FlexiPacket Hub 800
R2.5
IDU Accessories Product Description
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
Nokia Siemens Networks is continually str iving to reduce the adverse environmental effects of
its products and services. We would like to encourage you as our customers and users to join
us in working towards a cleaner, safer environment. Please recycle product packaging and
follow the recommendations for power use and proper disposal of our products and their
components.
If you should have questions regarding our Environmental Policy or any of the environmental
services we offer, please contact us at Nokia Siemens Networks for any additional information.
8/10/2019 05 Idu Accessories Product Description
2/40
2 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product Description
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMEN-
TATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT,
INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT
LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR
THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2013. All rights reserved.
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources
of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle
this product and only after having carefully read the safety information applicable to this
product.
The safety information is provided in the Safety Information section in the Legal, Safety
and Environmental Information part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt knnen Gefahren durch Laser, Elektrizitt, Hitzeentwicklung oder
andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch
geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-
anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter Sicherheitshinweise im Teil Legal,
Safety and Environmental Information dieses Dokuments oder dieses Dokumentations-
satzes.
8/10/2019 05 Idu Accessories Product Description
3/40
8/10/2019 05 Idu Accessories Product Description
4/40
4 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product Description
6.2 Key characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
7 Dual-IDU accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7.1 Dual-IDU shroud. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
7.2 Dual-IDU protection panel and optical splitter. . . . . . . . . . . . . . . . . . . . . 36
7.2.1 Protection panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.2.2 Optical splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.3 Dual-IDU power injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
8 FPH800 installation tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
9 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
8/10/2019 05 Idu Accessories Product Description
5/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
5
IDU Accessories Product Description
List of FiguresFigure 1 WEEE label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 2 CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Figure 3 MEF certified compliant logo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Figure 4 16-port E1/T1 Multi-Service card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Figure 5 4-port GE RJ-45 card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 6 4-port GE SFP card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 7 2-port Power Injector card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 8 2-port FlexBus card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 9 2-port STM-1/4 MSC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 10 Electrical SFP module application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 11 Optical SFP module application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 12 GE electrical interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Figure 13 75 ohm Coaxial Cable with MDR68 connectors . . . . . . . . . . . . . . . . . . 24Figure 14 32 pair 120 ohm cable with MDR68 connectors . . . . . . . . . . . . . . . . . . 25
Figure 15 FB cable application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Figure 16 Power supply interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Figure 17 Grouding cable assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 18 RJ45 patch panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 19 CC4 patch panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 20 BNC patch panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 21 USB key connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 22 Dual-IDU shroud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 23 Backplane of the shroud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 24 A protection panel with 2 optic splitters . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 25 Optic splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 26 Power injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
8/10/2019 05 Idu Accessories Product Description
6/40
6 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product Description
List of TablesTable 1 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 2 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 3 List of symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 4 16-port E1/T1 Multi-Service card cabling . . . . . . . . . . . . . . . . . . . . . . . . 13
Table 5 4-port GE RJ-45 cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 6 4-port SFP card cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 7 2-port Power Injector card cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 8 2-port FlexBus Card cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 9 2-port STM-1/4 MSC card cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Table 10 GE/FE electrical interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 11 Property of GE copper cable reel with length = 5 m . . . . . . . . . . . . . . . 19
Table 12 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 13 Properties for MM fiber patch cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 14 Properties for SM fiber patch cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 15 E1/T1 interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 16 Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 17 FB cable and connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 18 Power supply interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 19 Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 20 Color code of power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 21 RJ45 patch panel characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 22 CC4 patch panel characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 23 BNC patch panel characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 24 Mechanical dimension and interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 25 USB key connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 26 Read/Write performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Table 27 Environmental specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 28 Shroud characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Table 29 Protection panel characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 30 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
8/10/2019 05 Idu Accessories Product Description
7/40
8/10/2019 05 Idu Accessories Product Description
8/40
8 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionPreface
1.4 Symbols and conventions
The following symbols and mark-up conventions are used in this document:
Representation Meaning
fDANGER!
fWARNING!
fCAUTION!
A safety message indicates a dangerous situation where
personal injury is possible.
The keywords denote hazard levels with the following meaning:
DANGER!- Indicates a hazardous situation which, if not
avoided, will result in death or serious (irreversible) personal
injury.
WARNING!- Indicates a hazardous situation which, if not
avoided, could result in death or serious (irreversible) personal
injury.
CAUTION! - Indicates a hazardous situation which, if not
avoided, may result in minor or moderate (reversible) personal
injury.
wNOTICE: A property damage message indicates a hazard that may resultin equipment damage, data loss, traffic interruption, and so on.
g A note provides important information related to the topic, forexample, not obvious exceptions to a rule or side effects.
t A tip provides additional information related to the topic which isnot essential in the context, but given for convenience.
Bold
All names of graphical user interface (GUI) objects, such aswindows, field names, buttons, and so on.
Example: Select the Full Screencheck box and press OK.
Terms and abbreviations which are linked to an entry in the
glossary and list of abbreviations respectively
Important key words
Italic Files, folders, and file system paths.
Example:/usr/etc/sbin/ftpd.exe
Emphasized words
typewriter Input to be typed in a command line or a GUI field.
Examples:
ping -t 192.168.0.1
Enter Worldin the Domainfield.
Output from a command, error messages, content of a status
line, and so on
File content, such as program sources, scripts, logs, and
settings
Placeholders, for example as part of a file name or field value.
Examples:
.pngor :
Table 3 List of symbols and conventions
8/10/2019 05 Idu Accessories Product Description
9/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
9
IDU Accessories Product Description Preface
Screenshots of the graphical user interface are examples only to illustrate principles.
This especially applies to a software version number visible in a screenshot.
1.5 Waste electrical and electronic equipment (WEEE)
All waste electrical and electronic products must be disposed of separately from the
municipal waste stream via designated collection facilities appointed by the government
or the local authorities. The WEEE label (see Figure 1) is applied to all such devices.
Figure 1 WEEE label
The correct disposal and separate collection of waste equipment will help prevent poten-
tial negative consequences for the environment and human health. It is a precondition
for reuse and recycling of used electrical and electronic equipment.
For more detailed information about disposal of such equipment, please contact Nokia
Siemens Networks.
The above statements are fully valid only for equipment installed in the countries of the
European Union and is covered by the directive 2002/96/EC. Countries outside the
[square brackets] A key to be pressed on a PC keyboard, for example [F11].
Keys to be pressed simultaneously are concatenated with a +
sign, for example [CTRL]+[ALT]+[DEL].
Keys to be pressed one after another are concatenated with
spaces, for example [ESC] [SPACE] [M].
> The greater than symbol > is used to concatenate a series of
GUI items in order to depict a GUI path. This is an abridged pre-
sentation of a procedure to be carried out in order to perform an
action or display a window or dialog box.
Examples:
A simple menu path: File> Save as ...
A more complex GUI path:SURPASS TransNetwindow > Toolsmenu >
3R-Matrix Report command > 3R-Matrix Reportdialog box
x
(in card names)
For convenience, card names are sometimes listed with a lower
case x variable, in order to concisely represent multiple cards.
Example:
I01T40G-x (is to be interpreted as I01T40G-1 and I01T40G-2)
Representation Meaning
Table 3 List of symbols and conventions (Cont.)
8/10/2019 05 Idu Accessories Product Description
10/40
10 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionPreface
European Union may have other regulations regarding the disposal of electrical and
electronic equipment.
1.6 RoHS complianceFlexiPacket Hub 800 complies with the European Union RoHS Directive 2002/95/EC on
the restriction of use of certain hazardous substances in electrical and electronic equip-
ment.
The directive applies to the use of lead, mercury, cadmium, hexavalent chromium, poly-
brominated biphenyls (PBB), and polybrominated diphenylethers (PBDE) in electrical
and electronic equipment put on the market after 1 July 2006.
Materials usage information on Nokia Siemens Networks Electronic Information
Products imported or sold in the Peoples Republic of China
FlexiPacket Hub 800 complies with the Chinese standard SJ/T 11364-2006 on the
restriction of the use of certain hazardous substances in electrical and electronic equip-ment. The standard applies to the use of lead, mercury, cadmium, hexavalent chro-
mium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE) in
electrical and electronic equipment put on the market after 1 March 2007.
1.7 CE compliance
FlexiPacket Hub 800 is in compliance with the essential requirements and other relevant
provisions of Directive: 2006/95/EC, 2004/108/EC, and 1999/5/EC.
Figure 2 CE marking
1.8 MEF compliance
FlexiPacket Hub 800 operating at the NNI delivers EPL, EVPL and E-LAN service
complies with the Metro Ethernet Forum MEF14 technical specification. FlexiPacket
Hub 800 operating at the UNI delivers EPL, EVPL and E-LAN service complies with the
Metro Ethernet Forum MEF9 technical specification.
The product is marked with the CE marking
8/10/2019 05 Idu Accessories Product Description
11/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
11
IDU Accessories Product Description Preface
Figure 3 MEF certified compliant logo
8/10/2019 05 Idu Accessories Product Description
12/40
12 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionOverview
2 OverviewThe main accessories of FPH800 includes the following.
gAll accessories must be ordered separately. They are not in the default delivery ofFPH800.
2.1 FPH800 plug-in cards
FPH800 supports plug-in cards for carrying traffic coming from the co-located equip-
ment.
2.2 FPH800 connection accessaries
FPH800 can be connected to local traffic through the following types of accessories.
Cables and connectors for Ethernet copper interfaces.
Cables for Ethernet optical interfaces.
Cables for STM-1 optical interfaces.
Cables for E1 interfaces.
Cables and connectors for FB interfaces.
SFP modules are designed to support ATM, SDH, SONET, GE and Fiber Channel com-
munication standards.
2.3 FPH800 patch panels
Patch panel is used if the local equipment does not support MDR68 connector in E1/T1
traffic transmit. Patch panel works as a switcher between FPH800 mainboard and the
local equipment, which switches the signals from MDR68 connector to RJ45 connec-
tors, CC4 connectors or BNC connectors.
2.4 FPH800 dual-IDU accessaries
To support dual-IDU mode for FPH800s, some dedicated accessories have been intro-
duced (e.g., shroud, protection panel and optical splitter modules).
2.5 FPH800 USB key
FPH800 is equipped with a USB key for the backup of IDU configuration. It provides a
socket to host a 1 Gigabit USB key type. And the USB key is used for IDU/ODU config-
uration and software load backup. The USB key is pre-formatted of FAT mode in factory.
In case of Dual-IDU protected configuration, only one USB key is used, located in the
Main IDU.
2.6 FPH800 installation tools
The installation tool includes: Mounting bracket, ETSI N3 rack, 19-inch rack and rack
screws, nuts, etc.
8/10/2019 05 Idu Accessories Product Description
13/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
13
IDU Accessories Product Description FPH800 plug-in cards
3 FPH800 plug-in cardsFPH800 supports plug-in cards for carrying traffic coming from the co-located equip-
ment. The external cards can be placed in slot 1 and slot 2 on the FPH800 mainboard.
16-port E1/T1 Multi-Service Card
4-port GE RJ-45 Card
4-port SFP Card
2-port Power Injector Card
2-port FlexBus card
2-port STM-1/4 MSC Card
3.1 16-port E1/T1 Multi-Service card
16-port E1/T1 Multi-Service card is the PIU (Plug-in Unit) of the FPH800.
Figure 4 16-port E1/T1 Multi-Service card
3.2 4-port GE RJ-45 card
4-port GE RJ-45 card is the PIU of the FPH800, it provides extended 4 GE interfaces
based on 1000Base-T standard. If the GE interface is used as ODU interface, extra 2-
port Power Injector cardis needed.
Parameter Description
Interface 16 channels of E1/T1 interfaces
Cable type 32 pair 75 ohm impedance coaxial cable;
or 32 pair 120 ohm impedance coaxial
cable
Connector MDR68
Table 4 16-port E1/T1 Multi-Service card cabling
8/10/2019 05 Idu Accessories Product Description
14/40
14 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 plug-in cards
Figure 5 4-port GE RJ-45 card
3.3 4-port GE SFP card
4-port GE SFP card is the PIU of the FPH800, it provides extended 4 GE optical inter-
faces.
Figure 6 4-port GE SFP card
3.4 2-port Power Injector card
2-port Power Injector card supports 2 GE interfaces power feeding (1000Base-T).
Parameter Description
Interface 4 10/100/1000BaseT electrical inter-
facesCable type CAT6 S/FTP
Connector Shielded RJ-45
Table 5 4-port GE RJ-45 cabling
Parameter Description
Cable type single/multi mode fiber duplex
Connector type LC-LC duplex
Table 6 4-port SFP card cabling
8/10/2019 05 Idu Accessories Product Description
15/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
15
IDU Accessories Product Description FPH800 plug-in cards
Figure 7 2-port Power Injector card
3.5 2-port FlexBus card
2-port FlexBus card supports local FlexBus interfaces.
Figure 8 2-port FlexBus card
Parameter Ethernet ODU
Interface 2
10/100/1000BaseTEthernet electrical
interfaces & 2 ODU
interfaces
-
Cable type CAT6 S/FTP Double shielded, four twisted pairs, Cat-
5e cable compliant (for outdoor condition).
Each pin manages at least 24 AWG wire
diameter.
Connector type Shielded RJ45 Shielded RJ45 (towarding the power
injector card); amphenol (towarding the
Flexi-Packet Multi Radio)
Table 7 2-port Power Injector card cabling
Parameter Description
Interface 2 FB optical interfaces
Table 8 2-port FlexBus Card cabling
8/10/2019 05 Idu Accessories Product Description
16/40
16 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 plug-in cards
3.6 2-port STM-1/4 MSC card
2-port STM-1/4 MSC card provides 2 X STM-1 or 2 X STM-4 interfaces. When the user
change the interface between STM-1 and STM-4, all services related to the interface
must be shut down.
The main functions of this card include MSP 1 + 1, EoS (Ethernet over GFP over SDH)
and Virtual concatenation (VC-4, VC-12).
Figure 9 2-port STM-1/4 MSC card
Cable type Coaxial cable, double shielded, or semi-
rigid
Connector FlexBus TNC
Parameter Description
Table 8 2-port FlexBus Card cabling (Cont.)
Parameter Description
Interface 2 STM-1 optical interfaces with SFP
module or 2 STM-4 optical interfaces
with SFP modules
Cable type Multi-mode fiber patch cord or single-
mode fiber patch cord
Connector type LC-LC
Table 9 2-port STM-1/4 MSC card cabling
8/10/2019 05 Idu Accessories Product Description
17/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
17
IDU Accessories Product Description FPH800 connection accessories
4 FPH800 connection accessoriesThis chapter provides an introduction and overview of the connectors and cables used
in FPH800 local connection. Most of the interfaces are located on the front panel. Only
the grounding point is on the lateral side of FPH800.
g For details on cables and connectors connecting ODU interfaces, refer to ODUmanuals.
Before the introduction of cables, SFP (small form-factor pluggable) modules is to be
introduced.
4.1 SFP transceiver
SFP interface
There are 2 SFP interfaces on the front panel of FPH800 which can be configured to
Ethrenet port or STM-1 port by software. SFP interface is designed to support SDH and
GE communication standards.
SFP transceiver
SFP transceiver, or SFP module, is a compact, hot-pluggable transceiver used for com-
munication applications. It is specified by a multi-source agreement (MSA). It interfaces
FPH800 mainboard to a fiber optic or copper networking cable.
SFP transceivers are available with a variety of types, allowing users to select the appro-
priate transceiver for each link to provide required electrical or optical reach over the
available cable types. This solution gives interface flexibility for FPH800.
g For all the types and order codes of SFP modules, refer toIDU and Accessories OrderCodes Reference.
4.1.1 SFP transceiver for electrical interfaces
Electrical SFP is compliant with 10BASE-T/100Base-TX/1000 Base-T interfaces. It does
not support synchronous Ethernet.
Figure 10 Electrical SFP module application
RJ45Connector
4PairsCable
Electrical SFP Module
8/10/2019 05 Idu Accessories Product Description
18/40
18 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 connection accessories
4.1.2 SFP transceiver for optical interfaces
Optical SFP is compliant with 1000 Base-X, synchronous Ethernet and STM-1 inter-
faces. Multi-mode fiber and single-mode fiber are supported through different types of
SFP optical transceivers.
Figure 11 Optical SFP module application
4.2 Cables and connectors for Ethernet copper interfaces
Figure 12 GE electrical interfaces
FE/GE electrical interfaces
The cables and connectors in this section are used to connect Ethernet copper inter-faces on the front panel, such as
4 X 10/100/1000 Base-T ports.
DCN port.
LC
Optical Patch-Cord
Optical SFP module
Item Description
Interface type 10/100/1000 Base-T
Duplex mode Half and full
Rate 10/100/1000 Mbit/s
Table 10 GE/FE electrical interfaces
RJ45 Shielded Connector
4 Pairs Shielded Cable
ElectricalSFP Module
8/10/2019 05 Idu Accessories Product Description
19/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
19
IDU Accessories Product Description FPH800 connection accessories
RJ45 connector
RJ45 is a registered jack standard for a modular connector using 8 conductors, which
specifies the physical male and female connectors as well as the pin assignments of the
wires in a cable. The physical dimensions of the connectors are specified in ANSI/TIA-
1096-A and ISO-8877 standards.
Cat6 cable
Category 6 cable, commonly referred to Cat6, is a cable standard for Gigabit Ethernet
and other network physical layers that is backward compatible with Cat5/5e and Cat3
cable standard. Compared with Cat5 and Cat5e, Cat6 features more stringent specifi-
cations for crosstalk and system noise. The cable standard provides performance of up
to 250 MHz and is suitable for 10BASE-T, 100BASE-TX (Fast Ethernet), 1000BASE-T/1000BASE-TX (Gigabit Ethernet) and 10GBASE-T (10-Gigabit Ethernet).
Table 11is the property of GE copper cable with length = 5m. And users can also make
Ethernet copper cords with cables and connectors with the given order codes in brakets
for other length.
MDI type auto sensing MDI/MDIX
Front panel reference 10/100/1000 Base-T, DCN
Connector type Shielded GE RJ45 eight-pin gold plated finishing
Cable 4 pairs STP cat6
Power Supply -48 Volt P + E functionality is supported in interfaces 3
and 4. A label (Pwr) indicates the presence of the ODU
power supply.
Property Description
Order code CS73199.05
Connector 1 RJ45 (T555ETRJ.08)
Connector 2 RJ45 (T555ETRJ.08)
Cable Ethernet STP Cat6 cable (T555ECR5.00)
Length 5 m
Table 11 Property of GE copper cable reel with length = 5 m
Connector 1 Pair Color Connector 2
1 pair A + white/orange 1
2 pair A - orange 2
Table 12 Wiring
Item Description
Table 10 GE/FE electrical interfaces (Cont.)
8/10/2019 05 Idu Accessories Product Description
20/40
20 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 connection accessories
4.3 Cables for Ethernet optical interfaces
Multimode/singlemode optical cables are used to connect FPH800 optical GE interfaceover SFP optical modules with local traffic. The application of optical fiber is seen in
Figure 11.
For description on SFP interface and SFP module, refer to Section SFP transceiver for
optical interfaces.
GE optical interface
Gigabit Ethernet (GE) has the speed to 1000 Mbit/s.
LC connector
LC (Lucent Connector) connector is the most common type of connector. It terminates
the end of an optical fiber, and enables quicker connection and disconnection than splic-
ing. The connectors mechanically couple and align the cores of fibers so that light can
pass.
MM optical fiber
Multi-mode (MM) optical fiber is a type of optical fiber mostly used for communication
over short distances. Typical MM links have data rates of 10 Mbit/s to 10 Gbit/s over link
lengths of up to 600 m (300 m for 10 Gbit/s).
g For all the types and order codes of MM fiber patch cords, refer toIDU and AccessoriesOrder Codes Reference.
3 pair B + white/green 3
4 pair C + blue 4
5 pair C - white/blue 5
6 pair B - green 6
7 pair D + white/brown 7
8 pair D - brown 8
Connector 1 Pair Color Connector 2
Table 12 Wiring (Cont.)
Property Description
Cable type break-out cable 2 X 2.0 mm LSZH
Connector LC-LC
Fiber type multi-mode 50/125 um
Fanout leg length 195 +/- 5 mm
Table 13 Properties for MM fiber patch cord
8/10/2019 05 Idu Accessories Product Description
21/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
21
IDU Accessories Product Description FPH800 connection accessories
SM optical fiber
Single-mode (SM) optical fiber is better at retaining the fidelity of each light pulse over
longer distances than MM fiber. SM fiber can have a higher bandwidth than MM fiber.
g For all the types and order codes of SM fiber patch cords, refer toIDU and AccessoriesOrder Codes Reference.
4.4 Cables for STM-1 optical interfaces
Single-mode optical cables are used to connect FPH800 optical STM-1 interface over
SFP optical modules with local traffic. The application of optical fiber is seen in Figure
11.
For description on SFP interface and SFP module, refer to Section SFP transceiver for
optical interfaces.
STM-1 interface
The STM-1 (Synchronous Transport Module level-1) is the SDH ITU-T fiber optic
network transmission standard. It has a rate of 155.52 Mbit/s.
g For all the types and order codes of SM fiber patch cords, refer toIDU and AccessoriesOrder Codes Reference.
Insertion loss maximum 0.50 dB @ 1300 nm
Operating temperature - 25 OC ~ + 70 OC
The insertion loss test acc. to IEC 61300-3-4
Property Description
Table 13 Properties for MM fiber patch cord (Cont.)
Property Description
Cable type break-out cable 2 X 2.0 mm, Riser
Connector LC-LC
Fiber type single-mode 9/125 um
Fanout leg length 300 -50/+ 10 mm
Insertion loss maximum 0.50 dB @ 1550 nm
Return loss minimum 46 dB @ 1550 nm
Operating temperature - 25 OC ~ + 70 OC
The insertion loss test acc. to IEC 61300-3-4
The return loss test acc. to IEC 61300-3-6
Table 14 Properties for SM fiber patch cord
8/10/2019 05 Idu Accessories Product Description
22/40
22 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 connection accessories
For properties of SM fiber patch cord, refer to SM optical fiber.
4.5 Cables for E1 interfaces
E1 interface
An E1 link operates over two separate sets of wires, usually twisted pair calbe. The line
data rate is 2.048 Mbit/s which is split into 32 timeslots each being allocated 8 bits in
turn.
The E1/T1 interfaces are used only as local interfaces. There are 16 X E1/T1 interfaces
with 75 ohm and 120 ohm impedance.
The following table descripes the pin definition of the E1/T1 interface.
Item Description
Interface Type E1/T1 short haul
Front panel reference 16 X E1/T1Interface rate E1/T1 Software selectable
Connector type MDR68 connector
Table 15 E1/T1 interfaces
Pin
number
Pin function Direction Pin
number
Pin function Direction
1 TXTIP1 output 35 RXTIP1 input
2 TXRING1 output 36 RXRING1 input
3 TXTIP2 output 37 RXTIP2 input
4 TXRING2 output 38 RXRING2 input
5 TXTIP3 output 39 RXTIP3 input
6 TXRING3 output 40 RXRING3 input
7 TXTIP4 output 41 RXTIP4 input
8 TXRING4 output 42 RXRING4 input
9 TXTIP5 output 43 RXTIP5 input
10 TXRING5 output 44 RXRING5 input
11 TXTIP6 output 45 RXTIP6 input
12 TXRING6 output 46 RXRING6 input
13 TXTIP7 output 47 RXTIP7 input
14 TXRING7 output 48 RXRING7 input
15 TXTIP8 output 49 RXTIP8 input
16 TXRING8 output 50 RXRING8 input
17 GND - 51 GND -
Table 16 Pinout
8/10/2019 05 Idu Accessories Product Description
23/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
23
IDU Accessories Product Description FPH800 connection accessories
Pin 17, 34, 51 and 68 are required to be connected to Ground. DC isolation is possible
as an external option by not connecting the cable shield to the connector shield. The
RING pin of transmit and receive need connect to GND through the external cable when
supporting the unbalanced 75 ohm coaxial cable.
Coaxial cable
Coaxial cable, or coax, has an inner conductor surrounded by a flexible, tubular insulat-
ing layer, surrounded by a tubular conducting shield.
Coaxial cable is used as a transmission line for radio frequency signals. One advantageof coax over other types of radio transmission line is that in an ideal coaxial cable the
electromagnetic field carrying the signal exists only in the space between the inner and
outer conductors. This allows coaxial cable runs to be installed next to metal objects
such as gutters without the power losses that occur in other types of transmission lines.
Coaxial cable also provides protection of the signal from external electromagnetic inter-
ference.
g For all the types and order codes of E1 cables, refer toIDU and Accessories OrderCodes Reference.
18 TXTIP9 output 52 RXTIP9 input
19 TXRING9 output 53 RXRING9 input
20 TXTIP10 output 54 RXTIP10 input
21 TXRING10 output 55 RXRING10 input
22 TXTIP11 output 56 RXTIP11 input
23 TXRING11 output 57 RXRING11 input
24 TXTIP12 output 58 RXTIP12 input
25 TXRING12 output 59 RXRING12 input
26 TXTIP13 output 60 RXTIP13 input
27 TXRING13 output 61 RXRING13 input
28 TXTIP14 output 62 RXTIP14 input
29 TXRING14 output 63 RXRING14 input
30 TXTIP15 output 64 RXTIP15 input
31 TXRING15 output 65 RXRING15 input
32 TXTIP16 output 66 RXTIP16 input
33 TXRING16 output 67 RXRING16 input
34 GND - 68 GND -
Pin
number
Pin function Direction Pin
number
Pin function Direction
Table 16 Pinout (Cont.)
8/10/2019 05 Idu Accessories Product Description
24/40
24 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 connection accessories
4.5.1 75 ohm coaxial cable
Figure 13 75 ohm Coaxial Cable with MDR68 connectors
Construction
Conductor: 30 AWG solid bare copper wire
Insulation: Foam PE, diameter = 1.1 mm
Inner braiding: 0.08 mm bare copper wire, Min. 95% coverage
Inner jacket: LSZH, gray, diameter = 1.8 mm, identified with number
Outer braiding: 0.10 mm bare copper wire, Min. 40% coverage
Outer jacket: LSZH, black, diameter = 14.0 mm
Braid construction: E1 patch cord 75 ohm MDR68-MDR68 cable assembly 60 exit, 32
core coaxial cable
Electrical characteristics
Conductor DC resistance: < 365 ohm/Km at 20C
Impedance: 75 5 ohm at 1 MHz
Return loss: 3.3 dB/100 m at 1 MHz to 10 MHz
Attenuation: 3.3 dB/100 m at 1 MHz; 9.5 dB/100 m at 10 MHz
Assembly rating
Voltage rating: 30 V AC
Current rating: 0.5 A/Pin
Temperature rating: -40C to + 85C
Pin 1Pin 34
Pin 68 Pin 35
75ohm Coaxial Cable
MDR Plug Connector
MDR68 Shell
Termination Cable
Cable Joint
Pin 1
Pin 1Pin 35Pin 68
Pin 34
Pin 34
Pin 68Pin 35
8/10/2019 05 Idu Accessories Product Description
25/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
25
IDU Accessories Product Description FPH800 connection accessories
Insulation resistance: 100 M
Withstanding Voltage: 300 V AC
4.5.2 120 ohm coaxial cable
Figure 14 32 pair 120 ohm cable with MDR68 connectors
Construction
Conductor: Diameter 0.40 mm solid bare copper wire
Insulation: Foam PE, diameter = 0.82 mm
Drain Wire: 0.40 mm solid copper wire
Cabling: PET tape
AL/PET tape: Diameter 0.40 mm tined copper drain wire
Braiding: 0.12 mm bare copper wire, Min. 85% coverage
Jacket: LSZH, black, Max. diameter = 12.0 mm
Braid construction: E1 patch cord 120 ohm MDR68-MDR68 cable assembly 60 exit, 32
twisted pair shielded round cable
Electrical characteristics
Characteristic impedance: 120 5 ohm at 1 MHz
Twisted pair: Max. -53.0 dB/100 m at 1 MHz
Attenuation: Max. 2.8 dB/100 m at 1 MHz
Assembly rating
Pin 1Pin 34
Pin 68 Pin 35
32pair Shielded RoundCable
MDR Metal Junction Shell
MDR Connector
Pin 68
Pin 68
Pin 35
Pin 34
Pin 34
Pin 35Pin 1
Pin 1
8/10/2019 05 Idu Accessories Product Description
26/40
26 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 connection accessories
Voltage rating: 30 V AC
Current rating: 0.5 A/Pin
Temperature rating: -40C ~+ 85C
Insulation resistance: 100 M
Withstanding Voltage: 300 V AC
4.6 Cables and connectors for FlexBus interfaces
Figure 15 FB cable applicationFB interface
The FlexBus (FB) interface is designed to support legacy product interface from Nokia.
The FB interface only operate in local interface mode. It only transfers data between two
indoor units.
TNC connector
The TNC (threaded Neill-Concelman) connector is a threaded version of the BNC con-
nector. The connector has a 50 ohm impedance (75 ohm is also available). It has better
performance than the BNC connector at microwave frequencies.
For description on coaxial cable, refer to Coaxial cable.
Users can assemble FB cable with the cable and connector with the order codes given
below. Note that the two TNC connectors are alternative.
Order code Item
T55256.02 FB cable reel, 500 m
T55255.07 IDU/ODU TNC connector, male
Table 17 FB cable and connector
FLEXBUS CABLE
T55256.02
FLEXBUS CABLE
T55256.02
TNC CONNECTOR (MALE)
T55255.07
TNC CONNECTOR (MALE ANGLE)
T55255.08
8/10/2019 05 Idu Accessories Product Description
27/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
27
IDU Accessories Product Description FPH800 connection accessories
The cable interface uses +5 V and +3.3 V power supply for operation. The consumption
of the cable interface alone is around 200 mA and 80 mA for +5 V and +3.3 V respec-
tively.
4.7 D.C Power interface
FPH800 provides protection of power supply interface. If one power supply failed,
FPH800 can switch to the other. A power cable is an assembly of two electrical conduc-
tors, held together with an overall sheath. This interface carries the -48 Volt DC power
supply.
Figure 16 Power supply interface
T55255.08 IDU/ODU TNC connector, male angle
Order code Item
Table 17 FB cable and connector (Cont.)
Phoenix 4-Pin Connector
2 X 1.5 mm cable
Plastic Hook
(Lower Enclosure)
Plastic Hook
(Upper Enclosure)
8/10/2019 05 Idu Accessories Product Description
28/40
28 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 connection accessories
g A 12 A fuse is used in power channel.
Construction
Conductor: Standard tinned copper wire
Construction: 30 / 0.25 mm
Insulation: HD-PE
Nominal thickness: 0.7 mm
Minimum thickness: 0.53 mm
Nominal diameter: 3.00 0.10 mm
Filler
Braiding: 0.12 mm tinned copper wire
Coverage: 85%
Jacket: LSZH
Color: Optional
Nominal thickness: 0.74 mm
Minimum thickness: 0.60 mm
Nominal diameter: 8.00 0.20 mm
Interface type Floating -48 Volt DC
Voltage range -40.5 VDC to -57.6 VDC
When operating without ODU power supply the
system shall be able to operate in the extended
voltage range -38.4 VDC to -57.6 VDC.
Reference Indoor Unit / Variant 1, with the following exceptions:
the input voltage is floating
Front panel reference PWR A and PWR B
Connector type Phoenix 4 Pin connector, 12A.
Fastening by screw required.
Connector shell 4-Pole straight strain snap
Antistatic plastic bag BAG ESD 80x120 pink, zip lock
Maximum current 10 A
Table 18 Power supply interfaces
Pin number Pin function
1 PWR A +
2 PWR B +
3 PWR B -
4 PWR A -
Table 19 Pinout
8/10/2019 05 Idu Accessories Product Description
29/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
29
IDU Accessories Product Description FPH800 connection accessories
Electrical characteristics
Conductor DC resistance: 15 /Km
Insulation resistance: 100 M/Km
Dielectric strength: AC 2000 V/ 1Min
Machenical characteristics
Working temperature: -40C ~ +80C
Color code
4.8 Grounding cable
The grounding cable is 10 AWG UL cable which meets ROHS requirement.
Figure 17 Grouding cable assembly
Construction
Conductor: 104/ 0.254 mm stranded tinned copper wire
Nom diameter: 3.43 mm
Insulation: PVC
Color: Yellow/Green
Nom thickness: 0.76 mm
Min thickness: 0.69 mm
Diameter: 5.07 0.08 mm
Electrical characteristics Conductor DC resistance at 20C: 3.90 /Km
Sparkal test: 10000 V
Voltage rating: 600 V
Flame characteristics
Fire resistance: VW-1 and FT1, pass
Core Color Core Color
1 Black 2 Red
Table 20 Color code of power cable
8/10/2019 05 Idu Accessories Product Description
30/40
30 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 patch panels
5 FPH800 patch panelsThere are three types of patch panels applicable to FPH800, which are RJ45 patch
panel, CC4 patch panel, and BNC patch panel. The patch panels are the switching
equipments allowing the incoming signals from 16XE1/T1 interface MDR68 connector
to be output from 16XRJ45 connector, 32XCC4 connector or 32XBNC connector. If the
users equipment connecting to the FPH800 16XE1/T1 interface does not have the inlet
for MDR68 connector, one patch panel can be used to switch the signals to fit the con-
nector which can be carried by the equipment.
5.1 RJ45 patch panel
RJ45 patch panel is used to switch the signals input from MDR68 connector to be output
from 16XRJ45 connectors.
Figure 18 RJ45 patch panel
5.2 CC4 patch panel
CC4 patch panel is used to switch the signals input from MDR68 connector to be output
from 32XCC4 connectors.
Parameter Description
Height 22 mm
Width 440.6 mm
Depth 69.976 mm
Operating temperature -5C ~ +55C
Table 21 RJ45 patch panel characteristics
Pin 1Pin 34
Pin 68 Pin 35Pin 1
8/10/2019 05 Idu Accessories Product Description
31/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
31
IDU Accessories Product Description FPH800 patch panels
Figure 19 CC4 patch panel
5.3 BNC patch panel
BNC patch panel is used to switch the signals input from MDR68 connector to be output
from 32XBNC connectors.
Figure 20 BNC patch panel
Parameter Description
Height 22 mm
Width 440.6 mm
Depth 81 mm
Operating temperature -5C ~ +55C
Table 22 CC4 patch panel characteristics
Pin 1Pin 34
Pin 68 Pin 35
Out In
Parameter Description
Height 44 mm
Width 440.6 mm
Depth 54.1 mm
Operating temperature -5C ~ +55C
Table 23 BNC patch panel characteristics
Pin 1Pin 34
Pin 68 Pin 35
Out
In
8/10/2019 05 Idu Accessories Product Description
32/40
32 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionFPH800 USB key
6 FPH800 USB key
6.1 Physical information
g For the detailed codes and descriptions, please refer to FlexiPacket Hub 800 IDU Rel.2.5 Order Codes Reference manual.
The USB key is used for IDU/ODU configuration and software load backup. 1 GigaByte
Serial Data Flash memory is suitable for in-system reprogramming using Serial Periph-
eral Interface (SPI).
The USB key interface is not a real external interface because it does not enable any
interconnection of digital network components but it gives the external access of the
USB key unit that is a proper component of the equipment.
The USB key interface deals with a Serial Peripheral Interface (SPI) system that
consists of one master device and one slave device. Exactly, in the USB key interface,
the master is defined as the processor of the system controller unit providing the SPI
clock and the slave selection command. While the slave works as any non-volatile
memory device suitable for in-system reprogramming.
Figure 21 USB key connection
Mechanical demension and interface
Parameter ESD-rated enclosure
Length with cap 66.1 mm (2.602 in) MaxWidth 16.60 0.20 mm (0.654 0.008 in)
Height 7.02 0.20 mm (0.276 0.008 in)
Interface type/Front
panel reference
USB
Table 24 Mechanical dimension and interface
USB key
8/10/2019 05 Idu Accessories Product Description
33/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
33
IDU Accessories Product Description FPH800 USB key
6.2 Key characteristics
It is possible to insert the USB key under the powered appliance. And the replacement
key must not produce any temporary interruption of service. The insertion into the equip-ment connector is detected through the presence line toward the system controller with
the ground level.
The 3.3 V power source must be supplied to the interface throughout a protection fuse
to ensure the integrity of SPI. But it is needed to be aware of the environmental hazards
such as accidental short circuits possible at the interface, connector pins that are touch-
able throughout the front panel cut-out when the USB key is not inserted.
If the system controller need to RESET, the working USB key must be terminated and
the IDLE status should be set. After RESET condition is cleared, all the operation will be
resumed back to normal.
Performance
The Industrial Grade UFD is USB 2.0 high-speed (480 Mb/sec) and USB 1.1 full-speed
(12 Mb/sec) compliant.
LED functionality
The Industrial Grade UFD with standard enclosure incorporates a LED activity indicator
that functions as described below:
LED flashing: Industrial Grade UFD is transmitting/receiving data or is identification
process.
Default LED colors: Blue.
Environmental specifications
Appliance Connector type Notes
Device connector 8 contacts Double socket
straight through hole 2mmgrid
The connector is part of
USB key unit
Card connector 8 contacts right angle pin
header through hole 2mm
grid
Equipment access
Table 25 USB key connectors
Parameter Value
Sustained read up to 30 MB/sec
Sustained write up to 20 MB/sec
Table 26 Read/Write performance
8/10/2019 05 Idu Accessories Product Description
34/40
8/10/2019 05 Idu Accessories Product Description
35/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
35
IDU Accessories Product Description Dual-IDU accessories
7 Dual-IDU accessories
7.1 Dual-IDU shroud
Figure 22 Dual-IDU shroud
Figure 23 Backplane of the shroud
FPH800 shroud is designed for dual-IDU site configuration. 2 IDUs can be plugged into
the shroud. 2 guide pins are added at the backplane of the shroud for easy plug and 2
guide holes are added on FPH800 rear side to match this backplane.
With the backplane of the shroud, 2 FPH800 can work in active/standby.
g For details on dual-IDU site configuration and FPH800 rear side interfaces, refer to IDUProduct description.
BACKPLANE GUIDE PIN
GND
Parameter Description
Height 2 U
Width 450 mm
Depth 256 mm
Table 28 Shroud characteristics
8/10/2019 05 Idu Accessories Product Description
36/40
36 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionDual-IDU accessories
7.2 Dual-IDU protection panel and optical splitter
7.2.1 Protection panel
Figure 24 A protection panel with 2 optic splitters
The protection panel is used for local traffic in dual-IDU mode. Its user interface is con-
nected with local equipment, while its 2 IDU interfaces connected with 2 IDUs respec-
tively. Only one of the IDUs is working in active mode. The other IDU is used for traffic
protection.
The application above applies to
8 pairs of GE electrical interface
2 pairs of GE optical interface
1 pair of 16 X E1/T1 interface
gFor details on dual-IDU site configuration, refer to IDU Product Description.
7.2.2 Optical splitter
Figure 25 Optic splitter
The optic splitter is a plug-in unit of the dual-IDU protection panel. It must be ordered
separately from the protection panel. One protection panel fits 2 optic splitters at most.
Pin 1Pin 34
Pin 68 Pin 35Pin 1
OPTIC SPLITTER
Parameter Description
Height 1 U
Width 440 mm without brackets
Depth 150 mm
Table 29 Protection panel characteristics
OPTICAL INTERFACE
8/10/2019 05 Idu Accessories Product Description
37/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
37
IDU Accessories Product Description Dual-IDU accessories
When no optic splitter is installed, a blank panel should be installed in the place of the
splitter.
There are 2 kinds of optic splitters with the same look. One is for multi-mode (MM) fiber
connection and the other is for single-mode (SM) fiber connection. Users can tell fromthe label on the faceplate of the splitter.
7.3 Dual-IDU power injector
Power injector a 1-U-height box, which is used to support dual-IDU protection while 1 +
0 ODU is connected to the IDU. It realizes two funtions: one is to inject power for GE
port to ODU, another is to do GE splitter as the command from IDU via control port on
dual-IDU power injector. With this GE splitter function, GE impedence can be match and
the cable to ODU can be longer. The target is to reach 50 m.
IDU alarm interface is connected with dual-IDU Power injector port to control which IDU
is connected with ODU. These IDUs work in active/standby mode. In normal condition,ODU is connected with Master IDU via Power injector. If Master IDU is down, the Slave
one will be active and send out command to dual-IDU Power injector to switch. Dual-IDU
Power injector implements the switch as this command. In this case, one IDU failure will
not result in traffic down to ODU.
The supported GE interface number can be 4 for each dual-IDU Power injector, and 8
GE ports if cascaded dual-IDU Power injector is used.
A grounding connector is on the lateral side of the Power injector. It must be connected
to the grounding point on the rack.
Figure 26 Power injector
g Two dual-IDU Power Injectors support cascading for extensive ODU connection. The forthe connection application, please refer toIDU Product Descriptionmanual. In the cas-
cading connection, the cascaded cable is not provided by NSN. Please follow the pin
defination in Table 30to make the cascaded cable with GE cable and RJ45 connectors.
RJ-45 for Cascade
RJ-45 for Alarm from Dual-IDU
GE Electrical with Dual-IDU GE Electrical with ODUs
RJ-45 for External Alarm Power Connector
Connector 1 Pair Color Connector 2
1 pair A + white/orange 1
2 pair A - orange 2
3 pair B + white/green 7
4 pair C + blue 4
5 pair C - white/blue 5
Table 30 Wiring
8/10/2019 05 Idu Accessories Product Description
38/40
38 A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
IDU Accessories Product DescriptionDual-IDU accessories
6 pair B - green 6
7 pair D + white/brown 3
8 pair D - brown 8
Connector 1 Pair Color Connector 2
Table 30 Wiring (Cont.)
8/10/2019 05 Idu Accessories Product Description
39/40
A25000-A0800-E028-01-76P1
Issue: 1 Issue date: May 2013
39
IDU Accessories Product Description FPH800 installation tools
8 FPH800 installation tools
g For the detailed codes, please refer to IDU and Accessories Order Codes Reference.For the detailed description, refer to IDU HW Install.
FPH800 mounting kits includes the following.
FPH800 dual-IDU shroud 21 mounting kit
Containing 21 mounting bracket for shroud, screws and nuts.
FPH800 mounting kit 21 rack
Containing Lshaped brackets for 21 rack, plastic bags, screws, washers, spring
washers and nuts.
FPH800 mounting kit 19 rack
Containing Lshaped brackets for 19 rack, plastic bags, screws, washers, spring
washers and nuts.
Power connector kit
Grounding kit
Containing grounding cable, plastic bags, screws, washers, spring washers and
nuts.
FlexiPacket IDU NEBS-compliant
Containing grounding cable dedicated for NEBS use. Its an alternative for the
grounding kit.
g For FOC installation information, refer to FOC manuals.
8/10/2019 05 Idu Accessories Product Description
40/40
IDU Accessories Product DescriptionGlossary
9 Glossary
10 BASET (10BaseT)
IEEE 802.3 media standard abbreviation for a 10 Mbps baseband Ethernet usingtwisted pair cabling
100 BASET (100BaseT)
IEEE standard for high speed 100 Mbps Ethernet.
1000 BASET (1000BaseT)
IEEE standard 802.3ab for Gigabit Ethernet over an unshielded twisted-pair wire.
Asynchronous Transfer Mode (ATM)
Transfer mode in which the information is organised into cells. It is asynchronous in the
sense that the recurrence of cells containing information from an individual user is not
necessarily periodic.
Element Management System (EMS)
Part of the network management system that provides the management functions for a
set of network elements.
PPS&ToD
PPS: pulse per second.
ToD: time of day.
Synchronous Digital Hierarchy (SDH)
Standardized multiplexing protocols that support multiple transports over optical fiber.
Synchronous Optical Network (SONET)
Transfer mode standardised by ANSI that is a variation of the SDH international stan-
dard, designed to run on optical fiber.
Time-division Multiplexing (TDM)
Multiplexing technique in which two or more lower bandwidth communications channels
are combined into a higher bandwidth channel by allocating frequency time slots in turn
to each of the lower bandwidth communications.
Universal Asynchronous Receiver/Transmitter (UART)
A piece of computer hardware that translates data between parallel and serial forms.
UARTs are now commonly included in microcontrollers.