SOLAR POWER CONDITIONING UNIT
& SOLAR CHARGE CONTROLLERS
March 1
2016 A SOLAR PCU IS AN ELECTRONIC UNIT WHICH CONSISTS, SOLAR CHARGER, INVERTER, GRID (MAINS UTILITY) CHARGER, OUTPUT SELECTOR MECHANISM, BATTERY BANK, CONTROL ALGORITHM SOLAR CHARGER. THE SOLAR CHARGER IS THAT PART OF THE PCU WHICH CONVERTS THE SOLAR ENERGY COLLECTED BY THE SOLAR PHOTOVOLTAIC PANEL (SPV) TO CHARGE THE BATTERY
PWM & MPPT
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
ABOUT SOLAR POWER CONDITIONING UNIT
A solar inverter converts the electricity from your solar panels (DC, or direct current) into power that can be used by the plugs in your house for your TV, computer, and other wired products (AC, or alternating current). Panels can’t create AC power by themselves; they need the helping hand of a solar inverter.
Inverters play a crucial role in any solar energy system and are often considered to be the brains of a project, whether it’s a 2-kW residential system or a 5-MW utility power plant. An inverter’s basic function is to “invert” the direct current (DC) output into alternating current (AC). AC is the standard used by all commercial appliances, which is why many view inverters as the “gateway” between the photovoltaic (PV) system and the energy off-taker.
Inverter technologies have advanced significantly, such that in addition to converting DC to AC, they provide a number of other capabilities and services to ensure that the inverter can operate at an optimal performance level, such as data monitoring, advanced utility controls, applications and system design engineering.
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
KEY FEATURE OF SOLAR POWER CONDITIONING UNIT
• DSP BASED TECHNOLOGY • PURE SINE WAVE OUTPUT ON NO LOAD TO FULL LOAD.
• OVER TEMPRATURE PROTECTION WITH COOLING FAN AND SHUTDOWN.
• CONSTANT FREQUENCY OUTPUT.
• TOUCH BUTTONS SELECTION FOR HI-LO BATTERY CHARGING. • NOISE LESS OPEERATION.
• COMPAITABLE WITH GENERATOR.
• INTELLIGENT BATTERY MANAGEMENT SYSTEM. • HIGH CURRENT, REVERSE PHASE, REVERSE BATTERY, OVER LOAD & SHORT CIRCUIT-
PROTECTION. • IDEAL FOR MIXED LOAD APPLICATION.
• TOUCH BUTTON SELECTION FOR CHARGING CURRENT, PROVIDES CLOSED UNIT MANAGEMENT BY TECHNICIAN.
• TOUCH BUTTON SELECTION FOR INVERTER / UPS MODE, PROVIDES QUICK SHIFT FROM INVERTER TO UPS MODE.
• MAINS HI/LOW SELECTABLE FROM NARROW BAND TO WIDE BAND.
• LOW STANDBY CONSUMPTION.
• OPTIONAL USB/SERIAL COMPUTER INTERFACE.
• PROVISION FOR GRID CUM SOLAR SHARED/SELECTIVE CHARGING.
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
PRODUCT RANGE
SOLAR PCU (PWM)
SOLAR PCU (MPPT)
650VA/12V/50A
ON-DEMAND WITH 40A CHARGE CONTROLLER
850VA/12V/50A
ON-DEMAND WITH 40A CHARGE CONTROLLER
1100VA/24V/50A
ON-DEMAND WITH 40A CHARGE CONTROLLER
1400VA/24V/50A
ON-DEMAND WITH 40A CHARGE CONTROLLER
2000VA/24V/50A
2000VA/24V/40A
2500VA/48V/50A
2500VA/48V/40A
3000VA/48V/50A
3000VA/48V/40A
3500VA/48V/50A
3500VA/48V/40A
5000VA/96V/50A
5000VA/96V/40A
7.5KVA/120V/50A
7.5KVA/120V/40A
10KVA/120V/70A
10KVA/120V/40A
10KVA/180V/50A
10KVA/180V/40A
12KVA/192V/70A
12KVA/192V/40A
15KVA/240V/70A
15KVA/240V/40A
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
TECHNICAL SPECIFICATION 650VA/850VA (PWM)
CAPACITY 650VA 850VA
Nominal Input Voltage (DC) 12Volt 12Volt
Input Voltage Range (DC) 10-15 Volt 10-15 Volt
Number of Batteries 1 1
Battery Capacity (Single Battery) 12 V 200 Ah (Max.) 12 V 200 Ah (Max.)
INPUT PARAMETERS
GRID
Grid A.C./ D.G. Recommended Input 220V +/- 5% 220V +/- 5%
Grid A.C./ D.G. Low Cut 120V +/- 5% 120V +/- 5%
Grid A.C./ D.G. Low Cut Recovery 130V +/- 5% 130V +/- 5%
Grid A.C./ D.G. High Cut 270V +/- 5% 270V +/- 5%
Grid A.C./ D.G. High Cut Recovery 260V +/- 5% 260V +/- 5%
Solar
Recommended Panel Wattage UPTO 650W UPTO 850W
Charging Current 50 Amp 50 Amp
Charging Type PWM PWM
OUTPUT PARAMETERS
Mains Output 230V +/- 5% 230V +/- 5%
Frequency Regulation 50Hz +/- 0.05Hz 50Hz +/- 0.05Hz
Efficiency > 90 % > 90 %
Waveform Pure Sinusoidal Pure Sinusoidal
Total Harmonic Distortion < 3% (for linear loads)
< 3% (for linear loads)
Crest Factor > 4:1 > 4:1
Grid Charging Current (can be Changed) 6 Amp – 10 Amp 6 Amp – 10 Amp
Grid Charging Boost Voltage 14.4 V +/- 0.2V Per Battery 14.4 V +/- 0.2V Per Battery
Grid Charging Float Voltage 13.7V +/- 0.2V Per Battery 13.7V +/- 0.2V Per Battery
Low Voltage Shutdown 14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
LED /LCD YES YES
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
TECHNICAL SPECIFICATION 1100VA/1400VA (PWM)
CAPACITY 1100VA 1400VA
Nominal Input Voltage (DC) 24Volt 24Volt
Input Voltage Range (DC) 20-30Volt 20-30Volt
Number of Batteries 2 2
Battery Capacity (Single Battery) 12 V 200 Ah (Max.) 12 V 200 Ah (Max.)
INPUT PARAMETERS
GRID
Grid A.C./ D.G. Recommended Input 220V +/- 5% 220V +/- 5%
Grid A.C./ D.G. Low Cut 120V +/- 5% 120V +/- 5%
Grid A.C./ D.G. Low Cut Recovery 130V +/- 5% 130V +/- 5%
Grid A.C./ D.G. High Cut 270V +/- 5% 270V +/- 5%
Grid A.C./ D.G. High Cut Recovery 260V +/- 5% 260V +/- 5%
Solar
Recommended Panel Wattage UPTO 1100W UPTO 1400W
Charging Current 50 Amp 50 Amp
Charging Type PWM PWM
OUTPUT PARAMETERS
Mains Output 230V +/- 5% 230V +/- 5%
Frequency Regulation 50Hz +/- 0.05Hz 50Hz +/- 0.05Hz
Efficiency > 90 % > 90 %
Waveform Pure Sinusoidal Pure Sinusoidal
Total Harmonic Distortion < 3% (for linear loads) < 3% (for linear loads)
Crest Factor > 4:1 > 4:1
Grid Charging Current (can be Changed) 6 Amp – 10 Amp 6 Amp – 10 Amp
Grid Charging Boost Voltage 14.4 V +/- 0.2V Per Battery 14.4 V +/- 0.2V Per Battery
Grid Charging Float Voltage 13.7V +/- 0.2V Per Battery 13.7V +/- 0.2V Per Battery
Low Voltage Shutdown 14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
LED /LCD YES YES
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
TECHNICAL SPECIFICATION 2000VA/2500VA (PWM)
CAPACITY 2000VA 2500VA
Nominal Input Voltage (DC) 24Volt 48Volt
Input Voltage Range (DC) 20-30 Volt 40-60 Volt
Number of Batteries 2 4
Battery Capacity (Single Battery) 12 V 200 Ah (Max. ) 12 V 200 Ah (Max. )
INPUT PARAMETERS
GRID
Grid A.C./ D.G. Recommended Input 220V +/- 5% 220V +/- 5%
Grid A.C./ D.G. Low Cut 120V +/- 5% 120V +/- 5%
Grid A.C./ D.G. Low Cut Recovery 130V +/- 5% 130V +/- 5%
Grid A.C./ D.G. High Cut 270V +/- 5% 270V +/- 5%
Grid A.C./ D.G. High Cut Recovery 260V +/- 5% 260V +/- 5%
Solar
Recommended Panel Wattage UPTO 2000W UPTO 2500W
Charging Current 50 Amp 50 Amp
Charging Type PWM PWM
OUTPUT PARAMETERS
Mains Output 230V +/- 5% 230V +/- 5%
Frequency Regulation 50Hz +/- 0.05Hz 50Hz +/- 0.05Hz
Efficiency > 90 % > 90 %
Waveform Pure Sinusoidal Pure Sinusoidal
Total Harmonic Distortion < 3% (for linear loads)
< 3% (for linear loads)
Crest Factor > 4:1 > 4:1
Grid Charging Current (can be Changed) 6 Amp – 12 Amp 6 Amp – 15 Amp
Grid Charging Boost Voltage 14.4 V +/- 0.2V Per Battery 14.4 V +/- 0.2V Per Battery
Grid Charging Float Voltage 13.7V +/- 0.2V Per Battery 13.7V +/- 0.2V Per Battery
Low Voltage Shutdown 14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
LED /LCD YES YES
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
TECHNICAL SPECIFICATION 3000VA/3500VA (PWM)
CAPACITY 3000VA 3500VA
Nominal Input Voltage (DC) 48Volt 96Volt
Input Voltage Range (DC) 40-60 Volt 80-120 Volt
Number of Batteries 4 8
Battery Capacity (Single Battery) 12 V 200 Ah (Max. ) 12 V 200 Ah (Max. )
INPUT PARAMETERS
GRID
Grid A.C./ D.G. Recommended Input 220V +/- 5% 220V +/- 5%
Grid A.C./ D.G. Low Cut 120V +/- 5% 120V +/- 5%
Grid A.C./ D.G. Low Cut Recovery 130V +/- 5% 130V +/- 5%
Grid A.C./ D.G. High Cut 270V +/- 5% 270V +/- 5%
Grid A.C./ D.G. High Cut Recovery 260V +/- 5% 260V +/- 5%
Solar
Recommended Panel Wattage UPTO 3000W UPTO 3500W
Charging Current 50 Amp 50 Amp
Charging Type PWM PWM
OUTPUT PARAMETERS
Mains Output 230V +/- 5% 230V +/- 5%
Frequency Regulation 50Hz +/- 0.05Hz 50Hz +/- 0.05Hz
Efficiency > 90 % > 90 %
Waveform Pure Sinusoidal Pure Sinusoidal
Total Harmonic Distortion < 3% (for linear loads) < 3% (for linear loads)
Crest Factor > 4:1 > 4:1
Grid Charging Current (can be Changed) 6 Amp – 20 Amp 6 Amp – 20 Amp
Grid Charging Boost Voltage 14.4 V +/- 0.2V Per Battery 14.4 V +/- 0.2V Per Battery
Grid Charging Float Voltage 13.7V +/- 0.2V Per Battery 13.7V +/- 0.2V Per Battery
Low Voltage Shutdown 14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
LED /LCD YES YES
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
TECHNICAL SPECIFICATION 5KVA/7.5KVA (PWM)
CAPACITY 5KVA 7.5KVA
Nominal Input Voltage (DC) 96Volt 120Volt
Input Voltage Range (DC) 80-120 Volt
100-150 Volt
Number of Batteries 8 10
Battery Capacity (Single Battery) 12 V 200 Ah (Max. ) 12 V 200 Ah (Max. )
INPUT PARAMETERS
GRID
Grid A.C./ D.G. Recommended Input 220V +/- 5% 220V +/- 5%
Grid A.C./ D.G. Low Cut 120V +/- 5% 120V +/- 5%
Grid A.C./ D.G. Low Cut Recovery 130V +/-5% 130V +/- 5%
Grid A.C./ D.G. High Cut 270V +/- 5% 270V +/- 5%
Grid A.C./ D.G. High Cut Recovery 260V +/- 5% 260V +/- 5%
Solar
Recommended Panel Wattage UPTO 5000W UPTO 7500W
Charging Current 50 Amp 50 Amp
Charging Type PWM PWM
OUTPUT PARAMETERS
Mains Output 230V +/- 5% 230V +/- 5%
Frequency Regulation 50Hz +/- 0.05Hz 50Hz +/- 0.05Hz
Efficiency > 90 % > 90 %
Waveform Pure Sinusoidal Pure Sinusoidal
Total Harmonic Distortion < 3% (for linear loads) < 3% (for linear loads)
Crest Factor > 4:1 > 4:1
Grid Charging Current (can be Changed) 6 Amp – 20 Amp 6 Amp – 30 Amp
Grid Charging Boost Voltage 14.4 V +/- 0.2V Per Battery 14.4 V +/- 0.2V Per Battery
Grid Charging Float Voltage 13.7V +/- 0.2V Per Battery 13.7V +/- 0.2V Per Battery
Low Voltage Shutdown 14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
LED /LCD YES YES
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
TECHNICAL SPECIFICATION 10KVA/10KVA (PWM)
CAPACITY 10KVA 10KVA
Nominal Input Voltage (DC) 120Volt 240Volt
Input Voltage Range (DC) 100-150 Volt 200-300 Volt
Number of Batteries 10 20
Battery Capacity (Single Battery) 12 V 200 Ah (Max. ) 12 V 200 Ah (Max. )
INPUT PARAMETERS
GRID
Grid A.C./ D.G. Recommended Input 220V +/- 5% 220V +/- 5%
Grid A.C./ D.G. Low Cut 120V +/- 5% 120V +/- 5%
Grid A.C./ D.G. Low Cut Recovery 130V +/- 5% 130V +/- 5%
Grid A.C./ D.G. High Cut 270V +/- 5% 270V +/- 5%
Grid A.C./ D.G. High Cut Recovery 260V +/- 5% 260V +/- 5%
Solar
Recommended Panel Wattage UPTO 10KW UPTO 10KW
Charging Current 70 Amp 50 Amp
Charging Type PWM PWM
OUTPUT PARAMETERS
Mains Output 230V +/- 5% 230V +/- 5%
Frequency Regulation 50Hz +/- 0.05Hz 50Hz +/- 0.05Hz
Efficiency > 90 % > 90 %
Waveform Pure Sinusoidal Pure Sinusoidal
Total Harmonic Distortion < 3% (for linear loads) < 3% (for linear loads)
Crest Factor > 4:1 > 4:1
Grid Charging Current (can be Changed) 6 Amp – 20 Amp 6 Amp – 30 Amp
Grid Charging Boost Voltage 14.4 V +/- 0.2V Per Battery 14.4 V +/- 0.2V Per Battery
Grid Charging Float Voltage 13.7V +/- 0.2V Per Battery 13.7V +/- 0.2V Per Battery
Low Voltage Shutdown 14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
LED /LCD YES YES
# 178, FUNCTIONAL INDUSTRIAL AREA, PATPARGANJ, DELHI-92
TECHNICAL SPECIFICATION 12KVA/15KVA (PWM)
CAPACITY 12KVA 15KVA
Nominal Input Voltage (DC) 192Volt 240Volt
Input Voltage Range (DC) 160-240 Volt 200-300 Volt
Number of Batteries 16 20
Battery Capacity (Single Battery) 12 V 200 Ah (Max. ) 12 V 200 Ah (Max. )
INPUT PARAMETERS
GRID
Grid A.C./ D.G. Recommended Input 220V +/- 5% 220V +/- 5%
Grid A.C./ D.G. Low Cut 120V +/- 5% 120V +/- 5%
Grid A.C./ D.G. Low Cut Recovery 130V +/- 5% 130V +/- 5%
Grid A.C./ D.G. High Cut 270V +/- 5% 270V +/- 5%
Grid A.C./ D.G. High Cut Recovery 260V +/- 5% 260V +/- 5%
Solar
Recommended Panel Wattage UPTO 12KW UPTO 15KW
Charging Current 70 Amp 70 Amp
Charging Type PWM PWM
OUTPUT PARAMETERS
Mains Output 230V +/- 5% 230V +/- 5%
Frequency Regulation 50Hz +/- 0.05Hz 50Hz +/- 0.05Hz
Efficiency > 90 % > 90 %
Waveform Pure Sinusoidal Pure Sinusoidal
Total Harmonic Distortion < 3% (for linear loads) < 3% (for linear loads)
Crest Factor > 4:1 > 4:1
Grid Charging Current (can be Changed) 6 Amp – 20 Amp 6 Amp – 30 Amp
Grid Charging Boost Voltage 14.4 V +/- 0.2V Per Battery 14.4 V +/- 0.2V Per Battery
Grid Charging Float Voltage 13.7V +/- 0.2V Per Battery 13.7V +/- 0.2V Per Battery
Low Voltage Shutdown 14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
14.4 V +/- 0.2V Per Battery 11.0 V +/- 0.2V Per Battery
LED /LCD YES YES