Contact shock freezer for blood plasma

Preview:

Citation preview

BY- Authentic instruments

PRESENTATION

Centre of excellence in instrumentation.

Authentic Instrument & Auto Pvt Ltd (Authentic Instruments)

Works: 31, RIICO Jhotwara Industrial Area, Jaipur- 302013

website- www.authenticinstruments.com

cell nos: 09314529100,0935254200-300-400,

E-mail: support@authenticinstruments.com, authenticop@gmail.com

BUSINESS PROFILE Established in the year

1998

Manufacturing Blood Bank .

Clinical lab Calibration lab

Industrial testing Equipments

infrastructure

l  Factory & showroom easy approachable In jaipur,5-6 kms bus stand/railway station. l  25,000 sq feet well constructed covered area

with very good house-keeping. l  All appropriate manufacturing equipments. l  All calibration equipments for Product testing. l  Show room-3,000 sq feet. l  Training cum production and service centre at sambhar lake govt iti under ppp

High Performance Contact Shock Freezers

l  High Performance Contact Shock Freezers are designed for the fast freezing of blood plasma, preparations to a core temperature of (-30°C).

with chamber (-80°c) as per drug act l  Safety of law and compliance with directives for

the preparation of blood plasma storage at a core temperature of < -30°C.

Basics

l  The horizontal freezing technique with high-performance contact plates provides

l  plasmas frozen to the core in uniformly shaped bags. This makes optimum use

l  of the storage capacities inside instruments and transport containers, improves

l  better factor 8

High Performance Contact Shock Freezers

l  High Performance Contact Shock Freezers are designed for the fast freezing of blood plasma, preparations to a core temperature of (-30°C).

with chamber (-80°c) as per drug act l  Safety of law and compliance with directives for

the preparation of blood plasma storage at a core temperature of < -30°C.

High Performance Contact Shock Freezers user in india Sr nos Name of organisation location company

1 Swasthya kalyan blood bank jaipur authentic

2 SDMH blood bank jaipur authentic

3 Govt medical college azamgarh authentic

4 City blood bank raipur authentic

5 Govt Sms hospital Jaipur authentic

6 SGPGI lucknow Dometic

7 PGI CHANDIGARH Dometic

8 AIIMS DELHI DOMETIC

9 NIZAM INSTITUTE HYDERBAD DOMETIC

10 RELAINCE BOMBAY DOMETIC

11 SAHARA HOSPITAL LUCHNOW DOMETIC

Contact shock (blast frezzer)

Controll panel of blast freezer

Various    elements  exist  in  the  plasma(  FFP)  as  shown  in  the  table  could  be  frac:onate  by  proper  processing  of  the  whole  blood  to    fresh  frozen  plasma.  

Protein   Concentra,on  in  Plasma  In  200  mL   In  1  litre   Iden,fica,on  

Albumin   40  g/L   8  g   40g   Volume  restora,on  a9er  trauma,  shock,  bums  Alpha1  proteinase  inhibitor   1.5mg/mL   300  mg   1500  mg   Hereditary  emphysema  An:-­‐D  IgG   Titer  variesa   -­‐-­‐-­‐-­‐-­‐   -­‐-­‐-­‐-­‐-­‐   Rh  prophylaxis  in  pregnancy  and  childbirth  An:thrombin  III   100  µg/mL   20  mg   100  mg   An,thrombin  III  deficiency  C1-­‐Inhibitor   170  µg/mL   34  mg   170  mg   Hereditary  angloedema  Factor  IX   10  µg/mL   2  mg   10  mg   Hemaphilia  B  Factor  VIII   `0.5  µg/L   100  µg   500  µg   Factor  VIII  deficiency  Factor  XI   0.3  µg/mL   60  µg   300  µg   Hemophilia  B  Factor  XIII   30  µg/mL   6  mg   30  mg   Factor  XIII  deficiency  Fibrinogen                    3  g/L                                             0.6  g   3  g   Tissue  sealant  Component  Fibronec:n   300µg/mL   60  mg   300  g   Wound  healing  Hepa::s  B  lgG   Titer  variesa  

-­‐-­‐-­‐-­‐   -­‐-­‐-­‐-­‐  HepaiJs  immunity  

Immunoglobulin  G   Up  to  12.5  g/L   2.5  g   12.5  g   Primary  and  secondary  immune  deficiency  Measles  lgG   Titer  variesa  

       Measles  protec,on  and  treatment  

Protein  C              4µg/mL   800  µg   4000  µg   Neonatal  thrombosis  Rables  lgG   Titer  variesa  

-­‐-­‐-­‐-­‐   -­‐-­‐-­‐-­‐-­‐-­‐  Rables  risk  

Tetanus  lgG   Titer  variesa  -­‐-­‐-­‐-­‐   -­‐-­‐-­‐-­‐-­‐-­‐  

Tetanus  protec,on  and  treatment  

Thrombin   150µg/mLb  30  mg   150  g  

Tissue  sealant  component  

Varicella  Zoster  lgG   Titer  variesa  -­‐-­‐-­‐-­‐   -­‐-­‐-­‐-­‐  

Chicken  pox  protec,on  

Von  willebrand  factor                            10µg   -­‐-­‐-­‐-­‐   -­‐-­‐-­‐-­‐-­‐   Von  Willebrand’s  disease  

S.O.P  for  Plasma  making  Process-­‐  Control  Points  Ø Dona:on  at  50  to  100  mL/minutes,  Approx  450  mL  with  sagam. Ø Store  at  room  temperature  for  1  hour  to  stabilize  the  temperature  ≈  22⁰  C.

 (Pre  CBC  test)  Ø So_  Spin  for  PRP  (Platelet  Rich  Plasma):  During  the  procedure  no  any  cell  should  rupture.

-­‐-­‐-­‐-­‐-­‐-­‐-­‐-­‐-­‐-­‐-­‐-­‐-­‐-­‐-­‐  (  Test  of  Pack  Cells)  Ø Hard  Spin  for      plaelet  concemntrate    (post  cbc  test)  a_er  6  hours  of  Agita:on. Ø Plasma:  ≈  220  mL  (180-­‐200  mL)-­‐-­‐-­‐-­‐  max-­‐(50-­‐55%)  with  the  help  of  "authen:c"  centrifuge    cbc  test  to  valuate  

Ø Plasma  should  be  frozen  within  6  hours  of  dona:on  to  Core  temperature  (-­‐35    ͦC)    within  45  miutes  of  Plasma    with  the  help  of  "authen:c"  contact  shock  /blast  freezer    (-­‐80°  C)  as  per  drug  act.

fresh  frozen  plasma  should  store  at  (below  to  -­‐30  ͦC    )  without    fail  

Infrastructure - showroom

infrastructure

PRODUCTS (Manufactured by Authentic Instruments)

l  Complete Blood Bank equipments

QUALITY POLICY

l Timely Product delivery l Consistent Product Reliability l Optimized performances l Timely service responsiveness

CERTIFICATIONS

l  ISO 9001:2000 Quality Certification

l  Registered with NSIC & MSME

l  Rajasthan’s 1st biggest scope NABL for calibration (Mechanical,electro-technical,thermal)

l  CE Marking

Our Capabilities

l  Real technicalCustomer Support l  Skilled Staff l  Quality Production l  Safety Measures l  Corporate Manners l  After Sales service l  Long business run capability

WHY only ‘Authentic’ ?

l  We have already prove our technical capabilities. l  We are the only manufacturer in India who is producing

full range of blood bank equipments and calibration services.

l  We have cut down the prices of the expensive imported blood bank equipment by introducing our products.

l  Technical manpower backup from own govt iti under ppp training cum service and production centre at govt iti ( industrial training institute) sambhar lake

jaipur.

1/2

WHY only ‘Authentic’ ?

l  We have provided these equipments to a 75% cheaper rate than the imported ones.

l  One of the product, (-80) Degree Contact Shock freezer is manufactured in INDIA only by Authentic Instruments.

l  Rajasthan’s biggest scope NABL accredited

Calibration Laboratory which can be utilized for calibrating almost any industrial & medical equipment.

2/2

Technical training backups

l  Training cum service and production centre at govt iti ( industrial training institute) sambhar lake

jaipur,For more visit us at

l www.gitisambhar.com

What we will earn?

“We are into a business of caring people”

NABL ACCREDITED LAB

Thermal-c-688,electro-tech-c-686,mechanical-c-687 NABL Accredited Laboratory for calibration.

(deptt of science and technology,govt of India)

for more details- www.nabl-india.org

We will earn…. l  Corporate social responsibility is served. l  We will earn an esteemed position in the Society l  We will earn a good Brand Value.