1. Test Report issued under the responsibility of lEe:::==.
eTEST REPORT lEe/EN 60065 Audio, Video and Similar Electronic
Apparatus: Safety Requirements Report Reference No.... ........
.... ....... . CEPREI1007CB0506 Hu(IrIiJ} L~)fN I' Tested by (name
+ signature) .......... : Huang Linyi ......... ..:.:..) ...... ...
.J.. .,... .... .. ........... ... Witnessed by (name + signature)
.... : N/A Supervised by (name + signature) .. .: N/A ~. :::: : ...
.::.......:::....::. Approved by (name + signature) .. .. ..: Yang
Lin Date of issue ...... ................. .............: July
22.2010 CB Testing Laboratory................... : China CEPREI
Laboratory Address .. ...................... .. .. .. .. .........
.. : No.110 Dongguanzhuang Rd., Tianhe District, Guangzhou,
Guangdong, 510610, China Testing location/ procedure ...;.. ......
: CBTL ~ RMT D SMT D WMT DTMP D Testing location/ address ..
....... .. .. .. ... : Same as above Applicant's
name............................ : PCF Technology
Development(Shenzhen) Limited Address . . ....... .. ....... ......
... ............... : No.24, 2nd Industrial Zone, Ma'an Shan
Village, Shajing Town, Bao'an District, Shenzhen, China Test
specification: Standard .......................... ....... .. ..
...... : IEC 60065:2001 + A1:2005/ EN 60065:2002 + A1:2006 + A11
:2008 Test procedure ........... .. .. .. .. ...... ...... : CB
Non-standard test method ...... ... .....: N/A Test Report Form
No................:..... : IECEN 60065G Test Report Form(s)
Originator ........ : ASTABEAB Master TRF ....... .. ..............
............... : 2006-03 Copyright 2006 IEC System for Conformity
Testing and Certification of Electrical Equipment (IECEE), Geneva,
Switzerland. All rights reserved. This publication may be
reproduced in whole or in part for non-commercial purposes as long
as the IECEE is acknowledged as copyright owner and source of the
material. IECEE takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of
the reproduced material due to its placement and context. If this
Test Report Form is used by non-IECEE members, the IECEE/IEC logo
shall be removed This report is not valid as a CB Test Report
unless signed by an approved CB Testing Laboratory and appended to
a CB Test Certificate issued by an NCB in accordance with IECEE
02.
3. Page 3 of 112 Report No. : CEPREI1007CB0506 Summary of
testing: The sample(s) tested complies with the requirements of IEC
60065:2001 + A1:2005/ EN 60065:2002 + A1:2006 + A11 :2008.
Compliance with other National Differences recorded at the end of
this report. SummaQ!. of compJiance with National Differences (for
eXQ/anation of codes see be/owl: Group Differences, AR, AT, AU, BE,
BR, CA, CH, CN, CS, CZ, DE, OK, ES, FI, FR, GB, GR, HU, IE, IT, jp,
KR, NL, NO, PL, PT, RU, SE, SG, SI, SK, TR, UA, US, ZA At the time
of issuing this report, only limited countries are listed in CB
bulletin 112A for IEC 60065:2001 + Amd 1:2005, therefore for
reference the National Differences for IEC 60065:1998 and IEC
60065:1985 + Amd 1:1989 + Amd 2:1989 + Amd 3:1992 are included. -
IEC 60065, 7th edition (2001) + Amendment 1 (2005): Group
Differences, AU, CA, DE, OK, GB, NO, SE, US; Onl y group
differences listed: AT, BE, CH, CZ, FI, FR, GR, HU, IT, NL, PL, SI,
SK; No national differences or group differences listed: AR, BR,
CN, CS, jp, KR, PT, RU, SG. -IEC 60065, 6th edition (1998): CN, IT,
jp, KR, UA; Only group differences listed: ES, IE; No national
differences or group differences listed: IN, TR, ZA. - IEC 60065,
5th edition (1985) + Amendment 1 (1989) + Amendment 2 (1989) +
Amendment 3 (1992): FI, PL, SG. (AR= Argentina, AT= Austria, AU=
Australia/New Zealand, BE= Belgium, BR= Brazil, CA= Canada, CH=
Switzerland, CN= China, CS= Serbia and Montenegro, CZ= Czech
Republic, DE= Germany, DK= Denmark, ES= Spain, FI= Finland, FR=
France, GB= United Kingdom, GR= Greece, HU= Hungary, IE= Ireland,
IT= Italy, JP= Japan, KR= Republic of Korea, NL= Netherlands, NO=
Norway, PL= Poland, PT= Portugal, RU= Ruddian Federation, SE=
Sweden, SG= Singapore, SI= Slovenia, SK= Slovakia, TR= Turkey, UA=
Ukraine, US= United States of America, ZA= South Africa) Tests
performed (name of test and test clause): Clause(s) Test(s) 5.1
Durability of Marking Test 7.1 Temperature rise measurement under
normal operating conditions 9.1.1.1 Touch current measurement 9.1.6
Withdrawal of mains plug 9.1.7 Resistant to external force 10.1
Surge test 10.2 Humidity treatment 10.3 insulation resistance and
dielectric strength 11 .1 Touch current measurement under fault
condition 11.2 Heating under fault condition 12.1. 1 Bump test
12.1.2 Vibration test 12.1.3 Impact hammer test and Steel ball test
12. 1.5 Stress relief test TRF No. IECEN60065G TRF originator:
ASTABEAB
4. Page 4 of 112 Report No.: CEPREI1 007CB0506 Clearance and
creepage distances measurement13 Protective earth terminal
resistance test15.2 Screw fixing test17.1 19.1 Tip stability test
following stress relief conditioning Vertical force stability19.2
Horizontal force stability test19.3 TRF No. IECEN60065G TRF
originator: ASTABEAB
5. Page 50f 112 Report No.: CEPREI1007CB0506 Test item
particulars .................................................. :
LCD TV Classification of installation and use
....................... ..... : Class I Supply connection
...................................... ..................:
detachable power supply cord Possible test case verdicts: - test
case does not apply to the test object.................. : N/A -
test object does meet the requirement ....................... Pass
(P) - test object does not meet the requirement .................:
Fail (F) Testing: Date of receipt of test
items..................................... ..... : 2010.07.05
Date(s) of performance of tests.. ........ .. .......... ..
.............: 2010.07.05 - 2010.07.21 General remarks: The test
results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the
written approval of the Issuing testing laboratory. "(see Enclosure
#)" refers to additional information appended to the report. "(see
appended table)" refers to a table appended to the report.
Throughout this report, a pOi.nt is used as the decimal separator.
List of test equipment must be kept on file and available for
review. General product information: General product information:
The application models 32C21 ,32C12, 32C51 are a LCD TV for use as
AudioNideo apparatus. The test samples are pre-production without
serial number. The application rating is: 100-240V-, 50/60Hz, 180W.
The models 32C21 ,32C12, 32C51 are identical except for their model
designation and colors of appearance. Unless otherwise specified,
all tests were performed on model 32C21 to represent other similar
models. Factory: PCF Technology Development(Shenzhen) Limited
No.24, 2nd Industrial Zone, Ma'an Shan Village, Shajing Town,
Bao'an District, Shenzhen, China EAB TRF No. IECEN60065G TRF
originator: ASTABEAB
6. Page 6 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test IResult - Remark l Verdict 3 GENERAL
REQUIREMENTS P Safety class of the apparatus
............................ .. ... IClass I P 4 GENERAL CONDITIONS
OF TESTS P 41.4 Ventilation instructions require the use of the
test box Test according the specified condition by manufacturer. P
PMARKING5 Comprehensible and easily discernible No misunderstanding
P After rubbing test by water PPermanent durability against water
and petroleum and petroleum spirit, the label still easily
discernible, indelible and legible. spirit Model: 32C21
PIdentification, maker, model ....................................
.5.1 N/AClass II symbol if applicable Class I Rated supply voltage
and symbol .... . .. ........... .. .. ... , 100-240V P Frequency
if safety dependant 50/60Hz P Rated current or power consumption
....... , ....... ...... ' 180W P Earth terminal5.2 The symbol of
IEC 60417 P 5019 was provided on the internal metal enclosure.
Hazardous live terminals N/ANo provided Supply output terminals
(other than mains) N/ANo provided 5.3 Use of triangle with
exclamation mark In circuit diagram P 5.4 Instructions for use
User's manual is provided P in English. Versions in other languages
are to be provided during the corresponding national approval.
5.4.1 Mains powered equipment not exposed to dripping or The
statement is provided P splashing. Warning concerning objects
filled with in user's manual. liquid, etc. Hazardous live
terminals, instructions for wiring N/ANo live terminal Instructions
for replacing lithium battery No lithium battery N/A Instructions
for modem if fitted N/ANo modem TRF No. IECEN60065G TRF originator:
ASTABEAB
7. Page 7 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause I Requirement - Test IResult - Remark I Verdict Class I
earth connection warning Warning was provided in the user's manual.
P Instructions for multimedia system connection Described in the
user manual. P Special stability warning for fixed installation No
special installation N/A Warning: battery exposure to heat No
batteries N/A Warning: protective film on CRT face No CRTs N/A
5.4.2 Disconnect device: plug/coupler or all-pole mains switch
location, accessibility and markings The statement is provided in
user's manual. P Instructions for permanently connected equipment
Not permanently connected equipment. N/A 6 HAZARDOUS RADIATION N/A
6.1 Ionizing radiation < 36 pNkg (0,5 mR/h) No ionizing or laser
radiation in the EUT. N/A 6.1 EN 60065 European Council Directive
96/29/Euratom of 13 May 1996 10cm from outer surface of apparatus
0,2 A at least 150C (see appended table) P 8 CONSTRUCTIONAL
REQUIREMENTS WITH REGARD TO THE PROTECTION AGAINST ELECTRIC SHOCK P
8.1 Conductive parts covered by lacquer, paper, untreated textile
oxide films and beads etc. considered to be bare No lacquer, paper
etc. P EAB TRF No. IECEN60065G TRF originator: ASTABEAB
8. Page 8 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test IResult - Remark I Verdict 8.2 No shock
hazard when changing voltage setting device, fuse-links or handling
drawers etc. No changing voltage setting device etc. N/A 83
Insulation of hazardous live parts not provided by hygroscopic
material No hygroscopic materials P 8.4 No risk of electric shock
following the removal of a cover which can be removed by hand No
risk of electric shock from accessible parts. No cover can be
removed by hand. P 8.5 Class I equipment The apparatus is provided
with a protective earthing terminal to which all accessible
conductive parts are reliably connected. P Basic insulation between
hazardous live parts and earthed accessible parts P Resistors
bridging basic insulation complying with 14.1 a) N/A 8.6 Class"
equipment and Class" constructions within Class I equipment Class"
constructions within Class I equipment. P Reinforced or double
insulation between hazardous live parts and accessible parts The
accessible parts and wiring were separated from the hazardous live
parts by reinforced or double insulation. P Components bridging
reinforced or double insulation complying with 14.1 a) or 14.3
Transformers complies with 14.3, see 14.3 for details. P Basic and
supplementary insulation each being bridged by a capacitor
complying with 14.1 a) No such components used. N/A Reinforced or
double insulation being bridged with 2 capacitors in series
oomplying with 14.2.1 a) No such capacitors used. N/A Reinforced or
double insulation being bridged with a single capacitor complying
with 14.2.1 b) All sources of Y1 capacitors are approved according
to IEC60384-14 P Basic insulation bridged by components complying
with 14.3.4.3 N/A 8.7 This clause is void P 8.8 Basic or
supplementary insulation> 0,4 mm (mm) : P Reinforced
insulation> 0,4 mm (mm) ....................: Optocoupler is
provided distance through insulation of O.4mm min. P Thin sheet
insulation (excluding non-separable thin sheet insulation. See
8.22) Thin sheet insulation is applied in the transformers. See
below. P TRF No. IECEN60065G TRF originator: ASTABEAB
9. 6 Page 9 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test IResult - Remark I Verdict Basic or
supplementary insulation, at least two layers, each meeting 10.3 P
Basic or supplementary insulation, three layers any two of which
meet 10.3 N/A Reinforced insulation, two layers each of which meet
10.3 N/A Reinforced insulation, three layers any two which meet
10.3 Reinforced insulation between the primary side to secondary
side of Transformer consists of three layers of material, each
combination of two meets the dielectric strength test in 10.3. P
8.9 Adequate insulation between internal hazardous live conductors
and accessible parts Provided double insulation P Adequate
insulation between internal hazardous live parts and conductors
connected to accessible parts Provided double insulation P 8.10
Double insulation between conductors connected to the mains and
acces~ible parts. Double insulation betWeen internal hazardous live
parts and conductors connected to accessible parts. Provided double
insulation P 8.11 Detaching of wires No wire could be become
detached. P No undue reduction of creepages or clearance distances
if wires become detached Conductors with mechanical securing,
soldering and sleeves. P Vibration test carried out ........... ..
. .... ..... ....... ........... See clause 12.1.2. P 8.12 This
clause is void N/A 8.13 Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s) No windows, lenses, etc. N/A
.14 Adequate fastening of covers (pull test 50 N for 10 s) No such
covers N/A I 5 No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges No risk of damage P 8.16
Only special supply equipment can be used No special supply
equipment. N/A 1 8 17 Insulated winding wire without additional
interleaved insulation No insulated winding wire with additional
interleaved insulation. N/A 81 8 Endurance test as required by 8.17
N/A 81 9 Disconnection from the mains See below P p BEAB T F No.
IECEN60065G TRF originator: ASTABEAB
10. Page 10 of 112 Report No. : CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test IResult - Remark l Verdict 8.19.1
Disconnect device Appliance inlet is used as disconnect device. P
All-pole switch or circuit breaker with >3mm contact separation
P 8.1 9.2 Mains switch ON indication Symbol (IEC 60417-5010) is
used. P 8.20 Switch not fitted in the mains cord N/A 8.21 Bridging
components comply with clause 14 N/A 8.22 Non-separable thin sheet
material N/A 9 ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING
CONDITIONS P 9.1 Testing on the outside P 9.1.1 For voltages
>1000 V ac or >1500 V dc complies with clause 13.3.1 for
basic insulation P 9.1.1.1 a) Open circuit voltages . The open
circuit voltage does not exceed 60Vdc or 35Vpeak, or complied with
requirement of touch current, see b). P b) Touch current measured
from terminal devices using the network in annex D
............................. Protective earth: U1 : 0.363Vpeak
max. U2: 0.334Vpeak max. Output terminal: U1: 0.174Vpeak max. U2:
0.027Vpeak max. Input votage:264V, frequency:60Hz p c) Discharge
not ~xceeding 45 ~C No part or contact of a terminal carrying
exceeds 45 j.l C for stored charges. P d) Energy of discharge not
exceeding 350 mJ N/A 9.1.1.2 Test with test finger and test probe
No access with test finger to any parts bearing hazardous voltage.
Test pin cannot touch hazardous voltage in the whole enclosure. P
9.1.2 No hazardous live shafts of knobs, handles or levers No
operating knobs, handles, levers used. N/A 9.1.3 Ventilation holes
and other holes tested by means of 4 mm x 100 mm test pin No
hazard. P TRF No. IECEN60065G TRF originator: ASTABEAB
11. Page 11 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause I Requirement - Test I Result - Remark I Verdict p IA p ~/A
p 9.1.4 Terminal devices tested with 1 mm x 20 mm test pin (10 N);
test probe D of IEC 61032 No live parts can be touched through
terminals. P Terminal devices tested with 1 mm x 100 mm straight
wire (1 N); test probe D of IEC 61032 No hazard. P 9.1.5 Pre-set
controls tested with 2.5 mm x 100 mm test pin (10 N); test probe C
of IEC 61032 No pre-set controls used. N/A 9.1.6 No shock hazard
due to stored charge on withdrawal of the mains plug; voltage (V)
after 2 s ................... : 16.7V after 2s. P If C is not
greater than 0,1 IJF no test needed N/A 9.1.7 a) Enclosure
sufficiently resistant to external force P Test probe 11 of IEC
61032 for 10 s (50 N) No damaged, No hazard P b) Test hook of fig.
4 for 10 s (20 N) No damaged, No hazard P c) 30 mm diameter test
tool for 5 s (100 or 250 N) 100N applied, no damaged, No hazards. P
9.2 No hazard after removing a cover by hand No protective cover.
N/A 10 INSULATION REQUIREMENTS P 10.1 Insulation resistance (MO) at
least 2 MO min. after surge test for basic and 4 MO min. for
reinforced insulation
.................................................................:
- Surge test with 50 discharges at a maximum rate of 12/min from a
1 nF capacitor charged to 10 kV performed. Measured greater than 4
MO between mains supply terminals to antenna terminals. P 10.2
Humidity treatment 48 h or 120 h ............................ At
93% R.H., 120hrs, 40C P 10.3 Insulation resistance and dielectric
strength between mains teminals . (see appended table) P Insulation
Resistance and dielectric strength across BASIC or SUPPLEMENTARY
insulation (Class 1) (see appended table) P Insulation resistance
and dielectric strength across REINFORCED insulation (Class II) N/A
1 FAULT CONDITIONS P 1.1 No shock hazard under fault condition No
electric shock during fault operation. P 11 2 Heating under fault
condition P No hazard from softening solder No solder point become
soft. P Flames extinguish within 10 seconds No flames during fault
test P T F No. IECEN60065G TRF originator: ASTABEAB
12. Page 12 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test tResult - Remark I Verdict Soldered
terminations not used as protective mechanism P 11.2.1 Measurement
of temperature rises (see appended table) P 11.2.2 Temperature rise
of accessible parts (see appended table) P 11.2.3 Temperature rise
of parts, other than windings, providing electrical insulation (see
appended table) P Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for max. 5min N/A a)
Temperature rise of printed circuit boards (PCB) to 20.1.3,
exceeding the limits of table 3 by not more than 100 K for an area
not greater than 2 cm2 N/A b) Temperature rise of printed circuit
boards (PCB) to 20.1 .3 up to 300 K for an area not greater than 2
cm2 for a maximum of 5 min N/A Meets all the special conditions if
conductors on printed circuit boards are interrupted Traces on the
PCB were not interrupted. N/A Class I protective earthing
maintained The protective earthing was maintained during all fault
conditions tests. P 11.2.4 Temperature rise of parts acting as a
support or mechanical barrier (see appended table) P 11.2.5
Temperature rise of windings (see appended table) P 11 .2.6
Temperature rise of parts not subject to the limits of 11 .2.1 to
11.2.5 (see appended table) P 12 MECHANICAL STRENGTH P , 12.1.1
Bump test where mass>7 kg Apparatus with max. mass P 10.91 kg.
After the test, the apparatus was no damage in the sense of this
standard. 12.1.2 Vibration test No damaged, No hazard P 12.1.3
Impact hammer test No damaged, No hazard P Steel ball test No
damaged, No hazard. P 12.1.4 Drop test for portable apparatus where
mass < 7 kg Not a portable apparatus. N/A 12.1 .5 Thermoplastic
enclosures strain relief test P 12.2 Fixing of knobs, push buttons,
keys and levers No such part. N/A 12.3 Remote controls with
hazardous live parts No hazardous voltage in the N/A remote
control. 12.4 Drawers (pull test 50 N, 10 s) No drawer N/A TRF No.
IECEN60065G TRF originator: ASTABEAB
13. 06 Page 130f112 Report No. : CEPREI1007CB0506 IEC/EN 60065
Clause , Requirement - Test IResult - Remark , Verdict 'A A p p p p
p p p P N/A P N/A N/A N/A 12.5 Antenna coaxial sockets providing
isolation No antenna coaxial socket N/A 12.6 Telescoping or rod
antennas construction N/A 12.6.1 Telescoping or rod antennas
securement N/A 13 CLEARANCE AND CREEPAGE DISTANCES P 13.1
Clearances in accordance with 13.3 See clause 13.3. P Creepage
distances in accordance with 13.4 See clause 13.4. P 13.2
Determination of operating voltage The rms and the peak voltage of
the appliance is mains voltage 240V max. The unit was connected to
a 240V TN power system. See clause 13.3 and 13.4. P 13.3 Clearances
See below. P 13.3.1 General See appended table 13. P 13.3.2
Circuits conductively connected to the mains comply with table 8
anc;l, where applicable, table 9 See appended table 13. P 13.3.3
Circuits not conductively connected to the mains comply with table
10 See appended table 13. P 13.3.4 Measurement of transient
voltages N/A 134 Creepage distances See appended table 13. P
Creepage distances greater than table 11 minima Considered. P 13.5
Printed boards Not applied for. N/A 13.5.1 Clearances and creepage
distances between conductors on printed circuit boards, one of
which may be conductively connected to the mains, as in fig. 10
Same as above N/A 35.2 Type B coated printed circuit boards
complying with IEC 60664-3 (basic insulation only) Same as above
N/A 13.6 I I Conductive parts along uncemented joints clearances
and creepage distances comply with 13.3 and 13.4 Conductive parts
along reliably cemented joints comply with 8.8 No such components.
Same as above N/A N/A Temperature cycle test and dielectric
strength test N/A 137 I Enclosed, enveloped or hermetically sealed
parts: not conductively connected to the mains: clearances and
creepage distances as in table 12 Not such a construction. N/A
113.8 Parts filled with insulating compound, meeting the
requirements of 8.8 Nosuchcomponen~. N/A TABEAB T ~F No.
IECEN60065G TRF originator: ASTABEAB
14. Page 14 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement Test IResult - Remark I Verdict 14 COMPONENTS
14.1 Resistors a) Resistors between hazardous live parts and
accessible metal parts b) Resistors, other than between hazardous
live parts and accessible parts Resistors separately approved
.................. ........... .. . 14.2 Capacitors and RC units
Capacitors separately approved 14.2.1 Y capacitors tested to IEC
60384-14, 2 nd edition .... : 14.2.2 X capacitors tested to IEC
60384-14, 2 nd edition ..... 14.2.3 Capacitors operating at mains
frequency but not connected to the mains: tests for X2
...................... : 14.2.5 Capacitors with volume exceeding
1750 mm3 , where short-circuit current exceeds 0,2 A: compliance
with IEC60384-1, 4.38 category B or better ., ..................
Capacitors with volume exceeding 1750 mm3 , mounted closer to a
potential ignition source than table 5 permits: compliance with IEC
60 384-1,4.38 category B or better
.................................................: Shielded by a
barrier acc. to 20.1.4/ table 21 or metal , ...., .., ..,
....................., ...., ................,
........................... . 14.3 Inductors and windings Comply
with IEC 61558-1 , IEC 61558-2 (as relevant) and clause 20.1.4
14.3.1 Transformers and inductors marked with manufacturer's name
and type ............................... : Transformers and
inductors separately approved .. : 14.3.2 General Insulation
material complies with clause 20.1.4 14.3.3 Constructional
requirements 14.3.3.1 Clearances and creepage distances comply with
clause 13 P N/A No such components. N/A Bleeder resistor (R 1, R2,
P R3, R4) N/A P Yes. See appended table P 14 for details. All
sources of Y1 capacitors P ( CY1, CY2, CY3, CY4 ) are approved
according to IEC60384-14, X2: (CX1 , CX2) is P approved according
to IEC60384-14. No such components. N/A Such capacitors with
metallic enclosure P Such capacitors with P metallic enclosure N/A
See below P N/A Trade mark and type name P listed on it (see
appended table 14) Tested in appliance. P p P p - =-' See appended
table 13.1 P TRF No. IECEN60065G TRF originator: ASTABEAB
15. Page 15 of 112 Report No.: CEPREI1 007CB0506 IP ~/A ~/A P
~/A P P p III P N/A P 1.1 p i:' 1'1 N/A P N/A P P P P [I PII' P
STABEAB W IEC/EN 60065 Clause lRequirement - Test IResult - Remark
1 Verdict 14.3.3.2 Transformers meet the constructional
requirements Compliance. P 14.3.4.1 Class II transformers have
adequate separation Double and reinforced P between hazardous live
parts and accessible parts insulation between primary (double or
reinforced insulation) and secondary windings. Coil formers and
partition walls> 0,4 mm Min. 0.6 mm P 14.3.4.2 Class I
transformers, with basic insulation and Class II N/A protective
screening only if all 7 conditions of 14.3.4.2 are met 14.3.4.3
Separating transformers with at least basic insulation N/A 14.3.5.1
Class II transformers have adequate inSUlation Double/Reinforced P
between hazardous live parts and accessible parts insulation
(double or reinforced insulation) Coil formers and partition
walls> 0,4 mm Min. 0.6 mm P 14.3.5.2 Class I transformers have
adequate insulation Class II N/A between hazardous live parts and
accessible conductive parts or those conductive parts or protective
screens connected to a protective earth terminal Winding wires
cennected to protective earth have N/A adequate current-carrying
capacity 14.4 High voltage components No High voltage N/A
components High-voltage components and assemblies: U > 4 kV N/A
(peak) separately approved I Component meets category V-1 of IEC
60707 N/A 4 4.1 High voltage transformers and multipliers tested as
N/A part of the submission 44 2 High voltage assemblies and other
parts tested as part N/A of the submission . ';! 5 Protective
devices See below. P '. Protective devices used within their
ratings See 14.5.2.1. P . External clearances and creepage
distances meet P requirement of clause 13 for the voltage across
the I device when opened t. - 1 a) thermal cut-outs separately
approved No thermal cut-outs N/A b) Thermal cut-outs tested as part
of the submission N/A . 2 a) Thermal links separately approved No
thermal links used. N/A b) Thermal links tested as part of the
submission N/A ... ~ 5 3 Thermal devices re-settable by soldering
N/A '0 IECEN60065G TRF originator: ASTABEAB
16. Page 16 of 112 Report No. : CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test IResult - Remark I Verdict 14.5.2.1
Fuse-links in the mains circuit according to IEC 60127 Fuse that
directly connected to the mains is approved component according to
IEC 60127. See appended table 14 for details. P 14.5.2.2 Correct
marking of fuse-links adjacent to holder . ... Fuse marking on PCB
near F1: T5.0ALl250Vac P 14.5.2.3 Not possible to connect fuses in
parallel ................ No parallel P 14.5.2.4 Not possible to
touch hazardous live parts when replacing fuse-links without the
use of a tool ........ .. Tools are required P 14.5.3 PTC-S
thermistors comply with IEC 60730-1 No PTC-S thermistors N/A PTC-S
devices (15 W) category V-1 or better N/A 14.5.4 Circuit protectors
have adequate breaking capacity and their position is correctly
marked N/A 14.6 Switches Approved mains switch used. See appended
table 14 for details. P 14.6.1 a) Separate testing to IEC 61058
including: 10 000 operations Normal pollution suitability
Resistance to heat and fire level 3 Certificated mains switch
provided comply with requirements and characteristics; See appended
table 14 for details. P and Make and break speed independent of
speed of actuation V-O compliance with annex G, G.1.1 14.6.1 b)
Tested in the apparatus: N/A Switch controlling> 0.2A ~ith open
contact voltage> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-O in annex G, G.1.1 N/A Switch controlling> 0.2A
with open contact voltage < 35 V (peak)/24 V dc complying with
14.6.3 and v-o in annexG, G.1 .1 N/A Switch controlling < 0.2A
with open contact voltage> 35 V (peak)/24 V dc complying with
14.6.4 and V-O in annexG, G.1.1 N/A 14.6.2 Switch tested to 14.6.1
b) constructed to IEC 61058-1 subclause 131 and has making/breaking
action independent of speed of actuation N/A 14.6.3 Switch tested
to 14.6.1 b) compliant with IEC 61058-1 subclause 16.2.2 d) and m)
not attaining excessive temperatures in use N/A TRF No. IECEN60065G
TRF originator: ASTABEAB
17. Page 17 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
~B0506 ~rdict p p p P N/A N/A N/A P ill P N/A N/A N/A N/A N/A N/A
14.6.4 Clause Switch tested to 14.6.1 b) has adequate dielectric
Requirement - Test Result - Remark N/A Verdict strength 14.6.5
Mains switch controlling mains socket outlets No socket outlets N/A
additional tests to IEC 60058-1 Socket outlet current marking
correct N/A 147 Safety interlocks No safety interlocks N/A Safety
interlocks to 2.8 of IEC 60950 N/A , 4.8 Voltage setting devices
and the like No voltage setting devices N/A Voltage setting device
not likely to be changed N/A accidentally 14.9 Motors No motors N/A
14 9 1 Endurance test on motors N/A Motor start test N/A Dielectric
strength test N/A I 492 Not adversely affected by oil or grease
etc. N/A 14.9.3 Protection against moving parts N/A 114 9.4 Motors
with phase-shifting capacitors, three-phase N/A B.10 of IEC 60950,
Annex B motors and series motors meet clause. B.8, B.9 and 14 10
Batteries No batteries N/A 4.1 .1 flammable gases Batteries mounted
with no risk of accumulation of N/A '4 10.2 No possibility of
recharging non-rechargeable batteries N/A '.1 0 3 Recharging
currents and times within manufacturers N/A limits . N/ALithium
batteries discharge and reverse currents within i the manufacturers
limits N/A .4 Battery mould stress relief ".L! "1 N/ABattery drop
test5 f I i ~ ... POptocouplers(IC3,IC4,IC5)Optocouplers separately
approved. See appended table 14 for details. Optocouplers comply
with CI. 8 POptocouplers(IC3,IC4,IC5) separately approved. Internal
and external dimensions to 13.1. or POptocouplers(IC3,IC4,IC5)
separately approved.~ alternatively 13.6 Uointed insulation) . ,
PCertified component used.Surge suppression varistors- - See
appended table 14. I:, 'STABEAB IECEN60065G TRF originator:
ASTABEAB L.!J
18. Page 180f112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test IResult - Remark I Verdict Comply with
IEC 61051-2 Certified component used. P Not connected between mains
and accessible parts except for earthed parts of permanently
connected apparatus P Complies with the current pulse, fire hazard
and thermal stress requirements of 14.12 P 15 TERMINALS P 15.1.1
Mains plug, appliance inlet, interconnection couplers and mains
socket-outlet meet the appropriate standard Approved appliance
inlet used. See appended table 14 for details. P Overloading of
plugs or appliance inlets prevented if the apparatus has mains
socket outlets No mains socket outlet provided. N/A Overloading of
internal wiring prevented if the apparatus has mains socket outlets
No mains socket outlet provided. N/A 15.1 .2 Connectors for
antenna, earth, audio, video or data: P No risk of insertion in
mains socket-outlets . Signal input/output connectors are so
designed that insertion into mains socket-outlet or appliance
coupler is unlikely to occur. P No risk of insertion into audio or
video: outlets marked with the symbol of 5.2 No such symbol of 5.2
N/A 15.1.3 Output terminals of a.c. adaptors or similar devices not
compatible with household mains socket-outlets No output terminals
of a.c adaptors or similar devices N/A 15.2 Provision for
protective earthing P Accessible conductive parts of Class I
equipment reliably connected to earth terminal, within equipment
Accessible conductive parts are reliably earthed. P Protective
earth conductors correctly coloured N Equipment with non-detachable
mains cord provided with separate protective earth terminal near
mains input P Protective earth terminal resistant to corrosion p
Earth resistance test: < 0,1 n at 25 A .,..................:
Test from earth pin of AC inlet to metal chassis is 32mO at 25A
within 1 minute. P 15.3 Terminals for external flexible cords and
for permanent connection to the mains supply N/A 15.3.1 15.3.2
Adequate terminals for connection of permanent wiring Reliable
connection of non-detachable cords: N/A N/A TRF originator:
ASTABEABTRF No. IECEN60065G
19. CB0506 Page 190f112 Report No.: CEPREI1007CB0506 IEC/EN
60065 ClaJse Requirement - Test Result - Remark Verdict p p p p P
N/A N/A P P N/A N/A P P N P P P N/A N/A N/A ASTABEAB I I I 5 3.3
5.3.4 I I 5.35 I 5.3 6 15 37 ~ I . - 3 8 . : 3.9 I 5.! .::; 1 r::;
-2 - ~ --... Not soldered to conductors of a printed circuit board
Adequate clearances and creepage distances between connections
should a wire break away Wire secured by additional means to the
conductor Screws and nuts clamping conductors have adequate
threads: ISO 261, ISO 262 or similar Soldered conductors wrapped
around terminal prior to soldering or held in place by additional
means Clamping of conductor and insulation if not soldered or held
by screws Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of the
equipment Terminals to 15.3.3 have sizes required by table 16
Terminals clamp conductors between metal and have adequate pressure
Terminals designed to avoid conductor slipping out when tightened
or loosened Terminals adequately fixed to avoid loosening when the
clamping is tightened or loosened and stress on internal wiring is
avoided Terminals carrying a current more than 0,2 A: contact
pressure not transmitted by insulating material except ceramic
Termination of non-detachable cords: wires terminated near to each
other Terminals located and shielded: test with 8 mm strand Devices
forming a pqrt of the mains plug No undue strain on mains
socket-outlets Device complies with standard for dimensions of
mains plugs Device has adequate mechanical strength (tests a,b,c)
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A P N/A N/A N/ANot direct
plug-in equipment. N/A N/A N/A IEXTERNAL FLEXIBLE CORDS N/A
IECEN60065G TRF originator: ASTABEAB
20. Page 20 of 112 Report No. CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test I Result - Remark I Verdict 16.1 Mains
cords sheathed type, complying with IEC 60227 for PVC or IEC 60245
for synthetic rubber cords ... : A separately approval/certified
power cord that incorporates plug which complies with the special
national requirements should be provided with this unit when
marketing in the specified countries. N/A Non-detachable cords for
Class I have green/yellow core for protective earth N/A 16.2 Mains
cords conductors have adequate cross- sectional area for rated
current consumption of the equipment N/A 16.3 a) Flexible cords not
complying with 16.1, used for interconnections between separate
units of equipment used in combination and carrying hazardous live
voltages, have adequate dielectric strength No interconnection
cords N/A b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2) N/A 16.4
Flexible cords used foe connection between equipment have adequate
cross-sectional areas to avoid temperature rise under normal and
fault conditions N/A 16.5 Adequate strain relief on external
flexible cords N/A Not possible to push cord back into equipment
N/A Strain relief device unlikely to damage flexible cord N/A For
mains cords of Class I equipment, hazardous live conductors become
taut before earth conductor N/A 16.6 Apertures for external
flexible cord: no risk of damage to the cord during assemqly or
movement in use N/A 16.7 Transportable musical instruments and
amplifiers fitted with detachable cord set with appliance inlet to
IEC 60320-1 N/A Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of stowage to
protect the cord N/A 17 ELECTRICAL CONNECTIONS AND MECHANICAL
FIXINGS P 17.1 Torque test to table 20: See below p - screws into
metal: 5 times 1.2 Nm P - screws into non-metallic material: 10
times 0.5 Nm p 17.2 Correct introduction into female threads in
non-metallic material Correct introduction provided. P TRF
originator: ASTABEABTRF No. IECEN60065G
21. iii II ~7CB0506 Page 21 of 112 Report No.: CEPREI1007CB0506
IEC/EN 60065 Requirement - Test Result - Remark VerdictVerdict I ~
STABILITY AND MECHANICAL HAZARDS P , Mass of the equipment
exceeding 7 kg .................. : 10.91 kg. PI I Apparatus
intended to be fastened in place - suitable N/A instructions ,3
N/ANo captive screw used.Cover fixing screws: captiveN/A
PNon-captive fixing screws: no hazard when replaced Tested with
screw whose by a screw whose length is 10 times its diameter length
is 10 times its diameter and found no shock hazard. N/ANo loosening
of conductive parts carrying a current > 0,2 A ~ - 5 1-- .
PContact pressure not transmitted through plastic other Contact
pressure is not N/A than ceramic for connections carrying a current
transmitted through > 0,2 A insulating material. I. Ir , 6
N/AN/A Stranded conductors of flexible supply cords carrying a No
screw terminal l current> 0,2 A with screw terminals not
consolidated by solder N/AN/A 7 7 Cover fixing devices other than
screws have adequate strength and their positioning is unambiguous
1,1: -7 N/AFixing devices for detachable legs or stands provided -
9 PInternal pluggable connections, affecting safety, 2N force
applied onN/A unlikely to become disconnected primary and secondary
connectors. No hazard. N/A N/AMECHANICAL STRENGTH OF PICTURE TUBES
AND PROTECTION AGAINST , THE EFFECTS OF IMPLOSIONN/A N/APicture
tube separately approved to IEC 61965:N/A I Picture tube separately
approved to 18.1 ................ N/AN/A N/APicture tubes> 16 cm
intrinsically protected-N/A IN/A N/A II 11-:2 lili '7 ... 4 - N/A -
':""2 III1 .:-3 p - ~ p1,1 p Non-intrinsically protected tubes>
16 cm used with protective screen Protective film as p,art of
implosion protection: edges covered by enclosure Intrinsically
protected tubes: tests on 12 samples Samples subject to ageing: 6
Samples subject to implosion test: 6 Samples subject to mechanical
strength test (steel ball): 6 Non-intrinsically protected tubes
tested to 18.3 N/A N/A N/A N/A N/A N/A N/A p p II,' IECEN60065G TRF
originator: ASTABEABSTABEAB L.JJ II
22. '=11007CB0506 "":":!:i..a se I Requirement - Test 9 1 Test
on a plane, inclined at 10 to 100 N force applied vertically dCM
9.3 100 N force, or 13% of weight. a c.:' point of least stability.
19.4 Edges or corners not hazardo 19.5 Glass surfaces
(exc.laminated exceeding 0,1 m2 or maxim C:::E:S:::: pass the test
of 19.5.1 19.6 Wall or ceiling mountings a_= ~ Verdict p p p P N/A
N/A ';:~::r:::J:::'=-::S are _ PCB with V-O - ignition source and e
closure exceed , es specified in e 21 . er. p20 RESISTANCE TO FIRE
p20.1 N/A p p20.1.1 N/A20.1.2 N/A20.1.3 p p20.1.4 N/A TRF No.
IECEN60065G TRF originator: ASTABEA
23. Page 23 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Requirement - Test Result - Remark Verdict ~CB0506 II Verdict p p P
I' P N/A ,II, N/A 1' 1' P P N/A P P N/A N/A P P N/A ~ ASTABEAB 2 2
Apparatus with voltages >4kV under normal operating conditions
and distances to the enclosure exceed those specified Table 21,
flammability classification HB40 or better is required for the
enclosure. Fire enclosure Not exceeded 4kV N/A N/A .2.1 Potential
ignition sources with open circuit voltage > 4 kV (peak) a.c. or
d.c. contained in a fire enclosure to V-1 N/A 22 I 2 .23 Internal
fire enclosures with openings not exceeding 1 mm in width and with
openings for wires completely filled Requirements of 20.2.1 and
20.2.2 met by an internal fire enclosure N/A N/A I N/AAPPENDIX A,
ADDITIONAL REQUIREMENTS FOR APPARATUS WITH PROTECTION AGAINST
SPlASHING WATER - - . N/Aj) Marked with IPX4 (IEC 60529), 5.4.1 a)
does not applyI I ~ N/AEnclosure prov.ides protection against
splashing water _ . ~ - ~" 2 - N/AHumidity treatment carried out
for 7 days :i APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS N/A Complies with IEC 62151 clause 1 N/A
Complies with IEC 62151 clause 2 N/A Complies with IEC 62151 clause
3 but with 3.5.4 modified to 2.4.10 of this standard N/A Complies
with IEC' 62151 clause 4 but with 4.1.2, 4.1.3 and 4.2.1.2 modified
in accordance with annex B of this standard N/A II II ~I II II
Complies with IEC 62151 cause 5 but with 5.3.1 modified in
accordance with annex B of this standard Complies with IEC 62151
clause 6 Complies with IEC 62151 clause 7 Complies with IEC 62151
annex A, Band C N/A N/A N/A N/A i~ :-:.- APPENDIX L, ADDITIONAL
REQUIREMENTS FOR ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC
PURPOSES. IMarking and Instructions I N/A N/A - =60065G TRF
originator: ASTABEAB
24. Page 24 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequtrement - Test JResult - Remark J Verdict L9.1.1
Terminals to connection to synchroniser not N/A HAZARDOUS LIVE
L7.1.5& Lithium batteries meet permissible temp rise in Table
N/A L11 .2.6 3 , unless comply with 6.3.2 of IEC 60086-4 L14.6.6
Mains switch characteristics appropriate to its N/A function under
normal conditions TRF No. IECEN60065G TRF originator: ASTABEAB
25. jeS0506 ferdict Page 25 of 112 Report No.: CEPREI1007CB0506
IEC/EN 60065 Requirement - Test Result - Remark Verdict NfA fA r fA
, ' I 1 ., . TABLE: temperature rise measurements P Power
consumption in the OFF/Stand-by OW/0.78W P Position of the
functional switch (W) .......................: - - ~ _'= 'dUI19
conditions --,; ;: aratus was mounted as follows: - ....""'" o ed
in accordance with the instructions for use provided by the
manufacturer. - ....e apparatus having a supply voltage range of
100-240 V, was tested at 0.9 times the lower limit and . es the
upper limit of the supply voltage range. - "'e frequency of the
mains supply that the apparatus was connected to during tests was
50/60Hz. ' II Un (V) In (A) Pn (W) I Pout (W)I . r aximum
non-clipped output power: AV mode , gO/50Hz 1.189 106.8 1.58 I
gO/60Hz 1.189 106.4 1.58 OO/50Hz 1.070 104.8 1.58 I 00/60Hz 1.058
104.7 1.58 240/50Hz 0.463 104.0 1.580 24 160Hz 0.467 103.7 1.58
64/50Hz 0.431 103.7 1.58 I 64/60Hz 0.439 103.6 1.58 on-clipped
output power: AV mode 90/50Hz 1.287 115.2 13.0 264/50Hz 0.472 113.6
13.0 II Loudspeaker impedance (0) . ............... , ........
........ 40 - :1 Several loudspeaker systems - 1 Marking of
loudspeaker terminals - ~. :r=~ int: dT (K) dT (K) Limit dT (K) 1
90V50Hz 264V/50Hz - ~: - -. '" ertor) 43.2 43.0 75- :::2 - = .ear
T1 01) 39.9 39.8 85 .~ - 36.6 36.4 70- :~! - . 34.1 35.6- - - .':s
52.1 52.1 - ;:s 47.7 47.8 - STABEAB 60065G TRF originator ASTABE
8
26. age 26 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IReq ire en! es 1Result - Remark I Verdict 07. Switch 4.3
3.0 50 08. AC inlet near L 4.1 3.4 60 09. Primary lead wire 10.6
9.4 60 10. CON1 15.4 12.0 50 11 . LF2 Bobbin 22.6 15.4 75 12. BD1
42.3 28.7 - 13.01 33.6 25.1 - 14. HS1(Near 01) 36.4 25.7 - 1-5. L1
Bobbion 41.4 34.1 75 16. C7 19.4 17.3 70 17. IC3 29.4 29.0 - 18. T1
Core 40.8 40.3 75 19. T1 Coil 49.6 47.4 65 20. PCB(Near T1) 10.0
18.1 85 21 . T2 Core 26.8 27.0 75 " 22. T2 Coil 35.4 36.4 65 23. U8
31.9 31 .3 - 24. U1 31 .6 29.6 - 25. U4 21 .1 20.5 - 26. Mains Cord
2.5 2.0 60 27. Encolsure 17.8 15.6 60 28. Ambient 24.3 24.4 -
Winding temperature rise measurements Ambient temperature t1 tC)
............................... .... - Ambient temperature t2 tc)
., ..... ............... ............ - Temperature rise dT of
winding: R1 (0) R2 (0) dT (K) Limit dT (K) Insulation class 7.2
ITABLE: softening temperature of thermoplastics I p Temperature T
of part T - normal condi tions (0c) T - fault condi tions (0c) T
softening (C) CON1 40.7 56.4 > 150 I II TRF No. IECEN60065G TRF
originator: ASTABEAB
27. 0 2 Page 27 of 112 Report No.: CEPREI1007CB0506CB0506 " p
~ftening 0c) ~ 150 II' ~erdict p p 6 uI jl IT 5 ro ! - ~ "'0 ~ 1-
Ilr - ~ ~.o - ,I: - - class IEC/EN 60065 IRequirement - Test
IResult - Remark I Verdict -4 " I TABLE insulation resistance
measurements p - Ip R (MO) - Required R (MO) es with primary Fuse
disconnected (Basic insulation) -- - esistance R between: > 250
2 - es and terminals (Reinforced insulation) es and metal enclosure
(Basic insulation) 53.1 449.6 ' ...:-=:. er T1 primary and
secondary (Reinforced insulation) 4> 250- -=:-.s~er T1 primary
and core (Basic insulation) 2>250 -"a -,="'UII lIer T1 secondary
and core (Basic insulation) 2> 250 ""a.- -~ 4er T2 primary and
secondary (Reinforced insulation) > 250I I -~: er T2 primary and
core (Basic insulation) 2> 250 . 2~ ---; er T2 secondary and
core (Basic insulation) >250 Jo 4[- 'f er i sulation tape
wrapped on transformer T1, T2 > 250 p - ITABLE: electric$trength
measurements I ~ Test voltage (V) Breakdown IIIL:.. es with primary
Fuse disconnected (Basic insulation) - ~e applied oetween: ~ No -
e.s and metal enclosure (Basic insulation) 1500Vac 1500Vac No No
It;.~~-> 'Ier T1 primary and secondary (Reinforced insulation)
as and terminals (Reinforced insulation) 3000Vac, ~---.s r 3000Vac
No ,II!_~~LJ .cr T1 primary and core (Basic insulation) 1500Vac No
:'L~~-;;" l, er T1 secondary and core (Basic insulation) 1500Vac No
,It=-.,.= c.:: er T2 primary and secondary (Reinforced insulation)
3000Vac No i- . 1500VacII.-';~
28. Page 28 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test IResult - Remark l Verdict T101 output,
short-circuit, 264Vac, 5min, 1= 0.09A, - - Unit shutdown
immediately, No hazards. C201, short-circuit, 264Vac, 1s, 1= 0.09A,
- - Unit shutdown immediately, No hazards. OS5, short-circuit,
264Vac, 10min, 1= 0.088A-0.139A - - Unit shutdown immediately, No
hazards. CS5, short-circuit, 264Vac, Bmin, 1= 0.OBBA-0.112A - -
Unit shutdown immediately, No hazards. OS4 short-circuit, 264Vac,
15min, 1=0.088A - - Unit shutdown immediately, No hazards. OS2
short-circuit, 264Vac, 10min, 1=0.090A - - Unit shutdown
immediately, No hazards. CS7 short-circuit, 264Vac, 10min, 1=0.OB8A
- - Unit shutdown immediately, No hazards. IC5 pin1 to 2,
short-circuit, 264Vac, 7!'lins, 1= 0.OB8A - - Unit shutdown
immediately, no damaged, no hazards. IC5 pin3 to 4, short-circuit,
264Vac, 15mins, 1= 0.08BA - - Unit shutdown immediately, no
damaged, no hazards. IC4 pin1 to 2, short-circuit, 264Vac, 15mins,
1= 0.088A - - Unit shutdown immediately, no damaged, no hazards.
IC4 pin3 to 4, short-circuit, 264Vac, 7mins, 1= 0.OB8A - - Unit
shutdown immediately, no damaged, no hazards. IC3 pin1 to 2,
short-circuit, 264Vac, 10mins, 1= O.OBBA - - , Unit shutdown
immediately, no damaged, no hazards. IC3 pin3 to 4, short-circuit,
264Vac, 10mins, 1= O.OBBA - - Unit shutdown immediately, no
damaged, no hazards. C20 short-circuit, 264Vac, 1s, I=OA - - Fuse
opened immediately, No hazards. B01 "+" to "-", short-circuit,
264Vac, 1s, 1= 10.5A-OA - - Fuse opened immediately, No hazards.
B01 "+" to "-", short-circuit, 90Vac, 1s, 1= 10.5A-OA - - Fuse
opened immediately, No hazards. C7 short-circuit, 264Vac, 1s, 1=
10.5A-OA - - Fuse opened immediately, No hazards. TRF No.
IECEN60065G TRF originator: ASTABEAB
29. Page 29 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Requirement - Test Result - Remark Verdict B0506 Verdict ~- -:-c'
cuit, 90Vac, 1s, 1= 10.5A-OA ed immediately, No hazards.
rt-circuit, 90Vac, 1s, 1= 10.5A-OA ed immediately, No hazards. ax
non-clipped output power, 264V, 1hrs, 1= 0.472A al operation, no
extremely high temperature, no hazards. ax. non-clipped output
power, 90V, 1hrs, 1= 0.1.287A al operation, no extremely high
temperature, no hazards. ocked, 264V, 4hrs, 1= 0.431A 31operation,
no damage, no hazards. ked, 90V, 4.0hrs, 1= 1.189A peration, no
damage, no hazards. -:-circuit, 264Vac, 30min, 1=0.439A ration, no
extremely high temperature, no hazards. ding temperature rise
measurements bient temperature t1 (0C)
............................... .. .. : - blent temperature t2 (0C)
.. ................................. : - -ao'e working voltage
measurement T1 coil, dT =53.0K T1 core, dT =60.8K T2 coil, dT
=42.3K T2 coil, dT =50.5K Ambient = 24.4 "C. T1 coil, dT =53.9K T1
core, dT =62.4K T2 coil, dT =42.8K T2 coil, dT =51.1 K Ambient =
24.5 "C. T1, T2 coil limit dT= 135K, T1, T2 core limited= 140K. T1
, T2 coil limit dT= 135K, T1, T2 core limited= 140K. p 5G TRF
originator: ASTABEABSTABEAB
34. Page 34 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause IRequirement - Test IResult - Remark I Verdict Component I,
Manufacturer/ I trademark II Type/model I Value / rating I Standard
Approval/ Reference PCB Shunde Junda Electronic Co. ,Ltd. UL:JD-D
COC:ZD-95(G)F 1.6mm v-o UL UL:E173873 COC0400101119 6 -All. HuiZhou
Gospeed Technologies CO.,Ltd UL:JF-D COC :ZD-95(G)F V-O, 130'C UL
UL: E309386 COC0900103671 2 -All. GO SPEED PCB CO UL GS-02 V-O,
130'C UL UL: E190219 Varistor ( VR1) Thinking Electronic industrial
CO. ,LTD TVR10511 510V IEC/EN 61051-2 UL :E173642 VDE: 005944
COC0300100765 4 Thermal Resistance (TH1) Thinking Electronic
industrial CO., LTO SCK-037 3 Q,7A UL UL:E138827 TUV:R 50050155
COC0500101199 3 Mylar film JIANGSU YUXING FILM TECHNOLOGY CO LTD
6023 VTM-2,105 'C ,Thickness min.OAmm UL UL:E212271 -All. MIANYANG
LONGHUA FILM CO LTD PC-860-60B VTM-2,105 'C ,Thickness min.OAmm UL
UL:E254551 Heat-shrink tube RUIXIN ELECTRONICS INSULATION FACTORY
Rx-l VW-1 , 600V, 125 'C Inductor (LF2,LF3) SHENZHEN JlNG YE
MAGNETISM ELECTRONIC CO.,LTD LKL-I OI 9mH min / / -All. SHENZHEN
YIXfNWENDA ELECTRONICS CO.,LTD LKL-IOI 9mH min / / WIRE SHENZHEN
CHENGWEI INDUSTRIAL CO., LTD OR OTHER SOURCE. 2UEW 130'C UL
UL:E227475 TRF No. IECEN60065G TRF originator: ASTABEAB
35. 07CB0506 Page 35 of 112 Report No,: CEPREI1 007CB0506
IEC/EN 60065 _ irement - Test Result - Remark Verdict ~proval/
(ference 73873 :400101119 ~09386 ~00103671 [190219 :173642 005944
P300100765 ~1 38827 R 50050155 0500101199 E212271 254551 ~22747S II
f ASTABEAB II TRF originator: ASTABEAB _.....-,._T_- =_. I Ti - I l
- Manufacturer/ trademark A0. l lA PECI/L WIRE fFR (XINYU) CO..LTD
IH. XG CHEUNG PETROCHEMICA L LTD ujiang Taihu In>u!aling
Material CO.,Ltd HENZHEN YIXINWENDA E ECTRONICS CO., LTD S E ZHEN
JING YE MAGNETISM ELECTRONIC CO ,LTD HENGZHEN ENGTENGDA ELECTRONICS
CO LTD C:-tANG CHUN vTICS CO _TO ~ H EN ZHEN CITY CHENGWEI I USTRY
CO , T AN JIA SPECIAL WIRE =R (XINYU) C .L D v GYUAN =LECTRONICS S
ENZHEN)CO - ~ GJIANG J-lUA :; ESSURE :: SITIVE GLUE TD YU - E
GDAFENG F . TRIC I '"TERIAL_ _TO Type/model Value / rating Standard
Approval/ Reference UEWf3 130'C UL UL: E317291 8S62/C lSS 'C UL UL:
E2001S4 130'C UL T4260a UL:E228349 LKT-114B Class B,130'C IEC
60065:2005 Tested with appliance LKT-114B Class S,130'C IEC
60065:2005 Tested with appliance LKT-114B Class S,130'C IEC
60065:2005 Tested with appliance T375J 150'C UL UL: E59481 UL 2UEW
130'C UL:E227475 UL UEWB 130'C UL: E317291 UL TLW-S 130'C
UL:E249037 UL PZ-48 130'C UL:E165111 UL SDF-317 130'C UL:
E317896
36. Page 36 of 112 Report No.: CEPREI1007CB0506 IEC/EN 60065
Clause I Requirement - Test IResult - Remark I Verdict Component
Manufacturer/ trademark Type/model Value / rating Standard
Approvall Reference VARNISH HANG CHEUNG PETROCHEMICA L LTD 8562/C
155C UL UL: E200154 WU JIANG TAIHU INSULATING MATERIAL CO LTD
T4260(a) 155C UL UL: E228349 TUBE CHANGYUAN ELECTRONICS (SHENZHEN)
CO , LTD CB-TI-S 130'C UL UL:E180908 EPOXY LlGU ELECTRONIC MATERIAL
DONGGUAN CO .,LTD LG9001 AlB(a) 130C UL UL E305307 Transformer (T2)
SHENZHEN YIXINWENDA ELECTRONICS CO ,LTD LKT-115 Class B,130'C IEC
60065:2005 Tested with appliance -Alt SHENZHEN JING YE MAGNETISM
ELECTRONIC CO.,LTD LKT- 115 Class B,130'C IEC 60065:2005 Tested
with appliance -Alt SHENGZHEN PENGTENGDA ELECTRONICS CO .LTD LKT-
115 Class B,130'C IEC 60065:2005 Tested with appliance Bobbin CHANG
CHUN PLASTICS CO LTD T375J 150'C UL UL: E59481 WIRE SHEN ZHEN CITY
CHENGWEI INDUSTRY CO LTD 2UEW 130'C UL UL:E227475 WAN JIA SPECIAL
WIRE MFR (XINYU) CO ., LTD UEWB 130'C UL UL: E317291 CHANGYUAN
ELECTRONICS (SHENZHEN) CO LTD TLW-B 130'C UL UL:E249037 TAPE
JINGJIANG YAHUA PRESSURE SENSITIVE GLUE CO LTD PZ-48 130'C UL
UL:E165111 TRF No. IECEN60065G TRF originator: ASTABEAB
37. Page 37 of 112 Report No. CE IEC/EN 60065 equirement - Test
IResult - Remark ~:0 7CB0506 Verdict pproval/ ~ference P00154 I!!
P28349 80908 ,I I f:,05307 [!!sted with !Eopliance 1~led with ~p
liance r,;sted with ~ pliance Fs9481 III D 2747S 1~3 17291 I: II
~49037 1,'1 f :1 ~ 1 65111 1,1 -.-.J~.~._ -=..,: Manufacturer/
trademark Type/model Value / rating Standard > ~ - - -1::-::,
..-.;-=. I I ,i XINYU SHENGDAFENG ELECTRIC MATERIAL CO .,LTD HANG
CHEUNG PETROCHEMICA L LTD SDF-317 8562/C 130C 155'C UL UL UL. E3'
-- UL: E2 _ - - WU JIANG TAIHU INSULATING MATERIAL CO LTD T4260(a)
15SC UL UL E2 - I I CHANGYUAN ELECTRONICS (SH ENZHEN) CO , LTD
CB-TI-S 130C UL ULE1 80903 I ~ lIGU ELECTRONIC MATERIAL DONGGUAN CO
.,LTD . LG9001A1B(a) 130C UL UL:E305307 . ~~, J .. ca es a mark
which assures the agreed level of surveillance [I 1;1 .. ASTABEAB
TRF originator: ASTABEAB H
38. Page 38 of 112 Report No.: CEPREI1007CB0506 --, lIational
Differences -Clause Requirement - Test Result - Remark Verdict
~----; APPENDIX GROUP DIFFERENCES according to CB Bulletin
l'Jo.112A, December 2006 P (IEC Publication 60065 7th edition +
Amendment 1) CONTENT Add the following annexes: Added. P S Annex ZA
(normative) Other international publications quoted in this
standard with the references of the relevant European publications
Annex ZB (normative) Special national conditions Annex ZC
(normative) A-deviations 3.1 Add the following indent at the end of
the list: Not portable audio N/A - exposure to excessive sound
pressures from equipment. ~ headphones or earphones. NOTE A new
method of measurement is described in EN 50332-1, Sound system
equipment: Headphones and earphones associated with portable audio
equipment - Maximum sound pressure level measurement methodology
and limit considerations - Part 1: General method for "one package
equipment", and in EN 50332-2, Sound system equipment: H'eadphones
and earphones associated with portable audio equipment- Maximum
sound pressure level measurement methodology and limit
considerations - Part 2: Guidelines to associate sets with
headphones coming from different manufacturers. 4.1.1 Replace the
text of the note by: Replaced . N/A NOTE For ROUTINE TEST reference
is made to EN 50333. 5.1.i) Add the following note: Added. P NOTE
For RATED POWER CONSUMPTION measurements of TVs reference is made
to EN 60107. 6.1 Replace the entire subclause by: Replaced. P
Apparatus including a potential source of ionizing radiation shall
be so constructed that personal protection against ionizing
radiation is provided under normal operating conditions and under
fault conditions. ..! "INS 1- 7 ~. (...-...J rl~s 814 :)::}) ~x:) ~
. = :: : ,. "~ ,}=0 an OCDU " ~n~61" rz: ~ 'I ~';i' J,f'f 4 . W -
~D I G STE?: lUt l" . ..t TliBE~; R!:. llIlJt) Ir. ~ NS rAPE 'l'l.J
l NC METOHDso. IST~R T-f' 1 NI SH 1,,,,_.. ".~ 1, ,1 lJ L ~1 ::H, I
,L, 11.4iTS~-7 c aSE.' .!. ~ ~. :" ~~r-' I ~ I1"'l~~S1 3:'S'J,
of.:. 2.;, (~, osri ~ I-,!.::, .~.: 91 i:',-'f Mrs....) . .~ .....
:,:, ' . , ~ x ~ _.L t ! t ::.FI _< ..'I 8-12 3:'SJ . t: ...
..:'-, L OSE?fJ .... ~ l'~1 19-11 37S....'1. ::; X ' ,-:,. T2
LKT-115 1. OUTSIDE DIMESlON: (UNlT): mm -= t;n till I iJ a ""'H. ,
07: ? ' ., 5 SO. PI' J C1 T OFf ).' J; l,I,.PI - ,'lIIitl (J- l !'
t.~ . TRF No. IECEN60065G TRF originator: ASTABEAB