61
ANALYSIS OF NITR CAMPUS NAME- DEBANJALI SAHA ROLL- 113AR0014

campus analysis

Embed Size (px)

Citation preview

Page 1: campus analysis

A N A L Y S I S O F N I T R C A M P U S

NAME - D E B A N J A L I S A H A

RO L L - 1 1 3 A R 0 0 1 4

Page 2: campus analysis

ANALYSIS IN MACRO LEVEL

Page 3: campus analysis
Page 4: campus analysis

1

2

3

4

5

67

8

12

1413

10 11

9

1.EC-EI2.GOLDEN JUBILY3.LA14.LA115.BMBT6.CHEMICAL7.WORKSHOP8.MECHANICAL9.CS10.MAIN BUILDING11.LIBRARY12.ARCHITECTURE13.MINING14.CERAMIC

Page 5: campus analysis

MAIN GATE

MANGLA MANDIR

EC-EI GATE

LA 2 GATE

LA 1 GATE

CERAMIC GATE

TIIR GATE

ACCESS ROADS TO THE MAIN CAMPUS

Page 6: campus analysis

EXISTING ROAD NETWORKVEHICULAR ROAD

PEDESTRAIN ROAD

Page 7: campus analysis

EXISTING AMINITIES

CANTEENS AND TEASTALLS

PARKING SPACES

FIELD

Page 8: campus analysis

EXISTING BUILT UP PLACES

BUILT FORMS

Page 9: campus analysis

BIO-CLIMATIC CHART FOR RANCHI

JAN MONTH

MAY MONTH

Page 10: campus analysis
Page 11: campus analysis

PSYCHROMETRIC CHART FOR TEMPERATURE

Page 12: campus analysis

PSYCHROMETRIC CHART FOR WIND SPEED

Page 13: campus analysis

PSYCHROMETRIC CHART FOR COMFORT(OCT-MAR)

Page 14: campus analysis

PSYCHROMETRIC CHART FOR COMFORT(APR-SEPT)

Page 15: campus analysis

Jan MORNING

Jan EVENING

Jan AFTERNOON

Page 16: campus analysis

May MORNING

May EVENING

May AFTERNOON

Page 17: campus analysis

FLORA AND FAUNA

SAL(shorea robusta)

Sahaj(Terminalia tomantosa):Bija or Piasal (Pterocarpus marsupium):

Kurum (Hadina Cordifolia)

Page 18: campus analysis

Gambhari(Gmelina arborea)

Kusum(Scheleichera trijuga)

Aonla(Phyllonthus emblica):

Mahua (Bassia latifolia):

FLORA AND FAUNA

Page 19: campus analysis

The common lawn shared by La and BM_BT dept is a good interactive space and the trees and

landscaping provides good microclimate for both the building. But during high peak of the day its not

been used, so proper landscaping with shades can be provided over there.

The lawn in front of library with the tea stall(very good interactive space) , it even has rose garden and

some deciduous trees.

The gardens between main building and the mechanical department creates a buffer between both the

blocks yet it keeps a visual connectivity.

The trees around NCC ground provides aesthetics and shade to the main building but not for reducing

noise and smoke.

The green spaces helps to decrease the surrounding temperature.

The courtyard in all the dept can be properly maintained and landscaped to make it much more

interactive

Seating can be placed in the common spaces

Rows of trees can be there at the side of the road to provide shade and also a linear vista

INFERENCE

Page 20: campus analysis

ANALYSIS IN MICRO LEVEL

Page 21: campus analysis

COMPUTER SCIENCE DEPARTMENT

FIRST FLOOR PLAN

Page 22: campus analysis

COMPUTER SCIENCE DEPARTMENT

SECOND FLOOR PLAN THIRD FLOOR PLAN

Page 23: campus analysis

INFERENCE (CS DEPT) CLIMATE: day light blocked by trees

CLIMATE: double facade is present

CLIMATE: no trees on south side

BYELAWS: ramp is there on the east side for differently able people

BYELAWS: fire safety plan required

AREA: area for individual room is of standard

FUNCTION: The distance between the two staircase is more than 40mts

FUNCTION: the space behind the new lab is of no use

FUNCTION :Courtyard not properly in use

FUNCTION: toilet on SW acts as a buffer zone

FUNCTION: we can have basement for earth bumping

FUNCTION: can have a coffee shop behind the window for more interaction

FUNCTION: courtyard need to be made much more interactive

PROXIMITY: this dept is in proximity with EC-EI dept.

POXIMITY: canteen, stationary shop and SAC is in proximity

ECOLOGY: trees are there in north side and in front it is been landscaped a bit

Page 24: campus analysis

MINING DEPARTMENT

GROUND FLOOR PLAN

Page 25: campus analysis

MINING DEPARTMENT

FIRST FLOOR PLAN SECOND FLOOR PLAN

Page 26: campus analysis

INFERENCE (MN DEPT)• CLIMATE: Trees on the side provides cool micro climate inside

• BYE-LAWS: No fire escape staircase and not designed for differently able person

• BYELAWS: Circulation space=35%, but must be 30%

• AREA: 375 students and 4 classroom for that not sufficient

• AREA: Wide corridor of 3.6mts

• AREA: staircase with no external wall

• AREA: Research lab more spaces (good) but labs where chemicals are used or computer lab are having less space

• FUNCTION:Parking share by ceramic department

• FUNCTION: Faculty room in front has no proper ventilation.

• FUNCTION : Columns are place badly, so they can be sifted for utilization of spaces

• FUNCTION: No plinth in front, reptiles can enter

• FUNCTION: Courtyard not properly utilized, mainly used for drainage purpose and for sampling lab

• FUNCTION:Total 3 entrances, 2 on the side are not utilized and remain close

• FUNCTION:Courtyard accessed from only one path

• FUNCTION:Double loaded corridor with no proper ventilation

• PROXIMITY: with architecture and ceramic department

• ECOLOGY: trees- sal, ashoka

Page 27: campus analysis

MAIN BUILDING

GROUND FLOOR PLAN

Page 28: campus analysis

MAIN BUILDING

FIRST FLOOR PLAN

Page 29: campus analysis

MAIN BUILDING

SECOND FLOOR PLAN

Page 30: campus analysis

MAIN BUILDING

THIRD FLOOR PLAN

Page 31: campus analysis

INFERENCE (MAIN BUILDING)• CLIMATE:Trees in front of the main building is just for aesthetics and not for controlling the wind and smoke

• CLIMATE:The fins in the window are not enough to protect the rooms from sunlight

• BYELAWS:The staircase can act as a fire shaft

• BYE-LAWS: no fire safety escape

• BYELAWS: not for differntky able people

• AREA:Open spaces=40% and circulation= 30%

• AREA:Width of corridor not constant in all the places

• AREA: Huge classroom broken down to create partition

• AREA:It has metallurgy, civil, physics, chemistry, mathematics and life science department

• AREA: the room and labs are following the standard, but the civil labs are too much congested

• FUNCTION:Stage is there in front of the courtyard

• FUNCTION: Linear vista through the main gate

• FUNCTION:4 access way- main gate, mangla mandir, CR dept and EC dept

• FUNCTION: Double loaded corridor thus no proper light and ventilation

• FUNCTION:AC vents run all through the corridor

• FUNCTION:Courtyard not used for interactive space

• FUNCTION:The newly constructed courtyard used by the professor as the smoking zone

• FUNCTION:All the corridor is facing inside, good design from wind point of view

• PROXIMITY: The individual labs and there classroom are not in proximity with each other

• ECOLOGY:Right side of main building have tress mainly- ashoka, neem tree

• ECOLOGY:Banayan tress at the side a great interactive space

Page 32: campus analysis

LIBRARY

GROUND FLOOR PLAN

Page 33: campus analysis

LIBRARY

FIRST FLOOR PLAN

Page 34: campus analysis

LIBRARY

SECOND FLOOR PLAN

Page 35: campus analysis

INFERENCE (LIBRARY)• CLIMATE: should have proper lighting in the interior

• CLIMATE: Humidity needs to be controlled as there is book stalking- Double Humidifiers

• BYELAWS: No fire escape staircase is there

• BYELAWS: not for differently able people, but lift is there

• AREA: no sufficient num of toilets. Toilet for females only in ground floor.

• AREA: the area is sufficiently but need proper arrangement

• AREA: entrance and baggage counter, reception, book issue counter need more space

• FUNCTION: Control rooms in all the floor.

• FUNCTION: AC control room till G+1.

• FUNCTION: G+1 acts as a behaviour room and students are restricted.

• FUNCTION: We need an interactive entrance, much informal one

• FUNCTION: We can have a museum with it, we can display over there about the things made in the college campus like Digital display & Art room.

• FUNCTION: Spaces which doesn’t require a control environment can be the clock room.

• FUNCTION: Stacking and reading space needs AC

• PROXIMITY: with architecture and main building

• ECOLOGY: green lawn present in front which is a good interactive space

Page 36: campus analysis

BM-BT DEPARTMENTGROUND FLOOR PLAN FIRST FLOOR PLAN

Page 37: campus analysis

BM-BT DEPARTMENTSECOND FLOOR PLAN THIRD FLOOR PLAN

Page 38: campus analysis

INFERENCE (BM-BT DEPARTMENT)• 2 entrances

• No fire exit.

• Travel distance is more than 40mts metres between 2 staircase.

• 540 is the present students capacity. It can accommodate more people around 900 students. So used for extension of building.

• Ramp 1:10 ratio, thus it couldn’t be used by wheel chairs.

• Courtyard not properly utilized. It doesn’t properly gives ventilation in the upper floor

• Casement windows (bad), so no cross ventilation but for humidity it remains cool inside.

• Presently, single loaded corridor is there. Double loaded corridor can be there, as gaps in the middle can be utilized as interactive space.

• North side is the classroom which is very good

• Recessed windows are there with thick wall, which is good as thermal mass. Thus provide cool interior

• Because of the plantation in front of the dept, it keeps the inside cool

• Universal design

Page 39: campus analysis

WORKSHOP

GROUND FLOOR PLAN

Page 40: campus analysis

INFERENCE (WORKSHOP)• CLIMATE: The plan is made such, that it provides ventilation & light in the interior.

• BYELAWS- no fire safety norms

• BYELAWS: no plinth so differently able people can access

• AREA: electrical, carpentary and machine lab is fine. Welding lab need more space as clubs also work there.

• AREA: Per workshop departments 25 students.

• FUNCTION: The plan is a very simple one , we need to understand the user profile.

• FUNCTION: Machine shop too heavy, so need more maintenance. Big iron pieces used in the machine shop are cut in the welding shop.

• FUNCTION: The middle space is used as courtyard, but not properly maintained.

• FUNCTION: No plinth is there. They can have a separate entrance from where the model of cars can be taken out.

• FUNCTION: No chair is there inside, otherwise students will sit.

• FUNCTION: Should look at the building as a modular system

• PROXIMITY: with mechanical and chemical dept

• ECOLOGY:Palm trees are in front.

Page 41: campus analysis

MECHANICAL DEPARTMENTACADEMIC

BLOCK

GROUND FLOOR PLAN

FIRST FLOORPLAN

Page 42: campus analysis

MECHANICAL DEPARTMENTWORKSHOP

BLOCK

GROUND FLOOR PLAN

Page 43: campus analysis

MECHANICAL DEPARTMENTWORKSHOP

BLOCK

FIRST FLOOR PLAN

Page 44: campus analysis

INFERENCE (MECHANICAL DEPARTMENT)

• CLIMATE: needs proper ventilation and light, as it is worked with machines

• BYELAWS: No fire safety. Only one staircase is there to exit from the 1st floor.

• BYELAWS: not for differently able people

• AREA:Small room for the labs at the front side of building.

• AREA: Faculty rooms are very large with 1 faculty and 3 PhD scholars working.

• FUNCTION: Garage type door to facilitate large machines – large machine lab.

• FUNCTION: 1 faculty lab not getting any ventilation.

• FUNCTION: Production design lab is having double height , for the fumes need more space to escape.

• FUNCTION: Planning or landscaping required in big courtyard for interaction

• FUNCTION: Many courtyards are used as stores

• FUNCTION: some rooms which doesn’t requires light, can be places in the interior. Eg: xrayroom

• PROXIMITY: with central workshop and PPA. In front of it is the nescafe

• ECOLOGY: Ashoka tree in front.

Page 45: campus analysis

CHEMICAL DEPARTMENT

Page 46: campus analysis

CHEMICAL DEPARTMENT

Page 47: campus analysis

CHEMICAL DEPARTMENTINFERENCE• CLIMATE: a lot of glazing is put on the side which is getting

the direct sunrays.• CLIMATE: AC is required for the professors room west• BYELAWS: The staircase in South, may act as fire escape

staircase. • BYELAWS: Not for differently able people• AREA: The labs are huge, but they are not properly ventilated• FUNCTION: Unique in appearance. • FUNCTION: The staircase in the rare end is only till G+1, not

in the upper blocks• FUNCTION: Mostly labs are here in the department. • FUNCTION: The south part is till G+3. • FUNCTION: G+1 helps in ventilation in G+3. • FUNCTION: The courtyard is covered up so heat doesn’t

goes up, but because of the trees in front of the dept. , it provides good cool microclimate inside

• FUNCTION: Most classes are taken in L.A. • PROXIMITY: food and chemical department are together• PROXIMITY: With BMBT department• ECOLOGY: south side is shaded by trees.

Page 48: campus analysis

LECTURE ACADEMY

Page 49: campus analysis

LECTURE ACADEMY

Page 50: campus analysis

LECTURE ACADEMYINFERENCE :• FUNCTION: The common classes must be linked

with all the departments• FUNCTION: For a bigger room in LA, create much

more interaction by having projectors in the class• FUNCTION: Should have acoustical treatment• Lift should be with a lift room• FUNCTION: Courtyard is stepped, so can be made

much more interacting and interesting• Courtyard can have a water element to provide a

good micro climate, but pump it out during the humid months

• FUNCTION: Should have formal and informal interactive spaces

• FUNCTION: Furniture layout can be much more interesting

• No proper fenestration thus keeping the classroom hot and humid

• FUNCTION: A double heighted lobby space

Page 51: campus analysis

CERAMIC DEPARTMENT

Page 52: campus analysis

CERAMIC DEPARTMENT

INFERENCE :• Staircase very far away from each other. Dead end dist

more than 6mts• FUNCTION: Rooms are placed in such a way that spaces

are there in-between the rooms to provide light and ventilation

• Landing is not according to bye-laws in the front portion• Labs and professors cabin are in proximity so more

interacting• No landing before the door in front of the ramp• FUNCTION: Store spaces adjacent to the lab is interesting• Faculty rom blocking the path of the corridor• Toilet space is vey less• FUNCTION: The space in between the faculty room is

empty and is not of any use• FUNCTION: All the office block is in the ground floor-

good• FUNCTION: Eggcrate fenestration is good for the building• FUNCTION: Corridor in the south act as a buffer zone

Page 53: campus analysis

PPA

GROUND FLOOR PLAN

FIRST FLOOR PLAN

Page 54: campus analysis

INFERENCE (PPA)• FUNCTION: Entrance is not properly designed

• FUNCTION: This building can act as a good interactive space, which is not there

presently

• FUNCTION: We can provide a stage for much more interaction

• PROXIMITY: should be in proximity with BBA

• AREA: no proper seating space

Page 55: campus analysis

PLANNING AND ARCHITECTURE

GROUND FLOOR PLAN

Page 56: campus analysis

PLANNING AND ARCHITECTUREFIRST FLOOR

PLAN

INFERENCE:• FUNCTION: No plinth in front• FUNCTION: Previously was a high voltage lab turned to architecture dept.• FUNCTION: Office connected with HOD room thus no privacy• FUNCTION: 2 part of computer room, thus miscommunication between the students and teacher sometime• FUNCTION: Library not accessed from the corridor, and its very small in size• CLIMATE: Ground floor is cool but humid• FUNCTION: Faculty room no ventilation• FUNCTION: Kitchenate can be there as people stay whole night• FUNCTION: The classroom in upper floor should be big enough• FUNCTION: Exhibition gallery, lockers, loungh should be there and must be made more interesting and

interactive• PROXIMITY: in proximity with library,main building and mining dept. but should be close to civil dept• CLIMATE: bad plan as the longest side is facing east and west

Page 57: campus analysis

EC-EI DEPARTMENT

GROUND FLOOR PLAN

Page 58: campus analysis

EC-EI DEPARTMENT

FIRST FLOOR PLAN

Page 59: campus analysis

EC-EI DEPARTMENT

SECOND AND THIRD FLOOR PLAN

Page 60: campus analysis

INFERENCE (EC-EI DEPARTMENT)• FUNCTION: Double loaded corridor is fine as there is proper ventilation and lighting

• FUNCTION: Functionally the plan is fine

• FUNCTION: Basement cant be used as earth bumping but with proper water proofing

• The building is inclines at an angle of 27 degree from the normal

• FUNCTION: Proper ventilation to the courtyard is there, but its of no use as the top floor are having all glazing

• FUNCTION: Entrance height is double, so in summer sun rays are restricted while in winter the rays enter inside

• FUNCTION: Corner space have balcony from G+2

• FUNCTION: The whole building is symmetrical with the addition of high voltage lab in the electrical section

• BYELAWS: Universal design

• FUNCTION: Courtyard gets heated up as its fully cladded with tiles