Upload
andra-richard
View
214
Download
0
Embed Size (px)
Citation preview
+Discussion on outliers
Information from Antonella Succurro – list of outliers Oleg – list of pathologies seen in monoCis phase scans
+LBA - digitizers LBA05 1 digitizer chan18-23 offset -25.5ns
LBA08 1 digitizer chan 32-35 offset -6.5ns
LBA10 1 digitizer chan 12-17 offset 9ns Large Tfit RMS 2.3ns Beam2
LBA25 1 digi chan 24-29 offset -25ns
LBA31 1 digi chan 42-47 offset -24.7ns
LBA37 1 digi chan 36-41 offset 21.9ns Tagged by Oleg MonoCis phase scan does not affect Tfit possible bad TTCRx address
LBA40 1 digi chan 18-23 offset 4ns Large Tfit RMS 1.2ns Beam 2
LBA56 chan 24-29 offset 35.4ns
LBA56 chan 36-41 offset -35.5ns
LBA60 chan 12-17 offset -25.5ns
+LBC – digitizers / drawers LBC03 chan 32-35 offset 4ns Tagged by Oleg
wrong time at few Dskews...
LBC10 chan 18-23 offset -5.9ns Tagged by Oleg stuck bit in dskew setting?
LBC11 chan 18-23 offset 3.3ns
LBC29 chan 0-11 offset -2.3ns
LBC29 chan 12-17 offset -10.9ns
LBC29 chan 18-47 offset -2.3ns
LBC30 chan 18-23 offset 6.3ns
LBC31 chan 12-17 offset -7.3ns
LBC33 all digis offset -4.4ns
LBC34 all digis offset -2.7ns
+EBC - digitizers EBC16 chan 30-35 12ns Large Tfit RMS
3.7ns Beam 2
EBC21 chan 20-23 -24.8ns
EBC33 chan 30-35 12ns Large Tfit RMS 3.5ns Beam 2
EBC56 chan 30-35 13ns Large Tfit RMS 3.9ns Beam 2
+Special pathologies
LBA29 chan 0-5 all the digi needs to be shifted amount not completely clear
due to large spread among Tfits. Possible take offset from channels 3,4,5 for beam which have Tfit~19.5 and small RMS,
but need a look, laser, monoCis with phase scan
LBA30 chan 12-14 (half digi!) could it be that it is full digi but the other half did not pass
some selections used to look at outliers? Under discussion with Antonella
+Single Channels with non zero Tfits LBA
LBA21 chan 19 Tfit RMS =2.1ns
LBA30 chan 5
LBA45 chan 29
LBA48 chan 23
LBA49 chan 23
LBA49 chan 32
Channel with less than 10 events for <Tfit> determination
+Single Channels with non zero TfitsLBC LBC49 chan 5
+Single Channels with non zero TfitsEBA EBA3 chan 1
EBA4 chan 1
EBA12 chan 1
EBA 13 chan 1
EBA 47 chan 6
EBA60 chan 1
EBA61 chan 1
+Single Channels with non zero TfitsEBC EBC12 chan 1
EBC13 chan 1
EBC18 chan 4 Large RMS 2.3ns
EBC36 chan 1
EBC37 chan 1
EBC46 chan 1
EBC55 chan6
EBC64 chan31 Large RMS 7ns
+Conclusion All offsets that are per digitizers or per module or per
channel that are not in Oleg's list of problematic digitizers have small RMS on Tfits. => UPDATE OFFLINE RESIDUALS
Others study further with Laser runs in the gap Physics runs monoCis with phase scans
Missing the outliers in standard format thus writing script for conversion the updated residuals should be updated tonight