Page 1: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

1

StruxureWare™ Building Operation

2012.05.01 1.1 to 1.3

Page 2: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 2- Buildings – Roadmap V 3.0 July 2012

Released: Q4 2011

G

Technology Highlights• Easy to Connect

• TAC I/A Series – MNL Support• Easy to Migrate

• NETWORK 8000 – Phase 1 (of 2)• Easy to Access

• Web connectivity using WebStation• Easy access to Automation Server or

Enterprise Server• Includes support for graphics, trends,

alarms, reports and more• Easy to Engineer

• Spreadsheet: Mass create/Mass change• Certified BACnet Compliance

• Automation Server BTL B-BC listed w/ WSPCertWeb Access

StruxureWare Building Operation v1.1

Page 3: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

3Schneider Electric - Buildings Business – Company Confidential

WebStation

●Direct access to the Automation Server and Enterprise Server via a web browser

● Supported: Internet Explorer 8 (32-bit) & Firefox 3.6 (32-bit)● No additional software or local installation at browser

machine needed; Java pre-requisite

●Delegate responsibilities and perform everyday operations

● View graphics, trends, schedules, and reports● Change values (e.g. temperature setpoints)● Update schedules● Manage alarms● Manage users● View customized workspaces as configured for WorkStation

●Secure access● WebStation requires user name and password for log on

Page 4: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

4Schneider Electric - Buildings Business – Company Confidential

MNL controller support●Native support for MNL controllers using the AS-L Automation Server

● Wire, configure, and program the MNL controllers as a native part of the StruxureWare Building Operation system – not as third party devices

● New “greenfield” MNL controllers natively supported

●Requires use of WorkPlace Tech Editor software● Software included with WorkStation v1.1 installation● License included with Editor Pack (script and function block programming)● Pre-requisite: MS Visio 2003 or MS Visio 2007 SP2

●Existing MNL controller supported – i.e. integration to an existing site● Existing .VSD files can be imported into the Automation Server; no conversion service● .VSD file is hosted in the Automation Server; no need to remotely manage files per

project

●Minimum versions for compatibility:● Standard MNL controllers: v4.1● MNL-800: v2.0

Page 5: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

5Schneider Electric - Buildings Business – Company Confidential

BTL and WSPCert BACnet® certifications

●AS-B has successfully passed two independent BACnet testing centers’ requirements

●With v1.1, the Automation Server has been certified by:

● BACnet Testing Laboratories (BTL) as a BACnet Building Controller (B-BC)

● WSPCert

●StruxureWare Building Operation’s BACnet MS/TP (b3 controllers) are BTL certified as BACnet Advanced Application

Controllers (B-AAC)

Page 6: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

6Schneider Electric - Buildings Business – Company Confidential

NETWORK 8000 backward compatibility (Phase 1)

● Support for ASD (Application Specific Device) field bus directly under an Automation Server

● Global Control Module (GCM) controller database conversion service available

● Convert GCM database to .XML file for Automation Server import

● Receive report for estimate of what is convertible and price

● Approx 98% of content successfully convertible

● Minimum NETWORK 8000 GCM controller version required for database conversion: v4.2M

OD

BU

S

StruxureWare Building Operation

WorkStation

StruxureWare

Building Operation WebStation

Page 7: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 7- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL

Conversion candidates in Version 1.1

●NETWORK 8000 systems with ASD field bus under a GCM● Maximum 10 GCMs in the system● Site is willing to create new graphics● If LCM field bus is present, must wait for Phase 2 or replace LCM devices with

Automation Server I/O modules or MNL controllers● Global Control Satellite (GCS) bus will not be supported in either phase

●Replace GCS units with Automation Server I/O modules or MNL controllers

StruxureWare Building Operation v1.1 Scalability Guidelines:

Max # of ASD devices on the bus (per Automation Server) 128

Max # of Automation Servers(Sites using more than one Automation Server require an Enterprise Server) 10

Max # of Enterprise Servers 1

Max # of concurrent users(includes sum of WorkStation + WebStation users simultaneously) 2

Page 8: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 8- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL

System requirements

●NETWORK 8000 GCM controllers: Minimum v4.2

●StruxureWare Building Operation v1.1● Released: December 2011

●Microsoft OS & SQL versions:● Windows XP (32-bit)● Windows 7 (32-bit)● Windows Server 2008 (32-bit)● SQL Server 2008 - Express & Standard versions (32-bit)

●Required for Reports Server

Page 9: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

9Schneider Electric - Buildings Business – Company Confidential

Engineering efficiencies●Introduction of Spreadsheet

● Spreadsheet enables creating and editing of multiple objects in a tabular format at once

● Supports copy/paste of cells to and from Microsoft Excel directly to the Spreadsheet view

●Rapidly create LonWorks Network Variables (NVs) ● Simplifies binding to external devices to the local node for value logging or

monitoring● No need to manually create the corresponding variable on the local node,

naming it, choosing the correct type, and then binding it

● v1.1 supports configuration of:

o Values

o Alarms

o Trends

o Automation Server’s I/O modules &

points

Page 10: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

10Schneider Electric - Buildings Business – Company Confidential

StruxureWare Building Operation v1.2

G

Technology Highlights

• Scalable• Support for 32 Automation Servers

• Easy to Integrate• EcoStruxure using Ecostruxure Web Services

• Easy to Migrate• NETWORK 8000 – Phase 2 (of 2)

• Energy Efficient• Energy Report Pack

• IT Friendly• 64-bit Support• Encrypted communication by default

TARGET PRODUCT READINESS: Q2 2012

Page 11: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 11- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL

StruxureWare Building Operation v1.2Web Services – Two approaches supported

●Generic Consume● General web services implementation to “consume” data into StruxureWare● Ideal when integrating to third party systems● Two approaches:

●Binding tool, Script programming based

●Schneider Electric Corporate Web Services (CWS) - Serve & Consume● Support “serving” and/or “consuming” data from other Schneider Electric

products & systems● CWS offer web services functionality beyond what is capable via Generic

Consume approach● Functionality defined: Serve and Consume

●Browse●Data access read/write●Alarm access read and acknowledge●Trend access read only

Page 12: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 12- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL

Scalability guidelines in Version 1.2

StruxureWare Building Operation v1.1 components:

Recommended # of LCM devices on the bus (per Automation Server) 12

Max # of LCM devices on the bus (per Automation Server) 31

Max # of ASD devices on the bus (per Automation Server) 128

Max # of Automation Servers(Sites using more than one Automation Server require an Enterprise Server)

32

Max # of Enterprise Servers 1

Max # of concurrent users(includes sum of WorkStation + WebStation users simultaneously)

10

Company Confidential – Internal Use Only12

Page 13: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 13- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL

Phase 2: LCM support, SIGNAL conversion

●Phase 2: Available in StruxureWare Building Operation v1.2

● Adds support for LCM (Local Control Module) field bus directly under an Automation Server

● Similar procedures in Phase 2 (as Phase 1) for GCM database to Automation Server database conversion

● Use the same database conversion service

● Adds support for conversion of an LCM bus in the Automation Server

StruxureWare Building Operation

WorkStation

StruxureWare

Building Operation WebStation

Page 14: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 14- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL

G

Technology Highlights

• Easy to Migrate

• TAC I/NET (HVAC)

• Engineering Efficiency• Modbus multi-read• One Automation Server for LonWorks,

Modbus and BACnet combined

• Easy to Identify• StruxureWare Building Operation

TARGET PRODUCT READINESS: Q3 2012

StruxureWare Building Operation v1.3Previously designated as v1.2.1

Note: No change to deliverablesjust the version number to facilitatehaving more than one revision of thesoftware loaded on a machine.

Page 15: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 15- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL

●I/NET HVAC only

●Scalability guidelines

●I/NET sites using X527-NPRs and NPR 2000s● Includes X527 used only for NPR (routing Controller LAN to IP) and web access

Current TAC I/NET system:

Recommended max # of links per ES – e.g. X527-NPRs, NPR2000s 55

Recommended max # of I/NET points (internal/external) per ES 100,000

Recommended max # of I/NET LAN devices per link (X527-NPR or NPR2000)(Example: DCUs, PCUs, and MCIs)

32

Total Controller LAN I/NET devices per ES – e.g. DCUs, PCUs, MCIs 300

Add-on StruxureWare components (targeted for v1.2):

Max # of concurrent users(includes sum of WorkStation + WebStation users simultaneously)

10

Max # of Automation Servers added 32

StruxureWare Building Operation v1.3

Page 16: 1 StruxureWare™ Building Operation 2012.05.01 1.1 to 1.3

Schneider Electric 16- Buildings – Roadmap– August 2011 COMPANY CONFIDENTIAL

StruxureWare Building Operation v1.3

Xenta

527-NPR

StruxureWare

WorkStation

StruxureWare Reports Server

StruxureWare

WebStation

StruxureWare Enterprise

Server

StruxureWare

WebReports

I/NET

database

Native Support:

BACnet IP Modbus TCP INET

BACnet MSTP Modbus RTU NW8k

LON IP Modbus ASCII

LON FTT-10