STANDARDS COMPLIANCE (Those with italics are pending)
Safety/Environmental RoHS, UL810a, Chinese RoHS, IEC 60068-2-14, IP67, SAE J2464
Shock SAE J2464, IEC 60068-2-27 (TA1@50g, TA2@25g) ISO 16750-3 (4.2.2)
Vibration SAE J2380, ISO 16750-3 (Tables 12 & 14)
www.ioxus.com | [email protected]©2016 Ioxus, Inc 160418
FEATURESMade in USALarge diameter end terminalsIntegrated heat sinkNon-conductive end platesHighly configurable w/6 T-slotsFlexible mounting, any orientationIP6785°C Capability
APPLICATIONSHigh powerHigh rate cyclingHigh cycle life (>1,000,000 cycles)Low maintenance
MARKETSTransportation subsystemEngine startingRegen energy captureGrid/Power correctionUPS/Ride through powerWind turbine pitch controlHybrid energy storage
iMOD X-SERIES™ w/ TITAN HT
RETHINK POWER
Corporate HeadquartersNorth American Sales
18 Stadium Circle Oneonta, NY 13820, USA
Toll Free: [email protected]
TEL: 607-441-3500FAX: 607-433-9014
Ioxus (Shanghai) Clean Energy Technology Co.翱旭(上海)清洁能源技术有限公司
2616 Ascendas Plaza, 133 Tianyaoqiao RdXuhui District, Shanghai 200030, China电子邮件: [email protected]电话 : +86 13564250125
Ioxus Japan Co. LTD
1381-1 OkamotochoKusatsu-city, Shiga Pref
525-0044, [email protected]
TEL : +81-77-569-5106FAX: +81-77-569-5168
*Shown with optional CAN Monitoring Module
PRELIMINARY
ELECTRICAL\PART NUMBER iMOD016V200A23 iMOD032V100A23 iMOD048V066A23 iMOD064V050A23 iMOD080V040A23 iMOD096V033A23 iMOD112V028A23 iMOD128V025A23
Capacitance (F) [Min/Nom] 200/208 100/104 66/69 50/52 40/41 33/34 28/29 25/26Voltage (Rated/Surge) [VR/VS] 16.2/17.1 32.4/34.2 48.6/51.3 64.8/68.4 81.0/85.5 97.2/102.6 113.4/119.7 129.6/136.8DC ESR 10ms (mΩ) [Nom/Max] 1.5/1.8 3.0/3.6 4.5/5.4 6.0/7.2 7.5/9.0 9.0/10.8 10.5/12.6 12.0/14.4IEC DC ESR (mΩ) [Nom/Max] 2.0/2.7 4.1/5.4 6.1/8.1 8.2/10.8 10.2/13.5 12.2/16.2 14.3/18.9 16.3/21.6AC ESR(mΩ 1kHz) [Nom/Max] 1.1/1.5 2.3/3.0 3.4/4.5 4.6/6.0 5.7/7.5 6.8/9.0 8.0/10.5 9.1/12.0
Hi Pot Test Voltage 5000VAC
UL Max Operational Voltage (per UL810A) 2000VDC (per series string)
CYCLING (Calculated Values)Continuous Current (A) [20°Rise] TBD Current, Short Circuit (A) 10800Current, Peak [1s] (A) 1200THERMAL (Reference)Operational / Storage Range (°C) -40 to 85 °C / -40 to 85 °CResistance, Thermal (°C/W) [RTH] TBD TBD TBD TBD TBD TBD TBD TBDENERGY (Reference / Calculated using nominal values)
EMAX (Whr) [Min/Nom] 7.3/7.6 14.6/15.2 14.6/15.2 21.9/22.8 36.5/38.0 43.7/45.6 51.0/53.2 58.3/60.8
PHYSICAL (Nominal Values)H (mm) 224W (mm) 147L (mm) 117 204 284 365 445 526 606 687Mass (kg) 4.3 7.6 11.0 14.4 17.8 21.1 24.5 27.9Volume (L) 3.9 6.7 9.4 12.0 14.7 17.3 20.0 22.6Terminal Fastener Size / Max Torque M8/20Nm & M10/30Nm
LIFE (EOL Criteria) [Capacitance/IEC DC ESR] *Life is a provisional valueDC (10 Yr, 25°C, @VR) [F/mΩ] >160/<5 >80/<10 >52/<16 >40/<21 >32/<27 >26/<32 >22/<37 >20/<43Endurance (2000hr, 85°C, @VR) [F/mΩ] >160/<5 >80/<10 >52/<16 >40/<21 >32/<27 >26/<32 >22/<37 >20/<43Storage (2 yr, 70°C, @ 0V) [F/mΩ] >180/<4 >90/<8 >58/<12 >44/<16 >36/<20 >28/<24 >24/<28 >22/<32Cycle (1M Cyc, 25°C, @ VR-VR/2) [F/mΩ] >160/<5 >80/<10 >52/<16 >40/<21 >32/<27 >26/<32 >22/<37 >20/<43
1200F BASED PRODUCT SPECIFICATIONS
www.ioxus.com | [email protected]©2016 Ioxus, Inc 160418
ADDITIONAL TECHNICAL INFORMATIONProduct specification test and calculation methods are available: Ioxus Notes on Datasheet Specifacations Ioxus Test Proceedures for Customer Evaluations
HOW TO ORDERBASE PART NUMBER MONITORING OPTIONS
iMODvvvVcccA23 +-01B Analog Temperature
-02B Digital Temperature
-03B CAN
PRELIMINARY
ELECTRICAL\PART NUMBER iMOD016V333A23 iMOD032V166A23 iMOD048V0111A23 iMOD064V083A23 iMOD080V066A23 iMOD096V055A23 iMOD112V047A23 iMOD128V041A23
Capacitance (F) [Min/Nom] 333/350 166/175 111/116 83/87 66/70 55/58 47/50 41/43Voltage (Rated/Surge) [VR/VS] 16.2/17.1 32.4/34.2 48.6/51.3 64.8/68.4 81.0/85.5 97.2/102.6 113.4/119.7 129.6/136.8DC ESR 10ms (mΩ) [Nom/Max] 1.2/1.7 2.4/3.4 3.6/5.0 4.8/6.7 6.0/8.4 7.2/10.1 8.4/11.8 9.6/13.4IEC DC ESR (mΩ) [Nom/Max] 1.6/2.1 3.2/4.2 4.9/6.3 6.5/8.4 8.1/10.5 9.7/12.6 11.3/14.7 13.0/16.8AC ESR(mΩ 1kHz) [Nom/Max] 1.0/1.3 2.0/2.6 3.1/4.0 4.1/5.3 5.1/6.6 6.1/7.9 7.1/9.2 8.2/10.6
Hi Pot Test Voltage 5000VAC
UL Max Operational Voltage (per UL810A) 2000VDC (per series string)
CYCLING (Calculated Values)Continuous Current (A) [20°Rise] TBDCurrent, Short Circuit (A) 13500Current, Peak [1s] (A) 1900THERMAL (Reference)Operational / Storage Range (°C) -40 to 85 °C / -40 to 85°CResistance, Thermal (°C/W) [RTH] TBD TBD TBD TBD TBD TBD TBD TBDENERGY (Reference / Calculated using nominal values)EMAX (Whr) [Min/Nom] 12.2/12.8 24.3/25.5 36.5/38.3 48.6/51 60.8/63.8 72.9/76.5 85.1/89.3 97.2/102.1PHYSICAL (Nominal Values)H (mm) 224W (mm) 147L (mm) 150 258 366 474 582 690 798 906Mass (kg) 5.5 10.0 14.6 19.1 23.7 28.3 32.8 37.4Volume (L) 4.9 8.5 12.0 15.6 19.2 22.7 26.3 29.8Terminal Fastener Size / Max Torque M8/20Nm & M10/30Nm
LIFE (EOL Criteria) [Capacitance/IEC DC ESR] *Life is a provisional valueDC (10 Yr, 25°C, @VR) [F/mΩ] >266/<4 >132/<8 >88/<12 >66/<16 >52/<21 >44/<25 >36/<29 >32/<33Endurance (2000hr, 85°C, @VR) [F/mΩ] >266/<4 >132/<8 >88/<12 >66/<16 >52/<21 >44/<25 >36/<29 >32/<33Storage (2 yr, 70°C, @ 0V) [F/mΩ] >298/<3 >148/<6 >98/<9 >74/<12 >58/<15 >48/<18 >42/<22 >36/<25Cycle (1M Cyc, 25°C, @ VR-VR/2) [F/mΩ] >266/<4 >132/<8 >88/<12 >66/<16 >52/<21 >44/<25 >36/<29 >32/<33
2000F BASED PRODUCT SPECIFICATIONS
www.ioxus.com | [email protected]©2016 Ioxus, Inc 160418
ADDITIONAL TECHNICAL INFORMATIONProduct specification test and calculation methods are available: Ioxus Notes on Datasheet Specifacations Ioxus Test Proceedures for Customer Evaluations
HOW TO ORDERBASE PART NUMBER MONITORING OPTIONS
iMODvvvVcccA23 +-01B Analog Temperature
-02B Digital Temperature
-03B CAN
PRELIMINARY
ELECTRICAL\PART NUMBER iMOD016V500A23 iMOD032V250A23 iMOD048V166A23 iMOD064V125A23 iMOD080V100A23 iMOD096V083A23
Capacitance (F) [Min/Nom] 500/525 250/262 166/175 125/131 100/105 83/87Voltage (Rated/Surge) [VR/VS] 16.2/17.1 32.4/34.2 48.6/51.3 64.8/68.4 81.0/85.5 97.2/102.6DC ESR 10ms (mΩ) [Nom/Max] 1/1.6 2/3.1 3.1/4.7 4.1/6.2 5.1/7.8 6.1/9.4IEC DC ESR (mΩ) [Nom/Max] 1.4/1.8 2.8/3.6 4.1/5.4 5.5/7.2 6.9/9.0 8.3/10.8AC ESR(mΩ 1kHz) [Nom/Max] 0.9/1.3 1.8/2.6 2.7/4 3.6/5.3 4.5/6.6 5.4/7.9
Hi Pot Test Voltage 5000VAC
UL Max Operational Voltage (per UL810A) 2000VDC (per series string)
CYCLING (Calculated Values)Continuous Current (A) [20°Rise] TBD Current, Short Circuit (A) 15800Current, Peak [1s] (A) 2700THERMAL (Reference)Operational / Storage Range (°C) -40 to 85 °C / -40 to 85 °CResistance, Thermal (°C/W) [RTH] TBD TBD TBD TBD TBD TBDENERGY (Reference / Calculated using nominal values)EMAX (Whr) [Min/Nom] 18.2/19.1 36.5/38.3 54.7/57.4 72.9/76.5 91.1/95.7 109.4/114.8PHYSICAL (Nominal Values)H (mm) 224W (mm) 147L (mm) 180 330 474 618 762 906Mass (kg) 7 12 18 24 29 35Volume (L) 5.9 10.9 15.6 20.3 25.1 29.8Terminal Fastener Size / Max Torque M8/20Nm & M10/30Nm
LIFE (EOL Criteria) [Capacitance/IEC DC ESR] *Life is a provisional valueDC (10 Yr, 25°C, @VR) [F/mΩ] >400/<3.6 >200/<7.2 >132/<10 >100/<14 >80/<18 >66/<21Endurance (2000hr, 85°C, @VR) [F/mΩ] >400/<4.8 >200/<9.6 >132/<14.4 >100/<19.2 >80/<24 >66/<28.8Storage (2 yr, 70°C, @ 0V) [F/mΩ] >450/<2.7 >224/<5.4 >148/<8 >112/<10 >90/<13 >74/<16Cycle (1M Cyc, 25°C, @ VR-VR/2) [F/mΩ] >400/<3.6 >200/<7.2 >132/<10 >100/<14 >80/<18 >66/<21
3000F BASED PRODUCT SPECIFICATIONS
www.ioxus.com | [email protected]©2016 Ioxus, Inc 160418
ADDITIONAL TECHNICAL INFORMATIONProduct specification test and calculation methods are available: Ioxus Notes on Datasheet Specifacations Ioxus Test Proceedures for Customer Evaluations
HOW TO ORDERBASE PART NUMBER MONITORING OPTIONS
iMODvvvVcccA23 +-01B Analog Temperature
-02B Digital Temperature
-03B CAN
PRELIMINARY