Precision Performance and Maximized DrainagePrecision Performance and Maximized Drainage
2
CONCEPTCONCEPT
• PDS tile installed on concrete base
• FieldTurf installed over the tile
• Water flows: Through Turf and PDS 2x2 Tile Onto base Into drains
3
THE COMPLETE SYSTEMTHE COMPLETE SYSTEM
Crushed StonePDS Tile
Concrete
FieldTurf
4
THE COMPLETE SYSTEM – In ActionTHE COMPLETE SYSTEM – In Action
Crushed StonePDS Tile
Concrete
FieldTurf
5
Roof Top Anchoring – Special CaseRoof Top Anchoring – Special Case
Crushed StonePDS Tile
Concrete
FieldTurf
Wall
Angle Iron
Adhesive
6
MAJOR BENEFITSMAJOR BENEFITS
• Precision Performance
• Maximized Drainage
• Installation Friendly
• Reduced Installation Time
• Minimized Base Cost
7
PRECISION PERFORMANCEPRECISION PERFORMANCE
• Surface Consistency
Uniform surface…anywhere
64 squares conform to surface
No “bridging”
8
PRECISION PERFORMANCEPRECISION PERFORMANCE
• Exceptional Load Bearing Capacity
Max load at yield is 164 psi 4.3 times greater than competition
Design safety factor of 2.7 Competitor is 0.62…not much safety
1,088 legs and roman arches Support and distribute stresses Delivers long term performance
9
PRECISION PERFORMANCE - FEAPRECISION PERFORMANCE - FEA
10
PRECISION PERFORMANCEPRECISION PERFORMANCE
• Thermal Expansion and Contraction
PDS Tile will install flat in “heat”
224 thermal “u” joints per 2x2 tile Bi-directional 0°-90°
“Slack” in “Smart Clip” Bi-directional Ensures easy assembly
11
PRECISION PERFORMANCEPRECISION PERFORMANCE
• Tri-Axial Design
0°/ 90°/±45° resists bending and twisting
Grid holes less than 9/16” wide Eliminates “dip” causing gaps by 77%
• Turf Grip
18 Small “bumps” per small square
Edges of Tri-axial design
Infill acts as ballast
Turf stays in place. Sure footed.
12
MAXIMIZED DRAINAGEMAXIMIZED DRAINAGE
• Maximized Volume Voids
• Unequalled Vertical Permeability
• Unparalleled Horizontal Transmissitivity
• Outstanding Support
13
MAXIMIZED DRAINAGEMAXIMIZED DRAINAGE
• Maximized Volume Voids
PDS tile has 84% volume voids It’s more about what’s not there
Typical competitive product has 35%
PDS tile guarantees drainage
14
MAXIMIZED DRAINAGEMAXIMIZED DRAINAGE
• Unequalled Vertical Permeability
PDS tile has 71% surface voids
Ensures water flow through turf/tile
PDS tile never holds back water
15
MAXIMIZED DRAINAGEMAXIMIZED DRAINAGE
• Unparalleled Horizontal Transmissitivity
Optimized number of legs Ensures horizontal flow
Optimized leg ht Maximizes below tile volume
Lab tested (ASTM) PDS tile drains 153 times better than
competitive product
All this…in a low profile ½” design
0.172
0.328
16
MAXIMIZED DRAINAGEMAXIMIZED DRAINAGE
• Outstanding Support
1,088 legs 1.93 legs/si 19% leg area/si No load concentration Better than a bed of nails!
Leg Beveling Smooth “edges”
Added radii to bottom of legs
18
INSTALLATION FRIENDLYINSTALLATION FRIENDLY
• Lightweight design 1.468 lbs for 3.92 sf of tile Easy to handle, speeds up install Easy to cut
• 8 “Smart Clips” Provide firm positive lock
• Beveled “teeth” in clip Allows for easy tile removal
• Small rotation in Smart Clips Installer can roll up the tile Temporarily place it aside if required
8 S
ma
rt Clip
s8
Sm
art C
lips
19
PDS TILE – Transition JointPDS TILE – Transition Joint
FTTK Logo Bottom Left
Install PDS Joint Align with Centre
Face this way
FTTK Logo Bottom Left
Face this way
PDS Joint (Green)
20
REDUCED INSTALLATION TIMEREDUCED INSTALLATION TIME
• Installed in 50% less time
• Increased installation capacity
• Use PDS…make $$
Natural Soil or Fill
Crushed Stone
Liner
21
MINIMIZED BASE COSTMINIMIZED BASE COST
• Save significantly on base cost Depending on location
• Use PDS…save $$ !!!
Natural Soil or Fill
Crushed Stone
Liner
22
PDS TILE - TECHNICAL SUMMARYPDS TILE - TECHNICAL SUMMARY
Feature Value BenefitWeight Lightweight @ 1.468 lbs for a tile Easier to handle. Truck = one field
Field Conformance 64 small squares Conforms locally to field
Tri-axial design 0°/90°/±45° supports Resist bending and twisting
Smart Clip Easy to clip. Addresses expansion. Installer friendly. Easy to reposition.
Surface Dimensions 23.76” x 23.76” Tile efficient. Less for a field.
Tile Ht Remains ½” Low profile.
Leg Ht 0.328” Maximizes horizontal drainage.Added radii to bottom of legs
Roman Arches Optimized design Supports and distributes stresses
Vertical Flow: Permeability Surface Voids 71% Maximizes vertical drainage.
Horizontal Flow: Transmissitivity Volume voids – 84% Maximized volume under tile
Maximizes horizontal drainage.
Compression 164 PSI “Right spec.” Safety design factor 2.7
Thermal Expansion Joints 224 bi-direction “u” joints per tileSmart Clip has bi-directional “slack”
Easy install.Tiles expand & contract
Turf Grip 18 friction bumps. Friction with ribs. Improved turf grip. Sure footed.
23
PDS TILE MANUFACTURINGPDS TILE MANUFACTURING
• Currently Less than 4 days = 80,000 sf
• By Nov 2007 Less than 2 days
• High Capacity
24
PDS Installations: 2” Stone, LinerPDS Installations: 2” Stone, Liner
• Approx. 500,000 sf installed 5 fields in total PDS is validated
• Over 1 MM sf by 2008 Q1
• Varied climates Hot, Cold, Wet
Stadium Location SF DateDimond HS Alaska 98,000 Aug, 2007Schopflin California 167,000 Sep, 2007Spruce Grove Alberta 223,600 Oct, 2007
488,600
25
PDS Installations: Concrete or AsphaltPDS Installations: Concrete or AsphaltStadium Location SF Date
Aloha Stadium Hawaii 129,760 Jul, 2003Westminster College Utah 109,660 Jul, 2006McMahon Stadium Alberta 107,100 May, 2006Maranatha High School California 104,960 Sep, 2005University of Wisconsin Wisconsin 91,120 Aug, 2003Montclair Sate New Jersey 88,320 Jun, 2006Clark-Plan Texas 85,760 Jun, 2006Oregon State University Oregon 84,480 Jun, 2005St. John's University New York 80,464 Sep, 2002Sams Stadium Texas 71,440 Aug, 2007McMurray Louisiana 61,000 Oct, 2007Creighton University Nebraska 33,280 Sep, 2006Sara Roosevelt New York 25,600 Aug, 2006Lifetime Fitness Florida 19,900 Feb, 2007Denver Broncos Colorado 17,420 Jul, 2003GM Renaissance Michigan 8,000 Jun, 2006
1,118,264
26
Precision Performance and Maximized DrainagePrecision Performance and Maximized Drainage