ServiceService
Inovia Cond MAXInovia Cond MAX
CIRCUITO GASCIRCUITO GAS
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceSCHEMA CIRCUITO GAS SCHEMA CIRCUITO GAS
DIAFRAMMA
VALVOLA GAS
VENTILATORE
SCAMBIATORE
BRUCIATORE
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceVALVOLA GAS PREMIXVALVOLA GAS PREMIX
MODELLOMODELLO::•SIT 848 SIGMASIT 848 SIGMA•POSSIBILITA’ DI TARATURA DELLA MASSIMA QUANTITA’ POSSIBILITA’ DI TARATURA DELLA MASSIMA QUANTITA’ DI GAS GRAZIE A INSERIMENTO VITE DI REGOLAZIONE DI GAS GRAZIE A INSERIMENTO VITE DI REGOLAZIONE MASSIMO GAS;MASSIMO GAS;•PRESA DI COMPENSAZIONE;PRESA DI COMPENSAZIONE;CARATTERISTICHECARATTERISTICHE::•AGENDO IN SENSO ORAIO SULLA VITE SI PUO’ VARIARE AGENDO IN SENSO ORAIO SULLA VITE SI PUO’ VARIARE IL VALORE COIL VALORE CO2 2 ALLA MASSIMA POTENZAALLA MASSIMA POTENZA
REG. MAXREG. MAX
REG. MAXREG. MAX
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceDIAFRAMMA GAS DIAFRAMMA GAS
• COMPITOCOMPITO– RIDURRE LA MASSIMA PORTATA DI GAS AL RIDURRE LA MASSIMA PORTATA DI GAS AL
BRUCIATOREBRUCIATORE
• CARATTERISTICHE CARATTERISTICHE – ANELLO IN OTTONE CON FORI CALIBRATI IN ANELLO IN OTTONE CON FORI CALIBRATI IN
BASE AL TIPO DI GAS E POTENZA CALDAIABASE AL TIPO DI GAS E POTENZA CALDAIA
METANO METANO GPLGPL
25 S25 S 450450 345345
35 S35 S 540540 420420
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceMIXER ARIA -AERTECHMIXER ARIA -AERTECH
COMPITOCOMPITO•MISCELARE L’ARIA CON IL GAS NELLE GIUSTE MISCELARE L’ARIA CON IL GAS NELLE GIUSTE PROPORZIONIPROPORZIONI•RIDURRE RUMOROSITA’ BRUCIATORERIDURRE RUMOROSITA’ BRUCIATORECARATTERISTICHECARATTERISTICHE•SVILUPPATO PER BRUCIATORE G20 E G30/31SVILUPPATO PER BRUCIATORE G20 E G30/31
VANTAGGI NUOVO AERTECHVANTAGGI NUOVO AERTECH•MIGLIORATA LA FACILITA’ DI MANUTENZIONE (tenuta MIGLIORATA LA FACILITA’ DI MANUTENZIONE (tenuta tubo-aertech con or + forcina acciaio);tubo-aertech con or + forcina acciaio);•MIGLIORATA SILENZIOSITA’ CALDAIAMIGLIORATA SILENZIOSITA’ CALDAIA
RESTRICTOR DI MISCELAZIONE RESTRICTOR DI MISCELAZIONE ARIA-GAS:ARIA-GAS:24 KW: COLORE FUCSIA 24 KW: COLORE FUCSIA 32 KW: COLORE BLU32 KW: COLORE BLU
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceVENTILATORE VENTILATORE
• COMPITO– INVIARE AL BRUCIATORE LA MISCELA INVIARE AL BRUCIATORE LA MISCELA
ARIA/GAS ARIA/GAS – EVACUARE I PRODOTTI DELLA EVACUARE I PRODOTTI DELLA
COMBUSTIONECOMBUSTIONE– MODULARE LA POTENZA DEL MODULARE LA POTENZA DEL
BRUCIATORE VARIANDO IL N° DI BRUCIATORE VARIANDO IL N° DI GIRI. GIRI.
• CARATTERISTICHE – MODELLO: EBM MRG118 – ALIMENTAZIONE ELETTRCA:
230V ca – POTENZA 60 W – COLLEGATO CON 2 CABLAGGI UNO
DI POTENZA E UNO DI SEGNALE
ALIMENTAZIONE 230 VALIMENTAZIONE 230 V SEGNALE CONTROLLO SEGNALE CONTROLLO NUMERO DI GIRINUMERO DI GIRI
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceBRUCIATOREBRUCIATORE
• COMPITO – PROGETTATO PER OTTIMIZZARE LA PROGETTATO PER OTTIMIZZARE LA
COMBUSTIONE A PREMISCELAZIONE COMBUSTIONE A PREMISCELAZIONE CHE VIENE EFFETTUATA DAL SISTEMA CHE VIENE EFFETTUATA DAL SISTEMA VENTILATORE-VALVOLA GASVENTILATORE-VALVOLA GAS
• CARATTERISTICHE– BRUCIATORE ECOLOGICO IN ACCIAIO BRUCIATORE ECOLOGICO IN ACCIAIO
INOX AISI INOX AISI – RIDOTTE EMISSIONI INQUINANTI DI RIDOTTE EMISSIONI INQUINANTI DI
Nox (CALDAIA CLASSE 5 NOX)Nox (CALDAIA CLASSE 5 NOX)– FACILMENTE ESTRAIBILE DAL FACILMENTE ESTRAIBILE DAL
FRONTALEFRONTALE– DUE ELETTRODI MONTATI: UNO DI DUE ELETTRODI MONTATI: UNO DI
SCARICA E UNO DI IONIZZAZIONESCARICA E UNO DI IONIZZAZIONE– PREGETTATO PER G20 G30 G31PREGETTATO PER G20 G30 G31
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceSICUREZZE TERMICHE SICUREZZE TERMICHE
• COMPITO – EVITA SOVRATEMPERATURE IN CALDAIA O SU LATO FUMIEVITA SOVRATEMPERATURE IN CALDAIA O SU LATO FUMI
• CARATTERISTICHE– TERMOSATATO MASSIMA TEMPERATURATERMOSATATO MASSIMA TEMPERATURA
– TEMPERATURA DI INTERVENTO 103 °C, RIARMO TEMPERATURA DI INTERVENTO 103 °C, RIARMO AUTOMATICOAUTOMATICO
– IN CASO DI INTERVENTO IL DISPLAY VISUALIZZA IN CASO DI INTERVENTO IL DISPLAY VISUALIZZA E02E02– SONDA FUMI F1SONDA FUMI F1 : :
– PRESERVA I CONDOTTI DI ESPULSIONEPRESERVA I CONDOTTI DI ESPULSIONE– CON LA TEMPERATURA FUMI TRA I 110° C E I 120°C CON LA TEMPERATURA FUMI TRA I 110° C E I 120°C
VIENE FORZATA LA MODULAZIONEVIENE FORZATA LA MODULAZIONE– OLTRE I 120°C BLOCCO FIAMMA E DIAGNOSTICA LED OLTRE I 120°C BLOCCO FIAMMA E DIAGNOSTICA LED
SEGNALANO LIMITAZIONE TEMPERATURA SONDA SEGNALANO LIMITAZIONE TEMPERATURA SONDA SCARICO FUMI (SCARICO FUMI (E10E10))
– TERMOFUSIBILE F2:TERMOFUSIBILE F2:– L’INTERVENTO DI F2 INDICA UNO SCARSO SCAMBIO L’INTERVENTO DI F2 INDICA UNO SCARSO SCAMBIO
TERMICOTERMICO– SE LA TEMPERATURA FUMI, PRIMA DI PASSARE PER LO SE LA TEMPERATURA FUMI, PRIMA DI PASSARE PER LO
SCAMBIATORE CONDENSANTE, SUPERA I 140° BLOCCA SCAMBIATORE CONDENSANTE, SUPERA I 140° BLOCCA IMMEDIATAMENTE IL BRUCIATORE INTERROMPENDO LA IMMEDIATAMENTE IL BRUCIATORE INTERROMPENDO LA SONDA FUMI (SONDA FUMI (E09)E09)
SONDA FUMI F1F1
TERMOFUSIBILETERMOFUSIBILE F2F2
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceSIFONE SCARICO CONDENSASIFONE SCARICO CONDENSA
• COMPITOCOMPITO– CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO CONSENTE LO SCARICO DELLA CONDENSA ALL’ESTERNO
DEL GRUPPO CONDENSANTEDEL GRUPPO CONDENSANTE– EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO EVITA CHE I FUMI POSSANO USCIRE DALLO SCARICO
CONDENSA CONDENSA • CARATTERISTICHECARATTERISTICHE
– DIAMETRO RACCORDO COLLEGAMENTO: 25 mm.DIAMETRO RACCORDO COLLEGAMENTO: 25 mm.– TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE TUBO DI COLLEGAMENTO: FLESSIBILE IN MATERIALE
PLASTICO L= 45 cmPLASTICO L= 45 cm– PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL PALLINA INTERNA PER EVITARE FUORIUSCITE DI FUMI NEL
CASO IL SIFONE SI ASCIUGHICASO IL SIFONE SI ASCIUGHI
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceService
ATTIVAZIONE SPAZZACAMINOATTIVAZIONE SPAZZACAMINO• ENTRARE IN MODALITA’ SPAZZACAMINO ENTRARE IN MODALITA’ SPAZZACAMINO
SEGUENDO LE IDICAZIONI SOTTO SEGUENDO LE IDICAZIONI SOTTO RIPORTATE:RIPORTATE:– CHIUDERE IL CONTATTO TACHIUDERE IL CONTATTO TA– TENERE PREMUTO I PULSANTI A+B+D IN TENERE PREMUTO I PULSANTI A+B+D IN
FIGURA (CIRCA 10 sec): IL DISPLAY FIGURA (CIRCA 10 sec): IL DISPLAY INDICHERA’ INDICHERA’ P01P01 CON IL RELATIVO CON IL RELATIVO VALORE IMPOSTATOVALORE IMPOSTATO
– PREMERE CONTEMPORANEAMENTE I PREMERE CONTEMPORANEAMENTE I TASTI A e B ; IL DISPLAY INDICHERA’ TASTI A e B ; IL DISPLAY INDICHERA’ LPLP + SIMBOLO SPAZZACAMINO + SIMBOLO SPAZZACAMINO (FUNZIONE SPAZZACAMINO ATTIVA) (FUNZIONE SPAZZACAMINO ATTIVA)
TARATURA VALVOLA GASTARATURA VALVOLA GAS
COME PER TUTTE LE CALDAIE A COME PER TUTTE LE CALDAIE A CONDENSAZIONE PREMISCELATE CONDENSAZIONE PREMISCELATE LE TARATURE DEL GAS SI LE TARATURE DEL GAS SI ESEGUONO SOLO CON ESEGUONO SOLO CON L’UTILIZZO DELL’ANALIZZATORE L’UTILIZZO DELL’ANALIZZATORE DI COMBUSTIONE E SEGUENDO DI COMBUSTIONE E SEGUENDO LA PROCEDURA SOTTO LA PROCEDURA SOTTO INDICATA.INDICATA.
A+A+BB
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceService
REGOLAZIONE MINIMO GASREGOLAZIONE MINIMO GAS1.1. ENTRARE IN MODALITA’ SPAZZACAMINO (VEDI ENTRARE IN MODALITA’ SPAZZACAMINO (VEDI
PAGINA PRECEDENTE)PAGINA PRECEDENTE)2.2. PRELEVARE ABBONDANTE ACQUA SANITARIA (IL PRELEVARE ABBONDANTE ACQUA SANITARIA (IL
DISPLAY DA’ LA INDICAZIONE DISPLAY DA’ LA INDICAZIONE LPLP OVVERO OVVERO ATTIVAZIONE DELLA FUNZIONE SPAZZACAMINO ATTIVAZIONE DELLA FUNZIONE SPAZZACAMINO MINIMA POTENZA, ALTERNATA AL VALORE DELLA MINIMA POTENZA, ALTERNATA AL VALORE DELLA TEMPERATUTRA DI MANDATA)TEMPERATUTRA DI MANDATA)
3.3. AVVIARE ANALIZZATORE DI COMBUSTIONE AVVIARE ANALIZZATORE DI COMBUSTIONE 4.4. CONFRONTARE IL VALORE DI CO2 LETTO CON CONFRONTARE IL VALORE DI CO2 LETTO CON
QUELLO RIPORTATO NEL LIBRETTO A CORREDO QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (8,7% - 9,3%)DELLA CALDAIA (8,7% - 9,3%)
5.5. AGIRE SULLA VITE INICATA IN FIGURA PER AGIRE SULLA VITE INICATA IN FIGURA PER MODIFICARE IL VALORE DI CO2 ALLA MINIMA MODIFICARE IL VALORE DI CO2 ALLA MINIMA POTENZA POTENZA (AVVITANDO CO2 AUMENTA)(AVVITANDO CO2 AUMENTA)
NBNBLA VITE DEL MINIMO E’ MOLTO SENSIBILE. AGIRE AL MASSIMO LA VITE DEL MINIMO E’ MOLTO SENSIBILE. AGIRE AL MASSIMO
DI ¼ DI GIRO PER VOLTA ED ATTENDERE CHE IL VALORE DI DI ¼ DI GIRO PER VOLTA ED ATTENDERE CHE IL VALORE DI CO2 LETTO SULLO STRUMENTO RIMANGA COSTANTECO2 LETTO SULLO STRUMENTO RIMANGA COSTANTE
REG. MINIMO REG. MINIMO GASGAS
TARATURA VALVOLA GASTARATURA VALVOLA GAS
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceService
REGOLAZIONE MASSIMO GASREGOLAZIONE MASSIMO GAS1.1. PREMERE DIVERSE VOLTE I TASTI PREMERE DIVERSE VOLTE I TASTI AA OO BB FINO A FINO A
CHE IL DISPLAY NON INDICA CHE IL DISPLAY NON INDICA DPDP ALTERNATO AL ALTERNATO AL VALORE DELLA TEMPERATURA DI MANDATA VALORE DELLA TEMPERATURA DI MANDATA (FUNZIONE FORZATURA MASSIMA POTENZA (FUNZIONE FORZATURA MASSIMA POTENZA ATTIVATA)ATTIVATA)
2.2. CONFRONTARE IL VALORE DI CO2 LETTO CON CONFRONTARE IL VALORE DI CO2 LETTO CON QUELLO RIPORTATO NEL LIBRETTO A CORREDO QUELLO RIPORTATO NEL LIBRETTO A CORREDO DELLA CALDAIA (ES. METANO 9,3% – 9,9%)DELLA CALDAIA (ES. METANO 9,3% – 9,9%)
3.3. AGIRE SULLA VITE INDICATA IN FIGURA PER AGIRE SULLA VITE INDICATA IN FIGURA PER MODIFCARE IL VALORE DI CO2 ALLA MASSIMA MODIFCARE IL VALORE DI CO2 ALLA MASSIMA POTENZA POTENZA (AVVITANDO CO2 DIMINUISCE)(AVVITANDO CO2 DIMINUISCE)
REGOLAZIONE REGOLAZIONE MASSIMO GASMASSIMO GAS
TARATURA VALVOLA GASTARATURA VALVOLA GAS
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceTRASFORMAZIONE GASTRASFORMAZIONE GAS
TOGLIERE LA FORCINA “A”SVITARE IL GIRELLO “C”TOGLIERE IL TUBO “B”
ESEGUIRE LA TRASFORMAZIONE DEL TIPO DI GASSOSTITUENDO CORRETTAMENTE IL DIAFRAMMA
GAS
METANO METANO GPLGPL
25 S25 S 450450 345345
35 S35 S 540540 420420
RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO RinNOVA COND X, Inovia Cond , Inovia IN: CIRCUITO GASGAS
ServiceServiceTRASFORMAZIONE GASTRASFORMAZIONE GAS
ENTRARE IN MODALITA’ PROGRAMMAZIONE
SCORRERE I PARAMETRI FINO A FARE APPARIRE SUL DISPLAY LCD LE LETTERE P05
MODIFICARE IL VALORE DEL PARAMETRO “5” A SECONDA DEL TIPO DI GAS
CONFERMARE LA MODIFICA PREMENDO IL TASTO
EFFETTUARE LE TARATURE DELLA VALVOLA GAS