14
1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots (Dose <= 70Gy) lie within 1.4 cm from the surface

1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

Embed Size (px)

Citation preview

Page 1: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

1

Dose Location Histogram (DLH)DLH gives an idea about the location of cold / hot spots within a structure relative to its surface.

Eg: 85cc of cold spots (Dose <= 70Gy) lie within 1.4 cm from the surface

Page 2: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

2

Plan Robustness Analysis

Page 3: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

3

Generating Consensus ContourGraph of Agreement volume v/s Confidence level for the three methods: Apparent, kappa-corrected and STAPLE. User can interactively select the confidence level by dragging the red line and consensus regions will be updated accordingly. This process would change the estimated volume to match desired confidence level.

Page 4: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

4

Mirror- Scope

Well registered regions would exhibit symmetry

Page 5: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

5

Mirror- Scope

Poor registered regions would exhibit asymmetry

Page 6: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

Gridded ‘mirror-scope’Base and deformed images overlaid on the top of each other

Gridded Mirror Scope for the base and the deformed images

Page 7: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

Fast 3D Gamma Metric Based on "A fast algorithm for gamma evaluation in 3D”, Wendling et al, Medical physics, 34 (5), p. 1647, 2007. Works with doses of unequal dimensions and having associated transformations. Computation time for regular doses is ~2 seconds.

1

0

Page 8: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

Image Registration via command line

[basePlanC, movPlanC] = register_scans(basePlanC, movPlanC, baseScanNum, movScanNum, algorithm)

Page 9: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

CERR Extractor – makes it easy to combine Dosimetric and Clinical data

Outcomes and Clinical data

Treatmement d

ata

Page 10: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

CERR Extractor

STEP 1: Choose directory containing Tx plansSTEP 2: Choose structures to modelSTEP 3: Manually correct unconventional namesSTEP 4: COHORT REVIEWSTEP 5: Choose Excel file containing outcomes / clinical dataSTEP 6: Export Tx, outcomes and clinical information to DREESSTEP 7: Model

Page 11: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

Cohort Viewer

Page 12: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

Dose CT Profile

Page 13: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

Min/Max/Mean Dose Projection

Page 14: 1 Dose Location Histogram (DLH) DLH gives an idea about the location of cold / hot spots within a structure relative to its surface. Eg: 85cc of cold spots

IMRTP

Example solver: runOptimExample.m