I N STR UCTION MAN UAL

OR IG I NAL I N STR UCTION S /TRAN S LATION OF OR IG I NAL I N STR UCTION S

R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S

PROD UCT

SP Impeller Identification Guide

J P-507 R03 (03/2016)

2

3

Impeller Identification GuideTake good care of the cooling system Change to a new impeller every yearThe impeller is a very important security device. Its task is to pump the water through the cooling system of the engine. But remember that the impeller should be replaced every year, at spring launch.

This is how to remove the old impellerRemove the impeller with a slip joint plier or a Johnson Impuller.

This is how to fit the new oneLubricate the shaft and the inside of the pump body and the end cover. Use soap or vaseline (petroleum jelly) to help develop prime and prevent damage from dry-running the pump at initial start-up. Mount the impeller by making a pushing and twisting movement in the rotating direction. Lubricated impel-lers should not be stored for extended periods of time. Engine should be run after installation of a new impeller to wash out the lubrication.These recommendations also apply to any service work on the pump and its com-ponents that require the use of lubrica-tion inside the pump for assembly and start-up.

Order No. 09-950-9300 – Johnson Pump Impuller

4

65 mmØ

50,2 mm}65 mmØ

50,2 mm}JP Impeller 09-SP70

replaces Kashijama impeller

SP70/SPM70

JP Impeller 09-SP100

replaces Kashijama impeller SP100/KP100

5

Ø 80 mm

54,1 mm}

Ø 80 mm

54,1 mm}JP Impeller 09-SP100

replaces Kashijama impeller

SP100/KP100

6

Ø 93 mm

43 mm}

Ø 93 mm

43 mm}JP Impeller 09-SP150

replaces Kashijama impeller

SP150/KP150

JP Impeller 09-SP200

replaces Kashijama impeller SP200/KP200/SPM200

7

Ø 93 mm

63 mm}

Ø 93 mm

63 mm}JP Impeller 09-SP200

replaces Kashijama impeller

SP200/KP200/SPM200

8

Ø 94,5 mm

63,4 mm}

Ø 94,5 mm

63,4 mm}JP Impeller 09-SP220

replaces Kashijama impeller

SP210/SP220

JP Impeller 09-SP280

replaces Kashijama impeller SP280

9

Ø 95 mm

88,7 mm}Ø 95 mm

88,7 mm}JP Impeller 09-SP280

replaces Kashijama impeller SP280

10

Ø 93 mm

95,5 mm}Ø 93 mm

95,5 mm}JP Impeller 09-SP300

replaces Kashijama impeller SP300

JP Impeller 09-SP500

replaces Kashijama impeller SP500

11

Ø 127,78 mm

101,6 mm}

Ø 127,78 mm

101,6 mm}JP Impeller 09-SP500

replaces Kashijama impeller SP500

S PX FLOW TECH NOLOGY SWE D E N AB

Nastagatan 19, P.O. Box 1436

SE-701 14 Örebro, Sweden

P: +46 (0)19 21 83 00

F: +46 (0)19 27 23 77

E: johnson-pump.marine@spxflow.com

SPX FLOW, Inc. reserves the right to incorporate our latest design and

material changes without notice or obligation. Design features, materials

of construction and dimensionals data, as described in this bulletin, are

provided for your information only and should not be relied upon unless

confirmed in writing.

Please contact your local sales representative for product availability in

your region. For more information visit www.spxflow.com.

ISSUED 03/2016 JP-507/R03

COPYRIGHT ©2016 SPX FLOW, Inc.

SP Impeller Identification Guide

Recommended