View
245
Download
6
Category
Preview:
Citation preview
Hardware Specifications M Series Mr Slim City Multi
Systems NetworkCity Multi MNETMr Slim ANETM Series -
Remote controllers NetworkPAR-30MAA ANETPAC-YT51CRB ANETPAR-FA/FL32MA ANETPAR-F27MEA MNETPAC-SE51CRA MNET
MAC-397IF is an ANET converter for M Series
Conversion to MNET M Series Mr Slim (S Series) Mr Slim (P Series) City Multi
Systems InterfacesCity Multi -Mr Slim (P Series) PAC-SF81MAMr Slim (S Series) MAC-399IFM Series MAC-399IF
Interface locationPAC-SF81MA OutdoorMAC-399IF Indoor
M-NETM-NETM-NET M-NET
Inputs / Outputs Interfaces M Series Mr Slim City Multi
InterfacesPAC-SA89TA: Remote On/Off / fire alarm via volt free contact.
PAC-SA88HA: Run/Fault monitoring via 12VDC signal.
TCB1: Remote On/Off / fire alarm via 12VDC signal.
IO Interface: On/Off, fire alarm and run/faultmonitoring using a volt free contact. Setpoint,fan speed and mode using 0 to 10VDC. Two energy saving functions available.
MAC-397IF: Remote On/Off / fire alarm and run OR fault monitoring via volt free contact.
Centralised Controllers M Series Mr Slim (S Series) Mr Slim (P Series) City Multi
The AT50 does not require a PAC-SC51KUAon a single City Multi system.
The GB50ADA does not require a PAC-SC51KUA.
A PAC-SC51KUA is required for the AG150. APAC-SC51KUA is required for the AT50 whenusing splits or more than one City Multi system.
Each centralised controller has the option of:- Fire alarm or On/Off input- Run and fault output- A PAC-YG10HA will be required withAG150 and GB50ADA
- A PAC-YT41HAA will be required with AT50
AT50 GB50ADA AG150 PAC-SC51KUA
MAC-399IF
MAC-397IF
MAC-397IF
PAR-30MAA
PAC-YT51CRB
MAC-399IF PAC-SF81MA
M-NETM-NETM-NET M-NET
MAC-399IF MAC-399IF PAC-SF81MA
MAC-397IF PAC-SA89TA PAC-SA88HA
IO InterfaceTCBI
PAR-30MAA PAR-F27MEA PAC-SE51CRA PAC-YT51CRB
PAR-FL32MA
PAR-FA32MA
PAC-SA89TA PAC-SA88HA TCBI IO InterfaceVMHS andVMA only
IMG001 IMG002 IMG003
IMG004 IMG005 IMG006 IMG007
IMG008 IMG009 IMG010
IMG011
IMG015
IMG012 IMG013 IMG014
PAR-30MAA
Controls Quick Reference Guide 2011
PAC-YT51CRB
PAR-FL32MA
PAR-FA32MA
Third Party Equipment Interfaces
SystemsPAC-YG63MCA is an MNET interface with 2 analogue inputs to connect temperature or humidity sensors.
PAC-YG60MCA is an MNET interface with 4 digital pulse inputs to connect energy meters with pulse outputs.
PAC-YG66DCA is an MNET interface with 2 general equipment input / outputs.
Each interface requires a 24VDC power supply.
The AT50 is only compatible with the PAC-YG66DCA.
GB50ADA
AT50 AG150
BEMS M-NET / A-NET Interfaces
BEMS Modbus BACnet LonWorksHoneywellAndover York SiemensPriva Delta Johnson Realtime Smart CylonSatchwellCrestronInvensysInteractive North BT
BEMS M-NET / A-NET Interfaces
IQ3 Excite XNC supplied by Synapsys Solutions.No commissioning is included with anyBEMS interface.
Panels
The PANEL_RS_SMS is used to automaticallychange over the air conditioning.
The PANEL_RS_SMS can monitor and controlup to 8 single splits using A1Ms. Two A1Msare supplied with the PANEL_RS_SMS.
A fault output is available on thePANEL_RS_SMS for BEMS connection using avolt free contact.
A Pay As You Go SIM card may be installed toreceive SMS under fault conditions.
A Pay As You Go SIM card is required to set upthe panel when using more than 4 single splits.
PAC-YG63MCA PAC-YG66DCA
xxx xxx
xxx xxx
xxx
Modbus BACnet Trend LonWorks KNX-EIB M2M
Modbus
PANEL_RS_SMS
BACnet Trend LonWorks EIB/KNX M2M
GB50ADA
MOD-IP/50 BAC-IP/50 IQ3-XNC
GB50ADA
KNX-IP-EIBMAXI
M2M-IP/50
Compatible with:City M S PCity M S PCity M S PCity M S PCity M S PCity M S PP onlyM S PP onlyM S PM S P
PSU required:24VAC24VAC240VAC240VAC24VAC240VAC240VAC-240VAC-240VAC
MOD-IP/50BAC-IP/50BAC-HD150LMAPKNX-EIB-IPM2M-IP/50A32MA1MBAC-A/50KNX-EIB-A-1M2M-A/16City: City Multi, M: M Series, S: S Series, P: P Series.
A32M BAC-A/50
PAC-SK82SI
PAC-SK82SI
LMAP
IQ3-XNC
PUHZ Only PUHZ Only PUHZ Only PUHZ Only
IMG016
IMG017 IMG018 IMG018A IMG019 IMG020 IMG021 IMG022
IMG023 IMG024 IMG025 IMG026 IMG027 IMG028 IMG029
IMG030
PAC-YG60MCA
PAC-YG10HA PAC-YT41HAAPAC-YG63MCA, PAC-YG60MCA, PAC-YG66DCA
Fire Alarm
AG150
PAC-YG10HA
Fire Alarm
AT50
PAC-YT41HAA
GB50ADABAC-HD150 LMAP
GB50ADA GB50ADA
A1M
PAC-SF81MA
GB50ADA
PAC-SF81MA
KNX-EIB-A-1
MINIM2M-A/16
PANEL_RS_SMS
Controls Quick Reference Guide 2011
x
x
A1M
A1M A1M
General Enquiries 01707 282880
After Sales Service 0161 866 6089
Country of origin: United Kingdom Japan Thailand Malaysia. Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described or to withdraw orreplace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are suppliedsubject to the Companys General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Printed in January 2011 SAP No. 240845
UNITED KINGDOM Mitsubishi Electric Europe Air Conditioning Systems Division, Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England. General enquiries Tel: 01707 282880 Fax: 01707 278881
IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland. Tel: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)
email: air.conditioning@meuk.mee.com web: www.mitsubishielectric.co.uk/aircon
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/CreateJDFFile false /Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles false /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice
Recommended