Compact and low-costmonitoring of
conductive liquids.Magnetic-inductive
flow meteringfrom ifm.
Volumetric flow sensor efector mid. High-precisionmeasurement, display and signalling of liquid media.
For industrialapplications
Coolant monitoring Cooling water monitoring
Ideal in widelybranched coolingsystems, e.g. weld -ing lines. Thevolumetric flowsensor efector middetects very smalldeviations fromthe specified volu-metric flow quan-tity, for examplefor leaks, andmonitors at thesame time thetemperature ofthe cooling water.This guaranteesprocess safety andquality.
Decentraliseddetection andmonitoring ofliquid media.
The diagnosticfunctionality ofefector mid, e.g.analogue outputs,binary limit values,consumed quanti-ties during thespecified period ortemperature mo n -itoring in themedium, enablesthe reliable opera-tion of cooling cir -cuits and systems.Due to the contin -uous monitoringthe sensor can beperfectly integrat -ed into the condi-
Condition-basedmaintenance.
Monitoring ofconductive liquids.
tion-based main-tenance concepts.This enhances thereliability of theplant; uptime isincreased. Expen -sive consequentialdamage resultingfrom lack of cool -ant is prevented.By integration intoa real-time-main-tenance conceptmaintenance canbe implementedat the right time,in the right place,using the rightmaterial and oper -ators.
The magnetic-inductive volumet -ric flow sensor issuitable for moni-toring conductivemedia. The mediahave a differentelectrical conduc -tivity. efector midmeasures liquidmedia from aconductivity of> 20 μS/cm.
electrical conductivity
sea water (salt)
water glycol mixtures
water-based coolants
drinking water
industrial water
Measuring lengthand electronics areintegrated into arobust and com-pact housing. Sootherwise usualinlet and outletpipe lengths canbe reduced to aminimum. Pressureloss is negligible.
Compact, informativeand easy to install.
Four-digit alpha-numeric displayfor information onsite: current volu-metric flow, accu-mulated totalquantity andmedium tempera-ture. l/min or m3/hcan be selected asthe unit of mea -surement. TwoLEDs indicate theswitch points.Mounting viaR 1/2 or R 3/4adapter ensureseasy installation inthe pipe.
Cooling process optimisation Water supply documentation
efector mid – thereliable and low-cost solution formonitoring theexact supply andconsumption ofliquids in industri-al processes. Dueto the measuringrange of 0 to25 l/min and anaccuracy of ± 2 %of the measuredvalue the unit canbe used in a widerange of applica-tions. Volumetricflow in the oppo -site direction isalso indicated.
alphanumericdisplay
switch point indication
programmingbuttons
Phot
o re
fere
nce
Indu
ctio
n ha
rden
ing:
R. R
ieke
r G
mbH
, Lei
ngar
ten
Waf
er p
rodu
ctio
n: c
entr
othe
rm t
herm
al s
olut
ions
Gm
bH+
Co
KG
, Bla
ubeu
ren
Operating voltage [V] 19...30 DC*
Current rating [mA] 2 x 200 –
Short-circuit protection, pulsed 2 x 200
Analogue output 4...20 mA / 0...10 V (4...20 mA: max: 500 / 0...10 V: min. 2000 Ω)
Flow monitoringMeasuring range [l/min / m3/h] 0...25 / 0...1.5
Measurement error [%]
Setting range [l/min / m3/h]Set point, SPAnalogue start point, ASPAnalogue end point, AEP
Start-up delay [s]
± (2 % measured value + 0.5 % VMR)
0.25...25 / 0.015...1.50...20 / 0...1.2
5...25 / 0.3...1.5
0...50
Temperature monitoringMeasuring range [°C] -20...80
Measurement error [°C] ± 2.5 (Q > 1 l/min)
Pressure resistance [bar] 16
Medium temperature [°C] -10...70
Reverse polarity, overload prot. 2 x 200
Technical data volumetric flow sensor efector mid
Application area conductive liquids(conductivity: ≥ 20 μS/cm / viscosity: < 70 mm2/s at 40 °C)
Electrical design
Connection
DC PNP/NPN
4-wire
DC PNP
4-wire
Output 1
Output 2
normally open / normally closed programmableor pulse
normally open / normally closed programmableor analogue (4...20 mA / 0...10 V, scalable)
analogue(4...20 mA)
–
Process connection G 1/2 male thread
Order no. SM6000 SM6050
Sockets
Description Order no.
2 m PUR, M12 angled, without LED EVC004
5 m PUR, M12 angled, without LED EVC005
Accessories (selection)
Description Order no.
Adapter G 1/2 - R 3/4Process connection G 3/4 flat seal
Adapter G 1/2 - R 1/2
110
73
M12x1
16
G G2
1
21
M12x1
54
*to EN50178, SELV, PELV
Setting range [°C]Set point, SPAnalogue start point, ASPAnalogue end point, AEP
-19.8...80.0-20...600...80
Display unitOutput statusMeasured valuesProgramming
6 LEDs green (l/min, m3/h, m3, 103, °C)2 LEDs yellow
4-digit alphanumeric display4-digit alphanumeric display
––––
Protection IP 67, III
Housing materials stainless steel (316S12); stainless steel (316S16); PBT-GF 20; EPDM/X (Santoprene)
Sensor materials stainless steel (316S12); PEEK (polyetheretherketone); FKM
Connection M12 connector; gold-plated contacts
E40189
E40199
Grounding clamp E40196
SM6000
Ensuring product qualityand plant up-time.
Volumetric flow sensorefector mid:
Simultaneous monitoringof volumetric flow quantityand temperature of con-ductive liquids.
Functionality and precisionat the right price.
Local indication of thecurrent volumetric flowquantity, total quantity andtemperature.
For external evaluation:Switching, pulse and ana -logue outputs for signaland control tasks.
Less cost:Setting and monitoring ofcooling circuits for optimumperformance.
More safety:Immediate detection ofeven very small leaks.
High transparency:Counting and allocation ofconsumed quantities.
Exactly right:Exact determination ofliquid quantities.
Magnetic-inductiveflow metering.
converted in theevaluation electro-nics. As the pipecross-section isdefined, thevolu met ric flowquantity can bedeterminedexactly.
No moving com-ponents are used,therefore thesystem works relia-bly, wear andmaintenance free.
The volumetricflow sensor isbased on Faraday’sprinciple of induc-tion. The conduc-tive mediumflowing through apipe in a magneticfield generates avoltage which isproportional tothe flow velocityor volumetric flowquantity. This vol-tage is tapped viaelectrodes and
M = magnetE = electrodesV = flow velocity
V
M
M
E
ifm a
rtic
le n
o. 7
5112
74 ·
We
rese
rve
the
right
to
mak
e te
chni
cal a
ltera
tions
with
out
prio
r no
tice.
· Pr
inte
d in
Ger
man
y on
non
-chl
orin
e bl
each
ed p
aper
. 02
/08
Over 70 locations worldwide – at a glance atwww.ifm.com
visit our website:
www.ifm.com
Position sensorsand object recognitionInductive sensorsCapacitive sensorsMagnetic sensors,cylinder sensorsSafety technologyValve sensorsPhotoelectric sensorsObject recognitionEncodersEvaluation systems,power suppliesConnection technology
Fluid sensorsand diagnostic systemsLevel sensorsFlow sensorsPressure sensorsTemperature sensorsDiagnostic systemsEvaluation systems,power suppliesConnection technology
Bus systemsBus system AS-InterfacePower suppliesConnection technology
Identification systemsDataMatrix code-readingsystemsRF-identification systemsPower suppliesConnection technology
Control systemsControl systemsfor mobile vehiclesConnection technology
Overview ifm main catalogues:
ifm electronic gmbhTeichstraße 445127 EssenTel. +49 / 0201 / 2 42 20Fax +49 / 0201 / 2 42 22 00E-Mail: [email protected]