Challenger 60/24 Overview This point to point IDU and ODU microwave full duplex radio system is a flexible, low-cost, The Challenger 60/24 is a low-cost point to point FDD/PDH digital microwave radio system for E1s or full duplex 10BaseT/100BaseTx Ethernet payload. The Challenger 60/24 Series products support capacities 0 to 24 El lines (N x 2.048 Mbps up to 50 Mbps), or Full Duplex Ethernet up to 62 Mbps and balance of its capacity in Full Du- plex Ethernet. See table below. The Challenger 60/24 operates in frequency ranges from 3.5 to 38 GHz. It is available in Non-Protected (1+0) and protected (1+1) mode in HSB, MHSB, frequency diversity (FD), and space diversity (SD), configurations. It is also configurable for repeater operation (East- West), ring operation or twice throughput as (2 + 0). It can be mounted directly on properly equipped antenna using our snap-on mount, or it can be mounted separately and connected using standard UBR flange series waveguide. The Challenger 60/24 meets carrier-grade standards for performance, reliability, and quality. * Higher Capacity value based on the smallest packet size (64 Bytes) Standards Compliance ETSI EN 302 217-2, ETSI EN 301 489, ETSI EN 300 132-2, IEC EN 60950 Wireless without Boundaries Features & Benefits Licensed Frequency Bands Point to Point Link Select 0, 4, 6, 8, 12, 16 or 24 E1s Up to 24 E1 Optional Capacity Low Latency Full Du- plex Ethernet (10/100 BaseT) to over 60 Mbps Field upgradeable by Plug-In Assembly RF, IF, Digital Loopback Capability Built-In BER Monitor Delay Setting for Hitless (errorless) Switching Wide Operating Tem- perature Range Wide DC Power Input Range and Low Power Consumption SNMP Network Man- agement Protocol Up to 300 meters Separa- tion between IDU and ODU Challenger Series Microwave System Indoor Unit Outdoor Unit F/B ETSI 0 to 24 E1s or up to 60+ Mbps Full Duplex Ethernet System Capacity Options: E1/Ethernet/NMS (QCPSK/8CPSK) * Capacity based on packet size 1522/64 Bytes System Capacity (Mbps) 8 12 16 25 34 60 # of E1s (N) 0-4 0-6 0-8 0-12 0-16 0-24 Used capacity by allo- cated E1s (Mbps) 8.20 12.90 17.20 25.80 34.37 52.56 # Ethernet Ports 2 2 2 2 2 2 Ethernet Capacity (Mbps) - No E1s 10.3/8.3 11.52 20.6/16.7 23.04 41.4/33.4 50/62* NMS (Mbps) 2.11 2.11 2.11 2.11 2.11 2.11

0 to 24 E1s or up to 60+ Mbps Full Duplex · PDF fileThis point to point IDU and ODU microwave full duplex radio system is a flexible, ... - Alarm Port Two Form C relay alarm outputs

  • Upload
    ledan

  • View
    215

  • Download
    1

Embed Size (px)

Citation preview

Page 1: 0 to 24 E1s or up to 60+ Mbps Full Duplex · PDF fileThis point to point IDU and ODU microwave full duplex radio system is a flexible, ... - Alarm Port Two Form C relay alarm outputs

Challenger 60/24 Overview This point to point IDU and ODU microwave full duplex radio system is a flexible, low-cost, The Challenger 60/24 is a low-cost point to point FDD/PDH digital microwave radio system for E1s or full duplex 10BaseT/100BaseTx Ethernet payload. The Challenger 60/24 Series products support capacities 0 to 24 El lines (N x 2.048 Mbps up to 50 Mbps), or Full Duplex Ethernet up to 62 Mbps and balance of its capacity in Full Du-plex Ethernet. See table below. The Challenger 60/24 operates in frequency ranges from 3.5 to 38 GHz. It is available in Non-Protected (1+0) and protected (1+1) mode in HSB, MHSB, frequency diversity (FD), and space diversity (SD), configurations. It is also configurable for repeater operation (East-West), ring operation or twice throughput as (2 + 0). It can be mounted directly on properly equipped antenna using our snap-on mount, or it can be mounted separately and connected using standard UBR flange series waveguide. The Challenger 60/24 meets carrier-grade standards for performance, reliability, and quality. 

* Higher Capacity value based on the smallest packet size (64 Bytes) Standards Compliance ETSI EN 302 217-2, ETSI EN 301 489, ETSI EN 300 132-2, IEC EN 60950

Wireless without

Boundaries

Features & Benefits • Licensed Frequency

Bands • Point to Point Link • Select 0, 4, 6, 8, 12, 16

or 24 E1s • Up to 24 E1 Optional

Capacity • Low Latency Full Du-

plex Ethernet (10/100 BaseT) to over 60 Mbps

• Field upgradeable by Plug-In Assembly

• RF, IF, Digital Loopback Capability

• Built-In BER Monitor • Delay Setting for Hitless

(errorless) Switching • Wide Operating Tem-

perature Range • Wide DC Power Input

Range and Low Power Consumption

• SNMP Network Man-agement Protocol

• Up to 300 meters Separa-tion between IDU and ODU

Challenger Series Microwave System

Indoor Unit Outdoor Unit F/B

ETSI

0 to 24 E1s or up to 60+ Mbps Full Duplex Ethernet

System Capacity Options: E1/Ethernet/NMS (QCPSK/8CPSK) * Capacity based on packet size 1522/64 Bytes

System Capacity (Mbps) 8 12 16 25 34 60

# of E1s (N) 0-4 0-6 0-8 0-12 0-16 0-24

Used capacity by allo-cated E1s (Mbps) 8.20 12.90 17.20 25.80 34.37 52.56

# Ethernet Ports 2 2 2 2 2 2

Ethernet Capacity (Mbps) - No E1s 10.3/8.3 11.52 20.6/16.7 23.04 41.4/33.4 50/62*

NMS (Mbps) 2.11 2.11 2.11 2.11 2.11 2.11

Page 2: 0 to 24 E1s or up to 60+ Mbps Full Duplex · PDF fileThis point to point IDU and ODU microwave full duplex radio system is a flexible, ... - Alarm Port Two Form C relay alarm outputs

KEY FEATURES • 1RU Standalone • Flexible Tx and Rx IF

to ODU • Standard Interfaces • Supports Custom-

ized NMS, SNMP

BENEFITS • Low Cost Means Bet-

ter Margins • Quick Time to Market • Network Option Cards

for Easy Upgrade and Expansion

• Easily Deployed and Activated

APPLICATIONS • Ethernet IP and/or • PDH Radio Networks • Cellular Backhaul • Trunking or Access

Networks

TURNKEY SOLUTIONS WNI Global will pro-

vide a complete solu-tion to your wireless requirements.

For more information

on any of our prod-ucts or services please visit us on the Web at:

www.wnint.com

Technical Information

Customer Network Data Interface Options

The Challenger 60 is a low-cost point to point FDD/PDH and IP digital microwave radio sys-tem for Ethernet or El payload. The Challenger 60 product supports capacities up to 62 Mbps Ethernet, any part of which can be allocated to El capacity up to 24xE1s The Challenger 60 operates in frequency ranges from 3.5 to 38 GHz. It is available in Non-Protected (1+0) and protected (1+1) mode in HSB, MHSB, frequency diversity (FD), and Space diversity (SD) configuration. The Model 60 is also configurable for Repeater Operation. It can be mounted directly on properly equipped antennas using our snap-on mount, or it can be mounted separately and connected using standard UBR flange series waveguide. The Challenger 60 meets carrier-grade standards for performance, reliability, and quality

Initial System Requirements

Physical - Ethernet Full duplex 100BaseTX - NxE1 Full Duplex E1 Connector - Ethernet RJ-45 - NxE1 2xRJ-48C, HD60 Compliance - Ethernet IEEE 802.3 - NxE1 ITU-T Auxiliary Connections - Alarm Port Two Form C relay alarm outputs Options - Additional Modem/IF for single chassis protected or east/west mode - E1 High Density Patch Panel

Network Interface Network Processor Modem Intermediate Frequency

Standard Configuration Scalable Ethernet 24x E1 Wayside or Traffic In-band Control Channel

Standard Configuration Flexible Platform Processor Security Built-in Web Server

Standard Configuration Flexible modulation: QCPSK / 8CPSK Equalization Pre-distortion Built-in Link Support: BER

Standard Configuration Transmit: 350 MHz Receive: 140 MHz

Protected 1+1 or 2+0 Option w/Combiner

Page 3: 0 to 24 E1s or up to 60+ Mbps Full Duplex · PDF fileThis point to point IDU and ODU microwave full duplex radio system is a flexible, ... - Alarm Port Two Form C relay alarm outputs

System Specifications

S ER V IC E S A VA I L ABL E

Technical Support

Installation and Setup

Maintenance

Application Support

Hardware Support

WNI Global, Inc. 3064 Scott Blvd. Santa Clara California USA 95054 Phone +1 408 982.9454 Fax +1 408 982.9456

Web: www.wniglobal.com Specifications and availability are subject to change without notice. Performance specifications are for 1+0 configurations and optimum conditions and may be affected by location, environment, and other operating conditions. ©2009-10, WNI Global, WNI-C60 Revised 022210

Description Specifications - Typical

Frequency Range (GHz) 3.5*/3.9 5.8 7 8 11 13 15 18 23 26 38* C *Consult factory for Availability Frequency Bands (GHz)

3.5* to 3.9

5.7 to

5.85

7.1 to 7.9

7.9to 8.5

10.7to

11.7

12.7to

13.3

14.5to

15.4

17.7to

19.7

22.0to

23.6

24.5 to

26.5

37.0to

39.5

Type Dual Conversion – Transmitter Power by Modulation Type

QCPSK 4/8/16 E1

8CPSK 6/12/24 E1

T-T Spacing (MHz) 7/14/28

Standard TX Power (dBm) 0 ~ +27 0 ~ +20 -10 ~ +27 -10 ~ +27 -10 ~+20 -10 ~ +20 -10 ~ +20 -10 ~ +19 -10 ~ +19 -10 ~ +19 -10 ~ +19High Xmit Power Opt. (dBm) 0 ~ +30 0 ~ +27 -10 ~ +27 -10 ~ +27 -10 ~ +23 -10 ~ +23 -10 ~ +23 -10 ~ +23 -10 ~ +23 -10 ~ +23 -10 ~ +23

Receiver Threshold @ 10E-6 BER

(dBm)

QCPSK

4 E1 -83 -83 -85 -85 -84 -83 -83 -83 -82.5 -82 -81 8 E1 -80 -80 -82 -82 -81 -80 -80 -80 -79.5 -79 -78

16 E1 -77 -77 -79 -79 -78 -77 -77 -77 -76.5 -76 -75

8CPSK

8 E1 -80 -80 -82 -82 -81 -80 -80 -80 -79.5 -79 -7816 E1 -77 -77 -79 -79 -78 -77 -77 -77 -76.5 -76 -7524 E1 -74 -74 -73 -73 -75 -71 -71 -70.5 -70 -70 -68.2

Frequency Stability ± 5 ppm ± 10 ppm

Peak Deviation ± 25 kHz ± 37.5 kHzSlew Rate 7.85 kHz/us

Maximum Receive Input Power 0 dBm Background BER < 10E-12 RSSI Accuracy ± 5 dB for -30 to -90 dBm and ± 2 dB for -35 to -80 dBm

Channel Flatness 2 dB, within ±43% of channel BW referenced from center frequency TX Spectrum Mask Per applicable ETSI* (for FCC output power is reduced by 2dB due to mask

Tx Power Accuracy over Command

Range (Max) ± 2.0 dB (max)

Output Power Muted < -50 dBm

Modulation QCPSK, 8CPSK

Output Return Loss > 10 dB > 6 dB (> 10 Opt.) Receiver

Receiver Noise Figure @ -65 dBm RSL (dB) 7.0 7.0 7.0 7.0 6.5 6.5 6.5 6.5 7.0 7.0 8.0

Typical Threshold* Meets ETSI Requirements CW Interferences* Meets ETSI Requirements

ODU InterfaceConnector Type N Type

Cable Impedance 50 OhmsTX IF Frequency 350 MHz RX IF Frequency 140 MHz

Primary PowerPower: Voltage / Consumption 20 – 72 VDC, either polarity / 25 Watts maximum for IDU + ODU (1+0) or 45 Watts maximum for Protected Terminal (1+1)

Protection Circuit Power and protected by IDU (inrush current – ETS 300 132-2) Physical ODU IDU

Dimensions (mm) 225 H x 225 W x 90 D 44 H x 436 W x 274 D Weight (Kg) 3.0 ~ 3.3 3.55 (1+0), 3.75 (1+1)

Environmental Operating Temperature Range -35°C to +65°C -5°C to +55°C Storage Temperature Range -40°C to +70°C -40°C to +70°C

Humidity 100% condensing (all weather) 95% non-condensing Elevation 4.570 meters (15k ft.) 4.570 meters (15k ft.)

OtherOperating ETS 300 019-2-4 Class 4M5 to (-33 +55°C)

Cold Start Conditions Power Supply Operational @ -45°C, ODU will transmit, no guarantee of quality of service. Storage ETS 300-019-2-1

Transport ETS 300-019.2-2 Finish (Corro-Coat PE 71-190Z (Powder Coat), Gloss White ODU

Ground Lug M5 x .8 x 9.5 long Alarms 2 x Form C (software-selectable dry contacts)

Systems Configurations Non-protected (1+0), Protected (1+1), Space Diversity (SD), Frequency Diversity (FD), Twice Throughput (2+0) and Repeater (East-West) Antenna Interface

(WG Flange) Type N Type N UBR84 UBR84 UBR100 UBR140 UBR140 UBR220 UBR220 UBR220 UBR320