Printed in Canada June 6, 2013(#109499)
Standpipe Piezometer Instructions
For further information contact: Solinst Canada Ltd.Fax: +1 (905) 873-1992; (800) 516-9081 Tel: +1 (905) 873-2255; (800) 661-2023
35 Todd Road, Georgetown, Ontario Canada L7G 4R8Web Site: www.solinst.com E-mail: instruments@solinst.com
Model 601
Component List
• Piezometer Tip lengths: 6", 1', 2', 3' (15 cm, 30 cm, 60 cm, 90 cm)
To Complete an installation you will also need to source the following:
• Plain End 3/4" Sch. 40 PVC Extensions (0.804"ID x 1.050"OD) (as required to reach desired depth)
• Slip Couplings for Sch. 40 PVC Pipe (one required for each extension)
• 3/4" Sch. 40 PVC Slip Cap• Optional Reducer Couplings
(used to connect to other sizes of riser pipe)
Operating PrinciplesStandpipe Piezometers are designed for placement within a drilled hole to provide a filtered inlet point. Piezometers can also be manually pushed into suitable sediment, such as very loose sands at the base of a borehole, a stream, or into very loose tailings pond sediments.
After the Standpipe Piezometer is installed to depth, ground-water enters through the porous filter and into the riser pipe, allowing water level monitoring, metals sampling, permeability measurements, slope stability tests, etc. The 60-micron filter in the 601 Piezometer is also ideal for air sparging and metals sampling.
Installation1. Ensure that all components are clean prior to use.2. Push the first PVC extension into the slip coupling
connected to the Piezometer Tip.3. Add couplings and extensions until the desired length is
reached, and install the Piezometer downhole. 4. After the Piezometer Tip and riser pipe are installed to
depth, the installation can be completed by backfilling sand around the filtered Piezometer Tip and finished with sand, gravel or bentonite to the surface, depending on your application. Finish the installation with a slip cap on the top of the final PVC extension.
Note: Avoid attempting to pull Model 601 Piezometers out of the soil after placement, since they are held together by friction fit only.
3/4" Sch. 40 PVC ExtensionPorous HDPE (Vyon) Filter
PVC Body Slip Coupling
Typical Standpipe Piezometer Installations
Bentonite Grout
Sand/Gravel BackfillBentonite
Seal
Sand Filter
3/4" Sch. 40 PVC (Riser Pipe) Extensions