20
New trends on passive networks installation Standardization Activities in SG15 Edoardo Cottino Rapporteur of Q16/15 FTTH Conference 2011 Workshop on Standardization and Economic Impact Milano, 8 February 2011

FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Embed Size (px)

DESCRIPTION

FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Citation preview

Page 1: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

New trends on passive networksinstallation

Standardization Activities in SG15

Edoardo CottinoRapporteur of Q16/15

FTTH Conference 2011

Workshop on Standardization and Economic Impact

Milano, 8 February 2011

Page 2: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

2

ITU-T SG 15 Standardization activity and FTTH

The standardization of products and installation techniquesrelevant for the deployment of FTTH has been addressed sincemore than ten years by ITU-T under a global umbrella: products,planning, deployment and maintenance

This encompasses the development and updating ofstandards for the construction of the physical layer of theaccess network and the customer premises

The activity related to optical infrastructures and products isunder the leadership of Study Group 15 WP2 “Opticalaccess/transport network technologies and physicalinfrastructures”

Care is taken in the harmonization of standards with differentInstitutions, in particular with IEC TC86 and its WGs

Page 3: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

3

Questions assigned to ITU-T SG15 WP2

Page 4: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Q.16 “Optical physical infrastructure and cables”

In force Recommendations on cable construction

L.10 Optical fibre cables for duct and tunnel application (12/2002)

L.26 Optical fibre cables for aerial application (12/2002)

L.43 Optical fibre cables for buried application (12/2002)

L.58 Optical fibre cables: Special needs for access network (03/2004)

L.59 Optical fibre cables for indoor applications (01/2008)

L.60 Construction of optical/metallic hybrid cables (09/2004)

L.67 Small count optical fibre cables for indoor applications (10/2006)

L.78 Optical fibre cable construction for sewer duct applications (05/2008)

L.79 Optical fibre cable elements for microduct blowing installation (07/2008)

application

This Question includes the study of new cable constructions for different

applications: underground, in ducts, aerial and customer premises.

4

Page 5: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Q.16 “Optical physical infrastructure and cables”

In force Recommendations on installation techniques

L.35 Installation of optical fibre cables in the access network (10/1998)

L.38 Use of trenchless techniques for the construction of underground infrastructures for telecommunication cable installation (09/1999)

L.39 Investigation of the soil before using trenchless techniques (05/2000)

L.48 Mini-trench installation technique (03/2003)

L.49 Micro-trench installation technique (03/2003)

L.57 Air-assisted installation of optical fibre cables (05/2003)

L.61 Optical fibre cable installation by floating technique (09/2004)

L.73 Methods for inspecting and repairing underground plastic ducts (04/2008)

L.77 Installation of cables in sewer ducts (05/2008)

L.82 Optical Cabling shared with multiple operator in buildings (07/2010)

L.83 Low impact trenching technique for FTTx networks (07/2010)

L.84 Fast Mapping of Underground Network (07/2010)

This Question address the investigation of new cost effective solution for

the construction of the infrastructures and for cable laying.

5

Page 6: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

6

Outside Plant infrastructures challenges

It represents the prevalent cost in the customer connection. Withtraditional techniques is in the range between 60% (in urban areas) and90% (in rural areas) of the total plant cost.

The trend of miniaturization of the optical cable structures as well as theavailability of low bend fibres allows the reduction of the ducts dimensionsand, consequently, of the dimensions of the road cutting

To pave the way to FTTH, Telcos are looking for technologies allowing:

To re-use as far as possible the existing infrastructures (evenif partially occupied by other cables)

To minimize the environmental impact by means of reduceddimension diggig techniques (or no dig at all!)

To reduce the skill of manpower

ITU-T SG15 is working on the standardization of all the availabletechnologies to enable FTTH development

Page 7: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

7

Optical cables miniaturization trend

96 o.f.

Diameter 15 mm

Weight 200 Kg/Km

Bending Radius 210 mm

Winch installatiion

Up to 120 (144) o.f.

Diameter 8 mm

Weight 50 Kg/Km

Bending Radius 160 mm

Air blowing installation

Traditional cable Mini cable

The reduction of diameter and weight of the mini cables allowthe installation in very small ducts with innovative techniques asair blowing.

The same products can be installed in overhead plants or on building facades.

Page 8: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

8

Infrastructure miniaturization trend

In the same way also the dimensions of ducts can be reduced.

In this new scenario large dimension road cuttings areunnecessary, as sections of several cm or some tens cm aresufficient.

Outer Diameter 40

or 50 mm

Diameter 10/14 mm

(inner/outer)

TRADITIONAL MINIATURIZED

Page 9: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Low impact trenching techniques

Installation of mini ducts structures inside a small dimension trench:width less than 5 cm and depth in the range 20-30 cm

Use of low environmental impact trenching machines

Use of new material to empty the dig to avoid road restoration

Reduction of “environmental costs” and “social costs”

All the activities permit to open and close the working site in thesame day

Trench saw combined with suction machine

Innovative material before and after hardening completed

9

Page 10: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Examples of work site in urban area

10

Page 11: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

11

”Light” No-Dig

It is a guided drilling technique with small machines (also for use in manholes) for the laying of a 40 mm single duct, equipped with 4 miniducts and with anti rodent protection

It represents an evolution of the technique described in L.38

Advantages Drawbacks

Ease to obtain permissions Need of a georadar survey

Zero impact on environment and traffic Dependance on the soil type

No need of expensive road restoration

Page 12: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Installation of ducts and cables in existing infrastructures

Outfitting of existing ducts (telcos, street lighting, power..) with 10/12 mm mini ducts and use of completely dielectric minicables

Separation of the telecommunication access points with the use of reduced dimensions manholes

12

Page 13: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

13

Installation of ducts and cables in existing infrastructures

Advantages Drawbacks

Cost effectiveness Coexistence with other services

Immediate availability ofInfrastructure

Reduced protection of the plant (it needs a protection system)

No need of expensive road restoration

Definition of the “rules” with the infrastructureowner

Low impact on environment and traffic

Definition of safety procedure for the O&Mactivities

Page 14: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Fast solution for mapping underground networks

It should detect univocally underground services and display in real time the 3D results about buried utilities

It should be user friendly, with a man-machine interface that helps also not skilled people to understand the results

It should geo-reference traces and they should be imported in a GIS system or in a CAD file

14

Page 15: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Example of georeferenced resultimported in GIS system …

Distance

of buried

utility

from

Start

Point

Deep of

buried

utility

1515

Page 16: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

16

Existing building infrastructures challenges

The most critical issues of the FTTH deployment are related tothe cabling of existing buildings, especially in metropolitanareas, due to:

• Limited availability of TLC infrastructures

• Trouble in obtaining permissions for installing “at sight”solutions

• Old rules related to copper that do not allow to exploitthe dielectric characteristics of optical fibres to make itsinstallation more flexible

ITU-T SG15 is working on the standardization of all the new products

accessories

test methods

and installation techniques

optimized for the “existing buildings scenario”

Page 17: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

17

About installation in buildings….

Page 18: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Q.16 Work in Progress

Cable construction area

L.caind Optical fibre cable functions for premises indoor application

L.cda Optical fibre cable constructions for drop application

L.cna Optical fibre cable constructions for new application

Installation techniques area

L.cigd Installation of cables in gas ducts

L.ciwd Installation of cables in water ducts

L.coi Solutions for installation of ducts and cables in an occupied infrastructure

L.fubt Installation of optical fibre units or mini-cables by blowing technique

L.recc Installation of optical fibre cable by replacement of existingcopper cables

18

Page 19: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

19

Conclusions

The success of the FTTH challenge relies on the possibility for all the Players to build up an infrastructure with the state of the art, most reliable, cost effective and homogeneous technologies. For this purpose STANDARDS are needed.

In the last ten years of activity, ITU-T (SG15 WP2 and SG6) produced about 40 Recommendations related to FTTH physical layer; about 20 Recommendations in preparation in this study period (2009 – 2012) address fibers reliability items, cost effective installation techniques, cables and materials.

Relationships have been built with other Standardization Bodies (such as IEC, FTTH Council, JTC1/SC25,-..) in order harmonize standards and avoid duplication of efforts.

The set of Recommendations, Handbooks, Technical Reports produced, will speed up the FTTH deployment, as they give positive answers to the most topical issues and allow the FTTH Players (Operators, Investors…) to make the correct choices for the implementation of a future-proof optical fibre access network.

Page 20: FTTH Conference 2011 Workshop New Trends on Passive Networks Installation Eduardo Cottino ITU

Thank you!

[email protected]