23
Exergetic Systems ERRORS IN BOILER EFFICIENCY STANDARDS by Fred D. Lang, P.E. Exergetic Systems, Inc [email protected] ASME POWER2009-81221 For delivered paper (Rev. 27) visit: www.ExergeticSystems.com

0 Errors in Boiler Efficiency Stds

Embed Size (px)

DESCRIPTION

thermal boiler energy

Citation preview

Page 1: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

ERRORS IN BOILER EFFICIENCY

STANDARDS

by

Fred D. Lang, P.E.Exergetic Systems, Inc

[email protected]

ASME POWER2009-81221

For delivered paper (Rev. 27) visit:www.ExergeticSystems.com

Page 2: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Topics to be Discussed

The Old: n Where do we go ?n Why Absolute Standards ? n Review of PTC and European

The New: n Mechanics … Fuel Flow n Criticism n Applicabilityn Examples n Recommendations

Page 3: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Where do we go …

… is Boiler Efficiency arbitrary ?

Page 4: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

What one Vendor stated …

“I am well aware that the codes as they stand are arbitrary and can be manipulated, so it is certainly a case of Buyer Beware when it comes to bid evaluations by our Clients.”

Page 5: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Why Absolute Standards ?

n To Prove we understand the system … or not ! Do we understand basic conversion and QWF ?Do we understand the quantity of fuel required ?

n If standards only provide a “consistent basis forcomparison” then now can we freeze the referencetemperature at 77F, then determine HHV at 95F, usecombustion air at -10F, blow for soot, use constantpressure conversion, and hope to understand.

n 1% in boiler efficiency is worth ≈ $20 million for a Steam Generator supplying a 400 MWe unit.

Page 6: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

ASME PTC 4 and EN 12952-15

n ASME PTC 4 has replaced PTC 4.1n EN 12952-15 has replaced the British and

the German DIN-1942 with -BSI EN 12952-15:2003DIN EN 12952-15:2004.

n Heat Loss = Indirect = Energy Balance

n Input-Output = Direct = Gross Method

Page 7: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

ASME PTC 4 and EN 12952-15

n Reference temperature = 25C.n Corrections can be made to HHVs (EN). n Gross or net (PTC is weak, parallel in EN). n APH is included within boundary.n Heat Credits are set to zero (PTC), or in error (EN). n PTC: Energy Bal. 0B-HHV = 1.0 - 3Losses / HHVPn EN EB: 0B-HHV = 1.0 - 3Losses / (mAF HHVP + QG-Z ) n EN I-O: 0B-HHV = QWF / (mAF HHVP + QG-Z )n Corrections allowed to guarantee conditions. n Variance procedures.

Page 8: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Mechanics of the New

n TCal serves as the reference for all thermodynamicsGaseous Fuels: HHV are computed at TCal

Solid & Liquid: HHV are measured at TCal

n The Steam Generator boundary derives from theprinciple that thermal efficiency must onlyaddress how the as-fired fuel interacts withgas / air / working fluid.

Š MQT-Cal = - HHV Š MQT-Cal = - HHV

Page 9: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Mechanics of the New

HHV = - HPRIdeal-HHV + HRXCal-HHV - )Hv/p

HHVP = - HPRIdeal-HHV + HRXCal-HHV

HHVP + HBC = - HPRIdeal-HHV + HRXCal-HHV + HBCHHVP + HBC = - HPRIdeal-HHV + HRXAct-HHV

0B (HHVP + HBC) = - HPRIdeal-HHV + HRXAct-HHV - 3Losses0B (HHVP + HBC) = - HPRIdeal-HHV + HRXAct-HHV - 3Stack Losses - HNSL0B (HHVP + HBC) = - HPRAct-HHV + HRXAct-HHV - HNSL

0B = ( - HPRAct-HHV + HRXAct-HHV - HNSL ) / (HHVP + HBC) 0B = ( - HPRAct-HHV + HRXAct-HHV ) 0A / (HHVP + HBC) 0B = 0C 0A

Š MQT-Cal = - HHV Š MQT-Cal = - HHV

Page 10: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Firing Correction (HBC)

HBC = CP (TAF - TCal ) Fuel Fuel+ QSAH / mAF SAH+ WFD / mAF FD Fan+ [ (hAmb - hCal )Air

a (1.0 + ß)(1.0 + RRef ) NAir Comb. Air

+ (hg-Amb - hg-Cal )H2O bA (1.0 + ß) NH2O Moisture+ (hSteam - hf-Cal )H2O bZ NH2O In-Leakage+ CP (TAmb - TCal ) PLS bPLS

(1.0 + () NCaCO3 ] / (xNAF ) Limestone

Page 11: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Energy of Reactants (HRX)

Start with an ultimate analysis and a calorimetricdetermination of the fuel (HHV), record TCal

HPRIdeal-HHV = Ideal Products at TCal

HRXCal-HHV = (HHV + )HV/P) + HPRIdeal-HHV

Firing Correction (HBC) converts from TCal to the actual As-Fired: HRXAct-HHV = HRXCal-HHV + HBC

Page 12: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Energy of Products (HPR)

HPRAct-HHV-k = [ Heat of Formation at TCal plussensible heat (TStack - TCal ) ] k

Water is the key: Can not form water from combustion, referenced to)Hf

Cal , mix it with fuel water at TCal and then think itsOK to apply HHV at any other temperature. Water’senergy and MAF’s energy levels must be the same.The key is the HRXCal-HHV term.

HPRAct-HHV-H2O = [ Heat of Formation at TCal plussensible heat (hStack - hCal ); FuelWater; Air Moisture; Leakage ] H2O

Page 13: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Non-Chemistry & Non-Stack Losses

HNSL losses are only included if they affect computedfuel flow (i.e., affect the combustion process)

+ Radiation & Convention + Ash Pit and Fly and Bottom Ash terms+ Miscellaneous sensible heats- ID Fan

0A = 1.0 – HNSL / [- HPRAct-HHV + HRXAct-HHV ] 0B = 0C 0A

mAF = QWF / [ 0B (HHVP + HBC) ]

Page 14: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Criticism

Contribution to HHV from Ash and MAF:)HHV = (Fuel-Ash hT-Ash + (Fuel-MAF (– HPRIdeal + HRXCal )MAF

Contribution to HHV from Water:)HHV = (Fuel-H2 ()Ho

Vap–T – )hfg –T )H2O + (Fuel-H2O hT-H2O

EN 12952-15 (DIN 1942): HHVT = HHV25 + [ (:CP)MAF-Fuel + ((CP)Fuel-H2O

+ (:CP)dry-Air – (:CP)Stack-Gas – (:CP)Stack-H2O ] (T – 25)

) )

T

T

H0f - T = H0

f - 25 + Idh Compounds - 3Idh Elements 25 25

T

T

H0f - T = H0

f - 25 + Idh Compounds - 3Idh Elements 25 25

Page 15: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Applicability of the New

n Energy Balance is only allowed if: Fuel Water + Hydrogen > 10%.

n If Energy Balance, base tolerance on: Fuel sampling of ultimate analyses and HHVs Useful Energy Flow (QWF)

n If Energy Balance, calculation of fuel flow is required.n If Input-Output, base tolerance on:

Fuel sampling of ultimate analyses and HHVs Useful Energy Flow (QWF)Use an agreed TRef with an assigned range,

leading to a Firing Correction tolerance.

Page 16: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Example …n Say we are firing PRB in identical units in the Sahara

and in the Antarctic: both HHVs were determined at 77F, adjustmentsmade to produce the same losses, with differentFiring Corrections, units will have the sameefficiencies …

PTC 4 agrees & EN 12953-15 disagrees.

n Now, same fuel, but HHV determined at 34F & 120F: with no further adjustments, different HHVs willagain produce the same efficiencies …

PTC 4 disagrees & EN 12953-15 disagrees.

Page 17: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Fuel Flow, 640 MWe Coal-Fired

400

500

600

700

800

12:00 18:00 0:00 6:00

Fu

el F

low

s, lb

m/h

r

.

5000

6000

7000

8000

9000

Hea

tin

g V

alu

e, B

tu/lb

m

.

Input/Loss Fuel FlowPlant Indicated Fuel FlowInput/Loss Heating Value

Page 18: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Soot Blowing Flow Emulating a Tube Leak

0

5

10

15

20

25

30

18:00 20:00 22:00 0:00 2:00 4:00 6:00

So

ot

Blo

win

g F

low

(K

-lb

/hr)

.

Input/Loss Computed Soot Blowing FlowMeasured Soot Blowing

Page 19: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

H = f (C) for Powder River Basin

Hyd = -0.811119(Car) + 0.810615R2 = 0.772243

0.22

0.24

0.26

0.28

0.30

0.32

0.62 0.64 0.66 0.68 0.70 0.72

MAF Molar Carbon

MA

F M

ola

r D

iato

mic

Hyd

rog

en

POWDER RIVER BASIN

Page 20: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

OHC Approach for Interrogating Data

PRB Generic:Car+Hyd = -1.017100(Oxy) + 0.995391

R2 = 0.989902

0.91

0.92

0.93

0.94

0.95

0.96

0.03 0.05 0.07 0.09MAF Molar Oxygen

MA

F M

ola

r C

arb

on

+ D

iato

mic

Hyd

rog

en

.

POWDER RIVER BASIN (generic)Systems Effects Test 10-2005

Page 21: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

Recommendations for the New

n Proposal are 16 recommendations (review paper).n Reference temperature = Calorimetric temperature.n No corrections allowed to measured HHVs. n Gross or net efficiencies produce identical fuel flows. n APH is included within boundary. n Firing Corrections only affect Reactant streams. n Energy Balance allowed: fuel water + hydrogen > 10%

0B-HHV = (HPRAct – HRXAct) 0A / (HHVP + HBC) mAF = QWF / [0B-HHV (HHVP + HBC)]

n Input-Output required: fuel water + hydrogen < 10%0B-HHV = QWF / [mAF (HHVP + HBC)]

n Simple treatment of variances.

Page 22: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

From the 1890 Edition of Steam:

“Most of the abuses connected with steam engineering have arisen from two causes –avarice and ignorance:

avarice on the part of men who are imbued with the idea that cheap boilers and engines are economical, … andignorance on the part of those who claim to be engineers, but who at the best are mere starters and stoppers.”

Page 23: 0 Errors in Boiler Efficiency Stds

Exergetic Systems

To those who are notmere starters and stoppers,

Thank You.