duties.
http://shop.ksb.com/catalog/k0/en/product/ES000226
Pumps
Pumps
56
LCVQ [m3/h]H [m]p [bar]T [°C]
max. 1360max. 38max. 14
max. +120
Description:Rugged vertical shaft submersible pump with casing, impeller and suctionplate / liner made of white cast iron, bearing assembly located out ofproduct. Replaceable wetted parts made of white cast iron or naturalrubber.Applications:Particularly suitable for use in industrial processes and for transportingtailings in mines and pits.
http://shop.ksb.com/catalog/k0/en/product/ES000016
FGDQ [m3/h]H [m]p [bar]T [°C]
max. 22700max. 45max. 17
max. +120
Description:High‐flow / low‐head white cast iron pump with single‐wall casing andhigh‐efficiency impeller. Single‐piece suction cover with integratedmounting plate.Applications:Flue gas desulpurisation systems and process circuits.
http://shop.ksb.com/catalog/k0/en/product/ES000231
MegaQ [m3/h]H [m]p [bar]T [°C]
max. 45max. 30max. 24
max. +120
Description:Horizontal end‐suction volute casing pump with open three‐vane impellerfor handling solids‐laden liquids.Applications:Low‐volume hydrotransport of solids‐laden liquids and abrasive slurries.
http://shop.ksb.com/catalog/k0/en/product/ES000229
MHDQ [m3/h]H [m]p [bar]T [°C]
max. 32000max. 80max. 28
max. +120
Description:Horizontal volute casing pump for high‐volume hydrotransport of solids.For pumping slurries of large and very large particle sizes with a verygood suction behaviour and high efficiency. Pump components made ofwhite cast iron.Applications:Ideal for pipeline pressure booster stations and severe mining duties.Highly suitable for loading and unloading duties on (cutter) suctiondredgers.
http://shop.ksb.com/catalog/k0/en/product/ES000224
LHDQ [m3/h]H [m]p [bar]T [°C]
max. 21600max. 65max. 17
max. +120
Description:Horizontal volute casing pump for high‐volume hydrotransport of solids.For pumping slurries of large and very large particle sizes with a verygood suction behaviour and high efficiency. Used in low‐pressureapplications. Pump components made of white cast iron.Applications:Ideal for handling sand and gravel, on dredgers for land reclamation andas booster pumps.
http://shop.ksb.com/catalog/k0/en/product/ES000223
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
57
MDXQ [m3/h]H [m]p [bar]T [°C]
max. 14000max. 90max. 16
max. +120
Description:Pump designed with the latest technology from GIW. Superior wearproperties and extremely long service life handling aggressive slurries.Applications:Designed for SAG and ball mill discharge duties, cyclone feed, screen feedand other ore mining and treatment processes.
http://shop.ksb.com/catalog/k0/en/product/ES000850
ZWQ [m3/h]H [m]p [bar]T [°C]
max. 400max. 35max. 10
max. +120
Description:Rugged vertical shaft submersible pump with casing, impeller and suctioncover made of white cast iron, top and bottom impeller inlet. Bearingsnot exposed to fluid handled. Replaceable wetted components.Applications:Particularly suitable for pumping abrasive slurries, dewatering, floorclean‐up and process applications.
http://shop.ksb.com/catalog/k0/en/product/ES000852
HVFQ [m3/h]H [m]p [bar]T [°C]
max. 400max. 35max. 10
max. +120
Description:The pump provides continuous operation without shutdown or operatorintervention. The new hydraulic design removes air from the impeller eyewhile the pump is running, and the pump can be retrofitted into anyexisting operation.Applications:For use in all froth pumping applications in the mineral processing andindustrial minerals industries.
http://shop.ksb.com/catalog/k0/en/product/ES000851
Pumps
Pumps
58
Self‐priming pumps
Etaprime LDNQ [m3/h]H [m]p [bar]T [°C]
25 – 125max. 180
max. 85max. 10
max. +90
Description:Horizontal self‐priming volute casing pump in back pull‐out design,single‐stage, with open multi‐vane impeller, long‐coupled. ATEX‐compliant version available.Applications:For pumping clean, contaminated or aggressive liquids not containingabrasive or solid substances.Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000120
Etaprime B / BNDNQ [m3/h]H [m]p [bar]T [°C]
25 – 100max. 130
max. 72max. 10
max. +90
Description:Horizontal self‐priming volute casing pumps, single‐stage, with openmulti‐vane impeller, close‐coupled, pump shaft and motor shaft rigidlyconnected (BN). ATEX‐compliant version available.Applications:For pumping clean, contaminated or aggressive liquids not containingabrasive or solid substances.Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000119
MZDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
20 – 50max. 21
max. 140max. 16
‐5 to +120max. 1500
Description:Self‐priming multistage liquid ring pump in close‐coupled design, withmechanical seal or gland packing.Applications:Boiler feed, sanitary hot water, hydrophore systems for fresh or seawaterand fresh water pre‐heating.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000754
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
59
Submersible borehole pumps
S 100DDNQ [m3/h]H [m]T [°C]
100max. 16
max. 300max. +30
Description:Multistage centrifugal pump in shroud design made of stainless steel andplastic for well diameters of 100 mm (4 inches) and above, available withsingle‐phase AC motor or three‐phase motor with motor lead.Applications:Domestic water supply, irrigation and spray irrigation, drawdown ofgroundwater levels, in fire‐fighting systems, cooling circuits, fountains,pressure booster and air‐conditioning systems.
Data for 50 Hz operation
Also available for 60 Hz
Switchgear, Cervomatic http://shop.ksb.com/catalog/k0/en/product/ES000563
UPA 100CDNQ [m3/h]H [m]T [°C]
100max. 15
max. 400max. +30
Description:Multistage centrifugal pump in ring‐section design made of stainless steelfor well diameters of 100 mm (4 inches) and above, available with single‐phase AC motor or three‐phase motor with motor lead.Applications:Domestic water supply, irrigation and spray irrigation, drawdown ofgroundwater levels, in fire‐fighting systems, cooling circuits, fountains,pressure booster and air‐conditioning systems. UPA 100C is also suitablefor drinking water applications to ACS.
Data for 50 Hz operation
Also available for 60 Hz
Switchgear, Cervomatic http://shop.ksb.com/catalog/k0/en/product/ES000003
UPA 150CDNQ [m3/h]H [m]T [°C]
150max. 79
max. 440max. +50
Description:All‐stainless steel single‐stage or multistage centrifugal pump in ring‐section design for well diameters of 150 mm (6 inches) and above.Applications:For pumping clean or slightly contaminated water, irrigation anddrainage, spray irrigation, industrial and municipal water supply,drawdown and maintenance of groundwater levels, fire fighting, supplyof drinking, raw and service water, pressure boosting.
Data for 50 Hz operation
Also available for 60 Hz
PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000003
UPA 200, 200B, 250CDNQ [m3/h]H [m]T [°C]
200 – 250max. 330max. 460max. +50
Description:Single‐stage or multistage single‐entry centrifugal pump in ring‐sectiondesign for vertical or horizontal installation. Optionally available with liftcheck valve or connection branch.Applications:For pumping clean or slightly contaminated water in general watersupply, spray irrigation and irrigation, drawdown and maintenance ofgroundwater levels, fountains and pressure booster systems, mining, fire‐fighting systems, emergency water supply, etc.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000003
UPA 300, 350DNQ [m3/h]H [m]T [°C]
300 – 350max. 840max. 480max. +50
Description:Single‐stage or multistage single‐entry centrifugal pump in ring‐sectiondesign for vertical or horizontal installation. Mixed flow hydraulic systemswith impellers that can be turned down. Optionally available with liftcheck valve or connection branch.Applications:For pumping clean or slightly contaminated water in general watersupply, spray irrigation and irrigation, drawdown and maintenance ofgroundwater levels, mining, fountains and fire‐fighting systems, etc.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000003
Pumps
Pumps
60
UPZ, BSX‐BSFDNQ [m3/h]H [m]T [°C]
> 350max. 2200max. 1500max. +50
Description:Single‐stage or multistage single‐entry (BSX‐BSF) or double‐entry (UPZ)centrifugal pump in ring‐section design for vertical or horizontalinstallation.Applications:For pumping clean or slightly contaminated water, for drawdown andmaintenance of groundwater levels, in mining.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000511
Deep‐well turbine pumps
BEVDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
80 – 400max. 2200
max. 350max. 40
+5 to +75max. 3000
Description:Multistage deep‐well turbine pump with closed impellers, column sectionwith bearing assembly, shaft sleeve, shaft sealed by gland packing, drivenby electric motor or diesel engine. ATEX‐compliant version available.Applications:For pumping clean water in agriculture, collection and irrigation, publicwater supply, industry, fire‐fighting systems, etc.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000716
High‐pressure pumps, fixed / variable speed
MovitecRp / DNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1 – 2 / 25 – 100max. 113max. 401
max. 40max. +140max. 2900
Description:Multistage vertical high‐pressure centrifugal pump in ring‐section designwith suction and discharge nozzles of identical nominal diametersarranged opposite to each other (in‐line design), close‐coupled. ATEX‐compliant version available.Applications:Spray irrigation, irrigation, washing, water treatment, fire‐fighting andpressure booster systems, hot water and cooling water recirculation,boiler feed systems, etc.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive, PumpMeter
Movitec VCIRp / DNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
1¼ – 2 / 32 – 45max. 27
max. 250max. 40
max. +120max. 2900
Description:Multistage vertical high‐pressure immersion pump for installation ontanks or platforms.Applications:Machine tools, industrial machine systems, condensate transport, paintshops.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000870
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
61
Multitec / Multitec‐RODNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
32 – 150max. 850
max. 1000max. 100
‐10 to +200max. 3500
Description:Multistage centrifugal pump in ring‐section design. Horizontal installationin long‐coupled or close‐coupled design. Vertical installation in close‐coupled design or with cardan shaft. With either one or two rollerbearings. Axial or radial suction nozzle, radial discharge nozzle. Radialsuction and discharge nozzles can be turned in steps of 90°. Cast radialimpeller. Casing materials: grey cast iron, steel, stainless steel, duplexstainless steel, super duplex stainless steel. Hydraulic system materials:grey cast iron, bronze, stainless steel, duplex stainless steel, super duplexstainless steel. ATEX‐compliant version available.Applications:Water and drinking water supply systems, industry, pressure boostersystems, irrigation systems, power stations, heating, filter, fire‐fighting,reverse osmosis and snow‐making systems, washing plants, etc.
Data for 50 Hz and 60 Hz operation
KSB SuPremE, PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000214
Axially split pumps
OmegaDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
80 – 350max. 2880
max. 210max. 25
max. +140max. 3500
Description:Single‐stage axially split volute casing pump for horizontal or verticalinstallation, with double‐entry radial impeller, mating flanges to DIN, ENor ASME.Applications:For pumping water with a low solids content, e.g. in waterworks,irrigation and drainage pumping stations, extraction duties indesalination systems, power stations, fire‐fighting systems, shipbuilding,district heating or cooling.
Data for 50 Hz and 60 Hz operation
Higher ratings possible upon request.
PumpDrive, PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000071
RDLODNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
350 – 700max. 10000
max. 240max. 25
max. +140max. 1800
Description:Single‐stage axially split volute casing pump for horizontal or verticalinstallation, with double‐entry radial impeller, mating flanges to DIN, ENor ASME.Applications:For pumping water with a low solids content, e.g. in waterworks,irrigation and drainage pumping stations, extraction duties indesalination systems, power stations, fire‐fighting systems, shipbuilding,district heating or cooling.
Data for 50 Hz and 60 Hz operation
Higher ratings possible upon request.
PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000170
RDLPDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
350 – 1200max. 18000
max. 550max. 64
max. +80max. 1800
Description:Axially split volute casing pump for horizontal installation, with one, twoor three stages and double‐entry radial impeller, mating flanges to DIN,ISO or ANSI.Applications:For pumping water with a low solids content, e.g. in waterworks andlong‐distance water supply.
Data for 50 Hz and 60 Hz operation
Higher ratings possible upon request.
PumpMeter http://shop.ksb.com/catalog/k0/en/product/ES000171
Pumps
Pumps
62
Hygienic pumps
VitachromDNQ [m3/h]H [m]p [bar]T [°C]
50 – 125max. 340max. 100
max. 12max. +140
Description:Vitachrom is a service‐friendly non‐priming close‐coupled single‐stagehygienic pump in back pull‐out design. The pump features a semi‐openimpeller and electropolished surfaces. It is very easy to clean by CIP/SIPthanks to its almost complete lack of dead volume or narrow clearances.Its wetted components are made of 1.4404 / 1.4409 (AISI 316L / CF3M)stainless steel. Vitachrom is EHEDG‐certified and all materials comply withFDA standards and EN 1935/2004. ATEX‐compliant version available.Applications:Hygienic handling of fluids in the food, beverage and pharmaceuticalindustries and in the chemical industry.
Data for 50 Hz operation
Also available for 60 Hz
KSB SuPremE, PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000030
VitacastDNQ [m3/h]H [m]p [bar]T [°C]
25 – 150max. 560max. 100
max. 10max. +140
Description:Vitacast is a service‐friendly volute casing pump with standardised motor;all wetted components are made of 1.4404 / 1.4409 (AISI 316L / CF3M)stainless steel. Designed with very little dead volume; open impeller,electropolished surface, excellent efficiency. Hygienic design for thehighest requirements on cleanability (CIP/SIP‐compatible), certified by theTNO Nutrition and Food Research Institute to EHEDG standards, allmaterials comply with FDA standards and EN 1935/2004. Trolley availableamong other accessories. ATEX‐compliant version available.Applications:Hygienic handling of fluids in the food, beverage and pharmaceuticalindustries and in the chemical industry.
Data for 50 Hz operation
Also available for 60 Hz
Other ratings possible on request
PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000785
VitaprimeDNQ [m3/h]H [m]p [bar]T [°C]
40 – 80max. 55max. 45max.10
max. +140
Description:Vitaprime is a service‐friendly self‐priming side channel pump in close‐coupled design with standardised motor; all wetted components aremade of 1.4404 / 1.4409 (AISI 316L / CF3M) stainless steel. Hygienic designfor the highest requirements of cleanability (CIP/SIP‐compatible). Allmaterials comply with FDA standards. ATEX‐compliant version available.Trolley also available among other accessories.Applications:Hygienic handling of fluids in the food, beverage and pharmaceuticalindustries and in the chemical industry.
Data for 50 Hz operation
Also available for 60 Hz
Other ratings possible on request
PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000787
VitastageQ [m3/h]H [m]p [bar]T [°C]
max. 40max. 150
max. 16max. +140
Description:Vitastage is a multistage centrifugal pump in close‐coupled design forvertical or horizontal installation. All wetted components are made of1.4401 / 1.4408 (AISI 316 / CF8M) stainless steel. Versatile, robust andespecially energy‐efficient. CIP/SIP‐compatible. All materials comply withFDA standards and EN 1935/2004. Trolley also available among otheraccessories.Applications:Processes with moderate hygienic requirements in the food and beverageindustries and in the chemical industry.
Data for 50 Hz operation
Also available for 60 Hz
Other ratings possible on request
PumpDrive http://shop.ksb.com/catalog/k0/en/product/ES000788
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
63
VitalobeDNQ [m3/h]H [m]p [bar]T [°C]Viscosity [cP]
25 – 200 (1"– 8")max. 300max. 200
max. 30‐40 to +200
max. 200000
Description:Vitalobe is a sturdy rotary lobe pump in hygienic design, bi‐directionaloperation possible, horizontal or vertical orientation of connections.Hygienic design, highly CIP/SIP‐compatible due to its almost complete lackof dead volume or narrow clearances. All wetted components made of1.4404 / 1.4409 (AISI 316L / CF3M) stainless steel; various rotor types, shaftseals and process connections available. Installed as a pump set withgeared standardised motor. Vitalobe is EHEDG‐certified and all materialscomply with FDA standards and EN 1935/2004. ATEX‐compliant versionavailable. Accessories include trolley, heatable casing or casing cover andoverpressure protection unit.Applications:Hygienic and gentle handling of sensitive or high‐viscosity fluids in thefood, beverage and pharmaceutical industries, the chemical industry andgeneral process engineering.
Data for 50 Hz operation
Also available for 60 Hz
Other ratings possible on request
Frequency inverter http://shop.ksb.com/catalog/k0/en/product/ES000847
Pumps for power station conventional islands
CHTA / CHTC / CHTDDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
100 – 500max. 3700max. 5300
max. 560max. +210max. 6750
Description:Horizontal high‐pressure barrel‐type pumps with radial impellers, single‐entry and double‐entry, multistage, with flanges or weld end nozzles toDIN and ANSI.Applications:For pumping feed water and condensate in power stations and industrialplants, generation of pressurised water for bark peeling and descalingunits.Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000239
HGB / HGC / HGDDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
40 – 400max. 2300max. 5300
max. 560max. +210max. 7000
Description:Horizontal radially split ring‐section pump with radial impellers, single‐entry or double‐entry, multistage.Applications:For pumping feed water and condensate in power stations and industrialplants, pressurised water generation for bark peeling and descaling units,snow guns, etc.
Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000233
HGMDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
25 – 100max. 274
max. 1400max. 140
max. +160max. 3600
Description:Horizontal radially split product‐lubricated multistage ring‐section pumpwith radial impellers, axial and radial single‐entry inlet.Applications:For pumping feed water in power stations, boiler feed systems andcondensate transport in industrial plants.
Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000236
Pumps
Pumps
64
YNKDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
125 – 600max. 4500
max. 370max. 40
max. +210max. 1800
Description:Horizontal radially split single‐stage double‐entry boiler feed boosterpump (booster system) with cast steel single or double volute casing.Applications:For pumping feed water in power stations and industrial plants.
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000181
LUV / LUVADNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
100 – 550max. 7000
max. 300max. 350
max. +380max. 3600
Description:Vertical spherical casing pump, radial impellers, single‐entry, single‐ tothree‐stage. Suitable for very high inlet pressures and temperatures.Integrated wet winding motor to VDE. Product‐lubricated bearings, noneed for oil supply systems. Design to TRD, ASME or IBR.Applications:Hot water recirculation in forced‐circulation, forced‐flow and combined‐circulation boilers for very high pressures and in solar power towers.Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000183
WKTBDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
150 – 300max. 1500
max. 370max. 40
max. +1401500
Description:Vertical can‐type ring‐section pump, underfloor installation on baseframe, multistage, first‐stage impeller designed as a double‐entry suctionimpeller, radial impellers. Flanges to DIN or ANSI.Applications:For pumping condensate in power stations and industrial plants.
Data for 50 Hz operation
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000506
SEZ / SEZT / PHZ / PNZQ [m3/h]H [m]T [°C]n [rpm]
max. 80000max. 120max. +40max. 980
Description:Vertical tubular casing pump with open mixed flow impeller (SEZ), mixedflow propeller (PHZ) or axial propeller (PNZ), pump inlet with bellmouthor suction elbow, pull‐out design available, discharge nozzle arrangedabove or below floor level, flanges to DIN or ANSI standards available.Applications:For pumping raw, clean, service and cooling water in industry, watersupply systems, power stations and seawater desalination plants.
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000173
SNW / PNWDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
350 – 800max. 9000
max. 50max. 10
max. +60max. 1500
Description:Vertical tubular casing pump with mixed flow impeller (SNW) or axialpropeller (PNW), single‐stage, with maintenance‐free Residur® bearings,discharge nozzle arranged above or below floor level.Applications:Irrigation and drainage systems, stormwater pumping stations, pumpingraw and clean water, water supply, cooling water.
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000176
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
65
BeveronQ [m3/h]H [m]
max. 30max. 27
Description:Concrete volute casing pump with mixed flow impeller, single‐stage, withzero‐maintenance lubricant‐free Residur bearings.Applications:Coast protection and flood control, irrigation and drainage, low‐liftpumping stations, reservoir filling, stormwater applications, coolingwater, raw and clean water.
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000868
SPYDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
350 – 1200max. 21600
max. 50max. 10
max. +105max. 1480
Description:Long‐coupled volute casing pump, single‐stage, in back pull‐out design.Applications:Irrigation, drainage and water supply systems, for pumping condensate,cooling water, service water, etc.
Data for 50 Hz operation
Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000422
Pumps for nuclear power stations
RERDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
max. 800max. 40000
max. 140max. 175
max. +350max. 1800
Description:Vertical single‐stage reactor coolant pump RCP with forged circular casingplated on the inside, with diffuser; either with integrated pump thrustbearing or shaft supported by motor bearing.Applications:Reactor coolant recirculation in nuclear power stations.
Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000144
RSRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
max. 750max. 24000
max. 215max. 175
max. +350max. 1800
Description:Vertical single‐stage reactor coolant pump RCP with cast casing, shaftsupported by motor bearing.Applications:Reactor coolant recirculation in nuclear power stations.
Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000146
RUVDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
max. 650max. 22000
max.111max. 155
max. +350max. 1800
Description:Vertical single‐stage reactor coolant pump RCP. Seal‐less design withintegrated wet rotor motor and integrated flywheel. Product‐lubricatedbearings, no oil supply systems required.Applications:Reactor coolant recirculation in generation III+ nuclear power stations.
Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000848
Pumps
Pumps
66
PSRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
max. 600max. 9000
max. 45max. 75
max. +300max. 2000
Description:Vertical pump set integrated in the reactor containment floor, seal‐lesspump with leak‐free, low‐maintenance wet rotor motor.Applications:Reactor coolant recirculation in boiling water reactors.
Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000150
RHDDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
125 – 500max. 6500max. 1000
max. 150max. +210max. 6500
Description:Horizontal single‐stage double‐entry main feed water pump MFWP, castor forged variant.Applications:Main feed water supply (MFWS) in steam generation systems of nuclearpower stations.
Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000138
LUV NuclearDNQ [m3/h]H [m]p [bar]T [°C]
40 – 600max. 7000
max. 300max. 320
max. +430
Description:Vertical pump with integrated motor, single‐entry, single‐ to three‐stage.Suitable for very high inlet pressures and temperatures. Integrated wetwinding motor to VDE. Product‐lubricated bearings, no oil supply systemsrequired. Design to ASME Section 3, KTA, etc.Applications:As reactor water clean‐up pump in boiling water reactors, reactor coolantpump in boiling water and pressurised water reactors and recirculationpump in test facilities.
Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000855
RHMDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
max. 150max. 300
max. 2100max. 220
max. +180max. 8000
Description:Horizontal multistage barrel pull‐out pump.Applications:Core flooding, emergency cooling and residual heat removal systemsRHRS, chemical and volume control systems CVCS, control rod drivesystems CRDS, high‐pressure and medium‐pressure safety injection systemsHPSI / LPSI / MHSI / LHSI, emergency feed water systems EFWS, start‐upand shutdown feed water systems SSS, high‐pressure charging.Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000245
RVMDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
max. 85max. 50
max. 2000max. 200
max. +100max. 6000
Description:Vertical multistage barrel pull‐out pump.Applications:Core flooding, emergency cooling and residual heat removal systemsRHRS, chemical and volume control systems CVCS, high‐pressure andmedium‐pressure safety injection systems HPSI / LPSI / MHSI / LHSI.
Available for 50 Hz and 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000243
Not available for worldwide sale Factory‐automated Automation possible
Pumps
Pumps
67
RHRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
max. 500max. 6000
max. 190max. 63
max. +200max. 3600
Description:Horizontal annular casing pump with forged or cast pressure boundaryand diffuser.Applications:Core flooding, emergency cooling and residual heat removal systemsRHRS, ancillary systems, acid feed system and low‐pressure injectionsystem LPSI, component cooling water systems CCWS.
Available for 50 Hz and 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000140
RVRDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
max. 500max. 6000
max. 190max. 63
max. +200max. 3600
Description:Vertical annular casing pump with forged or cast pressure boundary anddiffuser.Applications:Core flooding, emergency cooling and residual heat removal systemsRHRS, ancillary systems, acid feed system and low‐pressure injectionsystem LPSI, component cooling water system CCWS.
Available for 50 Hz and 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000142
Pumps for desalination by reverse osmosis
RPH‐RODNQ [m3/h]H [m]p [bar]T [°C]
100 – 350max. 2500
max. 110max. 80
max. +40
Description:Horizontal radially split volute casing pump for dry installation, made ofsuper‐duplex stainless steel.Applications:Booster pump for RO seawater desalination systems.
Data for 50 Hz operation
Also available for 60 Hz
http://shop.ksb.com/catalog/k0/en/product/ES000570
HGM‐RODNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
65 – 250max. 1500
max. 950max. 120max. +40
max. 3600
Description:Horizontal radially split product‐lubricated multistage ring‐section pumpwith radial impellers and plain bearings, axial and radial single‐entry inlet.Duplex and super‐duplex stainless steel variants also suitable for chilledwater applications.Applications:High‐pressure pump for RO seawater desalination systems.
Also available for 60 Hz
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000237
Salino Pressure CenterQ [m3/h]p [bar]T [°C]n [rpm]
max. 23max. 100max. +50
max. 1750
Description:Axial piston pump with integrated energy recovery device in forgedduplex or super‐duplex stainless steel. Product‐lubricated (oil‐free).Applications:Seawater desalination by reverse osmosis (RO) for small and medium‐sizedsystems.Data for 50 Hz and 60 Hz operation
Pumps
Pumps
68
Positive displacement pumps
RC / RCVDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
20 – 100max. 78
max. 100max. 10
+5 to +80max. 1500
Description:Helical gear pump, self‐priming, with bypass valve, close‐coupled design,for horizontal installation with baseplate or vertical installation. Withmechanical seal.Applications:Fuel feed, handling fuel, lubricating oil and viscous fluids, lubricationsystems.
Data for 50 Hz operation
Also suitable for 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000744
Fire‐fighting systems
EDSDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
32 – 300max. 840max. 140
max. 16+5 to +50
max. 3000
Description:Automatic fire‐fighting system consisting of jockey pump and one orseveral duty pumps, with electric motor or diesel engine. Includesmanifold, valves, accessories and control unit. To EN 12845, CEA 4001,UNE‐23500, NFPA‐20, FM, etc.Applications:Office buildings, hotels, industry, shopping malls, etc.
Data for 50 Hz operation
Also suitable for 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000726
DU / EUDNQ [m3/h]H [m]p [bar]T [°C]n [rpm]
32 – 350max. 2500
max. 150max. 25
+5 to +50max. 3000
Description:Automatic fire‐fighting system consisting of pumps with electric motor ordiesel engine and control unit. To EN 12845, CEA 4001, UNE‐23500,NFPA‐20, FM, etc.Applications:Office buildings, hotels, industry, shopping malls, etc.
Data for 50 Hz operation
Also suitable for 60 Hz operation
http://shop.ksb.com/catalog/k0/en/product/ES000727
Not available for worldwide sale Factory‐automated Automation possible
Automation
Automation
69
Control units
Controlmatic ENo. of pumpsVoltage [V]
max. 11~230
Description:Automatic control unit for pressure‐controlled starting, flow‐controlledstopping and monitoring of a single pump.Applications:For water supply systems in combination with Multi Eco, Ixo, UPA 100Cand S 100D.
http://shop.ksb.com/catalog/k0/en/product/ES000276
Controlmatic E.2No. of pumpsVoltage [V]
max. 11~230
Description:Automatic control unit for pressure‐controlled starting, flow‐controlledstopping and monitoring of a single pump.Applications:For water supply systems in combination with Multi Eco, Multichrom S,Ixo, UPA 100C, S 100D.
http://shop.ksb.com/catalog/k0/en/product/ES000276
Cervomatic EDP.2No. of pumpsVoltage [V]
max. 11~230 / 3~400
Description:Automatic control unit for pressure‐controlled starting and eitherpressure‐controlled or flow‐controlled stopping and monitoring of asingle pump.Applications:For water supply systems with pumps of the Multi Eco, Ixo, UPA 100C,S 100D and UPA 150C type series with single‐phase or three‐phase motors.
http://shop.ksb.com/catalog/k0/en/product/ES000275
LevelControl Basic 2No. of pumpsP [kW]Voltage [V]
max. 2max. 22
1~230 / 3~400
Description:Level control unit for controlling and protecting either one or two pumps.DOL starting up to 4 kW, star‐delta starting up to 22 kW. Higher ratingson request.Applications:Tank drainage via float switches, digital switches, 4...20 mA, pneumatic(w/o compressor) or bubbler system in building services and waste waterapplications. Tank filling using float switches, digital switches or 4...20 mAin building services and water supply applications.
Higher ratings and other mains voltages
available on request
http://shop.ksb.com/catalog/k0/en/product/ES000603
UPA ControlNo. of pumpsP [kW]Voltage [V]
max. 13
1~230 / 3~400
Description:The UPA CONTROL unit from KSB is suitable for level control andprotection of submersible borehole pumps, submersible motor pumps anddry‐installed pumps with single‐phase AC motors 1~ 230 V or three‐phasemotors 3~ 230 / 400 V / 50 Hz. The motor is started DOL. Enclosure: IP56,dimensions: 205 × 255 × 170 mm (H × W × D).Applications:Water supply systems in conjunction with UPA 100C, S 100D andUPA 150C.
http://shop.ksb.com/catalog/k0/en/product/ES000006
Automation
Automation
70
hyatronic NNo. of pumpsP [kW]Voltage [V]
max. 622
3~400
Description:Pump control system in control cabinet for cascade starting and stoppingof up to 6 pumps on the mains.Applications:Water supply systems.Higher ratings and other mains voltages
available on request
http://shop.ksb.com/catalog/k0/en/product/ES000303
Monitoring and diagnosis
AmacontrolNo. of pumpsTypeVoltage [V]
max. 1Amacan
230 V AC
Description:Monitoring system for submersible motor pumps, with tripping function.
Control system
BOA‐SystronicNo. of pumpsPNDNVoltage [V]T [°C]
max. 16 / 10 / 16
20 – 20024 V AC
+20 to +120
Description:Energy‐saving system for the coordinated operation of pump and controlvalve. The system provides an all‐in solution designed to access untappedhydraulic savings potential. Irrespective of the pump technology used, itallows savings of 50 % in pump electricity while also reducing primaryenergy costs thanks to lower return flow temperatures. The system can becombined with all control systems and pumps with a 0‐10 V control input.Straightforward integration in automation systems with optional BACnetgateway.Applications:Supply temperature control in HVAC installations with volume flow ratesof 0.5 to 185 m³/h and temperature differentials of 3 to 30 K. Threaded(DN20) or flanged (DN25‐DN200) line connections; suitable for upgradinginstalled systems and for new systems, for connection to all types of heatgenerators (boiler or district heating), all main feed manifolds, all controlsystems, all supply temperatures.
Higher ratings possible upon request.
http://shop.ksb.com/catalog/k0/en/product/ES000494
Not available for worldwide sale
Technology that makes its mark
Your local KSB representative:
The KSB newsletter –
Don‘t miss out, sign up now:
www.ksb.com/newsletter
KSB AktiengesellschaftJohann‐Klein‐Str. 967227 Frankenthal (Germany)www.ksb.com
0506
.02/
22‐E
N /
17/0
2/20
15 /
© K
SB A
ktie
ng
esel
lsch
aft
2015
∙ Su
bje
ct t
o t
ech
nic
al m
od
ific
atio
n w
ith
ou
t p
rio
r n
oti
ce.
Recommended