Presents the user with actual light values, not electrical signals
Accommodates multiple measurement types and conditions
Stand-alone operation and via computer interface
Highest precision, accuracy and sensitivity Accessory input optics & detectors for a wide
range of radiometric & photometric applications LabView & ActiveX Development Kits
Optronic Laboratories Radiometers/Photometers
OL 730C Radiometer/Photometer
Uses any photodiode or photomultiplier
Optional HV for photomultipliers OL 730C-MUX multiplexers provides
up to 512 detectors Suitable for DC and moderately
modulated AC sources
OL 730D Radiometer/Photometer Uses DSP technology, eliminating many problems with
analog components Can be used with any detector, extending the
wavelength range to the far-IR and the sensitivity to photon counting
Measures DC, AC, highly modulated and pulsed sources
Optional Built-in programmable HV supply for photomultipliers
Built-in chopper control for IR measurements Extra memory provides fast measurements: down to
10s per data point for custom analysis, Microsoft ExcelTM compatible
Fast acquisition (pulse profiling) User can
select the integration time per datum
User can select the number of data points to be measured
Fast acquisition of LED Displays
LED display with the OL 730D
0.00E+00
2.00E-08
4.00E-08
6.00E-08
8.00E-08
1.00E-07
1.20E-07
1.40E-07
1.60E-07
0 0.05 0.1 0.15 0.2
Time [s]
Sig
nal
[A
]
LED display with the OL 730D
0.00E+00
2.00E-08
4.00E-08
6.00E-08
8.00E-08
1.00E-07
1.20E-07
1.40E-07
1.60E-07
0.120 0.122 0.124 0.126 0.128 0.130
Time [s]
Sig
nal
[A
]
0
0.2
0.4
0.6
0.8
1
No
rm
ali
zed
lu
min
ou
s i
nten
sit
y
0 20 40 60 80 100 Time [ms]
red phosphorgreen phosphorblue phosphor
Peak-to-peak sinusoidal
modulation is seen as flicker
Peak Luminance and Persistance
measurements as low as 10 microseconds
Fast acquisition of CRT Displays
Fast acquisition of LED Signal Arrays
-20
0
20
40
60
80
100
120
140
Lu
min
ou
s I
nten
sit
y [
Cd
]
0 0.5 1 1.5 2 Time [s]
with current limit end on - no limit side on - no limit
Progressive oscsillation seenwhen not current limited
100
110
120
130
140
Lu
min
ou
s In
ten
sity
[C
d]
1.5 1.55 1.6 1.65 Time [s]
with current limit end on - no limit side on - no limit
Averaging modulated sources
DC measurement gives true averaging of the light due to DSP technology
Computer Monitor
0.00E+00
2.00E-10
4.00E-10
6.00E-10
8.00E-10
1.00E-09
1.20E-09
0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2
Time [s]
Sig
nal
[A
]
Data logged every .1 ms
Average datum
Creating an Application
OL 600Telescope is looking at this test area
Data is downloaded to Excel™ Worksheet
Calculations are done in Excel™
Results are presented/graphed in Excel™
Excel™ is saved as a template so anyone can use it
Contact your Optronic Laboratories sales representative or our offices directly for more information.