08/14/11 1
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
C.N.Tower, Toronto, ON,Craig Media , Canada
Catalin Popescu – 2003
08/14/11 2
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
Project Goals
• 2.5Kw-DIGITAL UHF transmitter – CH66, solid state configuration system using the Digital Mask Filter as a Channel combiner;
• 10Kw-ANALOG UHF transmitter –CH52, combined amplification using the same antenna system as for digital transmitter;
• Line optimized (VSWR better than 1.08), good insulation between the combined paths (more than 60dB). Patching system for the Mask Filter-Channel combiners and the test loads;
• Using a CIBF combining system design, as a Digital Mask Filter and as a Channel combiner.
• System design is up gradable to 2 or 3 more transmitters-limitation only on the antenna system power capability;
• Design the system for installation into a room with ceiling restrictions, existing equipment, air ducting, and new HVAC Units;
08/14/11 3
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
Description
• RF system design according with the customer specifications.
• Issue the specifications of the filtering and combining system;
• Submission and approval of the proposal.• Manufacturing and Installation drawings. • Helping the Test and Service Dept. in the final
commissioning
FOR MORE INFO...
Mr. Catalin Popescu – Application Specialist
Phone: 905 564-9222 Fax: 905 564-9224
08/14/11 4
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
RF system design
• The 2.5KW _UHF –CH66, Solid State air cooled:• Using 1-5/8” line; • Digital Mask Filter as per Canada Industry standard, used as a channel
combiner for the Analog transmitter; • RF design for the UHF band; • 2 digital exciters main-stand-by configuration;
• The 10KW_UHF –CH52, Solid state, Teracom Diplexer, air cooled:
• 1-5/8” for aural and visual before combining;• 3-1/8” for combined (aural +visual on TERACOM Diplexer);• 2 Exciters configuration, with a Traplexer (incl. 3.58 Traps and aural
cavities);
• The key factors for design where: • max line avg. power, • VSWR derating, • max. peak power for the line due to the combination of the 2 and/or
more transmitters into the same transmission line (4-1/16”line flanged), • insertion loss contribution to final power at the gas barrier and space
limitations. • Using the same test load for both channels and ability of patching any
transmitter into the test load or direct to the antenna.
• Power supply electrical designed for both transmitters with reduced power operation on generator;
08/14/11 5
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
RF System design (cont.)RF Flow Diagram-Patching
08/14/11 6
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
RF System design (cont.)AC distribution diagram
08/14/11 7
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
Submission of the proposal for the CH66 and CH52transmitters
• The RF diagram showing the modes of operation of the system;
• The material list count: lines, elbows, couplings, reducers, coaxial switches, probe sections;
• Electrical Diagram design for the 208/120VAC service (breaker size, surge protection, voltage regulation), and reduced power operation on voltage generator;
• Cooling systems design approval with the LARCAN requirements;
• Preliminary installation drawings issued by Application Engineering Dept.
08/14/11 8
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home Filters-Channel
Combiners Data
08/14/11 9
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
Installation Drawings
Overall view-CN Tower
CH 52 AND CH 66
EXISTING 44kw, VHF
Patching and Combining system
08/14/11 10
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
Installation Dwg. Cont.
LARCANLARCAN
Perspective view-CN Tower (future expansion)
Future TX (S)
08/14/11 11
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
Installation Dwg. Cont.
Side view-CN Tower, (details)
08/14/11 12
LARCAN INC.CANADA-2003
Craig Media – CN Tower, ON, CND
RF system Design
Installation drawings
Remote Control
Site Pictures
Description
Home
Installation Dwg. Cont.
Side view and Patching close view