ViSea-DAS Survey Toolbox &

Plume Detection Toolbox(Introduction)

Jeroen AardoomAqua Vision BV

Theoretical introduction

Practical data acquisition & calibration

ADCP measures:water velocity

ADCP measures:water velocity

ADCP measures:water velocity

ADCP measures:Relative Backscatter(echo strength)

ADCP measures:Relative Backscatter

Provides:spatial overview

ADCP measures:Relative Backscatter

Provides:spatial overview

ADCP measures:Relative Backscatter

Provides:spatial overview3-D

ADCP measures:Relative Backscatter

Provides:spatial 3D overview

Disadvantage:qualitative, no SSC (mg/l)

The Challenge:Quantify SSC, in Real-Time

Correct for signal losses:range&instrument normalizationwater absorptionsediment absorption

The working equation (Deines)

Sv normalized backscatter [dB]

C constant [dB]

TT temperature of the transducer [°K]

R slant range along the beam [m]

L transmit pulse length [m]

PT transmit power [W]

aw water absorption [dB/m]

as particle attenuation [dB/m]

Kc RSSI scale factor [dB/count]

E echo intensity [count]

Er received noise [count]

)()(log102

10 rcsw

T

Tv EEKR

LP

RTCS

VISEA-DAS Survey & Plume Detection Toolbox

VISEA-DAS Survey & Plume Detection Toolbox

Converts backscatter to SSCAcquires the data Real TimeAll data within 1 format & timestamp

VISEA-DAS Survey & Plume Detection Toolbox

ViSea-DAS

VISEA-DAS Survey & Plume Detection Toolbox

Survey & Plume Detection Toolbox

Correlation / calibration

OBSRaw data : Volt/Ampere

Is converted -> NTU water samples calibration -> SSC mg/l

ADCPRaw data : Relative Backscatter

Is converted -> Absolute Backscatterwater samples calibration -> SSC mg/l

Correlation / calibration

OBS (NTU) ADCP (IdB)Calibration

Onboard vessel / Real Time

CalibrationSensor Setup

3 Profile/calibration measurements

Cross section/Transects measurements

Typical sample/measuring scheme

Typical sample/measuring scheme

3 Profile/calibration measurements

Typical sample/measuring scheme

3 Profile/calibration measurements

Correlation / calibration

OBS (NTU) ADCP (IdB)Calibration

Onboard vessel / Real Time

Typical sample/measuring scheme

Every hour

3 Profile/calibration measurements

Typical sample/measuring scheme

3 Profile/calibration measurements

Correlation / calibration

Samples (mg/l)

OBS (NTU) ADCP (IdB)

Calibration Calibration

Cross validation

Post processing / analysis

Every hour

3 Profile measurements

Every hour

3 Profile measurements

• Transect measurements

Estuary - hourly calibration

Recommended