Key Features & Benefits
— Control module for all of the following: – 0-10V dimmable luminaires – DALI ballasts – Occupancy sensors
— ENCELIUM GreenBus II® connection available for GreenBus II devices
— Connects 0-10V dimmable luminaires to network for: – Customizing lighting scenes for tailored experiences/tasks – Adjusting light levels to respond to variable lighting requirements
The Wireless Control Module (WCM) is a key component of the ENCELIUM Energy Management System (EMS). This device allows luminaires and occupancy sensors to communicate via a mesh network based on ZigBee® standards. Individually addressable, the WCM enables each ballast or LED driver to be independently controlled and configured to best meet the needs of the facility.
The WCM switches a fixture ON or OFF via a relay contained in the module as well as delivers a low voltage dimming signal to any 0-10V dimming ballast/driver. A WCM can be connected to LED drivers without isolation between the dimming section and the electrical output for added flexibility in LED driver options.
OSRAM offers a special Damp-Rated (DR) WCM for installations subject to moderate degrees of moisture.
The WCM is compatible to ENCELIUM hardwired products via the GreenBus II port on the device. This enhances the flexibility of the system to include phase-cut dimming, area lighting control and relay panel control.
Wireless Control ModuleENCELIUM® Energy Management System – Hardware
www.encelium.com
LMS103R1 7-15
ENCELIUM Wireless and ENCELIUM GreenBus II®
Communication Networks
ENCELIUM Wireless Energy Management System Architecture
System ArchitectureThis illustration shows how each component is easily integrated into the ENCELIUM Wireless Energy Management System (EMS). The ENCELIUM Wireless system commu-nicates via a mesh network based on ZigBee standards. The WCM is powered by incom-ing line voltage. Each WCM, sensor, and wallstation uses a wireless mesh network to relay data back to the Wireless Manager (WM). WMs typically control individual floors and are linked via an Ethernet Network back to the SSU. Internet or LAN connection allow floor plan based control software via Polaris 3D® to be operated anywhere on the network. For reference, the component shown on this data sheet is highlighted.
WCM
Light Fixture
WirelessWall Station
PoE Switch
ENC
ELIU
M E
ther
net N
etw
ork
Low-VoltageSensor
Polaris 3D®/PCS/PCW
FLO
OR
1FL
OO
R 2 Light Fixture
SSU
WCM
Router
WM
WM
Polaris 3D®
Tenant EthernetNetwork
SIM
GreenBus II®
Line Power & Dimming
to switch leg
Max ambient temperature +50ºCInput: Class 2 Only24V AC, 50/60Hz, min 40VA Relay Panel ModuleEN-RPM-24C-GB2
Install per installation instruction sheet and electrical & building codes. Connect to ENCELIUM GreenBusII System only.CAUTION - To Reduce the Risk of Fire or Electric Shock Do Not Interconnect The Outputs Of Different Class 2 Circuits85-116-DA
Item No 45268
Q1Q2Q3Q4Made in Canada2012201320142015Emergency Lightingand Power EquipmentEnergy Management Equipment Subassembly6NA8
AC Phase Cut
Dimming Fixtures
WCM
WCM
Relay Panel
PCDM
ALC
WirelessSensor
Line Power
UL USC
Ordering Information
Item Number Ordering Description Communication Network Modifiers45572 EN-WCM-ZB-DR ZigBee® Wireless - Damp-Rated -DR 45583 EN-WCM-ZB ZigBee Wireless
Specifications
— 3.17" x 1.64" x 1.27" (80.42mm x 41.6mm x 32.31mm)
— Operating temperature range: -40°C (-40°F) to 60°C (140°F)
— Suitable for luminaire or junction box mounting in standard 1/2" knockout (7/8" dia.)
— Absolute Maximum Ratings 300W (all rated voltages have a tolerance of +/-10%): – 4.5A 120-347 Vac Ballast/LED Driver – 5.8A 120-347 Vac Tungsten – 9.0A 120-347 Vac General Purpose
— Single 0-10V dimming output (IEC 60929 Annex E). Capable of sinking 10mA (this is equivalent to 10 typical dimming ballasts/drivers)
— Standard units are for indoor use only or for mounting inside waterproof enclosure
— Damp-rated units may be used in damp locations
— Radio Properties - 2.4 GHz
— Wireless Range: 100' line of sight, 50' through standard walls when WCM is mounted exterior to the luminaire – Range decreases by 50% when mounted inside the luminaire
— Safety approvals: – Energy Management Equipment (UL 916) – Emergency Lighting Equipment (UL 924 cULus Listed) – Heat and Smoke Release for Air-Handling Spaces (UL 2043)
— 0-10V or DALI connectivity
— ENCELIUM GreenBus II connection port for GreenBus II devices
— Complies with the following electromagnetic requirements: – EN 61000-4-2 – EN 61000-4-4 – EN 61000-4-5
— FCC Part 15/ICES-003
Installation Diagram
Dimensions
The mechanical construction allows for simple installation of the WCM to an available 1/2 inch knock-out on the side or on top of a fixture (as shown below). All necessary wiring for the electronic dimming ballast or LED driver is available on the inside.
For some installations, a junction box may be required. It is recommended to securely mount the WCM to the junction box (as shown below) using an available 1/2 inch knock-out and a retainer nut.
WCM
(32.
31m
m)
1.27
”
0.96
”(2
4.31
mm
)
(31.
31m
m)
1.23
”
1.64
”(4
1.60
mm
)
3.17”(80.42mm)
Fixture
WCM
J Box MountingFixture Mounting
OSRAM is a registered trademark of OSRAM GmbH. ENCELIUM, GreenBus II and Polaris 3D are registered trademarks. ZigBee is a registered trademark of ZigBee Alliance. Specifications subject to change without notice.
Americas Headquarters
OSRAM SYLVANIA Inc.
100 Endicott Street
Danvers, MA 01923 USA
Phone 1-888-531-7571
www.encelium.com
© 2015 OSRAM
Wire Table
Wire Color Wiring to Luminaire Wiring to Low Voltage Sensor Wiring Using GreenBus II Port Only Wire LengthBLACK Line In - Relay Contact Line In - Relay Contact Line In 9.84" (250mm)RED Line Out - Relay Contact Not Used Not Used 9.84" (250mm)WHITE Neutral Neutral (WCM Input Only) Neutral 9.84" (250mm)VIOLET Class 2, Low Voltage, 0-10Vdc, 10mA max. Power Not Used 23.62" (600mm)GREY Class 2, Low Voltage Return/Common Common Not Used 23.62" (600mm)BLUE Not Used Signal Not Used 7.09" (180mm) Note: GreenBus II port can also be used when wiring to a luminaire.
Wiring Diagrams
Power Feed
BLACK
ENIL
LARTUEN
RED
GREY GREY/ -VIOLET VIOLET/ + 0-10V ELECTRONIC
BALLAST/DRIVER
LARTUEN
BLUE BLUE NOT USED
Wiring to Luminaire Wiring to Low Voltage Sensor
Power Feed
BLACK
ENIL
LARTUEN
RED
GREY GREY/ -VIOLET VIOLET/ + POWER
LARTUEN
BLUE BLUE SIGNAL
NOT USED
COMMON
Power Feed
BLACK
LINE
NEUT
RAL
RED
GREY GREY/ -VIOLET VIOLET/ + NOT USED
NOT USEDBLUE BLUE NOT USED
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
BLUE
INP
UT
RED
OU
TPU
T
41
Relays Relays
2
3
1
2
3
Power supply input24V AC, 60Hz, 1.6A (40VA)Class 2 only
Power fail input
GreenBusII . Connect to Energy Management System only.
Manual Toggle Button
TM
blue
red
WRRelays
blackbluered
GERelays
Depress with tool to unlock
1 23 45 67 89 1011 1213 1415 1617 1819 2021 2223 24
4
TMLED Always On -> 24V and GreenBusII PresentLED Single Blink -> Only GreenBusII PresentLED Double Blink -> Only 24 VAC Present
TM
Max ambient temperature +50ºC
Input: Class 2 Only24V AC, 50/60Hz, min 40VA
Relay Panel ModuleEN-RPM-24C-GB2
Install per installation instruction sheet and electrical & building codes. Connect to ENCELIUM
GreenBusII System only.
CAUTION - To Reduce the Risk of Fire or Electric Shock Do Not
Interconnect The Outputs Of Different Class 2 Circuits 85
-116
-DA
Item No 45268
Q1 Q2 Q3 Q4
Made in Canada
2012 2013 2014 2015
Emergency Lightingand Power Equipment
Energy Management Equipment Subassembly
6NA8
or or
PCDM
Relay Panel
ALC WCM
NEUTRAL
Wiring Using GreenBus II Port Only
Recommended