Upload
sherly-saerang
View
89
Download
2
Tags:
Embed Size (px)
Citation preview
ANALIZER MEASUREMENT : ENERGY ANALYZER CIRCUTOR AR5-L - CURRENT [ AMPERE ]WITHOUT SOMAR INTEGRA / POWERBOSS 1.927 AWITH SOMAR INTEGRA / POWERBOSS 1.293 A
% SAVING 32.90 %
CURRENT [ AMPERE ] RUNNING MEASUREMENT
GRAPHIC WITHOUT SOMAR INTEGRA / POWERBOSS AND WITH SOMAR INTEGRA/POWERBOSS
ENERGY SAVING REPORTTYPE OF SI / PBI : PBI 7.5/V220-480 SCHEMATIC CONNECTION : DIRECT ON LINE CONNECTIONEQUIPMENT / MACHINE : CONVEYOR 7,5KW CUSTOMER : ANTAM POMALATESTING INSTRUMENT : CIRCUTOR AR5-L ENERGY ANALYZER
AMPERE SAVING
32.90%
pg. 1
SOMAR INTEGRA [ POWERBOSS ] INSTALLED AT CONVEYER 7,5KW
ENERGY TEST - AMPERE RUNNING
PT ENERCON EQUIPMENT COMPANYGedung Aldevco II - 4th Floor
Jl. Warung Jati Barat Raya No. 75 Jakarta, IndonesiaT: 62 21 7941182 F: 62 21 7941184 W: www.enercon.co.id E: [email protected]
GRAPHIC WITHOUT SOMAR INTEGRA/POWERBOSS AND WITH SOMAR INTEGRA/POWERBOSS
ANALIZER MEASUREMENT : ENERGY ANALYZER CIRCUTOR AR5-L - CURRENT [ AMPERE]WITHOUT SOMAR INTEGRA / POWERBOSS 21.136 A
WITH SOMAR INTEGRA / POWERBOSS 5.639 A
% SAVING 73.32%
CURRENT [ AMPERE ] STARTING MEASUREMENT
2
ENERGY SAVING REPORTSOMAR INTEGRA [ POWERBOSS ] INSTALLED AT CONVEYER 7,5KW TYPE OF SI / PBI : PBI 7.5/V220-480 SCHEMATIC CONNECTION : DIRECT ON LINE CONNECTIONEQUIPMENT / MACHINE : CONVEYOR 7,5KW CUSTOMER : ANTAM POMALATESTING INSTRUMENT : CIRCUTOR AR5-L ENERGY ANALYZER
PT ENERCON EQUIPMENT COMPANYGedung Aldevco II - 4th Floor
Jl. Warung Jati Barat Raya No. 75 Jakarta, IndonesiaT: 62 21 7941182 F: 62 21 7941184 W: www.enercon.co.id E: [email protected]
AMPERE SAVING
73.32%
ENERGY TEST - AMPERE STARTING
ANALIZER MEASUREMENT : ENERGY ANALYZER CIRCUTOR AR5-L - KWWITHOUT SOMAR INTEGRA / POWERBOSS 0.422 KW
WITH SOMAR INTEGRA / POWERBOSS 0.330 KW
% SAVING 21.80%
GRAPHIC WITHOUT SOMAR INTEGRA/POWERBOSS AND WITH SOMAR INTEGRA/POWERBOSS
3
ENERGY SAVING REPORTSOMAR INTEGRA [ POWERBOSS ] INSTALLED AT CONVEYER 7,5KW TYPE OF SI / PBI : PBI 7.5/V220-480 SCHEMATIC CONNECTION : DIRECT ON LINE CONNECTIONEQUIPMENT / MACHINE : CONVEYOR 7,5KW CUSTOMER : ANTAM POMALATESTING INSTRUMENT : CIRCUTOR AR5-L ENERGY ANALYZER
PT ENERCON EQUIPMENT COMPANYGedung Aldevco II - 4th Floor
Jl. Warung Jati Barat Raya No. 75 Jakarta, IndonesiaT: 62 21 7941182 F: 62 21 7941184 W: www.enercon.co.id E: [email protected]
POWER [ KW] RUNNING MEASUREMENT
ENERGY TEST - KW RUNNING
KW SAVING
21.80%
ANALIZER MEASUREMENT : ENERGY ANALYZER CIRCUTOR AR5-L - KWWITHOUT SOMAR INTEGRA / POWERBOSS 6.390 KW
WITH SOMAR INTEGRA / POWERBOSS 1.371 KW
% SAVING 78.54%
GRAPHIC WITHOUT SOMAR INTEGRA/POWERBOSS AND WITH SOMAR INTEGRA/POWERBOSS
4
ENERGY SAVING REPORTSOMAR INTEGRA [ POWERBOSS ] INSTALLED AT CONVEYER 7,5KW TYPE OF SI / PBI : PBI 7.5/V220-480 SCHEMATIC CONNECTION : DIRECT ON LINE CONNECTIONEQUIPMENT / MACHINE : CONVEYOR 7,5KW CUSTOMER : ANTAM POMALATESTING INSTRUMENT : CIRCUTOR AR5-L ENERGY ANALYZER
PT ENERCON EQUIPMENT COMPANYGedung Aldevco II - 4th Floor
Jl. Warung Jati Barat Raya No. 75 Jakarta, IndonesiaT: 62 21 7941182 F: 62 21 7941184 W: www.enercon.co.id E: [email protected]
POWER [ KW ] STARTING MEASUREMENTKW SAVING
78.54%
ENERGY TEST - KW STARTING
GRAPHIC WITHOUT SOMAR INTEGRA/POWERBOSS AND WITH SOMAR INTEGRA/POWERBOSS
5
ENERGY SAVING REPORTSOMAR INTEGRA [ POWERBOSS ] INSTALLED AT CONVEYER 7,5KW TYPE OF SI / PBI : PBI 7.5/V220-480 SCHEMATIC CONNECTION : DIRECT ON LINE CONNECTIONEQUIPMENT / MACHINE : CONVEYOR 7,5KW CUSTOMER : ANTAM POMALATESTING INSTRUMENT : CIRCUTOR AR5-L ENERGY ANALYZER
PT ENERCON EQUIPMENT COMPANYGedung Aldevco II - 4th Floor
Jl. Warung Jati Barat Raya No. 75 Jakarta, IndonesiaT: 62 21 7941182 F: 62 21 7941184 W: www.enercon.co.id E: [email protected]
POWER FACTOR [ PF ] RUNNING MEASUREMENT ENERGY TEST - PF RUNNING
6
ENERGY SAVING REPORTSOMAR INTEGRA [ POWERBOSS ] INSTALLED AT CONVEYER 7,5KW TYPE OF SI / PBI : PBI 7.5/V220-480 SCHEMATIC CONNECTION : DIRECT ON LINE CONNECTIONEQUIPMENT / MACHINE : CONVEYOR 7,5KW CUSTOMER : ANTAM POMALATESTING INSTRUMENT : CIRCUTOR AR5-L ENERGY ANALYZER
PT ENERCON EQUIPMENT COMPANYGedung Aldevco II - 4th Floor
Jl. Warung Jati Barat Raya No. 75 Jakarta, IndonesiaT: 62 21 7941182 F: 62 21 7941184 W: www.enercon.co.id E: [email protected]
K E S I M P U L A N
•KW SAVING Efisiensi KW akan mengurangi nilai pemakaian KWH (energy listrik) oleh motor utama, sehingga mengurangi biaya pengeluaran tagihan listrik untuk motor tersebut.
•KVAR SAVINGEfisiensi KVAR akan mengurangi panas yang timbul akibat adanya losses/kehilangan daya motor, sehingga dengan berkurangnya KVAR akan memperpanjang faktor lifetime dari motor dan perbaikan Power factor.
•KVA SAVINGMotor & Peralatan lainnya yang berhubungan (cables, fuses, contactors dan overloads) akan dialiri oleh arus current yang lebih kecil sehingga tidak akan mudah rusak dan akan mengurangi biaya maintenance serta mengurangi biaya beban pinalti KVA (KVA Dis-insentif). Bagi konsumen yang menggunakan sumber listrik (Power Plant) sendiri atau generator dengan bahan bakar solar, maka KVA saving ini akan mengurangi konsumsi pemakaian solar pada saat offload dan meningkatkan kemampuan generator tersebut untuk beroperasi.
Keuntungan lain yang didapatkan dengan dipasangnya sSOMAR INTEGRA / POWERBOSS, antara lain:
•Soft Start & Soft StopProses Start & Stop motor akan lebih halus bila dibandingkan dengan instalasi motor yang hanya menggunakan Direct on line dan star-delta. Efeknya adalah tiadanya hentakan saat starting dan proses stop yang tiba-tiba sehingga komponen mekanikal motor akan lebih tahan lama.
•3 Phase ProtectorBila terjadi hilangnya salah satu phase power listrik, maka Powerboss akan bekerja secara otomatis untuk memutuskan aliran listrik ke motor agar motor tidak terbakar akibat overload/over