PARTICULARS
1.1 DATE: JULY 15, 2020
SECTION 00 9111 - ADDENDUM NUMBER 1
1.2 PROJECT: 19048.01 RICHLAND 1 SCHOOL DISTRICT OFFICE HVAC RENOVATION
TO: PROSPECTIVE BIDDERS:
2.1 THIS ADDENDUM FORMS A PART OF THE CONTRACT DOCUMENTS AND MODIFIES THE
ORIGINALPROCUREMENT DOCUMENTS DATED MARCH 5, 2020, WITH AMENDMENTS AND
ADDITIONS NOTED BELOW.
2.2 ACKNOWLEDGE RECEIPT OF THIS ADDENDUM IN THE SPACE PROVIDED IN THE BID
FORM. FAILURE TO DO SO MAY DISQUALIFY THE BIDDER.
2.3 THIS ADDENDUM CONSISTS OF 1 PAGE(S) AND THE FOLLOWING ATTACHMENTS:
A. ACM Report
B. Pre-bid Sign-in Sheet
C. Section 00 1113
2.4 GENERAL
A. RCSD1 will remove and reinstall ceiling devices (i.e. cameras, routers, speakers, etc.) unless noted otherwise in the drawings.
B. All ACM material will be address by RCSD1. See attached report.
C. Attached sign-in sheet from Pre-Bid Meeting.
D. Lay-down area will be provided in the warehouse designated by RCSD.
E. RCSD will provide the contractor with a couple of parking spaces during construction.
F. Coordinate use of bathroom facilities with RCSD.
G. Contractor shall repair walls damaged during construction. Contractor shall note any existing wall damages before any demolition occurs. Contractor is responsible for existing wall damages not noted.
CHANGES TO THE PROJECT MANUAL - INTRODUCTORY REQUIREMENTS, PROCUREMENT
REQUIREMENTS AND CONTRACTING REQUIREMENTS:
3.1 SECTION 00 1113 - INVITATION FOR BIDS FOR CONSTRUCTION SERVICES
A. Replace Section in its entirety.
END OF SECTION
19048.01 / 19048.01 Richland 1 School District Office HVAV Renovation
00 9111 - 1 ADDENDUM NUMBER 1
S&ME, Inc. | 134 Suber Road | Columbia, SC 29210 | p 803.561.9024 | www.smeinc.com
June 17, 2019
Richland County School District One
201 Park Street
Columbia, South Carolina 29201
Attention: Ms. Sylvia Green, Manager of Environmental Safety
sylvia.green@richlandone.org
Reference: Limited Asbestos Sampling
2nd Floor Mechanical Rooms
201 Park Street
Columbia, South Carolina
S&ME Project No. 4261-19-112
Dear Ms. Green:
S&ME, Inc. (S&ME) is pleased to provide this report detailing our limited asbestos sampling of the materials that
may be disturbed by planned renovations to the heating, ventilation and air conditioning (HVAC) equipment on
the second floor of the Richland County School District One (RCSD1) Central Services Facility offices at 201 Park
Street in Columbia, South Carolina. Our services were performed in general accordance with S&ME Proposal No.
42-1900625 dated June 7, 2019 and with the RCSD1 Purchase Order # 20190240 to provide asbestos inspection
services for RCSD1 facilities.
This report is provided for the use of the client. Use of this report by any other parties will be at such party’s sole
risk and S&ME, Inc. disclaims liability for any such us or reliance by third parties. The results presented in this
report are indicative of conditions only during the time of the assessment and of the specific areas referenced and
materials sampled. The information provided in this report should not be used as a bidding document, and field
conditions should be verified by contractors bidding on asbestos removal.
Information concerning this project was provided by you in your June 4, 2019 telephone conversation with Mr.
Tom Behnke of S&ME and during our site visit on June 6, 2019. We understand that renovations are planned for
the HVAC units in the two mechanical rooms on the second floor of the office portion of the building. The
renovations will include removing the existing HVAC units, cutting the existing piping and potentially upgrading
the supply ducts. You requested that S&ME sample the suspect asbestos-containing materials present in the
mechanical rooms that may be disturbed by the planned HVAC renovations as described, and have the samples
analyzed for asbestos content.
Mr. Owen Astwood, P.G. with S&ME mobilized to the site on June 6, 2019 to perform the requested sampling.
S&ME collected bulk samples of the following suspect asbestos-containing materials in both mechanical rooms:
Green cloth wrap over fiberglass pipe insulation;
Yellow cloth wrap over fiberglass pipe insulation;
White cloth wrap over fiberglass duct insulation;
Limited Asbestos Sampling
2nd Floor Mechanical Rooms
Columbia, South Carolina
S&ME Project No. 4261-19-112
June 17, 2019 2
White sealant associated with newer white fiberglass pipe insulation; and
White cloth wrap over fiberglass duct insulation from the supply duct in the welding shop.
The collected bulk samples were recorded on a chain of custody record and submitted to EMSL’s asbestos
laboratory in Pineville, North Carolina to be analyzed by Polarized Light Microscopy (PLM) and Transmission
Electron Microscopy (TEM) methods. The laboratory is accredited by the National Voluntary Laboratory
Accreditation Program (NVLAP), which is administered by the National Institute of Standards and Technology.
The Environmental Protection Agency (EPA) and the South Carolina Department of Health and Environmental
Control (SCDHEC) define materials as asbestos-containing if an asbestos content of greater than one percent
(>1%) is detected in a representative sample.
Asbestos, in concentrations greater than one percent, was not identified as a result of the bulk sampling and analysis.
Select photographs of the observed suspect asbestos-containing materials (ACMs) are attached. A copy of the
laboratory analytical report and chain of custody record are also attached.
Significant destructive sampling was not performed during the limited asbestos sampling. Consequently, if
additional suspect materials are discovered during future renovation or demolition activities, bulk samples must
be collected and analyzed for asbestos content. The EPA and SCDHEC require proper removal and disposal of
ACMs that will be destructively affected by renovation and/or demolition activities.
We appreciate the opportunity to provide you with our industrial hygiene services. If you have any questions
concerning this report, please call us at (803) 561-9024.
Sincerely,
S&ME, Inc.
Owen Astwood, P.G. Tom Behnke, P.G., CHMM
Asbestos Building Inspector Environmental Services Manager
(SCDHEC Lic. No. BI-00475) (SCDHEC Lic. No. MP-00004)
Attachments: Photographs
Laboratory Report and Chain of Custody
Copy of SCDHEC Inspector’s License
Limited Asbestos Sampling
2nd Floor Mechanical Rooms
Columbia, South Carolina
S&ME Project No. 4261-19-112
June 17, 2019 i
Date
: 6/6
/2019
Ph
oto
gra
ph
er:
O. A
stw
oo
d
Location / Orientation Park Street
Remarks Exterior view of the subject building.
Date
: 6/6
/2019
Ph
oto
gra
ph
er:
O. A
stw
oo
d
2 Location / Orientation Southern HVAC room.
Remarks The yellow and green pipe wrap tested negative.
Limited Asbestos Sampling
2nd Floor Mechanical Rooms
Columbia, South Carolina
S&ME Project No. 4261-19-112
June 17, 2019 ii
Date
: 6/6
/2019
Ph
oto
gra
ph
er:
O. A
stw
oo
d
3 Location / Orientation Northern HVAC room.
Remarks The white duct wrap tested negative.
Date
: 6/6
/2019
Ph
oto
gra
ph
er:
O. A
stw
oo
d
4 Location / Orientation Welding shop.
Remarks The white wrap on the supply duct tested negative.
EMSL Analytical, Inc.10801 Southern Loop Blvd Pineville, NC 28134
Tel/Fax: (704) 525-2205 / (704) 525-2382
http://www.EMSL.com / charlottelab@emsl.com
411905565EMSL Order:
Customer ID: S&ME50
Customer PO:
Project ID:
Attention: Phone:Owen Astwood (803) 561-9024
Fax:S&ME, Inc. (803) 561-9177
Received Date:134 Suber Rd. 06/07/2019 9:25 AM
Analysis Date:Columbia, SC 29210 06/11/2019
Collected Date: 06/06/2019
Project: RCSD 1 Mech Rooms
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
PW-1
411905565-0001
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Silver/Green/Beige
Fibrous
Homogeneous
South HVAC Room
PW-2
411905565-0002
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Silver/Green/Beige
Fibrous
Homogeneous
South HVAC Room
PW-3
411905565-0003
None DetectedNon-fibrous (Other)10%Cellulose90%Tan/Green
Fibrous
Homogeneous
South HVAC Room
PW-4
411905565-0004
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Silver/Green/Beige
Fibrous
Homogeneous
North HVAC Room
PW-5
411905565-0005
None DetectedNon-fibrous (Other)90%Cellulose
Glass
5%
5%
Silver/Green/Beige
Fibrous
Homogeneous
North HVAC Room
PW-6
411905565-0006
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Tan/Silver/Green
Fibrous
Homogeneous
North HVAC Room
PW-7
411905565-0007
None DetectedNon-fibrous (Other)10%Cellulose90%Yellow/Beige
Fibrous
Homogeneous
South
PW-8
411905565-0008
None DetectedNon-fibrous (Other)22%Cellulose
Glass
75%
3%
Silver/Yellow/Beige
Fibrous
Homogeneous
South
PW-9
411905565-0009
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Tan/Silver/Yellow
Fibrous
Homogeneous
South
PW-10
411905565-0010
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Silver/Yellow/Beige
Fibrous
Homogeneous
North
PW-11
411905565-0011
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Silver/Yellow/Beige
Fibrous
Homogeneous
North
PW-12
411905565-0012
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Tan/Silver/Yellow
Fibrous
Homogeneous
North
DW-1
411905565-0013
None DetectedNon-fibrous (Other)15%Cellulose85%White/Silver
Fibrous
Homogeneous
South
DW-2
411905565-0014
None DetectedNon-fibrous (Other)15%Cellulose85%White/Silver
Fibrous
Homogeneous
South
DW-3
411905565-0015
None DetectedNon-fibrous (Other)10%Cellulose
Glass
85%
5%
Tan/White/Silver
Fibrous
Homogeneous
South
DW-4
411905565-0016
None DetectedNon-fibrous (Other)15%Cellulose85%White
Fibrous
Homogeneous
North
Initial report from: 06/11/2019 15:17:00
Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 6/11/2019 3:17 PM
EMSL Analytical, Inc.10801 Southern Loop Blvd Pineville, NC 28134
Tel/Fax: (704) 525-2205 / (704) 525-2382
http://www.EMSL.com / charlottelab@emsl.com
411905565EMSL Order:
Customer ID: S&ME50
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
DW-5
411905565-0017
None DetectedNon-fibrous (Other)15%Cellulose85%Silver
Fibrous
Homogeneous
North
DW-6
411905565-0018
None DetectedNon-fibrous (Other)10%Cellulose
Glass
85%
5%
Tan/White/Silver
Fibrous
Homogeneous
North
DW-7
411905565-0019
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Tan/White/Silver
Fibrous
Homogeneous
Supply duct in
Welding Shop
DW-8
411905565-0020
None DetectedNon-fibrous (Other)20%Cellulose
Glass
75%
5%
Tan/Black/Silver
Fibrous
Homogeneous
Supply duct in
Welding Shop
DW-9
411905565-0021
None DetectedNon-fibrous (Other)10%Cellulose
Glass
85%
5%
Tan/White/Silver
Fibrous
Homogeneous
Supply duct in
Welding Shop
DS-1
411905565-0022
None DetectedCa Carbonate
Non-fibrous (Other)
5%
93%
Wollastonite2%Beige
Non-Fibrous
Homogeneous
South (New t/g TSI)
DS-2
411905565-0023
None DetectedCa Carbonate
Non-fibrous (Other)
5%
95%
White
Non-Fibrous
Homogeneous
South (New t/g TSI)
DS-4
411905565-0024
None DetectedCa Carbonate
Non-fibrous (Other)
5%
93%
Wollastonite2%Beige
Non-Fibrous
Homogeneous
North (New t/g TSI)
DS-5
411905565-0025
None DetectedCa Carbonate
Non-fibrous (Other)
5%
94%
Wollastonite1%White
Non-Fibrous
Homogeneous
North (New t/g TSI)
Analyst(s)
Kristie Elliott (16)
Katherine Sluder (9)
Lee Plumley, Laboratory Manager
or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim
Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without
written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All
samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of
the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Pineville, NC NVLAP Lab Code 200841-0, VA 3333 00312
Initial report from: 06/11/2019 15:17:00
Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 6/11/2019 3:17 PM
EMSL Analytical, Inc.10801 Southern Loop Blvd Pineville, NC 28134
Tel/Fax: (704) 525-2205 / (704) 525-2382
http://www.EMSL.com / charlottelab@emsl.com
EMSL Order: 411905565
Customer ID: S&ME50
Customer PO:
Project ID:
Attention: Owen Astwood Phone: (803) 561-9024
S&ME, Inc. Fax: (803) 561-9177
134 Suber Rd. Received Date: 06/07/2019 9:25 AM
Columbia, SC 29210 Analysis Date: 06/12/2019
Collected Date: 06/06/2019
RCSD 1 Mech RoomsProject:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via
EPA/600/R-93/116 Section 2.5.5.1
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
DS-3
411905565-0026
South (New t/g TSI) White
Non-Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
DS-6
411905565-0027
North (New t/g TSI) White
Non-Fibrous
Heterogeneous
100.0 None No Asbestos DetectedOther
Analyst(s)
Derrick Young (2) Lee Plumley, Laboratory Manager
or other approved signatory
This laboratory is not responsible for % asbestos in total sample when the residue only is submitted for analysis. The above report relates only to the items tested. This report may not be reproduced,
except in full, without written approval by EMSL Analytical , Inc. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with
multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Pineville, NC
Initial report from: 06/12/2019 15:31:30
ASB_PLMEPANOB_0012_0002 Printed 6/12/2019 3:31:37PM Page 1 of 1
S&ME, Inc. | 134 Suber Road | Columbia, SC 29210 | p 803.561.9024 | www.smeinc.com
South Carolina Department
of
Health and Environmental Control
Asbestos License
Owen R. Astwood
SECTION 00 1113
Richland County School District One
INVITATION FOR BIDS
FOR CONSTRUCTION SERVICE
Solicitation #
Date Issued
Procurement Officer
Phone
E-mail Address
2021-003
6/25/20
Harrison Joseph
803.231.7052
Harrison.Joseph@richlandone.org
Sealed bids for RCSD1 Central Service Building HVAC Renovations, will be received from qualified
bidders that are, properly licensed under the laws of the State of South Carolina. These bids will be
opened and read aloud by the Owner at the office of the Director of Facility Services, Central Services
Facility, 201 Park Street, Room 209 Columbia, SC 29201. Bids received after the indicated times will
be rejected and returned to the Bidder unopened. All questions must be submitted via email to:
Harrison Joseph Construction Contracts Manager (E-mail Above)
SCHEDULE OF EVENTS DATE AND TIME
Site Visits held on: July 8, 2020 at 2:00 pm (EST)
Pre-Bid conference will be held on:
(Location of Pre-proposal Meeting: Procurement Services 201 Park St.
Rm. 204 Columbia, S.C. 29201). All bidders are strongly urged to attend
July 8, 2020 at 2:00 pm (EST)
Bid Questions must be received by: July 15, 2020 at 2:00 pm (EST)
Bid Questions must be received by July 22, 2020 at 2:00 pm (EST)
Bid(s) must be received by: July 30, 2020 at 2:00 pm (EST)
Bids will be opened on: July 30, 2020 at 2:00 pm (EST)
PROJECT INFORMATION
The name of the project is RCSD1 Central Service Building HVAC Renovations
Project Address: 2219 Barhamville Rd, Columbia, SC 29204
The Owner is: Richland County School District One 201 Park Street Columbia, SC 29201
The Architect/Engineer is: GMK Associates
The Construction Manager is: n/a
Description of the Project The scope of work includes replacement of existing HVAC System serving a portion of the 1st floor and all of the second floor in the Central Servies Building. Chilled water VAV air handlers, VAV boxes with hot water reheat, supply and return ductwork. Related work includes minor wall repairs,
minor removal and replacement of ceilingllights and electrical work related to the HVAC system replacements.
Project will be bid as a Competitive Sealed Bid
Bid Documents
Bidding Documents are available for inspection at the following locations:
GMK Associates, 1201 Main Street, Suite 2100, Columbia, SC 29201; by appointment only. Bidding Documents may be obtained from the Architect via share file. Bids will be binding for a period of 60 (sixty) calendar days from the date bids are opened. Contact Jody Ricard at jricard@gmka.com.
Bonds and Insurance
All bids are to be accompanied by a bid bond or certified check of not less than five percent (5%) of the base bid. Bid securities of the three lowest bidders will be retained until Contract award and execution.
The successful bidder will be required to furnish Performance Bond, and Labor and Materials Bond in the amount of one hundred percent (100%) of the Contract Amount. The successful bidder will also be required to furnish builder's risk insurance for the project.
Bids are to be submitted on the bid form enclosed in the project manual, and shall be enclosed in a sealed opaque envelope bearing the name and address of the bidder, contractor's license number and bidder's license number (if applicable), the name of project and the solicitation number. All bids must comply with the laws of the State of South Carolina.
THE OWNER RESERVES THE RIGHT TO REJECT ANY AND ALL BIDS, WAIVE INFORMALITIES AND AWARD THE CONTRACT IN THE BEST INTEREST OF THE OWNER.
END OF SECTION 00 1113