BUILDING
SERVICES
LTD.
Differentiation
We deliver XTRA value
in the Quality Products
& Building Serviceswe provide
BUILDING
SERVICES
LTD.
Services
On-site field inspection & preventative maintenance
reports:
Included in our inspection report: Image journal of job site condition Detail description of each image Analysis & summary report Proposed repairs Suggested future maintenance
BUILDING
SERVICES
LTD.
Sample Inspection Report
*Excerpt from 3551 Kingsway report: Elevation photo with areas of concern
annotated Description of problem area with thumbnail
reference photo Close up photo details Summary list of proposed repairs Recommendation & Warranty
*This sample overview consists of 17 of 225 slides included in the original preventative maintenance report done for 3551 Kingsway.
Photo 1
2
1
3
4
North West Elevation: Photo 1
1. Balcony leaking at soffit,mildew stains on stucco
2. Cracks at lower corner of windows 3. Efflorescence (white powdery
staining)4. Membrane failure at exposed
concrete slab
NOTATION: small joint sealant at window mitres common throughout the building
Photo 2
1
23
NW, Centre Elevation: Photo 2
1. Broken vent cover; head sill flashing at windows allows water ingress
2. Staining on wall from weep holes at base of windows (indicates condensation within the units is a problem)
3. Hair line cracks at control joint transitions.
NOTATION: Install small joint sealant at interior window mitres to prevent moisture within the walls.
Photo 3
32
1
NW,Centre-Left Elevation: Photo 3
1. Balcony leaking at two locations at soffit due to membrane failure on balcony surface. (See photo 4 & 5 close-up images)
2. Typical condition of vent covers; broken & rusted (See photo 4 & 5 close-up images)
3. Typical staining at base of window weep holes; accompanied by cracks at stucco joints
Photo 4
Photo 5
BUILDING
SERVICES
LTD.
Elements of Concern
GENERAL: Flashing has been penetrated with
nails & compromised Sealant missing at flashing transitions
to columns Sealant missing at stucco to column
transitions Voids in concrete walls Cracks at wall and sealant missing at
other flashing transitions.
Adverse conditions
Debris left on decks
Heat Damage to Membrane
Fire Hazards
Improper sloping and
water ponding
Poor maintenance
Penetrations through deck membrane
BUILDING
SERVICES
LTD.
Elements of Concern
SPECIFIC: UNIT #8 Damage to window sill caused by
condensation in upper & lower bedrooms
Sliding door frame to south deck shows extensive mold infiltration
Water is ponding directly in front of sliding door due to improper sloping of deck
Deck membrane damaged and wood decking below is exposed & compromised
BUILDING
SERVICES
LTD.
Elements of Concern
SPECIFIC: UNIT #8 (continued) Rain gutter is broken at wall transition Sealant at fire wall to metal transition
has failed Wall at inside corner is cracked &
damaged Exposed fasteners penetrating flashing Membrane surface is pitted and has
failed Flashing at door sill is detached and
failing
BUILDING
SERVICES
LTD.
Recommendations
Bathroom fans should be checked for speed, dust & volume.
Install fans to go on automatically with bathroom lights
Consider higher CFP volume fans
BUILDING
SERVICES
LTD.
Recommendations
Install DOW 123 System; this requires replacing all sealants at window perimeters & flashing transitions with DOW 790-795 sealant (20yr warranty)
Install DOW 123 tape at vertical & horizontal stucco expansion joints
Re-paint all stucco walls with Dow Corning Allguard Coating after facades have been cleaned
All concrete coated with high quality exterior acrylic latex
Balcony waterproofing is to be renewed using Vulkem 350/351 products according to the manufacturers specifications
Installation of traffic coating with new cover flashing where required
BUILDING
SERVICES
LTD.
Warranty
XTR Building Services ten (10) year warranty on all coating systems
Dow Corning ten (10) year warranty on all coating material
XTR Building Services ten (10) year warranty on all applied sealants
XTR Building Services five (5) year workmanship warranty on all balcony waterproofing including labor and materials This is a new warranty benchmark which exceeds current Industry Standards and is offered exclusively by XTR Building Services
XTR has over 20 years experience in the Preventative Maintenance Industry