    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    1

    1 Nokia Siemens Networks CN34012EN32GLN2

    MSS,GCS&CDSMSS,GCS&CDS ArchitectureArchitecture

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    2/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    2

    2 Nokia Siemens Networks CN34012EN32GLN2

    Objectives

    After completing this module, the student should be able to:

    Mention connectivity of Network Elements in Release 4List the main functions of the MSS, MSSu, GCS and CDS

    Explain the main functions of each functional unit

    List the redundancy principles for the units in MSS, MSSu,

    GCS and CDS

    Explain the main difference between the standalone MSS

    and integrated MSS

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    3/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    3

    3 Nokia Siemens Networks CN34012EN32GLN2

    Network Elements in Rel4

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    4/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    4

    4 Nokia Siemens Networks CN34012EN32GLN2

    MSS, MSSu & GCS

    MSS

    Standalone MSS: New delivery from M12 onwards Integrated MSS : Same as current MSCi

    MSSu

    Upgraded from the operators current MSCi, removing units handling

    user plane.

    GCS

    A compact standalone Gateway Control Server , does not have BSU &

    VLRU (Transit switch functionality).

    CDS New delivery from M12 onwards. Used for circuit switched data calls

    along with standalone MSS.

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    5/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    5

    5 Nokia Siemens Networks CN34012EN32GLN2

    New Hardware Introduced in M14

    Ethernet Message Bus (EMB)

    ESB14-A

    GSWB2k

    ET16 and ETS2

    New Mass Memory- Blu-Ray DVD

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    6/45

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    7/45

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    8/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    8

    8 Nokia Siemens Networks CN34012EN32GLN2

    Hardware Architecture for Integrated MSS/GCS

    CDSU

    TGFP

    BDCUPAUMCCSUBSUMFSUCASU

    CHU OMUSTUVLRUCMCMU

    PSTN

    PBX

    NSS

    BSS

    LAN LAN LAN

    VDU and LPT

    X.25

    ET

    GSW

    CCMU

    MESSAGE BUS

    ET

    ET

    ECET

    CLSEXT.

    SYNC

    VANG

    O&M LAN Switch

    IPET

    LAN

    IP Trunk

    TGSU

    IP

    IP Control PlaneLAN Switch

    IP User PlaneLAN Switch

    The BSU and VLRU are partof the Integrated MSS,not the GCS.

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    9/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    9

    9 Nokia Siemens Networks CN34012EN32GLN2

    Operating Principles for CDS

    BSS/RAN PSTN/ISDN

    MGWMGW

    MSSMSS

    CDSCDS

    CDSU

    H.248/Megaco

    IWF control

    interface

    TDM/PCM

    Ta Tb

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    10/45

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    11/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    11

    11 Nokia Siemens Networks CN34012EN32GLN2

    New Standalone MSS/GCS Cabinets in M14

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    12/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    12

    12 Nokia Siemens Networks CN34012EN32GLN2

    MSS and CDS floor layout

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    13/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    13

    13 Nokia Siemens Networks CN34012EN32GLN2

    MSSu Cabinets in M14

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    14/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    14

    14 Nokia Siemens Networks CN34012EN32GLN2

    Integrated MSS/GCS Cabinets

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    15/45

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    16/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    16

    16 Nokia Siemens Networks CN34012EN32GLN2

    Functional UnitsFunctional Units

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    17/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    17

    17 Nokia Siemens Networks CN34012EN32GLN2

    Ethernet-based Message BusEMB

    The Ethernet-based Message Bus (EMB) enables higher capacity and reducedfootprint in the MSS and the HLRi.

    The LAN topology used in the EMB is a switched LAN. Each computer has apoint-to-point connection to a cabinet level LAN switch, ESB26 or compatible.

    These LAN switches are further connected to a second stage LAN switch,ESB14-A or compatible. All connections are full duplex.

    ESB14-A is used as second level Ethernet switch to enable the interconnectionbetween first level Ethernet switches in EMB configurations.

    ESB14-A is a 14-port managed Ethernet switch integrated into the M98mechanics. ESB14-A has 10 optical gigabit Ethernet ports

    The speed of links between computers and cabinet level LAN switches is 100Mbps and the speed of links connecting the cabinet level LAN switches to thesecond stage LAN switches is 1 Gbps.

    The EMB requires the use of CP816-A or compatible processor plug-in units,

    which have four Ethernet ports. Two ports are used for EMB LANs and two ports forexternal LANs. The EMB LANs are totally separated from the external LANs.

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    18/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    18

    18 Nokia Siemens Networks CN34012EN32GLN2

    Ethernet-based Message BusEMB

    100Mbps

    1Gbps

    ESB26

    OMU,1OMU,0CCSU,2CCSU,1CCSU,0

    ESB26

    H LR U, 0, 0 H LR U, 0, 1H LR U, 1, 0 H LR U, 1, 1

    1Gbps

    100Mbps

    EMB,0

    EMB,1

    Second s t a ge sw i t ch

    Cab ine t leve l

    sw i t che s

    Compu t e r s

    ESB14-A

    ESB14-A

    ESB26 ESB26

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    19/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    19

    19 Nokia Siemens Networks CN34012EN32GLN2

    Cabinet in MSS/GCS:14AC

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    20/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    20

    20 Nokia Siemens Networks CN34012EN32GLN2

    Central Memory and Marker (CMM)

    Function: CMM contains the functionality

    of the CM, Marker (optional), and CCMUin

    the same functional unit.

    Redundancy: 2n

    CMM in a DC3C-B cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    21/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    21

    21 Nokia Siemens Networks CN34012EN32GLN2

    Cellular Management Unit (CMU)

    Function:The CMU controls the cellular

    radio network.

    Redundancy: 2n

    CMU in a DC4C-B cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    22/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    22

    22 Nokia Siemens Networks CN34012EN32GLN2

    Statistical Unit (STU)

    Function:The STU collects raw traffic

    measurements, supervises the load of the

    exchange, maintains various counters andproduces statistical reports.

    Redundancy: 2n

    STU in a MC2C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    23/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    23

    23 Nokia Siemens Networks CN34012EN32GLN2

    Charging Unit (CHU)

    Function:The CHU collects charging data,

    maintains various counters and produces

    detailed charging records.

    Redundancy: 2n

    CHU in a MC2C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    24/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    24

    24 Nokia Siemens Networks CN34012EN32GLN2

    Operation and Maintenance Unit (OMU)

    Function:

    handles all centralised supervision, alarm and

    recovery functions

    handles the connections towards user interface.

    The connections are made using IP network or via

    V.24 interface.

    collects the wired alarms from the exchange as well

    as from the external equipment connected to the

    system.

    has dedicated storage devices, which serve as a

    storage for the entire system software of the network

    element as well as for the event buffer for

    intermediate storing of alarms.

    Redundancy: 2n

    OMU in a CC4C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    25/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    25

    25 Nokia Siemens Networks CN34012EN32GLN2

    Basic Data Communication Unit (BDCU)

    Function:The BDCU provides

    communication links to the operation and

    maintenance network, to the SMS Centerand to the Billing Center.

    The BDCU provides the following external

    interfaces:

    analog X.25

    digital X.25

    LAN/Ethernet

    Redundancy: n

    BDCU in MC2C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    26/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    26

    26 Nokia Siemens Networks CN34012EN32GLN2

    Clock System (CLS) 1/2

    CLSU

    CLBU CLBUCLBU CLBU

    CLS includes CLSU (Clock System Unit) and CLBU (Clock and Alarm Buffer Unit)

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    27/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    27

    27 Nokia Siemens Networks CN34012EN32GLN2

    Clock System (CLS) 2/2

    Clock System Unit (CLSU)

    Function:

    The CLSU generates the clock and synchronization signals

    and transmits them further to the CLBU units in the other

    cabinets.

    The CLSU also collects the wired alarms from the units in the

    14AC and send them further to the OMU.

    Redundancy:2n

    Clock and Alarm Buffer Unit (CLBU)

    Function:

    The CLBU distributes the clock and synchronisation signals

    within the same cabinet.

    The CLBU also collects the wired alarms from the units

    whose timing it handles and transfers them to the OMU.

    Redundancy:2n

    Two independent

    CLSUs in a CLOC-B

    cartridge

    Two independent

    CLBUs in a CLAC-B

    cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    28/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    28

    28 Nokia Siemens Networks CN34012EN32GLN2

    LAN Switch Unit (SWU)

    Function:

    collects signalling data from the BSUs,

    CCSUs, SCPUs and SIGUs and sends itfurther to the IP network via external LAN

    switches and routers with a uplink

    connection.

    collects O&M signalling data from the

    OMU, BDCUs and STU/CHU units and

    sends it further to the IP network via

    external LAN switches and routers with a

    uplink connection.

    In M14 system level, the LAN switch units

    are also used in Ethernet Based Message

    Bus.

    Redundancy: 2nSWU in LASWC-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    29/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    29

    29 Nokia Siemens Networks CN34012EN32GLN2

    Visitor Location Register Unit (VLRU)

    Function:The VLRU contains information

    of each subscriber currently served by the

    MSC Server.

    Redundancy: 2n

    VLRU in a MC2C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    30/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    30

    30 Nokia Siemens Networks CN34012EN32GLN2

    Signalling Unit (SIGU)

    Function:The SIGU has the functionality of

    the CCSU, except that the SIGU can utilise

    only an IP-based signalling network.

    Redundancy: n+1

    SIGU in a MC2C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    31/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    31

    31 Nokia Siemens Networks CN34012EN32GLN2

    Base Station Signalling Unit (BSU)

    BSU in a MC2C-A cartridge

    Function:

    The BSU provides BSSAP and RANAP

    protocols that perform the signalling

    functions between radio networks and

    MSS.

    The BSU has SIGTRAN functionality. If

    the A-interface is connected directly to the

    Integrated MSS, then the BSU also

    controls the TDM lines.

    Redundancy: n+1

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    32/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    32

    32 Nokia Siemens Networks CN34012EN32GLN2

    Cabinet in MSS/GCS:14BC

    Note: 14 BC has the similar functional units in 14AC, and there is an option to installed

    Indirect Access Unit (INDU) in 14BC.

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    33/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    33

    33 Nokia Siemens Networks CN34012EN32GLN2

    Indirect Access Unit (INDU)

    Function:The INDU enables an indirect

    connection for such service providers, which

    do not have their own physical subscribercircuits to the exchange.

    Redundancy: 2n

    INDU in MC2C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    34/45

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    35/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    35

    35 Nokia Siemens Networks CN34012EN32GLN2

    Common Channel Signalling Unit (CCSU)

    Function:

    handles CCS7 signalling functions towards

    both PSTN and the other network elements

    in the SCN. CCS7 signalling traffic can be

    carried over both PCM lines (TDM) and the

    IP network with SIGTRAN.

    handles MEGACO (Media Gateway

    Control) signalling.

    controls the PCMs running to both PSTN

    and the other network elements in the SCN.

    Redundancy: n+1

    CCSU in DC3C-B cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    36/45

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    37/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    37

    37 Nokia Siemens Networks CN34012EN32GLN2

    Exchange Terminal- ET16 & ETS2

    Function:The ET performs the electrical

    synchronization and adaptation of an

    external TDM line. It is able to do theHDB3/AMI/B8ZS coding and decoding,

    insert the alarm bits in the outgoing

    direction, and produce the PCM frame

    structure.

    ET16: provides 16 E1 interfaces

    ETS2: provides 2 STM-1 interfaces

    Redundancy: n ETS2 & ET16 in GTIC

    cartridge

    ETS2 ET16

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    38/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    38

    38 Nokia Siemens Networks CN34012EN32GLN2

    Special Units in MSSu

    Channel Associated Signalling Unit (CASU)

    Primary Rate Access Unit (PAU)

    Multi Frequency Signalling Unit (MFSU)

    Echo cancelling and exchange terminal (ECET)

    Compact Data Service Unit (CDSU)

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    39/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    39

    39 Nokia Siemens Networks CN34012EN32GLN2

    Channel Associated Signalling Unit (CASU)

    Function:The CASU is installed in the

    network element only when Channel

    Associated Signalling (CAS) is neededbetween the Transit MSCi and the PSTN.

    Redundancy: n+1

    CASU in a CC3C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    40/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    40

    40 Nokia Siemens Networks CN34012EN32GLN2

    Primary Rate Access Unit (PAU)

    Function:The PAU performs the call control

    and signalling for the traffic of the ISDN

    PABX connected to DX 200 system.

    Redundancy: n+1

    PAU in a CC3C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    41/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    41

    41 Nokia Siemens Networks CN34012EN32GLN2

    Multi Frequency Signalling Unit (MFSU)

    Function:

    handles the receipt and transmission of R2

    or ANSI MF signals (the main control unit is

    CASU).

    continuity checking, conference call control

    and identification of push-button dialling.

    Redundancy: n+1/L

    MFSU in CC3C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    42/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    42

    42 Nokia Siemens Networks CN34012EN32GLN2

    Echo Cancelling and Exchange Terminal (ECET)

    Function: The ET with echo canceller

    is used for terminating TDM lines

    connected directly to Integrated MSS

    or Integrated GCS from PSTN or PBX.

    Redundancy: n

    EC2ET plug-in units in an

    ET4C-B / ET4C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    43/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    43

    43 Nokia Siemens Networks CN34012EN32GLN2

    Compact Data Service Unit (CDSU)

    Function: The main task of the CDSU

    is to adapt the data connection of the

    terminal device (i.e. laptop PC) of the

    GSM Mobile Station (MS) to PSTN or

    ISDN.

    Redundancy: n

    CDSU General Pool in a DS1C-B/DS1C-A cartridge

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    44/45CN34012EN32GLN2

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    44

    44 Nokia Siemens Networks CN34012EN32GLN2

    Redundancy

    2NVLRU

    2NSWU

    2NSTU

    N+1SIGU

    N+1SCPU

    N+1PAU

    2NOMU

    2NMB

    2NINDU

    NET

    2NEMB

    2NCMU

    2NCMM

    2NCM

    2NCHU

    N+1CCSU

    2NCCMU

    N+1BSU

    NBDCU

    RedundancyUnit

  • 8/12/2019 02 02 Cn34012en32gln2 Msc Server

    45/45

    MSC Server, Gateway Control Server and Circuit Seitched Data

    Server Architecture

    45 Nokia Siemens Networks CN34012EN32GLN2

    Capacity in M14