DCPNRC 002827March 19, 2010
ENCLOSURE 4
Westinghouse Non-Proprietary
WCAP- 17028-NP
"Evaluation of Debris-Loading Head-Loss Tests for AP1000 Fuel AssembliesDuring Loss of Coolant Accidents," Revision 5
0481ijb.doc
Westinghouse Non-Proprietary Class 3
WCAP-17028-NP March 2CAPP-MY03-T2C-004Revision 5
Evaluation of Debris-LoadingHead-Loss Tests for APIO00 T M
Fuel Assemblies During Lossof Coolant Accidents
Westinghouse
)10
WESTINGHOUSE NON-PROPRIETARY CLASS 3
WCAP-17028-NPAPP-MY03-T2C-004
Revision 5
Evaluation of Debris-Loading Head-Loss Tests for AP1000TM
Fuel Assemblies During Loss of Coolant Accidents
K. L. Ruth*S. L. Baier*
Systems & Equipment Engineering I
T. L. SchulzY. J. SongJ. P. Pezze
AP 1000 Nuclear Systems Engineering
G. ScaddozzoAnsaldo Nucleare
W. A. ByersMaterials Center of Excellence
March 2010
Approved: Timothy D. Croyle, Manager*Systems & Equipment Engineering I
*Electronically approved records are authenticated in the electronic document management system.
Westinghouse Electric Company LLCP.O. Box 355
Pittsburgh, PA 15230-0355
©2010 Westinghouse Electric Company LLCAll Rights Reserved
WCAP-17028-NP
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
RECORD OF REVISIONS
Revision Date Description
0 February 2008 Original
1 July 2009 Revision bars are not included in this document because thisrevision supersedes the original document in its entirety.
2 September 2009 This revision provides clarification on the licensing basisdebris load and limiting case. Identified errors in Tables 4-2,5-1, 6-3 and 9-1 have been corrected. Revision bars areprovided for all changes to this revision,
3 December 2009 This revision contains sixteen FA tests that supplement theinformation provided in all previous revisions ofWCAP-17028-P.
This revision confirms the licensing basis for the reasonableassurance of LTCC under core debris loading conditions forthe AP 1000.
This revision supersedes all previous revisions.
Executive Summary: Minor editorial revisions
Section 1: Minor editorial revisions
Section 2: Minor editorial revisions
Section 3: Minor editorial revisions
Section 4: Minor editorial revisions
Section 5: New Section
Section 6: Major Revision
Section 7: Major Revision
Section 8: Major Revision
Section 9: Major Revision
Section 10: Minor editorial revisions
Section 11: Minor editorial revisions
Appendix A: No Change
Appendix B: No Change
Appendix C: Updated
Appendix D: New
Appendix E: New
Revision 5 iii
Revision 5 iii
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
RECORD OF REVISIONS (cont.)
Revision, Date Description
4 February 2010 This revision contains nine new FA tests plus the existingsixteen FA tests from Revision 3 that supplement theinformation provided in all previous revisions of WCAP-17028-P.
This revision confirms the licensing basis for the reasonableassurance of LTCC under debris loading conditions of the
AP 1000.
This revision supersedes all previous revisions.
Executive Summary: Minor editorial revisions
Section 1: Minor editorial revisions
Section 2: Minor editorial revisions
Section 3: Minor editorial revisions
Section 4: Major Revision
Section 5: Major Revision
Section 6: Minor Revision
Section 7: Major Revision
Section 8: Major Revision
Section 9: Major Revision
Section 10: Minor editorial revisions
Section 11: Minor editorial revisions
Appendix A: No Change
Appendix B: No Change
Appendix C: Updated
Appendix D: No Change
Appendix E: No Change
Revision bars are not included in this revision ofWCAP-17028-P since changes were excessive.
5 March 2010 The purpose of this revision is to correct editorial discrepanciesbetween WCAP-17028-P Revision 4 and WCAP-17028-NPRevision 4.
The technical content in this document has not changed fromRevision 4. Revision bars are not included since changes wereonly editorial and minor.
iv Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
ACKNOWLEDGEMENTS
The support of the Science and Technology Center technicians Allan Neville, Michael Peck, Robert Rees,and Michael Ruffner is gratefully acknowledged.
Revision 5 V
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
TABLE OF CONTENTS
RECORD OF REVISIONS ......................................................................................................................... iii
ACKNOW LEDGEM ENTS .......................................................................................................................... v
L IS T O F TA B L E S ....................................................................................................................................... x i
L IS T O F F IG U R E S ................................................................................................................................... x iii
LIST OF ACRONYMS, ABBREVIATIONS, AND TRADEMARKS ......................................... xix
EXECUTIVE SUM M ARY ........................................................................................................................ xxi
I BACKGROUND .......................................................................................................................... 1-1
O B JE C T IV E .................................................................................................................................. 2 -1
3 A P P R O A C H ................................................................................................................................. 3 -1
4 DESCRIPTION OF EXPERIM ENTAL APPARATUS ................................................................ 4-1
4.1 COM PONENTS USED IN HEAD-LOSS TESTING ..................................................... 4-1
4.1.1 Physical Components ...................................................................................... 4-1
5 ACCEPTANCE CRITERION ...................................................................................................... 5-1
5.1 ACCECPTANCE CRITERA FOR SEQUENTIAL AND CONCURRENT DEBRIS
ADDITIONS FOR COLD-LEG TESTS ......................................................................... 5-2
5.1.1 Sequential and Concurrent Debris Additions Acceptance Criteria
(First Acceptance Criteria) .............................................................................. 5-2
5.1.2 Concurrent Debris Additions Acceptance Criteria (Second Acceptance
C riteria) ........................................................................................................... 5 -4
5.2 DP/FLOW DEPENDENCE RELATIONSHIP ................................................................. 5-5
6 DEBRIS PREPARATION .............................................................................................................. 6-1
6.1 PARTICULATE ............................................................................................................... 6-1
6 .2 F IB E R S ............................................................................................................................ 6 -1
6.3 CHEM ICAL PRECIPITATES ......................................................................................... 6-2
6.4 DEBRIS LOADS ............................................................................................................. 6-2
7 TEST M ATRIX AND INITIAL CONDITIONS .......................................................................... 7-1
8 T E S T R E S U LT S ........................................................................................................................... 8-1
8.1 SUM M ARY OF AP 1000 FA TESTING .......................................................................... 8-1
8.2 TEST# I (CIBAPO 1) ........................................................................................................ 8-6
8.3 TEST #2 (CIBAP02) ........................................................................................................ 8-8
8.4 TEST #3 (CIBAP03) ...................................................................................................... 8-10
8.5 TEST #4 (CIBAP04) ....................................................................... .............................. 8-12
8.6 TEST #5 (CIBAP05) ...................................................................................................... 8-14
Revision 5 vii
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
TABLE OF CONTENTS (cont.)
8.7 TEST #6 (CIBA P06) ......... ............................................................................................ 8-16
8.8 TEST #8 (CIBA P08) ...................................................................................................... 8-18
8.9 TEST #9 (CIBA P09) ..................................................................................................... 8-20
8.10 TEST #10 (CIBA P10) .................................................................................................... 8-22
8.11 TEST #11 (CIBA P11) .................................................................................................... 8-24
8.12 TEST #13 (CIBA P13) .................................................................................................... 8-26
8.13 TEST #14 (CIBA P14) ....... : ............................................................................................ 8-29
8.14 TEST #15 (CIBA P15) .................................................................................................... 8-31
8.15 TEST #16 (CIB A P16) .................................................................................................... 8-33
8.16 TEST #17 (CIBA P17) .................................................................................................... 8-39
8.17 TEST #18 (CIBA P18) .................................................................................................... 8-42
8.18 TEST #19 (CIBA P19) .................................................................................................... 8-44
8.19 TEST #20 (CIBA P20) .................................................................................................... 8-46
8.20 TEST #21 (CIBA P21) .................................................................................................... 8-48
8.21 TEST #22 (CIBA P22) .................................................................................................... 8-50
8.22 TEST #23 (CIBA P23) .................................................................................................... 8-52
8.23 TEST #24 (CIBA P24) ................................ ................................................................... 8-54
8.23.1 Varying Initial Flow Rates ............................................................................. 8-55
8.24 TEST #25 (CIBAP25) .................................................................................................... 8-61
8.25 TEST #26 (CIBA P26) .................................................................................................... 8-63
8.26 TEST #27 (CIBAP27) .................................................................................................... 8-65
8.27 TEST #28 (CIBA P28) .................................................................................................... 8-72
8.28 TEST #29 (CIBAP29) .................................................................................................... 8-74
8.29 TEST #30 (CIBA P30) .................................................................................................... 8-76
8.30 TEST #31 (CIBA P31) .................................................................................................... 8-82
8.31 TEST #32 (CIBA P32) .................................................................................................... 8-84
8.32 TEST #33 (CIBA P33) .................................................................................................... 8-86
8.33 TEST #34 (CIBA P34) ................................................................................................... 8-88
8.34 TEST #35 (CIBA P35) .................................................................................................... 8-93
8.35 TEST #36 (CIBA P36) .................................................................................................... 8-95
8.36 TEST #37 (CIBAP37) .................................................................................................. 8-100
8.37 TEST #38 (CIBA P38) .................................................................................................. 8-102
8.38 TEST #39 (CIBA P39) .................................................................................................. 8-110
8.39 PRESSURE DIFFERENTIAL WITH FLOW ............................................... 8-115
8.39.1 Variation of dP with Variation of Flow and End-of-Test Data ..................... 8-115
8.39.2 Bed Stability D uring Flow Sw eeps .............................................................. 8-120
8.39.3 Basis for the D eveloped Correlation ........................................................... 8-122
8.40 IN VA LID ATED TESTS .............................................................................................. 8-132
9 CON CLU SIO N S .......................................................................................................................... 9-19.1 TEST PRO GRA M SUM M A RY ...................................................................................... 9-1
9.1.1 Latent Fiber Length ......................................................................................... 9-5
9.1.2 Chemical Addition Rate ......................................................... 9-79.1.3 D ebris Q uantities .................................................. ...................................... 9-8
viii Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
TABLE OF CONTENTS (cont.)
9.1.4 F low V ariations .............................................................................................. 9-10
9.1.5 D ebris A ddition Sequence ............................................................................. 9-11
9.1.6 Coolant Chem istry and Temperature ............................................................. 9-12
9.1.7 Effect of Debris Addition with Different Break Scenarios (Hot-Leg vs.
C o ld -L eg) ...................................................................................................... 9 -14
9.2 APPLICABILITY OF TESTING TO AP 1000 DESIGN ............................................... 9-16
10 SU M M A R Y ....................................... .................................... ............................................... 10-1
11 R E F E R E N C E S ........................................................................................................................... 11-1
APPENDIX A APP-FAO1-TIP-001 REVISION 0: TEST PLAN FOR AP1000 DEBRIS
LOADING HEAD-LOSS ACROSS FA .................................................................... A-i
APPENDIX B APP-FAO1-T1P-001 REVISION 1: TEST PLAN FOR AP1000 DEBRIS
LOADING HEAD-LOSS ACROSS FA .................................................................... B-i
APPENDIX C TEST PROCEDURES FOR AP1000 DEBRIS LOADING HEAD-LOSS
A C R O S S FA ................................................................................................................... C -1
APPENDIX D DEBRIS PREPARATION .......................................................................................... D-1
APPENDIX E TEST FACILITY OVERVIEW ................................................................................... E-1
Revision 5 ix
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
LIST OF TABLES
Table 4-1 Instrumentation for Debris Loading Head-loss Testing ................................................... 4-8
Table 4-2 AP1000 Licensing Basis Latent Debris Load ................................................................ 4-10
Table 5-1 Values of the Exponent 'b' to be used in Equation (5.1.1) ............................................... 5-3
Table 5-2 Exponent 'b' Obtained by Best Fit of the Experimental Data from the Tests
Performed with Oscillating Flow Rates and Sequential Additions (P/F/C) ..................... 5-7
Table 5-3 Exponent 'b' Obtained by Best Fit of the Experimental Data from the Tests
Performed with Sequential Debris Additions (P/F/C) from Section 5.1.1 ....................... 5-7
Table 5-4 Exponent 'b' Obtained by Best Fit of the Experimental Data from the TestsPerformed with Coincident Debris Additions from Section 5.1.2 ................................... 5-7
Table 6-1 Original vs. Current AP 1000 Post-LOCA Debris Load Design Basis ............................. 6-3
Table 7-1 Initial Conditions ofAP1000 FA Head-Loss Tests CIBAPOI through CIBAP10 ........... 7-3
Table 7-2 Initial Conditions of AP 1000 FA Head-Loss Tests CIBAP 1I through CIBAP20 ............ 7-4
Table 7-3 Initial Conditions of AP 1000 FA Head-Loss Tests CIBAP21 through CIBAP30 ........... 7-5
Table 7-4 Initial conditions of AP 1000 FA Head-Loss Tests CIBAP31 through CIBAP39 .......... 7-6
Table 8-1 Summary of AP 1000 Fuel Assemblies Head-Loss Tests ................................................. 8-3
Table 8-2 Fibrous Debris M ix Used in Test CIBAP 11 ................................................................... 8-24
Table 8-3 Sensitivity Analysis on the Exponent for Type 2 Tests ................................................ 8-126
Table 8-4 Probability to Exceed Acceptance Criteria, 95% UB Standard Deviation ................... 8-126
Table 8-5 Test Results and dP Adjusted at 5.3 gpm for Comparison Against the
Second A cceptance C riterion ....................................................................................... 8-130
Table 9-1 AP1000 Fuel Debris Tests Scaled Results ....................................................................... 9-2
Table 9-2 Scaled Maximum dP at Flow Prior to 9 Hours for Concurrent Addition Tests ................ 9-4
Revision 5 xi
Revision 5 xi
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
LIST OF FIGURES
Figure 4-1 Schem atic of the Test Loop (Cold-leg Break) .................................................................. 4-3
Figure 4-2 Schematic of the Test Loop (Hot-Leg Break) .................................... ........................... 4-4
Figure 4-3 Schem atic of Test Loop (H eated Test) ............................................................................. 4-5
Figure 4-4 Schematic of Test Loop (Boiling Simulation) ................................................................. 4-6
Figure 5-1 Values of the Exponent 'b' for the Fully Formed Debris Bed, Estimated in
Test CIBAP 08 through CIBAP 11 and CIBAP 18 through CIBAP 34 by a Best Fitof the E xperim ental D ata ................................................................................................. 5-9
Figure 5-2 Distribution of the Exponent for the Fully Formed Debris Bed Estimated in Test
CIBAP 08 through CIBAP 11 and CIBAP 18 through CIBAP 34 ................................... 5-9
Figure 5-3 Coefficient "R" Values for the Fully Formed Debris Bed Estimated in TestCIBAP 08 through CIBAP 11 and CIBAP 18 through CIBAP 34 by a Best Fit
of the E xperim ental D ata ............................................................................................... 5-10
Figure 5-4 Distribution of the Resistance Coefficient for the Fully Formed Debris Bed
Estimated in Test CIBAP 08 through CIBAP 11 and CIBAP 18 through CIBAP 34 .... 5-10
Figure 8-1 Head-Loss and Flow Rate History for Test CIBAPO0 ..................................................... 8-7
Figure 8-2 Head-Loss and Flow Rate History for Test CIBAP02 .............................. 8-9
Figure 8-3 Head-Loss and Flow Rate History for Test CIBAP03 ............................. 8-11
Figure 8-4 Head-Loss and Flow Rate History for Test CIBAP04 ................................................... 8-13
Figure 8-5 Head-Loss and Flow Rate History for Test CIBAP05 ................................................... 8-15
Figure 8-6 Head-Loss and Flow Rate History for Test CIBAP06 ................................................... 8-17
Figure 8-7 Head-Loss and Flow Rate History for Test CIBAP08 ....................... ................... 8-19
Figure 8-8 Head-Loss and Flow Rate History for Test CIBAP09 ................................................... 8-21
Figure 8-9 Head-Loss and Flow Rate History for Test CIBAP 10 ................................................... 8-23
Figure 8-10 Head-Loss and Flow Rate History for Test CIBAP I1 ................................................... 8-25
Figure 8-11 Head-Loss and Flow Rate History for Test CIBAP 13 .................................................. 8-27
Figure 8-12 Concentration of Chemical Debris with Time ............................................................... 8-28
Figure 8-13 Head-Loss and Flow Rate History for Test CIBAP 14 ............................. 8-30
Figure 8-14 Head-Loss and Flow Rate History for Test CIBAP15 ................................................... 8-32
Figure 8-15 Head-Loss and Flow Rate History for Test CIBAP 16 .................................................. 8-34
Figure 8-16 D ebris Load For Test CIBA P16 .................................................................................... 8-35
Figure 8-17 Clean A ssem bly For Test CIBAP 16 ............................................................................... 8-35
Revision 5 XIII
Revision 5 xiii
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
LIST OF FIGURES (cont.)
Figure 8-18 Addition of Particulates for Test CIBAP16 ................................................................... 8-36
Figure 8-19 Accumulation of Fiber at Bottom Nozzle and P-Grid for Test CIBAP 16 ..................... 8-36
Figure 8-20 Debris Bed After Chemical Introduction For Test CIBAP 16 ........................................ 8-37
Figure 8-21 Debris Bed After the Second Chemical Introduction For Test CIBAP16 ...................... 8-37
Figure 8-22 Debris Bed After The Third Chemical Introduction For Test CIBAP 16 ....................... 8-38
Figure 8-23 Debris Bed After Final Chemical Introduction For Test CIBAP 16 ............................... 8-38
Figure 8-24 Head-Loss and Flow Rate History for Test CIBAP 17 ................................................... 8-40
Figure 8-25 Schematic of The Test Loop Configuration For CIBAP 17 ............................................ 8-41
Figure 8-26 Head-Loss and Flow Rate History for Test CIBAP 18 ................................................... 8-43
Figure 8-27 Head-Loss and Flow Rate History for Test CIBAP19 ................................................... 8-45
Figure 8-28 Head-Loss and Flow Rate History for Test CIBAP20 ................................................... 8-47
Figure 8-29 Head-Loss and Flow Rate History for Test CIBAP21 ................................................... 8-49
Figure 8-30 Head-Loss and Flow Rate History for Test CIBAP22 ................................................... 8-51
Figure 8-31 Head-Loss and Flow Rate History for Test CIBAP23 ................................................... 8-53
Figure 8-32 Head-Loss and Flow Rate History for Test CIBAP24 ................................................... 8-55
Figure 8-33 Flow Versus dP During Test CIBAP24 .......................................................................... 8-56
Figure 8-34 Accumulation of Debris at the Bottom of the P-Grid After Second Concurrent
D ebris A ddition in Test C IB A P24 ................................................................................. 8-57
Figure 8-35 Accumulation of Debris at the Bottom of the P-Grid After Third Concurrent
D ebris A ddition in Test CIBA P24 ................................................................................. 8-57
Figure 8-36 Accumulation of Debris at'the Bottom of the P-Grid After Fourth Concurrent
D ebris A ddition in Test CIB A P24 ................................................................................. 8-58
Figure 8-37 Accumulation of Debris Around the Edge of the Bottom Nozzle After
Seventh Concurrent Debris Addition in Test CIBAP24 ................................................. 8-58
Figure 8-38 Accumulation of Debris in the Middle of the First Grid Above the P-Grid After
the N inth A ddition in Test CIBAP24 ............................................................................. 8-59
Figure 8-39 Accumulation of Debris Around the Bottom of the Second Spacer Grid After the
N inth A ddition in Test CIB A P24 ................................................................................... 8-59
Figure 8-40 Accumulation of Debris Around the Bottom Nozzle and P-Grid at the End of Test
C IB A P24 Prior to Flow Sw eeps .................................................................................... 8-60
Figure 8-41 Head-Loss and Flow Rate History for Test CIBAP25 ................................................... 8-62
Figure 8-42 Head-Loss and Flow Rate History for Test CIBAP26 .................................................. 8-64
xiv Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
LIST OF FIGURES (cont.)
Figure 8-43 Head-Loss and Flow Rate History for Test CIBAP27 ........................... 8-66
Figure 8-44 Flow Versus dP during Test CIBAP27 ........................................................................... 8-67
Figure 8-45 Accumulation of Debris Around the Bottom Nozzle and P-Grid after theThird Concurrent Addition in Test CIBAP27 ................................................................ 8-67
Figure 8-46 Accumulation of Debris Around the Bottom Nozzle and P-Grid at theFourth Concurrent Addition in Test CIBAP27 ............................................................... 8-68
Figure 8-47 Accumulation of Debris Around the Bottom Nozzle and P-Grid at theFifth Concurrent Addition in Test CIBAP27 ................................................................. 8-68
Figure 8-48 Accumulation of Debris Around the Bottom Nozzle and P-Grid 30 Minutesinto the Fifth Concurrent Addition in Test CIBAP27 ...................... 8-69
Figure 8-49 Accumulation of Debris Around the Bottom Nozzle and P-Grid 30 Minutesinto the Ninth Chemical Addition in Test CIBAP27 ...................................................... 8-69
Figure 8-50 Accumulation of Debris Around the Bottom Nozzle and P-Grid at the Time of the
Tenth Chem ical Addition in Test CIBAP27 ................................................................... 8-70
Figure 8-51 Accumulation of Debris Around the Bottom Nozzle and P-Grid 30 Minutes into
the Twelfth Chemical Addition in Test CIBAP27 .......................................................... 8-70
Figure 8-52 Accumulation of Debris Around the Bottom Nozzle and P-Grid 15 Minutes After
the Fourteenth Chemical Addition in Test CIBAP27 ..................................................... 8-71
Figure 8-53 Accumulation of Debris Around the Bottom Nozzle and P-Grid Prior to FlowSw eeps in C IB A P 27 ...................................................................................................... 8-7 1
Figure 8-54 Head-Loss and Flow Rate History for Test CIBAP28 ................................................... 8-73
Figure 8-55 Head-Loss and Flow Rate History for Test CIBAP29 ................................................... 8-75
Figure 8-56 Head-Loss and Flow Rate History for Test CIBAP30 ................................................... 8-77
Figure 8-57 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After theThird Concurrent Addition in Test CIBAP30 ................................................................ 8-78
Figure 8-58 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Fourth Concurrent Addition in Test CIBAP30 ............................................................... 8-78
Figure 8-59 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After theFifth Concurrent Addition in Test CIBAP30 ................................................................. 8-79
Figure 8-60 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Ninth Chemical Addition in Test CIBAP30 .................................. 8-79
Figure 8-61 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Twelfth Chem ical Addition in Test CIBAP30 ............................................................... 8-80
Revision 5 XV
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
LIST OF FIGURES (cont.)
Figure 8-62 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Seventeenth Chemical Addition in Test CIBAP30 ........................................................ 8-80
Figure 8-63 Accumulation of Debris at the Bottom Nozzle and P-Grid Near the End of theFlow Sw eeps in Test C IB A P30 ...................................................................................... 8-81
Figure 8-64 Head-loss and Flow Rate History for Test CIBAP31 .................................................... 8-83
Figure 8-65 Head-loss and Flow Rate History for Test CIBAP32 .................................................... 8-85
Figure 8-66 Head-loss and Flow Rate History for Test CIBAP33 .................................................... 8-87
Figure 8-67 Head-loss and Flow Rate History for Test CIBAP34 .................................................... 8-89
Figure 8-68 Accumulation of Debris at the Bottom Nozzle and P-Grid Right before the
Fourth A ddition in Test CIB A P34 ................................................................................. 8-90
Figure 8-69 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes after the
Fourth Concurrent Addition in Test CIBAP34 ............................................................... 8-90
Figure 8-70 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes after the
Ninth Chem ical Addition in Test CIBAP34 ................................................................... 8-91
Figure 8-71 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes after the
Twelfth Chem ical Addition in Test CIBAP34 ............................................................... 8-91
Figure 8-72 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes after the
Last Chem ical Addition in Test CIBAP34 ..................................................................... 8-92
Figure 8-73 Head-loss and Flow Rate History from Test CIBAP35 ................................................. 8-94
Figure 8-74 Head-loss and Flow Rate History for Test CIBAP36 .................................................... 8-96
Figure 8-75 Accumulation of Debris at the p-grid 30 Minutes after the Third Concurrent
A ddition in Test C IB A P36 ............................................................................................ 8-97
Figure 8-76 Accumulation of Debris at the p-grid 30 Minutes after the Ninth Chemical
A ddition in Test C IB A P36 ............................................................................................. 8-97
Figure 8-77 Accumulation of Debris at the p-grid 30 Minutes after the Fifteenth Chemical
A ddition in Test C IB A P36 ............................................................................................. 8-98
Figure 8-78 Accumulation of Debris at :the Third Grid 30 Minutes after Fifteenth Chemical in
T est C IB A P 36 ............................................................................................................... 8-9 8
Figure 8-79 Accumulation of Debris at the p-grid at the End of the Test CIBAP36 ........................ 8-99
Figure 8-80 Data Plot from Test CIBAP37 Baseline dP Corrected to Zero .................................... 8-101
Figure 8-81 Data Plot from Test CIBAP38 Baseline dP Corrected to Zero .................................... 8-103
Figure 8-82 Photograph of the Top-Grid 59 Minutes after the First Concurrent Addition in
T est C IB A P 3 8 .............................................................................................................. 8-104
xvi Revision 5
xvi Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
LIST OF FIGURES (cont.)
Figure 8-83 Photograph of the Top-Grid after Stable Air and Water Flow are Achieved in Test
C IB A P 3 8 ...................................................................................................................... 8-104
Figure 8-84 Photograph of the Top Grid Seconds before Simulating Boiling Began ..................... 8-105
Figure 8-85 Photograph of the Top Grid 6 Seconds after Simulated Boiling Began ....................... 8-105
Figure 8-86 Photograph of the Top Grid 12 Seconds after Simulated Boiling Began ..................... 8-106
Figure 8-87 Photograph of the Top Grid 19 Seconds after Simulated Boiling Began ..................... 8-106
Figure 8-88 Photograph of the Top Grid 24 Seconds after Simulated Boiling Began ............. ........ 8-107
Figure 8-89 Photograph of a Spacer 51 Minutes after First Addition (SiC) During Up-flow in
T est C IB A P 38 .............................................................................................................. 8-107
Figure 8-90 Photograph of the Top-Grids 51 Minutes after First Addition (SiC) During
U p-flow in Test C IB A P38 ............................................................................................ 8-108
Figure 8-91 Photograph of the Top-Grid 51 Minutes after First Addition (SiC) During
U p-flow in Test C IB A P38 ........................................................................................... 8-108
Figure 8-92 Photograph of the p-grid after Flow Sweeps in Test CIBAP38 ................................... 8-109
Figure 8-93 Data Plot from Test CIBAP39 Baseline dP Corrected to Zero .................................... 8-111
Figure 8-94 Photograph of the Spacer Grid 34 Minutes after the First Concurrent Addition in
T est C IB A P 39 .............................................................................................................. 8-112
Figure 8-95 Photograph of the Spacer Grid 34 Minutes after the Second Concurrent Addition
in T est C IB A P 39 .......................................................................................................... 8-112
Figure 8-96 Photograph of the Spacer Grid 30 Minutes during Water and Air Flow
Stabilization for 60 Minutes after the Last Chemical Addition ................................... 8-113
Figure 8-97 Photograph during Water and Air Flow Stabilization for 60 Minutes after the
L ast C hem ical A ddition ............................................................................................... 8-113
Figure 8-98 Photograph of the Top-Grid during Water and Air Flow Stabilization for
60 M inutes after the Last Chem ical Addition .............................................................. 8-114
Figure 8-99 Photograph of the Spacer Grid during the Last Flow Profile in Test CIBAP39 ......... 8-114
Figure 8-100 dP Versus Flow For Test CIBAP09 .............................................................................. 8-116
Figure 8-101 dP Versus Flow For Test CIBAPIl .............................................................................. 8-117
Figure 8-102 dP First and Last Flow Cycle in Test CIBAP 11 .......................................................... 8-117
Figure 8-103 dP Versus Flow For Test CIBAP20 .............................................................................. 8-118
Figure 8-104 dP Versus Flow For Test CIBAP21 .......................................... ................................ 8-118
Figure 8-105 dP Versus Flow For Test CIBAP25 .............................................................................. 8-119
Revision 5 xvii
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
LIST OF FIGURES (cont.)
Figure 8-106 dP Versus Flow For Test CIBAP26 .............................................................................. 8-119
Figure 8-107 dP Versus Flow For Test CIBAP30 .............................................................................. 8-120
Figure 8-108 dP Versus Flow for Test CIBAP20 ............................................................................... 8-121
Figure 8-109 dP Versus Flow during the First and the Last Part of the Flow Sweeps in
T est C IB A P 18 .............................................................................................................. 8-122
Figure 8-110 Evolution of the dP-Flow Relationship during Test CIBAP 34 ................................... 8-127
Figure 8-111 Evolution of the Exponent and Coefficient Characterizing the dp-Flow
Relationship during Test CIBA P 34 ............................................................................. 8-127
Figure 8-112 Comparison Between the Measured DP and the DP Adjusted at [ ]aC gpm for
T est C IB A P 34 ............................................................................................................. 8-128
Figure 8-113 Comparison Between the Measured DP And the DP adjusted at [ ]a,C gpm for
T est C IB A P 30 .................. ......................................................................................... 8-12 8
Figure 9-1 AP1000 Fuel Debris Tests Scaled Results ....................................................................... 9-4
Figure 9-2 Fibers Photographed Near the End of Test CIBAP 11..................................................... 9-6
Figure 9-3 Resident Fibers Collected from Plant B Described in NUREG/CR 6877 ....................... 9-7
Figure 9-4 Comparison of Tests at [ ] with Boric Acid and TSP to Room Temperature
W ater T ests ..................................................................................................................... 9 -13
Figure 9-5 A P 1000 FA Schem atic ................................................................................................... 9-16
xviii Revision 5
xviii Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
LIST OF ACRONYMS, ABBREVIATIONS, AND TRADEMARKS
ADS automatic depressurization system
DBA design basis accident
DCD design control document
DECL double-ended cold-leg
dP differential pressure
DVI direct vessel injection
ECCS emergency core containment system
FA fuel assembly
IOZ inorganic zinc
IRWST in-containment refueling water storage tank
LOCA loss of coolant accident
LTCC long-term core cooling
MRI metal reflective insulation
NRC United States Nuclear Regulatory Commission
P/F particulate to fiber ratio
PWR pressurized water reactor
PXS passive safety system
QMS Westinghouse Quality Management System
RAI request for additional information
RCS reactor coolant system
SCFM standard cubic feet per minute
SER safety evaluation report
STC Westinghouse Science and Technology Center
TSP trisodium phosphate
ZOI zone of influence
Revision 5 xix
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
EXECUTIVE SUMMARY
Westinghouse performed a series of experiments to quantify the effect of fibrous and particulate debris
and containment chemical reaction products on the head-loss across the fuel assemblies of an AP IOOOTMI
pressurized water reactor (PWR) during a postulated loss of coolant accident (LOCA). These
experiments were conducted in consideration of Generic Safety Issue 191 (GSI-191), "Assessment of
Debris Accumulation on PWR Sump Performance" (Reference 1). This report documents the results of
the FA head-loss experiments.
The experiments were performed at the Westinghouse Science and Technology Center (STC) in
Churchill, PA. The fuel assembly (FA) design used in testing is consistent with the FA design described
in subsection 4.2.2.2 of the AP1000 Design Control Document (DCD) (Reference 2). The flow rates and
debris loadings and method of debris addition were varied from test to test. The goal of the testing was to
select a combination of debris variables and simulated plant variables that would bound any AP 1000
LOCA as defined in Reference 2, and to demonstrate that the APO0O debris load will not impede long-
term core cooling (LTCC). At the onset of the program it was not clear which conditions would produce
the highest head-losses and so, a spectrum of different flow rates, debris quantities, debris types, methods
of debris addition and other experimental variables were explored to ensure that the most challenging
conditions were tested. For the cold-leg break scenario, initial flow rates between
a,c
All cold-leg break tests produced FA head-losses that were well within the calculated head-loss limit
established for the AP1000 in Reference 3. This was true for all combinations of variables. Maximum
AP1000 debris loads per assembly [
]ac The hot-leg break tests showed that if boiling is present in the
core as would be expected, the formation of continuous debris beds will be disrupted and pressure drop
increases in the upper core due to debris will be [ ]c
These experiments demonstrate that the AP 1000 design provides for a considerable margin in the cooling
analysis of the AP 1000, (Reference 3), and has shown that the core will continue to be cooled with a
head-loss of 4.1 psid (at a corresponding flow rate of 65.0 lbm/s) across the core for a cold-leg break.
The long-term experimental head-loss values were considerably lower than 4.1 psid when flows were
corrected to 65 lbm/s. The long-term cooling analysis of the AP1000 (Reference 3 Case #11) has shown
that the core will continue to be cooled with a < 2 psid head-loss at the top of the core with a
corresponding flow rate of 214.5 lbm/s. The experimental head-losses for the hot-leg break scenario were
considerably lower than [ ]a"c
1. AP 1000 is a trademark of the Westinghouse Electric Company LLC.
Revision 5 xxi
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The debris loads in the test program were considerably below the debris loads used in GSI-191 testing for
operating plants because debris-load for the AP1000 has been significantly reduced by design. This is
true for all three types of debris that must be considered in the evaluation of LTCC: fibrous debris,
particulate debris, and solids produced by containment chemical reactions. As presented in Reference 2,
the AP 1000 design is engineered to reduce the potential for head-loss during long-term cooling operation:
The AP 1000 design eliminates the generation of fibrous debris following a LOCA. The small
amount of fibrous debris present in the resident debris is assumed to transport to the screens or to
the core;
Resident (latent) debris is the only source of fibers in an AP1000;
The AP1000 design reduces the generation of post-accident chemical effects debris;
The good housekeeping practices required by COL item 6.3.8.1 will limit the amount of resident
containment debris;
The AP1000 design has reduced long-term cooling flow rates compared to active emergency core
cooling systems (ECCS) of currently operating PWRs;
The AP 1000 design provides for increased time between the accident and the start of
recirculation, which together with the reduced long-term cooling flow rates, enhances the settling
of debris;
The AP 1000 requires the use of high density epoxy coatings on walls, floors, and structural
surfaces as well as on engineered components. The use of high density epoxy coatings together
with the other AP 1000 features and characteristics prevent failed high density coatings outside the
zone of influence (ZO) from being transported to the screens or core;
The AP 1000 requires signs and tags used inside containment to be made from high density
materials, so that if they are detached they will settle out without being transported to the core;
and
* The AP 1000 incorporates large, advanced screen designs.
xxii Revision 5
xxii Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
1 BACKGROUND
Westinghouse has performed a series of FA head-loss experiments for the AP 1000 in response to NRC
Generic Safety Issue 191 (Reference 1). The purpose of this test program was to quantify the head-loss
across the fuel assemblies during a LOCA considering the debris loadings applicable to the AP1000. The
debris loadings considered fibrous and particulate debris and containment chemical effects applicable to
the AP 1000.
The experiments used a FA design that is consistent with the design described in subsection 4.2.2.2 of the
AP 1000 DCD, (Reference 2). The flow rates and debris loading conditions were selected conservatively
so that they bound those expected following a postulated LOCA for the AP1000 as defined in
Reference 3. Since the fibrous and particulate debris and chemical loadings bound the conditions
calculated for a single AP1000 FA, the data collected from this program is applicable to the whole core.
The evaluation of debris-loading head-loss tests for AP 1000 fuel assemblies during a LOCA have been
presented in all versions of WCAP-17028-P. Each revision of WCAP-17028-P has increased the
knowledge base and understanding of the head-loss across fuel assemblies in the post-LOCAAP 1000.
WCAP-17028-P, Revision 0 consisted of four initial head-loss tests that were performed in 2008 to obtain
data to support resolution of GSI-191 for the AP1000. The results of these tests included what was
first considered to be the bounding resident debris load test, a sensitivity resident debris load test with
oscillating flow, a "super sensitivity" resident debris load test, and a repeat sensitivity resident debris load
test with constant flow rate. All of these tests included chemical products that bounded the chemical
debris load calculated for the AP 1000. Only in the super-sensitivity test was there a measurable increasein pressure drop across the assembly with the addition of debris. After discussions with the U.S. Nuclear
Regulatory Commission (NRC) on the resolution of GSI-191 issues related to the AP 1000, Westinghouse
concluded that the debris loads assumed in the first four tests were insufficient to satisfy the debris
requirements contained in the safety evaluation report (SER) on NEI 04-07 (Reference 4).
WCAP-17028-P, Revision 1 was written to resolve outstanding issues related to the resolution of GSI-191
resulting from the testing reported in WCAP-17028-P, Revision 0. Resident fiber and particulate debris
loads were recalculated to be more in line with the debris loads associated with currently operating plants
(Reference 5). Chemical effects were recalculated based on the revised debris load and aluminum content
in the AP 1000 containment (Reference 5). Twelve tests were conducted utilizing revised debris loads and
chemical effects. These tests included a broader range of fibrous debris types, several variations in the
flow rates, and variation in the method of chemical debris addition. The results of nine of these twelve FA
head-loss tests performed for the AP 1000 were summarized in WCAP-17028-P, Revision 1.
During a meeting to discuss WCAP-17028-P, Revision 1, the NRC pointed out that the WCAP contained
errors; that the results of the three tests that were excluded from WCAP-17028-P, Revision 1 should be
included; that clarification on the licensing basis debris load and limiting case was needed; and that the
assurance of AP 1000 LTCC success would require additional testing to complement and support the work
that had been done to date.
In response to the concems of the NRC regarding the information in WCAP-17028-P, Revision 1,
Westinghouse issued WCAP-17028-P, Revision 2 to correct errors, to provide additional clarification on
Revision 5 1-1
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
the licensing basis debris load and limiting case, and to provide the results of the three tests that were
excluded from WCAP-17028-P, Revision 1. Additionally, Westinghouse developed a test matrix to
address the NRC concerns related to the debris-loading head-loss tests for AP 1000 FAs.
Revision 3 of WCAP-17028-P included data from fourteen additional FA debris tests. WCAP-17028-P,
Revision 3 was written to demonstrate and confirm the assurance of LTCC under debris loading
conditions for the AP 1000. The conditions include a spectrum of plant-specific debris characteristics
including chemical effects in order to satisfy GSI-191.
WCAP- 1 7028-P, Revision 4 was written to include nine additional FA tests performed to respond tospecific requests for additional information (RAIs) issued by the NRC. The nine tests investigatedrepeatability, the hot-leg break scenario with debris entry at the top of the core with changing flowpatterns, the effect of boiling, the effect of elevated temperature, and the effect of the reactor coolantchemicals, trisodium phosphate and boric acid. WCAP-17028-P, Revision 4 presented the results of all39 FA debris test assembly head-loss experiments and summarizes the results of experiments performedwith
]a,c All of the experiments were
performed to demonstrate the margin available in the AP 1000 design. The additional nine FA tests arepresented in Section 8 of this report.
WCAP-17028-P, Revision 5 was written to include editorial changes. The technical content did not
change from WCAP-17028, Revision 4.
These head-loss experiments were performed under the Westinghouse Quality Management System
(QMS) requirements.
1-2 Revision 5
1-2 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
2 OBJECTIVE
This program was designed to demonstrate assurance of LTCC for the AP 1000 in accordance with theNRC guidance provided in GSI-191 and Generic Letter 2004-02. All experiments used in demonstration
of assured long term coolant are to comply with the Westinghouse QMS. Experiments should bound or
be representative of Design Basis Accident (DBA) conditions as specified in Reference 2 for the AP 1000.
Revision 5 2-1
Revision 5 2-1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
3 APPROACH
The test loop, described in detail in test procedures attached in Appendix C of this document, consists of a
single [ ]a"C FA inside a Plexiglas®V case, a mixing tank, and the pumps and plumbing required to
circulate water and debris. The test loop was configured two different ways, one simulating a cold-leg
break and another simulating a hot-leg break.
In order, from top to bottom simulating a cold-leg break, the FA contains
]a"c The [
]a"c just as it would in the actual AP1000 design.
In order, from top to bottom simulating a hot-leg break, the FA contains
]a,c
The test loop simulated two additional condtions; [required additional equipment on the standard FA set up. The
additional heater to heat the coolant in the test loop. The simulateddelivery system and an air flow meter that was added to the test loop.
]aC These tests]a,c test required an
]a,c test required an air
The test loop flow rates were scaled to a [ a,pc to represent the flow rate at the entrance to
the [ pac for a cold-leg break scenario and a hot-leg break scenario. The selected flow rates are
representative of, or bound, the flows that can be expected through the core during the recirculation phase
that follows a LOCA.
The debris loadings that were used in the tests were selected and scaled to bound the amount of debris
that could be transported to the AP 1000 core. The specified debris loadings were tested in the FA test
loop located at the Westinghouse STC. The debris loadings included resident fibrous and particulate
debris and chemical effects. The fibrous and particulate debris load and chemical precipitates were
prepared outside of the test loop and then added to the mixing tank following the test procedures
(Appendix C). All of the experiments included fibrous and particulate debris and chemical reaction
products that were added to the mixing tank as water suspensions.
Plexiglas® is'a registered trademark of Arkema, Incorporated.
Revision 5 3-1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
In prior industry testing programs the manner in which the debris is added was observed to make a
difference in the overall head-loss through the FA. Therefore, the following debris additions schemeswere used:
Sequential additions of particulate, fiber, and chemicals
- For sequential debris addition tests, an aliquot of the water from the mixing tank wasremoved and placed in a container for each addition of particulate. The particulate wasthen well mixed into this water until completely suspended before being added to themixing tank. The mixing tank volume was allowed to
]a,c
- For sequential debris addition tests, the fiber was added following the test plan using a
similar technique to that described above for the particulate. [
a,c
- For sequential debris addition tests, surrogates for chemical reaction products were added
to the test loop after all of the fiber and particulate had been added. As defined in the testplan, the chemical precipitate was mixed outside the test loop per the WCAP-16530-NP-A
(Reference 11) methodology and then added to the test loop in measured batches.
* Concurrent additions of particulate, fiber and chemicals
- For concurrent debris addition tests, an aliquot of the water from the mixing tank wasremoved and placed in a container and the prescribed amounts of particulate and fiber wereadded to the container. The particulate and fiber were then well mixed in this water untilcompletely suspended before being added to the mixing tank. Concurrent with the additionof particulate and fiber, chemical surrogate was added directly to the mixing tank in theamount prescribed in the test procedure. Concurrent debris additions were made at timesspecified in the test procedure.
These approaches to introducing the debris into the test loop (sequential or concurrent) are consistent withthe NRC guidance on head-loss testing issued on March 31, 2008 (Reference 10, Section 6).
"Sequencing the debris for thin bed testing by adding 100 percent of the plant particulate load to the test
flume and subsequently adding fibrous debris in incremental batches of an appropriate size is anacceptable method for performing thin bed testing. Depending on the scaling ratios for the test, thisprocedure may be overly conservative. As an alternative, a series of tests using homogeneous debris
addition is also acceptable provided that a sufficient number of tests is performed to provide confidencethat the limiting thin bed head-loss has been achieved".
3-2 Revision 5
3-2 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The tests could be terminated based on either of the following criteria:
Exceeding the maximum pressure safety limit established for the test facility: or
By meeting the equilibrium criterion determined by calculating the slope in dP across the full FA.
]a,c
Revision 5 3-3
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
4 DESCRIPTION OF EXPERIMENTAL APPARATUS
A complete description of the test loop used in the conduct of the AP1000 debris loading head-loss testing
is included in Section 5 of the test plan provided in Appendix A of this document and will not be repeated
in detail here. Summarized in this section are those items considered important to facilitate an overall
understanding of the testing process.
4.1 COMPONENTS USED IN HEAD-LOSS TESTING
Physical Components
Figure 4-1 presents the loop layout of the AP 1000 debris loading head-loss test facility for a cold-leg
break. Figure 4-2 presents the loop layout of the AP 1000 debris loading head-loss test facility for a
hot-leg break. Figure 4-3 presents the loop layout of the AP 1000 debris loading head-loss test facility
I ]a,c Figure 4-4 presents the loop layout of the AP 1000 debris loading
head-loss test facility [ ]a.C For additional information on the physical arrangement of
the test loop, refer to Section 5 of the test plan provided in Appendix A of this document.
The following components were used in the construction of the test loop at the Westinghouse STC:
Mixing tank system
- [ ]a,c
Recirculation system
- I
]a,c
Test column
- II
c]ac
Computer monitoring system
Mixing Tank System
The mixing tank system includes]a.c The mixing tank is where debris is added during a test. The [
]a•c helps preclude the settling and loss of debris on the bottom of the tank. Therecirculating water in the loop flows out of the [ ]a,c of the tank and into the top of
the tank. The tank water temperature []a,c The water
].C to a high temperature oftemperature can be controlled from a low temperature [
Revision 5 4-1
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
I
pump [of the tank. [
]a C and the temperature of the water is measured continuously in the tank []a.C Mixing of the tank is achieved by the use of a Performance Pro Cascade
]a'c at the top
]a,c
4-2 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Figure 4-1 Schematic of the Test Loop (Cold-leg Break)
Revision 5 4-3
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
Figure 4-2 Schematic of the Test Loop (Hot-Leg Break)
4-4 Revision 5
4-4 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Figure 4-3 Schematic of Test Loop (Heated Test)
Revision 5 4-5
Revision 5 4-5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Figure 4-4 Schematic of Test Loop (Boiling Simulation)
4-6 Revision 5
4-6 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Recirculation System
The recirculation system pumps the water from the tank through the test column and back into the tank. A
Performance Pro Cascade 3/4 HP pump draws the water out of the bottom of the mixing tank. The flow
rate is controlled
]a,c regulates the flow rate to maintain that value. For tests that simulate
]a'c The recirculation system
is in continuous duty to accommodate longer tests.
Test Column
The test column contains the FA and]a,c inside the reactor vessel. Most of the column is made from [ ]a,c
to allow easy viewing of what occurs during testing. The test column is made up of two boxes,]a"C These
two boxes
]a,c
As debris catches on the FA, the dP is measured constantly
]aC At the beginning of the test, the FA is [
]aC The FA is held down by
temperature of the water in the column is measured continuously]a,c
]a c The
Revision 5 4-7
Revision 5 4-7
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
The height of the
]a.C of the FA.
Computer Monitoring System
The computer monitoring system continuously records the following data:
, Temperature of the water in the mixing tank* Temperature of the water in the test column* Flow rate* DP (dP) measurements p,c
This data can be recorded at a time interval chosen by the operator. The computer is also used to
Ia,c
Instrumentation
Table 4-1 gives a listing of instrumentation that was used for the experiments. The following parameterswere monitored and recorded during the head-loss experiments:
* Debris sample mass* Volumetric flow rate* Loop water temperature* Loop pressure drop across the bundle
Table 4-1 Instrumentation for Debris Loading Head-loss Testing
I 4
Note that the test facility ensures that
]apc This conservatively bounds the actual plant conditions because in the event
of a LOCA, debris that passes through the FA will be recirculated through sump screens.
An overview of the test facility complete with pictures of debris preparation and test operation is providedin Appendix E. Prior to the start of each experiment, all of the debris planned for introduction into the testloop was prepared according to procedure. The fiber and particulate were weighed out and the chemicalprecipitate was prepared per WCAP-16530-NP-A procedure (Reference 11). A sample of the chemical
4-8 Revision 5
4-8 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
surrogate was tested to assure that the chemical mix met the settling requirements provided in the
preparation procedure.
Debris Loads
The AP 1000 design minimizes the potential for a LOCA to generate debris that might challenge the core
flow path as discussed in References 2 and 5:
Metal reflective insulation (MRI) is used on components that might be subjected to direct jet
impingement loads; MRI is not transported to the AP1000 Containment Recirculation or in-
containment refueling water storage tank (IRWST) screens due to the relatively low AP 1000 flow
rates during recirculation. The AP1000 design prohibits the use of fiberglass within the ZOI and
as a result no fibrous debris is generated by the LOCA blowdown. All fiberglass insulation in
containment is located outside the ZOI. In addition, any fiberglass insulation used outside the
ZOI is jacketed. As a result, AP1000 does not have any LOCA generated fiber debris.
The AP 1000 containment floods up to a higher level. The deeper flood levels significantly reduce
the velocities that would occur during recirculation operation, thereby minimizing the potential
for debris transport.
The AP 1000 requires the use of high density coatings on walls, floors, and structural surfaces as
well as on engineered components. Note that the use of inorganic zinc (IOZ) coatings inside the
containment is restricted to the inside surface of the containment shell and to components whose
surface temperature exceeds the applicable limit for epoxy coatings. Zinc coatings used inside
containment are required to be safety Service Level I to prevent their failure outside the ZOI. All
coatings located inside the ZOI are assumed to fail as fines and to transport to the screens or the
core.
The AP 1000 requires that signs and tags used inside containment be made from high density
materials so that, if they detach, they will settle out without being transported to the screens.
Protective overhangs prevent heavier debris, including the high density coatings used in the
AP 1000, from falling onto or just in front of the containment recirculation screens and from being
transported to them.
The containment recirculation screens are large with a complex geometry in order to
accommodate collected debris without impacting core flow.
The AP 1000 has several features that significantly reduce the amount of materials that could
contribute to the formation of chemical precipitates. The excore detectors are enclosed in
stainless steel or titanium preventing circulation of post-accident water past the aluminum
detectors. The containment uses a structural steel modular construction which reduces the
amount of concrete that can come in contact with post-accident water. This design minimizes the
production of calcium phosphate by chemical reactions between the buffer agent, trisodiumphosphate (TSP) and concrete post-accident. All concrete surfaces are coated with epoxy.
Revision 5 4-9
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API1000
The AP1000 licensing basis fibrous, particulate, and chemical debris loads that could be transported into
the reactor vessel and possibly reach the fuel assemblies, are presented in Table 4-2. These debris loads
are based on a total debris load of 180 pounds and a chemical debris load of 57 pounds (Reference 5). Of
the 180 pounds of debris, no more than 6.6 pounds may be fiber. The chemical debris load is based on
the type and quantity of chemical precipitates which may form in the post-LOCA recirculation fluid for
the AP1000 design as reported in Reference'5. It is conservatively assumed that 90% of the fiber,
100% of the particulate, and 100% of the chemical debris is transported to the core in the licensing basis
scenario for a cold-leg break case.
Table 4-2 AP1000 Licensing Basis Latent Debris Load
Totals in Containment, Particulate 173.4 lb (78.65 kg)
Fiber 6.6 lb (2.99 kg)
Chemical 57.0 lb (25.85 kg)
Transported to Core, Particulate (100%) 173.4 lb (78.65 kg)
Fiber (90%) 5.94 lb (2.69 kg)
Chemical (100%) 57.0 lb (25.85 kg)
Scaling Considerations
A scaling rationale was used to determine the parameters for
]a,c
The test fixture [ ]ac simulated FA with the [The cross-section of the FA has an [ ]a.C The AP 1000 has[
]'C This results in a total core area of [
]a,c
]a'C The scale factor is
the ratio of the [ ]a,c
[a,c
11 :la,
For determining the mass concentration of debris in the plant, the test facility water mass and the
AP 1000 recirculation mass were used.
II ]a,
I a,c
4-10 Revision 5
4-10 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
Section 4.2 of Reference 9 (attached in Appendix A of this document) presents additional discussion ofscaling considerations used in the FA debris head-loss experiments.
Revision 5 4-11
Revision 5 4-11
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
5 ACCEPTANCE CRITERION
The AP 1000 safety related systems are designed to indefinitely provide cooling to the reactor core
following a LOCA. After the initial injection of water from the core makeup tanks and the accumulators,
the reactor coolant system (RCS) is almost depressurized, and water is injected by gravity drain from the
IRWST. After the IRWST level drops below a specified setpoint, containment recirculation valves are
opened to provide a supply of water for the RCS (Reference 5).
In this recirculation phase, natural circulation provides the driving force; water flowing through the core
cooling the fuel bundles is discharged from the stage 4 of the automatic depressurization system (ADS) in
the containment as a two phase mixture of steam and water. The steam released from the ADS valves is
condensed on the steel surface of the containment vessel, which is cooled on the outside by the passive
containment cooling system. The condensed water drains by gravity into a gutter and is then returned to
the IRWST for injection into the RCS through the direct vessel injection (DVI) lines. The liquid water
flooding the containment is returned to the RCS by the passive safety systems (PXS) containment
recirculation screen and piping. However, due to the high flood-up level of the AP1000 design, water
could bypass the recirculation screens and enter directly into the reactor vessel as in the case located
below the flood level (Reference 5).
With maximum bypass flow, the debris present in the containment may be transported directly into the
RCS and eventually into the core. If a uniform debris bed forms as a result of debris collecting in the
core, the resulting additional resistance may reduce the core flow rate. In order to assess the impact of
additional resistance to flow at the core inlet, a LTCC analysis was performed to determine the minimum
flow/maximum dP (dP') across the core (Reference 3).
Because of the large volume of water that floods the containment and the relatively slow recirculation
flow rate, it will take many hours for the debris to be transported into the RCS.
Using this information, a worst case condition was then postulated assuming that all the debris will reach
the core entrance after one complete recirculation of the entire containment water volume. In this case the
long-term analysis (Reference 3, Case 10) found that for a cold-leg-break, the limiting dP through the
core is 4.1 psid with a corresponding minimum flow rate of 65.0 lbm/s (480.7 gpm core flow rate.)
Using the scale factor discussed in Section 4.1 and the minimum flow rate of 480.7 gpm for a cold-leg
break, the corresponding minimum flow rate for the tests is [ ]ac The acceptance criterion for the
FA tests is that the dP across the FA test article must not exceed 4.1 psid at a flow rate of [ pc
This acceptance criterion of 4.1 psid at a flow rate of [ ]a,C will be applied to each of the cold-leg
break FA tests.
In the event of a hot-leg break LOCA in an AP 1000 the flow in the upper part of the core is expected to
oscillate. When the down-flow in a low-power assembly becomes low, steam generation rises.
The production of steam, together with other thermal hydraulic forces acting on the system, would result
in a change in flow direction from the downward to upward direction.
1. Note that DP, dP, and AP may be used to express the dP in this document.
Revision 5 5-1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
For a hot-leg break, the long-term analysis (Reference 3, Case 11), found that the limiting dP through the
core is 2 psid with a corresponding minimum flow rate of 214.5 lbm/s (1602 gpm core flow rate). This is
the minimum flow rate that can maintain LTCC. Using the scale factor discussed in Section 4.1 and the
minimum flow rate of 1602 gpm for a hot-leg break, the corresponding minimum flow rate for the tests is
I ]a"C The quality of the flow discharged through the ADS-4 flow paths is approximately 0.10.
This was taken into consideration for the corresponding minimum liquid flow rate value. The acceptance
criterion for the hot-leg break FA tests is that the dP across the FA test article must not exceed 2 psid at a
flow rate of [ ]c This acceptance criterion of 2 psid at a flow rate of [ ]aC will be applied to
each of the hot-leg break FA tests.
5.1 ACCECPTANCE CRITERA FOR SEQUENTIAL AND CONCURRENT DEBRIS
ADDITIONS FOR COLD-LEG TESTS
As seen in Table 8-1, many cold-leg tests were performed with a constant flow rate higher than
a,c
To adjust the experimental results to a lower flow rate, the following correlation was adopted:a,c
[ I Equation (5.1.1)
where:
a.c
Herein the following the correlation is adopted for the two acceptance criteria. Its applicability is
separately discussed and justified in Section 8.39.3.
5.1.1 Sequential and Concurrent Debris Additions Acceptance Criteria (First Acceptance
Criteria)
As previously shown, many cold-leg tests were performed with a constant flow rate higher than
5-2 Revision 5
5-2 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
]a,c by means of equation (5.1.1). The equation becomes:
La,c
I (Eq. 5.1.2)
Where: a,c
Eq. (5.1.2) makes use of the experimental exponents deduced by the flow sweep at the end of the tests.
Moreover, the stability of the debris bed was assumed. In order to compare the results against the first
acceptance criteria [ ]a,, the results obtained by the AP 1000 FA tests
are adjusted by eq. (5.1.2) to determine the DP at the acceptance criterion flow rate.
The peak dP measured during the test did not occur in all the tests when the debris bed was at the
maximum resistance. This relationship is discussed in Section 5.2 and the basis for this correlation is
provided in Section 8.39. This relationship is applied to both sequential debris addition and concurrent
debris additions, since this pressure drop represents the largest core head-loss modeled.
Table 5-1 below shows the values of exponent 'b' which applies to both sequential debris addition and
concurrent debris additions. CIBAP35, CIBAP38 and CIBAP39 are exempt since they are hot-leg tests.
Table 5-1 Values of the Exponent 'b' to be used in Equation (5.1.1)...a.C
Revision 5 5-3
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
Table 5-1 Values of the Exponent 'b' to be used in Equation (5.1.1)(cont.)________
For example, test CIBAP23 used sequential debris addition and was performed between
]a,c
Therefore,]a,c
5.1.2 Concurrent Debris Additions Acceptance Criteria (Second Acceptance Criteria)
a,c
I
As previously described, a second acceptance criterion was established for tests where concurrentadditions of debris were performed. The second criterion was based on sensitivity Case 3 in the LTCCanalysis (Reference 3). In this case the max dP allowed in the core at the beginning of the recirculationphase was 3.5 psi with a flow rate of [ ]pc The concurrent debris addition FA tests were set upto model the plant timing of debris addition after the start of recirculation. In contrast, the sequentialdebris addition tests were set up to determine the maximum dP value that would be achieved under thetest condition; therefore this acceptance criteria was not applicable for sequential debris addition tests.The second criterion applied to time less than 9 hours (plant time). As summarized in Table 9-2, for allconcurrent addition tests the flow prior to 9 hours was higher than [ ]a"c In order to compare thetest results against the second criteria, the experimental results were adjusted to ' ]alC by means of
eq. (5. 1. 1), that became:
Iac
I (Eq. 5.1.3)
5-4 Revision 5
5-4 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
where:
The exponent used in the correlation was reduced by the factor [ ]aC The basis for this reduction
factor is given in Section 8.39.3. An example of the application of this process is provided below.
a,c
Test CIBAP22 had the highest resistance in the debris bed [
pa'c Using the data from CIBAP22, the dP at 5.3 gpm is
then:
La,c
In this case, []a,c
5.2 DP/FLOW DEPENDENCE RELATIONSHIP
This section presents the method used to relate the change in dP across the fuel bundle to the change in
flow for the AP1000 FA head-loss test program. All AP1000 cold-leg break fuel tests performed to date
were considered. The results obtained from these tests provided an experimental basis to investigate the
dependence of the loss of pressure through the FA from the flow rate once the debris bed was formed.Tests CIBAP08 through CIBAPI I were performed with oscillating flow rates in order to simulate the
LTCC behavior of the APIOOO (Reference 3). Tests CIBAP18 through CIBAP34, plus CIBAP36 and
CIBAP37 were performed with flow sweeps after all the termination criteria were met.
The data collected by the tests allowed demonstrating as the head-loss and the flow rate are related by the
following equation, which is based on the Darcy formula, except that the exponent is determined by test
results:
La,c
I (Eq. 5.2.1)
Revision 5 5-5
Revision 5 5-5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
where:
K IWhen the debris bed is formed and stable, the pressure drop behavior of the debris bed will vary
consistently with flow rate. Therefore, [ ]a,c Once the value of
]a,, it is possible to evaluate the value of the loss of pressure at any
flow rate.
[a,c
I (Eq 5.2.2)
And then
[a.c
(Eq5.2.3)
where: a,c
Eq. 5.1.1 above has been used to verify that the AP1000 FA head-loss tests meet the acceptance criteria
established above. The applicability of the former correlation is justified in Section 8.39.3 for the two
acceptance criterion.
5-6 Revision 5
5-6 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
The exponent b has been evaluated for each test by best fit of the experimental data and the results are
summarized in the following tables:
Table 5-2 Exponent 'b' Obtained by Best Fit of the Experimental Data from the Tests Performed withOscillating Flow Rates and Sequential Additions (P/F/C) a,c
- II I II--
t _____ _____
Table 5-3 Exponent 'b' Obtained by Best Fit of the Experimental Data from the Tests Performed withSequential Debris Additions (P/F/C) from Section 5.1.1
Table 5-4 Exponent 'b' Obtained by Best Fit of the Experimental Data from the Tests Performed with
Coincident Debris Additions from Section 5.1.2
Revision 5 5-7
Revision 5 5-7
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Table5-4 Exponent 'b' Obtained by Best Fit of the Experimental Data from the Tests Performed with
(cont.) Coincident Debris Additions from Section 5.1.2 a,c
Several tests in the AP 1000 FA test program were performed with a [no data is available to determine the [
]apC and therefore,]a,c These tests used an
I ]a,c
Figure 5-1 shows the exponents for a fully formed debris bed estimated in the tests where the flow sweeps
where performed. The values are divided into three series representing the exponents obtained for
a~c
Several test parameters were different among those tests (e.g,
]a,, etc.) The exponent values were in the range
]ac The range of variability was [ ]a,, for the
three series, and in spite of the sample, the values seem to be consistent with [ ]a,c
(Figure 5-2). The exponent relevant to the fully formed bed was]'. The
exponent was [ ]ac The coefficient R (as well as its
variability) is related to [ ]a'c and how the []a,, (Figure 5-3). The distribution of the resistance coefficient for the same sample was[
],c (see Figure 5-4).
The []a, was acceptable for the tests performed with constant flow rate for which no data
is available to determine [ ]a Therefore, []a,c
5-8 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
-- , a,c
Figure 5-1 Values of the Exponent 'b' for the Fully Formed Debris Bed, Estimated in Test
CIBAP 08 through CIBAP 11 and CIBAP 18 through CIBAP 34 by a Best Fit of the
Experimental Data
-a,c
Figure 5-2 Distribution of the Exponent for the Fully Formed Debris Bed Estimated in Test
CIBAP 08 through CIBAP 11 and CIBAP 18 through CIBAP 34
Revision 5 5-9
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Figure 5-3 Coefficient "R" Values for the Fully Formed Debris Bed Estimated in Test CIBAP 08
through CIBAP 11 and CIBAP 18 through CIBAP 34 by a Best Fit of the
Experimental Dataa,c
Figure 5-4 Distribution of the Resistance Coefficient for the Fully Formed Debris Bed Estimatedin Test CIBAP 08 through CIBAP 11 and CIBAP 18 through CIBAP 34
5-10 Revision 5
5-10 Revisqion 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
6 DEBRIS PREPARATION
Debris preparation is an important factor in the justification of the applicability of these FA tests to the
AP 1000. The following subsections describe the preparation of the debris used in the AP 1000 FA head-
loss experiments. In-depth information on the debris used in the AP1000 FA head-loss experiments is
available in Appendix D.
6.1 PARTICULATE
Silicon carbide (SiC) with a 9.5-micron median particle size was used to simulate the particulate
component of the containment debris. The NRC Safety Evaluation for NEI 04-07 identified several
features for the particulate component of containment debris: the recommended specific gravity is
1.5 and ".... the major contributors to the head-loss are the increasing smaller particles (less than
75 jim).. ." (Reference 4). Silicon carbide has a specific gravity of about 3.2; although these particles
have a relatively high specific gravity, the test loop design prevents them from settling out. Because these
silicon carbide particles are about 9.5-microns in size, they act as a fine particulate debris that collects
within a fiber bed and results in a maximum head-loss across the recirculation screen. All particulate
material is well mixed into an aliquot of loop water until completely suspended before being introduced in
the test. Based on the above, the particulate used in the experiments is applicable to AP1000.
6.2 FIBERS
NUREG/CR-6877, Reference 12, indicates that fiberglass can be used as surrogate for latent fibers. It
goes on to say that for latent debris, "the fibrous surrogate fraction should be prepared such that the
length-to-diameter ratio is large and that it is conservative to assume that the latent fiber component has
similar hydraulic properties to those of fiberglass."
As presented in Appendix D,
]a~C Based on the above, the fibers used in the experiments are applicable to
AP1000.
Fiber types that were used in the AP1000 FA head-loss test program include:
Fiber A: [
]ac
1. NUKON® is a registered trademark of Performance Contracting, Incorporated.
Revision 5 6-1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Fiber B:
Fiber C:
Ii
ac
ac
Fiber D: I]a,c
Fiber E:
Fiber F:
]a,
]a,c
6.3 CHEMICAL PRECIPITATES
For the AP 1000 FA test program, all chemical surrogate was made outside of the loop according to theapproved procedure at the maximum allowable concentration of eleven grams per liter. Each batch was
tested for settling properties according to the approved procedure in WCAP-16530-NP-A (Reference 11)prior to introduction into the test loop. The batches of chemical debris were added to the test loop at
various rates, depending on the requirements of the particular test.
By following the approved method (Reference 6) of producing chemical surrogate and by following the
guidance of Reference 10, the chemical surrogate used in the AP1000 FA head-loss tests is applicable to
the AP1000 plant.
6.4 DEBRIS LOADS
Table 6-1 provides an overview of the AP 1000 post-LOCA design basis debris loads and the debris loadsassumed in the AP1000 FA head-loss test program (Reference 5) and ZOI coatings debris per TR26.
6-2 Revision 5
6-2 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Table 6-1 Original vs. Current AP1000 Post-LOCA Debris Load Design Basis a,c
Revision 5 6-3
Revision 5 6-3
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
7 TEST MATRIX AND INITIAL CONDITIONS
The test matrix was designed to improve the knowledge base of the behavior of the AP1000 design when
debris is transported to the core. Sensitivity tests were performed to better understand the influence of
several parameters such as the [
]a.C Tests were performed at constant, oscillating, and variable flow rates. For instance,
tests CIBAPO1, and CIBAP03 through CIBAP07, CIBAP 13 through CIBAP 16 and CIBAP39 were
performed at a constant flow rate. CIBAP02 and CIBAP08 through CIBAP12 were performed with
oscillating flow rates. Tests CIBAP17 through CIBAP34, CIBAP36 and CIBAP 37 were performed with
variable (decreasing) flow rates. Tests CIBAP35 and CIBAP38 were performed with a variable flow rate
then switched to a constant flow rate.
Tests CIBAPOI through CIBAP21, and test CIBAP23 were performed using sequential additions of
particles, then fibers, then chemical surrogate. Tests CIBAP22, and tests CIBAP24.through CIBAP39were performed with concurrent additions of particles, fibers, and chemical surrogate.
The initial conditions and test parameters of the AP 1000 FA head-loss experiments CIBAPO1 through
CIBAP39 are thoroughly covered in the test procedures presented in Appendix C of this document and aresummarized in, Table 7-1 through Table 7-4 below.
For constant flow rate tests, the flow rate used was
]a,c
For test CIBAPOI through CIBAP 15, the flow rate was based on the DCD base case; in this case the plant
flow rate was
]a,c
was a conservative round-up of this value.
For test CIBAP 16, the flow rate was based on the core flow rate of an LTCC sensitivity analysis, Case 3
of Reference 3, having a total []a,c This case assumes debris dP on the core and screens which reduces the flow rates. The flow
rate for test CIBAP16 was [ ]aC This minimum flow rate was also
applied to tests CIBAP 17 through CIBAP28. In these cases the flow started at higher rates and was
reduced as the dP increased.
Sensitivity Case 10 of Reference 3 reports a total injection flow of about 65 lb/s. This Case is the one on
which the acceptance criterion was based for a cold-leg break condition, as reported in Section 5.0. This
flow rate, scaled to the test, isa,c
According to the AP 1000 Long-term Cooling analysis, Reference 3, in the case of a DVI break located at
the reactor vessel, the maximum flow rate [ ]a" Note that
Revision 5 7-1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
this analysis assumed no dP, so this flow represents a high initial flow. Scaling this flow rate to]ac
Additionally, the analysis on the double-ended cold-leg guillotine break indicates a maximum core inlet
flow rate of about [ ]a,, In terms of gallons per minute, the flow is [ ]a,C Scaling this
flow rate to one FA results in [ ]a'c
The maximum flow rate for the cold-leg break tests was selected at [ ]a,, It should be noted that
for the previously discussed cases, the maximum flow rate refers to a clean condition in the FA (no
debris). This value was used as starting flow rate during some of the variable flow rate tests. In these
tests the flow was reduced as the dP caused by the buildup of debris increased, which simulates the
behavior of the plant.
Note that Reference 3 has been updated to include additional sensitivity analysis cases with even higher
core flow resistances for a hot-leg break condition. Sensitivity Case 11 reports a total injection flow of
214 Ibm/s, This is the case on which the acceptance criterion is based on for a hot-leg break condition, as
reported in Section 5.0). This flow rate, scaled to the test, is]a,c
The maximum flow rate that the loop can handle for the hot-leg break tests was selected at [ ]a c
According to the AP 1000 LTCC analysis, Reference 3, in the case of a double-ended cold-leg (DECL)
LOCA located at the reactor vessel, the maximum flow rate through 36 FA (all the outer edge FA) in the
core is about 214 lb/s, (1598 gpm). Note that this analysis assumed no dP, so this flow represents a
maximum initial flow during a hot-leg case flowing through the downcomer. Scaling this flow rate to
]a•c This flow rate refers to a clean condition in the FA. This
value was used as starting downward flow rate for hot-leg break tests CIBAP35 and CIBAP38.
]a,c
The initial loop temperature is set to [ ]aC for all tests except]a~c
7-2 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Table 7-1 Initial Conditions of AP1000 Fuel Assembly Head-Loss Tests CIBAPOI through CIBAPlO a,c
Revision 5 7-3
Revision 5 7-3
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Table 7-2 Initial Conditions of AP1000 Fuel Assembly Head-Loss Tests CIBAP11 through CIBAP20 a,c
L
7-4 Revision 5
7-4 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Table 7-3 Initial Conditions of AP1000 Fuel Assembly Head-Loss Tests CIBAP21 through CIBAP30 a,c
Revision 5 7-5
Revision 5 7-5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
Table 7-4 Initial conditions of AP1000 Fuel Assembly Head-Loss Tests CIBAP31 through CIBAP39 ac
7-6 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8 TEST RESULTS
8.1 SUMMARY OF AP1000 FUEL ASSEMBLY TESTING
All of the AP 1000 FA head-loss tests performed to date are presented in this section. Each of the testsperformed in this program considered a debris load of particulate, fiber, and chemicals in various
quantities that were intended to be representative of the AP 1000 debris load. Each test had specificacceptance and termination criteria based on dP and steady state conditions. Each test was allowed to run
to its termination so that the relationship between debris load and FA dP could be presented. As each testwas performed, the body of information related to the accumulation of debris on an AP 1000 FA wasincreased.
The following thirty-nine experiments were performed to investigate a spectrum of resident debris loadsand chemical effects. The data from all of the experiments, [
]a,c showed acceptable head-loss across the AP 1000 FA.
The results from this test program demonstrate the ability of the AP 1000 design to provide assurance ofLTCC debris loading conditions expected for the AP1000 following a postulated LOCA. Theseexperiments demonstrate that with the expected AP 1000 debris loading conditions, LTCC is assured.Head-losses due to the collection of debris within the fuel assemblies will not challenge either LTCC orthe maintaining of a coolable core geometry.
Data from the results of these experiments demonstrate that the design basis debris load that could exist inan AP 1000 containment resulted in an FA head-loss that was well within the calculated head-loss limitestablished for the AP 1000 in Reference 3 as defined in Section 5of this document.
Test runs CIBAPOI through CIBAP04 were initially presented in WCAP-17028-P, Revision 0 anddetailed in the Reference 7 test report. Test runs CIBAP05 through CIBAP16 were initially presented inWCAP-17028-P, Revision 1 and detailed in the Reference 8 and 14 test reports. Tests CIBAP07,CIBAP 12, and CIBAP 15, excluded from WCAP-17028-P, Revision 1, were presented and discussed inWCAP-17028-P, Revision 2. Test runs CIBAP17 through CIBAP30 were included along with theaforementioned tests in WCAP-17029-P, Revision 3 and detailed in the Reference 14 test report. Testruns CIBAP31 through CIBAP39 were included along with the aforementioned tests in this revision anddetailed in the Reference 15 test report.
The test reports, References 7, 8, 13, 14 and 15, provide a detailed record of test runs, debris loadings,flow rates, and procedures used to perform these tests. Table 8-1 provides a summary of the debris loadsand test results for the 'Evaluation of Debris Loading Head-loss Tests for AP 1000 Fuel AssembliesDuring Loss of Coolant Accidents.'
As described in Appendix E, the same facility and test apparatus configuration was used for each of theAP1000 FA head-loss tests (one noted exception is Test CIBAP17, see Section 8.16). Detailedphotographic coverage is provided for tests CIBAP 16 (sequential additions), CIBAP24 (concurrentadditions), CIBAP27 (concurrent additions), CIBAP30 (concurrent additions), CIBAP34 (concurrent
Revision 5 8-1
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
additions exploring flow patterns), CIBAP36 (concurrent additions simulating hot temperature and reactor
coolants), CIBAP38 (concurrent and sequential additions simulating downward flow switched over to
upward flow simulating boiling for a hot-leg break) and CIBAP39 (concurrent and sequential additions
simulating the upward flow and boiling for a hot-leg break) that follows the progression of debrisaccumulation on the FA.
Tests CIBAP07, CIBAP 12, CIBAP 17, and CIBAP 35 are discussed in Section 8.40.
8-2 Revision 5
8-2 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
Table 8-1 Summary of AP1000 Fuel Assemblies Head-Loss Tests a,c
Revision 5 8-3
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Table 8-1 Summary of AP1000 Fuel Assemblies Head-Loss Tests (cont.)a,c
8-4 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 8-5
Revision 5 8-5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIOOO
8.2 TEST #1 (CIBAP01)
This was the first of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the AP 1000. []a,C This experiment was performed according to the test plan STD-MCE-08-
79 presented in Appendix C of this document.
As described in test procedure STD-MCE-08-79,
]a,c
Figure 8-1 provides the head-loss and flow rate history for test CIBAPOI.
8-6 Revision 5
8-6 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Figure 8-1 Head-Loss and Flow Rate History for Test CIBAP01
Revision 5 8-7
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
8.3 TEST #2 (CIBAP02)
This was the second of the AP 1000 FA debris loading head-loss experiments performed in the STC test
]ac This experiment was performed according to the test plan STD-MCE-08-
80 presented in Appendix C of this document.
Test #2 was a sensitivity experiment with an increased debris loading as compared to Test #1.
]a,c
Following test procedure STD-MCE-08-80, [
]a,c
Similar to the results of Test #1, the amount of debris that was introduced into the test loop
]ac
8-8 Revision 5
8-8 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Figure 8-2 Head-Loss and Flow Rate History for Test CIBAP02
Revision 5 8-9
Revision 5 8-9
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.4 TEST #3 (CIBAP03)
This was the third of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the APIOOO. []a,c This experiment was performed according to the test plan
STD-MCE-08-81 presented in Appendix C of this document.
Test #3 was a sensitivity experiment with an increased debris loading as compared to Tests #1 and #2.The purpose of this experiment was to explore the limits of AP 1000 resident debris loadings withoutcompromising the reasonable assurance of LTCC. The debris mass loading was significantly increased
over the debris loads used in Tests #1 and #2. The amount of fiber was increased by approximately 14times the amount of fiber used in the bounding case test (CIBAP0 1).
The goal for this experiment was to reach approximately three feet of head-loss. This value was chosen
because it would define a debris load that was high for the AP1000 given the fact that the AP1000 designminimizes the potential to generate LOCA debris. The value of three feet of head-loss also allows asignificant margin to the acceptable head-loss value, ensuring a reasonable assurance of LTCC.
Following test procedure STD-MCE-08-81 (Appendix C), the experiment was performed with a constant
flow rate of [
]aC
NOTE: There was a data acquisition error at the beginning of this experiment which caused a loss ofrecorded data from the beginning of the test until shortly after the second addition of fibrous debris. Thefirst recorded data shown in Figure 8-3 was taken approximately one-half of a loop turnover after thesecond introduction of [ ]pc of resident fiber.
The amount of debris that was introduced into the test loop was sufficient to cause head-loss ofapproximately [
]a,c
8-10 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Figure 8-3 Head-Loss and Flow Rate History for Test CIBAP03
Revision 5 8-11
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.5 TEST #4 (CIBAP04)
This was the fourth of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the AP 1000. []aC This experiment was performed according to the test plan STD-MCE-08-
82 presented in Appendix C of this document.
Test #4 was a repeat of Test #2 [
]a,, Observations noted throughout the experiment and the recorded data showed that
the head-loss recorded was inconsequential when considering the impact of resident and chemical debrison the assurance of LTCC (Figure 8-4).
Following test procedure STD-MCE-08-82, the debris was introduced into the test loop in the samemanner as in Test #2. After loop stabilization was reached,
a,c
Similar to the results of Test #2, there was no reportable head-loss recorded for Test #4. The amount ofdebris that was introduced into the test loop was not sufficient to cause head-loss that would compromisethe reasonable assurance of LTCC.
8-12 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Figure 8-4 Head-Loss and Flow Rate History for Test CIBAP04
Revision 5 X-13
Revision 5 8-13
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
8.6 TEST #5 (CIBAP05)
This was the fifth of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the AP1000. []a,c This experiment was performed according to the test plan
STD-MCE-08-85 presented in Appendix C of this document.
In this case, the debris loadings were the values used in test CIBAP03 (test plan STD-MCE-08-81). Thegoal was to use the debris loading that was used in Test #3, but with
]a,c
Test CIBAP05 was different from the first four core inlet blockage tests conducted for the AP 1000primarily because of the difference in the [ ]ac The amounts of debris wereintended to be the same as those used in test CIBAP03. NUKON® fiber was still used in the case of testCIBAP05, but the distribution of the [
]apc The rest of the conditions, including flow rate, temperature, and debris additions, were the
same as those used in test CIBAP03.
The results of test CIBAP05 are summarized in Figure 8-5. After the particulate and fiber was added,
]a,c Since the fiber used in this test was non-typical of thelatent fiber (individual fibers) expected in the AP1000 containment, the rapid rise in head-loss associated
with the large addition of chemicals cannot be readily attributed to only the large quantitiy of chemicals
added. Since the test was very similar to CIBAP03, the results indicate that the interaction of the non-typical fiber and the chemicals together, and not the length of the fiber, played a larger role in thehead-loss attained in this test.
The average temperature in the test column for the test was
]ac The plot of flow
rate versus time in Figure 8-5 shows that there were a number of jumps in the flow rate. Many of these
corresponded to the additions made to the loop and were probably the result of rapid changes in
conductivity in the magnetic flow meter rather than real changes in the flow rate. The flow rate went
outside of the allowable range of [ ]ac at some points, but only for brief periods.
8-14 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
Figure 8-5 Head-Loss and Flow Rate History for Test CIBAP05
Revision 5 8-15
Revision 5 8-15
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.7 TEST #6 (CIBAP06)
This was the sixth of the AP 1000 FA debris loading head-loss experiments performed in the STC testfacility for the APIOOO. [
]a,c This experiment was performed according to the test plan
STD-MCE-09-18 presented in Appendix C of this document.
In this experiment, the debris loadings were based on a total AP1000 containment resident debris load of [
]a,c bypasses the screen
to reach the core.
The amounts of fiber, particulate, and chemical debris]aC" This change in fiber type
]a,c
Fiber B was used in this particular test to obtain a greater fraction of]ac
Figure 8-6 summarizes the data obtained during the test along with the timing of the debris additions.The maximum head-loss
]a'c There were
occasional spikes in the head-loss as it was dropping off. These were generally associated with furtheradditions of chemical debris.
The average flow rate during the test was]pc There were a few large spikes in the flow rate during the test. The spikes in
most cases corresponded to the addition of the chemical debris. At the time of the first addition, it
appeared that the addition of the chemical produced a rapid increase in the conductivity of the solutionproducing a few seconds of erroneously high flow values at the magnetic flow meter.
The temperature in the test column was an average of []a'c The pressure drop decreased continuously after addition of all
chemical debris, so the test was terminated after 7.7 hours,even though the equilibrium termination
criterion was not met.
8-16 Revision 5
8-16 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Figure 8-6 Head-Loss and Flow Rate History for Test CIBAP06
Revision 5 8-17
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
8.8 TEST #8 (CIBAP08)
This was the eighth of the AP 1000 FA debris loading head-loss experiments performed in the STC testfacility for the AP 1000. [
]a,c This experiment was performed according to the test plan
STD-MCE-09-28 presented in Appendix C of this document.
In this experiment, the debris loadings were based on a total AP1000 containment resident debris load of
ac
In addition, at any point in time, the flow also oscillates with a period of several minutes and with aminimum flow rate of about [ ]a"C This oscillation is seen in the LTCC analysis andsimulated in select AP 1000 fuel assembly head-loss tests.
Test CIBAP08 used the same total fibrous and particulate debris loading as was used in test CIBAP06.
The same fiber as used in test CIBAP06, [ ]ac CIBAP08 had
]aC The primary
differences between CIBAP08 and CIBAP06 were the use of]apc in CIBAP08.
The flow rate and pressure drop results, as well as the timing of the debris additions, are summarized inFigure 8-7. Neither the SiC particulate nor the fibrous debris additions caused an increase in thehead-loss across the FA. The first chemical debris addition
]ac
The average temperature in the test column and mixing tank during test CIBAP08 was []"' For both of these flow rates, the value stayed within the
allowed flow range throughout the test, though it was obvious that there was some variation at differentpoints in the test as the flow rates were manually adjusted. The upper flow rate was closer to [ ]during the test, which was still within the allowed range.
For termination, the test was allowed to run for 75 minutes after the final addition of chemical debris.The termination criteria were checked, but since the oscillating flow had an effect on the measuredhead-loss, the termination criterion was not precisely met. The test was ended because the oscillatingflow precluded the possibility of reaching an exact equilibrium condition.
Test CIBAP08 was allowed to run overnight to determine what would happen with pressure, settling, and
debris movement after running for an extended period. Neither the dP nor the location of debris capture
changed during this extended operation. However,
pac
8-18 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 8-7 Head-Loss and Flow Rate History for Test CIBAP08
Revision 5 8-19
Revision 5 8-19
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
8.9 TEST #9 (CIBAP09)
This was the ninth of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the AP 1000. []a,c This experiment was performed according to the test plan
STD-MCE-09-34 presented in Appendix C of this document.
In this experiment, the parameters were the same as those used for CIBAP08. The debris loadings were
based on a total AP 1000 containment resident debris load
]a,c
In addition, at any point in time, the flow also oscillates with a period of several minutes and with a
minimum flow rate of about [ ]a"C This oscillation is seen in the LTCC analysis
(Reference 3) and simulated in select AP 1000 fuel assemble head-loss tests, therefore it was assumed
60% of the fiber would reach the core.
The only difference between this test and test CIBAP08 was that the fiber used for this experiment was
obtained from PCI in the [
ac
Test CIBAP09 was conducted to determine the pressure drop characteristics of a debris mix with a
pc were not significantly different from one another. Therefore, the results of
test CIBAP09 and test CIBAP08 should be compared to one another as if they were run under the same
conditions.
The results of CIBAP09 were generally similar to those obtained in test CIBAP08. The pressure and flow
rate data and the timing of the debris additions for CIBAP09 are given in Figure 8-8. Addition of the SiC
particulate had no effect on the head-loss and addition of the fiber
pac
The temperature in the test column and the mixing tank during the test]p'c For both the upper and the lower flow rates,
the measured values were within the allowed ranges.
The termination criterion was checked at the end of the test despite this being an oscillating flow test.
The slope of the dP versus time curve was below the termination criterion.
8-20 Revision 5
8-20 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-8 Head-Loss and Flow Rate History for Test CIBAP09
Revision 5 8-21
Revision 5 8-21
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
8.10 TEST #10 (CIBAPO)
This was the tenth of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the AP 1000. []a,c This experiment was performed according to the test plan
STD-MCE-09-35 presented in Appendix C of this document.
In this experiment, the debris loadings were based on a total AP 1000 containment resident debris load of
I
]ac These are the same values that were used in tests CIBAP08 and CIBAP09. This test
also employed a [ ]a,, in the AP1000.
In addition, at any point in time, the flow also oscillates with a period of several minutes and with a
minimum flow rate of about [ ]a"C This oscillation is seen in the LTCC analysis
(Reference 3) and simulated in select AP 1000 fuel assemble head-loss tests therefore it was assumed
60% of the fiber would reach the core.
The fiber used for this experiment was
]ac
Test CIBAP10 had similar conditions to tests CIBAP08 and CIBAP09. The only difference between test
CIBAP10 and tests CIBAP08 and CIBAP09 was
ac
The pressure and flow rate results as well as the timing of the debris additions for CIBAP 10 are
summarized in Figure 8-9 Some difficulties with the data acquisition system were encountered during this
particular test. The flow control program caused the flow rate to hold at [ ]ac for approximately 20
minutes just after four hours had passed in the test. At just over six hours into the test, the data collectionprogram froze and stopped collecting data. It took 45 minutes to correct this problem, so the pressure and
flow data between these points were lost. The flow control program continued to operate during thistime, and therefore the test itself was not disturbed. These problems, corrected after the test by rebooting
the computer, were not experienced in subsequent tests.
Despite these difficulties, the test was successful in showing that the debris loading used was acceptable.
The addition of SiC particulate had no effect on the head-loss and the addition of the fiber]aC The first chemical debris addition
]ac
The average temperature in the test colunm]a,' The flow rate was within
8-22 Revision 5
8-22 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
the acceptable range for the high and low flow rates throughout the test except at three points which are
seen on the plot in Figure 8-9. The first was !a number of low spikes in the flow rate during the first hour
of the test. These low spikes had no effect on the test because they occurred before any debris was added.
The second was when the flow control program caused the flow rate to hold at the high value for much
longer than it was programmed to. During this time period, the flow rate did not go outside of the
allowable range for the higher flow rate. The final excursion was at about 6 hours into the test when the
upper flow rate spiked to a value of approximately [ ]a"c This spike at six hours was brief and did
not cause a change in pressure drop or a visible rearrangement of the debris bed.
a,c
Figure 8-9 Head-Loss and Flow Rate History for Test CIBAP10
Revision 5 8-23
Revision 5 8-23
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.11 TEST #11 (CIBAPll)
This was the eleventh of the AP 1000 FA debris loading head-loss experiments performed in the STC testfacility for the APIOOO. [
]ac This experiment was performed according to the test plan
STD-MCE-09-39 presented in Appendix C of this document.
In this experiment, the debris loadings were based on a total AP1000 containment resident debris load of
I ]"'c It was assumed that all of
this resident debris
]apc Test CIBAP 11 was conducted with the same debris amounts as Tests 8, 9, and 10, but
p~c
In addition, at any point in time, the flow also oscillates with a period of several minutes and with a
minimum flow rate of about [ ]arc This oscillation is seen in the LTCC analysis(Reference 3) and simulated in select AP1000 fuel assemble head-loss tests, therefore it was assumed60% of the fiber would reach the core.
The fiber used for this experiment [
]a" Table 8-2 specifies the quantities for each of the types of fibrous debris
used to create this particular fibrous representation of the latent debris (Reference 8).
Table 8-2 Fibrous Debris Mix Used in Test CIBAPll a,c
The head-loss and flow rate results as well as the timing of the additions are summarized in Figure 8-10.Neither the addition of SiC particulate nor the addition of the fiber caused an increase in the head-loss.
]a,c
In the earlier tests the debris bed [
8-24 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
]a,c
The average temperature in the test column during the test [
]a C Both of these spikes in the flow rate coincided with debris additions and
were probably side effects of the variations in the local conductivity of the fluid passing through the
magnetic flow meter.
Figure 8-10 Head-Loss and Flow Rate History for Test CIBAPll
a,c
Revision 5 8-25
Revision 5 8-25
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.12 TEST #13 (CIBAP13)
This was the thirteenth of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the AP1000. []a,c This experiment was performed according to the test plan
STD-MCE-09-42 presented in Appendix C of this document.
In this case, the fibrous debris loadings were set at [ ]a,, was used in test
CIBAP13 (see Section 6.2, Fiber). The fiber load was based on]ac It was assumed that all of this resident debris
a ]ac The chemical
surrogate was generated outside of the loop using the standard WCAP-16530-NP-A (Reference 11)
procedure.
Test CIBAP13 was similar to test CIBAP08 in terms of the type of debris used.
ca,
I]a, into the mixing tank at a specified rate. Per test procedure
STD-MCE-09-42 presented in Appendix C, the chemicals were [
]a'c Figure 8-12 summarizes the A1OOH concentration during the test
and compares it to twice the calculated amount of chemical concentration in the AP 1000 during a LOCA.
The use of the factor of two conservatism is in accordance with NRC recommendations. These plots
demonstrate that the amount of A1OOH added to test CIBAP 13 []ac The production rate was chosen based on guidance provided in
References 10 and 11.
The pressure and flow rate results, as well as the timing of the additions for test CIBAP 13, are
summarized in Figure 8-11. After the addition of the SiC particulate,The addition of the fiber caused only a [
Ia,c
Ia,c
The average temperature in the mixing tank during test CIBAP 13 was [
]a The temperature in the test column was slightly outside of
the specified temperature range in the test plan, but this deviation should have had no effect on the test
results.
8-26 Revision 5
8-26 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The average flow rate during the test was [ ]"C The flow had some small spikes during the test, butnone of these went outside of the allowable range in the test plan.
Figure 8-11 Head-Loss and Flow Rate History for Test CIBAP13
Revision S 8-27
Revkisin 5 8-27
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-12 Concentration of Chemical Debris with Time
8-28 Revision 5
8-28 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
8.13 TEST #14 (CIBAP14)
This was the fourteenth of the AP 1000 FA debris loading head-loss experiments performed in the STC
test facility for the AP1000. []aC This experiment was performed according to the test
plan STD-MCE-09-45 presented in Appendix C of this document.
In this experiment, the particulate, fiber, and chemical debris loadings were set to the same values used in
Test CIBAP 13. However, the type of fiber used was Fiber
]ac The production rate was chosen based on
guidance provided in References 10 and 11.
The pressure and flow rate results, as well as the timing of the debris additions for test CIBAP 14, are
summarized in Figure 8-13. The gradual additions of chemical debris are noted on the plot. The addition
of the SiC particulate]a C The first continuous addition of AIOOH
chemical debris[ ]a c After this first
addition of A1OOH, the test plan
]p' The test was then allowed to stabilize for 8.5 hours until the equilibrium criterion was met. At
this point, additional chemical debris was added by pouring the liquid rather than pumping it into the
mixing tank. The head-loss reached []a,c
Approximately two hours after the second continuous addition of the chemical debris, the water in the
loop was cloudy white from the AIOOH in suspension. Five hours later the water had become noticeably
clearer. The chemical debris was gradually filtered out of the water causing the clarity and at the same
time increasing the head-loss.
The overall appearance of the debris bed was similar to that observed seven hours after the second
continuous AlOOH addition. One difference at the end of the test was the accumulation of what was most
likely a layer of A1OOH and SiC particulate on the bottom face of the debris bed. Another difference was
the amount of chemical debris and SiC particulate that had settled out on top of the FA and also on top of
some areas of the support grids. This settling was also seen in other tests and it is reasonable that some
settling of debris would take place in low-flow locations of an AP 1000 reactor or in containment after a
LOCA. However, the turbulence caused by boiling would likely minimize settling at the top of the
assembly. Boiling was evaluated in CIBAP38 and CIBAP39 and is discussed in Section 8.37, Section
8.38, and Section 9.17.
Revision 5 8-29
Revision 5 8-29
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
The average temperature in the test column during test CIBAP14 was []aC
There were small spikes in the flow rate throughout the test, but only one of these went outside of the
allowable range given in the test plan. At just over four hours into the test, I]pc This appeared to have no effect on
the results of the test.
Figure 8-13 Head-Loss and Flow Rate History for Test CIBAP14
a,c
8-30 Revision 5
8-30 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.14 TEST #15 (CIBAP15)
This was the fifteenth of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the AP1000.]a"C This experiment was performed
according to the test plan STD-MCE-09-61 presented in Appendix C of this document.
In this case, the fibrous debris loadings were set at [ ]a,, was used in test
CIBAP15 (see Section 6.2, Fiber). The debris load was based on [] It was assumed that all of this fibrous and particulate debris
]a,c
Test CIBAP 15 included more [
]a,c
I]a,, into the mixing tank at a specified rate. For conservatism, the
concentration of chemical debris in the test loop was targeted to be above twice the calculated
concentration in the AP1000 during a LOCA event. The use of the factor of two conservatism is in
accordance with NRC recommendations. The production rate was chosen based on guidance provided in
Reference 10 and Reference 11.
The pressure and flow rate results, as well as the timing of the debris additions for test CIBAP 15, are
summarized in Figure 8-14. After the addition of the SiC particulate, [
pac
The pressure drop increase occurred [ ]ac This is
demonstrated by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower" in Figure 8-14.
The pressure drop increase across
]a,c
No visible debris beds or blockages formed when the particulate debris was added.
]a,c
Revision 5 8-31
Revision 5 8-31
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
The average temperature for both the test column and the mixing tank during the test was []a,c which was well within the allowable flow rate. The flow rate did not
spike outside of the control band except for a brief excursion when the fiber added. Since this excursion
occurred before the bed formed, it had no effect on the test results. The maximum pH during the test
was [ ]a"C This was within the allowable range for the test (5 to 9), so any dissolution of the chemical
product surrogate was insignificant.
Figure 8-14 Head-Loss and Flow Rate History for Test CIBAP15
a,c
8-32 Revision 5
8-32 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
8.15 TEST #16 (CIBAP16)
This was the sixteenth of the AP 1000 FA debris loading head-loss experiments performed in the STC test
facility for the AP1000.]aC This experiment was performed
according to the test plan STD-MCE-09-71 presented in Appendix C of this document.
In this case, the fibrous debris loadings were set at [
]aC (Figure 8-16). It was assumed that all of this
fibrous and particulate debris was transported to the recirculation screen area and that
a,c
The rate of chemical surrogate addition was the same as used for test CIBAP 14. The reduced rate of
chemical additiona,c
],,c into the mixing tank at a specified rate. As in test CIBAP14,
]ac For conservatism, the concentration of chemical debris in the
test loop was targeted to be more than twice the calculated concentration in the AP 1000 during a LOCA
event. The use of the factor of two times the concentration is in accordance with NRC recommendations.
The production rate was chosen based on guidance provided in Reference 10 and Reference 11.
The pressure drop increase occurred a ]"' This is
demonstrated by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower" in Figure 8-15.
The pressure drop increase across [
]ac
The average temperature for both the test column and the mixing tank during the test was [ ]"C The
average flow rate during the test was [ ]ac The flow had some small spikes during the test and a
brief excursion when the fiber added. This excursion occurred before the bed formed, so it had no effect
on the test results. The maximum pH during the test was [ pac This was within the allowable range for
the test (5 to 9), so any dissolution of the chemical product surrogate was insignificant.
The pressure and flow rate results, as well as the timing of the additions for test CIBAP 16, are
summarized in Figure 8-15. Starting with a clean assembly (Figure 8-17), the addition of the SiC
particulate (Figure 8-18), [ ]aC The addition of the fiber caused only a [
]a,, (Figure 8-19). At this time, the additions of particulate and fiber result in
a uniform build-up of debris along the edge of the bottom nozzle and the bottom of the p-grid
(Figure 8-20) that increases with the addition of the chemicals. With the more gradual addition of
chemicals, the head-loss did not increase as suddenly, however, the first two additions of the chemical
Revision 5 8-33
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
surrogate did result in the head-loss increasing gradually to [ ]ac Note that
between the first and second chemical additions (Figure 8-20 and Figure 8-21), the debris bed on both the
lower left and right shows significant break through and reduced accumulation along the bottom of the p-
grid. By the third chemical addition, the debris has taken on a smoother appearance and essentially no
debris remains at the bottom of the p-grid (Figure 8-22). After the third chemical addition, the dP
increase [ ]a,c The pressure drop vs. time curve was fairly level after the
fourth chemical addition. The seventh and last chemical addition shows a smooth and well defined debris
bed with visible layers of chemicals and very little debris on the bottom nozzle or p-grid (Figure 8-23).
The final addition resulted in no additional head-loss increases. Thereafter, the pressure drop began a
slow decline and then leveled at a final value of [ ]a,c
Figure 8-15 Head-Loss and Flow Rate History for Test CIBAP16
8-34 Revision 5
8-34 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 8-16 Debris Load For Test CIBAP16
a,c
Figure 8-17 Clean Assembly For Test CIBAP16
Revision 5 8-35
Revision 5 8-35
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Figure 8-18 Addition of Particulates for Test CIBAP16
a,c
Figure 8-19 Accumulation of Fiber at Bottom Nozzle and P-Grid for Test CIBAP16
8-36 Revision 5
8-36 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-20 Debris Bed After Chemical Introduction For Test CIBAP16
a,c
Figure 8-21 Debris Bed After the Second Chemical Introduction For Test CIBAP16
Revision 5 8-37
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-22 Debris Bed After The Third Chemical Introduction For Test CIBAPI6
a,c
Figure 8-23 Debris Bed After Final Chemical Introduction For Test CIBAP16
8-38 Revision 5
8-38 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.16 TEST #17 (CIBAP17)
This was the seventeenth of the FA debris loading head-loss experiments performed in the STC test
facility for the AP1000.]a C This experiment was performed
according to test plan STD-MCE-09- 101 presented in Appendix C of this document. All debris was
added sequentially with particulate followed by fiber followed by chemical surrogate.
In this experiment, the debris loadings were based on a total AP1000 post-LOCA containment debris load
]a'c The results of test CIBAP17 are plotted in Figure 8-24.
On the day test CIBAP17 was to be performed, there were delays in starting the test. After the test was
started and the particulate debris was introduced into the test loop, it was decided that it was too late in
the day to complete the test. The flow through the loop was inadvertently stopped overnight and this was
a deviation from the test procedure. The test was completed the next day. Also note that the test loop
piping associated with this test was configured differently (see loop diagram Figure 8-25) than that used
in previous AP1000 FA head-loss tests. Because of these issues with how this test was run and the
different loop configuration used, the test was considered invalid. A root cause analysis was initiated on
this test.
The particulate debris that had been in the loop for approximately 24 hours had no effect on the head-loss
across the assembly. [a,c
At the onset of chemical addition,
ac
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location. This can be
deduced by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower" in Figure 8-24. The
pressure drop increase across the bottom nozzle (dP Lower) was the same as total pressure drop increase
Revision 5 8-39
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
across the entire assembly. The pressure drop between the top of the p-grid and the top of the assembly(dP Upper) was recorded at a maximum of [ ]a,c at the time of test termination.
The average temperature for both the test column and the mixing tank during the test was [ ]a c Theflow rate was [
]ac The pH was measured throughout the test reaching a maximum pH of [ ]"'C This was
within the allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate wasinsignificant.
Figure 8-24 Head-Loss and Flow Rate History for Test CIBAP17
8-40 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 8-25 Schematic of The Test Loop Configuration For CIBAP17
Revision 5 8-41
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
8.17 TEST #18 (CIBAP18)
This was the eighteenth of the FA debris loading head-loss experiments performed in the STC test facility
fortheAP1000. []ac This experiment was performed according to test plan
STD-MCE-09-102 presented in Appendix C of this document. All debris was added sequentially with
particulate followed by fiber followed by chemical surrogate.
In this experiment, the debris loadings were based on a total AP 1000 post-LOCA containment debris load
]aC The results of test CIBAP 18 are plotted in Figure 8-26.
The addition of particulate and fiber had little effect on the head-loss across the full assembly. The
particulate caused zero pressure drop increase and the combination of fiber and particulate resulted in an
increase of [a'c
At the onset of chemical addition,
ac
In this test,
]a,c per the test procedure and held until the
acceptance criterion was met again.
At this point in the test a series of flow sweeps were performed at higher and lower flows than the flow
recorded at test termination. The flow sweeps were performed to determine the pressure drop dependence
on flow rate.
In test CIBAPI18, the pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid
location. This is demonstrated by comparing the trace labeled "dP Upper" to the trace labeled "dP
Lower" in Figure 8-26. The pressure drop increase across the bottom nozzle (dP Lower) was slightly less
than the total pressure drop increase across the entire assembly indicating that some debris was
accumulating in the upper portion of the bundle. The pressure drop between the top of the p-grid and the
top of the assembly (dP Upper) was recorded at approximately [ ]a, for the portion of the test
prior to the flow sweeps.
No visible debris beds or blockages formed when the particulate debris was added. After the fiber
addition, a fiber bed developed at the bottom nozzle/p-grid. The dP at this time suggested that the debris
bed had significant porosity. When the chemical surrogate was first added, there was not a great deal of
8-42 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
visible change in the bed and bits of fiber were observed above the p-grid. By the time the last chemical
addition was in, only a small amount of fiber was observed to remain above the p-grid.
The average temperature for both the test column and the mixing tank during the test was [ ]a, The
flow rate was []a,c The pH was measured throughout the test reaching a maximum pH of [ ]aC This was
within the allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate was
insignificant.
Figure 8-26 Head-Loss and Flow Rate History for Test CIBAP18
Revision 5 8-43
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
8.18 TEST #19 (CIBAP19)
This was the nineteenth of the FA debris loading head-loss experiments performed in the STC test facility
for the APIOOO. []a"c This experiment was performed according to test plan
STD-MCE-09-103 presented in Appendix C of this document. []a,c
In this experiment, the debris loadings were based on a total AP 1000 post-LOCA containment debris load[
]a"c The results of test CIBAP19 are plotted in
Figure 8-27.
The additions of particulate had very little impact on the recorded dP. After the introduction of the fiber,
the fiber and particulate together resulted in a dP [ ]"C Following the recommended
loop turnovers, chemical debris was introduced into the loop.
In conjunction with the introduction of chemicals, a flow reduction scheme was initiated to reduce the
flow rate commensurate with the increase in dP across the bundle. The addition of chemical debris had a
significant effect. The first two chemical additions increased the pressure drop from a value of [
]C At this point, the data was checked to see if it met
the termination criteria. After successfully meeting the termination criteria, the flow rate was reduced toI ]ac and the dP was allowed to equilibrate. After meeting the termination criteria flow sweeps
were started to assess the impact of pressure drop dependence on flow rate.
In test CIBAP 19, the pressure drop increase occurred almost exclusively at the
]a,,. This is demonstrated by comparing the trace labeled "dP Upper" to the trace labeled "dPLower" in Figure 8-27. The pressure drop increase across the bottom nozzle (dP Lower) was essentially
the same as total pressure drop increase across the entire assembly. The pressure drop between the top of
the p-grid and the top of the assembly (dP Upper) changed insignificantly during the test.
No visible debris beds or blockages formed when the particulate debris was added. After the first fiber
addition, a fiber bed developed at the bottom nozzle/p-grid. The dP at this time suggested that the debris
bed had significant porosity. When the chemical surrogate was first added, there was not a great deal of
visible change in the bed. As more chemical was added, a dense white layer formed within the bed at the
bottom of the bottom nozzle. Only small amounts of fiber were observed above the p-grid. By the end of
the test, the debris bed loaded with chemical precipitates is easily seen.
8-44 Revision 5
8-44 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
The average temperature for both the test column and the mixing tank during the test was [ ]ac Themaximum pH during the test was [ ]a,C This was within the allowable range for the test (5 to 9), soany dissolution of the chemical product surrogate was insignificant.
Figure 8-27 Head-Loss and Flow Rate History for Test CIBAP19
Revision 5 8-45
Revision 5 8-45
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
8.19 TEST #20 (CIBAP20)
This was the twentieth of the FA debris loading head-loss experiments performed in the STC test facility
for the AP1000. With the debris load and chemical precipitate tested (Table 8-1), the peak head-lossrecorded for this test was [ ]a"C This experiment was performed according to test
plan STD-MCE-09-107 presented in Appendix C of this document. All debris was added sequentially
with particulate followed by fiber followed by chemical surrogate.
In this experiment, the debris loadings were based on a total AP1000 post-LOCA containment debris load
]a.c The results of test CIBAP20 are plotted in
Figure 8-28.
The additions of particulate and fiber had little effect on the head-loss across the full assembly. Theparticulate caused zero pressure drop increase and the addition of fiber caused an increase
]a,c
In conjunction with the introduction of chemicals, [
]a"C Flow sweeps were initiated after all termination criteria were met.
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location. This is
demonstrated by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower" in Figure 8-28.
The pressure drop increase across the bottom nozzle (dP Lower) was the same as total pressure drop
increase across the entire assembly. The pressure drop between the top of the p-grid and the top of the
assembly (dP Upper), did not change during the test.
No visible debris beds or blockages formed when the particulate debris was added. After the first fiber
addition, a fiber bed developed at the bottom nozzle/p-grid. When the chemical surrogate was first added,
there was not a great deal of visible change in the bed. As more chemical was added, a white layer
formed within the bed at the bottom of the bottom nozzle and the fiber seemed to migrate up the p-grid
away from the nozzle. After meeting all termination criteria at []a, significant amounts of fiber were observed above the
p-grid and the debris bed under the bottom nozzle appeared to be settling on the core support plate.
The average temperature for both the test column and the mixing tank during the test was [ ]ac The
flow rate was initially at [ ]a,, over the course of the
experiment. The pH was measured throughout the test reaching a maximum pH of [ ]a," This waswithin the allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate was
insignificant.
8-46 Revision 5
8-46 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Figure 8-28 Head-Loss and Flow Rate History for Test CIBAP20
Revision 5 8-47
Revision 5 8-47
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.20 TEST #21 (CIBAP21)
This was the twenty-first of the FA debris loading head-loss experiments performed in the STC test
facility for the AP1000. []a,c This experiment was performed according to test
plan STD-MCE-09-108 presented in Appendix C of this document. All debris was added sequentially
with particulate followed by fiber followed by chemical surrogate.
In this experiment, the debris loadings were based on a total AP1000 post-LOCA containment debris load
]ac The results of test CIBAP21 are plotted in
Figure 8-29.
The additions of particulate and fiber had little effect on the head-loss across the full assembly. Theparticulate caused zero pressure drop increase and the fiber with particulate resulted in an increase
pac
At the onset of chemical addition, a flow reduction scheme was used to reduce the flow ratecommensurate with the increase in dP associated with the chemicals. The test flow and dP initiallytracked well with the performed flow reduction.
]a,c
Per the test procedure, the flow rate [ ]a"C held until the termination criterionwas met. At this point in the test flow sweeps were performed to determine the pressure drop dependence
on flow rate.
As in the other tests, the pressure drop increase occurred almost exclusively at
]a"c This can be seen by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower"
in Figure 8-29. The pressure drop increase across the bottom nozzle (dP Lower) was the same as totalpressure drop increase across the entire assembly. The pressure drop between the top of the p-grid and thetop of the assembly (dP Upper) measured ]a ],c during the pre-flow sweep portion of thetest.
When the particulate material was added, no blockages were observed at any location and the particulatewas well distributed about the test article. After the fiber addition, a fiber bed developed between thebottom nozzle and the p-grid. The fiber bed appeared to have significant porosity as the dP due to fiberand particulate was about [ ]ac When the chemicalproduct surrogate was added, the bed porosity appeared to go down as indicated by the rise in d. Afterthe second chemical addition, the fiber bed showed signs of instability such that the dP dropped,
8-48 Revision 5
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
recovered and dropped again prior to the third chemical addition. Further chemical additions resulted in
small increases with [ ]a,c Late in the test, the chemicals were readily seen in the
debris bed with only small amounts of fiber observed above the p-grid. Even though the bed looked very
thick, the makeup of the bed must have been such that fluid could pass through it with relative ease
because no further increase in dP was observed.
The average temperature for both the test column and the mixing tank during the test was [ ]a'c The
flow rate was initially at []apc The pH was measured throughout the test reaching a maximum pH of [ ]aC This was
within the allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate was
insignificant.
Figure 8-29 Head-Loss and Flow Rate History for Test CIBAP21
Revision 5 8-49
Revision -5 8-49
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
8.21 TEST #22 (CIBAP22)
This was the twenty-second FA debris loading head-loss experiments performed in the STC test facility
fortheAPIOOO. []a c This experiment was performed according to test plan
STD-MCE-09-109 presented in Appendix C of this document.]a,c
In this experiment, the debris loadings were based on a total AP 1000 post-LOCA containment debris load
]a C The results of test CIBAP22 are plotted inFigure 8-30.
The first concurrent addition of particulate, fiber, and chemical precipitates had little effect on thehead-loss across the full assembly resulting in [
]a,c
As in the previous tests, a flow reduction scheme was used to reduce the flow rate commensurate with theincrease in dP across the FA bundle. In previous tests, the reduction scheme was only applied at theintroduction of the chemical precipitates. For this test, the reduction scheme was applied from thebeginning of the test as the dP attributed to debris accumulation increased.
]a,c
An interesting observation from this test is that the fiber appeared to accumulate around the bottom of the
p-grid prior to accumulating around the bottom nozzle. This accumulation begins to appear just prior to
the second addition and continues through the fourth addition when a debris bed begins to form around
the edges of the bottom nozzle. Also seen in this concurrent debris addition test is the accumulation of
fibers in the middle of the first grid above the p-grid and along the bottom of the second grid above the
p-grid.
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests. This can be seen by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower"
in Figure 8-30. The pressure drop increase across the bottom nozzle (dP Lower) was approximately the
same as total pressure drop increase across the entire assembly.
]ac
8-50 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
I]ac held until termination criteria were met, and flow sweeps were to be initiated. As seen in
Figure 8-30 the flow sweep program did not run.
The average temperature for both the test column and the mixing tank during the test was [ ]ac The
flow rate was initially at []a,c The pH was measured throughout the test reaching a maximum pH of [ ]a,c This was
within the allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate was
insignificant.
Figure 8-30 Head-Loss and Flow Rate History for Test CIBAP22
Revision 5 8-51
Revision 5 8-51
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.22 TEST #23 (CIBAP23)
This was the twenty- third FA debris loading head-loss experiments performed in the STC test facility forthe AP1000. [
]a.C This experiment was performed according to test
plan STD-MCE-09-113 presented in Appendix C of this document. All debris was added sequentially.
In this experiment, the debris loadings were based on a total AP 1000 post-LOCA containment debris load
]a~C The results of test CIBAP23 are plotted in
Figure 8-3 1.
This is a repeat of test CIBAP17. For this test, there were no delays in starting the test as discussed inSection 8.16. This test uses the same loop plumbing as described in Section 4.1.
The addition of the particulate had no effect on the loop d. The particulate caused zero pressure dropincrease and the addition of fiber resulted in an
]ac
The third chemical addition resulted in the
],,c At this point, the steady state termination
criterion was met and flow sweeps were initiated.
As in the other AP 1000 FA debris tests, the pressure drop increase occurred almost exclusively at thebottom nozzle/p-grid location. This is demonstrated by comparing the trace labeled "dP Upper" to thetrace labeled "dP Lower" in Figure 8-31. The pressure drop increase across the bottom nozzle (dP Lower)
was the same as total pressure drop increase across the entire assembly. The pressure drop between thetop of the p-grid and the top of the assembly (dP Upper), did not change during the test.
As in the previous sequential addition tests, a flow reduction scheme were used at the onset of chemicaladdition to reduce the flow rate commensurate with the increase in dP associated with the chemicaladditions. The test flow and dP initially tracked well with the performed flow reduction as seen inFigure 8-3 1. At approximately 4.19 hours into the test, the slope of the flow reduction was set to 0.0 at aflow rate of [ ]•'C During this steady state condition the fourth through seventh chemical additionswere prepared and introduced into the loop.
When the particulate material was added, no blockages were observed at any location and the particulatewas well distributed about the test article. After the fiber addition, a fiber bed developed at the bottomnozzle and between the bottom nozzle and the p-grid. Due to the small increase in dP, it is assumed thatthe fiber bed must have had significant porosity. After the chemical surrogate was added, the bed porosity
8-52 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
decreased as indicated by the rise in dP. At this point in the test, with all of the fiber, particulate, and
first chemical addition in the loop, the debris looked rough and uneven. After the second chemical
addition, the debris began to look smoother 'and the amount of debris located on the p-grid had been
greatly reduced. By the seventh and final chemical addition, the debris was very smooth with visible
layers of chemicals and only a small amount of fiber above the p-grid.
The average for both the test column and the mixing tank during the test was [ ]aC The flow rate was
initially at [ ]a c The pH was
measured throughout the test reaching a maximum pH of [ ]a,c This was within the allowable range
for the test (5 to 9), so any dissolution of the chemical product surrogate was insignificant.
Figure 8-31 Head-Loss 'and Flow Rate History for Test CIBAP23
Revision 5 8-53
Revision 5 8-53
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.23 TEST #24 (CIBAP24)
This was the twenty-fourth FA debris loading head-loss experiments performed in the STC test facility for
the AP1000. []pc This experiment was performed according to test plan
STD-MCE-09-115 presented in Appendix C.]a,c
In this experiment, the debris loadings were based on a total AP1000 post-LOCA containment debris load
]a"c The results of test CIBAP24 are plotted in
Figure 8-32.
The first concurrent addition of particulate, fiber, and chemical precipitates had little effect on the
head-loss across the full assembly. resulting in
]ac and held until termination criteria were again met, then flow sweeps were
performed to provide insight on the pressure drop dependence on flow rate.
As in the previous tests in this series, a flow reduction scheme was used to reduce the flow rate
commensurate with the increase in dP across the FA bundle (Figure 8-33). For this test the reduction
scheme was applied from the beginning of the test as the dP attributed to debris accumulation increased
during the concurrent additions. The test flow and dP tracked well with the performed flow reduction as
seen in Figure 8-32. [ ]a,c
As witnessed in test CIBAP22, the fiber accumulated around the bottom of the p-grid (Figure 8-35,
Figure 8-35, Figure 8-36) prior to accumulating around the bottom nozzle (Figure 8-37). This
accumulation began to appear just prior to the second addition and continued through the fourth addition
when a debris bed began to form around the edges of the bottom nozzle. Also witnessed in this
concurrent debris addition test was the accumulation of fibers in the middle of the first grid above the
p-grid (Figure 8-38) and along the bottom of the second grid above the p-grid (Figure 8-39). The
accumulation of debris in these areas is atypical when considering the other AP 1000 FA tests. It suggests
that individual fibers arriving at the FA bottom nozzle in lesser amounts may have a greater chance of
migrating through the fuel bundle. By the end of the test, the debris bed had taken on a smooth, rounded
appearance (Figure 8-40) and was not continuous around the edges of the bottom nozzle thus leaving
many break-through areas where flow is not impeded.
Even with a noticeable accumulation of fiber away from the bottom nozzle, the pressure drop increase
occurred almost exclusively at the bottom nozzle/p-grid location as in the other tests. This can be seen by
8-54 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
comparing the trace labeled "dP Upper" to the trace labeled "dP Lower" in Figure 8-32. The pressuredrop contribution from the upper assembly [ ]a,c
The average temperature for both the test column and the mixing tank during the test was, [ ]aC ThepH was measured throughout the test reaching a maximum pH of [ ]a This was within the allowable
range for the test (5 to 9), so any dissolution of the chemical product surrogate was insignificant. The
flow rate reached a steady state condition at]a'c held until termination criteria were met and flow sweeps were initiated.
8.23.1 Varying Initial Flow Rates
It has not been concluded whether varying the flow increases or decreases the head-loss. All of thesubsequent AP1000 FA tests have been conducted with varying flows because that is how the plant will
operate. The initial flow has been set at [ : ]a' since that flow seems to result in higher head-lossesthan other initial flows. The flow rate of [, ]a,c (comparingtests CIBAP20 and CIBAP23) for sequence debris addition. However, for concurrent debris addition
(comparing tests CIBAP22 and CIBAP24), [ ]pc butthe initial head-loss trend was more severe[ Based on this sensivity study the intial flow rate of [
]a,c will be used as most conservative for the remaining tests, either sequence or concurrent debrisadditions. The dPs for tests CIBAP20, CIBAP22 through CIBAP24 can be found in Table 8-1 forcomparison. asl
Figure 8-32 Head-Loss and Flow Rate History for Test CIBAP24
Revision 5 8-55
Revision 5 8-55
WCAP- 1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a..£
Figure 8-33 Flow Versus dP During Test CIBAP24
8-56 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 8-34 Accumulation of Debris at the Bottom of the P-Grid After Second Concurrent Debris
Addition in Test CIBAP24
a,c
Figure 8-35 Accumulation of Debris at the Bottom of the P-Grid After Third Concurrent Debris
Addition in Test CIBAP24
Revision 5 8-57
Revision 5 8-57
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-36 Accumulation of Debris at the Bottom of the P-Grid After Fourth Concurrent Debris
Addition in Test CIBAP24
a,c
7
Figure 8-37 Accumulation of Debris Around the Edge of the Bottom Nozzle After Seventh
Concurrent Debris Addition in Test CIBAP24
8-58 Revision 5
8-58 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 8-38 Accumulation of Debris in the Middle of the First Grid Above the P-Grid After the
Ninth Addition in Test CIBAP24
a,c
Figure 8-39 Accumulation of Debris Around the Bottom of the Second Spacer Grid After theNinthAddition in Test CIBAP24
Revision 5 8-59
Revision 5 8-59
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-40 Accumulation of Debris Around the Bottom Nozzle and P-Grid at the End of Test
CIBAP24 Prior to Flow Sweeps
8-60 Revision S
8-60 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.24 TEST #25 (CIBAP25)
This was the twenty-fifth FA debris loading head-loss experiments performed in the STC test facility for
the AP1000. []ac This experiment was performed according to test plan
STD-MCE-09-116 presented in Appendix C.]a,c
In this experiment, the debris loadings were based on a total AP 1000 post-LOCA containment debris load
]a"c The results of test
CIBAP25 are plotted in Figure 8-41. This test is similar to test CIBAP24 except that the chemicals are
I ]a,c
The first concurrent addition of particulate, fiber, and chemical precipitates had little effect on the head-
loss across the full assembly resulting in
]a,c
During this time, the test procedure was being followed to reduce the flow rate commensurate with, the
increase in dP attributed to debris accumulation within the FA.
Approximately 17 minutes following the eleventh chemical addition, a flow anomaly occurred that caused
a flow excursion in the loop. The upper flow meter which was controlling the flow in the loop, registered
a minimum flow of zero gpm which caused the flow to increase significantly. The increase in flow was
monitored by the lower flow meter; it registered a peak flow of[
]a~c Then the dP
reacted to the flow anomaly by falling to [ ]a,c
(Figure 8-41). Observations at the time of the flow anomaly indicated that large 'chunks' of the debris
formations around the bottom nozzle and p-grid broke off and were swept away.
]a,c
Even though the test experienced a significant anomaly, it was continued as planned. The flow rate was
]a"c All subsequent chemical additions were made.
After the final chemical addition, the prerequisite number of loop turnovers was performed; the data was
checked and found to meet the termination criteria. Flow sweeps were performed as written in the test
plan.
Revision 5 8-61
Revision 5 8.61
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
As seen in CIBAP24, the fiber accumulated around the bottom of the p-grid prior to accumulating around
the bottom nozzle. This accumulation began to appear just after the second addition and continued
through the fourth addition when a debris bed began to form around the edges of the bottom nozzle.
Even with a noticeable accumulation of debris away from the bottom nozzle, the pressure drop increase
occurred almost exclusively at the bottom nozzle/p-grid location as in the other tests. This can be seen by
comparing the trace labeled "dP Upper" to the trace labeled "dP Lower" in Figure 8-41. The pressure
drop contribution from the upper assembly was [ ]a,c
The average temperature for both the test column and the mixing tank during the test was [ ]ac The
pH was measured throughout the test reaching a maximum pH of [ ]a"' This was within the allowable
range for the test (5 to 9), so any dissolution of the chemical product surrogate was insignificant.
a,c
Figure 8-41 Head-Loss and Flow Rate History for Test CIBAP25
8-62 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
8.25 TEST #26 (CIBAP26)
This was the twenty-sixth FA debris loading head-loss experiments performed in the STC test facility for
the AP1O0O. [
STD-MCE-09-123 presented in Appendix C. []a,c This experiment was performed according to test plan
]a,c
In this experiment, the debris loadings were based on a total AP1000 post-LOCA containment debris load
]a"C The results of test
CIBAP26 are plotted in Figure 8-42. This test is similar to test CIBAP25 except that thea,c
The [ ]ac of concurrent debris additions of particulate, fiber, and chemical precipitates resulted
in a pressure differential across the full assembly of about [
]a,c The remaining five 'chemical-only' additions resulted in no furtherincreases in the recorded dP.
During this time, the test procedure was being followed to reduce the flow rate commensurate with the
increase in dP. By the fourteenth addition, the flow rate had been reduced from
]a~c Over the next hour and 15 minutes the steady state test criterion was again met and the
automated flow sweeps were initiated.
In this test, with the debris being added concurrently over 18 hours, the fiber barely began to accumulate
around the bottom of the p-grid after the third addition. After the fifth addition, with
]a,c
Even with a noticeable accumulation of debris away from the bottom nozzle upper bundle dP, the pressure
drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the other tests. This
can be seen by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower" in Figure 8-42.
The pressure drop contribution from the upper assembly [ ]a,c
Revision 5 8-63
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The average temperature for both the test column and the mixing tank during the test was [ ]a,c The
pH was measured throughout the test reaching a maximum pH of [ ]a C This was within the allowable
range for the test (5 to 9), so any dissolution of the chemical product surrogate was insignificant.
Figure 8-42 Head-Loss and Flow Rate History for Test CIBAP26
8-64 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.26 TEST #27 (CIBAP27)
This was the twenty-seventh of the FA debris loading head-loss experiments performed in the STC test
facility for the AP 1000. []aC This experiment was performed according to test
plan STD-MCE-09-125 presented in Appendix C. This test was a repeat of test CIBAP25, except that]a,c
In this experiment, the debris loadings were based on a reduced AP1000 post-LOCA containment debris
]a"C The results of
test CIBAP27 are plotted in (Figure 8-43). All debris was added concurrently.
The first concurrent addition of particulate, fiber, and chemical precipitates had little effect on the
head-loss acrossthe full assembly resulting in
]a,c
During this time, the test procedure was being followed to reduce the flow rate commensurate with the
increase in dP (Figure 8-44).
Similar to test CIBAP25, the fiber accumulated around the bottom of the p-grid (Figure 8-45) prior to
accumulating around the bottom nozzle (Figure 8-46). This accumulation begins to appear just after the
second addition and continues through the fourth addition when a debris bed begins to form around the
edges of the bottom nozzle (Figure 8-47). By the time of the sixth addition, the debris buildup along the
edges of the bottom nozzle and bottom of the p-grid are significant. Unlike test CIBAP25, there is no
visible accumulation of debris at the first spacer grid. After the seventh concurrent addition, the
accumulation of chemicals in the debris bed is easily seen (Figure 8-48) the debris bed still had rough
edges (Figure 8-49). Between the ninth (Figure 8-50) and twelfth (Figure 8-5 1) additions, the debris bedtook on a smoother appearance and there was a visible breakthrough of the debris bed along the lower left
and upper right edge of the bottom nozzle. Once these breakthrough areas were established, they
remained clear for the remainder of the test as seen in Figure 8-53. The dP peaked at []a"C By the time of the fourteenth addition, the edges of the debris bed (Figure 8-52)
were smooth,well-defined, and continued to thicken as the test progressed without a corresponding
increase in dP After the seventeenth addition, the dP was monitored until the steady state dP condition
wasmet. With all acceptance criteria met, flow sweeps were initiated to determine the pressure drop
dependence on flow rate. As seen in Figure 8-53 the debris was very thick and very smooth, yet did not
cause an increase in the steady state d.
Revision 5 8-65
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests. This can be seen by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower"in Figure 8-43. The pressure drop contribution from the upper assembly was approximately
]a,c
The average temperature for both the test column and the mixing tank during the test was [ ]a,c The
pH was measured throughout the test reaching a maximum pH of [ ]a c This was within the allowable
range for the test (5 to 9), so any dissolution of the chemical product surrogate was insignificant
Figure 8-43 Head-Loss and Flow Rate History for Test CIBAP27
a,c
8-66 Revision 5
8-66 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Figure 8-44 Flow Versus dP during Test CIBAP27
a,c
Figure 8-45 Accumulation of Debris Around the Bottom Nozzle and P-Grid after theThird Concurrent Addition in Test CIBAP27
Revision 5 8-67
Revision 5 8-67
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-46 Accumulation of Debris Around the Bottom Nozzle and P-Grid at the
Fourth Concurrent Addition in Test CIBAP27
ac
Figure 8-47 Accumulation of Debris Around the Bottom Nozzle and P-Grid at the
Fifth Concurrent Addition in Test CIBAP27
8-68 Revision 5
8-68 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-48 Accumulation of Debris Around the Bottom Nozzle and P-Grid 30 Minutes into the
Fifth Concurrent Addition in Test CIBAP27
a,c
Figure 8-49 Accumulation of Debris Around the Bottom Nozzle and P-Grid 30 Minutes into theNinth Chemical Addition in Test CIBAP27
Revision 5 8-69
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Figure 8-50 Accumulation of Debris Around the Bottom Nozzle and P-Grid at the Time of theTenth Chemical Addition in Test CIBAP27
a,c
Figure 8-51 Accumulation of Debris Around the Bottom Nozzle and P-Grid 30 Minutes into the
Twelfth Chemical Addition in Test CIBAP27
8-70 Revision 5
8-70 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-52 Accumulation of Debris Around the Bottom Nozzle and P-Grid 15 Minutes After the
Fourteenth Chemical Addition in Test CIBAP27
a,c
Figure 8-53 Accumulation of Debris Around the Bottom Nozzle and P-Grid Prior to Flow Sweeps
in CIBAP27
Revision 5 8-71
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
8.27 TEST #28 (CIBAP28)
This was the twenty-eighth of the FA debris loading head-loss experiments performed in the STC testfacility for the AP 1000.
]a"C This experiment was performed according to test plan
STD-MCE-09-132. This test was a repeat of test CIBAP27
ac
In this sensitivity experiment, the debris loadings were based on a reduced AP 1000 post-LOCAcontainment debris load of
]aC The results of test CIBAP28 are plotted in Figure 8-54. All debris was added
concurrently.
The first concurrent addition of silicon carbide particulate, fiber, and chemical precipitates had little effecton the head-loss across the full assembly resulting in a
a,c
During this time, the test procedure was followed using the procedure information to reduce the flow ratecommensurate with the increase in dP.
Similar to test CIBAP25, the fiber accumulated around the bottom of the p-grid prior to accumulating
around the bottom nozzle. This accumulation beganto appear after the second addition and continuedthrough the fourth addition when a debris bed began to form around the edges of the bottom nozzle. Bythe time of the sixth addition, the debris buildup along the edges of the bottom nozzle and bottom of thep-grid were significant. Unlike test CIBAP25, there was no visible accumulation of debris at the firstspacer grid. After the seventh and last concurrent addition, the accumulation of chemicals in the debris
bed still had rough edges. Between the ninth and twelfth additions, the debris bed took on a smootherappearance. The dP peaked at [ ]a'c By the time of the fourteenthaddition, the edges of the debris bed were smooth, well-defined, and continued thicken as the testprogressed without a corresponding increase in dP. After the seventeenth addition, the dP was monitoreduntil the steady state dP condition was met. With all acceptance criteria met, flow sweeps were initiatedto determine the pressure drop dependence on flow rate.
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests. This can be seen by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower"in Figure 8-54. The pressure drop contribution from the upper assembly was approximately
]ac
8-72 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
The average temperature for both the test column and the mixing tank during the test was [ ]a,c ThepH was measured throughout the test and reacheda maximum pH of [ ]a,c This was within the
allowable range for the test (5 to 9), and therefore any dissolution of the chemical product surrogate was
insignificant.
Figure 8-54 Head-Loss and Flow Rate History for Test CIBAP28
as,
Revision 5 R-73
Revision 5 R-73
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.28 TEST #29 (CIBAP29)
This was the twenty-ninth FA debris loading head-loss experiments performed in the STC test facility forthe AP1000. [
]a"C This experiment was performed according to test plan
STD-MCE-09-133 This test was a repeat of test CIBAP27, except the [
ac
In this experiment, the debris loadings were based on a reduced AP1000 post-LOCA containment debrisload of[
]a,' The results oftest CIBAP29 are plotted in Figure 8-55. All debris was added concurrently.
The first concurrent addition of particulate, fiber, and chemical precipitates had little effect on the head-loss across the full assembly resulting in a
ac
During this time, the test procedure was followed using the procedure information to reduce the flow ratecommensurate with the increase in dP.
Similar to previous concurrent debris addition tests, the fiber accumulated around the bottom of the p-gridprior to accumulating around the bottom nozzle. This accumulation begans to appear just after the secondaddition and continued through the fourth addition when a debris bed began to form around the edges ofthe bottom nozzle. Similar to test CIBAP22, there was visible accumulation of debris at the secondspacer grid, but in this test there was very little on the first spacer grid. By the time of the sixth addition,the debris buildup along the edges of the bottom nozzle and bottom of the p-grid were significant. Afterthe seventh concurrent addition, the accumulation of chemicals in the debris bed was easily seen and thedebris bed still had rough edges. The dP peaked at [ ]"C By thetime of the fifteenth addition, the edges of the debris bed were smooth, well-defined, and continued tothicken as the test progressed without a corresponding increase in dP After the seventeenth and finaladdition, the dP was monitored until the steady state dP condition ws met. With all acceptance criteriamet, flow sweeps were initiated to determine the pressure drop dependence on flow rate. The debris wasthick and smooth at the time of the flow sweeps, yet did not cause an increase in the steady state dP.
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in theother tests. The accumulation of debris in the second spacer grid showed a
a,c
8-74 Revision 5
8-74 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The average temperature for both the test column and the mixing tank during the test was [ ]rc The
pH as measured throughout the test reaching a maximum pH of [ ]aC This was within the allowable
range for the test (5 to 9), so any dissolution of the chemical product surrogate was insignificant.
Figure 8-55 Head-Loss and Flow Rate History for Test CIBAP29
Revision 5 8-75
Revision 5 8-75
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.29 TEST #30 (CIBAP30)
This was the thirtieth FA debris loading head-loss experiments performed in the STC test facility for theAPIO00. [
]a.c This experiment was performed according to test plan STD-MCE-09-135
presented in Appendix C. [a,c
In this experiment, the debris loadings were based on a reduced AP 1000 post-LOCA containment debrisload of[
]a.c The results of
test CIBAP30 are plotted in Figure 8-56.
The first concurrent addition of silicon carbide particulate, fiber, and chemical precipitates had little effecton the head-loss across the full assembly resulting in a
a,c
During this time, the test procedure was being followed using the procedure information to reduce theflow rate commensurate with the increase in dP.
Similar to previous tests, the fiber accumulated around the bottom of the p-grid prior to accumulatingaround the bottom nozzle (Figure 8-57). This accumulation began to appear just after the second additionand continued through the fourth addition, when a debris bed began to form around the edges of thebottom nozzle Figure 8-58. By the time of the fifth addition (Figure 8-59), the debris buildup along theedges of the bottom nozzle and bottom of the p-grid were apparent. Unlike test CIBAP29, there wasminimal accumulation of debris at the first and second spacer grids early in the test. After the seventhconcurrent addition, the accumulation of chemicals in the debris bed was observed and the debris bed stillhad rough edges. Between the ninth and twelfth additions, the debris bed took on a smoother appearance(Figure 8-60 and Figure 8-61) as the chemical coated the debris bed. The dP peaked at [
]a" Between the fifteenth and sixteenth additions, the dP dropped again due toa break though within the debris bed. After the seventeenth addition (Figure 8-62), the dP was monitoreduntil the steady state dP condition was met. With all acceptance criteria met, flow sweeps were initiatedto determine the pressure drop dependence on flow rate. Near the end of the flow sweeps, the debris wasthick and smooth (Figure 8-63), yet did not cause an increase in the steady state dP.
Of note in this test is the initial accumulation of debris along the edge of the upper left of the bottomnozzle opening as seen in Figure 8-58. By the time of the fifth addition (Figure 8-59), an opening beganto appear along the upper left edge. By the ninth addition, a clean path was established (Figure 8-60) andit remained open until test termination (Figure 8-63).
8-76 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests. This can be seen by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower"
in Figure 8-56.a,c
Figure 8-56 Head-Loss and Flow Rate History for Test CIBAP30
Revision 5 8-77
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
Figure 8-57 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Third Concurrent Addition in Test CIBAP30
a,c
Figure 8-58 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Fourth Concurrent Addition in Test CIBAP30
8-78 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Figure 8-59 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After theFifth Concurrent Addition in Test CIBAP30
a,c
Figure 8-60 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Ninth Chemical Addition in Test CIBAP30
Revision 5 8-79
Revision 5 8-79
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE, NON-PROPRIETARY CLASS 3 API000
a,c
Figure 8-61 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Twelfth Chemical Addition in Test CIBAP30
a,c
Figure 8-62 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes After the
Seventeenth Chemical Addition in Test CIBAP30
8-80 Revision 5
8-80 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
7
Figure 8-63 Accumulation of Debris at the Bottom Nozzle and P-Grid Near the End of the FlowSweeps in Test CIBAP30
Revision 5 8-81
Revision 5 8-81
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.30 TEST #31 (CIBAP31)
This was the thirty-first of the FA debris loading head-loss experiments performed in the STC test facility
for the AP 1000. With the debris load and chemical precipitate tested, the peak head-loss recorded for this
test was
]a'c Theresults of test CIBAP31 are plotted in Figure 8-64.
[
]ac
During this time, the test procedure was being followed to reduce the flow rate commensurate with the
increase in d.
Similar to previous tests, the fiber accumulated around the bottom of the p-grid prior to accumulatingaround the bottom nozzle. This accumulation began to appear just after the second addition andcontinued through the fourth addition when a debris bed began to form around the edges of the bottomnozzle. By the time of the fifth addition, the debris buildup along the edges of the bottom nozzle and
bottom of the p-grid were apparent. There was little accumulation of debris at the first and second spacergrids early in the test. After the seventh concurrent addition, the accumulation of chemicals in the debrisbed was observed and the debris bed still had rough edges. Between the ninth and twelfth additions, thedebris bed took on a smoother appearance as the chemical coated the debris bed on the bottom nozzleonly. The debris bed on the bottom of the p-grid was not as smooth and the accumulation was moresporadic along the grid. By the time of the ninth addition, the edges of the debris bed were smooth, well-defined and the dP continued to increase. It continued thicken as the test progressed with only a smallincrease in d. Between the eleventh and thirteenth additions the dP dropped due to a breakthroughwithin the debris bed, but the dP eventually climbed back up. After the seventeenth addition, the dP
became steadier and was monitored until the steady state dP condition was met. []a"c With all acceptance criteria met, flow sweeps were initiated to
determine the pressure drop dependence on flow rate. Near the end of the flow sweeps, the debris bedwas thick and smooth, yet it did not cause an increase in the steady state d.
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in theother tests. This can be seen by comparing the trace labeled "dP Upper" to the trace labeled "dP Lower"
in Figure 8-64. [ac
8-82 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The average temperature for both the test column and the mixing tank during the test was [ ]a,c
The pH was measured throughout the test reaching a maximum pH of [ ]a C This was within theallowable range for the test (5 to 9), so any dissolution of the chemical product surrogate wasinsignificant.
ac
Figure 8-64 Head-loss and Flow Rate History for Test CIBAP31
Revision 5 8-83
Re'eisqio'n 5 8-83
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
8.31 TEST #32 (CIBAP32)
This was the thirty-second of the FA debris loading head-loss experiments performed in the STC testfacility for the AP1000. [
]a"C This experiment was performed according to test plan
STD-MCE-10-03. This test was an exact repeat of test CIBAP30.
]a~c The results of test CIBAP32 are plotted in Figure 8-65.[ ]~
]ac
During this time, the test procedure was being followed to reduce the flow rate commensurate with theincrease in d.
Similar to previous tests, the fiber accumulated around the bottom of the p-grid prior to accumulatingaround the bottom nozzle. This accumulation began to appear just after the second addition andcontinued through the fourth addition when a debris bed began to form around the edges of the bottomnozzle. By the time of the fifth addition, the debris buildup along the edges of the bottom nozzle andbottom of the p-grid were apparent. Unlike test CIBAP3 1, the debris collected evenly across the bottomnozzle and bottom of the p-grid. There was very little accumulation of debris at the first and secondspacer grids early in the test. After the seventh and last concurrent addition, the accumulation ofchemicals in the debris bed was observed and the debris bed still had rough edges. Between the ninth andtwelfth additions, the debris bed took on a smoother appearance as the chemical coated the debris bed.By the time of the fourteenth addition, the edges of the debris bed were smooth and well-defined. Itcontinued to thicken as the test progressed with only a small increase in dP, showing more of an increasethan CIBAP3 1. Between the fourteenth and sixteenth additions, the dP dropped again due to abreakthrough within the debris bed. [ ]ac
The dP was monitored and continued to rise steadily until the last addition. At that point, the dP finallybecame steady. With all acceptance criteria met, flow sweeps were initiated to determine the pressure
drop dependence on flow rate. Near the end of the flow sweeps, the debris bed was thick and smooth, yet
it did not cause an increase in the steady state dP.
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests. The accumulation of debris in the second spacer grid shows [
8-84 Revision 5
8-84 I Revision 5
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
]a,c
The average temperature for both the test column and the mixing tank during the test was [ ]ac
The pH was measured throughout the test reaching a maximum pH of [ ]"' This was within the
allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate was
insignificant.
a,c
Figure 8-65 Head-loss and Flow Rate History for Test CIBAP32
Revision 5 8-85
Revision 5 8-85
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
8.32 TEST #33 (CIBAP33)
This was the thirty-third of the FA debris loading head-loss experiments performed in the STC test facility
fortheAPOOO. []aC This experiment was performed according to test plan STD-MCE-
10-04. This test was an exact repeat of test CIBAP30.
]apC All debris was added concurrently.
ac
Throughout the test, the test procedure was followed using the procedure information to reduce the flowrate commensurate with the increase in dP.
Similar to previous tests, the fiber accumulated around the bottom of the p-grid prior to accumulatingaround the bottom nozzle. This accumulation began to appear just after the second addition andcontinued through the fourth addition when a debris bed began to form around the edges of the bottomnozzle. By the time of the fifth addition the debris buildup along the edges of the bottom nozzle and
bottom of the p-grid were apparent. There was very little accumulation of debris at the first and secondspacer grids early in the test. After the seventh concurrent addition, the accumulation of chemicals in thedebris bed was observed and the debris bed still had rough edges. Between the ninth and twelfthadditions, the debris bed took on a smoother appearance as the chemical coated the debris bed. It
continued to thickern as the test progressed with only a [ ]"' Between the fifteenthand sixteenth additions, the dP dropped again due to a breakthrough within the debris bed. By the time of
the seventeenth addition, the edges of the debris bed were smooth and well-defined. After the seventeenthaddition, the dP was monitored until the steady state dP condition was met. With all acceptance criteriamet, flow sweeps were initiated to determine the pressure drop dependence on flow rate. Near the end ofthe flow sweeps, the debris bed was thick and smooth, yet it did not cause an increase in the steady state
dP.
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests.
a'c
8-86 Revision 5
8-86 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
The average temperature for both the test column and the mixing tank during the test was []"'
The pH was measured throughout the test reaching a maximum pH of [ ]a.C This was within theallowable range for the test (5 to 9), so any dissolution of the chemical product surrogate wasinsignificant.
a,c
Figure 8-66 Head-loss and Flow Rate History for Test CIBAP33
Revision 5 8-87
Revision 5 8-87
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.33 TEST #34 (CIBAP34)
This was the thirty-fourth of the FA debris loading head-loss experiments performed in the STC testfacility for the AP 1000. With the debris load and chemical precipitate tested the peak head-loss recordedfor this test was [ ]"C This experiment was performed according to test plan STD-MCE-10-05. This test was a repeat of CIBAP30, but with a modified flow profiling scheme. InCIBAP30 and other recent tests,
]ac At the end of the test, the flow wasvaried more quickly to determine the pressure drop dependence on flow rate. Thus, this experimentincluded flow profiling both at the end of the test and also at earlier times when peak pressure drops wereoften experienced.
The peak pressure of
]ac In this experiment the debris loadings were based on a reduced AP 1000 post-LOCA
containment debris load of 180 pounds, consisting of 6.6 pounds of fiber, 173.4 pounds of particulatesand 57 pounds of chemical precipitates (Reference 5).
]a,c The results of test CIBAP34 are plotted in Figure 8-67. All debris
was added concurrently.
]a,c
Throughout the remainder of the test, after the first addition, the test procedure was followed using theinformation in the test plan to reduce the flow rate commensurate with the increase in dP. This procedurewas utilized for [
pac
Similar to previous tests, the fiber accumulated around the bottom of the p-grid prior to accumulating
around the bottom nozzle. This accumulation began to appear just after the second addition and
continued through the fourth addition (Figure 8-68 and Figure 8-69) when a debris bed began to form
around the edges of the bottom nozzle. By the time of the fifth addition, the debris buildup along the
edges of the bottom nozzle and bottom of the p-grid were apparent. After the seventh concurrent
addition, the accumulation of chemicals in the debris bed was observed and the debris bed still had roughedges. Between the ninth and twelfth additions (Figure 8-70 and Figure 8-71), the debris bed took on asmoother appearance as the chemical coated the debris bed. It continued to thicken as the test progressed.Between the thirteenth and fourteenth additions, the dP dropped slightly but recovered after the fourteenthaddition. [ ]a,,c In tests CIBAP27, CIBAP29,
CIBAP30, CIBAP31, CIBAP32 and CIBAP33 the dP peaked after the twelfth addition (between the
8-88 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
twelfth and seventeenth additions). By the time of the seventeenth addition, the edges of the debris bed
were smooth and well-defined. After the seventeenth addition, the dP was monitored until the steady state
dP condition was met. With all acceptance criteria met, flow sweepswere initiated to determine the
pressure drop dependence on flow rate. Near the end of the flow sweeps, the debris bed was thick and
smooth, yet it did not cause an increase in the steady state dP (Figure 8-72).
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests.
]a,c
The average temperature for both the test column and the mixing tank during the test was [ ]a,c
The pH was measured throughout the test reaching a maximum pH of [ ]a c This was within the
allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate was
insignificant.
a,c
Figure 8-67 Head-loss and Flow Rate History for Test CIBAP34
Revision 5 8-89
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 8-68 Accumulation of Debris at the Bottom Nozzle and P-Grid Right before the Fourth
Addition in Test CIBAP34 a,c
Figure 8-69 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes after the Fourth
Concurrent Addition in Test CIBAP34
8-90 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIOcO
a,c
Figure 8-70 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes after the Ninth
Chemical Addition in Test CIBAP34
a,c
Figure 8-71 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes after theTwelfth Chemical Addition in Test CIBAP34
Revision 5 8-91
Revision 5 8-91
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Figure 8-72 Accumulation of Debris at the Bottom Nozzle and P-Grid 30 Minutes after the Last
Chemical Addition in Test CIBAP34
8-92 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.34 TEST #35 (CIBAP35)
This was the thirty-fifth of the FA debris loading head-loss experiments performed in the STC test facility
for the AP1000. The goal of this test was to" observe the effects of adding debris to a model FA underreverse flow conditions that might exist in an AP 1000 reactor after a hot-leg break. The test evaluated the
distribution of debris blockages within the top portion of the assembly, and the relationship between
pressure and flow. To model AP 1000 behavior on a hot-leg break, further testing of debris blockage with
reverse flow was needed. With the debris load and chemical precipitate tested, the peak head-loss
recorded for this test was ]a,c
This experiment was performed according to test plan STD-MCE-10-07. Debris was introduced slowly
with reverse flow. The flow rate started out at the maximum pump flow of approximately [ ]a,c
The maximum flow was maintained until the pressure drop due to debris reached a value of
]ac At that point, the flow was automatically controlled to maintain a pressure drop of
0.85 psi across the assembly.
In this sensitivity experiment, the debris loadings were based on a reduced AP 1000 post-LOCA
containment debris load of 180 pounds, consisting of 6.6 pounds of fiber, 173.4 pounds of particulates
and 57 pounds of chemical precipitates (Reference 5).
]aC The results of test
CIBAP35 are plotted in Figure 8-73. All debris was added concurrently.
The first concurrent addition of silicon carbide particulate, fiber, and chemical precipitates affected the
head-loss across the full assembly more than the first addition affected the dP of CIBAP31-34 up-flow
tests. Immediately after the first addition, the dP resulted in]aC The
subsequent concurrent additions of the combined three debris types over next five hours resulted in
increases ofac
However, this test was a scoping test for the, upcoming down-flow tests.
Unlike the previous tests, the fiber accumulated around top nozzle because of reverse flow. The water
flowed entered through a 1.5" nozzle at the top of the test column and flowed downward and exited
through a port at the bottom of the column. The flow at the top of the column passed through an acrylic
structure which simulated the upper internals.
This accumulation began to appear on the top of the top grid after the first addition. After the second
concurrent addition the dP peaked at [ cc After the third concurrent addition, the bed on the top
grid became thicker and showed a smoother, appearance. Also, during after the third addition it becameapparent that debris was settling on the bottom of the top nozzle and was forming a bed. The dP at this
time became steady but the flow began to decrease quickly. By the sixth addition there was a noticeable
bed on an intermediate grid. The bed on the top grid thickened, causing flow resistance.
Revision 5 8-93
Revision 5 8-93
,1
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
The average temperature for both the test column and the mixing tank during the test was ]a,c
The pH was measured throughout the test,reaching a maximum pH of [ ]"' This was within the
allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate was
insignificant.
ac
Figure 8-73 Head-loss and Flow Rate History from Test CIBAP35
8 -94 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
8.35 TEST #36 (CIBAP36)
This was the thirty-sixth of the FA debris loading head-loss experiments performed in the STC test facility
for the AP 1000. With the debris load and chemical precipitate tested, the peak head-loss recorded for this
test was [ ]a C This experiment was performed according to test plan STD-MCE-10-
10. This test was a repeat of CIBAP30, with the difference being that chemicals were added to the loop to
simulate reactor coolant and the loop was heated.
]a C The results of test CIBAP36 are plotted in (Figure 8-74.) All debris was
added concurrently. The schematic of the test loop for CIBAP36 can be found in Figure 4-3.
The first concurrent addition of silicon carbide particulate, fiber, and chemical precipitates had little effect
on the head-loss across the full assembly [ ]ac One hour later the secondconcurrent addition increased the pressure' drop to [ ]a'• The subsequent concurrent additions of
the combined three debris types over next five hours resulted in increases of [
a,c
Throughout the test, the test procedure was followed using the procedure information to reduce the flowrate commensurate with the increase in d.
Similarto previous tests, the fiber accumulated around the bottom of the p-grid prior to accumulatingaround the bottom nozzle. This accumulation began to appear just after the second addition andcontinued through the third addition when a debris bed began to form around the edges of the bottom
nozzle Figure 8-75. By the time of the fifth addition, the debris buildup along the edges of the bottomnozzle and bottom of the p-grid were apparent. The accumulation of the debris on the bottom nozzle
formed a thin bed, but covered the entire surface at the ninth addition (Figure 8-76). The debris that wascollected on the bottom of the p-grid collected mainly to one side and the debris was clumped together.
After the eleventh addition, the debris bed on the bottom nozzle took on a smoother appearance as the
chemical coated the bed. It continued to thicken as the test progressed with only a small increase in dP(Figure 8-77 and Figure 8-78). Between the fifteenth and sixteenth additions, the dP dropped again due to
a breakthrough within the debris bed. After the seventeenth addition, Figure 8-79, the dP was monitored
until the steady state dP condition was met. At this time the edges of the debris bed were smooth and
well- defined. With all acceptance criteria met, flow sweeps were initiated to determine the pressure drop
dependence on flow rate. Near the end of the flow sweeps, the debris bed was thick and smooth, yet it didnot cause an increase in the steady state dP.
Revision 5 8-95
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Overall, adding the chemicals to simulate reactor coolant and increasing the loop temperature to [ ],,c
resulted in a lower dP compared to the previous tests.
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests. The accumulation of debris in the
ac
I
p,c
a,c
21
Figure 8-74 Head-loss and Flow Rate History for Test CIBAP36
8-96 Revision 5
8-96 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API O00
a,c
Figure 8-75 Accumulation of Debris at the p-grid 30 Minutes after the Third Concurrent Addition
in Test CIBAP36
ac
Figure 8-76 Accumulation of Debris at the p-grid 30 Minutes after the Ninth Chemical Addition
in Test CIBAP36
Revision 5 8-97
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Figure 8-77 Accumulation of Debris at the p-grid 30 Minutes after the Fifteenth Chemical Addition
in Test CIBAP36
a,c
Figure 8-78 Accumulation of Debris at the Third Grid 30 Minutes after Fifteenth Chemical in Test
CIBAP36
8-98 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Figure 8-79 Accumulation of Debris at the p-grid at the End of the Test CIBAP36
Revision 5 8-99
Revision 5 8-99
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.36 TEST #37 (CIBAP37)
This was the thirty-seventh of the FA debris loading head-loss experiments performed in the STC testfacility for the AP1000. With the debris load and chemical precipitate tested, the peak head-loss recordedfor this test was [ ]pc This experiment was performed according to test plan STD-MCE- 10-11. The test was conducted at a temperature of [
]axc The results of test
CIBAP37 are plotted in (Figure 8-80). All debris was added concurrently. This test is a repeat ofCIBAP36. CIBAP37 was conducted to evaluate the effects of TSP, Boric Acid and high temperatureexperimenting on repeatability. The schematic of the test loop for CIBAP37 is found in Figure 4-3.
]a,• after the
eleventh addition Throughout the test, the test procedure was followed using the procedure information toreduce the flow rate commensurate with the increase in dP.
Similar to previous tests, the fiber accumulated around the bottom of the p-grid prior to accumulatingaround the bottom nozzle. This accumulation began to appear just after the first addition and continuedthrough the fourth addition when a debris bed began to form around the edges of the bottom nozzle. Bythe time of the fifth addition, the debris development along the edges of the bottom nozzle and bottom ofthe p-grid were apparent. Debris started to collect on the third grid from the bottom nozzle, which wasunlike the previous tests. After the ninth addition, the debris bed on the p-grid took on a smootherappearance as the chemical coated the bed. [
]a,c After thethirteenth addition, the chemical on the bed of the p-grid became more apparent. It continued to thickenas the test progressed with only a small increase in dP. After the seventeenth addition, the dP wasmonitored until the steady state dP condition was met. At this time the edges of the debris bed weresmooth and well-defined. With all acceptance criteria met, flow sweeps were initiated to determine thepressure drop dependence on flow rate. Near the end of the flow sweeps, the debris bed was thick andsmooth, yet [ ]a,c
]ac
8-100 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The pressure drop increase occurred almost exclusively at the bottom nozzle/p-grid location as in the
other tests. I
]a,c
II
p ac
a,c
Figure 8-80 Data Plot from Test CIBAP37 Baseline dP Corrected to Zero
Revision 5 8-101
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.37 TEST #38 (CIBAP38)
This was the thirty-eighth of the FA debris loading head-loss experiments performed in the STC test
facility for the AP 1000. This experiment was performed according to test plan STD-MCE- 10-13. The
goal of this test was to observe the effects of adding debris to a model FA under simulated hot-leg break
conditions. With the debris load and chemical precipitate tested, the peak head-loss recorded for this test
was [ ]ac The conditions simulated in this test were reverse flow, followed by upward
flow with boiling. The location of the debris within the assembly and its movement were monitored aswell as how the debris affected coolant flow within the assembly.
]a,c The schematic of the test loop can be found in Figure 4-2 for the
down-flow portion of the test and Figure 4-4 for the up-flow with simulating boiling.
In an actual hot-leg LOCA in an AP1000, the flow in the upper part of the core is expected to oscillate
over several minutes. When the down-flow in a low-power assembly becomes low, the steam generated
rises upwards. The production of steam, together with other thermal hydraulic forces acting on the
system, would result in a change in flow direction from a downward to an upward direction. This flow
reversal and its effect on a debris bed were explored in test CIBAP38.
ac
I
]a,c
I
]ac The results of test CIBAP38are plotted in Figure 8-81.
[
8-102 Revision 5
8-102 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
]a,c
The average temperature for both the test column and the mixing tank during the test was [
The pH was measured throughout the test reaching a maximum pH of [ ]a,c This was within the
allowable range for the test (5 to 9), so any dissolution of the chemical product surrogate was
insignificant.
Figure 8-81 Data Plot from Test CIBAP38 Baseline dP Corrected to Zero
a,c
a,c
Revision 5 8-103
Revision 5 8-103
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Figure 8-82 Photograph of the Top-Grid 59 Minutes after the First Concurrent Addition in Test
CIBAP38
ac
Figure 8-83 Photograph of the Top-Grid after Stable Air and Water Flow are Achieved in Test
CIBAP38
8-104 Revision 5
8-104 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
Figure 8-84 Photograph of the Top Grid Seconds before Simulating Boiling Began
a,c
Figure 8-85 Photograph of the Top Grid 6 Seconds after Simulated Boiling Began
Revision 5 8-105
Revision 5 8-105
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Figure 8-86 Photograph of the Top Grid 12. Seconds after Simulated Boiling Began
a,c
Figure 8-87 Photograph of the Top Grid 19 Seconds after Simulated Boiling Began
8-106 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Figure 8-88 Photograph of the Top Grid 24 Seconds after Simulated Boiling Began
a,c
Figure 8-89 Photograph of a Spacer 51 Minutes after First Addition (SiC) During Up-flow in
Test CIBAP38
Revision 5 8-107
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 8-90 Photograph of the Top-Grids 51 Minutes after First Addition (SiC) During Up-flow in
Test CIBAP38
a,c
Figure 8-91 Photograph of the Top-Grid 51 Minutes after First Addition (SiC) During Up-flow in
Test CIBAP38
8-108 Revision 5
8-108 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
I
Figure 8-92 Photograph of the p-grid after Flow Sweeps in Test CIBAP38
Revision 5 8-109
Revision 5 9-109
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.38 TEST #39 (CIBAP39)
This was the thirty-ninth of the FA debris loading head-loss experiments performed in the STC test
facility for the AP1000. With the debris load and chemical precipitate tested, the peak head-loss recorded
for this test was roughly
]apc This experiment was performed according to test plan, STD-MCE-
10-15, which simulated boiling during the whole experiment.
The goal of this test was to observe the effects of adding debris to a model FA under simulated hot-leg
break conditions. The conditions simulated in this test were upward flow of coolant with boiling. Thelocation of the debris within the assembly and its movement were monitored as well as how the debris
affected coolant flow within the assembly.
After a hot-leg break in the AP1000, debris may be transported into the break and then into the upperplenum of the reactor. From there it may be carried deeper into the core by coolant which flows downthrough the outer, low-power assemblies and then up through the central, high-power assemblies. The
down-flow is expected to penetrate downward about 25 to 30% of the core height (Reference 3). Debrismay collect at spacer grids during up-flow causing a pressure drop and reducing flow of coolant. In an
actual hot-leg LOCA in an AP 1000, the flow in the upper part of the core is expected to oscillate over
several minutes. When the down-flow in a low-power assembly becomes low, the steam generationincreases. The production of steam, together with other thermal hydraulic forces acting on the system,
would result in a change in flow direction from the downward to upward direction. This flow reversaland its effect on a debris bed were explored in test CIBAP38.
]a," The schematic of the test loop can be found in Figure
4-4.
]apc The results of test CIBAP39 are plotted in (Figure 8-93). All debris was added
concurrently and two chemical additions were added at the end.
ac
8-110 Revision 5
8-110 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004
W NWESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Flow profiling was performed at the beginning of the test before the debris was added (clean loop).
Forty minutes after each debris addition, another flow sweep was performed. [I ],C This was done to determine if any-
debris blockage or flow resistance was present vs. a clean FA. The profiling was done without air flow to
increase the sensitivity of the measurement, since pressure readings during the air flow were highly
variable. Flow sweeps were done instead of maintaining a constant flow with no air flow, because
measurement of the dP variation with flow ýis not sensitive to zero shifts in the dP sensors. Air can be
trapped in the dP tap lines, which if not completely removed, will cause an erroneous dP reading due to
the change in static head. The change in pressure during a flow profile, however, will not be affected by
trapped air.
There was a significant dP increase between the clean assembly profiling and assembly profiling after
debris addition. The maximum dP increase in going from [ ]a,C occurred during the first flow
profiling after debris addition. [ ]a" However, this change in pressure drop
observed during profiling after debris is insignificant in comparison to our available head of [ pac
]a,c
The average temperature for both the test column and the mixing tank during the test was [ ]a,
The pH was measured throughout the test reaching a maximum pH of ]a'c This was within the
allowable range for the test (5 to 9), so any, dissolution of the chemical product surrogate was
insignificant.
Figure 8-93 Data Plot from Test CIBAP39 Baseline dP Corrected to Zero
ac
Revision 5 8-111
Revision 5 8-111
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 8-94 Photograph of the Spacer Grid 34 Minutes after the First Concurrent Addition in
Test CIBAP39 a,c
Figure 8-95 Photograph of the Spacer Grid 34 Minutes after the Second Concurrent Addition in
Test CIBAP39
8-112 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-96 Photograph of the Spacer Grid 30 Minutes during Water and Air Flow Stabilization
for 60 Minutes after the Last Chemical Addition
a,c
Figure 8-97 Photograph during Water and Air Flow Stabilization for 60 Minutes after the Last
Chemical Addition
Re'vision 5 8-113
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-98 Photograph of the Top-Grid during Water and Air Flow Stabilization for 60 Minutes
after the Last Chemical Addition a,c
Figure 8-99 Photograph of the Spacer Grid during the Last Flow Profile in Test CIBAP39
8-114 Revision 5
8-114 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
8.39 PRESSURE DIFFERENTIAL WITH FLOW
The results obtained from the AP1000 FA tests have been used to provide an experimental basis to
determine the dependence of the pressure loss through the FA on the flow rate once a debris bed was
formed as described in Section 5.1. The following three subsections describe this evaluation. The first
shows the analysis of flow/dP data from the later portions of each test when the bed dP stopped changing.The second subsection evaluates the stability of the bed resistance during these times. The third
subsection evaluates the flow/dP at the peak dP condition and compares it with the stable bed behavior.
8.39.1 Variation of dP with Variation of Flow and End-of-Test Data
Tests CIBAPI8 through CIBAP34, CIBAP36 and CIBAP37 were performed with flow sweeps at the end
of each test to investigate the dependence of the loss of pressure through the FA on the flow rate asdiscussed in Section 5.0. Tests CIBAP08 through CIBAPI 1 were performed with oscillating flow rates in
order to simulate the long-term behavior of the AP1000 as discussed above in the test results Section 8.0.
The oscillatory nature of tests CIBAP08 through CIBAP II provides another way to investigate the
dependence of the loss of pressure through the FA on the flow rate.
The pressure drop (dP) versus flow relationship plots for tests CIBAP08 through CIBAP 1I and tests
CIBAP 18 through CIBAP30 are presented in Reference 14, and test CIBAP31 through CIBAP34,CIBAP36 and CIBAP37 are presented in Reference 15. Examples from each of the test series are
provided below.
Tests CIBAP09 and CIBAPI 1 were sequential addition tests performed with oscillating flow between
]a,,C (Section 8.9, Figure 8-8 and Section 8.11, Figure 8-10). The resulting dP vs.
flow curves are shown in Figure 8-100 and Figure 8-101 along with the pdwer curve fit that provides the
exponent used in Eq. 5.1.1 to define the relationship of the test data to the acceptance criterion of 4.1 psid
(Section 5.0). For tests CIBAP08 through CIBAP 11 the data was taken after all debris had been added
and the flow and dP had stabilized.
The "hysteresis" shown in Figure 8-100 and Figure 8-101 is unique to all of the oscillating flow tests.
The two dense clouds of points at the bottom and at the top of the loop are the data collected when the
flow rate was constant at [ ]aC respectively (steady state conditions). These data fitthe power law relationship well as is shown in Figure 8-100 and Figure 8-101. The data collected during
the increasing and decreasing flow rate phase of each cycle are distributed along a loop contour. Inparticular (see Figure 8-102):
* During the flow increase from r ]a,c the data follows the upper part of the loop,and,
* when the flow rate returns to [ ]apc the data follows the lower part of the loop.
Revision 5 8-1 15
Reviqin•n 5 8-115
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
This behavior is related to an instrumentation time delay. The output signal of the flow meter is the
average of five consecutive samples. This is not a running average; the next output signal is the average
of the next five samples. The sample frequency of the flow meter is [ ]a,c
Thus, the flow meter provides an output signal:
I pc
Also, the data acquisition computer samples the flow meter [
]a,c when the changes in flow rate are slow as in the case of the flow sweeps performed in
tests CIBAP18 through CIBAP34, CIBAP36 and CIBAP37. Therefore, during the rapid changes such asin test CIBAP08 through test CIBAP 11, a hysteresis which is strictly an artifact of the sampling of the
instruments appears in the data.a,c
Figure 8-100 dP Versus Flow For Test CIBAP09
8-116 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-101 dP Versus Flow For Test CIBAP1l
a,c
I
Figure 8-102 dP First and Last Flow Cycle in Test CIBAP 11
Tests CIBAP20 and CIBAP21 were sequential addition tests performed with flow between []a,, (see Section 8.19, Figure 8-28 and Section 8.20, Figure 8-29). The resulting dP vs. flow
curves are shown in Figure 8-103 and Figure 8-104 along with the power curve fit that provides the
exponent used in Eq. 5.1.1 defining the relationship of the test data to the acceptance criterion as defined
in Section 5.0. For tests CIBAP17 through CIBAP21, and CIBAP23, the data was taken from the flow
sweeps after all debris had been added and the flow had stabilized. In these cases the data follows the
power law relationship between dP and flow rate very well. Moreover, for all of the tests, the debris bed
quickly reaches a stable resistance that does not change when the maximum and minimum flow values for
the flow sweeps is repeated. This is generally true for all tests in which flow sweeps were performed.
Revision 5 8-117
Revision 5 8-117
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-103 dP Versus Flow For Test CIBAP20
a,c
Figure 8-104 dP Versus Flow For Test CIBAP21
Test CIBAP25, CIBAP26, CIBAP30 through CIBAP34, CIBAP36 and CIBAP37 were concurrent
addition tests performed with flow rates between [ ]a.c (see Section 8.24, Figure 8-41
and Section 8.25 Figure 8-42) and between [ ]ac (see Section 8.29-Section 8.33,
Section 8.35 and Section 8.36, Figure 8-56, Figure 8-64, Figure 8-65, Figure 8-66, Figure 8-67,
Figure 8-74, Figure 8-80). The resulting dP vs. flow curve for tests CIBAP 25, CIBAP26 and CIBAP30
are shown in Figure 8-105, Figure 8-106 and Figure 8-107 along with the power curve fit that provide the
exponents used in Eq. 5.1.1 defining the relationship of the test data to the acceptance criterion as defined
in Section 5.0. For tests CIBAP22, CIBAP24 through CIBAP34, CIBAP36 and CIBAP37, the data was
taken from the flow sweeps after all debris had been added and the flow had stabilized. In these cases the
data follows the power law relationship between dP and flow rate very well. The debris bed remains
8-118 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
stable once it is formed and pressure drops are repeated when the flow sweeps are repeated. Moreover,
the exponent of the power law describing the data for the concurrent debris addition tests is similar to that
seen in the sequential debris addition tests.
a,c
Figure 8-105 dP Versus Flow For Test CIBAP25
a,c
Figure 8-106 dP Versus Flow For Test CIBAP26
Revision 5 X-1 19
Revision 5 8-119
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-107 dP Versus Flow For Test CIBAP30
8.39.2 Bed Stability During Flow Sweeps
As discussed above, the experimental data indicates that during the flow sweep operations the debris bed
quickly reaches a stable resistance that remains constant when the maximum and minimum flow sweep
value is repeated. For example, in Figure 8-108 the data from test CIBAP20 (Figure 8-103) is displayed.
The curve that fits the data collected during the []apc The coefficients for the two curves
are nearly the same value, indicating that the debris bed resistance does not change.
8-120 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-108 dP Versus Flow for Test CIBAP20
There is one test in which a small, but well defined, variation in the debris bed resistance was observed.
The dP versus flow rate data from test CIBAP 18 is shown in Figure 8-109.
As seen in Figure 8-109, the data collected during the first 3.4 hours.
]•,c For Test CIBAP 18, the exponent was then estimated [
]a,c
Revision 5 8-121
Revision 5 8-121
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-109 dP Versus Flow during the First and the Last Part of the Flow Sweeps in
Test CIBAP18
From the data discussed above, it is concluded that for the AP 1000 debris loads tested, the debris bed
collected at the bottom of the FA is stable. Specifically, the hydraulic characteristics of the bed were not
observed to change significantly as [
]a,c
8.39.3 Basis for the Developed Correlation
As discussed in previous sections, many of the AP1000 tests have been conducted with variable flow rates
where the flow was changed during the test as the dP increased to simulate the actual behavior of the
plant. The acceptability of the AP 1000 FA tests is verified by a criterion based on the LTCC sensitivity
Case #10 (Reference 3). This first part of the cold-leg acceptance criteria allows a maximum head-loss of
I ]a,c Moreover, to simulate the expected behavior of the AP 1000
in the post LOCA LTCC, the later tests were performed by concurrent additions of []apc and an additional cold-leg acceptance criteria was defined. The second part of the
cold-leg acceptance criteria applies to time [ ]a"c The second criterion is
based on LTCC sensitivity Case #3 and applies to times [ ]a•c This second criterion allows a
maximum head-loss of [ ]a,c
The use of both the criteria, as well as the correlation adopted, is discussed here.
8-122 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
As discussed previously, the later of the AP1000 tests were conducted with variable flow rates where the
flow was changed during the test. In order to compare the results against both the first and the second
criteria, the experimental results needed to be adjusted to a lower flow rate [ac
The data collected by the tests resulted in the development of the following equation which defines the
relationship between head-loss and the flow rate. This equation is based on the Darcy formula and the
exponent is determined by test results:ac
Eq 8.39.1
When the debris bed is formed and stable, the pressure drop behavior of the debris bed will vary
consistently with flow rate. In other words, [ ]a, This also means that
once the value of ]a,,c it is possible to evaluate the value of the
loss of pressure at any flow rate.
I I a,c
(Eq 8.39.2)
And then
I I a,c
(Eq 8.39.3)
where:a,c
Revision 5 8-123
Revision 5 8-123
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
The applicability of the former correlation is separately discussed and justified in the following for the
two acceptance criteria.
Applicability to the First Acceptance Criterion
To compare the test results against the first acceptance criterion, the following equation is used, deduced
on the basis of Eq. (8.39.3):
K(Eq.8.39.4)where:
a,c
Eq. (8.39.4) is deduced by Eq. (8.39.3) and makes use of the experimental exponents deduced by the flow
sweep at the end of the tests. Moreover, the stability of the debris bed is assumed. In order to compare
the results against the first acceptance criteria [ ]a,C the results
obtained by the AP1000 FA tests are adjusted by Eq. (8.39.4) to determine the dP at the acceptance
criteria flow rate.
Test CIBAP 34 was performed to investigate the nature of the flow/dP relationship throughout the test to
allow comparison of the bed behavior for a fully formed and stable debris bed as well as for. the initially
formed debris bed.
Flow sweeps were performed throughout the duration of Test CIBAP 34 and the experimental results
confirm that the dP and the flow are related by a power law relationship as shown in Eq 8.39.1 even in the
case of a debris bed not yet fully formed. In Figure 8-110 the dP vs. Flow data from test CIBAP 34 are
reported. Each series of data is referred to a flow sweep, and a best-fit curve for each series is shown
also. As can be noted, Eq 8.39.1 provides an adequate fit to the data. However, both the coefficient "R"
as well as the exponent "b" will evolve as the debris bed evolves.
Figure 8-111 shows the estimated values for both the [ ]a" during test
CIBAP 34. The results show a [ ],,c to the final bed performance. They also
indicate that the bed saturates with chemicals and after a point does not change.
The results from test CIBAP 34 indicate that the relationship between the dP and the flow is not affected
by the decrease of flow rate during the test. Moreover, the exponent evaluated for the formed debris bed
by the flow sweep in test CIBAP 34 is representative of a debris bed at its maximum resistance]axc
8-124 Revision 5
8-124 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Figure 8-112 shows the dP measured during test CIBAP 34 and the dP adjusted at [ ]a,c The peakdP occurred between [ ]a,c The debris bedreached its maximum resistance
]a ̀ The reason the adjusted
dP is higher at this later time is that the flow rate in the test loop was reduced. Therefore, the adjustmentto [ ]"' did not reduce the flow as much. In test CIBAP 34 it can be noted that the dP adjusted to
[ remains constant when the flow rate is decreased from]a,, indicating that the debris bed was stable.
This Revision has been updated to consider the dP
]a,, of the test, in tests such as CIBAP 34. This results in using the highest adjusted dP to compareagainst the current acceptance criterion.
For the AP 1000 FA test results for which an experimental exponent was evaluated, it is possible to
discriminate among two general types of tests. The first type of test shows the adjusted dP reaching amaximum value and then remaining constant.. This indicates that the bed resistance reached its maximumand did not change during the remainder of the test. Tests CIBAP 20, CIBAP 21, CIBAP 22, CIBAP 23,
CIBAP 24, CIBAP 28, CIBAP 29, CIBAP 31, CIBAP 32, CIBAP 34, CIBAP 36 and CIBAP 37 belong tothis first type. Test CIBAP 11 can be included in this first type also because the resistance of the bed didnot change after the maximum was reached. The second type of tests shows a different behavior after thedebris bed reached its maximum resistance. The value of the resistance decreased before the end of the.test. Test CIBAP 08, CIBAP 09, CIBAP 10, CIBAP 18, CIBAP 19, CIBAP 25, CIBAP 26, CIBAP 27,
CIBAP 30 and CIBAP 33 belong to this second type. This decrease in the bed resistance can be caused
by a settlement of the bed (slow limited decrease of the resistance) as in the case of test CIBAP 27, or to a
breakthrough in the bed (fast drop in the bed resistance), as in the case of test CIBAP 30 (Figure 8-113).
For tests of the first type, the exponent evaluated at the end of the test by the flow sweep is representative
of a fully-formed bed at its maximum resistance. The use of such an exponent in the correlation is
suitable to properly adjust the measured dlP to [ ]a'c The use of such an exponent toevaluate the results of the tests of the second type could result in an underestimation of the adjusted d.
Test CIBAP 34 belongs to the first type of test. However, in the end of the sweep interval, a spike in the
flow resulted in a change of the bed resistance, suggesting that a breakthrough was caused by the spike.Thus, the last sweeps performed were not considered for the estimation of the exponent for the maximumresistance debris bed. However, the last part of the sweep offered sufficient data to estimate an exponent
for the reduced-resistance debris bed. This exponent was [ ]a,, the exponent relevant to themaximum resistance bed. On this basis, a sensitivity study was performed to evaluate the effect of a
reduced exponent on the dP [ ]a,, for the tests of the second type. This study considereda reduction of [ ]a, exponents.
Revision 5 8-125
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Table 8-3 shows the results of this study. The effect of the assumed reduction of the exponent on the
adjusted dDP is minimal. []a,c the difference in the results is negligible. Thus, for the tests of the
second type, the exponent evaluated by means of the flow sweep is suitable to be used in the correlation
to calculate the maximum resistance DP [ ]a,c
The impact of a 10% reduction on the exponent for the tests of the second type was also evaluated in the
AP 1000 FA debris test statistical study (Reference 19). The statistical results indicate that the probability
to exceed the acceptance criteria increases less [ ]aC for both the pressure drop and the natural log dP
when the exponent is reduced by 10%. The results [ ]ac
are summarized in the table below (Table 8-4). The impact of the possible uncertainties related to the
exponent is then limited on the overall probability to exceed the limits in the AP1000 core. This confirms
the choice to use the exponent evaluated by means of the flow sweep (stable bed exponent) for both first
type and second type of tests.
Table 8-3 Sensitivity Analysis on the Exponent for Type 2 Testsa,c
a,cTable 8-4 Probability to Exceed Acceptance Criteria, 95% UB Standard Deviation
I I
8-126 Revision 5
8-126 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Figure 8-110 Evolution of the dP-Flow Relationship during Test CIBAP 34
a,c
Figure 8-111 Evolution of the Exponent and Coefficient Characterizing the dp-Flow Relationship during
Test CIBAP 34
Revision 5 8-127
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Figure 8-112 Comparison Between the Measured DP and the DP Adjusted at ] "'c gpm for
Test CIBAP 34
Figure 8-113 Comparison Between the Measured DPAnd the DP adjusted at I ]ac gpm for Test
CIBAP 30
a,c
8-128 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004. WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Applicability to the Second Acceptance Criterion
The first acceptance criterion is based on the LTCC sensitivity case 10 (Reference 3), and its limit]a,c is related to the decay heat [ ]a c after the LOCA. The second criterion
is based on.the LTCC sensitivity Case #3 (Reference 3), which assumes the maximum blockage condition
in the core at the beginning of the recirculation. It is related to a higher level of the decay heat.
The second criterion is aimed to verify that during the recirculation, for any level of the decay heat
between the start of the recirculation phase (LTCC sensitivity case 3) and [ ]a,c (LTCC sensitivity
case 10), the core will be satisfactorily cooled, requiring that the loss of head through the core []a c Note that the concurrent debris addition FA tests were set up in
order to model the plant timing of debris addition after the start of recirculation. Thus, the test time can
be related to the plant time. In contrast, the sequential debris addition tests were set up to determine the
maximum DP value that would be achieved under the test condition, with no reference to the time at
which it would occur in the plant. For this reason the second acceptance criterion is not applicable to the
sequential debris addition tests, but only to the concurrent debris addition tests.
Concerning the applicability of equation (8.39.3) to the second acceptance criterion, the use of the stable
bed exponent would result in a greater underestimation of the adjusted DP. Looking at the results of test
CIBAP 34, the exponent at [ ]"a and the bed resistance is still
increasing. This suggests that a reduction [ ]a, should be applied at the stable bed exponent
to extrapolate the test results at higher flow rate [ ]ac For conservatism, a reduction [
pc on the exponent has been considered in this Revision when the second criterion is applied.
This reduction is based on the difference between the fully formed bed exponent and the lowest exponent
estimated in test CIBAP 34. For the second acceptance criterion eq. (8.39.3) then becomes:
2 (Eq. 8.39.5)
where: a,c
Revision 5 8-129
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Table 8-5 shows the test results and dP adjusted according to the second acceptance criterion.
Table 8-5 Test Results and dP Adjusted at 5.3 gpm for Comparison Against the Second AcceptanceCriterion
Conclusions
The evaluation of the results obtained by the AP 1000 FA tests to verify if they meet or not meet the first
acceptance criterion [ ]a,c is based on the following correlation:
a,c
Kla,c
The results from test CIBAP 34 indicates that the mathematical structure of the relationship between thedP and the flow is unaffected by the decrease of flow rate during the test.
To adjust the results obtained at higher flow rate [ ]ac the dP at the maximum debris bed
resistance is the proper input to use, instead of the measured peak dP, because it results in a higher
adjusted dP for those tests where the peak occurred before the maximum bed resistance was reached.
8-130 Revision 5
WCAP-17028-NP illAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
The exponent used in the correlation can affect the results
]a " However, the analysis performed showed that the proper exponent to be used has to be
related to the maximum resistance of the bed. For the type I tests, the resistance does not change after its
maximum is reached, and the debris bed remains stable. The exponent evaluated by the sweep at the end
of the test is representative of a stable debri's bed at its maximum resistance; thus it is the proper exponent
to use in the correlation to verify if the results meet the first acceptance criterion.
For type 2 tests, the resistance of the debris bed when the sweeps were performed was lower than the
maximum resistance. The exponent for these tests may be [ ]a,, less than the value it would have if
the bed resistance remained constant. The effect of this reduced exponent has been evaluated by a
sensitivity analysis and the results indicate that it can be neglected. Thus the exponent estimated by the
flow sweep at the end of the test will be used to extrapolate the results from higher flow rate
]ac
In Section 5.2, the use of an average value of the exponent for those tests where an experimental exponent
is not available has been discussed andjustiýfied. The experimental results suggest that the exponent
relevant to the fully formed bed is independent from the way the debris were added, as well as from the
way the flow rate was changed during the debris bed formation. In other words, the exponent is
independent from the way the bed was formed and its variability is small. Moreover, from the point of
view of the acceptability of the test results, i it should be noted that even with an extremely low exponent
]a " This is true even when the second acceptance criterion
]a,, is applied to the max dP measured ]a,, plant time in the concurrent debris addition
tests.
From a physical point of view, the relationship that relates the dP and the flow must be
]ac. This is consistent with the experimental evidence; even when the debris bed is not fully formed,a,,
the lowest value estimated for the exponent In spite of the possible uncertainty related to the
use of the stable bed exponent, as well as to' the use of an average exponent, the dP limits are never
exceeded for either criterion I or 2. Finally, it noted that both the acceptance criteria are based on
sensitivity cases performed in the LTCC analysis (on Case #10 per the first and Case #3 per the second)
and both are extremely conservative. The fact that the test results would meet the acceptance criterion
means that these tests are sufficient, in spite of the variability of the test results and the uncertainty
associated with the application of the developed correlations. Finally the AP1000 debris test statistical
study (Reference 19) calculates a core average dP at [ ]a c assuming a distribution of FA
resistances; this V is only 1.35 psi, which demonstrates a large margin to the current acceptance limit of
4.1 psi.
The second acceptance criterion applies only to the concurrent debris addition tests of
]a c The correlation for the second criterion is then:a c
Revision 5 8-131
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
The reduction of [ ]ac on the exponent is based on the experimental results obtained by test CIBAP 34.
8.40 INVALIDATED TESTS
CIBAP07 - This test was excluded due to a modification of the test loop that had been implemented prior
to CIBAP07. A bypass line was added after the pump to reduce the back pressure on the pump during
these relatively low flow rate tests. In this case, the valve in the bypass line was open too wide and when
the back pressure increased due to the increased head-loss, too much flow was diverted through the
bypass line and reduced the flow to the test column below allowable levels as set in the test plan. With
the rapid drop in flow rate below the allowable level set forth in the test plan, the data was deemed to be
unusable.
CIBAP12 - This test was excluded due to the addition of the constituent chemicals to the loop. The
procedure for testing chemicals in the loop requires that the chemicals be mixed outside the loop per
WCAP-16530-NP-A. For this test, the chemical constituents were added to the loop individually to see
the effect of in-situ mixing of the chemicals. When the chemical constituents were added to the mixing
tank there was a large fluctuation in the measured flow rate. This fluctuation was due to the rapid change
in conductivity when the chemicals were added to the loop. The magnetic flow meter can account for
changes in conductivity, but not if the changes occur too rapidly. Since the flow control system adjusts
the flow rate based on feedback from the flow meter, the flow control system was attempting to
compensate for the perceived spikes in the flow rate resulting in large fluctuations in the recorded data.
With the rapid fluctuations in the recorded data, the data was deemed to be unusable. Additionally, this
test would not have been allowed as part of the licensing basis since the chemicals were not created
outside of the loop per the accepted WCAP-16530-NP-A procedure.
CIBAP17 - This test is considered invalid because there were problems with how it was conducted and
with the loop configuration being different from the other AP1000 tests. Section 8.16 provides additional
discussion of the problems with this test.
CIBAP35 - This test is considered exploratory because it was a pre-test to determine the effects. of
down-flow (debris loads, test loop schematic, flow rate and pressure limitations) for test CIBAP38.
8-132 Revision S
8-132 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
9 CONCLUSIONS
9.1 TEST PROGRAM SUMMARY
This document presents the results of thirty-nine FA head-loss experiments that were performed to
quantify the head-loss across AP 1000 fuel assemblies during post-LOCA LTCC. The purpose of theseexperiments was to demonstrate that there is reasonable assurance that the AP 1000 can provide adequatecore cooling in the long-term following a LOCA.
The experiments, performed to assess the head-loss across the AP1000 fuel assemblies during LOCAs,
considered a variety of parameters that might occur in the AP 1000. In order to compare the different testsand to evaluate whether each test was successful, the LTCC analysis (Reference 3) was considered. Asdiscussed in Section 5.0, the LTCC analysis for a cold-leg break allows for a 4.1 psi head-loss at a flow ofI ]p ' None of the tests, CIBAPOI-CIBAP34, CIBAP36 and CIBAP37, performed for theAP1000 had flows that were this low during the debris addition phase. In fact, the more recent AP1000
tests are run with flow rates that are representative of no-debris dP conditions and end with flow rates that
are dependent on the magnitude of the core debris dP. [
]a,c
In order to determine whether a test meets the LTCC criteria, the maximum dP measured in each test isscaled, as described immediately below, based on both the flow that existed when the maximum dP
occurred and the minimum acceptance flow [ ]",c for a cold-leg break. This scaled flow provides asimple way to compare tests and to determine if the test met the acceptance criteria.
This scaling is conducted using the equation and parameters discussed in Section 5.0.
]aC Also note that the flow sweeps reduced the flow
rate to the acceptance criteria flow so that this data is directly applicable. Such data is also available fortests CIBAP08 through CIBAP 11 due to the use of oscillating flows during the tests. For Tests CIBAPOIthrough CIBAP06 and CIBAP13 through CIBAP16 an average exponent [ pc was used. Theseresults are shown in Table 9-1 and also in Figure 9-1. The data show considerable margin between thescaled dP and the current LTCC limit. The maximum scaled dP from the tests is [
]" In contrast, thesequential debris addition tests were set up to determine the maximum dP value that would be achieved
under the test conditions.
]ac
Revision 5 9-1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
For the concurrent debris addition tests that utilized flow reduction schemes, an additional limit wasconsidered based on sensitivity Case 3 in the LTCC analysis (Reference 3). The additional criterion
requires that the max dP measured during the test at a scaled flow of []a,c In all of the concurrent addition tests the flow rate was higher than [ ]a,c into
the test. The test results are compared to this additional acceptance criteria are shown in Table 9-2.
The reasoning behind the acceptance criteria of [
]a"c This acceptancecriterion can be applied to the concurrent debris addition FA tests.
Table 9-1 AP1000 Fuel Debris Tests Scaled Results acIL--4...
4 4 4 1- 1- 1-
4 4 4 + + 4
4 4 t 1- 1- 1-
A -L L I 4- .4- 4-
4 4 4 4 4 1-
9-2 Revision 5
9-2 Revision 5
WCAP-l17028-NPAPP-MY13-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Table 9-1 AP1000 Fuel Debris Tests Scaled Results(cont.)
Revision 5 9-3
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Table 9-2 Scaled Maximum dP at Flow Prior to 9 Hours for Concurrent Addition Testsa,c
4 4 4 +
+ t 1 -1-
4 4 4 +
4 4 1 f
4 + 4 +
4 4 1 -4-
4 4 -4-
4 4 1 -I-
a,;
Figure 9-1 AP1000 Fuel Debris Tests Scaled Results
9-4 Revision 5
9-4 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
II
]ac
9.1.1 Latent Fiber Length
The AP1000 by design is a low-fiber plant. No fiber is produced by the LOCA. All of the fiber availablefor transport is latent fiber and the amount of this fiber is carefully controlled. The limiting breaklocations are cold-leg or (DVI breaks that become flooded by the water in the containment. In suchLOCAs all of the fiber that can be transported into the RCS flows through the break. As a result, the fiberthat reaches the core will not have passed through a screen and will have characteristics of the originallatent fiber.
Several tests were performed to determine the fiber length that produces the maximum head-loss.Six tests were performed to make this determination. [
]a,c
Two additional tests (CIBAP 13 and CIBAP 14) were conducted to further evaluate
]a,c
Revision 5 9-5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Questions arose on effect of the pump of fiber length and on the fibers used in AP1000 testing.
]a,c
a,c
Figure 9-2 Fibers Photographed Near the End of Test CIBAPll
I
]a,c
9-6 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a.c
Figure 9-3 Resident Fibers Collected from Plant B Described in NUREG/CR 6877
]a,c
In these tests, as well as the other AP 1000 cold-leg break tests, most of the FA head-loss occurred
9.1.2 Chemical Addition Rate
The early AP 1000 tests showed that there was minimal, if any, head-loss after the addition of all of the
particles and fibers. However, when the chemicals were added
]a,c
Revision 5 9-7
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
For example, in some of the earlier tests (CIBAPO1 through CIBAP05),
]a~c
In subsequent tests (for example, tests CIBAP06 through CIBAP 11), the initial chemical addition was [
I]a,c
The second evolution of the chemical addition method was to make the addition
]a,c
The third method of chemical addition was to add the AIOOH chemical solution
]a,c This practice was started on test CIBAP2 1. This method ofintroduction did not produce clearly different pressure drops, but was retained for tests after CIBAP21since it was thought to be the most realistic.
In summary, [
]apc the addition of chemical surrogates to the AP1000
licensing basis debris loads induced an increase in head-loss across the FA, and this increase was alwayswithin acceptance limits.
Another phenomenon that was observed
ac
9.1.3 Debris Quantities
Most of the AP1000 FA testing used the maximum debris amounts. The maximum amounts of debris inthe tests varied slightly since this testing was used to establish some of the debris limits, especially for the
amount of fiber.
9-8 Revision 5
9-8 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Ultimately, a plant design limit of
ac
For a hot-leg break scenario, it was assumed that
pc
The maximum limits for particles and chemicals were developed from the AP1000 design characteristics
and not from the FA tests. It was assumed that
]a,c
The plant design limit for particulate is
transport into the RCS with ]a~C All of this particulate was assumed to
]a.c of particles used in CIBAP26 and CIBAP28
FA tests. For tests CIBAP27, CIBAP29 through CIBAP34, CIBAP36, CIBAP37 and CIBAP39 [
]ac It was observed that that the particulate to fiber ratio impacted head-
loss; therefore various conditions were tested. The [ ]a', particulate to fiber ratio proved to be most
limiting and was used through the rest of the tests. Test CIBAP28
]a,c
The maximum chemical production calculated for 30 days following a LOCA is [ ]a'
(Reference 5). All of this chemical is assumed to transport into the RCS. When scaled, this results in a
maximum of [ ]a c A1OOH used in the FA tests.
In addition to assuming the maximum amounts of particle, fiber, and chemical debris, consideration was
also given to lesser amounts of debris since less than 100% transport could occur in the plant.
Less fiber was not tested because increasing amounts of fiber have always resulted in higher head-losses
in AP 1000 FA testing. In addition, the []ac
Less chemical was also not tested because every test run
]a,c
Revision 5 9-9
Revision 5 9-9
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
9.1.4 Flow Variations
In the AP 1000 plant, the flow rates tend noi to be constant following a LOCA because the flows are
driven by a natural circulation process. As a result, as debris accumulates in the core region and thehead-loss increases, the core flow will slow down. The debris accumulation takes many hours because ofthe large containment water volume and low passive safety system flow rates.
In addition, at any point in time, the flow -also oscillates for a period of several minutes and with aminimum flow rate of about [ ]a,c This oscillation is seen in the LTCC analysis and
simulated in select AP1000 FA head-loss tests as discussed below.
Several FA head-loss tests were conducted where the flow rate was oscillated throughout the test. Thisincluded tests CIBAP08 through CIBAP 11. The best comparison of these tests with non-oscillating testsis between test CIBAP08 and CIBAP06. These tests were identical except that test CIBAP06 used a
constant flow rate of [ ]ac and test CIBAP08 used an oscillating flow rate between [
]a" Another difference between these tests is that in test CIBAP08 the initial chemical additionwas less [ ]ac This is not a significant difference since both tests had an initial head-losspeak that later decreased. In addition, test CIBAP08 had a lower peak head-loss [
]a,c The conclusion is that the oscillating flow characteristic of AP1OOO seems to reduce thehead-losses. It is thought that the oscillating flow benefits the head-losses because the variation in flowand head-loss tends to increase the tendency to form bed breakthroughs or "bore holes." The effect of
such breakthroughs is commonly seen as sudden decreases in head-loss during a test. Using oscillatingflows during the AP 1000 tests was discontinued because of the complexity of running the tests and for
concerns about wear on the flow control valve.
Later AP 1000 tests have been conducted using varying flow rates where the flow was initially high andthen was decreased during the test as the head-loss built up. This process simulates the natural circulation
interaction with the debris head-loss. Several different initial flows that represent different break
sizes/locations have been tested. The final flow was based on the LTCC analysis with the maximum'head-loss. Except for tests CIBAP29 and CIBAP30, this minimum flow was designed to be [ ]a•c
The latest LTCC analysis has shown that the minimum flow can be even [ ]a," and was
used for CIBAP31 through CIBAP34, CIBAP36 and CIBAP37. The actual minimum flow used duringthese tests was dependent on the actual head-loss seen in the test. For some tests the head-loss wasrelatively low and as a result the flow was not reduced to the minimum just as would happen in the plant.
Tests CIBAP 15 and CIBAP 16 provide a baseline for an evaluation of flow conditions since they were
conduced at similar debris loads, but at constant flows. Test CIBAP15 was run at a constant []a,' Test CIBAP 18 started at [ . ]a C but since
its head-loss was very low, the flow was only reduced to [ ]ac The maximum head-loss ofCIBAP 18 was much less than either of these two constant flow tests. However, some of the other varying
flow tests resulted in higher head-losses. It has not been concluded whether varying the flow increases or
decreases the head-loss. All of the subsequent AP 1000 FA tests have been conducted with varying flowssince that is how the plant will operate. The initial flow has been set at [ ]a,c since that flow seemsto result in higher head-losses that other initial flows. [
]"'• (comparing tests CIBAP20 and CIBAP23) for sequence debris addition. However, for
9~ 10 Revision 5
92_10 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
concurrent debris addition (comparing tests CIBAP22 and CIBAP24),]p,' but the initial head-loss trend was more severe.
Tests CIBAP35, CIBAP38 and CIBAP39 evaluated hot-leg flow conditions. Tests CIBAP35 and.
CIBAP38 were conducted using varying flow rates where the flow was initially high]aC Once test CIBAP35 reached
] Test CIBAP38 began at
]a"c Overall, the hot-leg flow tests with
down-flow rates of [ ]ac The hot-leg
flow tests with upward flow of [ ]aC (simulating boiling) did not have a impact on head-loss.
9.1.5 Debris Addition Sequence
The initial API 000 FA debris tests (CIBAPO0 through CIBAP21) were conducted using sequential debris
addition; all the particles were added, then all the fiber, and finally all of the chemicals. It was
determined that it could not be shown that the AP1000 would operate this way and it could not be shown
that this debris addition sequence would result in bounding head-loss. As a result it was decided to repeat
one of the sequential tests using a concurrent debris addition method where the particles, fibers and
chemicals were added at the same time in multiple batches.
The rate of debris additions
]ac is considered the minimum time since it
assumes all of the particles and fibers are transported into the RCS in the time it takes to pass
one containment water volume through the RCS and the core is assumed to trap 100% of this debris (none
of the particles or fibers leaks/passes through the fuel).
Test CIBAP22 was the first concurrent addition test and was a repeat of test CIBAP20 which was a
sequential test. Between these tests, the concurrent test had a head-loss that was [ ]ax As a
result, additional concurrent tests were performed. These tests included:
Thin bed effect - The particles and fibers were introduced in []a,, more batches. Even with this gradual addition of debris, there was no indication of a
thin bed effect.
Testing different initial flow rates [ ]a,c As discussed in Section 9.1.4, the flowrates in the concurrent debris addition tests were initiated at a higher flow rate and the flow was
decreased as the dP increased. The final flow was determined by how much the dP increased.
Both []a, were used as the initial flow rate. []ac but had a more rapid initial dP increase rate so it was considered
bounding (or at least comparable).
Adding the particles/fibers at a slower rate (CIBAP25). [ac
Revision 5 9-11
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Adding the chemicals at a 67% slower rate (CIBAP26).a,c
* Adding fewer particles.
ac
Repeat tests. The most limiting test observed (CIBAP27) was repeated five times. Test
CIBAP27 used
]a,C than test CIBAP27.
]a"C Therefore, even though there was significant variation
between these repeat tests, none of them had a higher dP than the original test and all had
considerable margin to the current acceptance limits.
9.1.6 Coolant Chemistry and Temperature
Tests before CIBAP36 were all conducted with a target temperature of]as These conditions are not representative of what would be
expected for a LOCA in an AP 1000. The coolant would contain a mixture of []a,, Pure water and a low test temperature were used in testing because these
conditions were thought to be [ ]ac To confirm this, tests
CIBAP36 and CIBAP37 were performed with []a,c CIBAP37 was a repeat of CIBAP36.
The following factors were considered in developing tests CIBAP36 and CIBAP37:
Boric acid in the passive core cooling system water would come from two sources. Some of the boric
acid would originate in the RCS coolant, where boric acid is added for a reactivity shim. Additional boric
acid is added after the LOCA to einsure that the core remains non-critical using the core make-up tanks,
the accumulators, and the IRWST.
ac
]a,c
Temperatures in the core will remain near 212'F for many days during the LTCC period. However, the
test loop materials of construction could be operated safely only to [ ]a, so this value was selected asthe test temperature.
9-12 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Tests CIBAP36 and CIBAP37 had []a"C The average maximum pressure drop for the elevated temperature tests
was [ ]ac which compares to an average maximum pressure drop of [ ]aC for room
temperature tests CIBAP27, CIBAP29, CIBAP30, CIBAP31, CIBAP32, CIBAP33 and CIBAP34. The
average maximum dP was reduced by a factor of [ ]a,c The maximum pressure drop data is plotted in
Figure 9-4.a,c
Figure 9-4 Comparison of Tests atWater Tests
]ac with Boric Acid and TSP to Room Temperature
There were multiple factors for the reduced pressure drop in tests CIBAP36 and CIBAP37. One major
factor would be the change in viscosity of the coolant between [ ]ac For flow through a
porous medium, the pressure drop should be proportional to the viscosity of the fluid according to Darcy's
Law (Eq. 9-1.)
K.A.AP
W.L(Eq. 9-1)
Where
QK
A
LAP
volumetric flow rate (ft3/s)
permeability (ft2)
area (ft2)dynamic viscosity (lbf-s/in 2)length of porous bed (ft)dP drop across bed (psid)
Revision 5 9-13
Revision 5 9-13
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
Since the flow was experimentally determined to vary as approximately the velocity to the [ ]a,
there was clearly an inertial component to the flow, and the pressure drop would be less influenced by thedrop in viscosity with increasing temperature.
The viscosity of water decreases by a factor of [ ]ac Exact datais not available for a boric acid/ TSP solution of the concentration tested here, but data obtained for a
2466 ppm boric acid/ 1% TSP solution showed that the viscosity compared to water increased by 8%.Thus, the ]a,c
Additional decreases in the head-loss may have been due to specific chemical interactions with the fiber.Trisodium phosphate is a known powerful alkaline cleaning agent, and it may have altered the surfaceproperties of the fiber making it more slippery and less likely to form a blockage. This scenario is
supported by the observation that]a,c in both CIBAP36 and CIBAP37.
a,c
9.1.7 Effect of Debris Addition with Different Break Scenarios (Hot-Leg vs. Cold-Leg)
In the AP1000, debris can transport into the RCS though the flooded hot-leg and possibly into the upper
parts of the core. In an actual hot-leg LOCA in an AP1000, the flow in the upper part of the core isexpected to oscillate over several minutes. When the down-flow in a low-power assembly becomes low,
the steam generation rises. The tests prior to CIBAP35 were all conducted simulating a cold-leg breakscenario and without simulating boiling. However, in response to an NRC RAI, hot-leg break scenarioswere conducted to prove that cold-leg break tests are more limiting even if debris entering the top of the
core would occur in a hot-leg break. These conditions were to be tested for an expected hot-leg breakLOCA in an AP1000.
In the event of a digital electrohydraulic hot-leg break, Westinghouse assumes the post-LOCAcontainment debris load would be equal to 180 pounds, consisting of 6.6 pounds of fiber, 173.4 pounds ofparticulates and 57 pounds of chemical precipitates. Westinghouse assumes that all the debris is
transported into the core through the outer ring. As shown in]a,c
The following factors were considered in developing tests CIBAP38 and CIBAP39.
CIBAP38: This purpose of this test was to investigate the debris behavior in the outer FAs whereflow could be downward and transport debris into the upper part of these FAs. The test alsoinvestigated the impact of changing the direction of flow from the downward to the upwarddirection representing steam with boiling present in the upward direction.
CIBAP39: The purpose of this test was to investigate the debris behavior in central FAs that willbe exposed to constant upward flow of water and steam.
9-14 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
CIBAP38 was conducted to represent the down-flow in a low-power assembly that produces steam and
results in a change in flow from the downward to upward direction. This flow reversal and its effect on a
debris bed were explored in test CIBAP38.
]ac
Test CIBAP39 was conducted solely to represent the hot-leg break condition representing the steam in the
upward flow direction and the local boiling phenomenon affecting the behavior of the debris plugging the
core. The air was injected at the same rate in test CIBAP38,
ac
Tests CIBAP38 and CIBAP39 had very low pressure drops, [
pac
II
]ac
Revision 5 9-15
Revision 5 9-15
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Figure 9-5 AP1000 FA Schematic
9.2 APPLICABILITY OF TESTING TO AP1000 DESIGN
The experiments performed for the 'Evaluation of Debris Loading Head-loss Tests for AP1000 Fuel
Assemblies During Loss of Coolant Accidents' used an FA design that for the purposes of this testing isconsistent with the FA design described in subsection 4.2.2.2 of the AP1000 DCD (Reference 2). Thespecific AP 1000 bottom nozzle design was used to ensure that the actual geometry of this component was
included in the AP1000 test. The other components, [
]a,c
The fibrous and particulate debris types and chemical effects used in the AP 1000 FA head-lossexperiments have been identified as those that would be expected in an operating AP 1000. The flow rates
(Section 7) and debris loads (Section 6) [la" as proposed for the AP1000. Based on the discussion provided in the noted
sections, the flow rates and scaled debris loads and flow rates used in the experiments are applicable tothe AP 1000.
9-16 Revision 5
9-16 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
The fibrous, particulate, and chemical effects debris used in the experiments were prepared per procedure
as discussed in Sections 6.1, 6.2, and 6.3 using the noted preparation procedures. The fibrous, particulate,
and chemical effects debris used in the experiments are applicable to the AP1000.
The experiments were performed with representative debris and chemical precipitates at flows that bound
the flows expected in the post-LOCAAP1000. As can be observed from the experimental data, including
graphs and photographs, the amount of debris that can be transported to the AP1000 fuel assemblies is
minimal and is not sufficient to form a debris bed capable of reducing flow into the core to less than the
minimum shown to provide adequate core cooling. This was shown to be true for the licensing basis
debris and chemical effects load. The resulting head-loss in all experiments is considered to be
insufficient to preclude the reasonable assurance of LTCC for the AP 1000.
Experiments were performed with prototypical solution chemistry (boric acid and TSP) and at an elevated
temperature. Before these experiments were performed, all tests used pure water and a low test
temperature-because these conditions were thought to be conservative relative to the actual reactor
conditions. The experiments performed with the reactor coolant chemicals (boric acid and TSP) at the
elevated temperature collected less debris resulting in a lower dP. These sensitivity tests proved that the
pure water and low temperature tests that were run throughout the test program are most limiting.
Experiments were performed with down-flow and up-flow with simulated boiling for a flooded hot-leg
break. These tests proved that the cold-leg tests are more limiting than the hot-leg tests. The debris
entering the core inlet and forming a bed at the bottom nozzle for a cold-leg break without simulated
boiling proved to have a greater dP compared to both the up-flow and down-flow simulating the hot-leg
break.
Considering the test apparatus, the debris loads, the flow rates, and the preparation of materials, the
resulting data from this test program is directly applicable to the AP1000 design.
Revision 5 9-17
Revision 5 9-17
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
10 SUMMARY
Thirty-nine FA head-loss experiments were conducted for the AP 1000 design as part of the response to
GSI-191, "Assessment of Debris Accumulation on PWR Sump Performance." These FAhead-loss
experiments were performed for the AP1000 to quantify the head-loss across the FAs considering fibrous
and particulate debris and containment chemical effects applicable to the AP 1000.
The experiments performed used an FA design that, for the purposes of the testing, is consistent with the
FA design described in subsection 4.2.2.2 of the AP 1000 DCD (Reference 2). The flow rates and fibrous
and particulate debris loading conditions were selected conservatively so that they bound those expected
following a postulated LOCA for the AP 1000. The FA, debris loads, and flow rates are directly
applicable to the AP 1000 as described in Section 4.0 of this report.
The thirty-nine FA head-loss experiments that were performed for the API1000 design investigated a
spectrum of fibrous and particulate debris loads and chemical effects. The results from thirty-five' of
these experiments demonstrate the ability of the AP1000 to provide reasonable assurance of LTCC under
the fibrous and particulate debris loading and chemical effects conditions expected for the AP1000
following a postulated LOCA.
The AP 1000 design]apc and,
requires good house keeping practices. The AP 1000 design is engineered to reduce the potential for
head-loss during long-term cooling operation. These experiments show that the design basis AP 1000
fibrous and particulate debris, and chemical effects, (that is, the maximum amount of debris that could
exist) does not induce a head-loss through the FA that would reduce flow into the core to less than the
minimum shown to provide adequate LTCC and the maintaining of a coolable core geometry following a
LOCA.
1. Tests 7, 12, 17 and 35 were invalidated. See Section 8.40
Revision 5 10-1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
11 REFERENCES
1. Generic Safety Issue, GSI- 191, "Assessment of Debris Accumulation on PWR Sump
Performance," 1998.
2. APP-GW-GL-700, Revision 17, "AP 1000 Design Control Document," 2008.
3. APP-PXS-GLR-001, Revision 4, "Impact on AP1000 Post-LOCA Long-Term Cooling of
Postulated Containment Sump Debris," February 2010.
4. NEI 04-07 PRESSURIZED WATER REACTOR SUMP PERFORMANCE EVALUATION
METHODOLOGY Revision 0 December 2004 Volume 2 - Safety Evaluation by the Office of
Nuclear Reactor Regulation Related to NRC Generic Letter 2004-02, Revision 0,
December 2004.
5. APP-GW-GLR-079, Revision 7, "AP1000 Verification of Water Sources for Long-Term
Recirculation Cooling Following a LOCA," February 2010.
6. Letter from H. K. Nieh (NRC) to G. Bischoff (PWROG), "Final Safety Evaluation for Pressurized
Water Reactor Owners Group (PWROG) Topical Report (TR) WCAP-16530-NP, 'Evaluation of
Post-Accident Chemical Effects in Containment Sump Fluids to Support GSI-191,'
(TAC No. MD1119)," December 2007.
7. STD-MCE-09-8, Revision 0, "Summary of the Results from the AP1000 Core Inlet Blockage
Tests," February 2009.
8. STD-MCE-09-47, Revision 0, "Summary of the Results from the AP 1000 Core Inlet BlockageTests: CIBAP05 to CIBAP14," June 2009.
9. APP-FAO0-T1P-001, Revision 1, "Test Plan For AP1000 Debris Loading Head-loss Across FA,"
June 2009.
10. Revised Guidance for Review of Final Licensee Responses to Generic Letter 2004-02, "Potential
Impact of Debris Blockage on Emergency Recirculation During Design Basis Accidents at
Pressurized Water Reactors," March 2008. [ML080230234]
11. WCAP-16530-NP-A, "Evaluation of Post-Accident Chemical Effects in Containment Sump
Fluids to Support GSI- 19 1," March 2008.
12. NUREG/CR-6877, "Characterization and Head-Loss Testing of Latent Debris fromPressurized-Water-Reactor Containment Buildings," July 2005.
13. STD-MCE-09-74, Revision 0, "Summary of the Results from the AP 1000 Core Inlet Blockage
Tests: CIBAP15 and CIBAP16," July 2009.
Revision 5 11-1
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
14. STD-MCE-09-139, Revision 0, "Summary of the Results from the AP1000 Core Inlet Blockage
Tests: CIBAP17 Through CIBAP30," November 2009.
15. STD-MCE- 10-19, Revision 0, "Summary of the Results from the AP 1000 Core Inlet Blockage
Tests: CIBAP31 Through CIBAP39," February 2010.
16. XX1 CRC Handbook of Chemistry and Physics, 5 5th Edition, Robert Weast, Ed. (CRC Press,
Cleveland, Ohio) 1974, p F-49.
17. G. Zigler, J. Brideau, D. V. Rao, C. Shaffer, F. Souto, W. Thomas, NUREG/CR-6224, "Parametric
Study of the Potential for BWR ECCS Strainer Blockage Due to LOCA Generated Debris" Final
Report, October 1995
18. Appendix VII, "Characterization of Pressurized-Water-Reactor Latent Debris", part of GSI- 191
SE, Revision 0 'Safety Evaluation of NEI Guidance on PWR Sump Performance", Nuclear
Regulatory Commission (http :/www.nrc. ,ov/reactor-s/operating,/ops-expefiefice/
pwr-stump-perfornmanceireg-guidance-fi les/m1043280017-appvii.pd.)
19. APP-GW-GLR-092, Rev. 0, "Statistical Evaluation ofAP 1000 Fuel Assembly Debris-Loading
Head-Loss Tests," February 2009.
20. Excel File: Air Flow Rate Calculation. February 2010. (Note: This document is electronically
attached to this calculation note as
void-fraction-quality TLS_.xls_634027217282889675_WCAP-1 7028-P)
11-2 Revision 5
I11-2 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 .AP 1000
APPENDIX AAPP-FAO1-T1P-001 REVISION 0: TEST PLAN FOR AP1000 DEBRIS
LOADING HEAD-LOSS ACROSS FUEL ASSEMBLY
This Appendix is proprietary in its entirety.
Revision 5 A-1
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
A-2 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3APiO00
a,c
Revision 5 A-3
WCAP- 1 7028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
A-4 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3. APIO00
a,c
Revision 5 A-5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
A-6 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3APIO00
a,c
Revision 5 A-7
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
A-8 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 A-9
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3API1000
a,c
A-10 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 A-11
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3API 000
a,c
A- 12 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
Revision 5 A-13
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
A- 14 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 A-15
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
A-16 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3API 000
a,c
Revision 5 A- 17
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
A-18 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
Revision 5 A- 19
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
A-20 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
APPENDIX BAPP-FA01-TIP-001 REVISION 1: TEST PLAN FOR AP1000 DEBRIS
LOADING HEAD-LOSS ACROSS FUEL ASSEMBLY
This Appendix is proprietary in its entirety.
Revision 5 B-1
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
B-2 Revision 5
B-2 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3API 000
a,c
Revision 5 B-3
Revision 5 B-3
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
ax.
B-4 Revision 5
B-4 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
Revision 5 B-S
Revision 5 B-5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
B-6 Revision '
B-6 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 B-7
Revision 5 B-7
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
aIc,
B-8 Revision 5
B-8 Revision 5
WCAP-17028-NP WESTINGHOUSE NON-PROPRIETARY CLASS 3
APP-MY03-T2C-004 AP 1000
a,c
Revision 5 B-9
Revision 5 B-9
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
B- 10 Revision 5
B-10 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 B-il
Revision 5 B-1II
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
B- 12 Revision 5
B3-12 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a ,c
Revision 5 B- 13
Revision 5 B-13
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
B-14 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
Revision 5 B- 15
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000.
a,c
B- 16 Revision 5
B-16 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3APIO00
a,c
Revision 5 B- 17
Revision 5 B- 17
WCAP- 1 7028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
B-18 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
Appendix CTEST PROCEDURES FOR AP1000 DEBRIS
LOADING HEAD LOSS ACROSS FUEL ASSEMBLY
C.1 TEST PLAN FOR LOOP TEST CIBAP01
STD-MCE-08-79
Revision 5 C-1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-2 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-3
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-4 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-6 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-7
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-8 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-9
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-10 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
I
Revision 5 C-1I1
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-12 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-13
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c•
C-14 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-15
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIOOO
a,c
C-16 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-17
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.2 TEST PLAN FOR LOOP TEST CIBAP02
STD-MCE-08-80
0-IR Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
I
Revision 5 C- 19
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c.
C-20 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-21
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-22 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
Revision 5 C-23
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-24 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-25
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-26 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-27
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-28 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
I
Revision 5 C-29
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-30 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-31
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
ac
C-32 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-33
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-34 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-35
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.3 TEST PLAN FOR LOOP TEST CIBAP03
STD-MCE-08-81
C-36 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-37
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-38 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-39
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-40 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-41
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-42 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-43
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-44 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-45
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-46 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-47
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-48 Revision 5
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-49
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-50 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-51
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-52 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-53
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-54 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.4 TEST PLAN FOR LOOP TEST CIBAP04
STD-MCE-08-82
Revision 5 C-55
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-56 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-57
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-59 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1600
a,c
Revision 5 C-59
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 , AP1000
a,c
I
C-60 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a~cI
Revision 5 C-61
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-62 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,C
Revision 5 C-63
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
I
C-64 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-65
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-66 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-67
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-69 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-69
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-70 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-71
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-72 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.5 TEST PLAN FOR LOOP TEST CIBAP05
STD-MCE-08-85
Revision 5 C-73
WCAP- 17028-NPAPP-.MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-74 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-75
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-76 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-77
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-78 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-79
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-80 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-81
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-82 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-83
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-84 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-85
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-86 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-87
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-88 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.6 TEST PLAN FOR LOOP TEST CIBAP06
STD-MCE-09-18
Revision 5 C-89
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
C-90 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-91
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-92 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-93
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-94 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-95
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-96 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-97
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-98 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-99
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C--100 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-101
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C- 102 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-103
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-104 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-105
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
AP 1000
C.7 TEST PLAN FOR LOOP TEST CIBAP08
STD-MCE-09-28
C-106 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-107
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a~c
C-108 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-109
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-1 10 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-1l1
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-1 12 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-113
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-1 14 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 .AP1000
a,c
Revision 5 C-1 15
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C- 116 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-1 17
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-1 18 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-1 19
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-120 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
Revision 5 C-121
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-122 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
C.8 TEST PLAN FOR LOOP TEST CIBAP09
STD-MCE-09-34
Revision 5 C-123
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-124 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-125
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-126 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-127
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-128 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-129
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-130 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-131
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-132 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-133
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-134 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-135
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-136 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
Revision 5 C-137
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-138 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-139
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
C.9 TEST PLAN FOR LOOP TEST CIBAP10
STD-MCE-09-35 Revision 1
C-140 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C- 141
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-142 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C- 143
WCAP- 17028-NPAPP-MY03-T2C-004. WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-144 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C- 145
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-146 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
Revision 5 C- 147
WCAP-1 7028-NPAPP-MY03-T2C-004. WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-1'48 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C- 149
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-150 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-151
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-152 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-153
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-154 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-155
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
C- 156 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-157
WCAP- 17028-NPA PP-MVO(¥-T9C-flf04 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APli 000APP-MY03-T2C-004 AP 1000
C.10 TEST PLAN FOR LOOP TEST CIBAPlI
STD-MCE-09-39
C1 58 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-159
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-160 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-161
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-162 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-163
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C- 164 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-165
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-166 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C- 167
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-168 Revision 5
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C- 169
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-'170 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-171
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-172 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-173
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
C-174 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.11 TEST PLAN FOR LOOP TEST CIBAP13
STD-MCE-09-42
Revision 5 C-175
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-176 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-177
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-178 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-179
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-190 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-181
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-182 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-183
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-184 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-185
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-186 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
I
Revision 5 C-187
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
c-1•8 Revision 5
WCAP- I 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-189
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-190 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C- 191
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C- 192 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
C.12 TEST PLAN FOR LOOP TEST CIBAP14
STD-MCE-09-45
Revision 5 C-193
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-194 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-195
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-196 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-197
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-198 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-199
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-200 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-201
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
C-202 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-203
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-204 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-205
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-206 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-207
WCAP-17028-NPAýPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-208 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-209
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
C.13 TEST PLAN FOR LOOP TEST CIBAP15
STD-MCE-09-61
C-210 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-211
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-212 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 . . AP1000
a,c
Revision 5 C-213
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-214 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-215
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-216 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-217
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-218 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-219
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-220 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-221
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-222 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS.3 AP 1000
a,c
Revision 5 C-223
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-224 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-225
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-226 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-227
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-228 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOU 1SF NON-PROPRIETARY CLASS 3 AP1000
C.14 TEST PLAN FOR LOOP TEST CIBAP16
STD-MCE-09-71
Revision 5 C-229
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-230 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
Revision 5 C-231
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-232 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-233
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-234 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-235
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-236 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-237
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-238 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-239
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-240 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-241
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-242 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 . API 000
a,c
Revision 5 C-243
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-244 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-245
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-246 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,C
Revision 5 C-247
WCAP-17028-NPAPP-MY03-T2C-004 'WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
C.15 TEST PLAN FOR LOOP TEST CIBAP17
STD-MCE-09-101
C-249 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-249
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-250 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-251
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
c-252 Revision 5
WCAP-.17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-253
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-254 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-255
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-256 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-257
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-259 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,C
Revision 5 C-259
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-260 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-261
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-262 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-263
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-264 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-265
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
C-2'66 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-267
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-268 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-269
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-270 Revision 5
WCAP- 17028-NPA PP.E/wO•Tg(r-OnA WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000APP-MY03-T2C-O()4
C.16 TEST PLAN FOR LOOP TEST CIBAP18
STD-MCE-09-102
Revision 5 C-271
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-272 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-273
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-274 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 .C-275
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-276 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-277
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-278 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-279
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-280 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-281
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-282 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-283
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-284 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-285
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-286 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-287
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-2R8 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-289
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-290 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-291
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-292 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.17 TEST PLAN FOR LOOP TEST CIBAP19
STD-MCE-09-103
Revision 5 C-293
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-294 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-295
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-296 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-297
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-298 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a~c
Revision 5 C-299
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-300 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-301
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-302 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
Revision 5 C-303
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
I
C-304 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,C
Revision 5 C-305
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-306 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-307
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-308 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
Revision 5 C-309
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-310 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
ac
Revision 5 C-311
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-311 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-313
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-314 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000,
a,c
Revision 5 C-315
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.18 TEST PLAN FOR LOOP TEST CIBAP20
STD-MCE-09-107
C-316 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-317
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-318 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-319
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-320 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-321
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-322 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-323
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-324 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-325
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-326 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-327
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-328 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 -AP1000
a,cI
Revision 5 C-329
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-330 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-331
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-332 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-333
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-334 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-335
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-116 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-337
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-338 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
C.19 TEST PLAN FOR LOOP TEST CIBAP21
STD-MCE-09-108
Revision 5 C-339
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-340 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-341
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Cý-342 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-343
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-344 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
I
Revision 5 C-345
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-346 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-347
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-349 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP IQ00
a,c
Revision 5 C-349
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-350 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-351
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-352 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-353
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-354 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-355
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-356 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-357
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c, I
C-358 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-359
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-360 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
Revision 5 C-361
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.20 TEST PLAN FOR LOOP TEST CIBAP22
STD-MCE-09-109
* C-362 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-363
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-364 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-365
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-366 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
Revision 5 C-367
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-368 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 . API000
a,c
Revision 5 .C-369
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-370 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-371
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-372 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-373
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-174 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-375
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-376 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a~c
Revision 5 C-377
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-378 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-379
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-380 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-381
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-382 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-383
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-384 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-385
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
C.21 TEST PLAN FOR LOOP TEST CIBAP23
STD-MCE-09-113
C-386 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-387
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-388 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-389
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-390 Revision -5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-391
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
•C-392 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-393
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-394 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-395
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-396 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 -C-397
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
I
C-398 Revision 5
WCAP- 1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-399
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-400 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-401
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-402 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
I
Revision 5 C-403
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-404 Revision 5
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-405
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-406 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
C.22 TEST PLAN FOR LOOP TEST CIBAP24
STD-MCE-09-115
Revision 5 C-407
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-408 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-409
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-41 0 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-411
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-4129 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-413
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-414 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-415
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-416 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-417
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a~c
C-418 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-419
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-420 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-421
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-422 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-423
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-424 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-425
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-426 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-427
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-428 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 -AP1000
C.23 TEST PLAN FOR LOOP TEST CIBAP25
STD-MCE-09-116 Revision I
Revision 5 C-429
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-430 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-431
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-432 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-433
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-434 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-435
WCAP- 17028-NP.APP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-436 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,cI
Revision 5 C-437
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-438 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-439
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-440 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-441
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-442 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-443
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-444 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5C-445
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-446 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-447
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-448 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-449
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-450 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-451
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
C.24 TEST PLAN FOR LOOP TEST CIBAP26
STD-MCE-09-123
C-452 Revision 5
WCAP- 1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-453
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-454 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-455
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-456 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-457
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-45'8 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
Revision 5 C-459
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-460 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-461
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-462 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-463
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-464 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-465
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-466 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-467
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-468 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-469
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-470 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac .
Revision 5 C-471
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-472 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-473
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-474 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-475
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APl~flflf
AP 1000
C.25 TEST PLAN FOR LOOP TEST CIBAP27
STD-MCE-09-125
C-476 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-477
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-478 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-479
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-480 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-481
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-482 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-483
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-484 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-485
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-486 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-487
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-488 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-489
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-490 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-491
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-492 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 ý,AP1000
a,c
Revision 5 C-493
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-494 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-495
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-496 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-497
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-498 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-499
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.26 TEST PLAN FOR LOOP TEST CIBAP28
STD-MCE-09-132
C-500 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
axC
Revision 5 C-501
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-502 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-503
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-504 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-505
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-506 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-507
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c7
Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-509
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-510 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-511
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-512 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-513
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-514 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-515
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-516 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 'AP 1000
a,c
Revision 5 C-517
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-519
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-520 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-521
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-522 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-523
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-524 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGCHOT ISE NON-PROPRIETARY CLASS 3 AP 1000
C.27 TEST PLAN FOR LOOP TEST CIBAP29
STD-MCE-09-133 Revision
Revision 5 C-525
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-526 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-527
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-528 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-529
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-530 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-531
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-532 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-533
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-534 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-535
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-536 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-537
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-538 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-539
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-540 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-541
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-542 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-543
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-544 Revision 5
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-545
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-546 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-547
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AL i lflf
AP 1000
C.28 TEST PLAN FOR LOOP TEST CIBAP30
STD-MCE-09-135
C-548 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-549
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-5-50 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-551
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-552 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-553
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-554 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-555
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-556 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-557
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-558 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-559
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-560 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-561
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-562 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-563
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-564 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-565
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-566 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 .C-567
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-568 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-569
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-570 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WFSTINGHOI ISE NON-PROPRIFTARY CLASS 3 AP1000
C.29 TEST PLAN FOR LOOP TEST CIBAP31
STD-MCE-10-2
Revision 5 C-571
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-572 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-573
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-574 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-575
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-576 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-577
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-578 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-579
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-580 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-581
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-582 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-583
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-584 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-585
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-586 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-587
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-589
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-590 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-591
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-592 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-593
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
ac
C-594 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.30 TEST PLAN FOR LOOP TEST CIBAP32
STD-MCE-10-3
Revision 5 C-595
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-596 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-597
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
C-598 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-599
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-600 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-601
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-602 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-603
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-604 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-605
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-606 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
1'
Revision 5 C-607
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-608 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP.1 000
a,c
Revision 5 C-609
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-610 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-611
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-612 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-613
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-614 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-615
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-61"6 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-617
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-618 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.31 TEST PLAN FOR LOOP TEST CIBAP33
STD-MCE-10-4
Revision 5 C-619
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-620 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-621
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-622 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 000
a,c
Revision 5 C-623
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API1000
a,c
C-624 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-625
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-626 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-627
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-628 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-629
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
ac
C-630 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-631
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-612 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-633
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-634 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-635
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-636 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-637
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-638 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-639
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-640 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-641
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-642 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUJSE NON-PROPRIETARY CLASS 3 AP 1000
C.32 TEST PLAN FOR LOOP TEST CIBAP34
STD-MCE-10-5
Revision 5 C-643
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-644 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-645
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-646 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-647
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-648 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-649
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
I
C-650 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-651
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-652 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-653
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-654 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-655
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-;656 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-657
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-658 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-659
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-660 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-661
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-662 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-663
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-664 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-665
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-666 Revision 5
WCAP- 17028-NPAPP-MYO3-T2C-004 WRSTINGH-TOIJ SF NON-PROPRIFTARY CTAqq I APIOOO
AP 1000
C.33 TEST PLAN FOR LOOP TEST CIBAP35
STD-MCE-10-7
Revision 5 C-667
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-668 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-669
WCAP-17028-NPAPP-MYO3-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS'3 AP1000
a,c
C-670 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
I
Revision 5 C-671
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-672 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-673
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
0-674 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-675
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-676 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-677
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-67R Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-679
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-680 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-681
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-682 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-683
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-684 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
I
Revision 5 C-685
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-686 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.34 TEST PLAN FOR LOOP TEST CIBAP36
STD-MCE-10-10
Revision 5 C-687
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-688' Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-689
WCAP- 17028-NPAPP-MY03-T2C-004- WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-690 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-691
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-692 Revision 5
WCAP-17028-NP.APP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-693
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
C-694 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-695
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-696 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-697
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-698 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
Revision 5 C-699
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-700 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-701
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-702 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
aC
Revision 5. Cr703
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-704 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-705
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-706 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-707
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-708 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-709
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-710 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1O000
C.35 TEST PLAN FOR LOOP TEST CIBAP37
STD-MCE-10-11
Revision 5 C-711
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-712 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-713
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-714 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-715
WCAP- 17028-NPAPP-MY,3-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-71'6 Revision 5-
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-717
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-71 9 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-719
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-720 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-721
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-722 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-723
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-724 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-725
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-'726 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API 000
a,c
Revision 5 C-727
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-728 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-729
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-730 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-731
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-732 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
Revision 5 C-733
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-734 Revision 5
WCAP- 17028-NPAPP-MYO3-T2C-004 WFSTINGHOI JSE. NON-PROPRIETARY CLASS 3 AP1000
C.36 TEST PLAN FOR LOOP TEST CIBAP38
STD-MCE-10-13 Revision 1
Revision 5 C-735
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-736 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-:737
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
a,c
C-738 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-739
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-740 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-741
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-742 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-743
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-744 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-745
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-746 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-747
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-748 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
ac
Revision 5 C-749
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-750 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
Revision 5 C-751
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
ac
C-752 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
Revision 5 C-753
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-754 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-755
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-756 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
C.37 TEST PLAN FOR LOOP TEST CIBAP39
STD-MCE-10-15
Revision 5 C-757
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-758 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-759
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-760 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-761
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-762 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-763
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
a,c
C-764 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 APIO00
ac
Revision 5 C-765
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-766 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-767
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-768 Revision 5
WCAP-1 7028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-769
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-770 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-771
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-772 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-773
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a,c
C-774 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
Revision 5 C-775
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
a,c
C-776 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP 1000
APPENDIX DDEBRIS PREPARATION
This Appendix is proprietary in its entirety.
Revision 5 D- 1
Revision 5 D-1
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
D-2 Revision 5
D-2 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 D-3
Revision 5 D-3
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
D-4 Revision 5
D-4 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
Revision 5 V-5
Revision 5 D-5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,x
D-6 Revision 5
D-6 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 D-7
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
D-8 Revision 5
D-8 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
Revision 5 D-9
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
D- 10 Revision S
D-10 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 D-.1 1
Revision 5 D-1II
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
D- 12 Revision 5
D-12 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
Revision 5 D-13
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
D- 14 Revision 5
D- 14 Revision 5
WCAP-17028-NP WESTINGHOUSE NON-PROPRIETARY CLASS 3APP-MY03-T2C-004 AP 1000
a,c
Revision 5 v-I ~
Revision 5 D-15
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
D- 16 Revision 5
D- 16 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 API000
a~c
Revision 5 D-17
WCAP- 17028-NPAPP-MY03-T2C-004 WESTINGHOUSE NON-PROPRIETARY CLASS 3 AP1000
APPENDIX ETEST FACILITY OVERVIEW
This Appendix is proprietary in its entirety.
Revision 5 E-1
WCAP-17028-NP WESTINGHOUSE NON-PROPRIETARY CLASS 3APP-MY03-T2C-004 AP1000
a,c
E-2 Revision ~
E-2 Revision5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
Revision 5 E-3
Revision 5 E-3
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
E-4 Revision 5
E-4 Revision 5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3API000
a,c
Revision 5 E-5
Revision 5 E-5
WCAP-17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP1000
a,c
E-6 Revision 5
E-6 Revision 5
WCAP- 17028-NPAPP-MY03-T2C-004
WESTINGHOUSE NON-PROPRIETARY CLASS 3AP 1000
a,c
71
Revision 5 E-7
Revision 5 E-7
Recommended