View
213
Download
0
Category
Preview:
Citation preview
IND
EX
Clivet LiveAir quality
An intelligent heat pump
Advantages
Synoptic
Energy related Products
Guarantee and safety
Why Clivet
Clivet Home Specialized Systems ELFOPack
ELFOSystem Gaia Edition
ELFOSystem Gaia L Comfort
ELFOSystem Gaia L Hybrid
ELFOSystem Gaia Maxi Hybrid
ELFOSystem GAIA-i Comfort
ELFOSystem GAIA-i Hybrid
Transversal productsELFOControl2
ELFOFresh2
ELFOAir
ELFORoom2
Technical DataELFOPack
GAIA Aria
GAIA Acqua
GAIA L Comfort
GAIA L Hybrid
GAIA Maxi Hybrid Aria
GAIA Maxi Hybrid Acqua
GAIA-i
ELFOFresh2
ELFORoom2
ELFOAir
ELFOControl2
ELFOSun
ELFOEnergy Extended Inverter
System Scheme
0102
03
05
06
10
11
12
13
14
18
22
24
28
32
34
3839
40
42
43
4546
48
50
52
54
56
58
60
62
64
66
68
70
72
74
11
In order to satisfy residential comfort needs,Clivet has set up a new division of professionalsinspired by the principles embodiedby the acronym LIVE
LifeEnvironmentalsafeguard forour children’s future
VisionTechnology and systems to assure comfort and effi ciency
InnovationPassion and curiosityto guide innovation
EnergyProtagonistof the new energy era
Clivet Live is born
20
15
2
+
+
+
+
+
ELFOFresh2
+
+
+
+
+
+
ELFOFresh2
BUILDING INSULATIONThanks to new construction methods and improvements in building insulation, buildings are
extremely air tight. Contaminants stagnate in the environments and systems for air renewal
and purification become necessary.
INDOOR AND OUTDOOR POLLUTIONHuman health is severely damaged by the many indoor pollutants such as mold, smoke, dust,
CO2 emissions, and by external pollutants like pollen, PM10, viruses and bacteria.
MECHANICAL CONTROLLED VENTILATIONThe controlled mechanical ventilation system ensures a dilution of indoor pollutants. The inlet
fresh air is treated by recovering the heat from the extracted air. It is important the energy
recovery happens both in winter and in summer to reduce energy consumption.
ELECTRONIC FILTRATIONHarmful elements and odors in the outdoor air are removed thanks to the efficient
electronic filtration system, also active on fine particles and nanoparticles, the most
dangerous to human health as they reach the pulmonary alveoli and from there enter the
blood. The electrostatic filter, easily removable, is fully regenerable by washing.
Air quality: Fresh air is a fundamental need
CLIVET Controlled Mechanical Ventilation
Fresh air supply
Extraction
External air intake
Exhaust
FRESH AIR
THERMODYNAMIC HEAT RECOVERY
MAIN ENERGY SOURCE
ELECTRONIC FILTRATION
SMOKE - POLLEN - BACTERIA
PM10 - GERMS - VIRUSES
NANOPARTICLES - CO2
SUMMER DEHUMIDIFICATION
Clivet heat pumps:
HEATING
COOLING
DOMESTIC HOT WATER PRODUCTION
CONTROLLED MECHANICAL VENTILATION WITH THERMODYNAMIC HEAT RECOVERY
DEHUMIDIFICATION
ELECTRONIC FILTRATION
3
CONTROLLED MECHANICAL VENTILATION WITH THERMODYNAMIC HEAT RECOVERY
The controlled mechanical ventilation with
thermodynamic heat recovery is the original
solution developed by Clivet that provides
many benefits:
Energy advantages
Ventilation energy reduction thanks
to the lower pressure drops than
traditional recovery.
High efficiency energy recovery
from the exhaust air both in winter
and summer.
It multiplies the energy recovered
and fulfills the building thermal load.
It increases the seasonal efficiency
of the whole system, thanks to the
thermal source (exhaust air, always
at favorable temperature conditions)
of the heat pump, used as a
thermodynamic heat recovery system.
System advantages
It generates a first step of power and in
the middle seasons completely satisfies
the power required.
It reduces the load of the air-conditioning
system.
It eliminates the dehumidifier necessary
in radiant systems in cooling operation,
because it controls the summer humidity.
Comfort improvement
The external renewal air is supplied
at the ideal temperature for comfort
It compensates for the discomfort
generated from the thermal inertia of
the radiant system in spring and autumn.
Clivet thermodynamic heat recovery
increases the energy class of the building,
simplifies the system and improves
the comfort.
He
ati
ng
ca
pa
city
[kW
]
-4 0 5 10 15 20 25 30 35
THERMODYNAMIC HEAT RECOVERY
HEAT PUMP SYSTEM
Outdoor air temperature [°C]
-400
-200
0
200
400
600
800
1000
20%
80%
90%
-4
-3
-2
-1
0
1
2
3
4
5
-5 0 5 10 15 20 30 35
He
ati
ng
ca
pa
city
[kW
]
Outdoor air temperature [°C]
Ventilation load
System load
The thermodynamic heat recovery meets
all transmission and ventilation loads
25
THERMODYNAMIC HEAT RECOVERY
HEAT PUMP SYSTEM
4
MULTIFUNCTION UNIT
Issues related to the selection, installation and electric connection of a traditional system components are eliminated thanks to solutions that
are integrated in all the system elements already tested by Clivet.
Solar panels
Storage tank
Cross flow static passive recovery device
Boiler
1 unit
Solar panels
ELFOFresh2
GAIA
Air conditioner
Dehumidifier
TRADITIONAL SYSTEM
GAIA + ELFOFresh²
ELFOPack
THE COMPLETE CONTROL OF THE SYSTEM
The interface is simple and intuitive, limited only to comfort
settings required depending on the occupation and the
operation system display.
The advanced control logic is at the heart of Clivet systems.
It allows effective co-ordination of the dwelling system.
The distintive elements of Clivet systems
Thermal solar
Exhaust
External air intake
Extraction
Fresh air supply Radiant
module
Domestic hot water
ELFOControl2
ELFOFresh2
GAIA-i Comfort
ELFORoom2
l sola
Domestic hot water
air intake
Ex
FFFFFFresh air su
OFresh2
ar
Thermostats
for temperature
and humidity
5
COMPLETE SERVICES
Partner Clivet Comfort A +
Network of installers trained for high quality installations
SCHEDULED MAINTENANCE
To keep the plant effcient
QUALIFIED SERVICE
Widespread throughout the territory
Complete solutions, pre-assembled and integrated control of the entire
system are prerequisites to guarantee easy:
DESIGN: optimized solutions simplify the system
INSTALLATION: time reduction and quality installations
MANAGEMENT: one simple interface to set the desired comfort
MAINTENANCE: the integrated control connectivity allows a maintenance
service and remote assistance for a more efficient system.
Devices, developed to intelligently manage the energy and their
coordination according to the environmental conditions, allow:
• reduced operating costs
• maximum use of renewable energy
• environmental impact reduction
• increased value of the property
Systems developed according to the specific features of dwellings
and to the energy requirements needed at different seasons,
ensuring perfect comfort conditions.
ENERGY SAVINGS
COMFORT IN EVERY SEASON
SIMPLICITY
The specialized Clivet heat pump system advantages
PROFESSIONAL INSTALLATION
The Partners Clivet Comfort A + are a network of installers trained by Clivet. They take care of
the commercial proposal, installation, start-up and maintenance of the systems they have installed.
6
ELFOPack
ELFOPack
400 m3/h
100 m3/h
3 kW
180 L
DC InverterDC Inverter
ELFOAir
PATENTED
*
AP
PLI
CA
TIO
N
Houses
Air System
Nearly Zero consumption single-family houses
AIR
CO
ND
ITIO
NIN
G Heating
Cooling
DH
W
Domestic hot water
AIR
QU
ALI
TY
Mechanical ventilation with
thermodynamic recovery
Electronic fi ltration
MAX TOTAL AIR FLOW RATE
MAX AIRFLOW
CAPACITY
DHW STORAGE TANK
Summer dehumidifi cation
DIS
TR
IBU
TIO
N
Air distribution
and diff usion
CO
NTR
OL
System control
integrated into ELFOPack
Innovative product with seasonal effi ciency not covered by regulations
Independent heat pump home systems for single-family houses
7
ELFOSystem
GAIA
7÷16 kW
186 L
(+ 280 L aux)
DC InverterDC Inverter
GAIA L Comfort
5÷17 kW
280 L
(+ 280 L aux)
DC InverterDC Inverter
GAIA Maxi Hybrid
16 kW
(+ gen. aux 24 kW)
280 L
186 L
DC InverterDC Inverter
GAIA L Hybrid
5÷17 kW
(+ gen. aux 24 kW)
280 L
(+ 280 L aux)
DC InverterDC Inverter
ELFOFresh2
70-120-200-300-500-650 m3/h
ELFOControl2
Geothermal and Hydrothermal Integration to solar system Integrated condensation boilerAerothermal
Hydronic System
Medium-low consumption single-family houses High consumption single-family houses
CAPACITY
DHW STORAGE TANK
CAPACITY
DHW STORAGE TANK
CAPACITY
DHW STORAGE TANK
SYSTEM STORAGE
CAPACITY
DHW STORAGE TANK
AIRFLOW
ELFOSunconnectable to radiant panelsELFOAir ELFORoom2
8
ELFOPack
ELFOPack
400 m3/h
100 m3/h
3 kW
180 L
DC InverterDC Inverter
ELFOAir
PATENTED
*
Independent heat pump home systems for multi-family house applicationsA
PP
LIC
AT
ION
Houses
Air System
Nearly Zero consumption apartment building
AIR
CO
ND
ITIO
NIN
G Heating
Cooling
DH
W
Domestic hot water
AIR
QU
ALI
TY
Mechanical ventilation with
thermodynamic recovery
Electronic fi ltration
MAX TOTAL AIR FLOW RATE
MAX AIRFLOW
CAPACITY
DHW STORAGE TANK
Summer dehumidifi cation
DIS
TR
IBU
TIO
N
Air distribution
and diff usion
CO
NTR
OL
System control
integrated into ELFOPack
Innovative product with seasonal effi ciency not covered by regulations
9
ELFOSystem
GAIA-i Comfort
5÷8,5 kW
150 L
DC InverterDC Inverter
GAIA-i Hybrid
5÷8,5 kW
(+ gen. aux 24 kW)
150 L
DC InverterDC Inverter
ELFOFresh2
70-120-200-300-500-650 m3/h
ELFOControl2
Hydronic System
Medium-low consumption apartment building High consumption apartment building
CAPACITY
DHW STORAGE TANK
CAPACITY
DHW STORAGE TANK
AIRFLOW
Geothermal and Hydrothermal integration to solar system Integrated condensation boilerAerothermal
ELFOSunconnectable to radiant panelsELFOAir ELFORoom2
10
++
Energy related Products
The wide range of Clivet products and complete systems comply with the requirements of the implementing
measures for Directives 2009/125/EC (ErP-Energy related Products) and 2010/30/EU (Energy labelling), whose
purpose is to reduce the energy consumption of products for heating, cooling, ventilation and hot water
production, encouraging the user towards energy-effi cient choices.
With ELFOFresh2 and ELFOControl2 you can reach higher labelling levels than the the directives ones
CONTROLLED MECHANICAL VENTILATION WITH THERMODYNAMIC RECOVERY
11
Guarantee and safety
Become a specialistin renewable energysystems based on heat pump technologywith Clivet’s trainingprogrammes
The new era of sustainable comfort is challenging the traditional
design and installation approaches of building-plant systems.
Constantly updated standards require new buildings to have low
or almost zero consumption levels, which encourages the use
of renewable energies.
Systems are changing at a fast pace and must meet the new
requirements deriving from the evolution of an increasingly efficient
envelope.
New technologies require an initial investment in terms of knowledge
and training in order to build the skills to use innovative systems
focused on energy savings.
Through its CLIVET UNIVERSITY, Clivet intends to create a team
of trained professionals able to offer, design, install and conduct
maintenance on our solutions in order to ensure complete
customer satisfaction.
For more information and to book your place at one of the courses
held by CLIVET UNIVERSITY please visit our website www.clivetlive.com
Clivet UniversityClivet provides training classes to professionals willing to stand out in the field of innovative technologies
using renewable energies. The training programme, structured in different levels providing detailed
information, discusses annual-cycle systems based on heat pump technology.
Test roomsClivet pays great attention to the practical training of professionals who will offer, install and ensure
the maintenance of its products. That is why it has a series of test rooms for the simulation of the operation
of the plant in different climate and plant conditions that the installer could meet.
Partner Comfort A+Clivet, in order to develop the emerging market of the heat pump systems for residential, is training a
network of installers that are its specialists for technical and commercial capacities and innovation. Partners
Clivet Comfort A + are the only interlocutors for the commercial offer, installation, and maintenance
of systems. The goal is to combine professional competence of installers with the quality and experience
in the field of Clivet systems.
The coursesClivet offers a complete training catalogue for architects, mechanical engineers, installers, sales and
technical staff:
- Seminars for Designers and Architects on all year round comfort in the residential sector
- Basic courses for installers to introduce the basics of the innovative Clivet solutions
- Advanced Courses to examine the system’s components and installation features
- Specialised courses designed to provide training on installation, starting-up and maintenance
1212
Clivet. Change living homeWH
YC
LIV
ET
Clivet Home: a world of advantages,services and systems
Clivet Home, the application to which the Clivet Live division is dedicated, represents a new
comprehensive solution for the residential sector.
Indeed, Clivet Home autonomous heat pump systems:
• are tax deductible according to the countries
• guarantee an extensive range of services during the pre-sale phase, installation and throughout
the life-cycle of the plant, thanks to a network of specialized partners
• provide comprehensive solutions that simplify the design, installation and maintenance,
guaranteeing year-round comfort:
THE ADVANTAGES OF AN INDEPENDENT CLIVET HEAT PUMP SYSTEM
• heating
• cooling
• domestic hot water
• air renewal and purification
• humidity control
PLATINUM
GOLD
SILVER
Customer Care199 144 663 ITALY
+39 0439 313 888 WORLD
aftersales@clivet.it
Assistance
Green Building Council
A system for every need
A wide range of services
Professional installationProfessional installation
Tax credit
Certifications
CasaClimaEurovent
Medium-low consumption houses High consumption single-family houses
Apartment buildings
Due to its high efficiency, Clivet products may beeligible for heat pump subsidies in Your Country
14
ELFOPackNearly Zero consumption single-family housesand multi-family houses with stand-alone system
INSTALLATION EXAMPLE70 m2 FLAT
Exhaust
Stale air ejection
External air intake
Indoor air recirculation intake
Fresh air supply
Domestic hot water
AERAULIC DISTRIBUTION
Wide selection of accessories for air distribution
Thanks to special induction air diff users, supplied air mixes with the whole
mass of air already present in the room and creates a uniform temperature and
air quality in the entire room.
Controlled mechanical ventilation with thermodynamic heat recovery
Uses air renewal ducts for heating, cooling and summer dehumidifi cation
Max air renewal 100 m3/hfor houses up to 120 m2
ELFOPack main features
6 F
UN
CT
ION
S I
N A
SIN
GL
E P
AC
KA
GE
D U
NIT
Heating
Cooling
Summer dehumidifi cation
Domestic Hot Water Production
Air purifi cation withelectronic fi ltration
TH
E S
YS
TE
MS
page 74SYSTEM SCHEME
ELFOPack page 16
ELFOAir page 42
SYSTEM’S COMPONENTS
15
-50%
500
0
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
-50%
200
0
400
600
800
1000
1200
1400
-54%
200
400
600
800
1000
1200
0
5
4
3
2
1
THE RESULTS: comparison between ELFOPack and a traditional system
New multi-family building with 30 apartments of 75m2 in Class A.
Location: Milan
Climatic zone: 2404 GG
Insulation: opaque surfaces (0.34 W/m2k) and transparent surfaces (2.2 W/m2k)
Dispersant surfaces: vertical opaque envelope and transparent on two views, some internal
closures to unheated rooms
Air renewal rate: 0,3 vol/h
Traditional centralized system Centralized condensing boiler, centralized thermal solar system, centralized cooling with air/water chiller, decentralized CMV (passive recovery unit) for each fl at, radiant system, dehumidifi er
Centralized heat pump Centralized air/water heat pump for heating, cooling and DHW production. Decentralized CMV (ELFOFresh2 active recovery unit) for each fl at, radiant system
Data are referred to a single fl at.The running costs of systems also include the metering costs when compared with centralized systems.
CLIVET PATENTED SYSTEM
REDUCTION OF 30% ON THE VENTILATION ELECTRICAL ENERGYHigh effi ciency plug fans with DC motor, which guarantee a saving on electrical energy of up to 30% compared with the traditional AC fans. The DC motor allows the fan speed to be set to the real system pressure drops, thus minimising electrical consumption.
50% OF FREE DOMESTIC HOT WATERIntegrated 180-litre storage tank. The patented circuit allows the domestic hot water to be produced at high effi ciency in winter and free in summer. The innovative twin-wall exchanger improves the heat exchange effi ciency and avoids water contamination.
THERMODYNAMIC HEAT RECOVERYHeat recovery from the exhaust air both in winter and in summer by a thermodynamic circuit. The thermal source of the heat pump is fully maximised for effi ciency. Thanks to the mixture between the extracted stale air and the outdoor air. The air introduced in the room is a mixture between the fresh air and the recirculation air.
CAPACITY MODULATIONMAXIMIZED SEASONAL EFFICIENCIESThe inverter DC compressor adjusts the capacity according to system requirements optimizing the seasonal effi ciency.
HIGH EFFICIENCY ELECTRONIC FILTRATIONStandard electronic fi lters with fi ltration effi ciency higher than 99,9%. The electronic fi lter pressure drops are 90% lower than a traditional fi lter, allowing a considerable reduction in electrical energy used for ventilation.
Running costs [€/year]CO2 Emissions [kg CO
2/year]Primary energy [kWh/year]
ELFOPack (decentralized)Heat pump system (centralized)Traditional system (heating + cooling)
HIGH ENERGY EFFICIENCY
CLIVET PATENTED SYSTEM
1
2
3
4
5
16
In the stairwell
In the closet
It covers 75% of energy needs using free and unlimited renewable
energy contained in the air.
It recovers the energy from the exhaust air thanks to the active
thermodynamic heat recovery.
The mechanical controlled ventilation system is essential not only for energy saving, but also for a healthy environment.
The harmful elements and odors in the air are eliminated by the effi cient electronic fi ltration system
DESIGN FLEXIBILITY
On the balcony
It can be connected to Clivet ELFOAir distribution system
The low energy requirement of ELFOPack means that in some cases, where photovoltaic systems are installed, the energy generated is suffi cient to operate the ELFOPack system, helping the building to become self suffi cient
RISCALDAMENTO CON ELFOPack
RISCALDAMENTO TRADIZIONALE (radiante)
DISTRIBUTION
The air to air heat pump system with active thermodynamic heat recovery ELFOPack
COMFORT THROUGH THE AIR
PRO
DU
CTS
Continuous and rapid adaptation to the desired comfort
conditions.
Thanks to the lower thermal inertia, the air to air air-conditioning
system allows you to reach the desired comfort conditions in a much
shorter time than traditional air to water air-conditioning systems.
This feature is particularly appreciated in areas with frequent
temperature variations typical of Mediterranean climates.
10÷20 minutes
4÷6 hours
Cold sensation
Cold sensation
17
ADD VALUE TO YOUR PROPERTY
Thanks to the benefi ts detailed above and
the use of heat pump technology, ELFOPack
demonstrates reduced running costs and
energy consumption, which will contribute
to adding value to your property.
ELFOPack
Traditional system
(boiler - radiators - thermal solar)
The compressor adjusts its capacity, which is distributed to purify the air and constantly produce Domestic Hot Water. The constant and simultaneous production of Domestic Hot Water increases the system’s effi ciency. During extreme conditions, the post-handling coil is activated as an additional coil.
Intake air is dehumidifi ed as well as being treated and brought to the right temperature as a function of the load. The compressor adjusts its capacity in relation to indoor conditions. All the heat taken from cooling the intake air is recovered and transferred to produce free Domestic Hot Water.
Under optimal conditions, outdoor air is mixed with recirculated air to obtain the correct temperature, negating the need to activate the compressor (free-cooling).Domestic Hot Water is produced by turning off the supply air handling exchanger.
Standalone system, with one packaged unit. This means that there
is no requirement for a boiler, the associated pipework and the
control system.
Complete system, that removes the need for heat emitters, fancoil
units, radiators or radiant panels. The ELFOPack provides complete
comfort distributed through a simple ducted air system, off ering
complete design freedom.
Simple installation, due to its “plug and play” design, no specialist
trades are required for the installation of the unit. As there is no gas
requirement, this can also contribute to a reduction in the overall
build cost.
User friendly controller, off ers simple operation of the unit,
managing all aspects of the system from a single point.
Total safety, if combined with an induction hob cooker, the
requirement for gas can be removed from the installation, taking
away the need to install a gas main, and saving cost on the project,
as well as creating a gas free, safe environment.
ELFOPack page 46
WINTER SUMMER MID-SEASON
TECHNICAL DATA
18
Heating
Cooling
Systems up to 3 hydraulic circuits mixed/same
Ductable energy exchanger for internal installation
System with the highest seasonal effi ciency
ELFOSystem GAIA Editionmain features:
ELFOSystem GAIA EditionMedium-low consumption single-family houses
SYSTEM’S COMPONENTS
ELFOFresh2
ELFOControl2
ELFORoom2
Radiant panels
GAIA
Summer dehumidifi cation
Mechanical ventilation with thermodynamic heat recovery
Domestic hot water production
Air renewal and purifi cation with electronic fi ltration
ELFOControl2
TH
E S
YS
TE
MS
ELFOSystem GAIA Editionmain features:
External air intake
Exhaust
Extraction
Fresh air supply
Radiant module
Towel rail Towel rail
Thermostats for temperature and humidity
Thermostats for temperature
Outdoor air probe
Thermal solar
Energy exchanger
Domestic hot water
page 76SYSTEM SCHEME
GAIA page 20
ELFOFresh2 page 40
ELFOAir page 42
ELFORoom2 page 43
ELFOControl2 page 39
19
1
2
4
3
5
-49% -54%
18000
3000
6000
9000
12000
15000
0
-49% -54%
3500
3000
500
1000
1500
2000
2500
0
-45% -50%
1800
300
600
900
1200
1500
0
5
43
2
1
DOMESTIC HOT WATERIntegrated domestic hot water production with 186l boiler* and plate exchanger with a better exchange efficiency and maintenance.* (+ possible additional 280l boiler)
THERMAL SOLARIntegrated system of solar energy recovery from thermal collectors for free domestic hot water production.
RENEWABLE ENERGY INTEGRATED THERMODYNAMIC UNITAll hydraulic and control components are integrated and optimized by ensuring a perfect operation and high energy efficiency.
THE RESULTS: comparison between ELFOSystem GAIA Edition and a traditional system
Newly built single-family house of 270 m2, radiant panels, energy
requirements equivalent to 44kWh/m2 year in heating mode, 14kWh/m2
year in cooling mode, 4 occupants with 50l/person a day domestic hot
water consumption
Location: Milan
Climate zone: E – 2404 degrees by day
Number of rooms: 12
Surface: 270 m2
Running costs [€/year]CO2 emissions [kg CO
2/year]Primary energy [kWh/year]
HIGH EFFICIENCY DC INVERTER CIRCULATORThe DC INVERTER circulators automatically and continuously modulate the water fl ow rate according to the system load, reducing the distribution consumption.
EFFICIENT ENERGY GENERATIONThe DC Inverter compressor delivers only the required load, increasing the seasonal effi ciency.
HIGH ENERGY EFFICIENCY
ELFOSystem Gaia Edition + thermal solarELFOSystem GAIA EditionTraditional system
Traditional system Condensing boiler, radiant panels for heating, cross fl ow recovery device, split cooling system. Electric energy price 0,3/kWh
Impianto ELFOSystem GAIA Edition GAIA Aria 31, radiant panels for heating and cooling, ELFOFresh2 300, ELFOControl2. Electric energy price 0,22 €/kWh
Impianto ELFOSystem GAIA Edition GAIA Aria 31, thermal solar system, radiant panels for heating and cooling, ELFOFresh2 300, ELFOControl2. Electric energy price 0,22 €/kWh+ thermal solar
20
+70%
GAIA Aria recovers the energy available in the air thanks to the
ENERGY EXCHANGER, even an extreme outdoor air temperatures
down to -22 °C.
The large heat exchange surface helps increase the effi ciency of the system
The speed of the air fl owing through the heat exchanger is reduced to guarantee a quiet operation
The heat exchanger shape avoids any negative infl uences of prevailing winds
The special shape of the heat exchanger enables a reduction of the energy for the defrost cycles
The air diff user can be rotated to allow direct airfl ow in 4 diff erent positions
The fully plastic frame eliminates deterioration over time from corrosion
ENERGY EXCHANGER
REFRIGERANT LINESThe maximum distance between the two elements can be
up to 20 meters with a maximum diff erence in height of
15 meters.
(*) compared to a traditional unit, thanks to the generous dimensions of the exchanger and to an accurate defrost setting.
Free or ducted outlet
The air outlet may be
from any of the 4 sides
DEFROST CYCLE EFFICIENCY (*)
AEROTHERMALEXTERNAL INSTALLATION
INTERNAL INSTALLATION
Close to an external wall
In the attic
The air delivery duct and exhaust far from the dwelling
In the basement
PRO
DU
CTS
Integrated thermodynamic heat pump with high effi ciency energy exchanger
GAIA Aria page 48
TECHNICAL DATAGAIA Aria
21
1 2
9
8
7
5
8
69
3
4
HYDROTHERMALUSING
GROUNDWATER
GEOTHERMALENERGY RECOVERY FROM THE GROUND
In the Acqua version, GAIA off ers thermal and cooling energy
recovery for all applications using groundwater, well water or
geothermal systems.
GAIA Acqua is an extremely fl exible unit
The standard unit is fi tted with a source side DC motor circulating pump, which automatically modulates the water fl ow based on the temperature in order to optimise its performance.
The unit is sized to operate with geothermal probes or groundwater
The natural cooling function permits cooling without the need to activate the compressor (OPTIONAL).
Vertical collectors
Horizontal collectors
NATURAL COOLING FUNCTION
The low ground or groundwater temperature can be used to provide
free cooling in the home. All the components are inside free cooling
the unit.
PRO
DU
CTS
Integrated thermodynamic heat pump that recovers energy from the water
GAIA Acqua GAIA Acqua page 50
TECHNICAL DATA
1 cooled water delivery (system)
2 cooled water return (system)
3 user side heat exchanger
4 source side heat exchanger
5 source water return
6 source water delivery
7 natural cooling plate heat exchanger
8 3-way diverter valves
9 drain cocks
OPTIONAL
22
Primary pump included
External condensing unit
ELFOSystem GAIA L Comfortmain features
TH
E S
YS
TE
MS
ELFOSystem GAIA L ComfortMedium-low consumption single-family houses
Heating
Cooling
Summer dehumidifi cation
Mechanical ventilation with thermodynamic heat recovery
Domestic hot water production
Air renewal and purifi cation with electronic fi ltration
ELFOControl2
ELFOFresh2
GAIA L Comfort
ELFORoom2
Exhaust
External air intake
Extraction
Fresh air
supplyRadiant
module
Domestic
hot water
Thermostats for temperature and humidity
GAIA L Comfort page 26
ELFOFresh2 page 40
ELFOAir page 42
ELFORoom2 page 43
ELFOControl2 page 39
SYSTEM’S COMPONENTS
page 78SYSTEM SCHEME
23
5
4
3
2
18000
3000
6000
9000
12000
15000
0
-44% -49%
3500
1000
500
1500
2000
2500
3000
0
-44% -49%
1800
300
600
900
1200
1500
0
-40% -45%
1
5
4
3
2
1
1
2
3
45
3
VERSION WITH THERMAL SOLAR COLLECTORSGAIA L Comfort Solar (GLHS).
HIGH EFFICIENCY DC INVERTER CIRCULATOR
DOMESTIC HOT WATER STORAGE 280LPlate exchanger - electronic anode
PUMP FOR DOMESTIC WATER RECIRCULATION
HEAT PUMP WITH DC INVERTER COMPRESSOR
Running costs [€/year]CO2
emissions [kg CO2/year]Primary energy [kWh/year]
ELFOSystem GAIA EditionTraditional system GAIA L Comfort
150 m2 new single house, radiant panels, energy requirements
equivalent to 65kWh/m2 year in heating mode, 23kWh/m2 year
in cooling mode, 4 occupants with 50l/person a day domestic
hot water consumption
Location: Milan
Climate zone: E - 2404 degrees by day
Number of vans: 8
Surface 150 m2
Traditional system Condensing boiler, radiant panels for heating, cross fl ow recovery device, cooling split system. Electric energy price 0,3 €/kWh.
ELFOSystem GAIA L Comfort GAIA L Comfort 3.1, radiant panels for heating and cooling, ELFOFresh2 200, ELFOControl2. Electric energy price 0,22 €/kWh.
ELFOSystem GAIA Aria GAIA Aria 31, radiant panels for heating and cooling, ELFOFresh2 200, ELFOControl2. Electric energy price 0,22 €/kWh.
EXTERNAL UNIT: EFFICIENT AND QUIETCompact designSilenceDC Inverter compressorIce Protection System
THE RESULTS: comparison between ELFOSystem GAIA L Comfort and a traditional system
HIGH ENERGY EFFICIENCY
24
Primary pump included
Integrated condensing boiler
It satisfi es high domestic hot water consumption
ELFOSystem GAIA L Hybridmain features
TH
E S
YS
TE
MS
ELFOSystem GAIA L HybridHybrid high consumption single-family houses
Heating
Cooling
Summer dehumidifi cation
Domestic hot water production
Air renewal and purifi cation with electronic fi ltration
ELFOControl2
ELFOFresh2
GAIA L Hybrid
Thermostats
Radiant
module
Extraction
Fresh air
supplyRadiators
Domestic
hot water
ExhaustExternal air intake
Mechanical ventilation with thermodynamic heat recovery
GAIA L Hybrid page 27
ELFOFresh2 page 40
ELFOAir page 42
ELFORoom2 page 43
ELFOControl2 page 39
SYSTEM’S COMPONENTS
page 80SYSTEM SCHEME
25
1
5
4
3
2
45000
7500
15000
22500
30000
37500
0
-39% -44%
9000
1500
3000
4500
6000
7500
0
-39% -44%
4200
700
1400
2100
2800
3500
0
-35% -40%
1
2
3
4
5
VERSION WITH THERMAL SOLAR COLLECTORSGAIA L Hybrid Solar (GLHS).
HIGH EFFICIENCY DC INVERTER CIRCULATOR
DOMESTIC HOT WATER STORAGE 280LPlate exchanger - electronic anode.
PUMP FOR DOMESTIC WATER RECIRCULATION
HEAT PUMP WITH INTEGRATED CONDENSING BOILER
EXTERNAL UNIT: EFFICIENT AND QUIETCompact designQuietDC Inverter compressorIce Protection System
250 m2 existing single house, radiant panels with radiators in
integration and fancoil for cooling, energy requirements equivalent
to 98kWh/m2 year in heating mode, 32kWh/m2 year in cooling mode,
6 occupants with 50l/person day domestic hot water consumption
Location: Milan
Climate zone: E - 2404 degrees by day
Number of rooms: 12
Surface 250 m2
ELFOSystem GAIA MaxiGAIA L HybridTraditional plant
Running cost [€/year]CO2 emissions [kgCO
2/year] Primary Energy [kWh/year]
HIGH ENERGY EFFICIENCY
THE RESULTS: comparison between ELFOSystem GAIA L Hybrid and a traditional system
Traditional system Existing Boiler, radiators for heating, cooling split system. Electric energy price 0,3 €/kWh.
ELFOSystem GAIA L Hybrid GAIA L Hybrid 51, radiators and fan coil, ELFOFresh2 200, ELFOControl2. Electric energy price 0,22 €/kWh.
ELFOSystem GAIA Maxi Aria GAIA Maxi Aria 61, radiators and fan coil, ELFOFresh2 200, ELFOControl2. Electric energy price 0,22 €/kWh.
ELFOSystem GAIA MaxiTraditional plant
26
IDEAL FOR LOW-TEMPERATURE SYSTEM
It is the high effi ciency heat pump with 280l storage tank, which
off ers high seasonal effi ciency thanks to the possibility of modulating
the capacity according to the actual energy needs.
Since the maximum power
generated by the system is
required only for short periods
of time, it is fundamental
to dispose of the maximum
effi ciency in the conditions of
part-load. This is the only way
to actually reduce overall yearly
consumptions.
Thanks to automatic capacity
modulation, the direct current
inverter compressor supplies
only the thermal energy that
is needed, thereby avoiding
wasting energy and increasing
the energy effi ciency so
that the exchange surfaces
are larger in relation to the
output capacity.
GAIA L COMFORTSOLAR
Version for connection with thermal solar systems
Maximum seasonal effi ciency thanks to the regulation, which manages all the heat pump functions
It satisfi es 100% needs with the heat pump
User friendly menu for a simple plant regulation
Quiet and effi cient external unit with DC inverter compressor
CAPACITY MODULATION
Heat pump with integrated hot domestic water storageGAIA L Comfort
PRO
DU
CTS
GAIA L Comfort page 52
TECHNICAL DATA
COP 2,5
COP 2,7
COP 3
COP 3,1
COP 3,5
COP 4,9
External air temperature (°C)
External air temperature (°C)
Heat pumpCompressorOn-Off
GAIA LDC inverter Compressor
Thermal load
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
0
50
100
150
200
250
300
350
-5 0 5 10 15 20
-5 0 5 10 15 20
2
0
2
2
8
10
12
14
He
ati
ng
ca
pa
city
[kV
Vt]
CO
P
Ho
urs
of
the
occ
urr
en
ce o
f sp
eci
fic
ou
tsid
e t
em
pe
ratu
re
Inverter modulation zone
GAIA L works for most of the time
with COP between 3 and 5
COMFORT AND SEASONAL EFFICIENCY
SEASONAL EFFICIENCY
27
The system control favours
the use of the heat pump,
exploiting the maximum
quantity of renewable energy.
If the required load is higher
than the power generated
by the heat pump, it activates
the condensing boiler.
The system can also be
programmed so that the boiler
takes the place of the heat
pump taking into account the
two energy costs.
GAIA L HYBRIDSOLAR
Version for connection with thermal solar systems
Maximum seasonal effi ciency thanks to the regulation which manages all the heat pump functions
The condensing boiler satisfi es high energy demands
Quiet and effi cient external unit with DC inverter compressor
IDEAL FOR LOW-TEMPERATURE PLANTS
It is the hybrid heat pump ideal for houses with high energy
requirements. The indoor unit is equipped with a modulating
condensing boiler for integration both with the plant and with the
domestic hot water. It is possible to supply traditional radiators with
water up to 80 °C at -20 °C external air temperature.
INTEGRATION BOILER
SUBSTITUTION BOILER
User friendly menu for simple control
GAIA L Hybrid
PRO
DU
CTS
Heat pump and condensing boiler with integrated hot domestic water storage
GAIA L Hybrid page 54
TECHNICAL DATA
He
ati
ng
ca
pa
city
[kW
h]
30282624222018161412
4038363432
1086420
-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 1514
External air temperature (°C)
Boiler
Heat pump
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 1514
External air temperature (°C)
Boiler
Heat pump
He
ati
ng
ca
pa
city
[kW
h]
HEAT PUMP AND BOILER
28
ELFOControl2
Systems up to 4 circuits at high capacity requested
Ductable energy exchanger also for internal installation
Solar thermal for integration to plant and domestic hot water
ELFOSystem GAIA Maxi Hybrid main features
TH
E S
YS
TE
MS
ELFOSystem GAIA Maxi HybridHigh consumption single-family houses
SYSTEM’SCOMPONENTS
ELFORoom2
ELFOControl2
GAIA Maxi Hybrid
Radiant panels
ELFOFresh2
Heating
Cooling
Summer dehumidifi cation
Domestic hot water production
Air renewal and purifi cation with electronic fi ltration
Mechanical ventilation with thermodynamic heat recovery
t l2
GAIA Maxi Hybrid page 30
ELFOFresh2 page 40
ELFOAir page 42
ELFORoom2 page 43
ELFOControl2 page 39
SYSTEM’S COMPONENTS
page 82SYSTEM SCHEME
29
50000
10000
20000
30000
40000
0
-44% -51%
10000
2000
4000
6000
8000
0
-44% -51%
5000
1000
2000
3000
4000
0
-41% -48%
GAIA, THE FULL INVERTER DC HEAT PUMPThe heart of GAIA Maxi Hybrid is GAIA, the heat pump for heating, cooling and producing domestic hot water that applies DC Inverter Technology to compressor, fan, circulators to supply the exact capacity requested with the highest effi ciency possible.
DRAIN THERMAL SOLARThe GAIA Maxi Hybrid integrated “Drain Back” drain solar system exploits the solar contribution for the production of DHW and integration on the heating system.
HIGH EFFICIENCY DIRECT CURRENT SECONDARY CIRCULATORS
186-LITRE SYSTEM STORAGE TANK
280-LITRE DOMESTIC STORAGE TANK
HIGH EFFICIENCY DIRECT CURRENT PRIMARY CIRCULATOR
Running cost [€/year]CO2 emissions [kgCO
2/year] Primary Energy [kWh/year]
Requalifi cation of single-family house of 400 m2, radiant panels
and radiators, energy requirements equivalent to 75kWh/m2 year
in heating mode, 24kWh/m2 year in cooling mode, 6 occupants
with 50l/person day domestic hot water consumption.
Location: Milan
Climate zone: E – 2404 degrees by day
Number of rooms: 12
Surface 400 m2
CONDENSING BOILERWhen the heating occupancy of the heat pump is insuffi cient, GAIA Maxi Hybrid uses the condensing boiler for the production of hot water for heating and for domestic use.
HIGH ENERGY EFFICIENCY
THE RESULTS: comparison between ELFOSystem GAIA Maxi Hybrid and a traditional system
Traditional system Existing Boiler, radiant panels and radiators, cross fl ow recovery device, cooling split system. Electric energy price 0,3 €/kWh.
ELFOSystem GAIA Maxi Aria GAIA Maxi Aria 61, radiant panels and radiators, 2 x ELFOFresh2 300, ELFOControl2. Electric energy price 0,22 €/kWh.
ELFOSystem GAIA Maxi Aria GAIA Maxi Aria 61, thermal solar system, radiant panels and radiators, 2 x ELFOFresh2 300, ELFOControl2. + thermal solar Electric energy price 0,22 €/kWh.
ELFOSystem GAIA Maxi + thermal solarELFOSystem GAIA Maxi AriaTraditional system
1
2
3
4
6
7
5
2 4
6
7
3
5
1
30
GAIA Maxi Aria recovers the energy available in the air through
the ENERGY EXCHANGER even at extreme outdoor air temperatures
down to -22 °C.
The large heat Exchange surface helps increasing the effi ciency of the system
The speed of the air fl owing through the heat exchanger is reduced to guarantee a quiet operation
The heat exchanger shape avoids any negative infl uences of prevailing winds
The special shape of the heat exchanger enables reduced energy for the defrost cycles
The air diff user that can be rotated to direct the airfl ow
The fully plastic frame eliminates deterioration over timefrom corrosion
REFRIGERANT LINESThe maximum distance between the two elements can be
20 m, with a maximum 15 m of height diff erence.
The connection between GAIA Maxi and the Energy Exchanger is of cooling type, avoiding any risk of freezing.
Ducted or free
outlet supply
The exhausted air can be
discharged on any of the 4 sides
AEROTHERMALINSTALLED OUTSIDE
INSTALLED INSIDE
Close to an external wall
In the attic
Delivery duct and exhaust far from the dwelling
In the basement
PRO
DU
CTS GAIA Maxi Hybrid
Combined energy thermodynamic packaged unit: thermal solar, heat pump, condensing boiler. Aerothermal version (GAIA Maxi Aria) Idrothermal version (GAIA Maxi Acqua)
ENERGY EXCHANGER
31
THERMAL SOLAR INTEGRATED TO SYSTEM
ADAPTABLE TO EVERY INSTALLATION REQUIREMENT
During the heating season, when the request for domestic hot water is satisfi ed, GAIA Maxi is able to use
the heat energy captured by the solar panels and stored in the domestic storage tank to satisfy the system’s
request.
Heat pump module and domestic hot water module installed separately
along diff erent walls.
GAIA Maxi has been designed for connection to thermal solar
panels to further increase the use of renewable sources for the free
production of domestic hot water and for the heating system.
Coverage of the heat energy requirement for the domestic hot
water, captured through the thermal solar panels, is equal to
75%, the remainder only necessary during the winter months,
is provided by the heat pump.
The GAIA Maxi integrated “Drain Back” drain system, diff erentiates from the traditional
forced circulation systems in the managing of the inactive phases during which
the solar circular can be drained to off er the necessary protection against risk of
over-temperatures or freezing. When the temperature of the water in the solar panels
is too high, the GAIA Maxi control stops the solar pump to drain the circuit and
protect the panels from the stagnation phenomena. Draining also happens in case
of low temperatures, in this way protecting the solar panel against the risk of its
vector fl uid freezing.
Heat pump module and domestic hot water module installed separately
along the same walls.
Energy provided by the Heat Pump for domestic hot water production
Energy provided by thermal collectors for heating
Energy provided by thermal collectors for domestic hot water
Energy is not fi ltered through the Drain Back system
INTEGRATED SOLAR DRAIN BACK
0
100
200
300
400
500
FebruaryMarch
April MayJune
July
August
September
October
November
December
600
He
ati
ng
ca
pa
city
[kW
h/a
nn
o]
January
IT SATISFIES OVER 70% OF THE REQUIREMENT
GAIA Maxi page 56TECHNICAL DATA
32
TH
E S
YS
TE
MS
Medium-low consumption apartment building
Heating
Domestic hot water Production
Summer dehumidifi cation
Cooling
Air renewal and purifi cation with electronic fi ltration
Mechanical ventilation with thermodynamic heat recovery
Thermal solar
Exhaust
External air intake
Extraction
Fresh air supply Radiant
module
Domestic hot water
ELFOControl2
ELFOFresh2
GAIA-i Comfort
ELFORoom2
l sola
Domestic hot water
air intake
Ex
FFFFFFFresh air su
OFresh2
ar
Thermostats
for temperature
and humidity
Systems up to 2 hydraulic circuit
mixed and not
Uncased unit in only 35 cm
ELFOSystem GAIA-i Comfort main features
ELFOSystem GAIA-i ComfortGAIA-i Comfort pag. 36
ELFOFresh2 pag. 40
ELFOAir pag. 42
ELFORoom2 pag. 43
ELFOControl2 pag. 39
SYSTEM’S COMPONENTS
33
2500
5000
7500
0
-44% -49%10000
12500
400
800
0
-44% -49%1200
1600
2000
2400
200
0
-40% -45%
400
600
800
1000
1200
2
4
3
5
1
1
2
3
4
5
THE RESULTS: comparison between ELFOSystem GAIA Maxi and a traditional system
ELFOSystem GAIA AriaELFOSystem GAIA i Comfort Traditional system
EXTERNAL UNIT: EFFICIENT AND SILENTCompact designSilenceDC Inverter compressorIce Protection System
DC INVERTER COMPRESSOR HEAT PUMP
HIGH EFFICIENCY CIRCULATOR
VERSION WITH THERMAL SOLAR COLLECTORS
PUMP FOR DOMESTIC WATER RECIRCULATION
CONFIGURATION MODULARITYModules can also be placed at diff erent times to meet system needs.
HIGH ENERGY EFFICIENCY
100 m2 new fl at, radiant panel system, energy requirements
equivalent to 54kWh/m2 year in heating mode, 25kWh/m2 year
in cooling mode, 4 occupants with 50l/person a day domestic
hot water consumption
Location: Milan
Climate zone: E - 2404 degrees by day
Number of rooms: 6
Surface 100 m2
THE RESULTS: comparison between ELFOSystem GAIA-i Comfort and a traditional system
Traditional system Existing Boiler, thermal solar, radiant panels for heating, cross fl ow recovery device, cooling split system. Electric energy price 0,3 €/kWh. (D3 Tarif )
ELFOSystem GAIA-i Comfort GAIA-i Comfort 2.1, radiant panels for heating and cooling, ELFOFresh2 120, ELFOControl2. Electric energy price 0,22 €/kWh. (D1 Tarif )
ELFOSystem GAIA Aria GAIA Aria 31, radiant panels for heating and cooling, ELFOFresh2 120, ELFOControl2. Electric energy price 0,22 €/kWh (D1 Tarif )
Annual running cost [€/year] CO2
emissions [kgCO2/year]Primary Energy [kWh/anno] /year]
34
TH
E S
YS
TE
MS
Exhaust
External air intake
Extraction
Fresh air supply Radiant
module
Domestic hot water
Radiators
ELFOControl2
ELFOFresh2
GAIA-i Hybrid
ELFORoom2
Domestic hot water
Radiators
air intake
Ex
FFFFresh air su
OFresh2
rs
Thermostats
for temperature
and humidity
ELFOSystem GAIA-i HybridHigh consumption apartment building
Heating
Domestic hot water Production
Summer dehumidifi cation
Cooling
Air renewal and purifi cation with electronic fi ltration
Mechanical ventilation with thermodynamic heat recovery
Systems up to 2 hydraulic circuitmixed and not
Integrated condensing boiler
Uncased unit in only 35 cm
ELFOSystem GAIA Maxi main features
SYSTEM’S COMPONENTS
GAIA-i Hybrid pag. 36
ELFOFresh2 pag. 40
ELFOAir pag. 42
ELFORoom2 pag. 43
ELFOControl2 pag. 39
35
2
4
3
5
1
1
2
3
4
5
3300
6600
9900
0
-41% -47%13200
19800
16500
600
1200
0
-41% -47%1800
2400
3000
4200
3600
330
0
-36% -42%
660
990
1320
1650
1980
Running cost [€/year]
HIGH ENERGY EFFICIENCY
THE RESULTS: comparison between ELFOSystem GAIA Maxi and a traditional system
ELFOSystem GAIA Maxi + thermal solarELFOSystem GAIA-i HybridTraditional system
DC INVERTER COMPRESSOR HEAT PUMP
HIGH EFFICIENCY CIRCULATOR
PUMP FOR DOMESTIC WATER RECIRCULATION
CONFIGURATION MODULARITYModules can also be placed at diff erent times to meet system needs.
VERSION WITH THERMAL SOLAR COLLECTORS
EXTERNAL UNIT: EFFICIENT AND SILENTCompact designSilenceDC Inverter compressorIce Protection System
Annual running cost [€/year] CO2 emissions [kgCO
2/year]Primary Energy [kWh/anno] /year]
120 m2 old fl at, heating plant with radiators integrated with fan coil for
cooling, energy requirements equivalent to 89kWh/m2 year in heating
mode, 29kWh/m2 year in cooling mode, 4 occupants for domestic
hot water consumption
Location: Milan
Climate zone: E - 2404 degrees by day
Number of rooms: 7
Surface 120 m2
I RISULTATI: comparison between ELFOSystem GAIA-i Hybrid and a traditional system
Traditional system Existing Boiler, radiators for heating, split system for cooling. Electric energy price 0,3 €/kWh. (D3 Tarif ).
ELFOSystem GAIA-i Hybrid GAIA-i Hybrid 3.1, radiators and fan coil, ELFOFresh2 200, ELFOControl2. Electric energy price 0,22 €/kWh. (D1 Tarif )
ELFOSystem GAIA Aria GAIA Maxi Aria 61, radiators and fan coil, ELFOFresh2 200, ELFOControl2. Electric energy price 0,22 €/kWh (D1 Tarif )
36
PRO
DU
CTS GAIA-i
Uncased heat pump with integrated hot domestic storage
SEQUENCE OF INSTALLATION
Positioning of the recessed cabinet in the wall
Connection of the plant to the attacks
Installation and connection of the selected modules according to the choices
GAIA-i Comfort
GAIA-i Hybrid
GAIA-i is a confi gurable system with several modules which allow
maximum fl exibility of installation choices and the integration of
diff erent energy sources: solar,heat pump,fuel.
Through the composition of the diff erent modules it is possible to
create the following BASIC versions of the product:
Heat pump with integrated hot domestic storage
Heat pump with condensing boiler for integration with integrated
hot domestic storage
Heat pump can satisfy completely the plant load. It is possible
to use an optional electric heater in integration that allows a better
sizing and operation of the heat pump without compromising
the seasonal effi ciency.
The control allows to manage the integrated boiler in the GAIA-i
either as a integration or a replacement of the heat pump,
according to system type, heating requirements and energy costs.
The integrated condensing boiler is modulating.
He
ati
ng
Ca
pa
city
[kW
h]
0
1
3
2
4
5
6
-15 -13 -11 -9 -7 -5 -3 -1 1 3 5 7 9 11 13 15
Outdoor air temperature (°C)
Electric heater
Heat pump
He
ati
ng
Ca
pa
city
[kW
h]
02468
10121416
18
20
22
24
2830
26
22
24
28
30
26
-15 -14 -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 7 6 5 4 3 2 1
Outdoor air temperature (°C)
Heat pump or boiler
Boiler
Heat pump
37
1
3
4
5
2
1 2
3
5
4
6
7
8
9
11
10
6
7
8
9
1011
GAIA-i enables the realization of a system with the full integration of the hydraulic components inside
the uncased unit built in just 35cm depth.
The diff erent modules are pre-assembled and tested. They can be installed in diff erent moments
according to the building realization timing. Each module is designed to simplify and speed up
installation time.
SIMPLIFIED CONTROL
Room humidity and temperature Touch-screen display
Ambient temperatureSystem hour
Delivered capacity level
Integration generator status (if present)
DHW production activation
Stato della resistenzain integrazione (se presente)
On/Off scheduling menu
Weekly scheduling
Setting
Operating status
DHW set point
Signalling/Alarms
MODULARITY
150-L DHW STORAGE TANK
DHW EXPANSION TANK
HYDRONIC MODULE WITH ELECTRICAL PANEL
UNCASED CABINET WITH JIGS FOR FITTINGS AND CONDENSATE COLLECTION TRAY
SYSTEM EXPANSION TANK
CCGIXIntegration condensing boiler
KDSRXCircuit breaker and booster management board
KIRHXHigh temperature booster kit
KIRLXMixed booster kit
KSOLXSolar kit
EHR246X2-4 kW system integration electric heater as an alternative to the boiler (CCGIX)
GAIA-i page 60
TECHNICAL DATA
38
1 2 3
Clivet residential systems generate comfort using heat pump technology for the diff erent applications.
ELFOPack is composed by a single unit that satisfi es all comfort needs.
ELFOSystem GAIA Edition, ELFOSystem GAIA L Comfort, ELFOSystem GAIA L Hybrid and
ELFOSystem GAIA Maxi Hybrid systems consist of a heat pump specifi c for each system for heating,
cooling and domestic hot water production (GAIA, GAIA L Comfort, GAIA L Hybrid and GAIA Maxi)
and three transversal elements:
PR
OD
UC
TS
Transversal products
Air renewal
and purifi cation unit
ELFOFresh2
Terminal unit
for the distribution
ELFORoom2
Control system
ELFOControl2
ELFORoom2
ELFOFresh2
ELFOAir
ELFOControl2
Air renewal and purifi cation
Air distribution
Terminal units
System control
SYSTEM HEAT PUMP
TRANSVERSAL COMPONENTS
ELFOControl2 ELFOFresh2 ELFOAir ELFORoom2
ELFOPack ELFOPack — — —
ELFOSystem GAIA Edition GAIA
ELFOSystem GAIA Maxi Hybrid GAIA Maxi
ELFOSystem GAIA L Comfort GAIA L Comfort
ELFOSystem GAIA L Hybrid GAIA L Hybrid
39
It manages up to 12 elements simultaneously
Set diff erent temperatures inside the same climate area - FIG. 1
Set the temperatures directly from “touch” screen or from the thermostat
Up to 10 customised timed programming for optimising the functioning and effi ciency of the entire system - FIG. 2
TEMPERATURE AND HUMIDITY ROOM BY ROOM MANAGEMENT
HID-T5 thermostat, with a modern design, is equipped with a colour
touch screen display that allows, thanks to its extremely intuitive graphic,
to easily manage the comfort parameters.
FIG. 1 FIG. 2
In case there is a radiant installation used also for cooling purposes,
the humidity control is made by ELFOFresh2, while the water
temperature of the water produced by GAIA is defi ned based
on the outdoor temperature and modifi ed based on dew point
through the humidity level measured by the themostats.
Each of us diff erently perceives well-being, for this reason it is not
easy to defi ne comfort. ELFOControl² allows the user to adjust all
system settings and adjustments, even the most advanced, to its
own requirements, to guarantee everyone with the ideal comfort.
PRO
DU
CTS
The entire system at your fi ngertipsELFOControl2
Even the best cooling system without correct temperature control
can generate discomfort instead of comfort, with ELFOControl2
it is suffi cient a simple touch screen to access the control of each
single ELFOSystem part. ELFOControl2 controls and manages
the whole system smartly and effi ciently to give always the best
comfort at the lower cost.
ELFOControl2 page 68
TECHNICAL DATA
RADIANT CONTROL IN COOLING
40
PRO
DU
CTS
New, clean and fresh air at homeELFOFresh2
ELIMINATES POLLUTANTS
ELFOFresh2 rejects the stale air and introduces purifi ed and
conditioned fresh air. The harmful elements and smells present
in the outdoor air are eliminated by the effi cient fi ltration system.
The electrostatic fi lter is easy to extract and can be fully restored
by washing.
HUMIDITY CONTROL
During summer operation ELFOFresh2, cooling the air renewal,
dehumidifi es the air increasing comfort. The use of ELFOFresh2 in
cooling systems using underfl oor, wall or ceiling heating, makes it
unnecessary to install the dehumidifi er. In winter operation, thanks
to the use of accessories dedicated, ELFOFresh2 maintains a correct
humidity value.
ELFOFresh2 off ers extraordinary energy effi ciency, since it operates with an heat source, the exhaust air from the building,
which is always better than outdoor air. During the winter, for example, it uses the exhaust air which is around 20°C,
guaranteeing a COP of over 5,5. ELFOFresh2 reduces the ventilation load supplies additional energy, helping to maintain
comfortable conditions. The result is an up to 40% reduction in primary energy consumption in heating mode compared
to a traditional system.
IT INCREASES THE BUILDING ENERGY CLASS
It can be connected to Clivet ELFOAir distribution system
DISTRIBUTION
Energy rating according to national guidelinesThe example provided refers to:
LOCATION: Milan, Climate Zone E (2404 GG). Single dwelling.
SURFACE AREA: 200 m2;
GROSS HEATED VOLUME: 600 m3
EXTERNAL WALL AREA: 440 m2;
RATIO S/V: 0.73 m-1
OUTER INSULATION: compliance with legal transmittance value (Uwalls: 0.34; Uroof: 0.30; Ufl oor: 0.33; Uwindows: 2.2 W/m2 K).
41
+ Summer and winter active
thermodynamic heat recovery
and 80% building energy
satisfaction
+ Electronic fi ltration
+ Summer dehumidifi cation
+ Free cooling
ELFOFresh2 page 62
THERMODYNAMIC HEAT RECOVERY
ELFOFresh2 off ers active thermodynamic heat recovery both in
summer and in winter. It is equipped with high effi ciency fi nned
coils and guarantees very low pressure drops throughout the
entire operating cycle, noticeably reducing the energy used
for ventilation.
Traditional static recovery devices are subject to burdensome
air fl ow pressure drops.
They constantly hinder ventilation, generating higher electricity
consumption and doing away with much of the energy eff ectively
recovered over the year.
WINTER OPERATION
The indoor air (A), extracted from the most dirty and humid as bathrooms and kitchen, fl ows through the evaporator coil (B) and transfers heat to the heat pump. Only then it is rejected (C). After having taken energy from the exhaust air, the refrigerant in the heat pump transfers it through the condenser coil (E) to the outdoor fresh air (D) before being introduced in the room (F), before the inlet in the living room and bathrooms.
SUMMER OPERATION
The cooling cycle is inverted thanks to the 4-way valve, so that the “cold” contained in the exhaust air (A) is recoverd in the condenser coil (B) before the air is rejected (C). The outdoor air (D) is fi ltered and then cooled and dehumidifi ed, passing through the evaporator (E) before being introduced into the room (F).
FREE COOLING : FREE COMFORT
During mid-seasons, the climate may be more pleasant outside than inside, especially in the evening. In these situations, the clever design of ELFOFresh2 allows to keep the required conditions in the rooms using outdoor air at no cost just using the fan.
TECHNICAL DATA
42
Flexible in installation thanks to the use of fl exible and usable ducts
Air quality assured by the use of antistatic and antibacterial ducts
Simple in selecting the components and in the installation
Homogenous air diff usion thanks to the specialdiff users AIRJET
ANTISTATIC AND ANTIBACTERIAL
The inner surface of the fl exible ducts is lined with a special plastic fi lm
treated with silver ions that provides excellent antistatic and antibacterial
properties and guarantees top hygiene levels of the treated air. Furthermore the internal smooth surface of the ducts ensures low pressure drops
and therefore reduces consumptions for ventilation.
PRO
DU
CTS
The air distribution system for ELFOFresh2 and ELFOPackELFOAir
In new buildings and redevelopment works on existing buildings
ELFOAir is the best solution to fully enjoy the benefi ts of the ELFOFresh2
ventilation system or ELFOPack thanks to its stepped fl exible ducts.
These are ideal for underfl oor applications, as well as for installations in
attics and false ceilings. Specially designed grids and outlets can also
be fi tted and can be perfectly integrated in any kind of architectural
context. The modular system ELFOAir with Plug&Play connection of the
diff erent elements makes the system extremely easy and quick to install.
ELFOAir page 66
TECHNICAL DATA
Thanks to special induction air diff users, supplied air imperceptibly
involves the whole air already present in the ambient and creates a uniform
temperature and air quality in the entire room.
Th k i l i d i i diff li d i i ibl
43
Uniform temperature
Lower energy consumptions
Less noise
Large and easy to access fi lter
The continuously running fan allows to operate the fan coil at very low
speeds, making the noise that it produces almost imperceptible.
ELFORoom2 is equipped with a control system that permits the continuous adjustment
of the rpm to suit the system requirements.
In addition to its complete and fl exible temperature control, ELFORoom2
also takes care of air quality. In fact, it is equipped with a large fi lter,
easily accessible via the front panel, which ensures effi cient air purifi cation
and makes it possible to reduce cleaning operations.
Thanks to the continuous fan operation and the gradual speed
variations, ELFORoom2 guarantees constant air movement.
The exclusive fan electric motor of the ELFORoom2 guarantees
low energy consuptions thanks to the modulation of ventilation.
The innovative technological solution considerably limits the
energy generated for its correct operation, reducing the required
power and the operating costs if compared to the traditional
fan coils.
QUIET OPERATION
IT CLEANS THE AIR AS IT CONTROLS THE TEMPERATURE
Consistently uniform temperature and lower energy consumptionELFORoom2
PRO
DU
CTS
ELFORoom2 page 64
TECHNICAL DATA
0
0% 100%
10
Po
we
r in
pu
t [V
V]
20
30
40
50
Speed variation
1° Vel.
2° Vel.
3° Vel.
Traditional Fan Coil
ELFORoom2 DC motor
45
Data contained in this catalogue are not binding and may be changed by the Manufacturer without notice.
No part of this publication may be reproduced.
Updated data available on www.clivetlive.com
TE
CH
NIC
AL
DA
TA
Technical Data
name series from to page
Heating, cooling, air renewal and domestic hot water production
ELFOPack CPAR-XIN 3,2 - kW/t 46
Production of thermal and cooling energy
GAIA Aria MSER-XEE 7,3 16 kW/t 48
GAIA Acqua WSHR-XEE 8,4 15,7 kW/t 50
GAIA L Comfort GLC 5,19 17 kW/t 52
GAIA L Hybrid GLH 5,19 17 kW/t 54
GAIA Maxi Aria MSER-XIN 16 - kW/t 56
GAIA Maxi Acqua WSHR-XIN 15,7 - kW/t 58
GAIA i GIGA 5 8 kW/t 60
ELFOEnergy Extended Inverter WSAN-XIN 3,88 49,2 kW/t 72
Air renewal and purification
ELFOFresh2 CPAN-U 70 650 m3/h 62
Distribution
ELFORoom2 0,8 3,8 kW/t 64
ELFOAir 66
Control
ELFOControl2 68
Solar panel
ELFOSUN 70
46
(CPAR-XIN 5)ELFOPack
PATENTED
53,183,832,142,95400100300
120ROT DC inverter
18040/601,20
230/1/50
TEC
HN
ICA
L D
ATA
TECHNICAL DATA
Size – CPAR-XIN Heating capacity (1) kWThermodynamic SCOP (2) - Cooling capacity (3) kWThermodynamic SEER (2) -
Maximum air flow rate in the room m³/hMaximum air flow taken from the bathrooms and the kitchen m³/hMaximum air flow of internal ambient recirculation m³/hMaximum air flow air intake from outside m³/h 400 of which 100 fresh airMaximum air flow of outside expelled air m³/h 400 of which 100 extraction airAvailable head PaCompressor type (4) -DHW tank lDHW tank temperature °C Safety electric heater kWStandard power supply V/f/Hz
Notes
(1) Overall heating capacity for transmissions + ventilation + domestic hot water production (4 people - 50 litres/day per person). Conditions: outdoor air 7°C DB, 6.1°C WB, renewal and recirculation stale air 20°C DB.
(2) SCOP / SEER average thermodynamic seasonal efficiency of a home in Milan with an overall demand for transmissions, ventilation and domestic hot water (4 people - 50 litres/day per person) equal to the overall heating capacity provided by ELFOPack as per project specifications (-5°C). The average thermodynamic seasonal efficiency does not take into account the energy absorbed by the fans, as it depends on the pressure drops of the aeraulic distribution of each specific installation.
(3) Total cooling capacity for transmissions + ventilation. Production of domestic hot water (4 people - 50 litres/day per person) with total recovery. Conditions: outdoor air 35°C DB, renewal and recirculation stale air 26°C DB.
(4) ROT DC Inverter = DC Inverter rotary compressor
47
300
20
20
C
AB
30
600
b ac d e
Size - CPAR-XIN 5A - Length mm 812B - Width mm 460C - Height mm 2180Operating weight kg 400
CAUTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.
(a) Exhaust outdoors (b) Stale air extraction (bathrooms and kitchen)(c) Supply into the room (d) Fresh air intake (e) Indoor air recirculation intake
Air-air reversible heat pump with active thermodynamic heat recovery
Refrigerant R-410A
DIMENSIONS
Full Inverter DC
The above mentioned data are referred to standard units.
Active therm.recovery
ACCESSORIES
Size – CPAR-XIN 5Basic configuration (230/1/50) std
HIDTi52BX Temperature and humidity thermostat / Remote keyboard with touch display for recessed (box 503) or wall mounting. White
HIDTi52NX Temperature and humidity thermostat / Remote keyboard with touch display for recessed (box 503) or wall mounting. Black
AL12X Power supply unit for HID-Ti5 thermostats and HID-UR sensor
Accessories whose code ends with "X" are separately supplied.HIDTI52BX- HIDTI52NX: available from April 2016ELFOAir accessories are available in the dedicated page.
48
(MSER-XEE 31-61)GAIA Aria 31-61
TEC
HN
ICA
L D
ATA
31 61
7,30 16,01,62 3,634,51 4,41
6,22 12,51,59 3,323,86 3,67
5,05 11,51,61 3,773,14 3,05
8,20 17,72,16 4,903,80 3,61
6,80 14,91,96 4,533,47 3,30
5,80 11,71,94 4,142,97 2,75
4,91 11,21,93 4,672,54 2,40
5,81 13,51,93 4,643,01 2,925,25 5,22
6,37 14,52,30 5,352,76 2,70
5,44 11,12,31 4,902,35 2,16
4,62 10,82,14 5,802,16 1,86
90 900,36 0,7863 34186 186
2703 3186230/1/50 400/3/50+N
36 3754 52-22 -2260 60
TECHNICAL DATA
Size – MSER-XEEUnit for radiant panels
A7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W18 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Terminal unitsA7/W45
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W7 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -ESEER -
RadiatorsA7/W55
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
Max external static pressure PaWater flow-rate (User Side) (1) l/sUseful pump discharge head (1) kPaDomestic hot water storage lSolar heat exchanger capacity W/KStandard power supply VSound pressure level (1m) indoor unit (2) dB(A)Sound pressure level (1m) outdoor unit (2) dB(A)Min inlet air temperature (W.B.) °CMax. leaving water temperature °C
Notes
Performance levels refer to the energy exchanger located 3m from the interior unit.(1) Data referred to the following conditions: Internal exchanger water = 23/18°C; External
exchanger inlet air 35°C D.B.(2) Sound levels refer to units with full load under nominal test conditions. The sound pressure is
measured at 1 m from the external surface of the unit in open field conditions.
Performances according to EN 14511:2013
A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W35 internal exchanger water 30/35°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W35 internal exchanger water 30/35°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W45 internal exchanger water 40/45°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W45 internal exchanger water 40/45°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W45 internal exchanger water 40/45°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W55 internal exchanger water 45/55°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W55 internal exchanger water 45/55°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W55 internal exchanger water 45/55°C; external air temperature -7°C D.B./ -8°C W.B.
A35/W18 internal exchanger water 23/18°C; external air temperature 35°C
A35/W7 internal exchanger water 12/7°C; external air temperature 35°C
The rated heating and cooling capacities refer to 75% of the maximum compressor revolutions.
Capacity modulation is comprised between 30% and 100%.
Modulation between 75% and 100% only takes place at a outdoor air temperature of below 0°C.
49
ErP
2030
200
600800
800100
300
AB
C
300
800 800
(**)
C
A
B
100
500
800
100
200 MSER-XEE OUT
MSER-XEE
(*)
Two-section integrated thermodynamic air-water reversible heat pump unit
300
AB
C
300
800 800
(**)
C
A
B
100
500
800
100
200
MSER-XEE OUT
MSER-XEE
MSER-XEE OUT 31 61A - Length mm 860 1250B - Width mm 720 790C - Height mm 845 1304Operating wt. kg 58 105
MSER-XEE 31 61A - Length mm 630 630B - Width mm 800 800C - Height mm 2030 2030Operating wt. kg 430 460
Refrigerant R-410A ELFOControl2 Full Inverter DC
AUXILIARY DOMESTIC HOT WATER STORAGEOptional accessory for installations with domestic hot water consumption
Capacity: 280-litres
Optional accessory
CAUTION! Clearances, in green, might be occupied by furniture or other items, but it must be possible to remove them easily for maintenance.(*) Maximum equivalent length of the cooling lines = 25 m, with a max difference level of 15 m(**) Water connections
DIMENSIONS
Default water connections with Gaia
31 61A++ A++A++ A++
A AL L
4,90 5,114,71 4,965,37 5,69
Size – MSER-XEEErP System Energy Class - AVERAGE Climate - W55 (1) -ErP Space Heating Energy Class - AVERAGE Climate - W55 (2) -ErP Domestic Hot Water Energy Class (3) -ErP Domestic Hot Water Profile (4) -Efficiency on specific locations -SCOP Glsagow (5) -SCOP London (5) -SCOP Plymouth (5) -
Notes
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW at specified reference conditions)(1) Seasonal Space Heating Energy Efficiency Class of the package according to Commission
delegated Regulation (EU) No 811/2013(2) Seasonal Space Heating Energy Efficiency Class according to Commission delegated Regulation
(EU) No 811/2013. W = Water outlet temperature (°C)(3) Water Heating Energy Efficiency Class according to Commission delegated Regulation (EU) No
811/2013
(4) Considered Load profile for the definition of Domestic Hot Water Energy Class according to Commission delegated Regulation (EU) No 811/2013. Class of the package with ELFOControl2
(5) SCOP values calculated by similar procedure as indicated in the UNI 14825 using frequency values of hourly occurrence (BIN) of the indicated locations, with flowing water temperature depending on the outdoor air temperature for radiant panels and thermal power to T_design equal to the capacity declared for the European ErP Directive for Climate High Temperature Heat Pumps.
ACCESSORIES
Size – MSER-XEE 31 61Basic configuration (230/1/50) + ELFOControl2 std option
Basic configuration (400/3/50) + ELFOControl2 - std
EH04 Modulating integration electric heater from 0 to 4kwEH246 Modular supplementary electric heater, from 2-4 and 6kWKIRLX Mixed booster hydraulic kit separately supplied (Available only with SRILX)KIRHX Booster hydraulic kit not mixed separately supplied (Available only with SRILX)A280X Auxiliary domestic hot water storageSRILX Additional card for second and third booster managementFDCCX Connection flange with exhaust air duct in the basement
Accessories whose code ends with "X" are separately supplied.Elfocontrol2 control accessories are available in the dedicated page.
50
(WSHR-XEE 31-61)GAIA Acqua 31-61
31 61
8,43 15,71,69 3,065,00 5,11
6,69 12,41,57 2,904,14 4,25
9,29 17,21,80 2,915,17 5,89
7,84 15,62,02 3,843,87 4,05
5,94 11,51,85 3,433,16 3,31
6,76 12,41,73 3,003,91 4,125,73 4,83
6,98 13,42,25 3,943,09 3,33
5,52 9,902,16 3,762,54 2,60
0,40 0,7560 32
0,53 0,9740 98186 186
2703 3186230/1/50 400/3/50+N
36 37-8,0 -8,060 60
Size – WSHR-XEEUnit for radiant panels
W10/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
B0/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
W35/W18 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Terminal unitsW10/W45
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
B0/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
W35/W7 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -ESEER -
RadiatorsW10/W55
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
B0/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
Water flow-rate (User Side) l/sUseful pump discharge head kPaWater flow rate (Source Side) l/sUseful pump discharge head (Source Side) kPaDomestic hot water storage lSolar heat exchanger capacity W/KStandard power supply VSound pressure level (1m) indoor unit dB(A)Min. leaving water temperature °CMax. leaving water temperature °C
Notes
Performances according to EN 14511:2013
W10/W35 water at the user side heat exchanger 30/35°C; inlet water at the source side heat exchanger 10°C
B0/W35 water at the user side heat exchanger 30/35°C; inlet water at the source side heat exchanger 0°C;
glycol 30%
W10/W45 water at the user side heat exchanger 40/45°C; inlet water at the source side heat exchanger 10°C
B0/W45 water at the user side heat exchanger 40/45°C; inlet water at the source side heat exchanger 0°C;
glycol 30%
W10/W55 water at the user side heat exchanger 45/55°C; inlet water at the source side heat exchanger 10°C
B0/W55 water at the user side heat exchanger 45/55°C; inlet water at the source side heat exchanger 0°C;
glycol 30%
W35/W18 water at the user side heat exchanger 23/18°C; inlet water at the source side heat exchanger 30/35°C
W35/W7 water at the user side heat exchanger 12/7°C; inlet water at the source side heat exchanger 30/35°C
The nominal heating and cooling capacities of the GAIA 31 refer to 75% of maximum compressor speed. The
rated heating and cooling capacities of GAIA Acqua 61 refer to 60% of the maximum compressor revolutions.
Capacity modulation is comprised between 30% and 100%. The modulation to 100% only takes place at a
temperature of below 0°C.
The modulation to 100% only takes place at a temperature of below 0°C.
TEC
HN
ICA
L D
ATA
51
ErP
C
(*)
AB
500
500
800
100
200
2030
200
600800
800100
CAUTION! Clearances, in green, might be occupied by furniture or other items, but it must be possible to remove them easily for maintenance
Integrated thermodynamic water-water reversible heat pump unit
WSHR-XEE 31 61A - Length mm 635 635B - Width mm 800 800C - Height mm 2030 2030Operating wt. kg 430 460
ELFOControl2 Full Inverter DC
AUXILIARY DOMESTIC HOT WATER STORAGEOptional accessory for installations with domestic hot water consumption
Capacity: 280-litres
Optional accessory
Refrigerant R-410A
DIMENSIONS
* Water connections
Default water connections with Gaia
31 61A+++ A+++A++
A+++ ErP 2019
A++
A+++ ErP 2019A AL L
5,85 5,865,84 5,855,91 5,92
Size – WSHR-XEEErP System Energy Class - AVERAGE Climate - W55 (1) -ErP Space Heating Energy Class - AVERAGE Climate - W55
(2) -
ErP Domestic Hot Water Energy Class (3) -ErP Domestic Hot Water Profile (4) -Efficiency on specific locations -SCOP Glsagow (5) -SCOP London (5) -SCOP Plymouth (5) -
Notes
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW
at specified reference conditions)(1) Seasonal Space Heating Energy Efficiency Class of the package according to Commission
delegated Regulation (EU) No 811/2013(2) Seasonal Space Heating Energy Efficiency Class according to Commission delegated Regulation
(EU) No 811/2013. W = Water outlet temperature (°C)(3) Water Heating Energy Efficiency Class according to Commission delegated Regulation (EU) No
811/2013
(4) Considered Load profile for the definition of Domestic Hot Water Energy Class according to Commission delegated Regulation (EU) No 811/2013. Class of the package with ELFOControl2
(5) SCOP values calculated by similar procedure as indicated in the UNI 14825 using frequency values of hourly occurrence (BIN) of the indicated locations, with flowing water temperature depending on the outdoor air temperature for radiant panels and thermal power to T_design equal to the capacity declared for the European ErP Directive for Climate High Temperature Heat Pumps.
ACCESSORIES
Size – WSHR-XEE 31 61Basic configuration (230/1/50) + ELFOControl2 std option
Basic configuration (400/3/50) + ELFOControl2 - std
NC NaturalcoolingEH246 Modular supplementary electric heater, from 2-4 and 6kWEH04 Modulating integration electric heater from 0 to 4kwKIRLX Mixed booster hydraulic kit separately supplied (Available only with SRILX)KIRHX Booster hydraulic kit not mixed separately supplied (Available only with SRILX)- Hydronic assembly source side: not requiredA280X Auxiliary domestic hot water storageIVMS Modulating valve source sideSRILX Additional card for second and third booster management
Accessories whose code ends with "X" are separately supplied.Elfocontrol2 control accessories are available in the dedicated page.
* Water connections
52
GAIA L Comfort(GLC A÷B + MSAN-GL)
2.1 3.1 4.1 5.1 7.1 8.1
5,19 6,87 8,54 12,2 14,3 17,01,32 1,76 2,18 3,12 3,66 4,353,94 3,91 3,91 3,91 3,91 3,91
4,06 5,40 6,70 9,59 11,2 13,51,29 1,71 2,13 3,07 3,58 4,263,14 3,16 3,15 3,12 3,14 3,18
3,30 4,47 5,44 7,86 9,14 11,21,22 1,64 2,00 2,90 3,36 4,132,70 2,71 2,72 2,71 2,72 2,71
4,11 6,56 8,05 10,7 12,2 15,91,07 1,78 2,23 2,77 3,38 4,383,85 3,69 3,61 3,86 3,61 3,64
5,01 6,59 8,65 11,6 13,6 16,61,59 2,11 2,89 3,77 4,50 5,503,15 3,12 2,99 3,08 3,02 3,02
3,93 5,18 6,85 9,28 10,6 13,11,55 2,04 2,78 3,67 4,30 5,292,54 2,54 2,47 2,53 2,47 2,49
3,00 3,90 5,30 7,28 8,65 10,61,47 1,89 2,59 3,64 4,13 5,172,04 2,06 2,04 2,00 2,09 2,05
4,05 5,37 7,19 8,65 11,1 15,51,46 1,93 2,79 3,12 4,51 5,952,77 2,78 2,58 2,77 2,46 2,624,08 4,02 3,89 4,03 4,00 4,06
4,72 6,30 8,00 10,6 12,5 15,31,96 2,59 3,54 4,65 5,74 6,952,41 2,44 2,26 2,29 2,17 2,20
3,72 4,92 6,30 8,48 10,0 12,11,90 2,48 3,39 4,58 5,65 6,691,96 1,99 1,86 1,85 1,77 1,80
2,84 3,76 4,91 6,65 8,59 9,901.74 2,27 3,10 4,49 5,50 6,601,63 1,65 1,58 1,48 1,56 1,50
0,25 0,33 0,41 0,58 0,68 0,8151 50 47 53 47 37
280 280 280 280 280 2802703 2703 2703 3186 3186 3186
230/1/50 230/1/50 230/1/50 400/3/50+N 400/3/50+N 400/3/50+N49 49 49 53 54 56-20 -20 -20 -20 -20 -2060 60 60 60 60 60
Size – GLC+MSAN-GLUnit for radiant panels
A7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W18 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Terminal unitsA7/W45
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W7 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -ESEER -
RadiatorsA7/W55
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
Water flow-rate (User Side) (1) l/sUseful pump discharge head kPaDomestic hot water storage lSolar heat exchanger capacity W/KStandard power supply VSound pressure level (1m) outdoor unit dB(A)Min inlet air temperature (W.B.) °CMax. leaving water temperature °C
Notes
TEC
HN
ICA
L D
ATA
TECHNICAL DATA
(1) A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
Performances according to EN 14511:2013
A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W35 internal exchanger water 30/35°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W35 internal exchanger water 30/35°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W45 internal exchanger water 40/45°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W45 internal exchanger water 40/45°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W45 internal exchanger water 40/45°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W55 internal exchanger water 50/55°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W55 internal exchanger water 50/55°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W55 internal exchanger water 50/55°C; external air temperature -7°C D.B./ -8°C W.B.
A35/W18 internal exchanger water 23/18°C; external air temperature 35°C
A35/W7 internal exchanger water 12/7°C; external air temperature 35°C
53
ErP
(*)
(**)
C
A
B
30
100
800
10
200
A1
C
600
B2A
B
MSAN-GL
GLC
2030
200
600800
800100
ATTENTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.
(*)Maximum equivalent length of the cooling lines = 25 m, with a max difference level of 15 m (**) Unit hydraulic and gas connections
Two-section air-water reversible heat pump
Size – GLC A BA - Length mm 600 600B - Width mm 800 800C - Height mm 2040 2040Operating weight kg 450 470
Size – MSAN-GL 2.1 3.1 4.1 5.1 7.1 8.1 A - Length mm 942 942 942 1087 1087 1738B - Width mm 450 450 450 460 460 720C - Height mm 988 988 988 1234 1234 1137A1 mm 250 250 250 300 300 350B2 mm 200 200 200 250 250 350Operating weight kg 102 105 113 157 161 225
ELFOControl2 Full Inverter DCRefrigerant R-410A
DIMENSIONS
AUXILIARY DOMESTIC HOT WATER STORAGEOptional accessory for installations with domestic hot water consumption
Capacity: 280-litres
Optional accessory
Default water connections with Gaia
2.1 3.1 4.1 5.1 7.1 8.1 A++ A++ A++ A++ A++ A++A++ A++ A++ A++ A++ A++
A A A A A AXL XL XL XL XL XL
4,62 4,45 4,67 4,34 4,36 4,284,42 4,29 4,57 4,26 4,28 4,215,01 4,81 5,23 4,64 4,67 4,58
Size – GLC+MSAN-GLErP System Energy Class - AVERAGE Climate - W55 (1) -ErP Space Heating Energy Class - AVERAGE Climate - W55 (2) -ErP Domestic Hot Water Energy Class (3) -ErP Domestic Hot Water Profile (4) -Efficiency on specific locations -SCOP Glsagow (5) -SCOP London (5) -SCOP Plymouth (5) -
Notes
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW
at specified reference conditions)(1) Seasonal Space Heating Energy Efficiency Class of the package according to Commission
delegated Regulation (EU) No 811/2013(2) Seasonal Space Heating Energy Efficiency Class according to Commission delegated Regulation
(EU) No 811/2013. W = Water outlet temperature (°C)(3) Water Heating Energy Efficiency Class according to Commission delegated Regulation (EU) No
811/2013
(4) Considered Load profile for the definition of Domestic Hot Water Energy Class according to Commission delegated Regulation (EU) No 811/2013. Class of the package with ELFOControl2
(5) SCOP values calculated by similar procedure as indicated in the UNI 14825 using frequency values of hourly occurrence (BIN) of the indicated locations, with flowing water temperature depending on the outdoor air temperature for radiant panels and thermal power to T_design equal to the capacity declared for the European ErP Directive for Climate High Temperature Heat Pumps.
ACCESSORIES
Size – GLC+MSAN-GL 2.1 3.1 4.1 5.1 7.1 8.1 Basic configuration (230/1/50) std std std option option -
Basic configuration (400/3/50) - - - std std std
EH246X 2-4 and 6 kW integration electric heaterGLS GAIA L Comfort SolarA280X Auxiliary domestic hot water storageKCCEX External boiler connection kitHIDTi52BX Temperature and humidity thermostat / Remote keyboard with touch display for recessed (box 503) or wall mounting. White
HIDTi52NX Temperature and humidity thermostat / Remote keyboard with touch display for recessed (box 503) or wall mounting. Black
AMRX Rubber antivibration mountsAL12X Power supply unit for HID-Ti5 thermostats and HID-UR sensor
Accessories whose code ends with "X" are separately supplied.
HIDTI52BX- HIDTI52NX: available from April 2016
54
GAIA L Hybrid(GLH A÷B + MSAN-GL)
2.1 3.1 4.1 5.1 7.1 8.1
5,19 6,87 8,54 12,2 14,3 17,01,32 1,76 2,18 3,12 3,66 4,353,94 3,91 3,91 3,91 3,91 3,91
4,06 5,40 6,70 9,59 11,2 13,51,29 1,71 2,13 3,07 3,58 4,263,14 3,16 3,15 3,12 3,14 3,18
3,30 4,47 5,44 7,86 9,14 11,21,22 1,64 2,00 2,90 3,36 4,132,70 2,71 2,72 2,71 2,72 2,71
4,11 6,56 8,05 10,7 12,2 15,91,07 1,78 2,23 2,77 3,38 4,383,85 3,69 3,61 3,86 3,61 3,64
5,01 6,59 8,65 11,6 13,6 16,61,59 2,11 2,89 3,77 4,50 5,503,15 3,12 2,99 3,08 3,02 3,02
3,93 5,18 6,85 9,28 10,6 13,11,55 2,04 2,78 3,67 4,30 5,292,54 2,54 2,47 2,53 2,47 2,49
3,00 3,90 5,30 7,28 8,65 10,61,47 1,89 2,59 3,64 4,13 5,172,04 2,06 2,04 2,00 2,09 2,05
4,05 5,37 7,19 8,65 11,1 15,51,46 1,93 2,79 3,12 4,51 5,952,77 2,78 2,58 2,77 2,46 2,624,08 4,02 3,89 4,03 4,00 4,06
4,72 6,30 8,00 10,6 12,5 15,31,96 2,59 3,54 4,65 5,74 6,952,41 2,44 2,26 2,29 2,17 2,20
3,72 4,92 6,30 8,48 10,0 12,11,90 2,48 3,39 4,58 5,65 6,691,96 1,99 1,86 1,85 1,77 1,80
2,84 3,76 4,91 6,65 8,59 9,901.74 2,27 3,10 4,49 5,50 6,601,63 1,65 1,58 1,48 1,56 1,50
G20-G30-G3124 24 24 24 24 24
2,90,25 0,33 0,41 0,58 0,68 0,8141 33 32 53 47 37
280 280 280 280 280 2802703 2703 2703 3186 3186 3186
230/1/50 230/1/50 230/1/50 400/3/50+N 400/3/50+N 400/3/50+N49 49 49 53 54 56-20 -20 -20 -20 -20 -2060 60 60 60 60 60
Size – GLH+MSAN-GLUnit for radiant panels
A7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W18 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Terminal unitsA7/W45
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W7 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -ESEER -
RadiatorsA7/W55
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
Type of gas (1) -Nominal heat flow-rate kWMinimal heat flow-rate kWWater flow-rate (User Side) (2) l/sUseful pump discharge head kPaDomestic hot water storage lSolar heat exchanger capacity W/KStandard power supply VSound pressure level (1m) outdoor unit dB(A)Min inlet air temperature (W.B.) °CMax. leaving water temperature °C
Notes
TEC
HN
ICA
L D
ATA
TECHNICAL DATA
(1) G20: Methane gas 100%, standard; G30 / G31: LPG gas, a separate accessory is supplied for converting the boiler to LPG
(2) A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
Performances according to EN 14511:2013
A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W35 internal exchanger water 30/35°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W35 internal exchanger water 30/35°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W45 internal exchanger water 40/45°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W45 internal exchanger water 40/45°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W45 internal exchanger water 40/45°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W55 internal exchanger water 50/55°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W55 internal exchanger water 50/55°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W55 internal exchanger water 50/55°C; external air temperature -7°C D.B./ -8°C W.B.
A35/W18 internal exchanger water 23/18°C; external air temperature 35°C
A35/W7 internal exchanger water 12/7°C; external air temperature 35°C
55
ErP
GLH
2030
200
600800
800100
Two-section air-water reversible heat pump with integration boiler
ELFOControl2 Full Inverter DCRefrigerant R-410A
DIMENSIONS
AUXILIARY DOMESTIC HOT WATER STORAGEOptional accessory for installations with domestic hot water consumption
Capacity: 280-litres
Optional accessory
Default water connections with Gaia
2.1 3.1 4.1 5.1 7.1 8.1 A++ A++ A++ A++ A++ A++A++ A++ A++ A++ A++ A++
A A A A A AXL XL XL XL XL XL
4,62 4,45 4,45 4,34 4,36 4,284,42 4,29 4,33 4,26 4,28 4,215,01 4,81 4,91 4,64 4,67 4,58
ACCESSORIES
Size – GLH+MSAN-GL 2.1 3.1 4.1 5.1 7.1 8.1 Basic configuration (230/1/50) std std std option option -
Basic configuration (400/3/50) - - - std std std
GLHS GAIA L Hybrid SolarA280X Auxiliary domestic hot water storageKTCGPLX Conversion kit boiler from methane to LPGHIDTi52BX Temperature and humidity thermostat / Remote keyboard with touch display for recessed (box 503) or wall mounting. White
HIDTi52NX Temperature and humidity thermostat / Remote keyboard with touch display for recessed (box 503) or wall mounting. Black
AMRX Rubber antivibration mountsAL12X Power supply unit for HID-Ti5 thermostats and HID-UR sensor
Accessories whose code ends with "X" are separately supplied.
HIDTI52BX- HIDTI52NX: available from April 2016
Size – GLH+MSAN-GLErP System Energy Class - AVERAGE Climate - W55 (1) -ErP Space Heating Energy Class - AVERAGE Climate - W55 (2) -ErP Domestic Hot Water Energy Class (3) -ErP Domestic Hot Water Profile (4) -Efficiency on specific locations -SCOP Glsagow (5) -SCOP London (5) -SCOP Plymouth (5) -
Notes
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW
at specified reference conditions)(1) Seasonal Space Heating Energy Efficiency Class of the package according to Commission
delegated Regulation (EU) No 811/2013(2) Seasonal Space Heating Energy Efficiency Class according to Commission delegated Regulation
(EU) No 811/2013. W = Water outlet temperature (°C)(3) Water Heating Energy Efficiency Class according to Commission delegated Regulation (EU) No
811/2013
(4) Considered Load profile for the definition of Domestic Hot Water Energy Class according to Commission delegated Regulation (EU) No 811/2013. Class of the package with ELFOControl2
(5) SCOP values calculated by similar procedure as indicated in the UNI 14825 using frequency values of hourly occurrence (BIN) of the indicated locations, with flowing water temperature depending on the outdoor air temperature for radiant panels and thermal power to T_design equal to the capacity declared for the European ErP Directive for Climate High Temperature Heat Pumps.
ATTENTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.
(*)Maximum equivalent length of the cooling lines = 25 m, with a max difference level of 15 m (**) Unit hydraulic and gas connections
Size – GLH A BA - Length mm 600 600B - Width mm 800 800C - Height mm 2040 2040Operating weight kg 480 500
Size – MSAN-GL 2.1 3.1 4.1 5.1 7.1 8.1 A - Length mm 942 942 942 1087 1087 1738B - Width mm 450 450 450 460 460 720C - Height mm 988 988 988 1234 1234 1137A1 mm 250 250 250 300 300 350B2 mm 200 200 200 250 250 350Operating weight kg 102 105 113 157 161 225
(*)
(**)
C
A
B
30
100
800
10
300
A1
C
600
B2
A
B
MSAN-GL
56
(MSER-XIN 61)GAIA MAXI Hybrid Aria
TEC
HN
ICA
L D
ATA
61
16,03,634,41
12,53,323,67
11,53,773,05
18,04,933,65
14,94,533,30
11,74,142,75
11,24,672,40
13,54,642,925,22
14,55,352,70
11,14,902,16
10,805,801,86
G20-G30-G31242,9
0,78281802803186
400/3/50+N903752-2218
Size – MSER-XINUnit for radiant panels
A7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W18 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Terminal unitsA7/W45
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W7 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -ESEER -
RadiatorsA7/W55
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
Type of gas (1) -Nominal heat flow-rate kWMinimal heat flow-rate kWWater flow rate (Internal Exchanger) l/sSTD booster available pressure kPaSystem storage lDomestic hot water storage lSolar heat exchanger capacity W/KStandard power supply VMax static pressure fan PaSound pressure level (1m) indoor unit dB(A)Sound pressure level (1m) outdoor unit dB(A)Min inlet air temperature (W.B.) °CMax. leaving water temperature °C
Notes
(1) G20: Methane gas 100%, standard; G30 / G31: LPG gas, a separate accessory is supplied for converting the boiler to LPG
Performances according to EN 14511:2013
A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.A2/W35 internal exchanger water 30/35°C; external air temperature 2°C D.B./ 1,1°C W.B.A-7/W35 internal exchanger water 30/35°C; external air temperature -7°C D.B./ -8°C W.B.A7/W45 internal exchanger water 40/45°C; external air temperature 7°C D.B./ 6°C W.B.A2/W45 internal exchanger water 40/45°C; external air temperature 2°C D.B./ 1,1°C W.B.A-7/W45 internal exchanger water 40/45°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W55 internal exchanger water 45/55°C; external air temperature 7°C D.B./ 6°C W.B.A2/W55 internal exchanger water 45/55°C; external air temperature 2°C D.B./ 1,1°C W.B.A-7/W55 internal exchanger water 45/55°C; external air temperature -7°C D.B./ -8°C W.B.A35/W18 internal exchanger water 23/18°C; external air temperature 35°CA35/W7 internal exchanger water 12/7°C; external air temperature 35°CThe rated heating and cooling capacities refer to 75% of the maximum compressor revolutions. Capacity modulation is comprised between 30% and 100%.Modulation between 75% and 100% only takes place at a outdoor air temperature of below 0°C.
TECHNICAL DATA
57
ErP
100B
800500
A
100
300AB
C
300
800 800
(**)
(*)
C
300
Combined energy thermodynamic air-water unit
Full Inverter DCELFOControl2
Size - GAIA Maxi A - Length mm 1150B - Width mm 800C - Height mm 2040Operating weight kg 1000
Size - Energy exchanger A - Length mm 1250B - Width mm 790C - Height mm 1304Operating weight kg 105
Refrigerant R-410A
CAUTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.(*)Maximum equivalent length of the cooling lines = 25 m, with a max difference level of 15 m(**) Unit hydraulic and gas connections
DIMENSIONS
Energy exchangerIt adapts to many positioning solutions external or internal, with or without ducting.
61A++A++
AXL
5,084,915,68
ACCESSORIES
Size – MSER-XIN 61Basic configuration (230/1/50) + ELFOControl2 optional
Basic configuration (400/3/50) + ELFOControl2 std
KIRS Base hydraulic kit 1 standard areaKIR1SAP Base hydraulic kit 1 high static pressure areaKIR2H 2 zones: both at high temperatureKIR2HL 2 zones: high temperature + low temperature (mixed)KIR3H 3 zones: all at high temperatureKIR3HHL 3 zones: two at high temperature + one at low temperature (mixed)KIR3HLL 3 zones: one at high temperature + two at low temperature (mixed)KIR4H 4 areas: all at high temperaturesKIR4HHHL 4 areas: three at high temperature + one at low temperature (mixed)KIR4HHLL 4 areas: two at high temperature + two at low temperature (mixed)KIR4HLLL 4 areas: one at high temperature + three at low temperature (mixed)KIRHX Booster hydraulic kit not mixed separately suppliedKIRLX Mixed booster hydraulic kit separately suppliedSOL Drain-back solar integration for domestic hot waterSRILX Additional card for booster management KPSEPX Paneling kit for separate installation of the system module and DHW moduleFDCCX Connection flange with exhaust air duct in the basementKTCGPLX Conversion kit boiler from methane to LPG
Accessories whose code ends with "X" are separately supplied.Elfocontrol2 control accessories are available in the dedicated page.
Size – MSER-XINErP System Energy Class - AVERAGE Climate - W55 (1) -ErP Space Heating Energy Class - AVERAGE Climate - W55 (2) -ErP Domestic Hot Water Energy Class (3) -ErP Domestic Hot Water Profile (4) -Efficiency on specific locations -SCOP Glsagow (5) -SCOP London (5) -SCOP Plymouth (5) -
Notes
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW
at specified reference conditions)(1) Seasonal Space Heating Energy Efficiency Class of the package according to Commission
delegated Regulation (EU) No 811/2013(2) Seasonal Space Heating Energy Efficiency Class according to Commission delegated Regulation
(EU) No 811/2013. W = Water outlet temperature (°C)
(3) Water Heating Energy Efficiency Class according to Commission delegated Regulation (EU) No 811/2013
(4) Considered Load profile for the definition of Domestic Hot Water Energy Class according to Commission delegated Regulation (EU) No 811/2013. Class of the package with ELFOControl2
(5) SCOP values calculated by similar procedure as indicated in the UNI 14825 using frequency values of hourly occurrence (BIN) of the indicated locations, with flowing water temperature depending on the outdoor air temperature for radiant panels and thermal power to T_design equal to the capacity declared for the European ErP Directive for Climate High Temperature Heat Pumps.
58
(WSHR-XIN 61)GAIA MAXI Hybrid Acqua
TEC
HN
ICA
L D
ATA
61
15,73,065,11
12,42,904,25
17,22,915,89
15,63,844,05
11,53,433,31
12,43,004,124,83
13,43,943,33
9,903,762,60
G20-G30-G31242,9
0,7533
0,97981802803186
400/3/50+N37
-8,060
Size – WSHR-XINUnit for radiant panels
W10/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
B0/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
W35/W18 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Terminal unitsW10/W45
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
B0/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
W35/W7 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -ESEER -
RadiatorsW10/W55
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
B0/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
Type of gas (1) -Nominal heat flow-rate kWMinimal heat flow-rate kWWater flow-rate (User Side) (2) l/sUseful pump discharge head (2) kPaWater flow rate (Source Side) (2) l/sUseful pump discharge head (Source Side) kPaSystem Storage lDomestic hot water storage lSolar heat exchanger capacity W/KStandard power supply VSound pressure level (1 m) dB(A)Min. leaving water temperature °CMax. leaving water temperature °C
Notes
(1) G20: Methane gas 100%, standard; G30 / G31: LPG gas, a separate accessory is supplied for converting the boiler to LPG
(2) The values shown, are referred to performances in heating
Performances according to EN 14511:2013
W10/W35 water at the user side heat exchanger 30/35°C; inlet water at the source side heat exchanger 10°C
B0/W35 water at the user side heat exchanger 30/35°C; inlet water at the source side heat exchanger 0°C;
glycol 30%
W10/W45 water at the user side heat exchanger 40/45°C; inlet water at the source side heat exchanger 10°C
B0/W45 water at the user side heat exchanger 40/45°C; inlet water at the source side heat exchanger 0°C;
glycol 30%
W10/W55 water at the user side heat exchanger 45/55°C; inlet water at the source side heat exchanger 10°C
B0/W55 water at the user side heat exchanger 45/55°C; inlet water at the source side heat exchanger 0°C;
glycol 30%
W35/W18 water at the user side heat exchanger 23/18°C; inlet water at the source side heat exchanger 30/35°C
W35/W7 water at the user side heat exchanger 12/7°C; inlet water at the source side heat exchanger 30/35°C
The rated heating and cooling capacities refer to 60% of the maximum compressor revolutions. Capacity
modulation is comprised between 30% and 100%. The modulation to 100% only takes place at a temperature
of below 0°C.
TECHNICAL DATA
59
ErP
100B
800500
A
C
100
(**)
300
CAUTION! Clearances, in green, might be occupied by furniture or other items, but it must be possible to remove them easily for maintenance
Combined energy thermodynamic water-water unit
Full Inverter DCELFOControl2
Size - GAIA Maxi A - Length mm 1150B - Width mm 800C - Height mm 2040Operating weight kg 1000
The above mentioned data are referred to standard units.
Refrigerant R-410A
DIMENSIONS
**Unit hydraulic and gas connections
61A+++A++
A+++ ERP 2019AXL
5,865,855,92
ACCESSORIES
Size – WSHR-XIN 61Basic configuration (230/1/50) + ELFOControl2 optionalBasic configuration (400/3/50) + ELFOControl2 std
HYGS Hydronic assembly source side- Hydronic assembly source side: not requiredIVMS Modulating valve source sideKIRS Base hydraulic kit 1 standard areaKIR1SAP Base hydraulic kit 1 high static pressure areaKIR2H 2 zones: both at high temperatureKIR2HL 2 zones: high temperature + low temperature (mixed)KIR3H 3 zones: all at high temperatureKIR3HHL 3 zones: two at high temperature + one at low temperature (mixed)KIR3HLL 3 zones: one at high temperature + two at low temperature (mixed)KIR4H 4 areas: all at high temperaturesKIR4HHHL 4 areas: three at high temperature + one at low temperature (mixed)KIR4HHLL 4 areas: two at high temperature + two at low temperature (mixed)KIR4HLLL 4 areas: one at high temperature + three at low temperature (mixed)KIRHX Booster hydraulic kit not mixed separately suppliedKIRLX Mixed booster hydraulic kit separately suppliedSOL Drain-back solar integration for domestic hot waterSRILX Additional card for booster management KPSEPX Paneling kit for separate installation of the system module and DHW moduleKTCGPLX Conversion kit boiler from methane to LPG
Accessories whose code ends with "X" are separately supplied.Elfocontrol2 control accessories are available in the dedicated page.
Size – WSHR-XINErP System Energy Class - AVERAGE Climate - W55 (1) -ErP Space Heating Energy Class - AVERAGE Climate - W55
(2) -
ErP Domestic Hot Water Energy Class (3) -ErP Domestic Hot Water Profile (4) -Efficiency on specific locations -SCOP Glsagow (5) -SCOP London (5) -SCOP Plymouth (5) -
Notes
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW
at specified reference conditions)(1) Seasonal Space Heating Energy Efficiency Class of the package according to Commission
delegated Regulation (EU) No 811/2013(2) Seasonal Space Heating Energy Efficiency Class according to Commission delegated Regulation
(EU) No 811/2013. W = Water outlet temperature (°C)
(3) Water Heating Energy Efficiency Class according to Commission delegated Regulation (EU) No 811/2013
(4) Considered Load profile for the definition of Domestic Hot Water Energy Class according to Commission delegated Regulation (EU) No 811/2013. Class of the package with ELFOControl2
(5) SCOP values calculated by similar procedure as indicated in the UNI 14825 using frequency values of hourly occurrence (BIN) of the indicated locations, with flowing water temperature depending on the outdoor air temperature for radiant panels and thermal power to T_design equal to the capacity declared for the European ErP Directive for Climate High Temperature Heat Pumps.
60
GAIA-i (GIGA + MSAN-GL
TEC
HN
ICA
L D
ATA
2.1 3.1 4.1
5,20 6,86 8,531,30 1,75 2,184,01 3,92 3,91
4,07 5,40 6,711,27 1,71 2,153,20 3,16 3,12
3,29 4,65 5,641,22 1,72 2,082,71 2,71 2,71
4,10 5,66 6,471,05 1,43 1,723,90 3,95 3,76
5,01 6,58 8,591,57 2,11 2,833,19 3,12 3,04
3,94 5,19 6,821,53 2,04 2,742,58 2,54 2,49
3,23 4,36 5,801,44 1,91 2,562,24 2,28 2,27
3,86 5,16 6,781,44 1,92 2,732,68 2,69 2,484,09 4,08 3,83
4,74 6,31 7,971,93 2,54 3,492,46 2,48 2,28
3,74 4,94 6,301,86 2,44 3,362,01 2,02 1,88
3,13 4,30 5,391,71 2,24 3,091,83 1,92 1,74
G20-G30-G31242,9
0,25 0,33 0,4136 31 36150 150 150
230/1/50 230/1/50 230/1/5049 49 49-20 -20 -2060 60 60
Size – GIGAUnit for radiant panels
A7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W35 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W18 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Terminal unitsA7/W45
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W45 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A35/W7 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -ESEER -
RadiatorsA7/W55
Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A2/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-7/W55 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
Type of gas (1) -Nominal heat flow-rate kWMinimal heat flow-rate kWWater flow-rate (User Side) (2) l/sUseful pump discharge head (2) kPaDomestic hot water storage lStandard power supply VSound pressure level (1m) outdoor unit dB(A)Min inlet air temperature (W.B.) °CMax. leaving water temperature °C
Notes
(1) G20: Methane gas 100%, standard; G30 / G31: LPG gas, a separate accessory is supplied for converting the boiler to LPG
(2) A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
Performances according to EN 14511:2013
A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W35 internal exchanger water 30/35°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W35 internal exchanger water 30/35°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W45 internal exchanger water 40/45°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W45 internal exchanger water 40/45°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W45 internal exchanger water 40/45°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W55 internal exchanger water 50/55°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W55 internal exchanger water 50/55°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W55 internal exchanger water 50/55°C; external air temperature -7°C D.B./ -8°C W.B.
A35/W18 internal exchanger water 23/18°C; external air temperature 35°C
A35/W7 internal exchanger water 12/7°C; external air temperature 35°C
TECHNICAL DATA
61
ErP
Two-section air-water reversible heat pump with integration boiler
ELFOControl2 Full Inverter DCRefrigerant R-410A
DIMENSIONS
2.1 3.1 4.1A++ A++ A++A++ A++ A++
A A AL L L
4,15 4,34 4,694,05 4,23 4,524,48 4,75 5,04
ACCESSORIES
Size – GIGA+MSAN-GLErP System Energy Class - AVERAGE Climate - W55 (1) -ErP Space Heating Energy Class - AVERAGE Climate - W55 (2) -ErP Domestic Hot Water Energy Class (3) -ErP Domestic Hot Water Profile (4) -Efficiency on specific locations -SCOP Glsagow (5) -SCOP London (5) -SCOP Plymouth (5) -
Notes
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW
at specified reference conditions)(1) Seasonal Space Heating Energy Efficiency Class of the package according to Commission
delegated Regulation (EU) No 811/2013(2) Seasonal Space Heating Energy Efficiency Class according to Commission delegated Regulation
(EU) No 811/2013. W = Water outlet temperature (°C)
(3) Water Heating Energy Efficiency Class according to Commission delegated Regulation (EU) No 811/2013
(4) Considered Load profile for the definition of Domestic Hot Water Energy Class according to Commission delegated Regulation (EU) No 811/2013. Class of the package with ELFOControl2
(5) SCOP values calculated by similar procedure as indicated in the UNI 14825 using frequency values of hourly occurrence (BIN) of the indicated locations, with flowing water temperature depending on the outdoor air temperature for radiant panels and thermal power to T_design equal to the capacity declared for the European ErP Directive for Climate High Temperature Heat Pumps.
SIZE – GIGA+MSAN-GL 2.1 3.1 4.1Basic configuration (230/1/50) std std std
ADIX Recessed storage unit with jigs for fittingsACS150X 150-litre domestic hot water storage tankEH04X Modular supplementary electric heater, from 2-4kWCCGIX Integration condensing boiler 3-24 kWKDSRX Hydraulic breaker with board to boosters managmentKIRHX Booster hydraulic kit not mixed separately suppliedKIRLX Mixed booster hydraulic kit separately suppliedHIDTi52BX Temperature and humidity thermostat / Remote keyboard with touch display for recessed (box 503) or wall mounting. White
HIDTi52NX Temperature and humidity thermostat / Remote keyboard with touch display for recessed (box 503) or wall mounting. Black
AMRX Rubber antivibration mountsKSOLX Solar thermal kitKTCGPLX Conversion kit boiler from methane to LPGAL12X Power supply unit for HID-Ti5 thermostats and HID-UR sensor
Accessories whose code ends with "X" are separately supplied.
HIDTI52BX- HIDTI52NX - KSOLX: available from April 2016
ATTENTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.(*)Maximum equivalent length of the cooling lines = 25 m, with a max difference level of 15 m(**) Water connections
Size – GIGA AA - Length mm 950B - Width mm 350C - Height mm 2200B1 mm 500Operating weight kg 290
Size – MSAN-GL 2.1 3.1 4.1A - Length mm 942 942 942B - Width mm 450 450 450C - Height mm 988 988 988A1 mm 250 250 250B2 mm 200 200 200Operating weight kg 102 105 113
62
(CPAN-U 70-650)ELFOFresh2
B1
B
B2 A1120
A
A2
C
C1
TEC
HN
ICA
L D
ATA
CAUTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.
* for sizes 200-650 data include the electrical panel installed on the unit as standard.
CPAN-U 70-120with air fl ow rate from 70 to 120 m³/h
CPAN-U 200-650with air fl ow rate from 200 to 650 m³/h
Size 70 120 200 300 500 650A - Length mm 800 800 922 922 1158 1158B - Width mm 690 690 704 704 741 741C - Height mm 266 266 364 364 423 423A1 mm 20 20 620 620 620 620A2 mm 500 500 20 20 20 20B1 mm 300 300 300 300 300 300B2 mm 300 300 300 300 300 300C1 mm 15 15 20 20 20 20Operating w. kg 40 43 70 75 95 100
The above mentioned data are referred to standard units.
TECHNICAL DATA
DIMENSIONS
Exhaust
Extraction
Fresh air supply
Fresh air
70 120
0,52 0,980,15 0,253,38 3,90
0,52 0,970,12 0,204,17 4,74
0,43 0,810,19 0,322,27 2,58
0,45 0,850,20 0,332,24 2,5419,4 33,3120 120
230/1/50 230/1/50-15 -1537 38
200 300 500 650
1,81 2,33 3,58 5,000,44 0,59 0,84 1,274,11 3,95 4,26 3,94
1,86 2,35 3,74 5,100,36 0,43 0,67 1,005,17 5,47 5,58 5,10
1,57 2,10 3,01 4,030,54 0,70 1,04 1,482,91 3,00 2,89 2,72
1,63 2,17 3,13 4,230,57 0,73 1,10 1,602,86 2,97 2,85 2,6455,0 83,0 139 181120 120 120 120
230/1/50 230/1/50 230/1/50 230/1/50-15 -15 -15 -1539 41 44 46
Size – CPAN-U
A7 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-5 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A30 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
A35 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Supply airflow l/sMax. static pressure supply fan PaStandard power supply VMin. entering air temperature (D.B.) (2) °CSound pressure level (1) dB(A)
Size – CPAN-U
A7 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A-5 Heating capacity kWTotal power input kWCOP (EN 14511:2013) -
A30 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
A35 Cooling capacity kWTotal power input kWEER (EN 14511:2013) -
Supply airflow l/sMax. static pressure supply fan PaStandard power supply VMin. entering air temperature (D.B.) (2) °CSound pressure level (1) dB(A)
Notes
(1) The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of 1m from the external surface of the units
operating in an open field.(2) In places where temperatures drop under -5°C for a considerable number of hours a year, it is
recommended to use EHPCX - electric duct heaters kit.
All the data provided meets standard EN 14511:2013 and refers to an available head of 50 Pa. When in
cooling mode it is possible that the unit is operating at a reduced flow to ensure a specific humidity
for the air introduced into the environment in keeping with the setpoint.
A7 External air temperature 7°C D.B./ 6°C W.B., Exhaust air temperature 20°C D.B./ 15°C W.B.
A-5 External air temperature -5°C D.B./ -5.4°C W.B., Exhaust air temperature 20°C D.B./ 15°C W.B.
A30 External air temperature 30°C D.B./ 22°C W.B., Exhaust air temperature 27°C D.B./ 19°C W.B.
A35 External air temperature 35°C D.B./ 24°C W.B., Exhaust air temperature 27°C D.B./ 19°C W.B.
63
Air renewal unit with thermodynamic heat recovery
Refrig. R-134A size 70÷120
Refrig. R-410A size 200÷650
ELFOControl2Indoor installation
ACCESSORIES
ELFOFRESH2 200 OPERATING CRITERIA AND PERFORMANCE
DC Motor
Size – CPAN-U 70 120 200 300 500 650Basic configuration (230/1/50) std std std std std std
Base price includes thermostat Te/RH
OHO Heating-only operationFESX Electronic filter kitHSE3MX Immersed electrode steam humidifier for ELFOFresh DN250HSE3LX Immersed electrode steam humidifier for ELFOFresh DN200FAEX Kit of exhaust air filterCDPX Condensate drain pumpCMMBX Serial communication module to supervisor (Modbus)EHPCX Preheating elements in duct
Accessories whose code ends with "X" are separately supplied.ELFOAir accessories are available in the dedicated page.
A Coeffi cient of performance in
heating mode (COP) and in
cooling mode (EER): it is the ratio
between the power delivered
and the power input of the
compressor, auxiliary circuit and
fans, in consideration of an ESP of
50 Pa
B Required ambient temperature
C ELFOFresh² delivery air
temperature in the room (°C)
THE CHART SHOWS
THE FOLLOWING VARIABLES:
Note: performance curves of the
other sizes are available in the
technical bulletin
D Heating / cooling performance
(W)
E Power input
(W)
F Internal relative humidity
(g/kg)
G External relative humidity
(g/kg)
H Supply relative humidity
(g/kg)
I Supply airfl ow
(mch)
THE CHART SHOWS
THE FOLLOWING
VARIABLES:
64
ELFORoom2
003.0 005.0 011.0 015.0 017.00,89 1,91 2,83 3,69 4,190,65 1,29 1,94 2,50 2,780,012 0,020 0,022 0,030 0,0330,93 1,97 2,71 3,45 4,1145,0 89,0 128 160 180TGZ TGZ TGZ TGZ TGZ
230/1/50 230/1/50 230/1/50 230/1/50 230/1/5023 26 27 23 2732 32 33 30 3739 40 39 39 43
OUTVOT
B400 20
A
20
140
C
80
B400 20
20
A
140
C
80
OUTVL-OUTVOT
B
360 63
20
AC
100
INVOT
B
360
63
100
A
C
200
INVOT
TEC
HN
ICA
L D
ATA
ELFORoom2 cased version OUTVOT-OUTVL ELFORoom2 uncased version INVOT
Cased vertical/horizontal installationwith remote thermostat
Cased vertical installationwith termostat on board
Uncased vertical/horizontal installationwith remote thermostat
Size 003.0 005.0 011.0 015.0 017.0A - Length mm 527 727 927 1127 1327B - Width mm 130 130 130 130 130C - Height mm 586 586 586 586 586Operating weight Kg 9 12 15 18 21
Size 003.0 005.0 011.0 015.0 017.0A - Length mm 737 937 1137 1337 1537B - Width mm 130 130 130 130 130C - Height mm 579 579 579 579 579Operating weight Kg 17 20 23 26 29
The above mentioned data are referred to standard units.
DIMENSIONS
TECHNICAL DATA
Size – ELFOROOM2 Cooling capacity (1) kWSensible capacity (1) kWTotal power input (1) kW Heating capacity (2) kW
Supply airflow (3) l/sType of supply fan (4) -Standard power supply (5) VL Sound pressure level (6) dB(A)M Sound pressure level (6) dB(A)H Sound pressure level (6) dB(A)
Notes
(1) Ambient air at 27°C/19.5 W.B.; inlet water 7°C and outlet 12°C; Air flow at max speed measured with clean filters
(2) Ambient temperature 20°C DB; Water inlet 45°C and outlet 40°C; Air flow at max speed measured with clean filters
(3) Air flow at max speed measured with clean filters(4) TGZ=tangential(5) Power supply 230/1/50 Hz +/-10%(6) The values have been detected in a closed ambient with a volume of 100 m³ and a reverberation
time of 0.5 seconds. The sound levels are referred to unit operating at a full load in nominal
conditions. The sound pressure level is referred at a distance of 1m. from the external unit surface, with fairing, fitted to a wall. Please note that when the unit is installed in conditions other than nominal test conditions /for example near walls or obstacles in general) the sound levels may undergo substantial variation.
L Low speed (L)M Medium speed (M)H High speed (H)
CAUTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.
65
Water room terminal
ELFOControl2Refrig. WATER
ACCESSORIES
DC Motor
Size– ELFOROOM2 003.0 005.0 011.0 015.0 017.0
Basic configuration (OUTVL - 230/1/50) Vertical cased with LCD display, continuous modulation DC motor, RS485 interface and built-in thermostat
std std std std std
Basic configuration (OUTVOT - 230/1/50)Vertical - Horizontal cased with continuous modulation DC motor, RS485 interface without built-in thermostat
std std std std std
Basic configuration (INVOT - 230/1/50) Vertical - Horizontal uncased with continuous modulation DC motor, RS485 interface without built-in thermostat
std std std std std
Basic configuration (OUTRAD - 230/1/50) Vertical cased with continuous modulation DC motor, RS485 interface with built-in thermostat and ventilated radiant plate
std std std std std
Basic configuration (OUTSRAD - 230/1/50) Vertical cased with continuous modulation DC motor, RS485 interface, without built-in thermostat and with ventilated radiant plate
std std std std std
Basic configuration (INRAD - 230/1/50) Vertical uncased with continuous modulation DC motor, RS485 interface, without built-in thermostat and with ventilated radiant plate (Available only with PCIX-CSFIX)
std std std std std
B4T Additional coil for 4-pipe syst.KASPX Return plenum kitGMX Outlet grilleGRA1X Air outflow grillePR90MX 90° air outlet plenumPMSTX Telescopic upper supply plenum kitKV3B4X 3-way valve kit with electrothermal head and balancing for 4-pipe system (Available only with B4T)KV3VBX 3-way valve kit with electrothermal head and balancingCSEMP Simplified electronic control with 4 speeds DC motor, built-in thermostat without RS485 interface (with option: OUTVL)CSEMP Simplified electronic control with 4 speeds DC motor, built-in thermostat without RS485 interface (with option: OUTRAD)3V010 DC motor modulation electronic board for matching to 3 speeds and 0-10V thermostats without RS485 interface (with option: OUTVL)3V010 DC motor modulation electronic board for matching to 3 speeds and 0-10V thermostats without RS485 interface (with option: OUTRAD)3V010 DC motor modulation electronic board for matching to 3 speeds and 0-10V thermostats without RS485 interface (with option: OUTVOT)3V010 DC motor modulation electronic board for matching to 3 speeds and 0-10V thermostats without RS485 interface (with option: OUTSRAD)3V010 DC motor modulation electronic board for matching to 3 speeds and 0-10V thermostats without RS485 interface (with option: INVOT)3V010 DC motor modulation electronic board for matching to 3 speeds and 0-10V thermostats without RS485 interface (with option: INRAD)HIDE1X Remote control with 3 position switch + on/off for wall installation (Available only with 3V010)HIDE2X Remote control with E/I +3V +on/off for wall installation (Available only with 3V010)HIDE3X Plurifunctional remote control for wall installation (Available only with 3V010)HIDT2X HID-T2 electronic room controlHIDT3X HID-T3 electronic room controlHIDTI2X HID-TI2 Flush-mounted electronic room controlKCMDX Motor connection cables for unit with couplings on the rightBACKVX Painted rear panel for cased versionPCIX Uncased closure panelCSFIX Formwork for uncased installationFXPPX Floor fixing bracket kitKPDX Plinth kitUV UV germicidal lamp kit with support
Accessories whose code ends with "X" are separately supplied.
66
TEC
HN
ICA
L D
ATA
Functionalities Accessories
Internal suction and supply grilles
AIRJET 50/I supply diff user - white frame and black inside
AIRJET 80/I supply diff user - white frame and black inside
Intake grille + extractable fi lter AIRJET 50/A - white frame and black inside
Intake grille + extractable fi lter AIRJET 80/A - white frame and black inside
Suction/supply plenum with AIRJET 50 control damper - rear connection
Suction/supply plenum with AIRJET 80 control damper - rear connection
Suction/supply rectangular grill 350x130mm stainless
Suction/supply rectangular grill 350x130mm white
Filter for rectangular grilles 350x130mm (5pz.)
Extraction/intake valve in ABS DN125 without air fi lter
Filter for DN125 valve (5pz.)
Extraction/intake squared grill of DN125 joint with air fi lter
Flat tube distribution (from the distribution box to outlet)
Flat fl exible tube 132x52mm in a 20mt. coil without insulation
Insulation in a 20mt. coil for fl at fl exible tube 132x52
Connector to distribution box for fl at tube
Seal and connecting joint for fl at tube (10pz.)
Vertical 90-degree curve for fl at tube
Horizontal 90-degree curve for fl at tube
Joint for 180-degree fl at tube rotation
90-degree adaptor, single tube for DN125 valve
90-degree adaptor, double fl at tube for DN125 valve
Straight adaptor, single fl at tube for DN125 valve
90-degree adaptor, single fl at tube for level grill
Blind plug for fl at tube (5pz.)
Fixing ring for fl at tube (10pz.)
Flow controller for fl at tube
Round/fl at tube connecting joint
ACCESSORIES
ELFOAir
DAIR50X
DAIR80X
GAIR50X
GAIR80X
PAIR50X
PAIR80X
GINOX
GIVEX
FREX
VIEX
FT125X
GQIEX
TFPNX
IT100X
COBPX
GIUPX
CVP90X
COP90X
CTP180X
A90MPX
A90DPX
ADMPX
A90GPX
TACPX
ANFPX
REPPX
RTPTX
67
TFT90X
IT90X
CBT90X
GIUTX
CT90X
A90DTX
TACTX
ANFTX
BD8CX
BD14CX
TFIS150X
TFIS200X
TFIS250X
GR150X
GR200X
GR250X
GF150X
GF200X
GF250X
R2015X
R2520X
DY200X
DY250X
GPRX
PRX
CPRX
The air distribution system for ELFOFresh2 and ELFOPack - Accessories
Round tube distribution (from the distribution box to outlet)
DN90 round fl exible tube (Int. diam. 78mm) in a 20m. coil without insulation
Insulation in a 20mt. coil for DN90 round fl exible tube
Connector to distribution box for DN90 round tube
Connecting joint for DN90 round tube
Printed curve of 90-degree angle for DN90 round tube
90-degree adaptor, double DN90 round tube for DN125 valve
Blind plug for DN90 round tube (5pz.)
DN90 seal O-Ring (10pz.)
External distribution (Ducts from the outside to the unit and from the unit to the distribution boxes)
Distribution box of DN150-200 joint with 8 connections
Distribution box of DN200 joint with 14 connections
DN150 soundproofi ng insulated fl exible tube in a 10mt. coil
DN200 soundproofi ng insulated fl exible tube in a 10mt. coil
DN250 soundproofi ng insulated fl exible tube in a 10mt. coil
Exhaust / return square wall grille with circular coupling DN150
Exhaust / return square wall grig with circular coupling DN200
Exhaust / return square wall grig with circular coupling DN250
F/F DN150 Joint
F/F DN200 Joint
F/F DN250 Joint
DN200-DN150 Reducer
DN250-DN200 Reducer
DN200-DN200-DN200 Y-branch
DN250-DN200-DN200 Y-branch
Air recirculation (ELFOPack only)
Grill for recirculation air return plenum 325x175 mm white
Soundproofed plenum for air recirculation
Manifold for air recirculation plenum DN150-200
For technical details see technical bulletin
68
ELFOControl2
TEC
HN
ICA
L D
ATA
TECHNICAL DATA
ELFOControl²Display dimensions inches 7,2”Display type TFT colorPower supply voltage Vdc 12Power VA 24Protection rating IP 20Weight kg 0.5
DIMENSIONS
Power supply Converter
ELFOControl2 is supplied with:
12Vdc AL12X power supply unit (4 DIN modules)
Ethernet/485 converter (3 DIN modules)
Cat. 5 UTP Ethernet cable (5m long)
NOTE: the maximum distance between the Ethernet/485 converter and ELFOControl2 is 90 meters
CONTROL CHARACTERISTICS
Maximum of 12 climate areas
2 pipe system
Maximum of 40 elements manageable
Maximum of 1 heat pump: GAIA Aria, GAIA Acqua, GAIA Maxi Hybrid, GAIA L Comfort, GAIA L Hybrid, GAIA i, ELFOEnergy Extended Inverter, ELFOEnergy
Horus, ELFOEnergy Horus+,ELFOEnergy Ground, ELFOEnergy Duct Inverter, ELFOEnergy Vulcan, ELFOEnergy Medium,
ELFOEnergy Vulcan Medium.
Maximum 4 unit for mechanical ventilation: ElfoFresh², ELFOFresh Large.
Hydronic terminal units : ELFORoom² 003.0-017.0, ELFOSpace 003.0 - 051.0, ELFODuct MP 15 - 71, ELFODuct HP 015.0 - 071.0,
ELFOSPACE BOX2 005.1 - 041.0, ELFOSpace WALL 005.0 - 017.0, ELFODuct CF-V 31 - 242
Maximum of 4 radiant modules - BMZRX
Maximum of 3 mixed zones (including intra Gaia) KGPRX
Single zone module - CMRSX
Input/Output Module - MIOX
Maximum of 1 connection device with domotics - DOMX
69
DOMX 53 x 92 x 63 mm
HID-T3X 184 x 82 x 27 mm
HIDT2X 184 x 82 x 27 mm
HID-TI2X 65 x 45 x 54 mm
HIDTi5NX 121 x 94 x 19 mm
HIDTi5BX 121 x 94 x 19 mm
HIDURNX 22 x 45 x 50 mm
HIDURBX 22 x 45 x 50 mm
BMZRX157 x 90 x 60 mm
AL12X85 x 90 x 65 mm
CMRSX105 x 90 x 60 mm
CIECX 216 x 168 x 73 mm
CBSX
KGPRX 210 x 155 x 80 mm
MIOX70 x 85 x 65 mm
Control unit for independent residential systems
ACCESSORIES
Functionalities Accessories Dimensions
Home automation system connection
Device for connection with home automation systems
Communication with the room thermostat for temperature and humidity control.
Temperature and humidity thermostat – wall installation
Temperature only thermostat – wall installation
Temperature only thermostat – recessed installation
Temperature and humidity thermostat with touch screen display, for built-
in installation (box 503) or for wall installation.
Colour black
Temperature and humidity thermostat with touch screen display, for built-
in installation (box 503) or for wall installation.
Colour white
Temperature and humidity sensor - built-in installation. Colour black
Temperature and humidity sensor - built-in installation. Colour white
Floor radiant panel management (heating and cooling), radiators, towel rail
Module to manage up to 6 HID thermostats and 6 control outputs, shut-off
valves to feed radiant panels, radiators or heating furniture 9 Modules DIN
Power supply unit for HID-Ti5 thermostats and HID-UR sensor4 Modules DIN
Module to manage up to 1 HID thermostat and 1 control output, shut-off
valves to feed radiant panels, radiators or heating furniture 6 Modules DIN
Elements for the complete installation
Allows recessed installation of ELFOControl2
Shielded cable for the connection to all devices 50 meter skein
GAIA includes all system elements such as domestic hot water production with 186 liters water storage tank and up to a maximum of three pumps for the secondary circuit, two with
possible mixing valve. These components are already connected to the control of GAIA and is therefore it is not necessary to use other control elements connected to ELFOControl2.
If the system, controlled by ELFOControl2. includes GAIA, with a system that requires more pumps than the three internal, or one of the other Clivet heat pumps , the control of all com-
ponents external to the heat pump must be managed with the following elements.
Dual temperature system
Management module of a mixing group
Zone valve, circulatingpump and remote consent management
Module for management of substitution generator (boiler), zone valves or
boosters and remote consent 4 Modules DIN
70
ELFOSun
TEC
HN
ICA
L D
ATA
DimensionsLength L mm 2005Height C mm 1290Thickness H mm 100Collector pipes G mm 22Pipe length F mm 1340Pipes distance M mm 1880Weight Kg 50
DIMENSIONS
TECHNICAL DATA SINGLE PANEL
Solar panel Rif.
Net absorbent surface 2,305 m2
Open surface 2,345 m2
Gross collector surface 2,586 m2
Glass V Extra light, tempered, prismatic
Absorbent plate B Copper
Surface coating B Selective TITAN (titanium oxide)
Efficiency (open surface) η0
0,716
Loss ratio (open surface)α
1
α2
3,87 W/m2K
0,0069 W/m2K2
Absorptance A 95%
Emittance E 4,7%
Advised panel flow 130 l/h
Collector water capacity 2 l
Max. pressure 10 bar
Stagnant temperature 192°C
Casing material O Aluminum
Insulation thickness R 45 mm
Standard case color Brown / RAL8017
71
ACCESSORIES
Description
2CSPX No. of 2 H1TX fl at Solar collectors at high effi ciency
3CSPX No. of 3 H1TX fl at Solar collectors at high effi ciency
KFTI2X Fixing system for pitched roofs for the 2-collector installation
KFTI3X Fixing system for pitched roofs for the 3-collector installation
KFSP2X Fixing system for fl at surfaces for the 2-collector installation
KFSP3X Fixing system for fl at surfaces for the 3-collector installation
KFIN2X Uncased fi xing system for the 2-collector installation
KFIN3X Uncased fi xing system for the 3-collector installation
KCVEX Circulation kit : circulation group, control unit, expansion tank
GP10X Concentrated propylene glycol 10-liters
Accessories whose code ends with "X" are separately supplied.
Available from April 2016
72
TEC
HN
ICA
L D
ATA
21 31 41 51 71 81 91 101 121 131 141 151 161 171
5,41 6,81 8,70 11,9 14,3 16,6 18,5 19,7 23,7 28,8 32,9 37,2 43,9 50,2
1,29 1,65 2,13 2,94 3,51 4,07 4,68 5,04 5,74 7,06 8,33 9,79 11,6 13,4
4,19 4,12 4,09 4,05 4,07 4,08 3,95 3,91 4,13 4,08 3,95 3,80 3,80 3,74
4,27 5,38 6,95 9,58 11,5 13,3 14,6 16,4 19,8 22,7 26,1 29,5 34,8 39,8
1,27 1,62 2,11 2,91 3,50 4,04 4,65 5,21 5,93 6,92 8,16 9,58 11,3 13,1
3,36 3,32 3,30 3,29 3,29 3,29 3,14 3,15 3,34 3,28 3,20 3,08 3,08 3,04
3,27 4,14 5,49 7,35 8,83 10,6 11,9 12,9 14,5 17,6 20,4 23,1 27,2 31,2
1,23 1,50 2,01 2,76 3,34 4,00 4,61 5,02 5,60 6,74 7,85 9,17 10,9 12,5
2,66 2,76 2,73 2,66 2,64 2,65 2,58 2,57 2,59 2,61 2,60 2,52 2,50 2,49
4,25 6,34 8,07 10,4 13,0 15,9 17,6 19,4 25,4 30,8 35,0 39,8 45,4 50,9
1,14 1,74 2,11 2,87 3,46 4,15 4,61 5,32 6,51 8,35 8,95 10,6 11,9 13,8
3,73 3,64 3,82 3,62 3,76 3,83 3,82 3,65 3,90 3,69 3,91 3,77 3,82 3,68
5,19 6,54 8,25 11,5 13,8 16,2 18,6 20,5 25,8 27,2 31,9 36,7 43,0 49,3
1,60 2,02 2,57 3,61 4,33 5,05 5,92 7,00 8,04 8,58 9,88 11,5 13,6 15,7
3,24 3,23 3,21 3,19 3,19 3,21 3,14 2,93 3,21 3,17 3,23 3,20 3,17 3,14
4,10 5,18 6,57 9,19 11,1 13,3 14,9 16,3 21,0 21,6 25,4 29,3 34,4 39,5
1,56 1,97 2,49 3,58 4,32 4,98 5,82 6,88 7,92 8,44 9,69 11,3 13,3 15,4
2,63 2,63 2,64 2,57 2,57 2,67 2,56 2,37 2,65 2,56 2,62 2,60 2,58 2,56
3,17 4,02 5,17 7,17 8,63 10,4 11,9 13,3 16,0 17,0 20,2 23,3 27,4 31,6
1,45 1,82 2,31 3,41 4,15 4,86 5,67 6,68 7,69 8,21 9,44 10,9 13,0 14,9
2,18 2,21 2,24 2,10 2,08 2,14 2,10 1,99 2,08 2,07 2,14 2,13 2,11 2,12
3,88 5,24 6,10 8,84 11,7 15,4 16,8 19,4 24,1 28,2 32,5 38,2 43,6 49,2
1,50 2,05 2,34 3,44 4,55 5,52 6,06 8,15 9,41 10,3 12,2 14,4 16,2 19,1
2,58 2,55 2,61 2,57 2,57 2,79 2,77 2,38 2,56 2,74 2,67 2,66 2,69 2,58
4,41 4,07 3,86 4,17 4,81 5,01 5,14 4,70 5,13 4,14 4,00 3,69 3,66 3,55
5,05 6,39 8,03 11,0 13,3 15,2 17,7 19,9 24,0 25,0 30,3 34,2 40,1 46,7
1,94 2,45 3,16 4,35 5,28 6,18 7,25 8,61 10,2 10,5 11,9 13,6 16,1 18,5
2,60 2,61 2,54 2,53 2,52 2,46 2,44 2,31 2,35 2,39 2,55 2,51 2,49 2,52
3,99 5,04 6,37 8,92 10,7 12,2 14,4 16,0 19,5 20,0 24,5 27,6 32,2 37,5
1,86 2,34 3,00 4,31 5,22 6,10 7,20 8,51 10,1 10,3 11,8 13,5 15,9 18,3
2,14 2,15 2,12 2,07 2,05 2,00 2,00 1,88 1,94 1,94 2,08 2,05 2,02 2,05
3,10 3,92 4,99 7,08 8,57 9,90 11,6 13,1 15,4 16,1 - - - -
1,68 2,11 2,70 4,16 5,07 5,96 6,99 8,24 9,81 10,1 - - - -
1,84 1,86 1,85 1,70 1,69 1,66 1,66 1,59 1,57 1,60 - - - -
0,26 0,33 0,42 0,57 0,68 0,79 0,88 0,94 1,13 1,38 1,57 1,78 2,10 2,40
54 49 39 38 41 63 60 58 75 116 121 110 96 76
230/1/50 400/3/50+N
49 49 49 53 54 56 56 57 55 63 69 70 73 73
-20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20
60 60 60 60 60 60 60 60 60 60 60 60 60 60
Size – WSAN-XIN (Excellence)
Unit for radiant panels
A7/W35 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
A2/W35 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
A-7/W35 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
A35/W18 Cooling capacity kW
Total power input kW
EER (EN 14511:2013) -
Terminal units
A7/W45 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
A2/W45 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
A-7/W45 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
A35/W7 Cooling capacity kW
Total power input kW
EER (EN 14511:2013) -
ESEER -
Radiators
A7/W55 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
A2/W55 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
A-7/W55 Heating capacity kW
Total power input kW
COP (EN 14511:2013) -
Water flow-rate (User Side) (1) l/s
Useful pump discharge head (1) kPa
Standard power supply V
Sound pressure level (1m) outdoor unit dB(A)
Min inlet air temperature (W.B.) °C
Max. leaving water temperature °C
Notes
(1) A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
Performances according to EN 14511:2013
A7/W35 internal exchanger water 30/35°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W35 internal exchanger water 30/35°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W35 internal exchanger water 30/35°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W45 internal exchanger water 40/45°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W45 internal exchanger water 40/45°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W45 internal exchanger water 40/45°C; external air temperature -7°C D.B./ -8°C W.B.
A7/W55 internal exchanger water 50/55°C; external air temperature 7°C D.B./ 6°C W.B.
A2/W55 internal exchanger water 50/55°C; external air temperature 2°C D.B./ 1,1°C W.B.
A-7/W55 internal exchanger water 50/55°C; external air temperature -7°C D.B./ -8°C W.B.
A35/W18 internal exchanger water 23/18°C; external air temperature 35°C
A35/W7 internal exchanger water 12/7°C; external air temperature 35°C
ELFOEnergy Extended Inverter(WSAN-XIN 21-171)
TECHNICAL DATA
73
21 31 41 51 71 81 91 101 121 131 141 151 161 171A+ A+ A+ A+ A+ A+ A+ A+ A+ A+ A+ A A AA+ A+ A+ A+ A+ A+ A+ A+ A+ A+ - - - -
4,16 4,07 4,48 4,10 4,18 4,48 4,26 4,18 4,45 3,53 3,56 3,37 3,31 3,364,14 4,04 4,41 4,05 4,15 4,38 4,14 4,06 4,36 3,56 3,57 3,37 3,31 3,354,61 4,73 4,91 4,36 4,51 4,74 4,55 4,43 4,76 3,88 3,90 3,67 3,63 3,64
21 31 41 51 71 81 91 101 121 131 141 151 161 171942 942 942 1087 1087 1731 1731 1731 1731 1341 1341 1341 1341 1341433 433 433 445 445 724 724 724 724 1159 1159 1159 1146 1146992 992 992 1234 1234 1137 1137 1137 1517 1520 1520 1520 1770 1770400 400 400 400 400 400 400 400 400 1000 1000 1000 1000 1000600 600 600 600 600 600 600 600 600 1000 1000 1000 1000 1000400 400 400 400 400 400 400 400 400 1000 1000 1000 1000 1000112 116 124 170 175 240 240 240 310 300 310 330 400 400
21 31 41 51 71 81 91 101 121 131 141942 942 942 1087 1087 1731 1731 1731 1731 1731 1731433 433 433 445 445 724 724 724 724 724 724992 992 992 1234 1234 1137 1137 1137 1517 1517 1517400 400 400 400 400 400 400 400 400 400 400600 600 600 600 600 600 600 600 600 600 600400 400 400 400 400 400 400 400 400 400 400112 116 124 170 175 240 240 240 310 310 310
CAUTION! For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.
Version:PRM PremiumEXC Excellence
Size – WSAN-XINEXC A - Length mmEXC B - Width mmEXC C - Height mmEXC A1 mmEXC A2 mmEXC B2 mmEXC Operating weight kg
Size – WSAN-XINPRM A - Length mmPRM B - Width mmPRM C - Height mmPRM A1 mmPRM A2 mmPRM B2 mmPRM Operating weight kg
Two-section air-water reversible heat pump with integration boiler
ELFOControl2 Full Inverter DCRefrigerant R-410A
Size – WSAN-XIN (EXCELLENCE)ErP System Energy Class - AVERAGE Climate - W35 (1) -ErP System Energy Class - AVERAGE Climate - W55 (1) -Efficiency on specific locations -SCOP Glsagow (2) -SCOP London (2) -SCOP Plymouth (2) -
Notes
The Product is compliant with the ErP (Energy Related Products) European Directive. It includes the Commission delegated Regulation (EU) No 811/2013 (rated heat output ≤ 70 kW at specified reference conditions) and the Commission delegated Regulation (EU) No 813/2013 (rated heat output ≤ 400 kW
at specified reference conditions)(1) Seasonal Space Heating Energy Efficiency Class according to Commission delegated Regulation
(EU) No 811/2013. W = Water outlet temperature (°C)
(2) SCOP values calculated by similar procedure as indicated in the UNI 14825 using frequency values of hourly occurrence (BIN) of the indicated locations, with water temperature for radiant panels and thermal power to T_design equal to the capacity declared for the European ErP Directive for Climate High Temperature Heat Pumps.
SIZE – WSAN-XIN 21 31 41 51 71 81 91 101 121 131 141 151 161 171Basic configuration (230/1/50) Excellence std std std option option - - - - - - - - -
Basic configuration (400/3/50) Excellence - - - std std std std std std std std std std std
Basic configuration (230/1/50) Premium std std std option option - - - - - - - - -
Basic configuration (400/3/50) Premium - - - std std std std std std std std - - -
For Premium (PRM) version details, refer to the relative Technical Bulletin.
HEDIF Diffuser for high efficiency axial fan (only for Excellence)ACS3SX 300-litre domestic hot water storage tank with solar coilACS300X 300-litre domestic hot water storage tankACS500X 500-litre domestic hot water storage tankACS5SX 500-litre domestic hot water storage tank with solar coil3DHWX Three-way valve for domestic hot water- User side hydronic assembly: not required (version Excellence)- User side hydronic assembly: not required (version Premium)KSAX 100-litre circuit breakerKTFLX Hose kit for connection to the chiller/heat pump.CMACSX Domestic hot water moduleCMSC2X Serial communication module with RS485 serial converter kitRCTX Remote controlAMRX Rubber antivibration mountsPGFCX Finned coil protection grill (version Excellence)PGFCX Finned coil protection grill (version Premium)KG4UPX Management kit up to 4 units in parallel by the two set point available for each unit
Accessories whose code ends with "X" are separately supplied.
ACCESSORIES
DIMENSIONS
ErP
55 °C 35 °C
dB
dB
kW kW
2015 811/2013
A++
A+
A B C D E F G
A+ A+
Clivet S.p.A. WSAN XIN
121829
111831
00
74
74
EPK
-00
00
0-1
M/R
00
DW
G v
ers
ion
av
ail
ab
le o
n w
ww
.cli
ve
t.co
mTh
e d
iag
ram
is p
ure
ly in
dic
ativ
e. T
he
exe
cuti
ve d
esi
gn
an
d s
ub
seq
ue
nt
inst
alla
tio
n m
ust
be
car
rie
d o
ut
in c
om
plia
nce
wit
h t
he
re
gu
lati
on
s in
fo
rce.
Air
-Air
he
at p
um
p fo
r to
tal c
om
fort
/ F
lat
70
m²
ELFOPack
SYST
EM S
CH
EME
75
Heat Pump• Heating
• DHW Production
• Cooling
• Air renewal
• Summer dehumidification
• Thermodynamic recovery
• Freecooling
ELFOPack [CPAR- XIN]
Reversible heat pump
Distribution systemELFOAir:
Air distribution system
Accessories
• 7 x DAIR80X: AIRJET 80/I supply diffuser - white frame and black inside
• 7 x PAIR80X: Suction/supply plenum with AIRJET 80 control damper - rear connection
• 2 x VIEX: Extraction/intake valveDN125
• 2 x FT125X: Filter for DN125 valve (5pz.)
• 2 x TFT90X: DN90 round flexible tube (Int. diam. 78mm) in a 20m. coil without insulation
• 2 x IT90X: Insulation in a 20mt. coil for DN90 round flexible tube
• 16 x CBT90X: Connector to distribution box for DN90 round tube
• 1 x A90DTX: 90-degree adaptor, double DN90 round tube for DN125 valve
• 2 x ANFTX: DN90 seal O-Ring (10pz.)
• 1 x TFPNX: Flat flexible tube 132x52mm in a 20mt. coil
• 1 x IT100X: Insulation in a 20mt. coil for flat flexible tube 132x52
• 1 x GIUPX: Seal and connecting joint for flat tube (10pz.)
• 1 x A90MPX: 90-degree adaptor, single tube for DN125 valve
• 1 x ANFPX: Fixing ring for flat tube (10pz.)
• 1 x RTPTX : Round/flat tube connecting joint
• 1 x BD8CX: Distribution box of DN150-200 joint with 8 connections
• 1 x BD14CX: Distribution box of DN200 joint with 14 connections
• 1 x TFI150X: DN150 soundproofing insulated flexible tube
• 2 x TFI200X: DN200 soundproofing insulated flexible tube
• 2 x GR200X: Exhaust / return square wall grig with circular coupling DN200
• 1 x GPRX: Grill for recirculation air return plenum 325x175 mm white
• 1 x PRX: Soundproofed plenum for air recirculation for tube DN90 x 5 connections
• 1 x CPRX: Manifold for air recirculation plenum DN150-200
Plant Elements
76
ELFOSystem GAIA Aria
Wat
er-
air
he
at p
um
p +
so
lar
inte
gra
tio
n +
3 w
ate
r ci
rcu
its
+ C
MV
wit
h t
he
rmo
dyn
amic
re
cove
ry
GA
A-F
CS0
0-3
3/R
00
DW
G v
ers
ion
av
ail
ab
le o
n w
ww
.cli
ve
t.co
m
SYST
EM S
CH
EME
The
dia
gra
m is
pu
rely
ind
icat
ive.
Th
e e
xecu
tive
de
sig
n a
nd
su
bse
qu
en
t in
stal
lati
on
mu
st b
e c
arri
ed
ou
t in
co
mp
lian
ce w
ith
th
e r
eg
ula
tio
ns
in f
orc
e.
77
Heat Pump• Heating
• DHW Production
• Cooling
• Solar integration on the DHW system
• System domotics with advanced algorithms
for optimising energy and comfort
GAIA Aria [MSER - XEE]:
Two-section reversible heat pump with ELFOControl2
Accessories
• 2 x KIRLX: Booster hydraulic kit separately supplied
• 1 x SRILX: Additional card for second and third booster management
• 1 x EH04: Modulating integration electric heater from 0 to 4kw (size 31)
• 1 x EH246: Modulating integration electric heater from 2-4 to 6 kW (size 61)
ELFOControl2:
Control for independent residential systems
Includes
• Power supply unit 12 V DC AL12X (4 modules DIN)
• Converter Ethernet/485 (3 modules DIN)
• Cable Ethernet UTP cat 5 (length 5 m)
Accessories
• 2 x AL12X: Power supply unit for HID-Ti5 thermostats and HID-UR sensor
• 2 x BMZRX: Module to manage up to 6 HID thermostats and 6 control outputs,
shut-off valves to feed radiant panels, radiators or heating furniture.
+ TTL-RS485 serial converter
• 1 x CBSX: Shielded cable for the connection to all devices (Modbus RS485 cable)
• 1 x CIECX : Allows recessed installation of ELFOControl²
• 2 x CMRSX: Module to manage up to 1 HID thermostat and 1 control output,
shut-off valves to feed radiant panels, radiators or heating furniture.
+ TTL-RS485 serial converter
• 6 x HID-Ti5NX: Temperature and humidity thermostat with touch screen display,
for uncased (box 503) or wall installation. Colour black
Heat recovery• Air renewal
• Thermodynamic recovery
• Summer dehumidification
• Freecooling
ELFOFresh2 [CPAN-U]:
Air renewal and purification unit, full fresh air
Configuration
• Cooling and heating operation
Accessories
• 1 x FES: Electronic filters
• 1 x CMMBX: Serial communication module to supervisor (Modbus)
Plant terminal unitsELFORoom2:
Water terminal unit, vertical and horizontal indoor installation, cased or uncased Configuration
• OUTVOT: Vertical cased with LCD display, continuous modulation DC motor,
RS485 interface and built-in thermostat
78
ELFOSystem GAIA L Comfort
GLC
-FC
S00
-11
/R0
0
DW
G v
ers
ion
av
ail
ab
le o
n w
ww
.cli
ve
t.co
m
Wat
er-
air
he
at p
um
p +
so
lar
inte
gra
tio
n +
1 w
ate
r ci
rcu
it +
CM
V w
ith
th
erm
od
ynam
ic r
eco
very
SYST
EM S
CH
EME
The
dia
gra
m is
pu
rely
ind
icat
ive.
Th
e e
xecu
tive
de
sig
n a
nd
su
bse
qu
en
t in
stal
lati
on
mu
st b
e c
arri
ed
ou
t in
co
mp
lian
ce w
ith
th
e r
eg
ula
tio
ns
in f
orc
e.
79
Heat Pump• Heating
• DHW Production
• Cooling
• Solar integration on the DHW system
GAIA L Comfort [GLC]:
Two-section reversible heat pump
Configuration
• SOL: Drain-back solar integration for domestic hot water
Accessories
• 1 x EH246: Modulating integration electric heater from 2-4 to 6 kW
Control• System domotics with advanced algorithms
for optimising energy and comfort
ELFOControl2:
Control for independent residential systems
Includes
• Power supply unit 12 V DC AL12X (4 modules DIN)
• Converter Ethernet/485 (3 modules DIN)
• Cable Ethernet UTP cat 5 (length 5 m)
Accessories
• 2 x AL12X: Power supply unit for HID-Ti5 thermostats and HID-UR sensor
• 2 x BMZRX: Module to manage up to 6 HID thermostats and 6 control outputs,
shut-off valves to feed radiant panels, radiators or heating furniture.
+ TTL-RS485 serial converter
• 1 x CBSX: Shielded cable for the connection to all devices (Modbus RS485 cable)
• 1 x CIECX : Allows recessed installation of ELFOControl²
• 6 x HID-Ti5NX: Temperature and humidity thermostat with touch screen display,
for uncased (box 503) or wall installation. Colour black
Heat recovery• Air renewal
• Thermodynamic recovery
• Summer dehumidification
• Freecooling
ELFOFresh2 [CPAN-U]:
Air renewal and purification unit, full fresh air
Configuration
• Cooling and heating operation
Accessories
• 1 x FES: Electronic filters
• 1 x CMMBX: Serial communication module to supervisor (Modbus)
Plant Elements
80
ELFOSystem GAIA L Hybrid
Wat
er-
air
he
at p
um
p +
so
lar
inte
gra
tio
n +
bo
iler
inte
gra
tio
n +
1 w
ate
r ci
rcu
it +
CM
V w
ith
th
erm
od
ynam
ic r
eco
very
GLH
-FC
S00
-11
/R0
0
DW
G v
ers
ion
av
ail
ab
le o
n w
ww
.cli
ve
t.co
m
SYST
EM S
CH
EME
The
dia
gra
m is
pu
rely
ind
icat
ive.
Th
e e
xecu
tive
de
sig
n a
nd
su
bse
qu
en
t in
stal
lati
on
mu
st b
e c
arri
ed
ou
t in
co
mp
lian
ce w
ith
th
e r
eg
ula
tio
ns
in f
orc
e.
81
Heat Pump• Heating
• DHW Production
• Cooling
• Solar integration on the DHW system
• Condensing boiler integration on the plant
and DHW system
GAIA L Hybrid [GLH]:
Two-section reversible heat pump
Configuration
• SOL: Drain-back solar integration for domestic hot water
Control• System domotics with advanced algorithms
for optimising energy and comfort
ELFOControl2:
Control for independent residential systems
Includes
• Power supply unit 12 V DC AL12X (4 modules DIN)
• Converter Ethernet/485 (3 modules DIN)
• Cable Ethernet UTP cat 5 (length 5 m)
Accessories
• 2 x AL12X: Power supply unit for HID-Ti5 thermostats and HID-UR sensor
• 2 x BMZRX: Module to manage up to 6 HID thermostats and 6 control outputs,
shut-off valves to feed radiant panels, radiators or heating furniture.
+ TTL-RS485 serial converter
• 1 x CBSX: Shielded cable for the connection to all devices (Modbus RS485 cable)
• 1 x CIECX : Allows recessed installation of ELFOControl²
• 6 x HID-Ti5NX: Temperature and humidity thermostat with touch screen display,
for uncased (box 503) or wall installation. Colour black
Heat recovery• Air renewal
• Thermodynamic recovery
• Summer dehumidification
• Freecooling
ELFOFresh2 [CPAN-U]:
Air renewal and purification unit, full fresh air
Configuration
• Cooling and heating operation
Accessories
• 1 x FES: Electronic filters
• 1 x CMMBX: Serial communication module to supervisor (Modbus)
Plant Elements
82
GM
A-F
CS0
0-3
4/R
00
DW
G v
ers
ion
av
ail
ab
le o
n w
ww
.cli
ve
t.co
m
Wat
er-
air
he
at p
um
p +
so
lar
inte
gra
tio
n +
bo
iler
inte
gra
tio
n +
4 w
ate
r ci
rcu
its
+ C
MV
wit
h t
he
rmo
dyn
amic
re
cove
ry
ELFOSystem GAIA Maxi Hybrid
SYST
EM S
CH
EME
The
dia
gra
m is
pu
rely
ind
icat
ive.
Th
e e
xecu
tive
de
sig
n a
nd
su
bse
qu
en
t in
stal
lati
on
mu
st b
e c
arri
ed
ou
t in
co
mp
lian
ce w
ith
th
e r
eg
ula
tio
ns
in f
orc
e.
83
Heat Pump• Heating
• DHW Production
• Cooling
• Solar integration on the DHW system
• Condensing boiler integration
on DHW system
• System domotics with advanced algorithms
for optimising energy and comfort
GAIA Maxi [MSER - XIN]:
Packaged heat pump with condensing boiler with ELFOControl2
Configuration
• Solar integration for DHW
Accessories
• 1x KIR4HLL: 4 zones, one at high temperature + three at low temperature (mix)
• 1 x SRILX: Additional card for second and third booster management
ELFOControl2:
Control for independent residential systems
Includes
• Power supply unit 12 V DC AL12X (4 modules DIN)
• Converter Ethernet/485 (3 modules DIN)
• Cable Ethernet UTP cat 5 (length 5 m)
Accessories
• 2 x AL12X: Power supply unit for HID-Ti5 thermostats and HID-UR sensor
• 2 x BMZRX: Module to manage up to 6 HID thermostats and 6 control outputs,
shut-off valves to feed radiant panels, radiators or heating furniture.
+ TTL-RS485 serial converter
• 1 x CBSX: Shielded cable for the connection to all devices (Modbus RS485 cable)
• 1 x CIECX : Allows recessed installation of ELFOControl²
• 2 x CMRSX: Module to manage up to 1 HID thermostat and 1 control output,
shut-off valves to feed radiant panels, radiators or heating furniture.
+ TTL-RS485 serial converter
• 6 x HID-Ti5NX: Temperature and humidity thermostat with touch screen display,
for uncased (box 503) or wall installation. Colour black
Heat recovery• Air renewal
• Thermodynamic recovery
• Summer dehumidification
• Freecooling
ELFOFresh2 [CPAN-U]:
Air renewal and purification unit, full fresh air
Configuration
• Cooling and heating operation
Accessories
• 1 x FES: Electronic filters
• 1 x CMMBX: Serial communication module to supervisor (Modbus)
Plant terminal unitsELFORoom2:
Water terminal unit, vertical and horizontal indoor installation, cased or uncased
Configuration
• OUTVOT: Vertical cased with LCD display, continuous modulation DC motor,
RS485 interface and built-in thermostat
Plant Elements
CLIVET SPA
Via Camp Lonc 25, Z.I. Villapaiera - 32032 Feltre (BL) - Italy
Tel. +39 0439 3131 - Fax +39 0439 313300 - info@clivet.it
CLIVET UK LTD (Sales)
4 Kingdom Close, Segensworth East - Fareham, Hampshire - PO15 5TJ
United Kingdom
Tel. +44 (0) 1489 572238 - Fax +44 (0) 1489 573033 - info@clivet-uk.co.uk
CLIVET AIRCON LTD (Service and Maintenance Division)
Units F5&F6 Railway Triangle Ind Est, Walton Road - Portsmouth, Hampshire - PO6 1TG
United Kingdom
Tel. +44 (0) 2392 381235 - Fax. +44 (0) 2392 381243 - info@clivetaircon.co.uk
CLIVET ESPAÑA COMERCIAL S.L. (Sales)
Calle Gurb, 17 1º 1ª - 08500 Vic, Barcelona - España
Tel. +34 93 8606248 - Fax +34 93 8855392 - info@clivetcomercial.com
CLIVET ESPAÑA S.A.U. (Service and Maintenance Division)
Calle Real de Burgos Nº 12 - 28860 Paracuellos del Jarama, Madrid - España
Tel. +34 91 6658280 - Fax +34 91 6657806 - info@clivet.es
CLIVET GmbH
Hummelsbütteler Steindamm 84, 22851 Norderstedt - Germany
Tel. +49 (0) 40 32 59 57-0 - Fax +49 (0) 40 32 59 57-194 - info.de@clivet.com
CLIVET RUSSIA
Elektrozavodskaya st. 24, offi ce 509 - 107023, Moscow, Russia
Tel. +7 495 646 2009 - Fax +7 495 646 2009 - info.ru@clivet.com
CLIVET MIDEAST FZCO
Dubai Silicon Oasis (DSO), High Bay Complex, Ind Unit No. 3, PO BOX 342009,
Dubai, UAE
Tel. +9714 3208499 - Fax +9714 3208216 - info@clivet.ae
CLIVET AIRCONDITIONING SYSTEMS PRIVATE LIMITED
4BA, Gundecha Onclave, Kherani Road - Sakinaka, Andheri (East) - Mumbai 400 072
India
Tel. +91 22 6193 7000 - Fax +91 22 6193 7001 - info.in@clivet.com
www.clivetlive.com
CLIVET SPA
Via Camp Lonc 25, Z.I. Villapaiera - 32032 Feltre (BL) - Italy
Tel. + 39 0439 3131 - Fax + 39 0439 313300 - info@clivet.it
In over 25 years of working on the design, manufacturing and distribution of air conditioning and handling
systems, combining high effi ciency with minimal environmental impact, Clivet has developed solutions to
ensure sustainable comfort and the well-being of people and the environment.
Designing and developing year-round air conditioning solutions with innovative technologies are part of Clivet’s
DNA, which means the company has always been ready for the future.
In 2015 the new division Clivet Live is born. With its application Clivet Home, it off ers a wide range of solutions
for the residential sector.
For over 25 years, we have been off ering solutions to ensure sustainable comfort and the well-being of people and the environment
DF1
5E0
01G
B-0
1
Recommended