DESCRIPTION

The UTE Speed-O-Calibration Unit (SOC) is used to calibrate the locomotive speedometer. This presentation is an operations outline for Ultra-Tech model 16470-00. Caution:. - PowerPoint PPT Presentation

Citation preview

The UTE Speed-O-Calibration Unit (SOC) is used to calibrate the locomotive speedometer. This presentation is an operations outline for Ultra-Tech model 16470-00.

Caution:

The Operator of this equipment must know and follow general safety procedures concerning electrical and mechanical equipment or be supervised by a qualified trainer.

Setup: Measure and make note of locomotive wheel diameter. The locomotive’s axle alternator is then removed and connected to the Speedometer Calibration Unit (SCU).

Insert and finger-tighten two bolts (as shown).

Open Control Box and confirm that switch is OFF and control is fully counter clockwise.

Attach cable connectors: The connector with the yellow power cable connects to the control box.

The main case uses the connector without the yellow power cable.

Power is normally supplied by connecting the SCU clips to the locomotive DC supply; a workbench supply can also be used (as shown). Observe proper polarity.

If polarity is reversed, unit will appear to be dead (no power).

Confirm the setup procedure before power up.

- Locomotive axle alternator connected to the SCU.

- Cable connectors correctly attached.

- Power supply properly connected (approx. 72V DC).

- Speed control set to minimum (counter clockwise).

Power Up:

Turn power switch ON and allow the SCU control software to get to the main menu.

Push buttons will light to help show available options.

Follow the displayed instructions.

Select for “WhDia” wheel diameter.

INCR (increase) or DECR (decrease) the displayed wheel diameter.

Select ENTER when displayed wheel diameter equals measured diameter.

The top line display should now show the selected wheel diameter and the default target speed.

Operation:

Auto Mode – If auto mode is selected, the speed control must stay at

the home position (completely counter clock-wise).

The target speed can be changed by pushing the INCR or DECR buttons.The SCU will automatically adjust the axle alternator to the targeted test speed.

Manual Mode – If manual mode is selected, the speed control is manually adjusted until the top line speed is nearly equal to the bottom line speed (target speed).

Speedometer calibration is usually done in AUTO mode.

In either mode:

- The axle alternator speed is adjusted to match the target speed (manually or automatically).

- The target speed can be changed by pushing the INCR or DECR buttons.

- Speed is measured in MPH.- The axle alternator speed will flash when it is

more than 1 mph different than the target speed.

Note: The axle alternator speed must be adjustable to be within FRA tolerances!

+/- 3 MPH for 20 & 22 MPH +/- 5 MPH for 40, 60, 72 & 75 MPH.

Auto Mode Operation:

After following the setup and power up procedures, select auto mode.

The back button can be used to get back to previous menus.

Confirm speed control is at minimum (counter clock-wise). Push “Done” button to continue.

Increase or decrease target speed.

Encoder speed adjustments are to be within tolerance at each target speed.

Target speed is on the bottom line of the display.

Power Down:

Minimize speed control and turn OFF power switch.

Conclusion:

This is the end of this presentation.

If you want more information, please see the Instruction and Operations manual 16470-99.