Welcome to The Alpha Group Presentation by Ozcan Akbaba...

Preview:

Citation preview

Welcome to The Alpha Group

Presentation

by Ozcan Akbaba/ATTR/21/01/15

Total Power Solutions™ for:

• Communications Networks

• Traffic & Transportation

• Security & Public Safety

• Industrial & Utilities

• Renewable Energy

• Medical & OEM

• Smart Grid

ME Referances

AC Power Solutions

INDOOR 1P/3P Stand Alone UPSs

Modular UPSs

1P/3P STS

OUTDOOR

1P Rugged UPSs

CONTINUITY 1/3/6/10KVA

• True Online operation

• Zero transfer time in the event of a power disruption

• Models from 1 kVA up to 10 kVA

• High output PF 0.8 up to 3 kVA, 0.9 at 6 and 10kVA model

• Ideal for mission-critical applications: servers, voice and data networks

• Fully digitized microprocessor controlled

• Power factor correction

• SNMP internal slot included for web agent

• Extended battery connector included

• USB/RS232 interface

• Tower/Rackmount convertible design

• Up to 4 units in parallel (6 and 10kVA)

Example of an Outdoor Power System Enclosure

Battery heater mat

Gel batteries Outdoor AC UPS

(-40C to +74C)

Mounting bracket

Battery Charge Management System Transfer switch

X33 HE/HIP UPS / 10-1000KVA • Three phase input, three phase output

• True Online operation, IGBT rectifier technology

• Transformerless Technology

• High Efficiency up to 96.5% in online mode

• Output Power Factor 0.9

• THDI < 3%

• Zero transfer time

• Ideal for mission-critical applications

• Models available from 10kVA to 120kVA

• Fully digitized microprocessor controlled

• Power factor correction 0.99

• SNMP internal slot included for web agent

• Installation in parallel mode up to 8 units

Tri Power X33 HE uses online double conversion (VFI) technology where the load is always powered by the inverter ensuring a

filtered and stabilized sinusoidal voltage manufactured with the state of the art IGBT rectifier technology. Offering high efficiency

values up to 96.5% even in part load situations saves money on electricity bills protecting at the same time our enviroment with less

CO2 consumption. Light weight and small footprint allows easy, space saving and low cost installation. The 0.9 output power factor

provides up to 15% more active power than a traditional UPS and more load expansion. TRI X33 HE UPS systems are ideal for the

protection of critical information and telecommunications networks which can not run the risk of being powered from a poor quality

electrical supply.

8/62

Modular INDOOR/ HP SERIES 10-160

Flexibility

Power Sharing

N+X Redundancy

Power and Autonomy Scalability

Easy Management, Service and Maintenance

Modular Architecture :

Thanks to the

innovative

architecture, the Tri

Power X33 Mod

can adapt it self to

any kind of

electrical

connection.

Flexibility

Thanks to the innovative

architecture, the Tri Power

X33 Mod can adapt it self

to any kind of electrical

connection.

AMPS80 Alpha Modular Power System 80HP

High performance AC or hybrid AC/DC backup power system

99.999% reliability for mission critical indoor applications

48VDC BUS for Telecom

AMPS80 utilizes hot swappable 2.5k VA/ 2.0k W inverter

modules & optional 2/4kW rectifier modules

Ultimate flexibility, scalability and low MTTR

Intelligent system controller with integrated SNMP for local and

remote management of AC & DC power modules, batteries, and

other peripherals such as Battery Management Modules

15 year Design Life, >200,000 hours of MTBF and 98/94%

Efficiency mean low TCO

Small footprint system – up to 75kVA/ 60kW in a single 19” wide

box bay rack

frees up valuable rack space

AMPS80

AMPS80 Features & Benefits contd. 5. Integrated, Intelligent Controller with SNMP/ Ethernet

o Monitor/ manage both AC & DC power modules & peripherals locally

and remotely (via web pages)

o Lower training/ personnel costs

o Easy to use graphic LCD display

o CANBus protocol for highly reliable communication

One ‘master brain’ to manage AC & DC power systems & peripherals!

DC/ DC Converters

Integrated, Intelligent

Controller

Battery Monitoring AMPS Inverters/ UPS

Rectifiers

Highly Reliable Technology

• With TSI technology, each inverter module acts like an individual UPS and

can separate itself from the system, in case of failure

• Hence, TSI eliminates the need for Static Transfer Switch (STS), which, in

traditional double-conversion systems, is often the single point of failure

• Moreover, there is no transfer time when the module switches from AC to DC

mode

Traditional UPS Assembly

AMPS

Inverters

AMPS System with TSI Inverter Modules

DC Power Solutions

INDOOR Central Office DC PSs (400-10000A )

Small Office DC PSs(100-400A)

Cell Sites DC PSs(1-100A)

OUTDOOR Cell Sites DC PSs(1-100A)

DAS (1-50A)

Line Powering (1-5A)

FTTx Powering(1-3A)

48V / 360A

TT-18 kW

ERICSSON

BATTERY CABINET

48 V/1350 A

VODAFONE 1350 A /48V

VDF 2000A DC PS

VDF -2000/4000A

VDF-80KVA Single/Three ph-Inverter

Wataniya Telecom–Kuwait-6000A /48V

MOI-QATAR ( 2N ) 2X72KW

Installed base

Strong experience in cellular networks

> 250.000 BTS installed

Cordex CXPS 48-300W – Standard 1 RU, 19” Shelf

Shelf p/n 0300072

o 1RU 19” - 3 module shelf

o Mechanicals

• mm: 43H (1U) x 440W x 250D

• In: 1.75H x 17.3W x 9.45D

• Weight: 2kg (6.6lb)

Electrical

o AC Input: 90 to 265 Vac, single phase

o Input current (per module)

• 1.4A @ 230Vac

• 3A @ 110Vac

• 3.7A @ 90Vac

o Output voltage: 43-58Vdc

o Power output: 300W per module

2RU Front Access Shelf

Up to (4) 1.2kW Rectifiers; 100A Max @ 48Vdc 2RU High, 19/23” Universal Rack Mount Complete Front Access Connections CXCM1 Controller (Modular CXCi) Battery LVD and Battery Shunt (2) IEC AC Line Cord Connections (2) Battery Connections Distribution Module

o (4) Plug-In Breakers

o (10) GMT Fuses

1RU Bulk Power Shelves

030-835: Up to (4) 1.2kW Rectifiers; 100A Max @ 48Vdc 030-845: Up to (5) 1.2kW Rectifiers; 125A Max @ 48Vdc 1RU High, 19/23” Universal Rack Mount Rear Access Connections CXCM1 Controller (Modular CXCi) IEC AC Line Cord Connections Bus Bar Output w/ 3/8”-1”C Connex Shelf: 1.75”H x 17.3”W x 12”D System: 5.3”H x 17.3” W x 15”D

Shelf Type DC System-TT-DSLAM

Project

TT-NATO-TAFICS

Enclosure Solutions for oDAS Applications

Monitoring

Comp@s & Arm@da

Topology

Energy systems for cellular base stations

Non-system variables can be measured

Site management through Comp@s communication card

Remote Site 1

Arm@da

DB

DB

Remote Site 2

DB

Comp@s Comp@s

Measured parameters

RF module 3

System module

Rectifier Site power input

Battery • cooling

• other

230V - AC 48V - DC

Site support system

RF module 2

RF module 1

Client Interface Overview

FTTx Networks

The core of voice, data and video transmission is fiber, but electronics is still needed to translate sounds and images into pulses of light for transmission and back again to electronics for hearing and viewing. The electronics would always require a reliable sources of DC power.

“Who will provide this power, and

where will it be located?”

ONU – Optical network Unit (multi premise)

ONT – Optical Network Terminal (single premise)

deployment

Under test/evaluation

Competitors

No firm plans yet

Fiber to the home, no need for power

N°1 position in W-Europe DSL/Broadband

networks

> 50% of European market access networks

Several examples: Deutsche Telekom Germany

NTG 2005

+/- 15 kpcs

NTG 2007

+/- 8 kpcs (4100 + 3550)

Deutsche Telekom Germany

NTG 2005

+/- 15 kpcs

NTG 2007

+/- 8 kpcs (4100 + 3550)

Belgacom Belgium

Different systems

– Local Powering

• 2 x 400W > 20.000 deployed

• 3 x 400 W for All IP application +/- 1.000 deployed

• 2 x 140 W FO application +/- 1.000 deployed

Battery mgt

Monitoring Rectifier Rectifier Rectifier

Outputs

Fan

PT Portugal

Remote Powering2 x 60W

2 x 600W

OTE Greece

Remote Powering 3 x 120W

OTE Greece 1U, 2 x 850W KPN Netherlands

Output breakers

4x30A 2x6A

Output breakers

4x30A 2x6A

Battery connector &

breaker 80A

Battery connector &

breaker 80A

Output connectors 6xOutput connectors 6x

Up to 4 x 850W CAR0948TN rectifiersUp to 4 x 850W CAR0948TN rectifiers

> 4.000 deployed

Line Powering

• A means of energizing remote equipment from a centralized location

over outside plant (OSP) over telecom twisted copper cable

• Also known as remote power, network power, centralized power, span

power

• DC-DC Converters are used to convert from a standard 48V system to a high DC voltage, transmitted over multiple copper power pairs, and down-converted back to 48VDC at the load equipment end.

• Used for decades in telecom networks for various tasks, such as the coin return mechanism of payphones, T-1 repeater powering, HDSL remote unit powering, FTTC powering, etc.

• Used today for powering DAS, DSLAMs, mini-DSLAMs, and FTTH

Typical Line Powering Architecture

Upstream Converter •Converts 48Vdc to +/-190Vdc

•Located in CO (indoor) or remote

power node (outdoor)

Downstream Converter •Converts 200-380Vdc to 48Vdc

•May be integrated into access

equipment’s power supply

•Typically located outdoor

UltraCapacitor •Provides short duration

backup for increased backup

•Parallels onto 48Vdc bus

•Optional accessory

Line Power Reach

Target Application 1: CO Powered DSLAM

• Up converters located in CO

• DSLAM cabinet powered by multiple down converters

• No AC utility or batteries at DSLAM site

• Battery backup provided by reliable CO power plant

Fiber Ethernet

Switch

Up

Converters

Central Office

PSTN

IP

BATT

POTS + xDSL

DSLAM Cabinet

-48Vdc ~ = = =

Down

Converters ±190 Vdc

D

S

L

A

M

~ = = =

Target Application 2: Remote Power Node

• RPN cabinet powered by AC, rectifiers & batteries

• Mini-DSLAM (aka sealed DSLAM) powered by up converters at RPN

• Integrated down converter included in Mini-DSLAM

- or -

• Standalone dual channel 48Vdc down converter for high load Mini-DSLAMs

POTS + xDSL

Remote Power Node Mini-DSLAM

Up Converters

Utility AC

±190 Vdc

+ - Rectifiers

Batteries

+ -

~ =

= =

Fiber

Target Application 3: Fiber to the Home

• Optical Line Terminal (OLT) powered by -48Vdc in CO

• DC-DC up converters in CO provide 190Vdc to Optical Network Terminal (ONT)

• ONT powered by standalone down converter(s)

o 12V for single family unit

o 48V for multiple dwelling unit

±190 VDC

12 or 48 Vdc

Down

Converter

ONT

Central Office

Optical

Line

Terminal

Fiber

BATT Up

Converter

POTS, Data & Video

PSTN

IP

~ = = = = =

Target Application 4: Metropolitan WiFi

• RPN cabinet powered by AC, rectifiers & batteries

• DC-DC up converters in RPN provide 190Vdc to WiFi Access Point

• Access Point powered by standalone down converter(s) providing 12 or 48Vdc

• No need for AC service

±190 VDC

12 or 48 Vdc

Down-Converter

Fiber

WiFi Access Point

= =

Remote Power Node

+ -

Batteries

+ -

~ =

= =

LPS04 4-ch. Sealed

Up-Converter

Utility AC

Rectifiers

= =

12 or 48 Vdc

Local vs Line Powering CapEx Comparison

Fiber Ethernet

Switch

Up

Converters

Central Office

PSTN

IP

BATT

POTS + xDSL

mini-DSLAM Cabinet

-48Vdc ~ = = =

5 x Down

Converters ±190 Vdc

M

i

n

i-

D

S

L

A

M

~ = = =

$1013

10 x 24 AWG Pairs

$1120

Fiber Ethernet

Switch PSTN

IP

BATT

POTS + xDSL

-48Vdc ~ =

M

i

n

i-

D

S

L

A

M

~ =

$0 $1700

AC Service

$1450

BATT

-48Vdc

~ = ~ =

$600

$3750

$2133

Line

Powering

Local

Powering

Line Power Benefits

Avoids proliferation of batteries at the far end of the network

Minimizes the need for accessing AC service

Capitalizes on high reliability, low maintenance

central battery and power system

Uses existing copper cable plant

Reduce time to market & Enables rapid deployment

Reduces CapEx and OpEx

ALPHA Group

INDUSTRIAL POWER SOLUTIONS

ALPHA Group

INDUSTRIAL POWER SOLUTIONS

ALPHA SCR type Charger Series

STANDART Systems SPECTRA I

• Single Phase 6 pulse

• Output Voltage: 24, 48, 130Vdc

• Output Amps: 6, 12, 18, 20, 25, 50

• Made in USA

SPECTRA II

• Single and Three Phase (6 / 12 Pulse)

• Output Voltage: 12V ~ 600V

• Output Amps:Single Phase: 5 ~ 400 ; Three Phase: 25 ~ 1000

• Made in Italy

CUSTOMIZED Systems • Single and Three Phase 6 pulse,

• Output Voltage: 24, 48, 110, 220Vdc

• Output Amps: Single Phase: 10~ 100A ; Three Phase: 30 ~ 600A

• Made in Turkey

ACS:ALPHA Charger Systems

ACS 125/250 HP Series • Single or Three Phases Input

• Output Voltage: 125 and 240Vdc

• Redundant N+1

• Filtering and Communications Package Included

• Hot Swappable

• 1.1kw (natual cooled) OR 4.4kw (forced cooled) SMPS rectifier

modules

• LCD Touch Screen Controller with WEB interface

• Customized solutions for different sizes

• Made in USA, Belgium, Turkey

220VDC/1000A

24VDC/3600A

3 x415VacIN /220VDC bus/1X120VAC OUT Ind.UPS-GE-Gas Turbine Powering

48VDC/24VDC/220VAC Output

Ind.UPS/Oil and Gas

Ind.UPS /Railway