18
1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

Embed Size (px)

Citation preview

Page 1: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

1

Validation of EM Part of Geant4

Tsuneyoshi Kamae/Tsunefumi Mizuno

February 22, 2002 @ Geant4 Work Shop

Page 2: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

2

Purpose and Plan of this Talk

•Particle Ionization Energy Loss in Matters•Bethe-Bloch Formula (pp. 3-5)•Landau Distribution (pp. 3-5)•Range (p. 6)

•Processed related to electromagnetic shower•Pair creation (pp. 8-9)•Bremsstrahlung (p. 10)•Moller scattering/BhaBha scattering (pp. 11-12)•Comparison of shower profile with experimental data (pp. 13-14)•Comparison of shower profile with EGS4 (pp. 15-17)

We have validated EM processes in Geant4 important for gamma-ray satellite GLAST. Energy range of GLAST is 20 MeV - 300 GeV. So we need to validate physics processed down to ~10 MeV and lower.

•We use Geant4 2.0

Tracker (Si, Pb)

Calorimeter (CsI)

Page 3: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

3

Ionization Energy loss in matters•Shoot proton/electron in Pb and Si.•Cutoff Length: 0.4mm(e-), 0.1mm(others)

Thick absorber:Bethe-Bloch formula

Thin absorber:Landau distribution

Check mean energy loss (thick absorber), shape and most probable energy loss (thin absorber).

Page 4: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

4

Bethe-Bloch formula for protons

Geant4 well reproduces ionization energy loss in thick Si and Pb of proton down to 10 MeV

Page 5: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

5

Landau Distribution for protons and electrons

Fluctuation of energy loss and the most probable value in thin Si and Pb are appropriate.

protons electrons

Page 6: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

6

Range of protons

Shoot protons of 200 MeV and 1 GeV in CsI, Pb and W

Show good agreement within 0.6%.

Compare the results with NIST data: (http://physics.nist.gov/PhysRefData/Star/Text/contents.html)

Page 7: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

7

Processes related to EM shower•Pair creation (pp. 8-9) (and compton scattering and photo-electric effect)•Bremsstrahlung (p. 10)•Moller scattering (pp. 11-12)•Bhabha scattering (pp. 11-12)

We need to validate these processes, especially in low-energy, since•Pair creation and EM shower are key processes to determine gamma-ray energy and direction in the GLAST.•Low energy electrons may suffer large-angle scattering and cause trigger in the GLAST.

e-

Tracker(Si-Strip detectors)

Calorimeter(CsI scintillator)

•Cutoff 0.04mm(e-) 0.01mm(others)

Page 8: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

8

Pair creation – cross section

Geant4 correctly calculates cross section down to ~100 keV

Compare the cross section in Pb calculated by Geant4 with that of a reference (http://physics.nist.gov/PhysRefData/Xcom/Text)

Page 9: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

9

Pair creation-angular distribution of emitted

electrons

•We found discrepancies for low energy electrons and fixed the code

e- 4 MeV

0 0.125 0.25 0.50.375Theta [rad]

Eve

nts/

Bin

Eve

nts/

Bin

0 0.125 0.25 0.50.375Theta [rad]

e- 18 MeV

•Shoot 20 MeV gammas into Pb absorber (10% RL)•Compare the angular distribution of generated e- with that of theoretical formula

Page 10: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

10

Bremsstrahlung -- angular distribution of generated photons

Geant4 well reproduces the angular distribution of photons generated via bremsstrahlung down to ~1 MeV

•Shoot 20 MeV e- into Pb absorber (10% RL)•Compare the angular distribution of generated photons with that of theoretical formula

gamma 2 MeV

gamma 6 MeV

gamma 10 MeV

Page 11: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

11

Moller/Bhabha scattering(scattering with e-/e+)

•Shoot e- of 20 MeV and 100 MeV into Pb absorber (1% RL)•Compare the angular distribution of scattered electrons with that of theoretical formula

Page 12: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

12

Moller scattering (with e-)

G4 well reproduces the theoretical formula down to 20 MeV

100 MeV

Bhabha scattering (with e+)

20 MeV 20 MeV

100 MeV

Geant4

Theoretical furmula

Page 13: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

13

EM shower profile – Crannell experiment (1)

•Cranell experimtns:Carol Jo Crannell, et al., Phys. Rev. 184 (1969) 426

•Compare the G4 results with that of experimental data and EGS4 (Professor Nelthon and Liu).

•shoot 1GeV e- into water tank (10 rings and 11 layers)

Page 14: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

14

EM shower profile – Crannell experiment (2)

Shower profile of G4 is narrower than that of experiment and EGS4

longitudinal profile lateral profiles

Page 15: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

15

EM shower in Pb layers (1)To investigate the EM shower profile in the GLAST Tracker, we constructed 10 Pb layers(0.1RL each) with air (3cm). The radius is 0.2 Moliere radius (core of shower)

20 MeV, longitudinal profile

Geant4

EGS4

lateral profilesPb

air

Page 16: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

16

EM shower in Pb and air (2)

500 MeV, longitudinal profile

lateral profiles

5 GeV, longitudinal profile

lateral profiles

Geant4

EGS4

Geant4

EGS4

•Energy deposition is higher in Geant4 (low energy region)•Geant4 shows narrower shower profile (and could not be solved by fixing the angular distribution of pair creation)

Page 17: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

17

Effect of cutoff energy (length)

0.4mm, 0.04mm (e-), 0.1mm, 0.01mm(others)

•The discrepancy can not be attributed to cutoff length (energy)

Geant4

EGS4

The reason of the narrower shower profile is unrevealed.

Page 18: 1 Validation of EM Part of Geant4 Tsuneyoshi Kamae/Tsunefumi Mizuno February 22, 2002 @ Geant4 Work Shop

18

Summary

•We have validated EM part of Geant4 (2.0).•Energy loss in matters is well simulated down to ~10 MeV.•Angular distribution of pair-created e- was found to be inappropriate and fixed.•Cross section of pair creation, angular distribution of bremsstrahlung/Moller scattering/Bhabha scattering were validated down to ~10 MeV.•Shower profile of G4 is slightly narrower than that of experimental data and EGS4. The reason of this is unknown.