View
45
Download
6
Category
Preview:
Citation preview
Unrestricted © Siemens AG 2018
siemens.com/softstarter3RW5Unrestricted © Siemens AG 2018
SIRIUS 3RW5 Soft StartersAs versatile as your application
Unrestricted © Siemens AG 2018
SIRIUS 3RW Soft Starters matches the versatility of yourindividual challenges in fixed speed applications
Pumping Ventilating Compressing Conveying Processing
• Water & waste watersewage
• Cooling pump
• Hydraulic press
• Air conditioning
• Cooling Compressor
• Tunnel ventilation
• Air compressor
• Cooling compressor
• Compressor in biogasplant
• Conveyor belt in cementfactory
• Conveyor belt in quarry
• Reamer in biogas plant
• Stone crusher in quarry
• Agitator in chocloatefactory
• Centrifuge in card boardrecycling plant
Page 2
Unrestricted © Siemens AG 2018
SIRIUS 3RW Soft Starters until today
Page 3
Power [kW] at 400 V
High-Feature
56055 250 1000 1200
3RW30
3RW40
3RW44
5,51,5 15
Standard
2-phase controlled
3-phase controlled
S0-S3S6-S12
Functionality
S00-S3
Unrestricted © Siemens AG 2018
The new SIRIUS 3RW5 Soft StartersAs versatile as your application
3RW553RW52
Page 4
Unrestricted © Siemens AG 2018
3RW525,5 … 315/560 kW
(√3)
3RW555,5 … 710/1.200* kW
(√3)
3RW301,5 … 55 kW
3RW405,5 … 55 kW
3RW4055 … 250 kW
3-ph
ase
cont
rolle
d
TIA
inte
grat
ion
2-ph
ase
cont
rolle
d
High
General
Basic
Prod
ucts
Page 5
SIRIUS 3RW Soft Starters – As versatile as your applicationNew portfolio at a glance
*) in Step 2 with Size 5, 315/560 kW in Step 1)
Current limitation
Torque Control
Soft Torque
Analog-Output0..10 V or 4..20 mA
Electronic and ThermalMotor overloadprotection
HMI and Communicationmodules
Condition Monitoring
Autoparameterization
Voltage ramp
Unrestricted © Siemens AG 2018
SIRIUS 3RW30/40 Soft StartersBasic performance
Top highlights Feature / Function Benefit
Voltage ramp and current limitationfunction u Protection of electric and mechanic
Hybrid-technology (integratedbypass contactor) u
Less heat dissipation andtemperature rise in the controlcabinet, energy saving
Parameter assignment by only twoparameters u Fast and easy commisioning
Compact design u Space and cost saving
Tested load feeder combinationspossible with components from theSIRIUS modular system
uEasy selection and design ofelectric components for motorcontrol
Page 6
Unrestricted © Siemens AG 2018
SIRIUS 3RW52 Soft StartersGeneral performance
Top highlights Feature / Function Benefit
Hybrid technology and 3-phasemotor control u
Minimal heat dissipation andsymmetric/optimal motor control
TIA-Integration – communicationmodule, operator panel optional u
Efficient engineering and highestflexibility in many automation fields
Soft Torque uReduced mechanical stress andoptimal pump stopping
Parameterization via rotaryknobs/potentiometers u Fast and easy commissioning
Wide range control and mainvoltage u
Less variants, high availability inweak power grids
Page 7
Unrestricted © Siemens AG 2018
SIRIUS 3RW55 Soft StartersHigh performance
Top highlights Feature / Function Benefit
Autoparameterization uEasy and adaptive commissioningeven in changing load profiles
Hybrid technology and 3-phasemotor control u
Minimal heat dissipation andsymmetric/optimal motor control
TIA-Integration – communicationmodule optional, operator panelstandard
uEfficient engineering and highestflexibility in many automation fields
Operator panel with coloreddisplay, local ethernet, micro-SD u
High flexibility in user-interface andintuitive menu structure
Torque Control, Pump stopping &cleaning function u
Reduced mechanical stress andoptimal pump stopping
Page 8
Restricted © Siemens AG 2017Page 9
SIRIUS 3RW55 Soft StartersAutoparameterization
The cluelesscommissioningengineer
Use-Cases
Changing load
A
B
What needsto be done?
Autoparameterization in 3RW55
Set rated motor current IeSet points:
• Type of load / application
Autoparameterization: Soft and smooth motor start guaranteed –perfect for constant and slightly changing load characteristics
How does itwork?
Ramp-up time as control value
Continuous optimization of parameters with everysingle start (initially with default-parameter set)
What needsto be kept inmind?
Underdimensioning (Soft Starter and/or motor)and/or too high switching frequency causestripping of motor overload or device self proteciton
Previously: Commissioningdifficult and time consuming
Unrestricted © Siemens AG 2018
SIRIUS 3RW59 AccessoriesC
omm
unic
atio
nH
MI
PROFINET-Std, EtherNet/IP,Modbus-TCP PROFIBUS Modbus-RTU
HMI High-Feature HMI Standard
52 55ü
PROFINET-HF(switched Ethernet)
52 55ü ü
52 55ü ü
52 55ü ü
52 55ü
52 55ü ü
Page 10
Unrestricted © Siemens AG 2018Page 11
SIRIUS 3RW Soft Starters
3RW52
Depth< 205 mm
Size 1Size 2/3Size 4
Size 1
3RW55
Size 4 Size 2/3
Unrestricted © Siemens AG 2018
Product data overview
3RW44 3RW52 (S1 - S4) 3RW55 (S1 - S4)Rated current 29-1280 A 11-570 A 11-570 A
Main voltage200-480 V400-600 V400-690 V
200-480 V200-600 V
200-480 V200-690 V
Bypass system Integrated (hybrid-technology)Number of controlled phases 3Connection type Standard, Inside Delta
Control voltage 115 V AC230 V AC
24 V AC/DC110 - 250 V AC
Electronic motor overload protection CLASS 5, 10, 15, 20, 30 CLASS 10A, 10E, 20E CLASS 10A, 10E, 20E, 30E
Thermal motor overload protection PTC, Klixon, Thermoclick PTC Typ A, Thermoclick (optional) PTC Typ A, Thermoclick
Analog Output --- 0-10 V, 4-20 mA (optional) 0-10 V, 4-20 mA
Protocol PB, PN-HF PN-Std, PB, MB-TCP, PN-HF, ETH-IP, MB-RTU
Communication optional
Operator panel/displayHMI Standard- and High-Feature-HMI High-Feature-HMI
optional for cabinet door detachable/optional for cabinet doorPCB coating all PCBs
Page 12
Unrestricted © Siemens AG 2018
Questions, might be interesting for you and your customer
Impo
rtanc
efo
rdec
isio
nm
akin
g
1. Does the application need speed
control once the motor is at speed?
2. Does the application need full
torque at zero speed?
3. Does the application need precise
starting and stopping times?
Critical Questions
?If Yes on 1questionGo with SINAMICS
If No on allquestionsGo withSIRIUS Soft Starters
Unrestricted © Siemens AG 2018
Industrial Controls is the best solution in fixed speed applications
Power loss Heat Space
Hyb
rid s
tart
ing
Elec
tron
ic s
tart
ing
€H
ybrid
sta
rtin
g
Elec
tron
ic s
tart
ing
Hyb
rid s
tart
ing
Elec
tron
ic s
tart
ing
Unrestricted © Siemens AG 2018
Space, space, space – Soft Starters are the most compactsolution for motor starting in fixed speed applications
15 kW
3RW5 Size 1 V20 G120 3RW5 Size 3 G120
90 kW
Unrestricted © Siemens AG 2018
The SIRIUS 3RW5 Soft Starters sets new standards inDigitalization in the Motor Starters market
TIA Integration• Communication
PROFINET, PROFIBUS, ...• Simple and efficient Engineering
+
Application specificfunctions• Auto parameterization• Preventive Maintenance
+Efficiently Combined• Tested combinations
(SIRIUS Modular System)• Certificates for worldwide use
+
Digitalization• Condition Monitoring• SIMATIC Energy Suite• Digital Twin
(Efficient Engineering)• Simulation Tool
+Full Portfolio• From 5.5 kW up to 1200 kW• 3 product lines: Basic, General
and High Performance
+availableHMI 2018
Page 17
Unrestricted © Siemens AG 2018
Wim JanssensSales SpecialistRC-BE DF CP / SIRIUS Soft Starter 3RW
Guido Gezellestraat 1231654 Beersel
Mobile: +32 499 69 35 61
E-mail: wim.janssens@siemens.com
Thank you for your attention
Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features whichmay not always specifically reflect those described, or which may undergo modification in the course of further development of the products. Therequested performance features are binding only when they are expressly agreed upon in the concluded contract.
All product designations, product names, etc. may contain trademarks or other rights of Siemens AG, its affiliated companies or third parties.Their unauthorized use may infringe the rights of the respective owner.
siemens.com
Page 18