Annex B3 Technical Offer Form Page 1 of 11 Technical Offer Form FOR ELECTRICAL AND LIGHTNING PROTECTION SYSTEM Bidders need to Submit complete catalogue and specification for the system with brand names and brochures. TECHNICAL DATA FOR SWITCHBOARDS, DISTRIBUTION BOARDS AND ACCESSORIES ITEM NO. DESCRIPTION OFFER A. SWITCHBOARDS 1 MSB & EMSB a. Manufacturer b. Country of Manufacture c. Colour finish d. Type of sheet metal Electro-galvanised steel sheets e. Design Ambient Temperature (40C) 2 SUB-SWITCHBOARD a. Manufacturer b. Colour Finish c. Enclosure required: Drip-proof natural ventilated d. Design Ambient Temperature (40C) 3 DISTRIBUTION BOARDS a. Manufacturer b. Colour Finish c. Enclosure required : Drip proof natural ventilated d. Design Ambient Temperature (40C) B. ELECTRICAL COMPONENTS 1 ACB a. Manufacturer / Origin b. Model / Type No. c. Rated Current / Voltage d. Short-time withstand current (3 sec) 2 MCCBS a. Manufacturer b. Model / Type No. c. Interrupting Capacity 3 MCB a. Manufacturer b. Model / Type No.

Annex B3 – Technical Offer Form - UNHCR

Embed Size (px)

Citation preview

Annex B3 – Technical Offer Form

Page 1 of 11

Technical Offer Form

FOR ELECTRICAL AND LIGHTNING PROTECTION SYSTEM – Bidders need to

Submit complete catalogue and specification for the system with brand names and

brochures.

TECHNICAL DATA FOR SWITCHBOARDS, DISTRIBUTION BOARDS AND ACCESSORIES

ITEM NO. DESCRIPTION OFFER

A. SWITCHBOARDS

1 MSB & EMSB

a. Manufacturer

b. Country of Manufacture

c. Colour finish

d. Type of sheet metal Electro-galvanised steel sheets

e. Design Ambient Temperature (40C)

2 SUB-SWITCHBOARD

a. Manufacturer

b. Colour Finish

c. Enclosure required: Drip-proof natural ventilated

d. Design Ambient Temperature (40C)

3 DISTRIBUTION BOARDS

a. Manufacturer

b. Colour Finish

c. Enclosure required : Drip proof natural ventilated

d. Design Ambient Temperature (40C)

B. ELECTRICAL COMPONENTS

1 ACB

a. Manufacturer / Origin

b. Model / Type No.

c. Rated Current / Voltage

d. Short-time withstand current (3 sec)

2 MCCBS

a. Manufacturer

b. Model / Type No.

c. Interrupting Capacity

3 MCB

a. Manufacturer

b. Model / Type No.

Annex B3 – Technical Offer Form

Page 2 of 11

c. Interrupting Capacity

Auxiliary Power Supply Voltage

4 SELECTOR SWITCHES

a. No. of Selection Positions (Ammeter)

b. No. of Selection Positions (Voltmeter)

5 INDICATING LAMPS

a. Manufacturer

b. Transformer operated type

c. Watt / Volts

6 PROTECTION RELAYS (OVERCURRENT & EARTH FAULT RELAY)

a. Manufacturer

b. Model No.

c. Type of Description

d. No. of poles

7 ELCB/RCCD

a. Manufacturer

b. Model / Type No.

c. Earth Leakage Sensitivity

8 EARTH FAULT RELAY (STATIC TYPE)

a. Manufacturer

b. Model No.

c. Type Description

d. No. of poles

9 EARTH LEAKAGE RELAY (ELR)

a. Manufacturer

b. Model / Type No.

c. Leakage current setting

d. Time delay setting range

10 CURRENT TRANSFORMERS

a. Manufacturer

b. Ratio

c. Class - Protection

d. Class - Metering

e. Rated Burden

11 CONTACTORS

a. Manufacturer

b. Model / Type No.

c. Duty Category

d. Peak switching current

12 SHORT CIRCUIT TYPE TESTS

Switched type manufactured type tested for short circuits of 50kA of 1 sec.

Annex B3 – Technical Offer Form

Page 3 of 11

TECHNICAL DATA FOR LV CABLES & CABLING INSTALLATIONS

ITEM NO. DESCRIPTION OFFER

1 LV CABLING :

1.1 PVC / PVC Cables

a) Manufacturer

b) Standards

c) Voltage Grade

d) Insulation Material

e) Multi-stranded copper conductors

1.2 XLPE / PVC Cables

a) Manufacturer

b) Standards

c) Voltage Grade

d) Insulation Material

e) Multi-stranded copper conductors

1.3 PVC/SWA/PVC Cables:

a) Manufacturer

b) Standards

c) Voltage Grade

d) Multi-stranded copper conductors

e) Galvanised Steel Wire Armoured

1.4 XLPE/SWA/PVC Cables :

a) Manufacturer

b) Standards

c) Voltage Grade

d) Multi-stranded copper conductors

e) Galvanised Steel Wire Armoured

1.5. Fire Resistant / MICC Cables:

a) Manufacturer

b) Material type

2 CABLING ACCESSORIES :

2.1 Cable Termination Glands:

a) Manufacturer

b) Type

c) State material used for gland

2.2 Cable Sockets / Lugs

a) Manufacturer

b) Method of Cable / Socket Connection

c) Material of Cable Socket

2.3 Cables Cores markers (slip-in type)

a) Manufacturer

Annex B3 – Technical Offer Form

Page 4 of 11

b) Type

c) Material used

2.4 Cable Sleeve Markers:

a) Manufacturer

b) Type

c) Material used

3 GI CONDUITS:

a) Manufacturer

b) Type

c) Material used

4 PVC PIPE:

a) Manufacturer

b) Type

c) Material used

5 CABLE TRUNKING:

a) Manufacturer

b) Type

c) Material used

d) Thickness

e) Standard length

6 CABLES LADDER:

a) Manufacturer Hot dipped galvanised

b) Material used

c) Thickness

d) Standard length

7 CABLES TRAYS:

a) Manufacturer Hot dipped galvanised

b) Material used

c) Thickness

d) Standard length

TECHNICAL DATA FOR LIGHTING, SWITCHES, SOCKET OUTLET, ETC)

ITEM NO. DESCRIPTION OFFER

1 2x4 LED Recessed/Surface Light Fitting c/w LED Tube

a) Name of Manufacturer

b) Model

c) Country of Manufacture

d) Lamp colour

e) Total watt

f) Dimension

2 Double Bare Channel Light Fitting with LED tube (normal/weatherproof type)

Annex B3 – Technical Offer Form

Page 5 of 11

a) Name of Manufacturer

b) Model

c) Country of Manufacture

d) Lamp colour

e) Total watt

f) Dimension

3 Single Bare Channel Light Fitting with LED tube (normal/weatherproof type)

a) Name of Manufacturer

b) Model

c) Country of Manufacture

d) Lamp colour

e) Total watt

f) Dimension

4 LED DOWNLIGHTER :-

a) Name of Manufacturer

b) Model

c) Country of Manufacture

d) Lamp colour

e) Total watt

f) Dimension

5 SWITCHES AND SWITCHES SOCKET OUTLET

5.1 Light Switches

a) Flush Lighting Switch

b) Flush Push Button Switch

c) Flush Dimmer Switch

d) Metalclad Lighting Switch

e) Grid Switch

f) Weather Proof IP56 Lighting Switch

g) Weather Proof IP56 Push Button Switch

h) Surface Mounted 230V 20A IP56 Switch

I) Surface Mounted 400V 20A to 60A IP56 Switch

5.2 Switched Socket Outlet

a) 13A Surface Flush Mounted S/S/O

b) 13A Surface Flush Mounted S/S/O c/w Pilot Light

c) 13A Metalclad Switched Socket Outlet

d) 15A Switched Socket Outlet

e) Weatherproof Switched Socket Outlet

6.1 EMERGENCY LIGHTING LUMINAIRE

a) Name of Manufacturer

b) Country of Manufacture

c) Local Agent

6.2 SELF-CONTAINED EMERGENCY KELUAR SIGN

a) Name of Manufacturer

Annex B3 – Technical Offer Form

Page 6 of 11

b) Country of Manufacture

c) Local Agent

d) Mode of Operation

e) Input Voltage

TECHNICAL DATA FOR LIGHTNING PROTECTION EQUIPMENT

ITEM NO. DESCRIPTION OFFER

LIGHTNING PROTECTION MATERIALS:-

1 COPPER TAPE:

a) Make

b) Model No.

c) Type

d) Material

2 ALUMINIUM TAPE:

a) Make

b) Model No.

c) Type

d) Material

3 SQUARE TAPE CLAMP

a) Make

b) Model No.

c) Type

d) Material

4 TEST CLAMP:

a) Make

b) Model No.

c) Type

d) Material

5 BI-METALLIC CONNECTOR:

a) Make

b) Model No.

c) Type

d) Material

6 ‘U’ BOLT ROD CLAMP :

a) Make

b) Model No.

c) Type

d) Material

7 EARTH POINT :

a) Make

b) Model No.

c) Type

d) Material

Annex B3 – Technical Offer Form

Page 7 of 11

8 CONCRETE INSPECTION EARTH CHAMBER

a) Make

b) Model No.

c) Dimension

d) Material

e) Size of Earth Bar

9 TAPE CLIP :

a) Make

b) Model No.

c) Type

d) Material

TECHNICAL DATA FOR EARTHING

ITEM NO. DESCRIPTION OFFER

1 EARTH POINT:

a) Make

b) Model No.

c) Type

d) Material

2 CONCRETE INSPECTION EARTH CHAMBER

a) Make

b) Model No.

c) Dimension

d) Material

e) Size of Earth Bar

3 EXOTHERMIC WELD :

a) Make

b) Type

c) Type of Weld Powders

4 CONDUCTOR (STRANDED COPPER CONDUCTOR)

a) Make

b) Type

c) Size

d) Strand (No. / Dia.)

e) Wt / kg

f) Model No.

5 25 x 3mm CU TAPE

a) Make

b) Type

c) Size

d) Wt / kg

e) Model No.

6 EARTH ROD:

Annex B3 – Technical Offer Form

Page 8 of 11

a) Make

b) Type

c) Model No.

d) Nom. Diameter

e) Length

TECHNICAL DATA FOR SURGE PROTECTION DEVICE (SPD)

A) POWER SURGE PROTECTOR FOR MAIN SWITCH BOARD (3-PHASE)

DESCRIPTION TECHNICAL

REQUIREMENT COMPLY / NOT COMPLY

1 Nominal voltage, Un 415V

2 Max. working voltage, Uc 475V

3 Mode of protection 7 Module, Full Mode

(L-N, L-E & N-E)

4 Max. discharge current, Imax (8/20µs) 80kA

(L-N / L-E / N-E)

5 Let - through voltage, Up

at 10kA (8/20µs), 20kV (1.2/50µs) < 1.8kV

at 5kA (8/20µs), 10kV (1.2/50µs) < 1.2kV

at 3kA (8/20µs), 6kV (1.2/50µs) < 950V

6 Response time < 25ns

7 Standard of compliance MS IEC 61643-11

8 Local compliance SIRIM QAS Test Certificate

Manufacture 'MALAYSIA BRAND' Certificate

9 Status of indication LED indicators

10 Type of termination Parallel

11 Type of arrester MARSA - MONOBLOCK / MOV

12 Warranty against manufacturing defects 2 years

B) POWER SURGE PROTECTOR FOR SUB SWITCH BOARD (3-PHASE)

DESCRIPTION TECHNICAL

REQUIREMENT COMPLY / NOT COMPLY

1 Nominal voltage, Un 415V

2 Max. working voltage, Uc 475V

3 Mode of protection 7 Module, Full Mode

(L-N, L-E & N-E)

4 Max. discharge current, Imax (8/20µs) 40kA

Annex B3 – Technical Offer Form

Page 9 of 11

(L-N / L-E / N-E)

5 Let - through voltage, Up

at 10kA (8/20µs), 20kV (1.2/50µs) < 1.8kV

at 5kA (8/20µs), 10kV (1.2/50µs) < 1.2kV

at 3kA (8/20µs), 6kV (1.2/50µs) < 950V

6 Response time < 25ns

7 Standard of compliance MS IEC 61643-11

8 Local compliance SIRIM QAS Test Certificate

Manufacture 'MALAYSIA BRAND' Certificate

9 Status of indication LED indicators

10 Type of termination Parallel

11 Type of arrester MARSA - MONOBLOCK / MOV

12 Warranty against manufacturing defects 2 years

C) POWER SURGE PROTECTOR FOR DISTRIBUTION BOARD (3-PHASE)

DESCRIPTION TECHNICAL

REQUIREMENT COMPLY / NOT COMPLY

1 Nominal voltage, Un 415V

2 Max. working voltage, Uc 475V

3 Mode of protection 7 Module, Full Mode

(L-N, L-E & N-E)

4 Max. discharge current, Imax (8/20µs) 20kA

(L-N / L-E / N-E)

5 Let - through voltage, Up

at 10kA (8/20µs), 20kV (1.2/50µs) < 1.7kV

at 5kA (8/20µs), 10kV (1.2/50µs) < 1.2kV

at 3kA (8/20µs), 6kV (1.2/50µs) < 950V

6 Response time < 25ns

7 Standard of compliance MS IEC 61643-11

8 Local compliance SIRIM QAS Test Certificate

Manufacture 'MALAYSIA BRAND' Certificate

9 Status of indication LED indicators

10 Type of termination Parallel

11 Type of arrester MARSA - MONOBLOCK / MOV

12 Warranty against manufacturing defects 2 years

Annex B3 – Technical Offer Form

Page 10 of 11

D) POWER SURGE PROTECTOR FOR DISTRIBUTION BOARD (SINGLE PHASE)

DESCRIPTION TECHNICAL

REQUIREMENT COMPLY / NOT COMPLY

1 Nominal voltage, Un 240V

2 Max. working voltage, Uc 275V

3 Mode of protection 3 Module, Full Mode

(L-N, L-E & N-E)

4 Max. discharge current, Imax (8/20µs) 20kA

(L-N / L-E / N-E)

5 Let - through voltage, Up

at 10kA (8/20µs), 20kV (1.2/50µs) < 1.7kV

at 5kA (8/20µs), 10kV (1.2/50µs) < 1.2kV

at 3kA (8/20µs), 6kV (1.2/50µs) < 950V

6 Response time < 25ns

7 Standard of compliance MS IEC 61643-11

8 Local compliance SIRIM QAS Test Certificate

Manufacture 'MALAYSIA BRAND' Certificate

9 Status of indication LED indicators

10 Type of termination Parallel

11 Type of arrester MARSA - MONOBLOCK / MOV

12 Warranty against manufacturing defects 2 years

E) POWER SURGE PROTECTOR FOR DISTRIBUTION BOARD (SINGLE PHASE)

DESCRIPTION TECHNICAL

REQUIREMENT COMPLY / NOT COMPLY

1 Nominal voltage, Un 240V

2 Max. working voltage, Uc 275V

3 Mode of protection 3 Module, Full Mode

(L-N, L-E & N-E)

5 Max. discharge current, Imax (8/20µs) 40kA

(L-N / L-E / N-E)

6 Let - through voltage, Up

at 10kA (8/20µs), 20kV (1.2/50µs) < 1.7kV

at 5kA (8/20µs), 10kV (1.2/50µs) < 1.2kV

at 3kA (8/20µs), 6kV (1.2/50µs) < 950V

7 Response time < 25ns

8 Standard of compliance MS IEC 61643-11

9 Local compliance SIRIM QAS Test Certificate

Annex B3 – Technical Offer Form

Page 11 of 11

Manufacture 'MALAYSIA BRAND' Certificate

10 Status of indication LED indicators

11 Type of termination Parallel

12 Type of arrester MARSA - MONOBLOCK / MOV

13 Warranty against manufacturing defects 2 years

F) POWER LINE SURGE PROTECTOR AT THE EQUIPMENT END

DESCRIPTION TECHNICAL

REQUIREMENT COMPLY / NOT COMPLY

1 Nominal voltage, Un 120Vac / 240Vac

2 Max. working voltage, Uc 130Vac / 275Vac

3 Mode of protection Full Mode

(L-N, L-E & N-E)

4 Max. load Current 13 Amps

5 Max. discharge current, Imax (8/20µs) 20kA

(L-N / L-E / N-E)

6 Let - through voltage, Up <300V

at 1kA (8/20µs), 2kV (1.2/50µs)

7 Working frequency 40-60 Hz

8 Standard of compliance MS IEC 61643-11

9 Local compliance SIRIM QAS Test Certificate Manufacture 'MALAYSIA BRAND' Certificate

10 Status of indication LED indicator

11 Type of termination Series

12 Type of arrester MARSA - MOV

13 Warranty against manufacturing defects 2 years

Supplier Name :