H Gopalan
Editor, www.orthopaedicprinciples.com
Expert Advisor, www.myorthoevidence.com
SICOT India ICL Course Director
Patient Specific Instrumentation
• Customisedinstruments for every patient
•Need for CT/MRI earlier
• Reduces inventory
Level 2 Meta analysis•7 RCT
• Higher incidence of tibial component malaligment in PSI
Thienpont E et al..BJJ Aug 2014
Computer Navigation in TKA
Navigation: 21 RCTsMechanical Axis Deviation, Femoral and
Tibial Component Alignment: < 3 degree
CAS : <3 degrees
CAS took longer time
Lutzner J et al.. 2013
• Superior Alignment < 3 degree: Can it affect revision rates?
•Cost effectiveness
High Flexion in TKA
•Choi WC JBJS Am 2010•Kim JBJS Am 2009
•Nieuwenhuijse JBJS Am 2013 RSA- Implant migration.
NO DIFFERENCE
• Knee Society scores• HSS Knee Score• WOMAC • SF- 36 scores
Oxinium
• Surface coating of Oxinium
•Coating is oxidised Zirconium, superior wear properties
•? Wear rates
Kim WH 2012
KSS, WOMAC, ROM, UCLA score for post op mobility
Osteolysis, Patellar tilt, Subluxation,
Wear particle analysis: Aspiration
NO DIFFERENCE
Cementless TKA
• Younger patients
• Circumvent Asceptic Loosening
•Prosthesis survival
Cementless TKA
• 93 patients
• 9 year survival
• 93.7 % in cementless Vs 90 % cemented group
Lizuar Utrill A et al.. 2014
CoC Vs CoP
•Reduced wear rates compared to metal on polyethylene
• CoC- squeaking incidence 2- 7%
CoC Vs CoP: Kim YH 2011
• 200 patients
•Harris hip score, UCLA, WOMAC
• Similar Function and Radiological Outcome
Trabecular Metal
•Cementless TKA
• 145 patients
•Trabecular Metal Vs Standard cemented TKA
•KSS, WOMAC better in trabecularmetal cemetless group
Fernandez- Fairer M et al.. 2013
Uncemented Stem THA
• Uncemented Vs Cemented Hemiarthroplasty
• Expensive
•? Better function, Easier Revision
Cemented Vs Uncemented HA•115 patients in each
• Uncemented group: better Harris hip scores at 5 years
• Periprosthetic fracture: 7.4% in uncementedgroup Vs 0.9% in the cemented group
Accelerometer- Portable Device•100 patients
• No difference tibialcomponent alignment
• Higher time for tibial resection
•Better restoration of mechanical axis
Five Innovations Gender Specific Knee Replacement
Modular necks in THA
High flexion Knee Replacement
Ceramic on Ceramic
Uncemented Monoblock cups
Expose large number of patients to Unknown Implants
Introduction into commercial market
Adverse effect profile
MoMs
Evidence Based Reviews
Evidence Based Practice
Don’t be the first to use new Technology and don’t be the last to ditch it.