jamia polytechnique delhi

Preview:

DESCRIPTION

fire services

Citation preview

BUILDING SERVICES

STUDY ON FIRE SERVICES…PRESENTED BY-Aiman NaseemSundus HussainM.RaghibBilal KhanHamzah Meraj

CONTENTS1. Introduction2. Floor plans3.Entrance4.Corridors5. Classrooms6.Lift7.Staircase8. Basement9. Fire Extinguishers & Refuge Area10. Fire Alarm Control Panel11. Illumination & Sign boards12. Fire Hydrant Chamber & Fire Hose Reel13. Fire Extractors 14.Water Tanks15. Construction16. Other fire Services

UNIVERSITY POLYTECHNIC

Approach- Main road- M.M.A Johar Road, JMI

Height of the building- 26m

Numbers of floors- 05

Occupancy per floor- 300-350 persons

FLOOR PLANS

I. Typical Floor PlanII. Terrace PlanIII. Service Plan

TYPICAL FLOOR PLAN

Fire Staircase Corridor

Entrance/Exit

Classrooms

Classrooms

Classrooms

ClassroomsClassrooms

Lift

FHC

FHC

FHC

9m

9m

4.5m

17m

2m

Smoke detectors in Classroom

2m

4m

Smoke detectors in Lecture hall

4.5m

BASEMENT1.Basement floor plan2.Services

BASEMENT SERVICE PLAN

Main Sprinkler pipe-65 mm dia

Branch Sprinkler pipe- 25mm dia

Fire Exit

Ramp for Exit

Smoke Extractors

9m

9 Sprinklers are provided in area of 9x9m

1.5m 3m 3m 1.5m

14m

18 Sprinklers are provided in an area of 14x8m

• Openable windows on external walls are fitted with such locks that can be opened by a fireman’s axe.

• Sprinklers are provided in the basement.

• Mechanical extractors for smoke venting system are provided.

• Fire Extinguishers provided & Signage available.

• Fire Hose reel provided in the basement.

• Fire Alarm located on the service core and at regular system.

TERRACE PLAN

Lift

Water tank

Fire tank

1.Lecture Hall• 17x8m- 140students• No of smoke detectors-8

2. Classroom• 9mx9m for 70 students.• No of smoke detecators-03

• Smoke Detectors are provided on the ceiling.

• Exit signs on the doors are pasted, but without illumination.

• No fire extinguisher present within the Hall. • Smoke Detectors

• 2500mm wide corridor

• Corridors are fitted with Smoke Detectors But no Sprinklers provided.

• Fire alarm is provided.

• ‘Panic button’ with breakable glass is provided in the corridors.

• Signage at regular interval provided for exit.

CORRIDORS

• No Fire Lift Provided.

• Lift floor area -2400mmx2100mm• Has a loading capacity of 545kg(10

persons) • Width of door.-1000mm

• Communication facilities are provided in lift cars.

• A sign is been pasted and maintained on the lift indicating that in case of fire occupants shall use the stairs.

• Lifts are installed in a common enclosures having individual lift separated by walls

LIFT

STAIRCASEI. Normal StairsII. Fire Stairs

• Width of the Stair-1500mm

• Stair type- Circular & Winder

• Fire Exit Signage provided near to staircase.

1. Normal Staircase 2.Fire Stairs

• Width of Stair-2000mm

• Height of riser-150mm

Fire extinguishers &

Refuge Area

• Type of fire extinguishers-ABC with ISI certification mark.

• 2 extinguishers for every floor is been provided.

• 1 fire extinguisher each in lab, near to electrical installation & generator room is been provided.

• Refuge area has been provided on the 4th Floor.

FIRE ALARM CONTROL PANEL

• Fire control panel is provided on each floor of the building.

• The panel receives information from environmental sensors, such as heat detectors or smoke detectors designed to detect changes associated with fire.

• In fire condition, the fire alarm control panel indicates where the fire originated.

Illumination &

Sign Boards

• No Emergency lights provided in the staircase and corridor.

• Sign boards ‘Fire Exit’ over the Lift and near to stairs are provided.

• Sign posted without illuminated sign for, all exits and direction of travel to each exit.

• No Fire plan for each floor showing the locations of the stairways.

FIRE HYDRANT CHAMBER(FHC)

&FIRE HOSE REELS

• Chamber area- 0.7mx1.3m

• A hose reel, 30m long and fitted with 19mm diameter nozzle at the end of it.

• One Fire Hydrant Chamber on each floor of the building is provided.

FIRE EXTRACTORS& FIRE DAMPERS

• Fire Extractors provided only in the basement area.

• Fire Dampers are located in return air ducts.

• Fire Dampers in fire prevent the spread of smoke inside the ducts.

• When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at higher temperatures.

FIRE DAMPERS

WATER TANKS

I. Fire tank.II. Domestic water tank.

• Fire tank capacity- 25klts• Area-16.9sqm

• Domestic water tank capacity- 20klts• Area-15.3

Fire water supply Pipes

Domestic water supply Pipes

CONSTRUCTION1.Comustibility2.Material

• All materials of constructions in load bearing elements, stairways & corridors and facades are non-combustible.

• The internal walls & staircase are of brick & somewhere with reinforced concrete with a minimum of 2h fire rating.

• Facade treatments is non combustible because of the use of exposed brick.

1.Comustibility Properties

2. MATERIALS

Flooring materials•Terrazzo•Marble•Tiles

Tiles as a flooring material

Terrazo as a flooring material

Materials for walls•Tiles•Cement plaster

OTHER FIRE SERVICESFacilities Which are necessary to be provided in case of fire which were not present in our CASESTUDY.

1.Call box2.Control Rooms3.Materials (Non Combustible04.Denchers

1.CALL BOX

A callbox is a box containing a special-purpose direct line telephone.

Call boxes should be I. Located at each floor. II. One or more should be provided on the floor.III. Accessible within 22.5m.IV. Call boxes shall be wired in a close circuit.V. At a height of 1m from the floor level.

• There shall be a control room on the entrance floor of the building with communication system to all floors.

• Details of all floor plans along with the detail of fire fighting equipment and installations shall be maintained in the control room.

2.CONTROL ROOM

3.Materials

Fire proofing material for walls•Gypsum plaster•Cementetious plaster•Fibrous plaster•Intumescent fire proofing

Fire proofing material for floors•PCC•Terrazo•Tiles

• A drencher fire control system provides a discharge of water over roofs, walls and windows to prevent fire spreading from or to adjacent buildings.

• Drencher systems provide the necessary

curtain of water for protection against

internal and external exposure to fire.

4.DRENCHERS

THANK YOU