View
238
Download
5
Category
Preview:
Citation preview
Drawing Description Drawing No.
Drawing Register PP 001 - 006
Introduction Series 000StoPoren Panel Cladding System StoPoren Plaster System PP 007
StoPoren Panel Cladding System StoPoren Plaster System PP 008
StoPoren Panel Cladding System StoPoren Panel Information PP 009
StoPoren Panel Cladding System StoPoren Panel layout PP 010
Panel Layout Series 100StoPoren Panel Cladding System Cavity Batten Setout (600 ctrs) - Isometric PP 100
StoPoren Panel Cladding System Cavity Batten Setout (400 ctrs) - Isometric PP 101
StoPoren Panel Cladding System Cavity Batten Setout Steel Frame/Thermal Break (600 ctrs) PP 102
StoPoren Panel Cladding System Cavity Batten Setout (300 & 600 ctrs) Elevation PP 103
Foundation Series 200StoPoren Panel Cladding System Foundation Slab-on-ground PP 200
StoPoren Panel Cladding System Insulated Slab-on-Ground PP 201
StoPoren Panel Cladding System Rebated Slab-on-Ground - Plaster Finish PP 202
StoPoren Panel Cladding System ESP Block Foundation Detail PP 203
StoPoren Panel Cladding System Conc.Block Foundation Edge Detail PP 204
StoPoren Panel Cladding System Solid Conc.Foundation Edge Detail PP 205
StoPoren Panel Cladding System Conc.Continuous Perimeter Found.Wall PP 206
StoPoren Panel Cladding System Timber Pile/Subfloor Ventilation (Parallel Wall) PP 207
StoPoren Panel Cladding System Timber Pile/Subfloor Ventilation (Right Angled Wall) PP 208
StoPoren Panel Cladding System Timber Subfloor with Jack Studs PP 209
StoPoren Panel Cladding System Masonry Conc.Block in-ground Wall PP 210
StoPoren Panel Cladding System Masonry Conc.Block Inter-Storey Drained Junction PP 211
StoPoren Panel Cladding System Ribraft Floor System / Edge Detail PP 212
StoPoren Panel Cladding System Maxraft Floor System / Edge Detail PP 213
Walls Series 300StoPoren Panel Cladding System Poren Panel layout PP 300
StoPoren Panel Cladding System Cross Section PP 301
StoPoren Panel Cladding System External Corner PP 302
StoPoren Panel Cladding System Internal Corner PP 303
StoPoren Panel Cladding System Vertical Control Joint PP 304
StoPoren Panel Cladding System Horizontal inter-storey Control Joint - Opt 1 PP 305
StoPoren Panel Cladding System Horizontal inter-storey Control Joint - Opt 2 PP 306
StoPoren Panel Cladding System Drained Joint at Third Storey PP 307
StoPoren Panel Cladding System Boxed Beam PP 308
StoPoren Panel Cladding System Post Detail PP 309
THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.
ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.
THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS
RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALL
WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
STO DRAWING REGISTER
PAGE 1 OF 6
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
DRAWING REGISTER
PP 001
2014
Drawing Description Drawing No.
Wall Penetrations & Fittings Series 350StoPoren Panel Cladding System Pipe Penetration Detail PP 350
StoPoren Panel Cladding System Light Fitting/Fixing Detail PP 351
StoPoren Panel Cladding System Tap Fiting/Fixing Detail PP 352
StoPoren Panel Cladding System Handrail Bracket/Fixing Detail PP 353
StoPoren Panel Cladding System Meterbox - Isometric PP 354
StoPoren Panel Cladding System Meterbox - Cross Section PP 355
StoPoren Panel Cladding System Downpipe Saddle Fixing & Wiring Details PP 356
StoPoren Panel Cladding System Fan Vent Detail PP 357
StoPoren Panel Cladding System Inter-Storey Junction with Poly Profile PP 358
StoPoren Panel Cladding System Joint at Third Storey with Poly profile PP 359
Joinery Series 400StoPoren Panel Cladding System Alu.Joinery - Head Detail - Stick on Jamb PP 400
StoPoren Panel Cladding System Alu.Joinery - Head Detail - Cavity Jamb PP 401
StoPoren Panel Cladding System Alu.Joinery - Sill Detail - Sto uPVC Stick on Sill PP 402
StoPoren Panel Cladding System Alu.Joinery - Sill Detail - Sto Cavity Sill PP 403
StoPoren Panel Cladding System Alu.Joinery - Jamb Detail - Sto uPVC Cavity Jamb PP 404
StoPoren Panel Cladding System Alu.Joinery - Jamb Detail - Sto uPVC Stick on Jamb PP 405
StoPoren Panel Cladding System Int.Cnr Alu.Window/Door Joinery - Jamb Detail PP 406
StoPoren Panel Cladding System Entry Door Threshold Detail PP 407
StoPoren Panel Cladding System Entry Door/Deck Threshold Detail PP 408
StoPoren Panel Cladding System Bifold Door/Threshold Detail PP 409
StoPoren Panel Cladding System Level Entry Threshold Detail PP 410
StoPoren Panel Cladding System Garage Door - Timber Head Detail PP 411
StoPoren Panel Cladding System Garage Door - Timber Jamb Detail PP 412
StoPoren Panel Cladding System Garage Door - Plastered Head Detail PP 413
StoPoren Panel Cladding System Garage Door - Plastered Jamb Detail PP 414
Parapets, Balustrades, Decks Series 500StoPoren Panel Cladding System Parapet/Metal Flashing Detail PP 500
StoPoren Panel Cladding System Plastered Parapet/Balustrade Detail PP 501
StoPoren Panel Cladding System Parapet and/or Encl.Balustrade Wall Junction - Plan View PP 502
StoPoren Panel Cladding System Flexible Flashing Install - Isometric PP 503
StoPoren Panel Cladding System Metal Saddle Flashing & Cap Install - Isometric PP 504
StoPoren Panel Cladding System StoFlexyl Meshed Saddle Flashing Install - Isometric PP 505
StoPoren Panel Cladding System StoFlexyl Meshed Waterproofing Cap - Isometric PP 506
StoPoren Panel Cladding System Balustrade/Encl.Deck Detail PP 507
StoPoren Panel Cladding System Enclosed Deck Detail PP 508
StoPoren Panel Cladding System Cantilevered Slatted Deck PP 509
StoPoren Panel Cladding System Non Cantilevered Slatted Deck PP 510
StoPoren Panel Cladding System Timber Beam/Pergola Detail PP 511
StoPoren Panel Cladding System Parallel Deck Joist Bracket PP 512
StoPoren Panel Cladding System RWH/Scupper Opening PP 513
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.
ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.
THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS
RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALL
WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
PAGE 2 OF 6
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
DRAWING REGISTER
PP 002
2014
Drawing Description Drawing No.
Soffit Series 600StoPoren Panel Cladding System Flat Soffit/Wall Junction PP 600
StoPoren Panel Cladding System Raking Soffit/Wall Junction PP 601
StoPoren Panel Cladding System Face Fixed Fascia PP 602
StoPoren Panel Cladding System Raking Soffit PP 603
StoPoren Panel Cladding System Raking Soffit - Sto uPVC Control Joint PP 604
StoPoren Panel Cladding System Soffit to Cladding Detail PP 605
StoPoren Panel Cladding System Gutter/Wall Junction PP 606
StoPoren Panel Cladding System Soffit at Window/Door Head PP 607
Roof Series 700StoPoren Panel Cladding System Apron Flashing PP 700
StoPoren Panel Cladding System Parallel Apron Flashing PP 701
StoPoren Panel Cladding System Inter-storey Transverse (Apron) Roof/Stopend PP 702
StoPoren Panel Cladding System Inter-storey Deck or Roof/Stopend Flashing PP 703
StoPoren Panel Cladding System Inter-storey Roof Stop End Flashing - Plan View PP 704
StoPoren Panel Cladding System Roof Penetration/Gutter (Masonry Tile) PP 705
StoPoren Panel Cladding System Roof Parallel/Hidden Gutter PP 706
StoPoren Panel Cladding System Face Fixed Fascia/Barge PP 707
StoPoren Panel Cladding System Face Fixed Fascia/Membrane Roof PP 708
StoPoren Panel Cladding System Roof/Wall Ridge PP 709
StoPoren Panel Cladding System Framed Chimney PP 710
Dissimilar Material
Weatherboard Series 800StoPoren Panel Cladding System Ext.Corner Weatherboard/Sto Poren - Opt 1 PP 800
StoPoren Panel Cladding System Ext.Corner Weatherboard/Sto Poren - Opt 2 PP 800-1
StoPoren Panel Cladding System Ext.Corner Weatherboard/Sto Poren - Direct Fix PP 801
StoPoren Panel Cladding System Int.Corner Weatherboard/Sto Poren - Opt 1 PP 802
StoPoren Panel Cladding System Int.Corner Weatherboard/Sto Poren - Opt 2 PP 802-1
StoPoren Panel Cladding System Int.Corner Weatherboard/Sto Poren - Direct Fix PP 803
StoPoren Panel Cladding System Vertical Joint Weatherboard/Sto Poren - Opt 1 PP 804
StoPoren Panel Cladding System Vertical Joint Weatherboard/Sto Poren - Opt 2 PP 804-1
StoPoren Panel Cladding System Vertical Joint Weatherboard/Sto Poren - Opt 3 PP 804-2
StoPoren Panel Cladding System Horizontal Junction Weatherboard/Sto Poren PP 805
StoPoren Panel Cladding System Gable End Weatherboard/Sto Poren PP 806
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.
ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.
THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS
RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALL
WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
PAGE 3 OF 6
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
DRAWING REGISTER
PP 003
2014
Drawing Description Drawing No.
Continuation Dissimilar Material
Brick Series 810StoPoren Panel Cladding System External Corner Brick Veneer/Sto Poren PP 810
StoPoren Panel Cladding System Internal Corner Brick Veneer/Sto Poren - Opt 1 PP 811
StoPoren Panel Cladding System Internal Corner Brick Veneer/Sto Poren - Opt 2 PP 812
StoPoren Panel Cladding System Vertical Junction Brick Veneer/Sto Poren PP 813
StoPoren Panel Cladding System Horizontal Junction Brick Veneer/Sto Poren PP 814
Fibre Cement Sheet Series 820StoPoren Panel Cladding System External Corner FC Sheet/ Sto Poren PP 820
StoPoren Panel Cladding System Internal Corner FC Sheet/ Sto Poren - Opt 1 PP 821
StoPoren Panel Cladding System Internal Corner FC Sheet/ Sto Poren - Opt 2 PP 822
StoPoren Panel Cladding System FC Sheet - Framed Sub Floor Cladding PP 823
StoPoren Panel Cladding System FC Sheet Gable End PP 824
Concrete Block Series 830StoPoren Panel Cladding System External Corner Concrete Block/Sto Poren PP 830
StoPoren Panel Cladding System Internal Corner Concrete Block/Sto Poren PP 831
StoPoren Panel Cladding System Vertical Joint Concrete Block/Sto Poren PP 832
StoPoren Panel Cladding System Horizontal Junction Concrete Block/Sto Poren PP 833
Manufactured Stone - Schist & Natural Stone Series 840StoPoren Panel Cladding System Ext.Cnr Manuf.Stone/Sto Poren - Opt 1 PP 840
StoPoren Panel Cladding System Ext.Cnr Manuf.Stone/Sto Poren - Opt 2 PP 841
StoPoren Panel Cladding System Ext.Cnr Schist or Stone Veneer/Sto Poren PP 842
StoPoren Panel Cladding System Boxed Ext.Cnr Stone Veneer/Sto Poren PP 843
StoPoren Panel Cladding System Internal Cnr. Manuf.Stone/Sto Poren PP 844
StoPoren Panel Cladding System Internal Cnr. Schist or Stone Veneer/Sto Poren PP 845
StoPoren Panel Cladding System Vertical Junction Manuf.Stone/Sto Poren PP 846
StoPoren Panel Cladding System Vertical Junction Schist or StoneVeneer/Sto Poren PP 847
StoPoren Panel Cladding System Horiz.Junction Manuf.Stone/Sto Poren PP 848
StoPoren Panel Cladding System Horiz.Junction Schist or StoneVeneer/Sto Poren PP 849
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.
ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.
THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS
RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALL
WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
PAGE 4 OF 6
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
DRAWING REGISTER
PP 004
2014
Drawing Description Drawing No.
Continuation Dissimilar Material
Profile Metal Series 850StoPoren Panel Cladding System Ext.Cnr Horiz.Profiled Metal/Sto Poren PP 850StoPoren Panel Cladding System Int.Cnr Horiz.Profiled Metal/Sto Poren PP 851StoPoren Panel Cladding System Vertical Junction Horiz.Profiled Metal/Sto Poren PP 852StoPoren Panel Cladding System Horizontal Junction Horiz.Profiled Metal/Sto Poren PP 853StoPoren Panel Cladding System External Corner Vertical Profiled Metal/Sto Poren PP 854StoPoren Panel Cladding System Internal Corner Vertical Profiled Metal/Sto Poren PP 855StoPoren Panel Cladding System Horiz.Junction Vertical Profiled Metal/Sto Poren PP 856
StoTherm Panel EIFS Series 860StoPoren Panel Cladding System Ext.Cnr StoTherm/Sto Poren PP 860StoPoren Panel Cladding System Int.Cnr StoTherm/Sto Poren PP 861StoPoren Panel Cladding System Vertical Joint 50mm StoTherm/Sto Poren PP 862StoPoren Panel Cladding System Vertical Joint 80mm StoTherm/Sto Poren PP 863StoPoren Panel Cladding System Inter-Storey Junction StoTherm/Sto Poren PP 864StoPoren Panel Cladding System Inter-Storey Third Storey Inter-storey Junction PP 865
DISSIMILAR JOINERY Series 870TIMBER JOINERYStoPoren Panel Cladding System Timber Window Joinery - Head Detail PP 870StoPoren Panel Cladding System Timber Window Joinery - Sill Detail PP 871StoPoren Panel Cladding System Timber Window Joinery - Jamb Detail PP 872StoPoren Panel Cladding System Timber Door Joinery - Timber Floor/Threshold Detail PP 873StoPoren Panel Cladding System Timber Door Joinery - Concrete Floor/Threshold Detail PP 874NK PVCu JOINERYStoPoren Panel Cladding System NK PVCu - Head Detail PP 875StoPoren Panel Cladding System NK PVCu - Sill Detail PP 876StoPoren Panel Cladding System NK PVCu - Jamb Detail PP 877FLASHMAN JOINERY FLASHING SYSTEMStoPoren Panel Cladding System Flashman Head Flashing PP 878StoPoren Panel Cladding System Flashman Sill Flashing PP 879StoPoren Panel Cladding System Flashman Jamb Flashing PP 880HOMERIT PVC JOINERYStoPoren Panel Cladding System Homerit PVC Joinery - Head Detail PP 881StoPoren Panel Cladding System Homerit PVC Joinery - Sill Detail PP 882StoPoren Panel Cladding System Homerit PVC Joinery - Jamb Detail PP 883
MOULDINGS & SHAPESRefer to - www.accumen.co.nzLightweight exterior decorative moldings and shapes, including columns, architraves,cornices, window sills, fence caps, quoins that can be finished in Stolit K or MP spongecoloured finishing render.Note: Decorative mouldings require min. 10° PPope to top surface and a drip edge.
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE TO INCORPORATE STANDARD BUILDING PRACTICES.ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE ISRESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALLWATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
PAGE 5 OF 6
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
DRAWING REGISTER
PP 005
2014
Drawing Description Drawing No.
StoPoren Panel(40mm Cavity)Series 1000
StoPoren Panel Cladding System Introduction (40mm Cavity) PP 1000
StoPoren Panel Cladding System Information (40mm Cavity) PP 1001
StoPoren Panel Cladding System Cavity Spacer Setout (600 Ctrs) PP 1002
StoPoren Panel Cladding System Cavity Batten Setout (600 Ctrs) PP 1003
StoPoren Panel Cladding System Cavity Batten Setout (400 Ctrs) PP 1004
StoPoren Panel Cladding System Cavity Batten Setout (400 Ctrs) - Elevation PP 1005
StoPoren Panel Cladding System Rebated Slab-on-Ground - Cavity Spacer PP 1006
StoPoren Panel Cladding System Foundation Slab-on-Ground - Cavity Spacer PP 1007
StoPoren Panel Cladding System External Corner PP 1008
StoPoren Panel Cladding System Internal Corner PP 1009
StoPoren Panel Cladding System Vertical Control Joint PP 1010
StoPoren Panel Cladding System Horizontal Inter-Storey Joint PP 1011
StoPoren Panel Cladding System Horizontal Inter-Storey Control Joint PP 1012
StoPoren Panel Cladding System Drained Joint at Third Storey PP 1013
StoPoren Panel Cladding System Meterbox Detail PP 1014
StoPoren Panel Cladding System Alu.Window Joinery - Head Detail PP 1015
StoPoren Panel Cladding System Alu.Window Joinery - Sill Detail PP 1016
StoPoren Panel Cladding System Alu.Window Joinery - Jamb Detail PP 1017
StoPoren Panel Cladding System Parapet Detail - Metal Cap PP 1018
StoPoren Panel Cladding System Parapet Detail - Plastered Finish PP 1019
StoPoren Panel Cladding System Parapet and/or Encl.Balustrade to Wall - Plan PP 1020
StoPoren Panel Cladding System Balustrade/Enclosed Deck Detail PP 1021
StoPoren Panel Cladding System Flexible Flashing Install PP 1022
StoPoren Panel Cladding System Metal Saddle Flashing PP 1023
StoPoren Panel Cladding System StoFlexyl Meshed Saddle Flashing PP 1024
StoPoren Panel Cladding System Raking Soffit/Wall Junction PP 1025
StoPoren Panel Cladding System Flat Soffit/Wall Junction PP 1026
STO DRAWING REGISTER
THESE DETAILS ARE ISSUED AS A GUIDE TO INCORPORATE STANDARD BUILDING PRACTICES.
ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.
THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS
RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INSTALLED INCLUDING ALL
WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
PAGE 6 OF 6
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
DRAWING REGISTER
PP 006
2014
STOPOREN PANEL CLADDING SYSTEM with Stoarmat Miral Plaster System
THE STOPOREN PANEL CLADDING SYSTEM HAS BEEN APPRAISED AS AN EXTERNAL WALL CLADDING SYSTEM FORBUILDINGS WITHIN THE FOLLOWING SCOPE:• THE SCOPE LIMITATIONS OF NZBC ACCEPTABLE SOLUTION E2/AS1, PARAGRAPH 1.1; AND,• CONSTRUCTED WITH TIMBER FRAMING COMPLYING WITH THE NZBC; AND,• WITH A RISK SCORE OF 0-20, CALCULATED IN ACCORDANCE WITH NZBC ACCEPTABLE SOLUTION E2/AS1, TABLE 2;
AND,• SITUATED IN NZS 3604 WIND ZONES UP TO, AND INCLUDING ‘EXTRA HIGH’.
THE STOPOREN PANEL CLADDING SYSTEM HAS ALSO BEEN APPRAISED FOR WEATHERTIGHTNESS AND STRUCTURALWIND LOADING WHEN USED AS AN EXTERNAL WALL CLADDING SYSTEM FOR BUILDINGS WITHIN THE FOLLOWING SCOPE:• THE SCOPE LIMITATIONS OF NZBC ACCEPTABLE SOLUTION E2/AS1, PARAGRAPH 1.1; AND,• CONSTRUCTED WITH TIMBER OR STEEL FRAMING COMPLYING WITH THE NZBC; AND,• SITUATED IN SPECIFIC DESIGN WIND PRESSURES UP TO A MAXIMUM DESIGN DIFFERENTIAL ULTIMATE LIMIT STATE
(ULS) OF 2.5 KPA.
STOARMAT MIRAL PLASTER SYSTEM Can also be used for additional strength & reinforcement
INCORPORATING:1. S-PROTECT WS 205 SEALER TO SEAL POREN PANELS2. STOPOREN PLASTER 25kg BAG3. STOARMAT MESHED REINFORCEMENT COAT4. STOLIT K : 1.0mm, 1.5mm, 2.0mm & 3.0mm COLOURED FINISHING RENDER MP : MP COLOURED FINE SPONGE FINISHING RENDER MP NATURAL COLOURED FINE SAND FINISHING RENDER MILANO SMOOTH COLOURED FINISHING RENDER5. STOCOLOR : MAXICRYL MATT FACADE PAINT 15lt PAIL
: LASTIC SATIN FACADE PAINT 15lt PAIL : LOTUSAN MINERAL RESIN PAINT 15lt PAIL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
STOPOREN PLASTER SYSTEM
PP 007
2014
STOPOREN PANEL CLADDING SYSTEM with Stoarmat Miral Plaster System
THE STOPOREN PANEL CLADDING SYSTEM HAS BEEN APPRAISED AS AN EXTERNAL WALL CLADDING SYSTEM FORBUILDINGS WITHIN THE FOLLOWING SCOPE:• THE SCOPE LIMITATIONS OF NZBC ACCEPTABLE SOLUTION E2/AS1, PARAGRAPH 1.1; AND,• CONSTRUCTED WITH TIMBER FRAMING COMPLYING WITH THE NZBC; AND,• WITH A RISK SCORE OF 0-20, CALCULATED IN ACCORDANCE WITH NZBC ACCEPTABLE SOLUTION E2/AS1, TABLE 2;
AND,• SITUATED IN NZS 3604 WIND ZONES UP TO, AND INCLUDING ‘EXTRA HIGH’.
THE STOPOREN PANEL CLADDING SYSTEM HAS ALSO BEEN APPRAISED FOR WEATHERTIGHTNESS AND STRUCTURALWIND LOADING WHEN USED AS AN EXTERNAL WALL CLADDING SYSTEM FOR BUILDINGS WITHIN THE FOLLOWING SCOPE:• THE SCOPE LIMITATIONS OF NZBC ACCEPTABLE SOLUTION E2/AS1, PARAGRAPH 1.1; AND,• CONSTRUCTED WITH TIMBER OR STEEL FRAMING COMPLYING WITH THE NZBC; AND,• SITUATED IN SPECIFIC DESIGN WIND PRESSURES UP TO A MAXIMUM DESIGN DIFFERENTIAL ULTIMATE LIMIT STATE
(ULS) OF 2.5 KPA.
STOPOREN PLASTER SYSTEM
INCORPORATING:1. S-PROTECT WS 205 SEALER TO SEAL POREN PANELS2. STOPOREN PLASTER 25kg BAG3. STOPLEX W SEALER 10lt CONTAINER4. STOLIT K : 1.0mm, 1.5mm, 2.0mm & 3.0mm COLOURED FINISHING RENDER 25kg PAIL5. STOCOLOR : MAXICRYL MATT FACADE PAINT 15lt PAIL
: LASTIC SATIN FACADE PAINT 15lt PAIL : LOTUSAN MINERAL RESIN PAINT 15lt PAIL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
STOPOREN PLASTER SYSTEM
PP 008
2014
2200
2020
0mm
STE
EL
RE
INFO
RC
ING
CE
NTR
ES
25 55 SCALE NTS
POREN PANELAUTOCLAVED AERATED CONCRETEDENSITY 600kg/m³THERMAL RESISTANCE RV 0.30ON CAVITY CONSTRUCTION
POREN PANEL DIMENSIONS2200 x 600 x 50mmFREIGHT20 PANELS PER DOUBLE PALLET1.3m³ PER PALLET + PALLETAREA 1.32sqm EACHWEIGHT 42kg EACH
POREN 100mm FIXINGSCOUNTERSUNK MAX. 12mm
MAX 300mm FIXING CENTRES
FIXINGS MINIMUM 40mm FROMTHE HORIZONTAL EDGE
STO CAVITY BATTENVH POLYSTYRENE1200 x 50 x 20mm250 PER PACKET
600
150
300
150
600
BEVELED EDGE OF PANELFACES FRAMING
50
FIXINGS
FIXINGS
170 155165
200
200
200
200
200
160
200
200
200
200
200
STEEL REINFORCING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
POREN PANEL INFORMATION
PP 009
2014
SCALE 1:50
600
50
50
STAGGER
CORNERS
CUT TO SPAN
MINIMUM OF
TWO STUDS
FILL IN JOINERY SILL
AND HEAD PANELS
AFTER JAMB PANELS
FITTED
MEASURE VERTICAL HEIGHT AND CUT
FROM TWO PANEL ROWS TO AVOID
NARROW PANEL WIDTHS
POREN PANEL INSTALLATION
1. LEAVE PANEL IN PLASTIC WRAP AND COVER TO KEEP DRY BEFORE USING.
2. READ SPECIFICATIONS AND CHECK DRAWINGS, DETAILS, FRAMING, UNDERLAY, FLASHING TAPES, AND BLOCKING
IS SATISFACTORY.
3. INSTALL STO PVC FOOT TRAY AND JOINERY FLASHINGS AS PER STO DETAILS (BUILDER TO SUPPLY
ALUMINUM HEAD FLASHINGS
4. CHECK PANEL LAYOUT AND INSTALL PANEL HORIZONTALLY STARTING FROM FOUNDATION.
5. STAGGER VERTICAL PANEL JOINTS GENERALLY OFF STUDS IN STRETCHER BOND PATTERN.
PANELS SHOULD BRIDGE TWO (2) STUDS TO ENSURE THEY ARE SECURELY FIXED
6. GLUE OR MORTAR ALL VERTICAL AND HORIZONTAL JOINTS AND SECURE PANELS WITH
POREN FIXINGS AS PER STO DETAILS.
7. STAGGER EXTERNAL CORNERS PANELS AND BUTT OR STAGGER INTERNAL CORNERS.
8. MEASURE VERTICAL DISTANCES AND CUT FROM LAST TWO ROWS OF PANEL TO AVOID NARROW WIDTHS.
9. PRIME EXPOSED REINFORCING ON CUT PANEL AND BUTT TO ADJACENT PANEL WHERE POSSIBLE.
10. SEAL PANELS WITH S-PROTECT WS 205 AS WORK PROCEEDS TO KEEP PANELS DRY.
2200
GENERALLY BUTT JOIN
PANELS OFF STUDS
SAFE WORKING PRACTICE
1. HAVE SUFFICIENT PEOPLE TO LIFT OR POSITION PANEL ON SITE (MINIMUM TWO MAN LIFT)
2. WEAR PROTECTIVE CLOTHING, EYE AND EAR PROTECTION AND DUST MASK OR RESPIRATOR
WHEN CUTTING OR SANDING.
3. USE A CIRCULAR SAW FITTED WITH A DIAMOND BLADE AND HEPA VACUUM WHEN CUTTING PANEL.
4. CONTAIN CUTTING AREA TO MINIMIZE DUST AND WARN OTHER IN IMMEDIATE VICINITY- HEPA VACUUM UP RESIDUE.
5. PROVIDE SUITABLE ACCESS PLATFORMS, EQUIPMENT AND TOOLS TO CARRY OUT THE WORK.
6. MAINTAIN HEALTH AND SAFETY REGULATIONS AND FIRST AID EQUIPMENT IN ACCORDANCE WITH LEGISLATION.
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
POREN PANEL LAYOUT
PP 010
2014
SCALE 1:20
TIMBER FRAMING
TO NZS 3604
STOPOREN PLASTER SYSTEM
- S-PROTECT WS 205 SEALER
- POREN PLASTER
- MESH REINFORCEMENT
PLASTER
- STOPLEX W SEALER
- STOLIT COLOURED
FINISHING RENDER
- STOCOLOR PAINT
EXTRA CAVITY BATTENS
BETWEEN 600mm CTR FRAMING
FOR FLEXIBLE UNDERLAY TO
STOP INSULATION ENCROACHING
INTO CAVITY
50m
m m
in.
WALL UNDERLAY MEETING
REQUIREMENTS OF E2/AS1
DPC
NOTE: 600mm FRAMING
FIXINGS AT 300mm CENTRES GENERALLY ON FRAMING 150mm
FROM PANEL EDGE WITH ONE FIXING BETWEEN STUDS ON THE
BOTTOM PLATE ON FRAMING @ 600mm CTRS max.
REFER TO FOUNDATION DETAILS FOR SPECIFIC FIXING LAYOUT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
CAVITY BATTEN SETOUT (600ctrs) - ISOMETRIC
PP 100
2014
SCALE 1:20
NOTE: 400mm FRAMINGFIXINGS AT 300mm CENTRES GENERALLY ON STUDS 150mm
FROM PANEL EDGE AND 400mm CTRS ALONG BOTTOM PLATE
ON FRAMING @ 400mm CTRS max.
REFER TO FOUNDATION DETAILS FOR SPECIFIC FIXING LAYOUT
STOPOREN PLASTER SYSTEM
- S-PROTECT WS 205 SEALER
- POREN PLASTER
MESH COAT
- STOPLEX W SEALER
- STOLIT K COLOURED
FINISHING RENDER
- STOCOLOR PAINT
50
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
CAVITY BATTEN SETOUT (400ctrs) - ISOMETRIC
PP 101
2014
SCALE 1:20
NOTE: 600mm FRAMINGFIXINGS AT 300mm CENTRES ON FRAMING 150mm FROM PANEL EDGE WITH ONE
FIXING BETWEEN STUDS ON THE BOTTOM PLATE OVER FRAMING @ 600mm CTRS max.
REFER TO FOUNDATION DETAILS FOR SPECIFIC FIXING LAYOUT
STOPOREN PLASTER SYSTEM
- S-PROTECT WS 205 SEALER
- POREN PLASTER
MESH COAT
- STOPLEX W SEALER
- STOLIT K COLOURED
FINISHING RENDER
- STOCOLOR PAINT
STEEL FRAME CONSTRUCTION MUST BE SPECIFIC DESIGN MEETING
REQUIREMENTS OF NZBC.
FOR STEEL FRAMED BUILDINGS SITUATED IN NZS 3604 WIND ZONES UP TO
VERY HIGH STUDS ARE AT 600mm MAX.CTRS. FOR ALL OTHER DWELLINGS
STUDS ARE AT 400mm MAX.CTRS, DWANGS ARE REQUIRED AT 800mm
CTRS
PROVIDE THERMAL BREAK TO ALL STEEL MEMBERS OR BRANZ APPRAISED
PROPRIETARY RIGID AIR BARRIER/THERMAL BREAK
STO ADJUSTABLE FOOT TRAY
MIN. 50mm PAST BOTTOM PLATE
OR SUBFRAME. VENTILATION MIN
1000sq mm PER LINEAL METRE
POREN PANEL ADHESIVE
ON PANEL JOINTS
POREN PANEL
10mm THICK THERMAL BREAK
BATTENS ON STUDS &
DWANGS - UNDER WALL
UNDERLAY
STEEL STUD
EXTRA CAVITY BATTEN
BETWEEN FRAMING @ 600mm
ctrs FOR FLEXIBLE UNDERLAY.
WALL UNDERLAY MEETING
REQUIREMENTS OF E2/AS1
MIN. R VALUE 0.3 THERMAL
BREAK TO ALL STEEL FRAMING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
CAVITY BATTEN SETOUT STEEL FRAME/THERMAL BREAK (600CTRS)
PP 102
2014
DOOR
WINDOW
FOUNDATION
FRAMING STUDS 400mm CENTERS
N.T.S
SOFFIT PLATE
DOOR WINDOW
FOUNDATION
FRAMING STUDS 600mm CENTERS - WITH BATTENS @
300mm CTRS
NOTE: EXTRA CAVITY BATTEN REQUIRED BETWEEN STUDS
FOR FLEXIBLE UNDERLAY CONSTRUCTION on 600 FRAMING
SOFFIT PLATE
300
600
400
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
CAVITY BATTEN LAYOUT (400 & 600ctrs) ELEVATION
PP 103
2014
SCALE 1:5
6mm OVERHANG
RECOMMENDED TO
AVOID VARIANCES IN
FOUNDATION
TIMBER FRAMING
TO NZS 3604
DPC
INTERIOR LINING
50m
m
clad.
AS PER NZS 3604
6
STO PLASTER SYSTEM
ON FOUNDATION
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN - NOT SHOWNFOR CLARITY
DPM
INSULATION
AS PER NZBC
H1/AS1
100m
m M
IN
.
Sto P
laster
50m
m
Flexyl
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FOUNDATION SLAB-ON-GROUND
PP 200
2014
SCALE 1:5
TIMBER FRAMING
TO NZS 3604
DPC
225m
m M
IN
.
TO
U
NP
AV
ED
G
RO
UN
D LE
VE
L
150m
m M
IN
.
TO
P
AV
ED
G
L
AS PER NZS 3604
DPM
INSULATION AS
PER NZBC -
Clause H1
100m
m M
IN
.
Sto P
laster
50m
m
Clad.
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INSULATED SLAB-ON-GROUND
PP 201
2014
SCALE 1:5
TIMBER FRAMING
TO NZS 3604
DPC
STO PLASTER SYSTEM
INTERNAL LINING
DPM
AS PER NZS 3604
75mm
rebate
10
INSULATION TO EXTERIOR
WALLS
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN - NOT SHOWNFOR CLARITY
INSULATION AS
NZBC H1/AS1
100m
m M
IN
.
Sto P
laster
50m
m
flexyl
50m
m
Clad.
100m
m
to paving
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
REBATED SLAB-ON-GROUND - PLASTERED FINISH
PP 202
2014
SCALE 1:5
CONCRETE FOOTING AS
PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
DPM REQUIRED ON FOUNDATION
FOR POORLY DRAINED SITES
OTHERWISE TERMINATE AT
BOTTOM EXTERNAL CORNER OF
FOUNDATION
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
DPC
NOTE:INSTALL STOFLEXYL UNDER DPM AT TRANSITION IF REQUIRED FOR POORLY
DRAINED SITES.
STO uPVC VENTED BASE CAP -
5mm MIN.GAP
WALL UNDERLAY
STO 20mm VH CAVITY
BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
CAVITY SPACERS TO
SUIT FIXINGS
DPM
INSULATION AS PER
NZBC - Clause H1
STOFLEXYL WATERPROOFING
TO REBATE, CONTINUE TO 50mm
PAST STO PLASTER
TERMINATION POINT
100m
m
Sto P
laster
50m
m
Flexyl
50m
m
cladding
150m
m
TO
P
AV
ED
G
L
225m
m
TO
U
NP
AV
ED
G
RO
UN
D LE
VE
L
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EPS BLOCK FOUNDATION DETAIL
PP 203
2014
225m
m unpaved G
L
SCALE 1:5
CONCRETE FOOTING AS
PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN
NOTE:SHELL OF BLOCK CAN SUPPORT
BOTTOM PLATE WHEN SLAB IS
TIED TO FOUNDATION
50m
m
cladding
150m
m to paved
GL
INSULATION AS PER
NZBC - Clause H1
DPM
STO uPVC VENTED
BASE CAP
WALL UNDERLAY
STO 20mm VH CAVITY
BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
CAVITY SPACERS TO
SUIT FIXINGS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
CONC.BLOCK FOUNDATION EDGE DETAIL
PP 204
2014
SCALE 1:5
50m
m
cladding
150m
m to paved
225m
m unpaved G
L
INSULATION AS PER
NZBC - Clause H1
DPM
DPC
10mm INSULATION
IF REQUIRED
GL
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR SPECIFIC
ENGINEER DESIGN (SED)
Varies
refer to N
ZS
3604 or S
ED
WALL UNDERLAY
POREN PANEL FIXING
POREN PANEL
STO uPVC VENTED
BASE CAP
STO 20mm VH CAVITY
BATTENS
STOPOREN PLASTER
SYSTEM
CAVITY SPACERS TO
SUIT FIXINGS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
SOLID CONC.FOUNDATION EDGE DETAIL
PP 205
2014
SCALE 1:5
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
50
NOTE:1. CONTINUOUS PERIMETER FOUNDATION
WALL WITH VENTILATION OPENINGS
2. CLEARANCE BETWEEN CLADDING AND
ADJACENT GROUND - REFER NZS3604
SED - Specific Engineer Design
as per N
ZS
3604
or S
ED
as per N
ZS
3604
or S
ED
FGL
as per NZS3604
MA
X.H
EIG
HT
- N
ZS
3604 6.11.2
MIN
.H
EIG
HT
6.11.2
WALL UNDERLAY
STO 20mm VH CAVITY BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
CONC.CONTINOUS PERIMETER FOUND.WALL
PP 206
2014
MIN. H1.2 TREATED
FLOOR JOISTS
20
20
50
100mm DRAPE TO
DOUBLE-SIDED PERFORATED
FOIL INSULATION R = 0.9 -
REFER NZBC - Clause H1
2/NAIL LAMINATED FLOOR JOISTS
UNDER LOAD BEARING WALLS
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
WALL UNDERLAY
STO 20mm VH CAVITY BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
H4 TREATED BASEBOARDS WITH
20mm CONTINUOUS SUB FLOOR
VENTILATION GAP BETWEEN
H3.2 TREATED BEARER, H5
TREATED PILE - REFER NZS 3604
FOR TIMBER & PILE SETOUT
POREN PANEL FIXING
NOTE:FOR CLEARANCE BETWEEN
CLADDING AND ADJACENT GROUND
- REFER NZS3604
SCALE 1:5
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER PILE/SUBFLOOR VENTILATION (Parallel Wall)
PP 207
2014
50
100mm DRAPE TO
DOUBLE-SIDED PERFORATED
FOIL INSULATION R = 0.9 -
REFER NZBC - Clause H1
MIN. H1.2 TREATED
FLOOR JOISTS
FLOOR JOISTS UNDER LOAD
BEARING WALLS
20
20
H4 TREATED BASEBOARDS WITH
20mm CONTINUOUS SUB FLOOR
VENTILATION GAP BETWEEN
SELECTED FLOORING
TIMBER FRAMING
TO NZS 3604
WALL UNDERLAY
STO 20mm VH CAVITY BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
SCALE 1:5
POREN PANEL FIXING
NOTE:FOR CLEARANCE BETWEEN
CLADDING AND ADJACENT
GROUND - REFER NZS3604
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER PILE/SUBFLOOR VENTILATION (Right Angled Wall)
PP 208
2014
OVERHANG BOUNDARY JOIST
TO ALLOW CLADDING TO LAP
SUBFLOOR CLADDING
100mm DRAPE TO
DOUBLE-SIDED PERFORATED
FOIL INSULATION R = 0.9 -
REFER NZBC - Clause H1
JACK FRAMING IN AS PER
NZS3604 6.10.2
DPC
WALL UNDERLAY
STO 20mm VH CAVITY BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
NOTE:FOR CLEARANCE BETWEEN
CLADDING AND ADJACENT
GROUND - REFER NZS3604
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER SUBFLOOR WITH JACK STUDS
PP 209
2014
SCALE 1:10
SLAB-ON-GROUND FLOOR & CONC.MASONRY WALLS AS PER NZS
4210/4229/4230 & AND ENGINEERS DRAWINGS
ALLOW ADEQUATE TIME FOR BLOCK TO DRY/STABALISE BEFORE
PLASTERING NORMALLY FROM 4-8 WEEKS IN AVERAGE DRYING
CONDITIONS.
50m
m
SELECTED
INTERIOR LINING
CONCRETE FLOOR SLAB, FOOTING
& WALL TO SPECIFIC DESIGN
SELECTED INTERIOR
PLASTER/FINISH
FILTER FABRIC
SLOTTED DRAIN LAID
TO A FALL
WALL UNDERLAY
NOMINAL 20x45mm H3.1 TIMBER
CAVITY BATTENS
POREN PANEL FIXING
POREN PANEL
POREN PLASTER SYSTEM
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
NZBC COMPLIANT WATERPROOF
TANKING MEMBRANE
NOTE:FOR CLEARANCE BETWEEN
CLADDING AND ADJACENT
GROUND - REFER NZS3604:2011
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
MASONRY CONC.BLOCK IN-GROUND WALL
PP 210
2014
SCALE 1:2
STO FLEXYL WATERPROOF TOCONCRETE REBATE SURFACES ANDPLASTER INTO REBATE
STOARMAT MIRALPLASTER SYSTEM
TIMBER FRAMINGTO NZS 3604
DPC
NOTE:CUT SLOPE AT 15° OR CUTREBATE AND PLASTER 15°SLOPE IN.
WALL UNDERLAY
STO 20mm VH CAVITYBATTENS
STOPOREN PLASTERSYSTEM
POREN PANEL FIXING
POREN PANEL
STO uPVC VENTED BASECAP
5
REINFORCED CONCRETE BLOCKWALLS IN ACCORDANCE WITH NZS4230, 4229, 4218 & 4210
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PLANEL CLADDING SYSTEM
CONCRETE BLOCK INTER-STOREY DRAINED JUNCTION
PP 211
2014
SCALE 1:5
50m
m
cladding
150m
m to paved
225m
m unpaved G
L
DPC
GL
WALL UNDERLAY
POREN PANEL FIXING
POREN PANEL
STO uPVC VENTED
BASE CAP
STO 20mm VH CAVITY
BATTENS
STOPOREN PLASTER
SYSTEM
CAVITY SPACERS TO
SUIT FIXINGS
RIBRAFT POLYSTYRENE POD
INSTALLATION IN ACCORDANCE TO FIRTH
RIBRAFT CONSTRUCTION DETAILS
85
220
CONCRETE SLAB/REINFORCING
AS PER NZS 3604, SPECIFIC
DESIGN OR ENGINEER (SED)
Reinforcing not shown for clarity
300
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
RIBRAFT FLOOR SYSTEM / EDGE DETAIL
PP 212
2014
DPC
WALL UNDERLAY
POREN PANEL FIXING
POREN PANEL
STO uPVC VENTED BASE CAP
20mm DRAINED CAVITY
STOPOREN
PLASTER SYSTEM
CAVITY SPACERS TO
SUIT FIXINGS
1. CONCRETE SLAB/REINFORCING AS PER NZS 3604,
SPECIFIC DESIGN OR ENGINEER (SED)
Reinforcing not shown for clarity2. WHERE INSULATION OS BELOW GROUND, APPLY TWO
(2) COATS OF STOFLEXYL TO MAXRAFT INSULATION
BEFORE COMMENCING
3. 150mm MIN. CLEARANCE FROM SLAB LEVEL TO
EXTERIOR PAVING, 225mm MIN. CLEARANCE FROM
SLAB LEVEL TO UNPAVED GROUND TO E2/AS1
SOLID COMPACTION
800mm MIN.PAST EDGE
OF FOUNDATION100
100
50
250
50
10
450
STOMULTI SCREED MESHED
BASECOAT FINISHED IN 1.0mm FLOAT
or STOLIT K FINISHING RENDER,
PAINTED IN STOCOLOR MAXICRYL
SCALE 1:10
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
MAXRAFT FLOOR SYSTEM / EDGE DETAIL
PP 213
2014
NOTE: USE FULL PANELS WHERE POSSIBLE.
ALL PANELS CUTS SHALL BE CAREFULLY MADE TO ACHIEVE A TIGHT BUTT FIT.
ALL PANEL JOINTS MUST BE BONDED WITH POREN ADHESIVE MORTAR OR AAC 2 HOUR
CONSTRUCTION GLUE.
MECHANICALLY FIX ALL PANELS WITH POREN SCREW FIXINGS AT MAXIMUM 300mm CENTRES.
PRIME ANY EXPOSED STEEL REINFORCING ENDS AND BUTT JOIN WHERE POSSIBLE.
PANELS TO BE SUPPORTED BY MINIMUM TWO STUDS OR BLOCKING.
VERTICAL CONTROL JOINTS REQUIRED AT MAXIMUM 8m CENTERS, SEE STO DETAILS.
HORIZONTAL CONTROL JOINTS AT INTERSTOREY JUNCTION IF UNSEASONED JOISTS USED.
HORIZONTAL DRAINED JUNCTION REQUIRED AT THIRD STOREY OR 7 METERS
N.T.S
600
50
50
STAGGER
CORNERS
CUT TO SPAN
MINIMUM OF
TWO STUDS
FILL IN JOINERY SILL
AND HEAD PANELS
AFTER JAMB PANELS
FITTED
MEASURE VERTICAL HEIGHT AND CUT
FROM TWO PANEL ROWS TO AVOID
NARROW PANEL WIDTHS
2200
GENERALLY BUTT JOIN
PANELS OFF STUDS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
POREN PANEL LAYOUT
PP 300
2014
NOTE: STO POREN FIXINGS AT 300mm MAX.CTRS
ENSURE FIXINGS ARE COUNTERSUNK 5mm MIN.WHERE A RIGID UNDERLAY OR
BRACING IS USED.
COUNTERSINK STO POREN FIXINGS TO ACHIEVE 30mm MIN.FRAME PENETRATION UP
TO A MAX.DEPTH OF 12mm
SCALE 1:5
TIMBER FRAMING
AS PER NZS 3604
FLEXIBLE OR RIGID
UNDERLAY
STOTHERM 20mm
VH CAVITY BATTEN
STO POREN FIXING
STO POREN PANEL
STO POREN
PLASTER SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
CROSS SECTION
PP 301
2014
POREN MINERAL PANEL
ADHESIVE OR AAC 2 HR
CONSTRUCTION GLUE ON ALL
PANEL JOINTS
SCALE 1:2
TIMBER FRAMING
TO NZS 3604
WALL UNDERLAY
CONTINUOUS AROUND
CORNERS
STO PREMESHED
CORNER ANGLE
STOTHERM 20mm VH
CAVITY BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXTERNAL CORNER
PP 302
2014
SCALE: 1:2
POREN MINERAL PANEL
ADHESIVE OR AAC 2 HR
CONSTRUCTION GLUE ON ALL
PANEL JOINTS
WALL UNDERLAY CONTINUOUS
AROUND CORNERS
INTERNAL CORNERS ARE
DOUBLE LAPPED MESHED
STOTHERM 20mm VH
CAVITY BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTERNAL CORNER
PP 303
2014
SCALE: 1:2
10mm GAP IN PANEL
NOTE:ENSURE POREN PANELS ARE SUPPORTED BY A MIN.OF 2/STUDS. VERTICAL JOINTS
ARE REQUIRED AT 8.0M MAX.CTRS. SET STO CONTROL JOINT AND REMOVE TAB
CAREFULLY AS SOON AS THE JOINT IS SET TO AVOID CRACKS
INSTALL STO uPVC CONTROL JOINT WITH
MS SEALANT IN MESH COAT
300mm MAX.CTRS
STOTHERM 20mm VH
CAVITY BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL FIXING
POREN PANEL
BETWEEN STUDS AT
CONTROL JOINT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL CONTROL JOINT
PP 304
2014
SCALE: 1:2
A
NOTE: SEASONED (dry) TIMBER FLOOR JOIST DETAIL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO POREN
SYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZONTAL INTER-STOREY (on dry joists) CONTROL JOINT
PP 305
2014
SCALE: 1:2
A
INSTALL STO uPVC 12mm
CONTROL JOINT WITH MS
SEALANT IN MESH COAT
15
10m
m G
AP
POREN PANEL
STO THERM 20mm VH CAVITY
BATTENS
STOPOREN PLASTER
SYSTEM
WALL UNDERLAY - ENSURE
UNDERLAY RUNS CONTINUOUS
OVER JOINT
POREN PANEL
STO THERM 20mm VH CAVITY
BATTENS
STO POREN PLASTER
SYSTEM
NOTE: UNSEASONED TIMBER FLOOR JOIST DETAIL.
STO POREN FIXING
STO POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZONTAL INTER-STOREY CONTROL JOINT
PP 306
2014
STO THERM 20mm VH CAVITY
BATTEN
FLASHING TAPE OVER
STO uPVC VENTED
BASE CAP
ALLOW TO PLASTER BEHIND
THEN SEAL WITH MS SEALANT
or STO SEAL TAPE
1. AS REQUIRED TO LIMIT
CONTINUOUS CAVITY
CONSTRUCTION TO TWO
STOREYS OR MAX.7
METERS FLASHING BACK
AND FRONT COVER TO BE A
MINIMUM 35mm EXCLUDING
DRIP EDGES.
2. IN EXTRA HIGH WIND ZONE
INCREASE FLASHING
COVER TO 60mm MIN. AND
USE A RIGID UNDERLAY
SCALE: 1:2
MIN
.C
OV
ER
MIN
.C
OV
ER
35m
m
STO POREN PLASTER SYSTEM
POREN PANEL
WALL UNDERLAY - ENSURE
UNDERLAY RUNS CONTINUOUS
OVER JOINT
WALL UNDERLAY - ENSURE
UNDERLAY RUNS CONTINUOUS
OVER JOINT
5
35m
m
STO POREN FIXING
STO POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
DRAINED JOINT AT THIRD STOREY
PP 307
2014
SCALE 1:2
MIN. 35mm HIGH BACK
FLASHING
FIBRE CEMENT SOFFIT.
STOARMAT PLASTER FC SOFFIT
& uPVC STO CLIP ON TRAYS
STO THERM 20mm
VH CAVITY BATTEN
WALL UNDERLAY
FLASHING TAPE
ONTO WALL
UNDERLAY
5mm GAP 5mm GAP
STO uPVC VENTED
BASE CAP
STO PLASTER
SYSTEM
POREN PANEL
STO POREN FIXING
MIN. 35mm HIGH BACK FLASHING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
BOXED BEAM
PP 308
2014
POREN PANEL
10
25
POST ANCHOR
BRACKET
STO PLASTER
SYSTEM
STO THERM 20mm VH
CAVITY BATTEN
POREN FIXING
SCALE 1:5
STO PREMESHED
CORNER
STO PLASTER SYSTEM
POREN PANEL FIXING
H3.2 TIMBER POST
STO THERM 20mm VH
CAVITY BATTENS
POREN PANEL - 2 HOUR AAC
CONSTRUCTION GLUE AT ALL
PANEL JOINS
25mm HIGH CONCRETE
PLINTH
10mm GAP BETWEEN PANEL
AND CONCRETE - SLOPE
CONCRETE OUT
STO uPVC
VENTED BASE
CAP
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
POST DETAIL
PP 309
2014
100mm min.
SCALE 1:5
FLASHING TAPE
STAR CUT
CUT LINES
8/10mm SEALANT BEAD ON PEF ROD
BETWEEN PIPE AND PLASTER
PIPE OR OTHER PENETRATION
SLOPED DOWNWARDS
TIMBER
FRAMING TO
NZS3604
POREN PANEL
STO PLASTER
SYSTEM
STO THERM 20mm VH
CAVITY BATTEN
WALL UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
PIPE PENETRATION DETAIL
PP 350
2014
SCALE 1:2
NOTE: LIGHTS AND LIGHT WEIGHT FITTINGS CAN BE FIXED
USING MASONRY FIXINGS WITH 40mm MIN. EMBEDMENT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
LIGHT FITTING/FIXING DETAIL
PP 351
2014
SCALE 1:2
TAP FITTING ON EPDM
RUBBER WASHER
PROVIDE TIMBER
BLOCKING AT TAP
WALL UNDERLAY
STOTHERM 20mm VH
CAVITY BATTENS
STOPOREN PLASTER
SYSTEM
POREN PANEL
FLASHING TAPE
100mm ONTO UNDERLAY
25mm ONTO TAP CONNECTION
MS SEALANT
AROUND TAP
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TAP FITTING/FIXING DETAIL
PP 352
2014
SCALE 1:2
TIMBER PACKER AT FIXINGS
POINTS - SLOPED AT 5
DEGREES min. 50mm
CLEARANCE FROM CAVITY
BATTENS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HANDRAIL BRACKET/FIXING DETAIL
PP 353
2014
POLY WEDGE OR BATTENFULL WIDTH OF METER BOX
AT min. 10° SLOPE WITHFLASHING TAPE OVER.
EXTEND WEDGE 100mmPAST SIDE OF METER BOX
LEAVE min. 50mm GAP IN CAVITYBATTEN FOR DRAINAGE
STO JOINT SEALTAPE OR PEF ROD
STO THERM 20mm VH CAVITYBATTENS TO BE 8mm FROM
SIDES OF METERBOX
POREN PANEL
SCALE 1:10
FLEXIBLE FLASHING TAPE 50mmOUT OVER THE METERBOX
PERIMETER ALL AROUND AND100mm ONTO UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
METERBOX - ISOMETRIC
PP 354
2014
SCALE 1:2
WEDGE OR BATTENSLOPED AT 10° MIN.WITH
BOTTOM EDGEEXTENDING INTO CAVITY
88
INTERNAL LINING
TIMBER FRAMINGTO NZS3604
INTERNAL LINING
TIMBER FRAMINGTO NZS3604
MS SEALANT OVER STO JOINT SEALTAPE TO PERIMETER OF METERBOX
STO POREN PLASTERSYSTEM
STO THERM 20mm VH CAVITYBATTEN WITH 50mm GAP FROMHORIZONTAL SLOPED BATTEN
AT JUNCTION
8mm AIRSEAL ONPEF ROD BYBUILDER
8mm AIRSEAL ONPEF ROD BYBUILDER
FLASHING TAPE OVER SLOPEDPOLY WEDGE OR BATTEN ONTO
WALL UNDERLAY
PRIME PANEL EDGESSTOPLEX W SEALER
METERBOX FLASHING TAPED 50mmONTO BOX AND 100mm ONTO WALLUNDERLAY ALL ROUND
STO 6mm PRE MESHEDFINISHING EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
METERBOX - CROSS SECTION
PP 355
2014
SCALE 1:2
uPVC OR OTHER
DOWNPIPE -
SIZE REFER
NZBC E1 Table 5
STO THERM 20mm VH
CAVITY BATTENS
DOWNPIPE/CLIP -
SADDLE @ 1.2M
CTRS MAX.
MS SEALANT ALL AROUND
CABLE/WIRING
PVC CONDUIT SLEEVE INSTALLED
AT 5 DEGREES DOWNWARD
SLOPE TO MESH COAT
1. DOWNPIPE/CLIP - SADDLE DETAIL
2. WIRING PENETRATION DETAIL
NOTE: ENSURE THE AMOUNT OF PENETRATIONS THROUGH THE
SYSTEM IS KEPT TO A MINIMUM. THE WEATHERSEALING OF ALL WIRING,
ETC AS SHOWN, IS THE RESPONSIBILITY OF THE APPLICABLE TRADE
STOPOREN PLASTER
SYSTEM
STO THERM 20mm VH
CAVITY BATTENS
STO POREN PANEL
STOPOREN PLASTER
SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
DOWNPIPE SADDLE FIXING & WIRING DETAILS
PP 356
2014
SCALE 1:2
EXTRACTION PIPE SLOPEDOWNWARDS AT MINIMUM 5°
FAN
CO
VE
R
TIMBER BLOCKING ASREQUIRED
NOTE:LEAVE 40mm DRAINAGE GAP IN SEALANT AT BOTTOM OF FAN COVER.INSTALL FLASHING TAPE 100mm AROUND PIPE ONTO WALL UNDERLAY AND WRAP25mm ROUND PIPE.FOR FLEXIBLE PIPES, TAPE PIPE TO FAN COVER, APPLY STO JOINT SEAL, TAPEAROUND TAPE BEFORE PLACING IN HOLE. ALWAYS FINISH PLASTER BEFOREINSTALLING FAN COVER
TIMBER FRAMING ASPER NZS 3604
STO THERM 20mm VHCAVITY BATTENS
STO POREN PANEL
STOPOREN PLASTERSYSTEM
TIMBER BLOCKING ASREQUIRED
FLEXIBLE FLASHINGTAPE
MS SEALANT TO HEAD &SIDES
MS SEALANT/PEF RODAT PIPE JUNCTION (STOSEAL TAPE ON FLEXIBLEPIPES)
FLEXIBLE FLASHINGTAPE
STO uPVC 6mmFINISHING EDGE
STO uPVC 6mmFINISHING EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FAN VENT DETAIL
PP 357
2014
PREMESHEDARCHITECTURAL PROFILEOVER INTERSTOREY JOINTFIXED OVER MESH COAT
STOPOREN PLASTERSYSTEM
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
A: INTERSTOREYPANEL JOINT
CENTRED 1/3 WAYDOWN FROM TOP
OF JOIST
NOTE:1. VERTICAL CAVITY BATTENS AREINSTALLED WITH A 15mm GAP ATINTER-STOREY JOINT2. INSTALL STO uPVC 12mm CONTROL JOINT3. ONLY SUITABLE FOR 2 STOREY - REFERDRAWING SHEET PP359 FOR THIRD STOREY4. ENSURE THERE ARE NO FIXINGS INTOFLOOR JOIST
A15
WALL UNDERLAY - ENSUREUNDERLAY RUNSCONTINUOUS OVER JOINT
min.10°FALL
STO POREN PLASTERSYSTEM
5mm GAP
10°
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENPLASTER SYSTEM
STO POREN PANEL CLADDING SYSTEM
INTER-STOREY JUNCTION WITH POLY PROFILE
PP 358
2014
STO POREN PLASTERSYSTEM
SCALE 1:2
TIMBER FRAMINGTO NZS 3604
WALL UNDERLAY -ENSURE UNDERLAY RUNSCONTINUOUS OVER JOINT
STOPOREN PLASTERSYSTEM
1. AS REQUIRED TO LIMITCONTINUOUS CAVITYCONSTRUCTION TO TWOSTOREYS or 7 METERS.FLASHING BACK ANDFRONT COVER TO BE AMINIMUM 35mmEXCLUDING DRIP EDGES
2. IN EXTRA HIGH WINDZONES INCREASEFLASHING COVER TO60mm AND USE A RIGIDUNDERLAY
STO THERM 20mm VHDRAINED CAVITYSTO POREN PANEL
INTER-STOREYFLASHING15°MIN.SLOPEAND 5mmMIN.GAP
ADDITIONAL WALLUNDERLAY DRESSED
OVER FLASHING5
STO VENTED BASE CAP
ATTACH WITH EPSSUITABLE ADHESIVE -TOPSIDE ONLY
STO POREN PLASTERMESHED BASECOATBEHIND PROFILE
PREMESHEDARCHITECTURALPROFILE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
JOINT AT THIRD STOREY WITH POLY PROFILE
PP 359
2014
1. FLASHING TAPE SYSTEM TO BE INSTALLED AROUND JOINERYOPENINGS AS PER E2/AS1 DETAILS
2. STO UPVC CAVITY VENTED HEAD FLASHING CAN BE USEDWHERE A PLASTERED HEAD IS DETAILED - REFER DWG PP 401
3. IN EXTRA HIGH WIND ZONES INCREASE FLASHING COVER TO60mm MIN.AND USE A RIGID UNDERLAY
SCALE 1:2
TIMBER LINTEL ASPER NZS 3604
STO POREN PLASTERSYSTEM
STO THERM 20mm VHCAVITY BATTEN
WALL UNDERLAY
FLASHING TAPE ONTOWALL UNDERLAY
STO POREN PANEL
ALUMINIUM WINDOWHEAD FLASHING WITH 15°SLOPE AND 10mm COVERAT WINDOW HEAD
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED FORVERY HIGH AND EXTRAHIGH WIND ZONES
35m
m M
IN.
50m
m
ALUMINIUM WINDOWJOINERY
INTERIOR LINING
AIRSEAL ON PEFROD GAP
7.5-8mm APPROX
5
STO uPVC VENTEDBASE CAP
STO POREN PANELFIXING
HEAD FLASHING WITH 10mmSTOPENDS POSITIONED10mm PAST WINDOW JAMBS
STO STICK ON JAMBFLASHING FINISH AT HEADFLASHING WITH PUNCHEDPLASTER LEG CONTINUING30mm ABOVE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ALU.JOINERY - HEAD DETAIL - STICK ON JAMB
PP 400
2014
SCALE 1:2
TIMBER LINTEL ASPER NZS 3604
STO POREN PLASTERSYSTEM
STO THERM 20mm VHCAVITY BATTEN
WALL UNDERLAY
FLASHING TAPE ONTOWALL UNDERLAY
STO POREN PANEL
ALUMINIUM WINDOWHEAD FLASHING WITH 15°SLOPE AND 10mm COVERAT WINDOW HEAD
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED FORVERY HIGH AND EXTRAHIGH WIND ZONES
35m
m M
IN.
50m
m
ALUMINIUM WINDOWJOINERY
INTERIOR LINING
AIRSEAL ON PEFROD GAP
7.5-8mm APPROX
1. FLASHING TAPE SYSTEM TO BEINSTALLED AROUND JOINERYOPENINGS AS PER E2/AS1 DETAILS.
2. THE ALUMINUM WINDOW HEADFLASHING BUTTS INTO THE STOCAVITY JAMB TO PROVIDE STOPENDAFTER REMOVING THE JAMB TAB ANDFITTING TO JOINERY BEFORE FITTINGWINDOW HEAD FLASHING TIGHT ANDMS SEALANT THE JUNCTIONS - SEEDETAIL PP402
3. IN EXTRA HIGH WIND ZONESINCREASE FLASHING COVER TO 60mmMIN.AND USE A RIGID UNDERLAY
STO uPVC MESHEDDRIP EDGE
STO POREN PANELFIXING
5
STO uPVC VENTEDHEAD FLASHING
STO CAVITY JAMBFLASHING 30mm ABOVEHEAD FLASHING FLASHINGTO FORM STOPENDS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ALU.JOINERY - HEAD DETAIL - CAVITY JAMB
PP 401
2014
SCALE 1:2
NOTE: OPENINGS OVER 600mm REQUIRE JOINERY SUPPORT BAR USE STO uPVC STICK ON JOINERY FLASHING WITH WANZ JOINERY SUPPORT BAR
JOINERY SUPPORT MUST BE CUT 15mm SHORT OF JOINERY JAMBS TO ALLOW FOR STO uPVC FLASHINGS1. SEALANT IS APPLIED TO THE SILL AND JAMB FLASHINGS2. WINDOW HEADS ARE LEFT OPEN3. FLEXIBLE FLASHING TAPE SYSTEM TO BE INSTALLED AROUND JOINERY OPENINGS AS PER E2/AS1 DETAILS
WARNING: SOME BRANDS OF ALUMINIUM JOINERY HAVE DRAINAGE VENTS IN THE BOTTOM EDGE OF THE SILL FLANGE. ENSURE DRAINAGE VENTS REMAIN CLEAR.
JOINERY SUPPORT BARREQUIRE FOROPENINGS OVER 600mm
PROPRIETARYALUM.WINDOWJOINERY
MS SEALANT
STOPOREN PLASTERSYSTEM
STO POREN PANEL
TIMBER FRAMINGTO NZS 3604
AIRSEAL ON PEF ROD GAP7.5-8mm APPROX.
WALL UNDERLAY RETURNED INTOOPENINGS & FLASHING TAPE
CONTINUOUS ALONG SILL MIN 100mm UPJAMBS & 50mm ONTO FACE OF WALL
UNDERLAY
STOPOREN FIXING
STO THERM 20mm VHCAVITY BATTEN
STO uPVC STICK ON JOINERYFLASHING FLASHING ADHESIVE FIXTO PANEL AT min.15° SLOPE
STO PRE-MESHEDADJUSTABLE CORNER
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ALUMINIUM JOINERY - SILL DETAIL - OPT 1
PP 402
2014
NOTE: JOINERY SUPPORT BAR REQUIRED ON OPENINGS OVER 600mm.1.SEALANT IS APPLIED TO THE SILL AND JAMBS2.WINDOW HEADS ARE LEFT OPEN3.FLEXIBLE FLASHING TAPE SYSTEM TO BE INSTALLED AROUND JOINERY OPENINGS AS PER E2/AS1 DETAILS
WARNING: SOME BRANDS OF ALUMINIUM JOINERY HAVE DRAINAGE VENTS IN THE BOTTOM EDGE OF THE SILL FLANGE. ENSURE DRAINAGE VENTS REMAIN CLEAR.
SCALE 1:2
PROPRIETARYALUM.WINDOWJOINERY
MS SEALANT
STOPOREN PLASTERSYSTEM
STO POREN PANEL
TIMBER FRAMINGTO NZS 3604
AIRSEAL ON PEF ROD GAP7.5-8mm APPROX.
WALL UNDERLAY RETURNED INTOOPENINGS & FLASHING TAPE
CONTINUOUS ALONG SILL MIN 100mm UPJAMBS & 50mm ONTO FACE OF WALL
UNDERLAY
STOPOREN FIXING
STO THERM 20mm VHCAVITY BATTEN
STO uPVC FACE FIXED JAMB ANDSILL FLASHING ADHESIVE FIX TOPANEL AT 15° SLOPE
STO PRE-MESHEDANGLE
NOTE: ONLY SUITABLE FOR OPENINGS UNDER 600mmOR JOINERY WITHOUT JOINERY SUPPORT BARS
10 10mm MIN.COVER
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ALU.JOINERY - SILL DETAIL - STO CAVITY SILL
PP 403
2014
SCALE 1:2
23 - 25m
m G
AP
10mm
20m
m C
AV
IT
Y B
AT
TE
N
+/- 3-5m
m T
O A
LLO
W
FO
R F
LA
SH
IN
G T
AP
ES
AT
JO
IN
ER
Y
ALUMINIUM
WINDOW JOINERY
MS SEALANT TO JAMBS
6
H1.2 PACKER TO
SUPPORT JOINERY
LINE OF HEAD FLASHING
OVER WITH STOPEND
WALL UNDERLAY RETURNED INTO
RECESS WITH FLASHING TAPE
SYSTEM. FLASHING TAPE RETURNED
min 100mm UP JAMBS AS PER E2/AS1
STOPOREN PLASTER
SYSTEM
STO POREN PANEL
STOPOREN FIXING
STO THERM 20mm VH
CAVITY BATTEN
STO uPVC CAVITY JAMB
AND SILL FLASHING
STO PRE-MESHED
ANGLE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ALU.JOINERY - JAMB DETAIL - STO uPVC CAVITY JAMB
PP 404
2014
NOTE: INSTALL STOPOREN JOINERY FLASHING DURING POREN PANEL CONSTRUCTION
SCALE 1:2
23 - 25m
m G
AP
10mm
20m
m C
AV
IT
Y B
AT
TE
N
+/- 3-5m
m T
O A
LLO
W
FO
R F
LA
SH
IN
G T
AP
ES
AT
JO
IN
ER
Y
ALUMINIUM
WINDOW JOINERY
MS SEALANT TO JAMBS
6
H1.2 PACKER TO
SUPPORT JOINERY
LINE OF HEAD FLASHING
OVER WITH STOPEND
WALL UNDERLAY RETURNED INTO
RECESS WITH FLASHING TAPE
SYSTEM. FLASHING TAPE RETURNED
min 100mm UP JAMBS AS PER E2/AS1
STOPOREN PLASTER
SYSTEM
STO POREN PANEL
STOPOREN FIXING
STO THERM 20mm VH
CAVITY BATTEN
STO uPVC STICK ON JOINERY
FLASHING
STO PRE-MESHED
ANGLE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ALU.JOINERY - JAMB DETAIL - STO uPVC STICK ON JAMB
PP 405
2014
MS SEALANT TO JAMBS
SCALE 1:2
TIMBER FRAMING
TO NZS 3604
20
STO UPVC CAVITY JAMB AND
SILL FLASHING
APPLY WS 205 SEALER
BEFORE PLASTERING
STO POREN FIXING
STO THERM 20mm VH
CAVITY BATTEN
POREN PANEL
POREN PLASTER SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CNR ALU.WINDOW/DOOR JOINERY - JAMB DETAIL
PP 406
2014
SCALE 1:5
SILL SUPPORT BAR
REFER TO E2/AS1 FIG. 17 A,B,C & D INCLUDING SECTION 9.1.10 .
GROUND LEVELS 150mm MIN.FROM TOP OF FINISHED FLOOR COVERING TO
PAVED GROUND
100
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ENTRY DOOR THRESHOLD DETAIL
PP 407
2014
SCALE 1:5
REFER TO E2/AS1 FIG. 17 A,B,C & D INCLUDING SECTION 9.1.10
MIN.THRESHOLD 100mm FROM FLOOR TO FINISHED DECK
NOTE: ADJUST 35mm TO ALLOW FOR SELECTED TILES AS REQUIRED, UNDER
DOOR TRIM BY BUILDER
100
35
SELECTED FLOORING
TURN-UP FLASHING
TAPE 100mm MIN. AT
TRIMMER STUDS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ENTRY DOOR/DECK THRESHOLD DETAIL
PP408
2014
SCALE 1:5
WANZ SUPPORT BAR COMPLETE WITH
VENTILATION/DRAINAGE HOLES,
INSTALLED TO MANUFACTURERS
RECOMENDATIONS
100
8
REFER TO E2/AS1 FIG. 17 A,B,C & D INCLUDING SECTION 9.1.10 .
150mm MIN. FROM TOP OF FFL COVERING TO PAVED GROUND
LINE OF STO POREN
CLADDING SYSTEM BEYOND
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
BIFOLD DOOR/THRESHOLD DETAIL
PP 409
2014
SCALE 1:5
DRAINAGE CHANNEL
FALL ALONG LENGTH
TO OUTLET
100
NOTE
REFER TO E2/AS1 FIG. 17 A,B,C & D INCLUDING SECTION 9.1.10
150
12
12m
m M
AX
.
200mm MIN.
WANZ SUPPORT BAR WITH
VENTILATION/DRAINAGE HOLES
INSTALLED TO MANUFACTURERS
RECOMMENDATIONS
UNDER DOOR TRIM BY BUILDER
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
LEVEL ENTRY THRESHOLD DETAIL
PP 410
2014
SCALE 1:2
1. CHECK GARAGE DOOR SPECIFICATIONS FOR INTERNAL CORNER REQUIREMENTS\2. SEAL FLASHING FOR VERY HIGH or EXTRA HIGH
WIND ZONES3. IN EXTRA HIGH WIND ZONES INCREASE FLASHING
COVER TO 60mm MIN.AND USE A RIGID UNDERLAY
TIMBER LINTEL ASPER NZS 3604
10
5
WALL UNDERLAY
ADDITIONAL LAYER OFFLASHING TAPE LAPPED
OVER HEAD FLASHING
20mm DRAINED CAVITY
STO uPVC VENTED BASECAP
ALUMINIUM HEADFLASHING WITH 15°
SLOPE AND 10mm COVER
MIN. 5mm GAP REQUIRED
POREN PANEL
STO POREN PLASTERSYSTEM
STO POREN PANELFIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
GARAGE DOOR - TIMBER HEAD
PP 411
2014
SCALE 1:2
WALL UNDERLAY
CONTINUOUS
AROUND CORNERS
TIMBER FRAMING
TO NZS 3604
STO POREN PLASTER
SYSTEM
6
MS SEALANT ON
STO JOINT SEAL
TAPE OR PEF ROD
POREN PANEL
SELECTED GARAGE DOOR
GARAGE DOOR TRIM
10
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
GARAGE DOOR TIMBER JAMB
PP 412
2014
SCALE 1:2
5mm MIN.GAP
STO uPVC ADJUSTABLE
FOOT TRAY - BASE
STO uPVC ADJUSTABLE
FOOT TRAY - FRONT ORSTO VENTED BASED CAP
POREN PANEL
STOPOREN
PLASTER SYSTEM
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
GARAGE DOOR - PLASTER HEAD DETAIL
PP 413
2014
SCALE 1:2
STO POREN PLASTER
SYSTEM
STOTHERM 20mm VH
CAVITY BATTEN
POREN PANEL
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
GARAGE DOOR - PLASTER JAMB DETAIL
PP 414
2014
SCALE 1:5
CARRY MESH/PLASTERUP TO TOP EDGEWALL UNDERLAY CONTINUOUSOVER TOP OF WALL FRAME
POREN PANEL
STO POREN PLASTERSYSTEM
20mm DRAINEDCAVITY
PROVIDE SEPARATION (ROOFUNDERLAY) UNDER METAL
CAPPING AND 9mm MIN.H3 PLY -PACKED TO A FALL
PRE FINISHED METAL CAPPINGTO PARAPET WITH 5° MIN.FALL
Z Z
5°
REFER TABLE 7- E2/AS1
POREN FIXING
1. INSTALL METAL SADDLE FLASHING AT WALL JUNCTION2. ENSURE TOP IS TEMPORARILY WATERPROOFED BEFORE COMMENCING PLASTERING3. METAL CAPPING EXCLUDING DRIP EDGE MUST OVERLAP SHEET BY
50mm MIN.IN LOW, MED or HIGH WIND ZONE,70mm MIN.IN VERY HIGH,90mm MIN.IN EXTRA HIGH WIND ZONES
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
PARAPET/METAL FLASHING DETAIL
PP 500
2014
SCALE 1:5
WALL UNDERLAY CONTINUOUSOVER TOP OF WALL FRAME
POREN PANEL
STO POREN PLASTERSYSTEM
20mm DRAINEDCAVITY
POREN FIXING
NOTE:STO FLEXYL MESHED WATERPROOFING MEMBRANE HAS BEENTESTED BY BRANZ TO MEET THE REQUIREMENTS OF AS/NZS4858
WATERPROOF MEMBRANE AS REQUIRED BY E2/AS1
EXTRA HIGH WIND ZONES REQUIRE A RIGID UNDERLAY. FLASHINGMUST BE TAPED TO RIGID UNDERLAY
OVERLAY OF STO FLEXYL MEMBRANEUNDER MESH COAT TO TOP & SIDES,75mm MIN.DOWNTURN OVERLEVELITE BASE COAT
STO PREMESHED uPVC ADJUSTABLECORNERS
75
POREN CAP AT 10°OVERSEATS WALLS, GLUE TO
POREN WALL CLADDING
75
10°
H3.1 CAPPING PLATE CUT TO10° SLOPE WITH FLASHING
TAPE OR ROOFING UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
PLASTERED PARAPET/BALUSTRADE DETAIL
PP 501
2014
SCALE 1:5
100mm MIN.
BALUSTRADE WALL UNDERLAY
LAPPED AROUND CORNER
FLASHING TAPE IN CORNERS
100x50mm MIN.
DRAIN FORMED IN
CORNER
100mm MIN.
STO POREN PLASTER
SYSTEM
STOTHERM 20mm VH
CAVITY BATTEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
PARAPET and/or ENCL.BALUSTRADE WALL JUNCTION - PLAN
PP 502
2014
SCALE 1:5
WALL UNDERLAYWALL FRAMING
DRAIN FORMED INCORNERCAVITY BATTENS
H3.1 CAPPINGPLATE CUT AT 10°SLOPE
FLEXIBLE FLASHING TAPE DRESSEDUP AND SECURELY ADHERED TO WALLUNDERLAY AT REAR OF CAVITYCONTINUE FLASHING TAPE OR ROOFUNDERLAY OVER H3.1 CAPPING PLATE
NOTE: POREN PANEL CAP TO BE POSITIONEDUNDER WALL 10mm OFF FRAMING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FLEXIBLE FLASHING INSTALL - ISOMETRIC
PP 503
2014
2 LINES OF
SEALANT
1
0
0
m
m
M
I
N
.
5
0
m
m
M
I
N
.
50
mm
M
IN
.
A. SADDLE FLASHING B. PARAPET CAP
METAL PARAPET CAP
FLASHING
RIVET THROUGH TOP OF CAP TO
SADDLE FLASHING. MS SEALANT
TO RIVETS
EXTENT OF SADDLE FLASHING
8mm EXPANSION GAP BETWEEN
PARAPET CAP AND SADDLE
FLASHING - USE MS SEALANT
NOTE: SADDLE FLASHING INSTALLED AFTER CAVITY
SYSTEM. 50x50mm INTERNAL CNR FLASHING FROM
BEHIND SADDLE EXTENDED TO BOTTOM OF WALL
PANELS ON EACH BUILDING FACE
STO 20mm VH CAVITY
BATTENS
PLACE CAP FLASHING OVER
SADDLE FLASHING - REFER TO
E2/AS1 FIGURE 12 FOR CAP FIXING
DETAILS.
H3.1 CAPPING PLATE CUT TO A
FALL WITH FLASHING TAPE OR
ROOFING UNDERLAY
WALL UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENPANEL
STO POREN PANEL CLADDING SYSTEM
METAL SADDLE FLASHING & CAP INSTALL
PP 504
2014
SCALE 1:5
NOTE:APPLY STOFLEXYL MESHED WATERPROOFING OVER BASECOATSTOFLEXYL MESHED WATERPROOFING HAS BEEN TESTED BY BRANZ TO MEET THEREQUIREMENTS OF AS/NZS4858 FOR A WATERPROOFING MEMBRANE AS REQUIREDBY E2/AS1
OVERLAY OF STOFLEXYLMEMBRANE UNDER MESH COAT TOTOP & SIDES 75mm MIN.DOWNTURNOVER LEVELITE BASE COATLEVELLITE BASECOATPLASTER
STO 20mm VH CAVITYBATTEN
FLASHING TAPE ORROOF UNDERLAY OVERH3.1 CAPPING PLATEH3.1 TIMBER CAPPING PLATECUT TO A FALL - MIN.10°
75
WALL UNDERLAYWALL FRAMING
POREN PANEL CAP
WALL UNDERLAY
STO 20mm VH CAVITYBATTENS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
STOFLEXYL MESHED SADDLE FLASHING - ISOMETRIC
PP 505
2014
SCALE 1:5
NOTE:APPLY STOFLEXYL MESHED WATERPROOFING OVERBASECOATSTOFLEXYL MESHED WATERPROOFING HAS BEEN TESTED BYBRANZ TO MEET THE REQUIREMENTS OF AS/NZS4858 FOR AWATERPROOFING MEMBRANE AS REQUIRED BY E2/AS1
75E2/AS1 REQUIRES BALCONY &PARAPET WALLS TO BE OFFSETFROM MAIN WALL PLAIN TOALLOW FOR SADDLE FLASHINGS
BASECOAT PLASTER,STOPOREN CAP OVER H3.1TIMBER CAPPING PLATE
10° FALL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
STO FLEXYL MESHED WATERPROOFING CAP
PP 506
2014
SCALE 1:5
POREN PANELSTO POREN PLASTERSYSTEM
20mm DRAINEDCAVITY
10°
NOTE:
HANDRAIL REQUIRED WHERE BALUSTRADE IS UNDER 1000mm
10150
35
STO uPVC VENTEDBASE CAP
20mm MIN.ANGLE FILLET
FULLY SUPPORTEDMEMBRANE UPSTAND
10° MIN.FALL TO TOP OFPARAPET
POREN PANELSTO POREN PLASTER
SYSTEM
WALL UNDERLAY CONTINUOUSOVER TOP OF WALL FRAME
STOTHERM 20mm VHCAVITY BATTEN
H3.1 TIMBER CAPPING PLATE -CUT TO 10° SLOPE WITH
FLASHING TAPE OR ROOFINGUNDERLAY OVER
STO PREMESHED PVCADJUSTABLE CORNER ANGLESOVERLAY OF STO FLEXYLMEMBRANE UNDER MESHCOAT TO TOP & SIDES, 75mmMIN.DOWNTURN OVER BASECOAT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO POREN SYSTEM
STO POREN PANEL CLADDING SYSTEM
BALUSTRADE ENCLOSED DECK DETAIL
PP 507
2014
SCALE 1:5
NOTE: - 100mm MIN. FROM FLOOR LEVEL FOR ENCLOSED DECKS
- MIN.FALLS: 1:40 FOR DECKS, 1:30 FOR ROOFS & 1:100 FOR
GUTTERS
- ALLOW FOR TILES IF REQUIRED
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ENCLOSED DECK DETAIL
PP 508
2014
35
STOPOREN PLASTER SYSTEM
6mm STO uPVC FINISHING
EDGE, SEAL END PANEL WITH
S PROTECT WS 205
20mm DRAINED CAVITY
STO JOINT SEAL TAPE & MS
SEALANT TO TOP AND SIDES
LINE OF CANTILEVER JOIST -
SHOWN DASHED
SOLID BLOCKING
BETWEEN JOISTS
5mm MIN. GAP BETWEEN
STOPOREN PLASTER SYSTEM
AND SADDLE FLASHING
5
35
MIN
.C
OV
ER
12mm MAX.DRAINAGE
CONTINUOUS INTER-STOREY
FLASHING
LINE OF CLADDING BETWEEN
JOISTS - SHOWN DASHED,
CUT AROUND JOIST
NOTE:REFER E2/AS1 Fig.16 FOR FLASHING REQUIREMENTS. PROVIDE 6-8mm
WIDE SEALANT JOINT AT CLADDING/SADDLE FLASHING JUNCTION.
50mm MIN. SET DOWN FROM FLOOR OR THRESHOLD FOR
CANTILEVERED SLATTED DECKS
12
5
STOPOREN PLASTER SYSTEM
6mm STO uPVC FINISHING
EDGE, SEAL END PANEL WITH
S PROTECT WS 205
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
CANTILEVERED SLATTED DECK
PP 509
2014
SCALE 1:5
CAVITY SPACERS TO SUIT
12
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
50
DECKING
DECK JOIST
FLOORING
FLOOR JOIST
WALL UNDERLAY
STO 20mm VH CAVITY
BATTEN
POREN PANEL FIXING
STO POREN PANEL
STO POREN PLASTER
SYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
NON CANTILEVERED SLATTED DECK
PP 510
2014
SCALE 1:2
WALL UNDERLAY
20mm DRAINED CAVITY
STO POREN PLASTER SYSTEM
FLASHING TAPE 100mm ONTO WALL
UNDERLAY 25mm ONTO BRACKET
MS SEALANT ON STO
JOINT SEAL TAPE
GALVANIZED OR STAINLESS
STEEL L BRACKET ENGINEERED
FOR LOAD
LINE OF STO JOINT SEAL TAPE -
SHOWN DASHED
TIM
BE
R B
EA
M
NOTE: 'L' BRACKET ENGINEERED FOR LOAD. FLASHING TAPE TO
BUILDING UNDERLAY IN ACCORDANCE WITH E2/AS1 FIG. 68
POREN FIXING
12mm MIN.GAP
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER BEAM / PERGOLA DETAIL
PP 511
2014
SCALE 1:5
ENGINEERED TO SPECIFIC
STRUCTURAL REQUIREMENTS
GALVANIZED OR STAINLESS STEEL
'H' or 'U' BRACKET, SEAL BRACKET
WITH MS SEALANT OVER PEF ROD
TIMBER BEAM TO BE FIXED AFTER
PLASTERING COMPLETE
40
40mm GAP RECOMMENDED
(12mm MIN. GAP)
STO POREN PLASTER
SYSTEM
POREN PANEL
MS SEALANT OVER STO JOINT
SEAL TAPE BETWEEN POREN
PANEL AND BRACKET
FIXING CAPACITY AS PER
ENGINEER
POREN FIXING
STO POREN PLASTER
SYSTEM
POREN PANEL
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
PARALLEL DECK JOIST BRACKET
PP 512
2014
SCALE 1:5
EPDM WASHERS REQUIRED AROUND
FIXINGS AND PLATE TO PROVIDE
WATERTIGHTNESS
RWH HEAD FIXED DIRECTLY ABOVE &
BELOW SCUPPER PENETRATION
PRE FINISHED 0.55MM BMT
STEEL CUSTOM FOLDED AND
RIVETED RAIN WATER HEAD
STOPLEX W SEALER & MS
SEALANT AROUND
OPENING/RHW
MEMBRANE DRESSED OVER 50x50mm
ALU.ANGLE REBATED INTO SUBSTRATE
50mm LIP
SECTION A - A
SELECTED MEMBRANE FINISH
OVER H3 "C" FACED PLYWOOD
LAID TO 1:60MIN.FALL. GLUE &
SCREW TO TIMBER JOISTS, ALL
EDGES SUPPORTED ON TIMBER
20mm MIN.ANGLE FILLET
OUTLET THROUGH WALL
LINE OF MEMBRANE
LAPPED 50mm MIN.BEHIND
WRAP UNDER CLADDING
DEBRIS SCREEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
RWH/SCUPPER OPENING
PP 513
2014
SCALE 1:10
VARIES
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FLAT SOFFIT/WALL JUNCTION
PP 600
2014
SCALE 1:10
H3.1 PRE PRIMED &
PAINTED FASCIA BOARD
VARIES
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
RAKING SOFFIT/WALL JUNCTION
PP 601
2014
SCALE 1:10
NOTE:
REFER TO E2/AS1 TABLE 1 FOR RISK LEVELS. EAVE FLASHINGSARE REQUIRED WHEN FASCIA IS 100mm OR LESS FROM WALLCLADDING AND ROOF PITCH IS LESS THAN 10°
H3.1 PRE PRIMED &PAINTED FASCIA BOARD
PREFINISHED METALROOFING OVER ROOFUNDERLAY
PREFABRICATED TRUSSTOP CHORD
50mm COVER TO CLADDINGWITH STO JOINT SEAL TAPE ORMS SEALANT ON PEF ROD
PRE FINISHED METAL E2 EAVES FLASHING,LAP 1300-200mm MAX. UNDER ROOFCLADDING, TURN DOWN INTO GUTTER
50
BLOCKING TO CLOSE OFF CAVITYFROM ROOF SPACE
WALL UNDERLAY20mm DRAINED CAVITYPOREN PANELSTO POREN PLASTERSYSTEM
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FACE FIXED FASCIA
PP 602
2014
SCALE 1:5
SELECTED FIBRECEMENT SOFFIT LINING
35
PREFINISHED METALROOFING OVER ROOF
UNDERLAY
STO POREN PLASTERSYSTEM
WALL UNDERLAY
POREN PANEL20mm DRAINED CAVITY
50x35mm MIN.METALFLASHING6mm MAX.GAP WITH MSSEALANT
NOTE:
MAX.ANGLE OF SOFFIT RESTRICTEDTO BETWEEN 91°-115°
50
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
RAKING SOFFIT
PP 603
2014
SCALE 1:5
SELECTED FIBRECEMENT SOFFIT LINING
5035
PREFINISHED METAL ROOFINGOVER ROOF UNDERLAY
STOPOREN PLASTERSYSTEM
WALL UNDERLAY
POREN PANEL20mm DRAINED CAVITY
STO uPVC JONERYCONNECTORFINISH WITH MS SEALANT
NOTE:
MAX.ANGLE OF SOFFIT RESTRICTEDTO BETWEEN 91°-115°
6
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
RAKING SOFFIT - STO uPVC CONTROL JOINT
PP 604
2014
SCALE 1:2
STO uPVC VENTED
BASE CAP
5mm MIN.GAP
FLASHING TAPE OVER
35mm MIN.HIGH BACK
FLASHING
STO uPVC CLIP ON TRAY
POREN PANEL
STOPOREN
PLASTER SYSTEM
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
SOFFIT TO CLADDING DETAIL
PP 605
2014
FASCIA
BUILDING UNDERLAY/RAB
STO POREN PANEL SYSTEM
WITH STO uPVC FOOT TRAY
OR STO uPVC BASECAP
STO 20mm VH CAVITY
BATTEN
FLASHING TAPE OR
BUILDING UNDERLAY
OVER FLASHING
APRON FLASHING WITH TAPERED
STOPEND TO DIVERT WATER INTO
GUTTER. PANEL TO BE CAREFULLY
CUT OVER STOPEND, SEALED & MS
SEALANT JOINTED
APPLY MS SEALANT JOINT TO
FASCIA BOARD ON COMPLETION
STOP SPOUTING MIN.10mm
CLEAR OF FINISHED WALL
CLADDING
NOTE:BACK FLASHING IS REQUIRED BEHIND FACISA AND
PANEL JUNCTION 50mm MIN.COVER
SCALE 1:10
SOFFIT
50x50mm BACK FLASHING
BEHIND FASCIA & CLADDING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
GUTTER/WALL JUNCTION
PP 606
2014
SCALE 1:2
SELECTED ALUMINIUM
WINDOW/DOOR JOINERY
TIMBER LINTEL AS
PER NZS 3604
100mm MIN.TO FACE OF CLADDING
SELECTED FIBRE CEMENT
SOFFIT LINING
18x18mm TIMBER BEAD AT
SOFFIT, PAINTED
LINE OF POREN PANEL CLADDING
BEYOND - SHOWN DASHED
PROVIDE AIRSEAL ON PEF
ROD GAP 7.5-8mm APPROX.
WALL UNDERLAY DRESSED
INTO OPENING AS PER
E2/AS1 DETAIL
varies
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
SOFFIT AT WINDOW/DOOR HEAD
PP 607
2014
SCALE 1:5
ROOF
STRUCTURE
20mm DRAINED CAVITY
POREN PANEL
75
35
R
E
F
E
R
E
2
/A
S
1
T
A
B
L
E
7
5
m
m
G
A
P
M
A
X
.
F
O
R
N
O
T
C
H
E
D
T
U
R
N
-D
O
W
N
STO POREN PLASTER SYSTEM
STO VENTED ADJUSTABLE
FOOT TRAY
POREN FIXING
ROOF UNDERLAY
CONTINUOUS TO TOP OF
FLASHING
STOPEND TO RUN 10mm
MIN.PAST CLADDING
PRE FINISHED METAL
APRON FLASHING
PREFINISHED METAL
ROOFING OVER UNDERLAY
SELECTED ROOF WRAP
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
APRON FLASHING
PP 700
2014
SCALE 1:5
75
35
ROOF STRUCTURE
20mm DRAINED CAVITY
POREN PANEL
STO POREN PLASTER SYSTEM
WALL UNDERLAY LAPPED
OVER APRON FLASHING
UPSTAND
REFER E2/AS1 TABLE 7
PORENFIXING
STO uPVC VENTED
ADJUSTABLE FOOT TRAY
APRON FLASHING WITH TAPERED
STOPEND TO DIVERT WATER IN
GUTTER. CLADDING TO BE CAREFULLY
CUT OVER STOPEND & SEALED
NOTE: PROVIDE FLASHING STOPEND AT ROOF TO
GUTTER JUNCTION TO DIVERT WATER INTO THE
GUTTER - Refer Drawing PP606
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
PARALLEL APRON FLASHING
PP 701
2014
SCALE 1:5
20mm DRAINED CAVITY
POREN PANEL
75
35
R
E
F
E
R
E
2
/A
S
1
T
A
B
L
E
7
5
m
m
G
A
P
M
A
X
.
F
O
R
N
O
T
C
H
E
D
T
U
R
N
-D
O
W
N
STO POREN PLASTER SYSTEM
STO VENTED ADJUSTABLE
FOOT TRAY
CAVITY CLOSER
PRE FINISHED METAL
APRON FLASHING
PREFINISHED METAL ROOFING
OVER UNDERLAY
SELECTED ROOF WRAP
POREN FIXING
ROOF UNDERLAY
CONTINUOUS TO TOP OF
FLASHING
NOTE: CONTRACTOR TO FIT STOPEND FLASHING & HEMMED
FLASHING FOR FASCIAS 50mm BEHIND CLADDING, 50mm BEHIND
FASCIA. STO CONTRACTOR TO APPLY FINISHED SEALANT JOINT
BETWEEN FASCIA & PLASTER. UNDERLAY or FLASHING TAPE OVER
FLASHING UPSTAND.
PARAPETS - REFER 500 SERIES - PARAPET DETAILS
50mm MIN.FASCIA BACK
FLASHING - SHOWN DASHED
STOPEND
FLASHING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTERSTOREY TRANSVERSE (APRON) ROOF STOPEND
PP 702
2014
SCALE 1:5
STOP END 10mm PAST
FINISHED CLADDING
FASCIA 10mm SHORT OF
FINISHED CLADDING WITH MS
SEALANT JOINT
POREN PANEL
20mm DRAINED
CAVITY
STOPOREN PLASTER
SYSTEM
POREN FIXING
10
10
BACK FLASHING 50mm BEHIND
FASCIA & CLADDING
35
75
110
150
STO STICK ON CONNECTOR or MS
SEALANT JOINT ON PEF ROD
BETWEEN STOPEND AND CLADDING
ROOFING MEMBRANE OVER METAL
STOPEND. STOPEND TO EXTEND 10mm
MIN.PAST FINISHED WALL
ROOFING MEMBRANE 150mm
MIN.UPSTAND, 75mm
CLADDING COVER, CLADDING
35mm MIN. ROOF/DECK
110
35
75
150
1
0
I
F
M
E
M
B
R
A
N
E
I
F
R
O
O
F
F
L
A
S
H
I
N
G
C
L
A
D
D
I
N
G
R
O
O
F
/
D
E
C
K
NOTE: MEMBRANE ROOF NOT SHOWN ON
STOP END FOR CLARITY. STOP END
UNDER MEMBRANE OR IN CONJUNCTION
WITH ROOF APRON FLASHING
A = CAVITY & FINISHED CLADDING + 10mm
PRE FINISHED FABRICATED
STOP END
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO POREN SYSTEM
STO POREN PANEL CLADDING SYSTEM
INTER-STOREY DECK OR ROOF/STOPEND FLASHING
PP 703
2014
SCALE 1:5
10
FASCIA 10mm SHORT OF
CLADDING - MS SEALANT JOINT
FINISHED CLADDING & FASCIA
MS SEALANT ON PEF RODS
H3.1 PRE PRIMED & PAINTED
FASCIA/BARGE BOARD
PRE FINISHED METAL
FLASHING
FASCIA / CLADDING BACK
FLASHING 50mm MIN.COVER
0.55mm BMT PREFINISHED
METAL APRON FLASHING
STOPEND
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTER-STOREY ROOF STOPEND - PLAN VIEW
PP 704
2014
100mm MIN.
75m
m50
mm
20mm DRAINED CAVITYSTO POREN PANELSTO POREN PLASTERSYSTEM
STO POREN FIXING
DRESS WALLUNDERLAY OVER
GUTTER LINING
SELECTED GUTTER LINING CARRIEDOVER ANTI-PONDING BOARD AND UPABUTMENT FRAME ON NOG TO SUIT
GUTTER BOARD AT ABUTMENTON NOGS TO SUIT
ANTI-PONDING BOARDLAID TO A 5° MIN.FALL
ROOF UNDERLAY CARRIEDDOWN OVER GUTTER LINING
MASONRY ROOFING TILE
SCALE 1:5
STO uPVC ADJUSTABLEFOOT TRAY
MIN. LAP
MIN.DEEP
STOTHERM LAPOVER UPSTAND.
FINISH 50mmMIN.ABOVE
GUTTER LINING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO POREN SYSTEM
STO POREN PANEL CLADDING SYSTEM
ROOF PENETRATION/GUTTER (Masonry Tile) DETAIL
PP 705
2014
SCALE 1:5
80mm MIN.80mm MIN.
20m
m M
IN
.
110m
m
NOTE: WHERE GUTTER FINISHES WITHIN THE LENGTH OF THE WALL, STEP LOWER PART OF
GUTTER OUT TO 10mm PAST THE CLADDING LINE, WHILE MAINTAINING REQ.CLEARANCES, TO
ALLOW THE GUTTER TO FEED INTO THE LOWER EAVES GUTTER.
- REFER NZBC E2/AS1 Fig: 50 Incl.Section 8.1.6.2
35m
m G
AP
75m
m M
IN
.C
OV
ER
MIN
.T
OT
AL
20mm DRAINED CAVITY
POREN PANEL
STO POREN PLASTER
SYSTEM
ADDITIONAL LAYER OF
FLASHING TAPE LAPPED
OVER GUTTER UP STAND
PORENFIXING
PRE FINISHED METAL GUTTER
STO uPVC VENTED BASE CAP
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
PARALLEL ROOF/HIDDEN GUTTER
PP 706
2014
SCALE 1:5
50/90mm LAP REFER NZBC,
TABLE 7 E2/AS1
H3.1 PRE PRIMED & PAINTED
FASCIA/BARGE BOARD
PRE FINISHED METAL
FLASHING
WALL UNDERLAY
20mm DRAINED CAVITY
POREN PANEL
STO POREN
PLASTER SYSTEM
6mm
MAX.GAP
MS SEALANT ON PEF ROD
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FACE FIXED FASCIA/BARGE
PP 707
2014
SCALE 1:5
SELECTED MEMBRANE FINISH OVER H3 "C" FACED
PLYWOOD LAID TO 1:60MIN.FALL. GLUE & SCREW TO
TIMBER JOISTS, ALL EDGES SUPPORTED ON TIMBER
MIN.5mm RADIUS
TO PLYWOOD
TAKE BOTH LAYERS 6mm PAST
S/S ANGLE TO FORM DRIP EDGE
PREFINISHED METAL SPOUTING
AND BRACKETS
50/90mm LAP REFER NZBC,
TABLE 7 E2/AS1
H3.1 PRE PRIMED & PAINTED
FASCIA/BARGE BOARD
MS SEALANT ON PEF ROD
WALL UNDERLAY
20mm DRAINED CAVITY
TIMBER FRAMING
TO NZS3604
CONTINOUS BATTEN TO
CLOSE OFF CAVITY
FROM ROOF SPACE
POREN PANEL
STO POREN PLASTER
SYSTEM
POREN FIXING
50m
m
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FACE FIXED FASCIA/MEMBRANE ROOF
PP 708
2014
SCALE 1:5
ROOF
STRUCTURE
PRE FINISHED METAL
FLASHING, TURN DOWN TO
SUIT PROFILE
PRE FINISHED METAL
ROOFING OVER
SELECTED ROOF UNDERLAY
50/90mm LAP REFER NZBC,
TABLE 7 E2/AS1
PRE FINISHED METAL
FLASHING, FIXED AT SIDE
ONLY
WALL UNDERLAY
20mm DRAINED CAVITY
POREN PANEL
STO POREN PLASTER SUSTEM
MS SEALANT ON PEF ROD
R
E
F
E
R
E
2
/A
S
1
T
A
B
L
E
7
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
ROOF/WALL RIDGE
PP 709
2014
PENETRATION APRON FLASHINGHEM FOLD UNDER ROOFING
SEPARATE ROOFING SHEETOVER
MIN. UPSTAND 110mm
SIDE COVER= 2 CRESTS
SCALE 1:20FRAMED CHIMNEY
STOARMAT PLASTER SYSTEMWITH PREMESHED EXTERNAL CORNERS
H3.1 TIMBER CAVITY BATTENS
WALL UNDERLAY
FIBRE CEMENT SHEETWALL CLADDING
35mm GAP BETWEENCLADDING AND FLASHING
SET ONE CORNER OF UPSTANDHIGHER UP ROOF PLANE
TO PROVIDE CROSS FALL
250mm MIN.
110
35
130 - 200
130 - 200
COVER 130 - 200mm MAX.REFER TO E2/AS1 Table 7
110
NOTE:SUITABLE FOR RECTANGULAR PENETRATIONSUP TO 1200mm WIDE.ROOF PITCH MUST BE 10° or HIGHER - REFERTO E2/AS1 TABLE 9 or 17 FOR MAX.ROOFLENGTH ABOVE PENETRATIONS. BLOCKINGREQUIRED FOR PENETRATIONS OVER 200mm
UNDERLAY SEPARATORBETWEEN FLASHINGAND FRAMING. FRAMETO SUPPORT FLASHING
CAVITY CLOSER POSITIONEDTO GIVE 15mm MIN.DRIPEDGE TO CLADDING
7535
ROOF STRUCTURENZS 3604
Table 7 NZBC
LAP 250mm MIN.
PREFINISHED METAL ROOFINGOVER UNDERLAY
SELECTED ROOF WRAP
0.55mm BMT PREFINISHEDMETAL APRON FLASHING
STOARMAT PLASTER SYSTEMOVER 7.5 - 9mm FIBRE
CEMENT SHEET CLADDINGSTO CAVITY BATTEN
WALL UNDERLAY LAPSOVER FLASHING
CAVITY CLOSER POSITIONEDTO GIVE 15mm MIN.DRIP
EDGE TO CLADDING
STOARMAT PLASTER SYSTEMOVER 7.5 - 9mm FIBRECEMENT SHEET CLADDINGSTO CAVITY BATTEN
STO CLIP ON FINISHING EDGE
WALL UNDERLAY LAPSOVER FLASHING
STO uPVC CLIP ON FINISHINGEDGE
SCALE 1:10
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FRAMED CHIMNEY
PP 710
2014
SCALE 1:5
E2/AS1 COMPLIANT
FLASHING
5mm
50mm COVER
50m
m
STOPOREN PLASTER
SYSTEM
POREN PANEL
STOTHERM 20mm VH
CAVITY BATTEN
STO uPVC END CAP TO
PANEL/MS SEALANT OVER
PEF ROD
NOTE: IF A TIMBER SCRIBER REQUIRED
EXTEND FLASHING ACCORDINGLY
POREN FIXING
SELECTED HORIZONTAL
TIMBER WEATHERBOARDS
OVER 20mm DRAINED CAVITY
STO uPVC 6mm
FINISHING EDGE
WALL UNDERLAY CONTINUOUS
AROUND CORNER
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CORNER W'BOARD/STO POREN - OPT 1
PP 800
2014
H3.1 SCRIBER TO SUIT
WEATHERBOARD PROFILE
SELECTED HORIZONTAL TIMBER
WEATHERBOARDS OVER 20mm
DRAINED CAVITY
FLASHING TAPE APPLIED TO
UNDERLAY MIN. 75mm WIDE
WALL UNDERLAY CONTINUOUS
AROUND CORNER
CNR BOARDS TO SUIT. ON
PANEL USE 2hr AAC
CONSTRUCTION GLUE, FIX
50mm S/S POZI DRIVE SCREWS
SCALE 1:5
STOPOREN PLASTER
SYSTEM
STOTHERM 20mm VH
CAVITY BATTEN
STO POREN PANEL
POREN FIXING
MS SEALANT
STO uPVC
FINISHING EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CORNER WEATHERBOARD/STO POREN - OPT 2
PP 800-1
2014
SCALE 1:5
E2/AS1 COMPLIANT
FLASHING
5mm
50mm COVER
50m
m
STOPOREN PLASTER
SYSTEM
POREN PANEL
STOTHERM 20mm VH
CAVITY BATTEN
STO uPVC END CAP TO
PANEL - MS SEALANT
NOTE: IF A TIMBER SCRIBER REQUIRED
EXTEND FLASHING ACCORDINGLY
POREN FIXING
BUILDING UNDERLAY
CONTINUOUS AROUND CORNER
STO uPVC 6mm FINISHING
EDGE
SELECTED HORIZONTAL
TIMBER WEATHERBOARDS -
DIRECT FIXED
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CORNER WEATHERBOARD/STO POREN - DIRECT FIX
PP 801
2014
SCALE 1:2
50mm MIN.
COVER
50m
m M
IN
.
CO
VE
R
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CORNER WEATHERBOARD/STO POREN - OPT 1
PP 802
2014
SCALE 1:5
NOTE: IF A TIMBER SCRIBER REQUIRED
EXTEND FLASHING ACCORDINGLY
E2/AS1 COMPLIANT
FLASHING
STOPOREN PLASTER SYSTEM
POREN PANEL
STOTHERM 20mm VH CAVITY BATTEN
S PROTECT WS 205 SEAL TO
END OF PANEL - MS SEALANT
POREN FIXING
SELECTED HORIZONTAL
TIMBER WEATHERBOARDS
OVER 20mm DRAINED CAVITY
STO uPVC 6mm FINISHING
EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CORNER WEATHERBOARD/STO POREN - OPT 2
PP 802-1
2014
SCALE 1:5
NOTE: IF A TIMBER SCRIBER REQUIRED
EXTEND FLASHING ACCORDINGLY
FLASHING TAPE APPLIED TO
UNDERLAY MIN. 75mm WIDE
WALL UNDERLAY CONTINUOUS
AROUND CORNER
MS SEALANT ON STO JOINT SEAL
TAPE or PEF ROD 6mm GAP MIN.
SELECTED HORIZONTAL TIMBER
WEATHERBOARDS - DIRECT FIXED
E2/AS1 COMPLIANT FOLDED
METAL FLASHING
STOPOREN PLASTER
SYSTEM
POREN PANEL
STOTHERM 20mm VH
CAVITY BATTEN
S PROTECT WS 205 SEAL TO
END OF PANEL - MS SEALANT
POREN FIXING
STO uPVC 6mm FINISHING
EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CORNER WEATHERBOARD/STO POREN - DIRECT FIX
PP 803
2014
SCALE 1:2
50mm MIN. 50mm MIN.
WALL UNDERLAY
SELECTED HORIZONTAL TIMBER
WEATHERBOARDS OVER 20mm
DRAINED CAVITY
MS SEALANT ON STO JOINT SEAL
TAPE OR PEF ROD 6mm MIN.GAP
40x40mm PC ALUMINUM ANGLE
WITH MS SEALANT AT
WEATHERBOARD SEALANT
STOTHERM 20mm VH
CAVITY BATTEN
POREN PANEL
STOPOREN PLASTER SYSTEM
- STO uPVC END CAP
STO 6mm FINISHING EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL JOINT - WEATHERBOARD/STO POREN - OPT 1
PP 804
2014
SCALE 1:2
COVER
WALL UNDERLAY
SELECTED HORIZONTAL TIMBER
WEATHERBOARDS OVER 20mm DRAINED
CAVITY, SCRIBER TO SUIT PROFILE
MS SEALANT ON STO JOINT SEAL
TAPE OR PEF ROAD 6mm MIN.GAP
E2/AS1 COMPLIANT TOP HAT
METAL FLASHING
STO THERM 20mm VH
CAVITY BATTEN
POREN PANEL
STO POREN PLASTER SYSTEM WITH
6mm FINISHING EDGE. S PROTECT
WS 205 TO SEAL END PANEL
A
NOTE:A = CHECK WITH SHEET METAL FOLDER A
NARROW NECK MAY REQUIRE A WELDED
JOINT OR WIDER TOP HAT
COVER
50mm MIN. 50mm MIN.
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL JOINT - WEATHERBOARD/STO POREN - OPT 2
PP 804-1
2014
SCALE 1:2
MS SEALANT ON STO JOINT SEAL
TAPE OR PEF ROAD 6mm MIN.GAP
STO THERM 20mm VH
CAVITY BATTEN
POREN PANEL
STO POREN PLASTER
SYSTEM/STO uPVC PANEL
END CAP & STO 6mm
FINISHING EDGE
50mm MIN.
50mm MIN.
COVER COVER
WALL UNDERLAY CONTINUOUS
SELECTED HORIZONTAL TIMBER
WEATHERBOARDS OVER 20mm DRAINED
CAVITY, SCRIBER TO SUIT PROFILE
E2/AS1 COMPLIANT BACK
FLASHING 50mm MIN.COVER TO
CLADDING
6
H3.2 REBATED TIMBER DIVIDING
POST
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL JOINT - WEATHERBOARD/STO POREN - OPT 3
PP 804-2
2014
SCALE 1:2
35m
m M
IN
.
5
35m
m M
IN
.
BEVEL-BACK TIMBER
WEATHERBOARDS TO NZS 3617
OVER 20mm DRAINED CAVITY
FLASHING TAPE LAPPED OVER
HEAD FLASHING
E2/AS1 COMPLIANT FLASHING
MIN. 5mm GAP
REQUIRED
CO
VE
RC
OV
ER
CAVITY CLOSER POSITIONED
TO GIVE 15mm MIN.DRIP
EDGE TO CLADDING
MS SEALANT OR STO JOINT
SEAL TAPE AS REQUIRED TO
PLASTER/FLASHING
POREN PANEL
STOPOREN PLASTER SYSTEM WITH 6mm
PRE MESHED FINISHING EDGE. SEAL
PANEL END WITH S PROTECT WS 205
20mm DRAINED CAVITY
TIMBER FILLET TO SUIT
1. IN EXTRA HIGH WIND ZONES
INCREASE FLASHING COVER TO 60mm
MIN.AND USE A RIGID UNDERLAY
1. IN EXTRA HIGH WIND ZONES
INCREASE FLASHING COVER TO 60mm
MIN.AND USE A RIGID UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZONTAL JUNCTION WEATHERBOARD/STO POREN
PP 805
2014
SCALE 1:2
35m
m M
IN.
CO
VE
R35
mm
MIN
.C
OV
ER
POREN PANEL
STO POREN PLASTERSYSTEM WITH STO 6mmPREMESHED FINISHINGEDGE. SEAL END PANELWITH S PROTECT WS 205
20mm DRAINED CAVITY
POREN FIXING
BEVEL-BACKTIMBERWEATHERBOARDSOVER 20mmDRAINED CAVITY
FLASHING TAPELAPPED OVER HEADFLASHING
CAVITY CLOSERPOSITIONED TO GIVE15mm MIN.DRIP EDGETO CLADDING
RIGID AIR BARRIERTO GABLE END
H3.1 CONTINUOUSHORIZONTALTAPERED PACKERBEHIND CAVITYCLOSER TORESTRICT AIRFLOW
ALU.INTER-STOREYFLASHING,STOPEND, 15° SLOPE& 35mm MIN.COVERMS SEALANT TOPLASTER/FLASHING
1. IN EXTRA HIGH WINDZONES INCREASEFLASHING COVER TO60mm MIN.AND USE ARIGID UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
GABLE END - WEATHERBOARD/STO POREN
PP 806
2014
SCALE 1:2
6mm WIDE MS
SEALANT JOINT OVER
STO JOINT SEAL TAPE
OR PEF ROD
SELECTED 70 SERIES
CLAY BRICK VENEER
40mm MIN.CAVITY
10
STO 6mm
PREMESHED
FINISHING EDGE. STO
uPVC END CAP TO
PANEL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXTERNAL CORNER BRICK VENEER/STO POREN
PP 810
2014
SCALE 1:2
SELECTED 70 SERIES CLAY BRICK
VENEER 40mm MIN.CAVITY
WALL UNDERLAY CONTINUOUS
AROUND CORNERS
STO POREN PANEL
STOPOREN PLASTER SYSTEM WITH STO
6mm PREMESHED FINING EDGE & STO
uPVC END CAP TO PANEL
STO THERM 20mm VH
CAVITY BATTEN
TIMBER FRAMING
TO NZS 3604
E2/AS1 COMPLIANT FLASHING, HEM TO
BOTH ENDS
50m
m M
IN
.
CO
VE
RC
OV
ER
50m
m M
IN
.
6mm WIDE MS SEALANT OVER STO
JOINT SEAL OR PEF ROD
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CNR BRICK VENEER/STO POREN - OPT 1
PP 811
2014
SCALE 1:2
6mm WIDE MS SEALANT OVER
STO JOINT SEAL TAPE
SELECTED 70 SERIES CLAY BRICK
VENEER 40mm MIN.CAVITY
WALL UNDERLAY CONTINUOUS
AROUND CORNERS
STO THE5RM 20mm VH
CAVITY BATTEN
STO POREN PLASTER SYSTEM WITH
STO 6mm PREMESHED FINISHING EDGE
& S PROTECT WS 205 TO SEAL END OF
PANEL
POREN PANEL
TIMBER FRAMING
TO NZS 3604
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CNR BRICK VENEER/STO POREN - OPT 2
PP 812
2014
SCALE 1:2
SELECTED 70 SERIES CLAY BRICK
VENEER WITH 40mm MIN.CAVITY
50mm MIN. 51mm MIN.
COVER COVER
E2/AS1 COMPLIANT
BACK FLASHING
6mm WIDE MS SEALANT OVER
STO JOINT SEAL TAPE
STO THE5RM 20mm VH
CAVITY BATTEN
STO POREN PLASTER SYSTEM WITH STO
6mm PREMESHED FINISHING EDGE & STO
uPVC END CAP TO PANEL
POREN PANEL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL JUNCTION - BRICK VENEER/STO POREN
PP 813
2014
SCALE 1:2
20mm DRAINED CAVITY
STOPOREN PLASTERSYSTEM
SILL 15° SLOPE OVERHANG30-50mm. FINISH ENDS WITH
BRICK SILL OR SLIP
VENT EVERY THIRDPERPEND
BRICK TIES
20
10mm
GAP
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZ.JUNCTION - BRICK VENEER/STO POREN
PP 814
2014
SCALE 1:2
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CNR FC SHEET/STO POREN
PP 820
2014
SCALE 1:2
INSTALL FIBRE CEMENT SHEET AND SEAL BEFORE POREN PANEL CLADDING.
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTERNAL.CORNER F C SHEET/STO POREN - OPT 1
PP 821
2014
SCALE 1:2
STO POREN PLASTER
SYSTEM
STO THERM 20mm VH
CAVITY BATTEN
STO uPVC PRE MESHED FINISHING
EDGE & STO uPVC BASE END
MS SEALANT OVER STO JOINT
SEAL TAPE or PEF ROD
STOARMAT PLASTER SYSTEM/FIBRE
CEMENT SHEET OVER 20mm DRAINED
CAVITY/STO uPVC FINISHING EDGE
WALL UNDERLAY CONTINUOUS
AROUND CORNER
ALLOW TO INSTALL 50x50mm
BACK FLASHING
STO POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTERNAL.CORNER F C SHEET/STO POREN - OPT 2
PP 822
2014
TIMBER FRAMING
TO NZS 3604
INTERIOR LINING
FLOORING
DIRECT FIXED FIBRE
CEMENT SHEET
STOARMAT PLASTER SYSTEM
FRAMED SUBFLOOR
WALL/BASEMENT
NOTE: FRAMED SUBFLOOR WALL OR BASEMENT -
NOT SUITABLE AS A WALL CLADDING WHERE E2/AS1
RISK MATRIX IS ABOVE 6
50m
m
SCALE 1:5
STO uPVC VENTED
BASE CAP
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FC SHEET - FRAMED SUB FLOOR CLADDING
PP 823
2014
SCALE 1:2
STO POREN PANEL
STO POREN
PLASTER SYSTEM
20mm DRAINED
CAVITY
STOARMAT uPVC
CLIP ON FOOT
RIGID AIR BARRIER
TO GABLE END
SELECTED FIBRE
CEMENT SHEET TO
GABLE END -
STOARMAT
PLASTER SYSTEM
FLASHING TAPE
50mmMIN.ONTO
PANEL & UNDERLAY
H3.1 CONTINUOUS
HORIZONTAL
PACKER BEHIND
CAVITY CLOSER TO
RESTRICT AIRFLOW
25m
m
flash.
40m
m cover
cladding
35m
m
CO
VE
R
5mm MIN.GAP
STO uPVC 6mm
FINISHING EDGE
E2/AS1 COMPLIANT
METAL FLASHING
1. IN EXTRA HIGH WIND ZONES INCREASE
FLASHING COVER TO 60mm MIN.AND USE
A RIGID UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENPLASTER SYSTEM
STO POREN PANEL CLADDING SYSTEM
FIBRE CEMENT SHEET GABLE END
PP 824
2014
SCALE 1:2
POREN PANEL
STO POREN
PLASTER SYSTEM
20mm DRAINED
CAVITY
50m
m M
IN
.
CO
VE
R
USE POLY PACKER
TO FORM GAP, STO
uPVC CONTROL JOINT
WITH MS SEALANT IN
STOARMAT CLASSIC
MESH
E2/AS1 COMPLIANT
BACK FLASHING
CHASED INTO
CONC.BLOCK
DPC
10
20
6
S PROTECT WS 205
TO SEAL END PANEL
STO THERM 20mm
VH CAVITY BATTEN
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CNR CONC.BLOCK/STO POREN
PP 830
2014
SCALE 1:2
STO S - PROTECT COATING SYSTEM FOR CLEAR FINISHED CONCRETE BLOCK
POREN PANEL
STO POREN PLASTER SYSTEM
WITH STO 6mm PREMESHED
FINISHING EDGE & STO uPVC END
CAP TO PANEL
20mm DRAINED CAVITY
STOARMAT MIRAL PLASTER
SYSTEM ON SELECTED
CONCRETE BLOCK
E2/AS1 COMPLIANT BACK
FLASHING CHASED INTO
CONC.BLOCK
MS SEALANT OVER STO JOINT
SEAL TAPE OR PEF ROD
DPC
20m
m50m
m M
IN
.
POREN FIXING
STO THERM 20mm VH CAVITY
BATTEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTERNAL CORNER CONC.BLOCK/STO POREN
PP 831
2014
SCALE 1:2
COVER
POREN PANEL
STO POREN PLASTER
SYSTEM. SEL END PANEL
WITH S PROTECT WS 205
STOARMAT MIRAL PLASTER
SYSTEM ON SELECTED
CONCRETE BLOCK SERIES
E2/AS1 COMPLIANT BACK
FLASHING CHASED INTO
CONC.BLOCK
STO uPVC CONTROL JOINT
ALLOW 10mm GAP FILL WITH
MS SEALANT ON COMPLETION
10mm
DPC
50mm MIN. 20mm
POREN FIXING
STO THERM 20mm
VH CAVITY BATTEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL JOINT CONC.BLOCK/STO POEREN
PP 832
2014
SCALE 1:2
50m
m M
IN
.
6
m
m
G
A
P
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZONTAL JUNCTION CONC.BLOCK/STO POREN
PP 833
2014
SCALE 1:2
NOTE: FINISH STO POREN CLADDING SYSTEM
BEFORE INSTALLING STONE CLADDING
PROPRIETARY MANUF.STONE CLADDING
OVER ADHESIVE MORTAR ON 9mm
ETERPAN FIXED ACCORDING TO
VENTCLAD CONSTR.DETAILS
STO THERM 20mm VH
CAVITY BATTEN
SEAL END PANEL WITH S
PROTECT WS 205
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CORNER - MANUF.STONE/STO POREN - OPT 1
PP 840
2014
SCALE 1:2
STO PVC CORNER ANGLES
ON EXTERNAL CORNERS
MS SEALANT ON
PEF ROD
NOTE: FINISH STO POREN CLADDING SYSTEM
BEFORE INSTALLING STONE CLADDING
PROPRIETARY MANUF.STONE CLADDING
OVER ADHESIVE MORTAR ON 9mm
ETERPAN FIXED ACCORDING TO
VENTCLAD CONSTR.DETAILS
STO THERM 20mm VH
CAVITY BATTEN
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CORNER MANUF.STONE/STO POREN - OPT 2
PP 841
2014
SCALE 1:2
TIMBER FRAMING
TO NZS 3604
MS SEALANT ON
PEF ROD
PROPRIETARY SCHIST OR STONE VENEER
CLADDING OVER ADHESIVE MORTAR ON
9mm ETERPAN FIXED ACCORDING TO
VENTCLAD CONSTR.DETAILS
WALL UNDERLAY CONTINUOUS
AROUND CONERS,POLY
PROPYLENE FLASHING TAPE
APPLIED TO PROTECT WALL
UNDERLAY 75mm MIN.WIDE
NOTE: FINISH STO POREN CLADDING SYSTEM
BEFORE INSTALLING STONE CLADDING
POREN PANEL
20mm DRAINED
CAVITY
STO POREN
PLASTER SYSTEM
POREN FIXING
STO uPVC CORNER
ANGLE OVER FC
SHEET
STO THERM 20mm VH
CAVITY BATTEN
STOFLEXYL MORTAR
PANEL TO FC SHEET
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CORNER - SCHIST or STONE VENEER/STO POREN
PP 842
2014
SCALE 1:2
POREN PANEL BONDED WITH POREN MINERAL PANEL ADHESIVE OR AAC 2HR CONSTRUCTION GLUE
POREN FIXING
TIMBER FRAMING
TO NZS 3604
WALL UNDERLAY
CONTINUOUS AROUND
CORNERS
E2/AS1 COMPLIANT
BACK FLASHING
PROPRIETARY
STONE VENEER
CLADDING OVER
ADHESIVE MORTAR
ON 9mm ETERPAN
FIXED ACCORDING
TO VENTCLAD
CONSTR.DETAILS
STO PREMESHED
PVC CNR.ANGLES
ON ALL EXT.CNRS
STO THERM 20mm VH
CAVITY BATTEN
POREN PANEL
STO 6mm PREMESHED
FINISHING EDGE
SEAL END PANEL WITH S
PROTECT WS 205
MS SEALANT
OVER PEF ROD
STO PREMESHED
PVC CNR.ANGLES
ON ALL EXT.CNRS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
BOXED EXT.CORNER - STONE VENEER/STO POREN
PP 843
2014
SCALE 1:2
TIMBER FRAMING
TO NZS 3604
POREN PANEL
STOPOREN PLASTER
SYSTEM
20mm DRAINED CAVITY
DOUBLE STUD REQUIRED
E2/AS1COMPLIANT
CORNER FLASHING
8mm GAP, MS SEALANT JOINT
NOTE: INSTALL FC SHEET AND FINISH STO POREN
CLADDING SYSTEM BEFORE INSTALLING STONE
8
WALL UNDERLAY CONTINUOUS
AROUND CORNERS
MS SEALANT ON PEF ROD
PROPRIETARY MANUF.STONE CLADDING
OVER ADHESIVE MORTAR ON 9mm
ETERPAN FIXED ACCORDING TO
VENTCLAD CONSTR.DETAILS
STO 6mm PREMESHED FINISHING
EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTERNAL CORNER - MANUF.STONE/STO POREN
PP 844
2014
SCALE 1:2
TIMBER FRAMING
TO NZS 3604
POREN PANEL
STOPOREN PLASTER
SYSTEM
20mm DRAINED CAVITY
DOUBLE STUD REQUIRED
E2/AS1 COMPLIANT
CORNER FLASHING
8mm GAP, MS SEALANT JOINT
NOTE: INSTALL FC SHEET AND FINISH STO POREN
CLADDING SYSTEM BEFORE INSTALLING STONE
8
WALL UNDERLAY CONTINUOUS
AROUND CORNERS
MS SEALANT ON PEF ROD
STO 6mm PREMESHED
FINISHING EDGE
PROPRIETARY SCHIST OR STONE VENEER
CLADDING OVER ADHESIVE MORTAR ON
9mm ETERPAN FIXED ACCORDING TO
VENTCLAD CONSTR.DETAILS
STO THERM 20mm VH
CAVITY BATTEN
SEAL END PANEL WITH S
PROTECT WS 205
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CNR SCHIST or STONE VENEER/STO POREN
PP 845
2014
SCALE 1:2
50mm MIN. 50mm MIN.
COVER COVER
MS SEALANT ON PEF ROD
E2/AS1 COMPLIANT
BACK FLASHING
PROPRIETARY MANUF.STONE CLADDING
OVER ADHESIVE MORTAR ON 9mm
ETERPAN FIXED ACCORDING TO
VENTCLAD CONSTR.DETAILS
POREN PANEL
STOPOREN PLASTER
SYSTEM
STO 6mm PREMESHED
FINISHING EDGE
STO THERM 20mm
VH CAVITY BATTEN
STO uPVC END CAP
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL JUNCTION - MANUF.STONE/STO POREN
PP 846
2014
SCALE 1:2
MS SEALANT
E2/AS1 COMPLIANT BACK FLASHING
WITH 50mm MIN.CLADDING COVER
PROPRIETARY SCHIST OR STONE
VENEER CLADDING OVER ADHESIVE
MORTAR ON 9mm ETERPAN FIXED
ACCORDING TO VENTCLAD
CONSTR.DETAILS
MS SEALANT ON
PEF ROD
POREN PANEL
STOPOREN PLASTER
SYSTEM
STO 6mm PREMESHED
FINISHING EDGE
STO THERM 20mm
VH CAVITY BATTEN
STO uPVC END CAP
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERT.JUNCTION - SCHIST or STONE VENEER/STO POREN
PP 847
2014
SCALE 1:2
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZ.JUNCTION - MANUF.STONE/STO POREN
PP 848
2014
SCALE 1:2
PROPRIETARY SCHIST
OR STONE VENEER
CLADDING OVER
ADHESIVE MORTAR ON
9mm ETERPAN FIXED
ACCORDING TO
VENTCLAD
CONSTR.DETAILS
5
m
m
G
A
P
35
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZ.JUNCTION - SCHIST or STONE VENEER/STO POREN
PP 849
2014
SCALE 1:5
E2/AS1 COMPLIANTR
METAL FLASHING
10mm
100mm COVER
50m
m
STOPOREN PLASTER
SYSTEM
POREN PANEL
STOTHERM 20mm VH
CAVITY BATTEN
POREN FIXING
HORIZONTAL PROFILED
METAL WALL CLADDING
PROFILED FOAM CLOSURE
STRIP UNDER CLADDING
STO uPVC END CAP/MS
SEALANT
STO uPVC 6mm
FINISHING EDGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CORNER - HORIZ.PROFILED METAL/STO POREN
PP 850
2014
SCALE 1:2
FIXINGS IN ACCORDANCE WITH
E2/AS1
50m
m C
OV
ER
6m
m G
AP
10
PROFILED FOAM CLOSURE
STRIP UNDER CLADDING
DOUBLE STUD REQUIRED
HORIZONTAL PROFILED METAL WALL
CLADDING (SPECIFY TYPE, THICKNESS
& COATING)
E2/AS1 COMPLIANT FLASHING
REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS
HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY
VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY
STO POREN PLASTER
SYSTEM WITH 6mm STO
PREMESHED FINISHING EDGE
& STO uPVC END CAP
MS SEALANT ON STO JOINT SEAL
TAPE OR PEF ROD 6mm MIN.GAP
POREN PANEL
STO THERM 20mm
VH CAVITY BATTEN
5
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CORNER - HORIZ.PROFILED METAL/STO POREN
PP 851
2014
SCALE 1:2
COVER
WALL UNDERLAY
MS SEALANT ON STO JOINT SEAL
TAPE OR PEF ROAD 6mm MIN.GAP
POREN PANEL
STO POREN PLASTER SYSTEM
WITH 6mm FINISHING EDGE &
STO uPVC END CAP
COVER
50mm MIN. 50mm MIN.
A5
FIXINGS IN ACCORDANCE
WITH E2/AS1
PROFILED FOAM CLOSURE
STRIP UNDER CLADDING
HORIZONTAL PROFILED METAL
WALL CLADDING (SPECIFY TYPE,
THICKNESS & COATING)
E2/AS1 COMPLIANT FLASHING
10
REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS
HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY
VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY
NOTE:A = CHECK WITH SHEET METAL FOLDER A NARROW NECK
MAY REQUIRE A WELDED JOINT OR TOP HAT
STO THERM 20mm VH
CAVITY BATTEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERT.JUNCTION - HORIZ.PROFILED METAL/STO POREN
PP 852
2014
SCALE 1:2
5
m
m
G
A
P
1. REFER TO E2/AS1 FOR COMPLIANT
PROFILES AND FLASHINGS
2. HORIZONTAL PROFILE METAL WALL
CLADDING IS FIXED ON A DRAINED CAVITY3. VERTICAL PROFILE METAL WALL
CLADDING IS DIRECT FIXED OVER A ROOF
UNDERLAY
4. IN EXTRA HIGH WIND ZONES INCREASE
FLASHING COVER TO 60mm MIN.AND USE
A RIGID UNDERLAY
15
35m
m M
IN
.
CO
VE
R
35m
m M
IN
.
CO
VE
R
FIXINGS IN ACCORDANCE
WITH E2/AS1
CONTINUOUS CAVITY DRAINAGE
CLOSURE STRIP
HORIZONTAL PROFILED METAL WALL
CLADDING (SPECIFY TYPE, THICKNESS &
COATING)
E2/AS1 COMPLIANT METAL
FLASHING
MS SEALANT
POREN PANEL
STOPOREN PLASTER
SYSTEM
SEAL END PANEL WITH S
PROTECT WS 205
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZ.JUNCTION - HORIZ.PROFILED METAL/STO POREN
PP 853
2014
SCALE 1:5
WALL UNDERLAY CONTINUOUS
AROUND CORNERS
POREN PANEL
STOTHERM 20mm VH
CAVITY BATTEN
POREN FIXING
VERTICAL PROFILED METAL
WALL CLADDING (SPECIFYTYPE, THICKNESS &COATING)
STOPOREN
PLASTER SYSTEM
E2/AS1 COMPLIANT METAL
FLASHING
STO uPVC END CAP/MS
SEALANT
STO uPVC 6mm
FINISHING EDGE
FIXINGS IN ACCORDANCE
WITH E2/AS1
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXT.CORNER - VERTICAL PROFILED METAL/STO POREN
PP 854
2014
SCALE 1:2
50m
m C
OV
ER
6m
m G
AP
REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS
HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY
VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY
FIXINGS IN ACCORDANCE
WITH E2/AS1
VERTICAL PROFILED METAL
WALL CLADDING (SPECIFY
TYPE, THICKNESS &
COATING)
E2/AS1 COMPLIANT FLASHING
(SPECIFY COATING)
DOUBLE STUD REQUIRED
STO POREN PLASTER
SYSTEM WITH 6mm STO
PREMESHED FINISHING
EDGE & STO uPVC END CAP
MS SEALANT ON STO JOINT SEAL
TAPE OR PEF ROD 6mm MIN.GAP
POREN PANEL
STO THERM 20mm
VH CAVITY BATTEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INT.CORNER - VERTICAL PROFILED METAL/STO POREN
PP 855
2014
SCALE 1:2
REFER TO E2/AS1 FOR COMPLIANT PROFILES AND FLASHINGS
HORIZONTAL PROFILE METAL WALL CLADDING IS FIXED ON A DRAINED CAVITY
VERTICAL PROFILE METAL WALL CLADDING IS DIRECT FIXED OVER A ROOF UNDERLAY.
FIXING IN ACCORDANCE WITH E2/AS1
50m
m M
IN
.
CO
VE
R
35m
m M
IN
.
CO
VE
R
3.5mm VENTILATION GAP, NON
VENTED CLOSER FLASHING
VERTICAL PROFILED METAL
WALL CLADDING (SPECIFY
TYPE, THICKNESS & COATING)
E2/AS1 COMPLIANT FLASHING
MS SEALANT
STO POREN PLASTER
SYSTEM
ROOF UNDERLAY TO LAP
OVER WALL UNDERLAY BY
75mm MIN.
FLASHING TAPE OVER
SEAL END OF PANEL
WITH S PROTECT WS205
POREN PANEL OVER 20mm
DRAINED CAVITY
POREN FIXING
1
0
m
m
G
A
P
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HORIZ.JUNCTION - VERT.PROFILED METAL/STO POREN
PP 856
2014
SCALE 1:2
WALL UNDERLAY
CONTINUOUS AROUND
CORNERS, FLASHING TAPE
APPLIED TO PROTECT WALL
UNDERLAY 75mm MIN.WIDE
STO THERM 20mm VH
CAVITY BATTEN
POREN PANEL
STO POREN
PLASTER SYSTEM S
PROTECT WS 205
TO SEAL END PANEL
PORENFIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
EXTERNAL CORNER - STOTHERM/STO POREN
PP 860
2014
SCALE 1:2
6
MS SEALANT OVER STO JOINT
SEAL TAPE OR PEF ROD 6mm
MIN.GAP
50mm STOTHERM PANEL WITH
STOARMAT PLASTER SYSTEM
TO FINISH
STOTHERM FIXING
50m
m M
IN
.
50mm MIN.
STOTHERM uPVC END CAP
WALL UNDERLAY CONTINUOUS
AROUND CORNERS
STO THERM 20mm VH
CAVITY BATTEN
POREN PANEL
STOPOREN PLASTER SYSTEM WITH
6mm FINISHING EDGE. S PROTECT WS
205 TO SEAL END
E2/AS1 COMPLIANT
FLASHING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTERNAL CORNER - STOTHERM/STO POREN
PP 861
2014
SCALE 1:2
50mm MIN. 50mm MIN.
WALL UNDERLAY
E2/AS1 COMPLIANT
HEMED METAL
FLASHING
50mm STOTHERM PANEL WITH
STOARMAT PLASTER SYSTEM TO
FINISH
STOTHERM FIXING
STOTHERM END CAP
STO POREN PLASTER SYSTEM S
PROTECT WS 205 TO SEAL END PANEL
USE A POLY PACKER TO FORM GAP
IN BASECOAT BEFORE INSTALLING
STO uPVC CONTROL JOINT
STO THERM 20mm
VH CAVITY BATTEN
POREN PANEL
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL JOINT - 50mm STOTHERM/STO POREN
PP 862
2014
SCALE 1:2
50mm MIN. 50mm MIN.
WALL UNDERLAY
MS SEALANT ON STO JOINT SEAL
TAPE OR PEF ROAD 6mm MIN.GAP
E2/AS1 COMPLIANT
HEMED METAL FLASHING
POREN PANEL
NOTE: ADJUST FOR SELECTED STOTHERM PANEL SIZES - 60, 80 OR 100mm
(SHOWN - 50mm PANEL)
STO POREN PLASTER SYSTEM WITH
6mm PREMESHED FINISHING EDGE &
STO uPVC END CAP
STO THERM 20mm VH
CAVITY BATTEN
50mm STOTHERM PANEL WITH
STOARMAT PLASTER SYSTEM
TO FINISH
STOTHERM FIXING
STO uPVC 6mm
FINISHING EDGE
POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
VERTICAL JOINT - 80mm STOTHERM/STO POREN
PP 863
2014
SCALE 1:2
50mm STOTHERM PANEL
WITH STOARMAT PLASTER
SYSTEM TO FINISH
STOTHERM uPVC
END CAP
20mm CAVITY
STO POREN PLASTER SYSTEM S
PROTECT WS 205 TO SEAL END PANEL
8-12m
m G
AP
POREN PANEL
20mm CAVITY
NOTE: UP TO A MAX. OF TWO STOREYS OR 7 METERS IN HEIGHT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
INTER-STOREY JUNCTION - STOTHERM/STO POREN
PP 864
2014
SCALE 1:2
50mm STOTHERM PANELWITH STOARMAT PLASTERSYSTEM TO FINISH
STO uPVC BASEEND CAP
20mm CAVITY
STO POREN PLASTER SYSTEM SPROTECT WS 205 TO SEAL END PANEL
POREN PANEL
20mm CAVITY
1. DRAINED INTER-STOREY FLASHING REQUIRED TO LIMITCONTINUOUS CAVITY CONSTRUCTION TO TWO(2) STOREYS, GABLEEND OR 7 METERS
2. IN EXTRA HIGH WIND ZONES INCREASE FLASHING COVER TO 60mmMIN.AND USE A RIGID UNDERLAY
3535
5
15° SLOPE TOINTER-STOREY FLASHING
CAVITY BASE CLOSERPOSTIONED TO GIVE 15mmMIN.DRIP EDGE TO CLADDING
ADDITIONAL WALL UNDERLAYDRESSED OVER FLASHING
ALLOW TO PLASTER BEHINDTHEN SEAL WITH MS SEALANTOR STO SEAL TAPE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
THIRD STOREY DRAINED INTER-STOREY JUNCTION
PP 865
2014
SCALE 1:2
AIRSEAL ON PEF RODGAP 7.5-8mm APPROX
TIMBER LINTEL ASPER NZS 3604
INTERNAL LINING
ARCHITRAVE ORSLIMLINE DETAIL
TIMBER WINDOW HEAD -PROFILE TO NZS 3610
FLEXIBLE FLASHING TAPEINSTALLED OVER WALL
UNDERLAY AT CORNERS
POREN PANEL
STO POREN PLASTERSYSTEM
20mm DRAINED &VENTED CAVITY -BATTENS AT 300 -600mm MAX.CTRS.
FLASHING TAPE ONTOWALL UNDERLAY andOVER ALU.HEADFLASHING
STO uPVC VENTEDBASE CAP WITHMIN 5mm GAP
E2/AS1 COMPLIANT HEADFLASHING, STOP ENDEDWITH 15° SLOPE AND10mm COVER
MIN. 5mm GAP REQUIRED10
5
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER WINDOW JOINERY - HEAD DETAIL
PP 870
2014
SCALE 1:2
CONTINUOUS
PACKING
MS SEALANT
20mm DRAINED & VENTED
CAVITY - BATTENS AT
300-400mm MAX CTRS.
WALL UNDERLAY
TURNED INTO
FRAMING REVEALS
AND TAPED AT
CORNERS
E2/AS1 COMPLIANT SILL
FLASHING WITH
STOP-END, LAPPED
UNDER JAMB FLASHING
TIMBER WINDOW SILL
TO NZS 3610
AIRSEAL ON PEF ROD
GAP 7.5-8mm APPROX
FLEXIBLE FLASHING
TAPE INSTALLED OVER
WALL UNDERLAY AT
CORNERS
10
STO POREN PLASTER
SYSTEM
STO POREN PANEL END
SEAL WITH S PROTECT
WS 205
STO uPVC 6mm
PREMESHED
FINISHING EDGE
25m
m M
IN
.
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER WINDOW JOINERY - SILL DETAIL
PP 871
2014
SCALE 1:2
STOPOREN PLASTER
SYSTEM
POREN PANEL
POREN FIXING
LINE OF HEAD
FLASHING
LINE OF SILL
FLASHING - LAPPED
UNDER JAMB PACKING
E2/AS1 COMPLIANT JAMB
FLASHING NOTCHED INTO TIMBER
WINDOW SILL JOINERY WITH STO
SEALANT OVER FIXINGS
TIMBER JAMB -
PROFILE TO NZS 3610
INTERNAL LINING
AIRSEAL GAP 7.5-8mm
APPROX
ARCHITRAVE OR
SLIMLINE DETAIL
JAMB PACKER TO
SUIT REBATE
WALL UNDERLAY TURNED
INTO FRAMING REVEALS
AND TAPED AT CORNERS
STO STICK ON JOINERY
CONNECTOR ON JAMB FLASHING
STO PREMESHED
CORNER ANGLE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER WINDOW JOINERY - JAMB DETAIL
PP 872
2014
SCALE 1:2
TIMBER DOOR SILL TO
NZS 3610
BOUNDARY JOISTS
20mm CAVITY BATTENS
@ 300-400mm MAX.
CTRS
50
AIR SEAL
WALL UNDERLAY
TURNED INTO
FRAMING REVEALS
E2/AS1 COMPLIANT
SILL FLASHING STOP
ENDED AND LAPPED
UNDER JAMB PACKERS
MS SEALANT
STO uPVC 6mm
PREMESHED
FINISHING EDGE
KEEP WALL
UNDERLAY &
BATTENS 20MM UP
FROM BOTTOM EDGE
OF CLADDING
STO POREN PLASTER
SYSTEM
STO uPVC VENTED
BASE CAP or FOOT
TRAY
DPC
STO POREN PANEL
FLASHING TAPE 100mm
MIN.UPSTAND TO
JAMBS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER DOOR JOINERY - TIMBER FLOOR THRESHOLD DETAIL
PP 873
2014
SCALE 1:2
UPSTAND TO SUIT
FLOOR FINISHES
NOTE: SILL TO BE SNUG
FIT AS AIR SEAL
PLASTER FURRING
CONCRETE SLAB
TIMBER SILL TO NZS
3610
DPC OVER PLASTER
FURRING
TIMBER TRIM UNDER
THRESHOLD
FLASHING TAPE 100mm
MIN.UPSTAND TO JAMBS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
TIMBER DOOR JOINERY - CONC.FLOOR THRESHOLD DETAIL
PP 874
2014
SCALE 1:2
50m
m
AIRSEAL OVER PEFROD GAP 7.5-8mm
APPROX
TIMBER LINTEL ASPER NZS 3604
INTERIOR LINING
WALL UNDERLAY
POREN PANEL
STO POREN PLASTERSYSTEM
20mm DRAINED CAVITY
35m
m M
IN.
FLASHING TAPE ONTO WALLUNDERLAY
STO uPVC VENTED BASECAP
ALUMINUM WINDOW HEADFLASHING MIN.15° SLOPEAND 10mm COVER ATWINDOW HEAD
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED FORVERY HIGH AND EXTRAHIGH WIND ZONESPROPRIETARY NK PVCuWINDOW SYSTEM
5
1. IN EXTRA HIGH WIND ZONESINCREASE FLASHING COVER TO 60mmAND USE A RIGID UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
NK PVCu JOINERY - HEAD DETAIL
PP 875
2014
SCALE 1:2
JOINERY SUPPORT
BAR REQUIRE FOR
OPENINGS OVER
600mm
PROPRIETARY NK PVCu
WINDOW SYSTEM
MS SEALANT
STO uPVC SILL
FLASHING FOR NK
PVCu JOINERY
POREN PANEL
20mm DRAINED
CAVITY
FRAME BLOCK
TIMBER FRAMING
TO NZS 3604
WALL UNDERLAY
RETURNED INTO
OPENINGS & FLASHING
TAPE CONTINUOUS ALONG
SILL MIN 100mm UP JAMBS
& 50mm ONTO FACE OF
WALL UNDERLAY
AIRSEAL ON PEF ROD GAP
7.5-8mm APPROX.
INTERIOR LINING
STO POREN
PLASTER SYSTEM
STO PREMESHED
uPVC CNR
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
NK PVCu JOINERY - SILL DETAIL
PP 876
2014
SCALE 1:2
STO THERM 20mm VH
CAVITY BATTEN
FLASHING TAPE
(100mm UP JAMBS)
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
NK PVCu JOINERY - JAMB DETAIL
PP 877
2014
SCALE 1:2
PROPRIETARY TAPE OVER
HEAD FLASHING SUPPLIED
AND INSTALLED BY FLASHMAN
CONTRACTOR
FLASHMAN EXTRUDED ALUMINIUM
ONE PIECE CAVITY CLOSURE AND
HEAD FLASHING WITH STOP END
(SHOWN DASHED)
5
AIRSEAL OVER PEF
ROD GAP 7.5-8mm
APPROX
TIMBER LINTEL AS
PER NZS 3604
INTERIOR LINING
WALL UNDERLAY
POREN PANEL
STO POREN PLASTER
SYSTEM
20mm DRAINED CAVITY
STO POREN uPVC VENTED
BASE TRAY
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED FOR
VERY HIGH AND EXTRA
HIGH WIND ZONES
ALUMINIUM WINDOW
JOINERY
25
25mm MIN. FROM OUTSIDE OF FRAMING
TO BACK OF WINDOW FLANGE
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FLASHMAN HEAD FLASHING
PP 878
2014
SCALE 1:2
FLASHMAN ALUMINIUM
MITRE SOAKER
SUPPLIED BY FLASHMAN
INSTALLED BY BUILDER
H3.1 PACKER SUPPLIED
AND INSTALLED BY
FLASHMAN
14 GAUGE HOT DIP
GALV.(316SS WHERE
REQ.) S.T.H.C SCREWS @
600mm CTRS. WITH 65mm
MIN. FRAME
PENETRATION. SUPPLIED
BY FLASHMAN
STO POREN PLASTER
SYSTEM
20mm DRAINED CAVITY
TIMBER FRAMING
TO NZS 3604
WALL UNDERLAY RETURNED
INTO OPENINGS & FLASHING
TAPE CONTINUOUS ALONG
SILL MIN 100mm UP JAMBS &
50mm ONTO FACE OF WALL
UNDERLAY
AIRSEAL ON PEF ROD
GAP 7.5-8mm APPROX.
FLASHMAN EXTRUDED
ALU.EURO SILL WITH END CAP
- SHOWN DASHED
25mm MIN. FROM OUTSIDE
FACE OF THE FRAMING LINE TO
THE BACK OF WINDOW FLANGE
25
STO STICK ON JOINERY
CONNECTOR 8mm MIN.
SUPPORT PACKER
8
FLASHMAN BACK PLATE -
SHOWN DASHED
ALT.METRO SILL -
SHOWN DASHED
STO POREN FIXING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FLASHMAN SILL FLASHING
PP 879
2014
SCALE 1:2
FLASHMAN EXTRUDED
ALUM.JAMB FLASHING
25mm MIN. FROM OUTSIDE
FACE OF FRAMING TO
BACK OF WINDOW FLANGE
25
SEAL PANEL END - S
PROTECT WS 205
LINE OF ALT.METRO SILL
BELOW - SHOWN
DASHED
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
FLASHMAN JAMB FLASHING
PP 880
2014
SCALE 1:2
AIRSEAL OVER PEFROD GAP 7.5-8mm
APPROX
TIMBER LINTEL ASPER NZS 3604
INTERIOR LINING
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED FORVERY HIGH AND EXTRAHIGH WIND ZONESPROPRIETARY HOMERITPVC WINDOW JOINERY
ALUMINIUM WINDOW HEADFLASHING MIN.15° SLOPE AND10mm COVER AT WINDOWHEAD
5
WALL UNDERLAYINSTALLED AS PERE2/AS1
POREN PANELSTO POREN PANELPLASTER SYSTEM
20mm DRAINEDCAVITY
FLASHING TAPE ONTOWALL UNDERLAYSTO uPVC VENTEDBASE CAP
STO CAVITY JAMBFLASHING STOPENDS
1. IN EXTRA HIGH WIND ZONESINCREASE FLASHING COVER TO60mm AND USE A RIGID UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HOMERIT PVC JOINERY - HEAD DETAIL
PP 881
2014
SCALE 1:2
STO POREN
PLASTER SYSTEM
STO POREN FIXING
20mm DRAINED
CAVITYTIMBER FRAMING
TO NZS 3604
WALL UNDERLAY RETURNED
INTO OPENINGS & FLASHING
TAPE CONTINUOUS ALONG
SILL MIN 100mm UP JAMBS &
50mm ONTO FACE OF WALL
UNDERLAY AS PER E2/AS1
AIRSEAL ON PEF ROD
GAP 7.5-8mm APPROX.
INTERIOR LINING
JOINERY SUPPORT BAR
REQUIRE FOR
OPENINGS OVER 600mm
PROPRIETARY HOMERIT
PVC WINDOW JOINERY
MS SEALANT
STO uPVC
ADJUSTABLE CNR
STO POREN PANEL
5mm GAP BETWEEN
JOINERY & PLASTER
STO uPVC CAVITY
FACE FIXED SILL &
JAMB FLASHING
5
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HOMERIT PVC JOINERY - SILL DETAIL
PP 882
2014
SCALE 1:2
FLASHING TAPE AS
PER E2/AS1
H1.2 PACKER TO
SUPPORT JOINERY
AIRSEAL ON PEF ROD
GAP 7.5-8mm APPROX.
PROPRIETARY HOMERIT
PVC WINDOW JOINERY
MS SEALANT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING SYSTEM
HOMERIT PVC JOINERY - JAMB DETAIL
PP 883
2014
STOPOREN PANEL PANEL (40mm cavity)SYSTEM
THE STOPOREN PANEL VENEER SYSTEM HAS BEEN APPRAISED AS AN EXTERNAL WALL CLADDING SYSTEM FORBUILDINGS WITHIN THE FOLLOWING SCOPE:• THE SCOPE LIMITATIONS OF NZBC ACCEPTABLE SOLUTION E2/AS1, PARAGRAPH 1.1; AND,• CONSTRUCTED WITH TIMBER FRAMING COMPLYING WITH THE NZBC; AND,• WITH A RISK SCORE OF 0-20, CALCULATED IN ACCORDANCE WITH NZBC ACCEPTABLE SOLUTION E2/AS1, TABLE 2;
AND,• SITUATED IN NZS 3604 WIND ZONES UP TO, AND INCLUDING ‘EXTRA HIGH’.
THE STOPOREN PANEL VENEER SYSTEM HAS ALSO BEEN APPRAISED FOR WEATHERTIGHTNESS AND STRUCTURALWIND LOADING WHEN USED AS AN EXTERNAL WALL CLADDING SYSTEM FOR BUILDINGS WITHIN THE FOLLOWING SCOPE:• THE SCOPE LIMITATIONS OF NZBC ACCEPTABLE SOLUTION E2/AS1, PARAGRAPH 1.1; AND,• CONSTRUCTED WITH TIMBER OR STEEL FRAMING COMPLYING WITH THE NZBC; AND,• SITUATED IN SPECIFIC DESIGN WIND PRESSURES UP TO A MAXIMUM DESIGN DIFFERENTIAL ULTIMATE LIMIT STATE
(ULS) OF 2.5 KPA.
NOTE: REFER TO STO POREN PANEL CLADDING SYSTEM FOR COMPREHENSIVE SET OF ACAD DETAILS
STOPOREN PLASTER SYSTEM
INCORPORATING:1. S-PROTECT WS 205 SEALER TO SEAL POREN PANELS2. STOPOREN PLASTER 25kg BAG3. STOPLEX W SEALER 10lt CONTAINER4. STOLIT K or MP COLOURED FINISHING RENDER 25kg PAIL5. STOCOLOR MAXICRYL FACADE PAINT 15lt PAIL
STOLASTIC COLOR FACADE PAINT 15lt PAILSTOLOTUSAN COLOR G 15lt PAIL
STOARMAT MIRAL PLASTER SYSTEMCAN ALSO BE USED FOR ADDITIONAL STRENGTH AND REINFORCEMENT
CAVITY SPACERS FIXING SYSTEM:
• 40mm x MINIMUM 200 LONG H3.1 TIMBER SPACERS FIXED WITH 75 x 3.06 GALVANIZED RING SHANK NAILS ANDSECURE PANEL WITH 75MM POREN FIXINGS COUNTERSUNK 10mm.
STO 40mm VH POLYSTYRENE CAVITY BATTENS:
• TEMPORARILY FIX CONTINUOUS STO 40mm CAVITY BATTENS TO FRAMING (OVER WALL UNDERLAY) AND SECUREPANEL WITH 120mm POREN FIXINGS COUNTERSUNK 5mm TO MAXIMUM 12MM.
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
INTRODUCTION
PP 1000
2014
2200
2020
0mm
STE
EL
RE
INFO
RC
ING
CE
NTR
ES
25 55 SCALE NTS
600
5050
050
600
PANEL FIXING OVER40mm H3.1 TIMBER SPACERS
50
FIXINGS
FIXINGS
170 155165
200
200
200
200
200
160
200
200
200
200
200
STEEL REINFORCING
150
300
150
600
PANEL FIXING OVER40mm STO CAVITY BATTEN
50
FIXINGS
FIXINGS
POREN PANELAUTOCLAVED AERATEDCONCRETE DENSITY 600kg/m²THERMAL RESISTANCE RV 0.30 ONCAVITY CONSTRUCTION
POREN PANEL DIMENSIONS2200x600x50mmFREIGHT20 PANELS / DOUBLE PALLET1.3m² / PALLET + PALLETAREA: 1.32m² / PANELWEIGHT: 42kg / PANEL
POREN PANELON 40mm CAVITYTIMBER SPACERS to be MIN.200mmLONG X40mm x 40mmCAVITY BATTEN40mm STO VH POLY BATTEN40mm H3.1 TIMBER BATTEN
BEVELED EDGEOF PANEL FACESFRAMING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
INFORMATION
PP 1001
2014
SCALE 1:20
TIMBER FRAMING TO
NZS 3604
STOPOREN PLASTER SYSTEM
- S-PROTECT WS 205 SEALER
- POREN PLASTER MESH PLASTER
- STOLIT K COLOURED
FINISHING RENDER
- STOCOLOR PAINT
H3.1 CAVITY SPACERS AT
MAX. 600mm CENTRES ON
FRAMING
50m
m m
in.
9
0
m
m
m
i
n
.
R
E
B
A
T
E
WALL UNDERLAY MEETING
REQUIREMENTS OF E2/AS1
NOTE: BUILDER REQUIRED TO
PROVIDE STRAPS AT MAX.
300mm CENTRES FOR STUDS
OVER 450mm CENTRES
NOTE:600mm FRAMING
TWO 75mm POREN FIXINGS EITHER SIDE OF PANEL JOINTS MIN
40mm FROM EDGE INTO CAVITY SPACER
SEE PP 1003 FOR NON REBATED DOUNDATION
CONCRETE FOUNDATION
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
CAVITY SPACER SETOUT (600ctrs)
PP 1002
2014
SCALE 1:20
TIMBER FRAMING
TO NZS 3604
STOPOREN PLASTER SYSTEM
- S-PROTECT WS 205 SEALER
- STOPOREN MESH PLASTER
- STOLIT K COLOURED
FINISHING RENDER
- STOCOLOR PAINT
STO VH 40mm or H3.1 TIMBER
40mm CAVITY BATTEN AT 300mm
CENTRES ON 600mm FRAMING
50m
m m
in.
WALL UNDERLAY MEETING
REQUIREMENTS OF E2/AS1
NOTE:600mm FRAMING
120mm POREN FIXINGS AT 300mm CENTRES GENERALLY 150mm
FROM PANEL EDGE WITH ONE FIXING BETWEEN STUDS ON THE
BOTTOM PLATE
SEE PP 1002 FOR REBATED FOUNDATION
CONCRETE FOUNDATION
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm Cavity) SYSTEM
CAVITY BATTEN SETOUT (600ctrs)
PP 1003
2014
SCALE 1:20
TIMBER FRAMING
TO NZS 3604
STO VH 40mm or H3.1 TIMBER
CAVITY BATTENS
STOPOREN PLASTER SYSTEM
- S-PROTECT WS 205 SEALER
- POREN PLASTER
MESH COAT
- STOPLEX W SEALER
- STOLIT K COLOURED
FINISHING RENDER
- STOCOLOR PAINT
NOTE:400mm FRAMING
FIXINGS AT 300mm CENTRES GENERALLY 150mm FROM PANEL
EDGE
SEE PP 1002 FOR REBATED FOUNDATION
50m
m m
in.
POREN ADHESIVE
ON PANEL JOINTS
POREN PANEL
CONCRETE FOUNDATION
STO uPVC
ADJUSTABLE FOOT
TRAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
CAVITY BATTEN SETOUT (400ctrs)
PP 1004
2014
DOOR WINDOW
FOUNDATION
FRAMING STUDS AT 600mm CENTRES
SCALE NTS
SOFFIT PLATE
40 40
200
22.5
°
33 40
200
H3.1 TIMBER CAVITYSPACERS FOR 40mmOR 33mm CAVITY
22.5
°
75 mm POREN FIXINGSJOINT TO FIX PANEL
50 mm PORENPANEL
FIX SPACERS WITH 275mm x 3.06GALVANIZED RINGSHANK NAILS
MINIMUM REBATE IN FOUNDATION 50mm OR HANGPANEL 50mm PAST FOUNDATION.FOR 40mm BATTENSYSTEM LAYOUT REFER - PP 1002, 1003 or 1004
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
CAVITY BATTEN SETOUT (400ctrs) - ELEVATION
PP 1005
2014
SCALE 1:5
TIMBER FRAMING
TO NZS 3604
DPC
INTERNAL LINING
DPM
FOR 1 OR 2 STOREYS
50
10
INSULATION TO EXTERIOR
WALLS
GL
*100
* DIM.FOR
UNPROTECTED
GROUND. REFER
NZS3604 FIG.7.11
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN - NOT SHOWNFOR CLARITY
STO PLASTER SYSTEM
INSULATION AS
PER NZBC H1/AS1
100m
m M
IN
.50m
m
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
REBATED SLAB-ON-GROUND - CAVITY SPACER
PP 1006
2014
SCALE 1:5
DPC
50
AS PER NZS 3604
DPM
6
CONCRETE SLAB/REINFORCING
AS PER NZS 3604 OR ENGINEER
SPECIFIC DESIGN - NOT SHOWNFOR CLARITY
INSULATION AS
NZBC H1/AS1
100m
m M
IN
.
plaster
50m
m
flexyl
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
FOUNDATION SLAB-ON-GROUND - CAVITY SPACER
PP 1007
2014
SCALE 1:2
POREN MINERAL PANEL
ADHESIVE OR AAC 2 HR
CONSTRUCTION GLUE ON ALL
PANEL JOINTS
WALL UNDERLAY
CONTINUOUS AROUND
CORNERS AS PER E2/AS1
STO PREMESHED
CORNER BEAD
STOPOREN PLASTER
SYSTEM
POREN PANEL
NOTE: USE 120mm POREN FIXINGS FOR
40mm STO VH CAVITY BATTENS or 75mm
POREN FIXINGS ON H3.1 TIMBER SPACERS
SELECTED H3.1 TIMBER
CAVITY SPACERS or STO
CAVITY BATTENS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
EXTERNAL CORNER
PP 1008
2014
SCALE 1:2
NOTE: USE 120mm POREN FIXINGS FOR
40mm STO CAVITY BATTENS or 75mm
POREN FIXING ON CAVITY SPACERS
POREN MINERAL PANEL
ADHESIVE OR AAC 2 HR
CONSTRUCTION GLUE ON ALL
PANEL JOINTS
WALL UNDERLAY
CONTINUOUS AROUND
CORNER AS PER E2/AS1
LAP STO MESH 75mm MIN.
BOTH WAYS
STO VH CAVITY 40mm
BATTENS or H3.1 TIMBER
SPACERS
STOPOREN PLASTER
SYSTEM
POREN PANEL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
INTERNAL CORNER
PP 1009
2014
SCALE: 1:2
10mm GAP IN PANELS
NOTE:ENSURE POREN PANELS ARE SUPPORTED BY A MAX.OF 2/STUDS. VERTICAL CONTROL
JOINTS ARE REQUIRED AT 8.0M MAX.CTRS. ADHERE STO CONTROL JOINT AND
REMOVE TAB CAREFULLY AS SOON AS THE JOINT IS SET TO AVOID CRACKS.
USE 120mm POREN FIXINGS FOR 40mm H3.1 TIMBER CAVITY BATTENS or 75mm POREN
FIXING FOR CAVITY SPACERS
STO uPVC CONTROL JOINT. FILL WITH
MS SEALANT or SEAL JOINS, PAINT
AND LEAVE AS A NEGATIVE DETAIL
300mm MAX.CTRS
STOPOREN PLASTER
SYSTEM
40mm H3.1 TIMBER
CAVITY SPACER or
40mm STO VH CAVITY
BATTEN
POREN PANEL
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
VERTICAL CONTROL JOINT
PP 1010
2014
SCALE: 1:2
A
WALL UNDERLAY - ENSURE
UNDERLAY RUNS
CONTINUOUS OVER JOINT
POREN PANEL
H3.1 TIMBER CAVITY
SPACER or 40mm STO VH
CAVITY BATTEN
STOPOREN PLASTER
SYSTEM
POREN PANEL
STOPOREN PLASTER
SYSTEM
STOPOREN PLASTER
SYSTEM
H3.1 TIMBER CAVITY
SPACER or 40mm STO VH
CAVITY BATTEN
NOTE:POREN PANEL 75mm FIXING
ON CAVITY SPACERS or
120mm FIXINGS ON 40mm
STO VH CAVITY BATTENS. A
STO PVC 12mm CONTROL
JOINT IS REQUIRED ON
UNSEASONED JOISTS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
HORIZONTAL INTER-STOREY JOINT
PP 1011
2014
SCALE: 1:2
A
WALL UNDERLAY - ENSURE
UNDERLAY RUNS
CONTINUOUS OVER JOINT
POREN PANEL 75mm FIXING
ON CAVITY SPACERS or
120mm FIXINGS ON 40mm
CAVITY BATTENS
H3.1 TIMBER CAVITY
SPACER or 40mm STO VH
CAVITY BATTEN
STOPOREN PLASTER
SYSTEM
POREN PANEL
STOPOREN PLASTER
SYSTEM
H3.1 TIMBER CAVITY
SPACER or 40mm STO VH
CAVITY BATTEN
INSTALL STO uPVC 12mm
CONTROL JOINT WITH MS
SEALANT or FORM
NEGATIVE DETAIL
15
12m
m
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
HORIZONTAL INTER-STOREY CONTROL JOINT
PP 1012
2014
40mm H3.1 CAVITY
SPACER or 40mm STO VH
CAVITY BATTEN
FLASHING TAPE OVER
STO uPVC VENTED
BASE CAP with
EXTENSION INSERT
ALLOW TO PLASTER
BEHIND THEN SEAL
WITH MS SEALANT OR
STO SEAL TAPE
AS REQUIRED TO LIMIT
CONTINUOUS CAVITY
CONSTRUCTION TO
TWO STOREYS
FLASHING BACK AND
FRONT COVER TO BE A
MINIMUM 35mm
EXCLUDING DRIP
EDGES
SCALE: 1:2
MIN
.C
OV
ER
MIN
.C
OV
ER
35
35
STO PLASTER SYSTEM
POREN PANEL
WALL UNDERLAY -
ENSURE UNDERLAY
RUNS CONTINUOUS
OVER JOINT
WALL UNDERLAY - ENSURE
UNDERLAY RUNS
CONTINUOUS OVER JOINT
5
1. IN EXTRA HIGH WIND
ZONES INCREASE
FLASHING COVER TO
60mm MIN.AND USE A
RIGID UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
DRAINED JOINT AT THIRD STOREY
PP 1013
2014
SCALE 1:2
40mm H3.1 TIMBERSPACER or STO VH
CAVITY BATTEN
FLASHING TAPE SEALED 50mmTOMETERBOX AND 100mm TO WALLUNDERLAY
8mm AIRSEAL ON PEFROD BY BUILDER
NOTE: USE 120mm POREN FIXINGSFOR 40mm CAVITY BATTENS or75mm POREN FIXINGS WITH CAVITYSPACERS
STO POREN PANEL SEAL ENDWITH S PROTECT WS 205
MS SEALANT OVER STO JOINTSEAL TO PERIMETER OF
METERBOXSTO uPVC FINISHING EDGE
STOPORENPLASTER SYSTEM
40mm CAVITY BATTEN SLOPED MIN.5° EXTENDING PAST SERVICE BOX
WITH FLASHING TAPE OVERBATTEN & 50mm MIN.ONTO
UNDERLAY
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
SERVICE BOX DETAIL
PP 1014
2014
NOTE:FLASHING TAPE SYSTEM TO BE INSTALLEDAROUND JOINERY OPENINGS AS PER E2/AS1USE 120mm POREN FIXINGS FOR 40mm CAVITYBATTENS or 75mm POREN FIXINGS ON CAVITYSPACERS
SCALE 1:2
TIMBER LINTEL ASPER NZS 3604
STO POREN PLASTERSYSTEM
FLASHING TAPE ONTOWALL UNDERLAY
STO POREN PANEL
ALUMINIUM WINDOWHEAD FLASHING WITH 15°SLOPE AND 10mm COVERAT WINDOW HEAD
MIN. 5mm GAP REQUIRED
SEALANT REQUIRED FORVERY HIGH AND EXTRAHIGH WIND ZONES
35m
m M
IN.
50m
m
ALUMINIUM WINDOWJOINERY
INTERIOR LINING
AIRSEAL ON PEFROD GAP 7.5-mm STO uPVC VENTED
BASE CAP withEXTENSION INSERT
HEAD FLASHING WITH10mm STOPENDSPOSITIONED 10mmPAST WINDOW JAMBS
STO uPVC STICK ONFLASHING TO FINISH ATHEAD FLASHING WITHPUNCHED PLASTERLEG CONTINUING 30mmABOVE
5
H3.1 CAVITY SPACERor 40mm CAVITYBATTEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
ALUMINIUM WINDOW JOINERY - HEAD DETAIL
PP 1015
2014
SCALE 1:2
NOTE: OPENINGS OVER 600mm REQUIRE JOINERY SUPPORT BAR USE 120mm POREN FIXINGS FOR 40mm CAVITY BATTENS and 75mm FIXINGS FOR CAVITY SPACERS
JOINERY SUPPORT MUST BE CUT 15mm SHORT OF JOINERY JAMBS TO ALLOW FOR STO uPVC FLASHINGS1. SEALANT IS APPLIED TO THE SILL AND JAMB FLASHINGS2. WINDOW HEADS ARE LEFT OPEN3. FLEXIBLE FLASHING TAPE SYSTEM TO BE INSTALLED AROUND JOINERY OPENINGS AS PER E2/AS1
WARNING: SOME BRANDS OF ALUMINIUM JOINERY HAVE DRAINAGE VENTS IN THE BOTTOM EDGE OF THE SILL FLANGE. ENSURE DRAINAGE VENTS REMAIN CLEAR.
JOINERY SUPPORT BARREQUIRE FOROPENINGS OVER 600mm
PROPRIETARYALUM.WINDOWJOINERY
MS SEALANT
STOPOREN PLASTERSYSTEM
STO POREN PANEL
FRAME BLOCK
AIRSEAL ON PEF ROD GAP7.5mm APPROX.
STOPOREN FIXING
STO CAVITY SPACERFIXED 2/75mm x 3.06GALV.RING SHANK NAILS
STO uPVC STICK ONFLASHING, ADHESIVE FIXTO PANEL AT 15° SLOPE
STO PRE-MESHEDANGLE
WALL UNDERLAY RETURNED INTOOPENINGS & FLASHING TAPE
CONTINUOUS ALONG SILL MIN 100mm UPJAMBS & 50mm ONTO FACE OF WALL
UNDERLAY
APPLY S PROTECT WS 205SEALER BEFORE PLASTERING
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
ALUMINIUM WINDOW JOINERY - SILL DETAIL
PP 1016
2014
NOTE:NSTALL STOPOREN JOINERY FLASHING DURING POREN
PANEL CONSTRUCTION USE 120mm POREN FIXING FOR 40mm
CAVITY BATTENS and 75mm FIXINGS FOR CAVITY SPACERS
SCALE 1:2
10mm6
H1.2 PACKER TO
SUPPORT JOINERY
WALL UNDERLAY RETURNED INTO RECESS
WITH FLASHING TAPE SYSTEM. FLASHING
TAPE RETURNED min 100mm UP JAMBS
STOPOREN PLASTER
SYSTEM
STO POREN PANEL
STOPOREN 75mm
FIXING
H3.1 CAVITY SPACER or
40mm CAVITY BATTEN
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL CLADDING (40mm cavity) SYSTEM
ALUMINIUM WINDOW JOINERY - JAMB DETAIL
PP 1017
2014
Z
Z
5°
35
150
CARRY MESH/PLASTERUP TO TOP EDGE
WALL UNDERLAY CONTINUOUSOVER TOP OF WALL FRAME
POREN PANEL
STO POREN PLASTERSYSTEM
REFER TABLE 7- E2/AS1
POREN FIXING
PROVIDE SEPARATION (ROOFUNDERLAY) UNDER METAL
CAPPING AND 15mm H3 PLY -PACKED TO A FALL
PRE FINISHED METAL CAPPINGTO PARAPET WITH 5° MIN.FALL
40mm DRAINEDCAVITY
H3.1 CAVITY SPACER or 40mmCAVITY BATTEN
STO uPVC VENTEDBASE CAP WITHEXTENSION INSERT
NOTE:H3.1 CAVITY SPACERS DETAILED ALTERNATIVELY -USE 120mm POREN FIXINGS or 40mm CAVITYBATTENS @ 300mm CTRS
BALUSTRADE 1000MMIN.HEIGHT FROM DECK
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
PARAPET/BALUSTRADE DETAIL - METAL CAP
PP 1018
2014
SCALE 1:5
35
150
POREN PANEL
STO POREN PLASTERSYSTEMSTO uPVC VENTEDBASE CAP WITHEXTENSION INSERT
75
75
10°POREN CAP AT 10°
OVERSEATS WALLS,GLUE TO POREN WALL
CLADDING
H3.1 PACKER CUT TO10° SLOPE WITH 15mm
PLYWOOD WITHFLASHING TAPE OR
ROOFING UNDERLAYWALL UNDERLAY CONTINUOUSOVER TOP OF WALL FRAME
POREN PANELSTO POREN PLASTERSYSTEM
40mm DRAINEDCAVITY
POREN FIXING
OVERLAY OF STO FLEXYL MEMBRANEUNDER MESH COAT TO TOP & SIDES,75mm MIN.DOWNTURN OVER BASECOAT
STO PREMESHED uPVC ADJUSTABLECORNERS
H3.1 CAVITY SPACER or 40mmCAVITY BATTEN
BALUSTRADE 1000M MIN.HEIGHT FROM DECK
NOTE:H3.1 CAVITY SPACERS DETAILEDALTERNATIVELY - USE 120mm POREN FIXINGSor 40mm CAVITY BATTENS @ 300mm CTRS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
PARAPET/BALUSTRADE DETAIL - PLASTERED FINISH
PP 1019
2014
SCALE 1:5
140 140
370
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
PARAPET and/or ENCL.BALUSTRADE TO WALL - PLAN
PP 1020
2014
SCALE 1:5
10° MIN.FALL TO TOP OFPARAPET
10°15mm H3 PLYWOOD OVER
H3.1 TIMBER PACKER WITHFLASHING TAPE or ROOFING
UNDERLAY
POREN PANELSTO POREN PLASTER
SYSTEM
WALL UNDERLAYCONTINUOUS
OVER TOP OF WALL FRAME
H3.1 CAVITY SPACERS or40mm CAVITY BATTENS
NOTE:HANDRAIL REQUIRED WHERE BALUSTRADE IS UNDER 1000M.ADHERE PANEL JOINTS WITH POREN MINERAL PANELADHESIVE or AAC 2hr CONSTRUCTION GLUE. HANDRAIL &FIXINGS TO HAVE 50x3mm EPDM WASHERS AROUND FIXINGS.USE 120mm POREN FIXINGS FOR 40mm CAVITY BATTENS or75mm FIXINGS FOR H3.1 CAVITY SPACERS
STO PREMESHED PVCADJUSTABLE CORNER ANGLESAT EXTERNAL CORNERS
OVERLAY OF STO FLEXYLMEMBRANE UNDER MESHCOAT TO TOP & SIDES, 75mmMIN.DOWNTURN OVER BASECOAT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO POREN SYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
BALUSTRADE/ENCLOSED DECK DETAIL
PP 1021
2014
140
140
WALL UNDERLAY
NOTE:POREN PANEL CAP BUTTS INTO FRAMING AND ISSEALED & TAPED TO UNDERLAY WITH 50x50mmFLASHING TAPE. FLASHING TAPE ONTO THE SEALEDPOREN PANEL MUST BE 50mm MIN.
INSTALL 150mm FLASHINGTAPE 75x75mm EACH WAY
OVER UNDERLAY TOINTERNAL CORNERS
STO CAVITY BATTENS
POREN CAP BUTTS AGAINSTFRAME, PRIOR TO INSTALLINGCAVITY BATTENSPOREN CAP EXTENDS OVERTOP OF SIDE PANELSH3.1 TIMBER PACKER WITH15mm PLYWOOD OVERTIMBER PACKER FLASHINGTAPE or ROOFING UNDERLAY
POREN SIDE PANELS
CAVITY BATTENS or H3.1TIMBER SPACERS
FLASHING TAPE PORENCAP TO UNDERLAY
PARAPET FRAMING
10°WALL UNDERLAYCONTINUOUSOVER TOP OF WALL FRAME
POREN PANELSTO POREN PLASTERSYSTEM
POREN FIXING
OVERLAY OF STO FLEXYLMEMBRANE UNDER MESHCOAT TO TOP & SIDES,75mm MIN.DOWNTURNOVER BASE COAT
STO PREMESHED uPVCADJUSTABLE CORNERS
H3.1 CAVITY SPACER or40mm CAVITY BATTEN
STOFLEXYL MESHED SADDLEMEMBRANE
75POREN CAP AT
10° OVERSEATSWALLS, GLUE TO
POREN WALLCLADDING
H3.1 PACKERCUT TO 10°
SLOPE WITH15mm PLYWOODWITH FLASHING
TAPE ORROOFING
UNDERLAY
75
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
FLEXIBLE FLASHING INSTALL
PP 1022
2014
NOTE: SADDLE FLASHING INSTALLED AFTER CAVITY
SYSTEM. 50x50mm INTERNAL CNR FLASHING FROM
BEHIND SADDLE EXTENDED TO BOTTOM OF WALL
PANELS ON EACH BUILDING FACE
STO 20mm VH CAVITY
BATTENS
PLACE CAP FLASHING OVER
SADDLE FLASHING - REFER TO
E2/AS1 FIGURE 12 FOR CAP FIXING
DETAILS.
H3.1 CAPPING PLATE CUT TO A
FALL WITH FLASHING TAPE OR
ROOFING UNDERLAY
WALL UNDERLAY
2 LINES OF
SEALANT
1
0
0
m
m
M
I
N
.
5
0
m
m
M
I
N
.
50m
m M
IN
.
A. SADDLE FLASHING B. PARAPET CAP
METAL PARAPET CAP
FLASHING
RIVET THROUGH TOP OF CAP TO
SADDLE FLASHING. MS SEALANT
TO RIVETS
EXTENT OF SADDLE FLASHING
8mm EXPANSION GAP BETWEEN
PARAPET CAP AND SADDLE
FLASHING - USE MS SEALANT
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
METAL SADDLE FLASHING
PP 1023
2014
SCALE 1:10
WALL UNDERLAY
POREN PANEL
STO FLEXYL MESHEDWATERPROOFING MIN 75mm OVERADJACENT WALLS.
POREN BALUSTRADECAP AT 10° SLOPE
STO POREN MESHEDBASECOAT PLASTER
NOTE: APPLY STOFLEXYL MESHED WATERPROOFING OVERSTOPOREN MESHED BASECOAT PLASTER.
STO FLEXYL MESHED WATERPROOFING HAS BEEN TESTED BY BRANZ TO MEET AS/NZS4858 FOR A WATERPROOFING MEMBRANE AS REQUIRED BY E2/AS1
75mm MIN.DOWNTURN
H3.1 TIMBER PACKER CUTTO 10° SLOPE
POREN BALUSTRADE CAPLAPS OVER POREN AT SIDES
POREN PANEL AT SIDES
STO CAVITY BATTENOR TIMBER SPACERS
95
95
A. NZBC - E2/AS1 REQUIRES BALCONY & PARAPET WALLS TO BEOFFSET FROM THE MAIN WALL PLANE TO ALLOW FOR SADDLEFLASHINGS
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
STOFLEXYL MESHED SADDLE FLASHING
PP 1024
2014
PRE-FINISHED METAL ROOFINGOVER ROOF UNDERLAY
PREFABRICATED TRUSS TOPCHORD OVERHANG
H3.1 PRE PRIMED &PAINTED FASCIABOARD
SCALE 1:10
SOFFIT LINING TOCLOSE OFF CAVITY MS SEALANT 6-8mm
(before plastering)
WALL UNDERLAYPOREN PANEL
STO POREN PLASTERSYSTEM
H3.1 CAVITY SPACER or 40mmCAVITY BATTEN
NOTE:REFER TO E2/AS1 TABLE 1 FOR DEFINITIONS of RISK LEVELS.EAVE FLASHINGS ARE REQUIRED WHEN FASCIA IS 100mm orLESS FROM EXTERIOR WALL CLADDING & ROOF SLOPES ARE10° or LESS & VERY HIGH/EXTRA HIGH WIND ZONES.USE 120mm POREN FIXINGS FOR 40mm CAVITY BATTENS and75mm FIXINGS FOR H3.1 CAVITY SPACERS
Varies
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
RAKING SOFFIT/WALL JUNCTION
PP 1025
2014
NOTE:REFER TO E2/AS1 TABLE 1 FOR DEFINITIONS of RISK LEVELS.EAVE FLASHINGS ARE REQUIRED WHEN FASCIA IS 100mm orLESS FROM EXTERIOR WALL CLADDING & ROOF SLOPES ARE10° or LESS & VERY HIGH/EXTRA HIGH WIND ZONES.USE 120mm POREN FIXINGS FOR 40mm CAVITY BATTENS and75mm FIXINGS FOR H3.1 CAVITY SPACERS
SCALE 1:10
Varies
6mm
The information contained in this detail is based on our experience and testing and represents the latest information available at the date ofissue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to beused in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is theresponsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO PORENSYSTEM
STO POREN PANEL (40mm cavity) SYSTEM
FLAT SOFFIT/WALL JUNCTION
PP 1026
2014
Recommended