Upload
colleen-marsh
View
270
Download
8
Tags:
Embed Size (px)
Citation preview
11
TDA100D
Contents
1 Target Customer2 Selling Points3 Improvement from current KX-TDA1004 System Configuration 5 Compatibility between TDA100D and TDA/TDE 6 New PCMC
1 Target Customer2 Selling Points3 Improvement from current KX-TDA1004 System Configuration 5 Compatibility between TDA100D and TDA/TDE 6 New PCMC
22
1. Target Customer
33
1. Target Customer1. Target Customer
Target : 16 - 120 SLTs
Digital PT for manager or operator
MP
RD
LC
4Built-in
4 Digital PT Ports
New 24/16 SLC cardfor 120 SLTs
Single Line Telephone for employees
MC
SL
C 2
4/1
6 C
ard
Even if SLTs are mainly used, a few Digital PTs are required for manager or operator.New TDA100D has built-in support for 4 DLC ports for these Digital PTs.
MC
SL
C 2
4/1
6 C
ard
MC
SL
C 2
4/1
6 C
ard
MC
SL
C 2
4/1
6 C
ard
MC
SL
C 2
4/1
6 C
ard
Solutions >>Small - Mid Size Office
44
1. Target Customer1. Target Customer
With System Wireless
Built-in4 Digital PT
Ports
Wireless system give you anytime, anywhere access.New TDA100D supports 4 DLC ports for these wireless systems without the need for options.
MP
RD
LC
4
Retail Stores Warehouses
Automotive Dealerships
FactoriesSchools
Large Residences
Solutions >>Warehouse, Car dealer, Factory...
55
1. Target Customer1. Target Customer
Target : 30 - 50 Rooms
Digital PT for front deskM
PR
DL
C4
System Wireless for staffBuilt-in
4 Digital PT Ports
KX-T7710 for each room
New TDA100D has built-in support for 4 DLC ports for DPTs and system wireless without the need for options. If you use CA Call Accounting (FOC), it is easy to make a call billing per room.
23
2C
Seria
l
CA Call Accounting for simple billing
MC
SL
C 2
4/1
6 C
ard
MC
SL
C 2
4/1
6 C
ard
MC
SL
C 2
4/1
6 C
ard
New 24/16 SLC cardfor 50 SLTs
EXT.(room)101 call detail
Solutions >>Small Hotel
66
2. Selling Points
77
2. Selling Points2. Selling Points
Built-in!
NewNew
No need for PSU type selection. Built-in New PSU enables future expansion.
Over-Capacity PSU for the Future Expansion.
BeforeBefore
For Future expansion
Built-in DLC4 can be used for DPITS programming without additional DLC.
DLC Card
SLT
ProgrammingDPITS
NONeed
For DPITS Programming
NONeed
CSIF CardDLC Card
For Wireless System
PSU-S
Provide reasonable wireless system with Built-in DLC and Entry DECT terminal.
NewNew
Entry DECT
【 Current TDA100 】
【 New TDA100D 】 Built-inPSU
DLC DLC4
PSU
Solutions >>Simple Installation
88
2. Selling Points2. Selling Points
New Analog CO Cards & New 24/16 port SLC Cards save slots and provide expanded capacity
Need 2 types of card(CSLC & MSLC)
Built-in both Caller ID Function and Message Waiting Lamp Control
New 24/16 port SLC Card
【 Current 】 【 New 】
Only need One card(MCSLC24/16)
Need one LCOT16+ 2 CID card
Built-in Caller ID Function
New Analog CO Card
【 Current 】 【 New 】
Only need two cards(CLCOT8 + CLCOT8E)
8-port expansiondaughter cardKX-TDA1186
8-port base analogue CO card
KX-TDA1180
Solutions >>Flexible Expansion
99
2. Selling Points2. Selling Points
8 - 64SLT 16 - 120SLT【 Current 】 【 New
】
Max SLT Capacity 24 96 120 128
MECCard
PSU-M
TDA100
PSU-S
TDA100 Range
Plus more 8-DPT or Wireless
64
TDA200 TDA200 RangePSU-M
TDA100
TDA100D RangeTargeting between 24 to 120 SLT
TES824 Range
from small to mid-sized office
16
(24SLT× 5 + Built-in PSU)
(16SLT x 4 + OPB + PSU-S)
PSU/DLC4Built-in
Solutions >>Wide Cover from Upper TES824 to TDA200 Range
1010
3. Improvements from Current KX-TDA100
1111
3. Improvements from Current KX-TDA1003. Improvements from Current KX-TDA100
More SLT Capacity
Built-in MoreFlexibility
1. System Capacity - 120 SLT port without MEC and Power Supply Unit replacement2. New 24/16 port SLC card with built-in Caller ID* and Message Waiting Lamp Control*3. New Analog CO card with built-in Caller ID 8 ports by default and additional 8 ports expandability in same slot by option for easy expandability. 4. New MPR card with built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F5. New Shelf with built-in Power Supply Unit 6. SMDR Call storage – 2500 calls * PBX software feature is the same as KX-TDA100/200 MPR version 5. * Message waiting specification is similar to current MSLC16. * Caller ID specification is similar to current CSLC16. * * Provide new PC Maintenance Console dedicated for TDA100D (separated from current UPCMC) * All kind of card will be able to install to Slot 7
New
PS
U (B
uilt-in
)
Free
slo
t
MP
R
1 2 3 4 5 6
USB
Serial I/F
Free
slo
tF
ree s
lot
Free
slo
tF
ree s
lot
DL
C4
PS
U-S
/M (O
ptio
n)
Free
slo
t
MP
R
1 2 3 4 5
USB
Serial I/F
Free
slo
tF
ree s
lot
Free
slo
tF
ree s
lot
Free
slo
t
6
Free
slo
t
< Current TDA100 >
< New TDA100D >7
Free
slo
t
Solutions >>Feature Differnce from Current KX-TDA100 V5*
1212
3. Improvements from Current KX-TDA1003. Improvements from Current KX-TDA100
Model TDA100 (reference) TDA100D
MEC w/o MEC(Max. No. of User is 64)
w/MEC RegardlessMEC
PSU PSU-S PSU-M PSU-S PSU-M New PSU (Built-in)
Extension System Total 64 96 160 176 (*)
MPR DPT(DXDP) 0 0 0 4 (8)
Free Slot
IP-PT 64 96 96 112
SLT 64 64 96 128
DPT(DXDP) 64 64 128 96(96)
Total 64 96 160 168
Trunk System Total 120 120 120 126 (**)
Free Slot
LCOT 96 96 96 112
BRI 96(48BRI) 96(48BRI) 96(48BRI) 112(56BRI)
PRI 120(4PRI) 120(4PRI) 120(4PRI) 120(4PRI)
IP-GW 64 64 64 64
(*) TDA100D: In case of PT configuration : Max. 176 extensions with 104 DPT(DXDP) + 48 IP-PT + 24SLT(**) Max. 126 trunks with one PRI30 + 96 LCOT. When installing T1, E1, PRI30, or PRI23 cards, make sure that the number of these cards X 2 + the number of other cards (including IP-GW4E cards) does not exceed 8.
Simpler installation to expand system capacity than the current TDA100.No additional MEC or PSU is required for Max. configuration (including 128 SLT or 152 DPT/IP-PT).- Memory Expansion Card is NOT required for more than 64 extensions.- No need to replace PSU for more than 64 extensions.
Solutions >>System Capacity
1313
3. Improvements from Current KX-TDA1003. Improvements from Current KX-TDA100
Slot TDA100 w/PSU-M TDA100D w/new PSU TDA100D w/new PSU
MPR - 4DPT I/F -
1 DHLC8 New MCSLC24/MCSLC16 New MCSLC24
2 SLC16 New MCSLC24/MCSLC16 New MCSLC24
3 SLC16 New MCSLC24/MCSLC16 New MCSLC24
4 SLC16 New MCSLC24/MCSLC16 New MCSLC24
5 SLC16 New MCSLC24/MCSLC16 New MCSLC16
6 (Trunk) (Trunk) New MCSLC16
7 - (OPB3) (Trunk)
SLT Total 72 120 128
Configuration Example
Specifications
- 24/16 SLT ports per card- Max. 5 MCSLC24/Max.7 MCLSC16 cards per PBX- 2 Power Failure Transfer (PFT) ports- Built-in Caller ID (FSK) & Message Waiting Lamp Control * Caller ID specification is similar to current CSLC16. * Message waiting Lamp specification is similar to current MSLC16. * No self diagnostic function by PCMC
Provide New 24/16 ports SLT interface card with built-in Caller ID and Message Waiting Lamp control.With this card, users can expand the number of SLT extensions up to 128. (Cannot use DLC4 on MPR cards.)
Solutions >>New SLC24/16 Card (MCSLC24/MCSLC16) with CID and MW lamp
1414
3. Improvements from Current KX-TDA1003. Improvements from Current KX-TDA100
Built-in
Caller ID circuit
Built-in
Caller ID Circuit
Provide New 8-port Analog CO line interface card with 8-port expansion board.New card will support CID functions as a standard. Accordingly, this card will provide flexible system expansion capability and low-cost installation for users that require CID.
8-port base LCOT card
2 PFT ports
8–port expansion daughter card
Mount to Base board
Specifications
- 8 analog trunk ports per card- Expand up to 16 ports with 8 ports daughter card- 2 power failure transfer (PFT) ports for 8 / 16 ports - Built-in Caller ID- Pay tone detection is not available- User-supplied Amphenol connector I/F
Solutions >>New 8-port Analog CO Card with 8-port expansion
1515
Solutions >>
3. Improvements from Current KX-TDA1003. Improvements from Current KX-TDA100
TDA100MPR
New TDA100D MPR
FRONT VIEW
RJ11For DLC 4 Ports
RJ45For MOH x2& Pager x2
RS-232C For SMDR
SCALE-UP
SIDE VIEW
Built-in DLC4 (4 DPT + 4 D-XDP) & Serial I/F for easy and cost effective installation.Users who mainly use SLT do not need to purchase DHLC cards at the initial installation. In addition, - Expand SRAM capacity for supporting SMDR data registration up to 2500 calls - I/F for two Music On Hold input ports and two External Pager output connectors will be changed to a RJ45.
- Serial Interface (RS-232C) port will be mounted on MPR cardNote: 1. System will not work correctly when a new MPR card is installed to an existing TDA/TDE shelf. But no safety issues will occur. 2. Exchange cable, from MOH/Pager mini jack to RJ45, will not be provided.
FRONT VIEW
New MPR Card for TDA100D
1616
3. Improvements from Current KX-TDA1003. Improvements from Current KX-TDA100
Type Maximum Load Figure
System Total (DPT, CS and SLC card) 128
DPT and CS 104
Type Load Figure
PT DPT (DT300, T7600) 1
IP-PT 0
SLT card New MCSLC24 24
New MCSLC16 16
CS 2-4ch CS 4
8ch CS 8
Calculate the load figure from the type of equipment to be connected.
A new shelf with built-in Power Supply Unit (PSU) is provided.New power supply supports up to 128 load figure including max.104 for DPT/CS (see below).Therefore, users do not need to replace PSU when expanding the system.In this respect, TDA100D will cover TDA200 user range.
Note: 1. Power supply and Shelf will be a new design, so there will be some incompatibility with the existing TDA/TDE series.
2. Current PSU-S/M (TDA0108/TDA0104) will not be used for TDA100D. 3. System will not work correctly when existing TDA/TDE MPR cards are installed in to a new TDA100D shelf. In this case, no safety issues will occur.
New PSU-S (Built-in) Add 7th
Slot
New Shelf and Power Supply
Solutions >>New Shelf and Power Supply Unit for TDA100D
1717
4. System Configuration
1818
4. System Configuration4. System Configuration
<Option>Max. Number of card/unit
TDA100 TDA200 TDA100D
Trunk Total 6 (*1) 8 (*1) 7 (*1)LCOT4LCOT8 6 8 7LCOT16CLCOT8 - - 7CLCOT8EDID8E&M8 6 8 7BRI4BRI8T1E1 4 4 4PRI30PRI23IP-GW4IP-GW4E 4 4 4IP-GW16
<Option> Max. Number of card/unitTDA100 TDA200 TDA100D
Ext Total 6 8 74DPT I/F on MPR - - 1DLC8DLC16 6 8 7IP-EXT16DHLC8SLC8SLC16 6 8 -CSLC16MSLC16 New MCSLC24 - - 5New MCSLC16 - - 7CSIF4 4 4 4CSIF8
CTI-LINK 1 1 1OPB3 4 4 4 MSG4 ESVM2 4 4 4 ESVM4 DPH4 4 4 4 DPH2 8 8 8 EIO4 4 4 4 ECHO16 2 2 2
(*1) One T1, E1, PRI30, PRI23, or IP-GW4 card counts as 2 cards.
CS CS(2-4ch) 32 32 26
CS(8ch) 16 16 13
Solutions >>Optional Card / Unit
1919
4. System Configuration4. System Configuration
TDA100 TDA200 TDA100D
PSU-S PSU-M PSU-M PSU-L New PSU
Extension System Total 64 96 128 128 128
MPR DPT(DXDP) 0 0 0 0 4 (8 w/DXDP) 0
Slot SLT 64 96 128 128 120 128
Analog CO
064
SLT
128
96
96 128
TDA200 w/ PSU-M
48
32
120
16
TDA100 w/ PSU-S
TDA100 w/ PSU-M & MEC
Expanded SLT capacity
<CO and SLT capacity chart >
112
Solutions >>SLT Max. Capacity Comparison
2020
5. Compatibility between TDA100D and TDA/TDE
2121
5. Compatibility between TDA100D and TDA/TDE5. Compatibility between TDA100D and TDA/TDE
Model Description TDE100/200MPR V3
TDA100/200
MPR V5
MPR Software - MPR Software of TDA100D No No
MPR Card - MPR card of TDA100D (w/ DLC4) No No
Trunk Cards KX-TDA1180 8-Port Analogue Trunk Card with CID (CLCOT8) No(in future)
No
KX-TDA1186 8-Port Analogue Trunk with Caller ID daughter Card(CLCOT8E)
No(in future)
No
Extension Cards KX-TDA1178 24-Port Single Line Telephone Card w/ Caller ID & MW Lamp control (MCSLC24)
No(in future)
No
KX-TDA1176 16-Port Single Line Telephone Card w/ Caller ID & MW Lamp control (MCSLC16)
No(in future)
No
Power Supply Unit
- New S-Type Power Supply Unit (new PSU-S) No No
Solutions >>New Cards for existing TDA/TDE system
2222
(*1): KX-TDA0920 will be updated before TDA100D released, (*2): Existing TDA/TDE MPR card will be able to install TDA100D KSU physically, but function will not work properly. (*3): DMPR support 2500 SMDR data registration, so that No MEC card support is needed
Model Description TDA100D
MPR Software - MPR Software of TDA100/200 No
Optional SD MemoryCards
KX-TDA0820 SD Memory Card for Software Upgrade No
KX-TDA0920 SD Memory Card for Software Upgrade to Enhanced Version Yes(*1)
MPR Card - MPR card of TDA100/200 or TDE100/200 No(*2)
MPR Option Card KX-TDA0105 Memory Expansion Card (MEC) No (*3)
KX-TDA0196 Remote Card (RMT) Yes
Trunk Cards KX-TDA0180 8-Port Analogue Trunk Card (LCOT8) Yes
KX-TDA0181 16-Port Analogue Trunk Card (LCOT16) Yes
KX-TDA0182 8-Port DID Card (DID8) Yes
KX-TDA0183 4-Port Analogue Trunk Card (LCOT4) Yes
KX-TDA0184 8-Port E & M Trunk Card (E&M8) Yes
KX-TDA0187 T-1 Trunk Card (T1) Yes
KX-TDA0188 E-1 Trunk Card (E1) Yes
KX-TDA0189 8-Port Caller ID/Pay Tone Card (CID/PAY8) Yes
KX-TDA0193 8-Port Caller ID Card (CID8) Yes
KX-TDA0284 4-Port BRI Card (BRI4) Yes
KX-TDA0288 8-Port BRI Card (BRI8) Yes
KX-TDA0290CE PRI Card (PRI30) Yes
KX-TDA0290 PRI Card (PRI23) Yes
KX-TDA0480 4-Channel VoIP Gateway Card (IP-GW4) Yes
KX-TDA0484 4-Channel VoIP Gateway Card (IP-GW4E) Yes
KX-TDA0490 16-Channel VoIP Gateway Card (IP-GW16) Yes
5. Compatibility between TDA100D and TDA/TDE5. Compatibility between TDA100D and TDA/TDE
Solutions >>Existing Card for TDA100D (1/3)
2323
Model Description TDA100DExtension Cards KX-TDA0143 4 Cell Station Interface Card (CSIF4) Yes
KX-TDA0144 8 Cell Station Interface Card (CSIF8) Yes
KX-TDA0170 8-Port Digital Hybrid Extension Card (DHLC8) No
KX-TDA0171 8-Port Digital Extension Card (DLC8) Yes(*1)
KX-TDA0172 16-Port Digital Extension Card (DLC16) Yes(*1)
KX-TDA0173 8-Port Single Line Telephone Extension Card (SLC8) No
KX-TDA0174 16-Port Single Line Telephone Extension Card (SLC16) No
KX-TDA0175 16-Port Single Line Telephone Card with MW Lamp (MCSLC16) NoKX-TDA0177 16-Port Single Line Telephone Card with Caller ID (CSLC16) No
KX-TDA0470 16-Channel VoIP Extension Card (IP-EXT16) Yes
Other Cards KX-TDA0161 4-Port Door phone Card (DPH4) Yes
KX-TDA0162 2-Port Door phone Card (German Type) (DPH2) Yes
KX-TDA0164 4-Port External Input/Output Card (EIO4) Yes
KX-TDA0166 16-Channel Echo Canceller Card (ECHO16) Yes
KX-TDA0168 Extension Caller ID Card (EXT-CID) No
KX-TDA0190 Optional 3-Slot Base Card (OPB3) Yes
KX-TDA0191 4-Channel Message Card (MSG4) Yes
KX-TDA0192 2-Channel Simplified Voice Message Card (ESVM2) Yes
KX-TDA0194 4-Channel Simplified Voice Message Card (ESVM4) Yes
KX- TDA0410 CTI Link Card (CTI-LINK) Yes
5. Compatibility between TDA100D and TDA/TDE5. Compatibility between TDA100D and TDA/TDE
Solutions >>Existing Card for TDA100D (2/3)
(*1): KX-TDA0171,0172 LPR Software will be updated before TDA100D released, so that when users use these existing cards for TDA100D, users must update to new software
2424
Model Description TDA100DPower Supply Units (PSUs)
KX-TDA0103 L-Type Power Supply Unit (PSU-L) NoKX-TDA0104 M-Type Power Supply Unit (PSU-M) NoKX-TDA0108 S-Type Power Supply Unit (PSU-S) No
Cell Stations (CSs)
2.4GHz KX-TDA0141 2-Channel CS Using a DHLC/DLC Card for 2.4 GHz PS NoKX-TDA0142 3-Channel CS Using a CSIF Card for 2.4GHz PS NoKX-TDA0151 2-Channel CS Using a DHLC/DLC Card for 2.4 GHz PS YesKX-TDA0152 3-Channel CS Using a CSIF Card for 2.4GHz PS Yes
DECT KX-TDA0141CE 2-Channel CS Using a DHLC/DLC Card for DECT PS NoKX-TDA0142CE 4-Channel CS Using a CSIF Card for DECT PS NoKX-TDA0155CE 2-Channel CS Using a DHLC/DLC Card for DECT PS YesKX-TDA0156CE 4-Channel CS Using a CSIF Card for DECT PS YesKX-TDA0158CE 8-Channel CS Using a DHLC/DLC Card for DECT PS Yes
DECT 6.0
KX-T0155 2-Channel CS Using a DHLC/DLC Card for DECT 6.0 PS YesKX-TDA0156 4-Channel CS Using a CSIF Card for DECT 6.0 PS YesKX-T0158 8-Channel CS Using a DHLC/DLC Card for DECT 6.0 PS Yes
Proprietary Equipment KX-A228 S/M-type Back-up Battery Cable YesKX-A229 L-type Back-up Battery Cable NoKX- A258 Blank Slot Cover YesKX-T30865 Door Phone YesKX-T7765 Door Phone Yes
5. Compatibility between TDA100D and TDA/TDE5. Compatibility between TDA100D and TDA/TDE
Solutions >>Existing Card for TDA100D (3/3)
2525
Model Description TDA100D
DPT DT300 DT346 6Line-LCD, with Backlight, 12CO, USB, Bluetooth optional Yes
Series DT343 3LIne-LCD, with Backlight, 12CO, USB, Bluetooth optional Yes
DT333 3Line-LCD, No Backlight Yes
DT321 1Line-LCD, 8CO Yes
DT390 DSS console Yes
T7600 T7636 6Line-LCD, with Backlight, 12CO, USB Optional Yes
Series T7633 3LIne-LCD, with Backlight, 12CO, USB Optional Yes
T7630 3Line-LCD, No Backlight Yes
T7668 1Line-LCD Yes
T7667 1Line-LCD, No Backlight, 12CO Yes
T7665 1Line-LCD, No Backlight Yes
T7625 No-LCD Yes
T7640 DSS console Yes
T7500 series No
T7400 series No
T7200 series No
5. Compatibility between TDA100D and TDA/TDE5. Compatibility between TDA100D and TDA/TDE
Solutions >>Terminal Compatibility for TDA100D (1/2)
2626
Model Description TDA100D
APT T7700 series No
T7300 series No
T7100 series No
T7000 series No
PT T7710 No-LCD, Message Lamp Yes
PS DECT TCA155,TCA256,TCA355, CA175 、 TCA275, etc. Yes
DECT6.0 TD7685,TD7695, TD7996 Yes
2.4G TD7684,TD7694, etc. Yes
Voice Mail TVM200 TDA100D supports two VM system (12port/24ch) Yes
TVM50 TDA100D supports two VM system (3port/6ch) Yes
Note: There will be some differences between TDA100D and existing TDA/TDE series as follow.1) SMDR and HOTEL information registration capacity will be increased up to 2500.2) Broadcasting (Announcement to 31 members) will be activated without MEC.
5. Compatibility between TDA100D and TDA/TDE5. Compatibility between TDA100D and TDA/TDE
Solutions >>Terminal Compatibility for TDA100D (2/2)
2727
6. New PCMC
2828
6. New PCMC6. New PCMC
Displayed only as the "TDA100D" icon in the "New" window.
"Multi-Site PBX Manager“ not supported
Solutions >>Dedicated PCMC for TDA100D
2929
End of Document