75*All bending radii shown are indicative only as each individual manufacturer has their own criteria for their product. Specification of the minimum bending radius(MBR) of cables is not referred to in cable standards. This is a manufacturer declaration, based on their own judgement and experience of the capabilities oftheir cable, it is not a specification defined in standards.

Please note that gland and cleat sizes are intended to be indicative and may vary according to different manufacturers tolerances.

Flexible Cables, PVC And Rubber

Temperature limits:-35 to +65°C.

*Bending radius:10 x overall diameter.

Core identification:4 core - Black, Grey, Brown,Green/Yellow.7 and 12 core - Black coreswith White numbers and oneGreen/Yellow.

Should not be installed attemperatures below 0°C.

RUBBER FLATFORM CABLESFlexible plain copper conductors, thermoplastic rubber insulated (TPR) thermoplastic outer sheath(TPR). Black. 450/750V volts grade. Type H07RNH6-F. CCC Conductor Stranding No. Of Weight Overall Max Current Size (mm) Cores (Kg/Km) Dimensions Ratings Code (mm2) (mm) (Amps)FLAT4X1/5R 1.5 30/0.25 4 110 17.01X5.00 22FLAT12X1/5R 1.5 30/0.25 12 320 46.93X8.87 12FLAT4X2/5R 2.5 50/0.25 4 170 19.98X7.43 30FLAT7X2/5R 2.5 50/0.25 7 300 38.11X10.74 20FLAT12X2/5R 2.5 50/0.25 12 490 53.93X8.88 20 FLAT4X4R 4 56/0.30 4 250 23.05X8.63 40 FLAT4X6R 6 84/0.30 4 330 28.55X9.56 52FLAT4X10R 10 80/0.40 4 550 31.85X10.66 70 FLAT4X16R 16 126/0.40 4 800 38.77X13.51 95FLAT4X25R 25 196/0.40 4 1350 49.10X11.00 127FLAT4X35R 35 276/0.40 4 1800 55.20X15.01 157FLAT4X50R 50 396/0.40 4 2400 63.10X17.20 190FLAT4X70R 70 360/0.50 4 3250 71.10X19.01 242

Temperature limits:-20 to +85°C.

*Bending radius:8 x overall diameter.

WELDING CABLES 0361TQTinned annealed flexible circular copper conductors, ethylene propylene rubber (EPR) insulated,chlorosulphonated polyethylene (CSP) outer sheath. Orange. Ref 0361TQ. To BS638 Part 4. Flameretardant to BS EN 60332-1-2 (BS EN 50265-2-1). CCC Conductor Stranding Weight Outside Gland Code Size (mm) (Kg/Km) Diameter Size (mm2) (mm) (mm) 0361TQ16OR 16 513/0.20 235 11.50 20S0361TQ25OR 25 783/0.20 330 13.00 200361TQ35OR 35 1107/0.20 440 14.50 250361TQ50OR 50 1566/0.20 610 17.00 250361TQ70OR 70 2214/0.20 840 19.50 320361TQ95OR 95 2997/0.20 1120 22.00 320361TQ120OR 120 608/0.50 1410 24.00 320361TQ185OR 185 925/0.50 2100 29.00 40