Upload
nguyendat
View
237
Download
4
Embed Size (px)
Citation preview
- 1 – Release 2.0
Service and Operating Manual
1000 W VHF FM amplifier
VL1000 PLUS
CTE INTERNATIONAL
VIA SEVARDI N°7
42010 ( ZONA IND. MANCASALE)
REGGIO EMILIA - ITALY
Edition 04/2001
This document may be duplicated or otherwise used or its contents made known to third parties only with permission of the originator or other authorized people.
Infringements constitute an offence and are subject to claim for damages. All rights reserved for patenting or utility model registration.
Printed in Italy Subject to change data without tolerances: typical values
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 2 – Release 2.0
Contents
1. Features 5 1.1 Uses.................................................................................................................................... 5 1.2 Main features ..................................................................................................................... 5 1.3 Locating main parts and connectors .............................................................................. 5
1.3.1 Front ........................................................................................................................................................ 5 1.3.2 Rear ......................................................................................................................................................... 6
1.4 Description of additional connectors ............................................................................. 6 1.4.1 Front panel.............................................................................................................................................. 6 1.4.2 Rear panel............................................................................................................................................... 7 1.4.3 DB15 PIN Description ............................................................................................................................ 7 1.4.4 Description of indicators....................................................................................................................... 8
2. Operation 9 2.1 Putting in operation .......................................................................................................... 9
2.1.1 Unpacking............................................................................................................................................... 9 2.1.2 Connections ........................................................................................................................................... 9
2.2 Switching the system on................................................................................................ 10 2.3 Cares and maintenance.................................................................................................. 10
3. Circuit Description 11 3.1 General ............................................................................................................................. 11 3.2 Power Splitter .................................................................................................................. 11 3.3 RF Amplifier..................................................................................................................... 11 3.4 Output Combiner............................................................................................................. 11 3.5 Low Pass Filter................................................................................................................ 11 3.6 Control Circuit ................................................................................................................. 12 3.7 Power Supply .................................................................................................................. 12
3.7.1 Main Filter ............................................................................................................................................. 12 3.7.2 Starting Point Limitation Circuit ......................................................................................................... 12 3.7.3 Power Supply Stage............................................................................................................................. 13 3.7.4 Auxiliary Voltage Supply (+15;-15)(+15-fans dedicated) .................................................................. 13
3.8 General Control ............................................................................................................... 13 3.8.1 Excessive SWR Protection.................................................................................................................. 14 3.8.2 Power Supply and Power Amplifier Overheating ............................................................................. 14 3.8.3 Supply Auxiliary Voltage -15V Failure ............................................................................................... 14 3.8.4 Measure................................................................................................................................................. 14 3.8.5 Display Failures.................................................................................................................................... 14 3.8.6 Warning Temperature .......................................................................................................................... 15 3.8.7 Function -3dB....................................................................................................................................... 15
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 3 – Release 2.0
4. Menu Commands 16 4.1 Start Up Condition .......................................................................................................... 16 4.2 Menu Description ............................................................................................................ 16 4.3 Navigation........................................................................................................................ 16
4.3.1 Navigation commands......................................................................................................................... 16 4.4 Flow chart ........................................................................................................................ 16 4.5 Upper line Menu (parameter selection)......................................................................... 18 4.6 Lower line Menu (seeing event log and settings)........................................................ 18
4.6.2 “Event Log” submenu ......................................................................................................................... 19 4.6.3 “Display” submenu.............................................................................................................................. 20 4.6.4 “Setting” submenu .............................................................................................................................. 20
5. Service 23 5.1 General information and warnings................................................................................ 23 5.2 Adjustments .................................................................................................................... 23
5.2.1 PCB S3110A .02 RF Power Amplifier Unit ........................................................................................ 23 5.2.2 PCB K3123A02 RF module control..................................................................................................... 23 5.2.3 PCB S3115D02– General controller ................................................................................................... 24 5.2.4 PCB K3113C.01 - Power Supply Unit ................................................................................................ 24
5.3 Opening the VHF amplifier ............................................................................................. 24 5.3.1 Removing the top cover ...................................................................................................................... 25 5.3.2 Removing the bottom cover................................................................................................................ 25 5.3.3 Dismounting fans................................................................................................................................. 25 5.3.4 Dismounting vent filter(s).................................................................................................................... 26 5.3.5 Replacing mains AC fuses.................................................................................................................. 26 5.3.6 Removing the AC Mains Filter Unit .................................................................................................... 26 5.3.7 Removing the Controller Unit ............................................................................................................. 26 5.3.8 Dismounting the front LCD Display Unit ........................................................................................... 26 5.3.9 Dismounting the AC Mains Power Switch......................................................................................... 26 5.3.10 Removing the RF Board Unit .............................................................................................................. 27 5.3.11 Removing the RF Filter Unit................................................................................................................ 27 5.3.12 Restoring the RF Board Unit............................................................................................................... 28 5.3.13 Removing the Power Supply board ................................................................................................... 28 5.3.14 Replacing the Lexan Keypad/LED Unit .............................................................................................. 28
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 4 – Release 2.0
Il lustrations
Mains part and connectors (front)....................................................................... 5 Mains part and connectors (rear) ....................................................................... 6 Additional connectors (front)............................................................................... 6 Additional connectors (rear) ............................................................................... 7 LED indicators .................................................................................................... 8 MENU FLOW CHART ...................................................................................... 17 Adjustments of PCB S3110A.02 RF Power Amplifier Unit ............................... 23 Adjustments of PCB K3123A02 RF module control ......................................... 24 Adjustments of PCB S3115D02 – General controller ....................................... 24 Adjustments of PCB K3113C.01 - Power Supply Unit...................................... 24 Front Panel....................................................................................................... 24 Rear Panel ....................................................................................................... 25
Annex
Circuit diagrams, parts lists and components Layout [AA1]
Attached file name
PCB Unit Reference Electric diagram
Component layout Part list
Input Power splitter AA
RF Amplifier module AB
Output Power Combiner
AC
RF Low pass filter AE
RF Control circuit AD
Power supply
Main AC supply filter
General control
LCD display unit
Keyboard
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 5 – Release 2.0
1. Features
1.1 Uses VL1000 PLUS is a modern 1000W FM amplifier which integrates the solid state reliability with the digital technology which makes it safe and easy to use.
High gain MOSFETs transistors and systematic use of state of the art manufacturing methods, have helped us to find effective solutions for the design this new equipment. The amplifier, of simple and rugged construction, is able to satisfy the requests of all those end-users looking for top-quality equipment at reasonable prices.
1.2 Main features - Weights only 32 Kg, for easy moving and maintenance. - Better operation temperature of the equipment, thanks to the air filter placed on the front panel and to
the optional air convey to be placed in the rear part of unit. - Impressive number of utilities, controls and data, with local or remote record facility. - Hi quality/price ratio.
1.3 Locating main parts and connectors Please make reference of the following pictures in order to locate the main parts of the VHF amplifier.
1.3.1 Front
Mains part and connectors (front) 1. AC Mains power switch. Allows to switch on/off the whole amplifier 2. Control panel - It’s composed by an alpha LCD display, 5 status LEDs as well as a keypad. The LCD
display normally shows the amplifier’s status and another parameter (e.g. power, time, date etc.). The combination between the keypad and the LCD makes easy to provide settings,check measurements etc.
3. Vent grid – from this grid the cooling air is taken in order to keep the proper working temperature. 4. Left front handles – use it in combination to the right handle to move the amplifier 5. Right front handles
2. 3.
5. 4.
1.
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 6 – Release 2.0
1.3.2 Rear
Mains part and connectors (rear) 1. RF input connector – connect to this input the output of the exciter (as per the following directions) 2. Right rear handle - use it in combination to the left handle to move the amplifier (it also fixes the rear
panel) 3. RF output connector – connect this output to the antenna (as per the following directions) 4. Fans – they provide the air flow necessary to the RF amplifier cooling 5. Ground terminal – general ground terminal 6. Left rear handle 7. AC power input plug – connect the AC mains supply voltage as per the following directions
1.4 Description of additional connectors A total of 8 connectors are available in the VHF amplifier. 2 of them are located in the front panel and the other 6 ones located in the rear panel.
1.4.1 Front panel
Additional connectors (front) 1. The RS232-type connector is an auxiliary RS232 front connection (to be activated via the menu as
described in paragraph 4.6.4 2. The connector marked with PROBE -60dB is a –60dB output coming from the RF Filter Unit suitable
for linear RF measurements in the 87,5 to 108 MHz frequency range
PROBE –60dB RS232
5.
7.
3.
2.
1. 6.
4.
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 7 – Release 2.0
1.4.2 Rear panel
Additional connectors (rear) 1. The twin (male and female) RS485-type connectors is designed for the eventual parallel connection of
more amplifiers 2. The RS232-type connector is designed for the connection to the exciter (if the exciter supports such
this connection). 3. The BNC connector is for the carrier enable 4. The 15 pin DB15-type connector is designed for several remote controls and services as described in
paragraph 1.4.3 5. AUX is a general purpose auxiliary switched AC output (2A max)
1.4.3 DB15 PIN Description
The wiring connections of the DB15-type connector is the following: 1. GND 2. Signal which is proportional to the power supply module output voltage (1V = 10V) 3. Signal which is proportional to the square root of the direct power (5V = 500W) 4. For factory use only 5. GND 6. STAND-BY command line (activated by short circuiting this line with GND) 7. Reserved 8. RESET command line (activated by short circuiting this line with GND) 9. Signal which is proportional to the power supply module output current (1V = 10A) 10. Signal which is proportional to the square root of the reflected power (4V = 50W) 11. For factory use only 12. STAND-BY signal (the contact is NC in normal operation, connected to GND in STAND-BY alarm) 13. NO alarm contact (the contact is NC in normal operation, connected to PIN 15 in ALARM mode) 14. NC alarm contact (the contact is NO in normal operation) 15. Common alarm contact (see 13 and 14)
2.
3. 1.
4.
5.
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 8 – Release 2.0
1.4.4 Description of indicators
Five indication LEDs are available in the front of the unit as per the following description and figure:
LED indicators - DCOUT – shows the availability of the power supply output voltage - ALC – when glowing, shows that the ALC (Automatic Level Control) is engaged, so the output RF
power can be kept constant - VSWR – glows when the VSWR is excessive - ALARM – indicates that an alarm has been occurred - POWER – indicates that the AC mains power is available
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 9 – Release 2.0
2. Operation
2.1 Putting in operation
2.1.1 Unpacking
After unpacking the VHF amplifier and choosing a suitable place to put it, check that all the necessary parts are available to continue: 1. VHF amplifier (already mounted in a standard 11 units rack, five of each are already occupied by the
VHF amplifier) 2. Spare fuses 3. AC power plug (inside its package) 4. Documentation
2.1.2 Connections
1. Make sure that the AC power switch I O is in O (Off) position 2. Connect all the earth wires coming from the other devices fitted in the rack to the earth terminal
provided in the rear of the equipment and marked with the appropriate symbol. 3. Connect the AC power cable to the provided AC power plug following the instructions printed on its
package, particularly taking care to the earth connection 4. Ensure that the AC mains supply voltage is 230VCA (±15%) and insert the AC power input plug in the
AC connector located in the rear of the VHF amplifier 5. Ensure that the antenna is suitable for the FM broadcasting frequency range (from 87.5 to 108 MHz)
with a continuous power capability of 500W and connect it to the 7/16-type RF Output connector
available in the rear of the VHF amplifier 6. Switch the exciter on and adjust it to the minimum output power
7. Connect the exciter’s RF output to the N-type RF input connector located in the rear panel. 8. Now the equipment is ready to work at the minimum configuration. For further connections, please
make reference on the connector description on paragraph 1.4
CAUTION: Maximum input power must not exceed 10W!
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 10 – Release 2.0
2.2 Switching the system on
1. Switch the VHF amplifier on by pressing the AC Power switch I O in I position 2. Switch the exciter on 3. Carefully and slowly raise the exciter’s output power and stop at the point in which the ALC LED
will steadily glow. 4. Now the system is operating. If all is properly working, the following LEDs should glow: DC OUT
(meaning that the power supply voltage is available) and POWER (AC mains power is available).
5. Moreover the upper line of the LCD display should show the output power and the lower should visualize Normal (normal working condition). The LCD Display should stay backlighted for 30 minutes after the last button pressed.
6. Check the forward and reflected RF power according to the instructions stated in paragraph 4.4
2.3 Cares and maintenance[AA2] As many other electronic equipment, this amplifier need some cares which are mandatory to guarantee years of perfect operation. On the other side, if maintenance operation won’t be regularly made, faults can occur, particularly in hard environments.
Air cooling fans must be regularly inspected and replaced every 10,000 hours according to the instructions stated at 5.3.3
Vent air filter must be regularly replaced or cleaned according to the environment conditions. To replace the filter, please follow the paragraph 5.3.4
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 11 – Release 2.0
3. Circuit Description
3.1 General
3.2 Power Splitter The input power from the exciter is applied to a 2 WAYS splitter 3 Db 90°; the signals on the outputs are out of phase by 90°.
The resistive termination resistor R1 absorb the unbalanced power when one of the BLF278 stages fail.
3.3 RF Amplifier The amplifier circuit is composed two identical base modules. The input matching of the active device BLF278 composed of two FET is done by means of the transformation ratio 4:1 of transformer T1, by the capacitor C1, C2 and by the inductor L1.
The resistors R1 and R2 connected between the two gates of BL278 serve to increase the margin of stability of the amplifier and at the same time to get a SWR that is acceptable over the whole operating frequency band.
The two FET composing the BLF278 operate in push pull mode.
The line connected between the two drains serves to compensate for the capacitate component of the output impedance. The ensuing impedance is raised by the transformation ratio 1:4 of the transformer T2, and so taken to the value of 50Ω by the adapter circuit composed of C7, L2 and L3.
The parallel resonating circuit composed of C6 and L2 is calculated so as to lower the value of the 2nd harmonic component generated by the amplifier.
The gates of the two FET are connected, by means R8, R41 and L6, to a polarization circuit(BIAS=2,3v). The direct voltage on the gates regulated by means the trimmer RV1.
The NTC physically located on the case of the active device serves to compensate the variation of the polarization on the basis of the operating temperature. Through point 9 connected to the control circuit is possible, by means of an appropriate negative voltage, to zero the level of output power in the event of operating trouble detected by the RF Control Circuit itself
The toroid ferrite cores the output transformer is wound on may be damaged by strong magnetic fields created by current.
This situation may arise in the event of a FET failure.
3.4 Output Combiner The power coming from the two BL278 stages are sent to the input of one 3dB couplers .
In output line is placed a directional coupler that detects the reflected power. The resistive termination R3 absorb all unbalanced power. At the ends of the termination there is a unbalanced detector. Both signal are connected the control circuit.
3.5 Low Pass Filter The output signal coming from the power amplifier module is connected to the input of a low pass filter.
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 12 – Release 2.0
This filter is a constant coupling type and it is composed by two π network section including two second harmonic traps.
The filter's capacitors consist in microstrips printed on a Teflon substrate. The inductances are made in silver-laminated copper wire wound in air.
The directional coupler is obtained with microstrips technology; it offers two voltages depending by the forward and reflected power. In this module is placed a probe RF –60db connected by a coaxial cable to the fron panel.
3.6 Control Circuit The protection function of the four BLF278 stages is obtained by the Control Circuit.
The amplifier is protected of the excessive SWR, excessive unbalanced powers and overheating. The signal WR coming from the "reflected power detector" of the RF module, it's amplified by U2A and will reach the comparator U2D.
If the reflected power will excess the pre-set value, set by the resistive trimmer RV1, the comparator U2D its output representing an excessive reflected power level.
The signal of unbalanced UMB2 previously processed, is offered to the diode D12 to the input of buffer U2B.
The output of U1B is connected to the comparator U2C which output represents excessive internal unbalanced power error. The intervention protection level of UMB2 can be adjusting with the resistive trimmers RV3.
When the temperature level of the heatsink reaches the intervention level (80°C), the temperature chip sensor at the center of the same heatsink transmits a signal to the microprocessor that switch of the Amplifier.
The constant current generator formed by transistor Q3 and surrounding, components, is feeding the diodes D4 and DZ1 and between their terminals always offers a voltage of 10V.
This is the polarization and the control voltage of the basic module.
The previous described are lead through D7 coming into the basis of the Darlington pair Q1 and Q2, in case of intervention, can regulate the control voltage to al level of about -12V which totally cutoff the output power of the module. If the control voltage (-15V auxiliary supply) fail the general control by means the microprocessor switch off the amplifier.
3.7 Power Supply The Power Supply is composed by four principal stages:
3.7.1 Main Filter
It consists in a board which is separate from the Power Supply and located in the internal side of the rear panel, The main filter has the purpose to limit the emission creates by the switching Power Supply and rejected to the main cable and it protects the equipment from overvoltages and noise coming from the main line.
3.7.2 Starting Point Limitation Circuit
A starting point limitation circuit provide to limit the spike current when the equipment is switched on. At the beginning of this stage there is the general protection fuse F1, which protects all the power supply board. The resistor which limits the initial current is R103, this resistor is further short circuited by the relay RL1
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 13 – Release 2.0
for the normal operation; the short circuit becomes operating in less than 1 second (the time necessary to charge the capacitors); this time is defined by an RC circuit.
3.7.3 Power Supply Stage
The Power supply stage is a switching type double conversion mains direct. The first stage conversion is AC/DC, it transform the 230V alternate signal into a 400V direct signal. The switching frequency is 40KHz. The circuit which provides the first conversion regulates the power coefficient of the 230V main line current absorption, the power coefficient at full charge isn’t less than 99%. The power factor control (PFC) is obtained by the dedicated IC UC3854 (U5) and related circuitry: P1 e P2, the IGBT transistor Q4, the inductor L1, diodes from D1 to D4 and capacitors from C8 to C11. This configuration offers a very effective protection against input overvoltages which are absorbed by the inductor L1 as well as the capacitors from C8 to C11, additionally increasing the reliability of the mains direct switching regulator.
The second conversion stage has a DC/DC half-bridge structure, it transforms the direct voltage from 400V to 48V insulated from the mains line. The switching frequency is 40KHz. The Power Supply is protected of an over charge, short-circuit of the output voltage and by means the General Control it is protected of the overheating.
The IC which provides the regulation of the half bridge stage is U4 SG3525. The half bridge is obtained by means of the IGBT transistors Q1 and Q7, by the capacitors C1 and C12, as well as the transformer T3 which offers galvanic insulation from the mains supply. The rectifying diodes are D9, D10, D17 and D22. The first filter cell is made by the inductors L4 and L7 as well as the capacitors C15 and C17, while the second filter cell is obtained with L5 and C19.
The second DC/DC conversion stage is intrinsically protected against overloads and short circuits and provides a variety of signals to the General Control board, e.g. the output current (obtained by the shunts from SH1 to SH4), the output voltage (obtained by the output), a signal which is proportional to the operating temperature (IC LM335 RK1 which is fixed to one heatsink nearby the diode D38). The second DC/DC conversion stage also receives the ALC feedback signal coming from the control board by means of L9 and R57 to the IC U2 changing the power supply voltage in order to keep constant the RF output power.
In case of overheating, the board acts on the opto-insulator U6 with a ST-BY hi level signal which locks the two stages U5 e U4 (SG3525) and highlights unwanted events. Therefore, any signal which is not referred to the ground or the accidental removal of the EC2 connector forces the power supply in stand-by mode.
The output voltage 100 Hz ripple is less than 20 mVPP at full load in order to minimize the residual AM modulation.
The total efficiency of the two conversion stages is 0.88.
3.7.4 Auxiliary Voltage Supply (+15;-15)(+15-fans dedicated)
A voltage supply main direct with three-output voltage + 15 and –15, additional +15 for the fans composes this circuit. The +15 and -15 voltages are necessary to feed all the chip of the equipment and the additional +15 is dedicated for the fans. On the output of the fans supply are plaecd two fuse to save the fans against short circuitThe circuit is protected of an over charge, short-circuit of the output voltage.
At the beginning of this stage the fuse F4 protects the whole auxiliary stage. The stage is obtained by a flyback-type stage made by the MosFET Q11, the transformer T4, diodes D16 and D18 as well as capacitors C78, C96 and C79. The regulation IC is UC3844 (U7). The transformer T4 offers a galvanic insulation between the generated auxiliary voltages and the source (the output coming from the bridge).
3.8 General Control The General Control Board is obtained with a microprocessor PIC17C756A with following characteristics: - Clock 16MHz - 12 input A/D 10bit
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 14 – Release 2.0
- 2 Universal asynchronous receiver transmit - The microprocessor is connected at the memory EEPROM 93C86 that has an 1K word capacity, at
the data/time chip, at an interface for two COM port RS232 and an interface for one COM port RS485
The microprocessor control all the protection of the power amplifier: - Excessive SWR - Power Supply Overheating - Power Amplifier Overheating - Supply Auxiliary Voltage-15V Failure - Unbalanced Power
Moreover it manage the navigation on the display of the functions: - Measure - Display Failures - Language - Reset Mode - Warning Temperature - Power Output -3 dB - Failure Counter - Time and Data Set
3.8.1 Excessive SWR Protection
The amplifier has two protections by the SWR. The first detector is located in the power amplifier module and the second is located in the Low Pass Filter. The first protection has an intervention time more quickly than the second.
In case of not correct antenna's impedance the General Control gives a signal at the power supply, it reduce the output voltage and so the RF output power will be reduced to have the maximum level of the SWR 1.8.
If there is a momentary spike of the reflected wave ratio (SWR) the detector on the power amplifier module gives a signal at the control circuit (located in same module) and it reduce the voltage of the BLF278's gate.
3.8.2 Power Supply and Power Amplifier Overheating
When the heatsink temperature of the power amplifier module and power supply module reaches about 80°C, the general Control switches the Power Supply off. In this case the equipment is in Stand by mode. During this process the fans will work, when the temperature will reach less than 70°C (approx.) the general control restores the normal Power Supply operation.
3.8.3 Supply Auxiliary Voltage -15V Failure
This supply voltage is important to control the voltage on the BLF278's gate. If it shall be broken The equipment will go in stand-by.
3.8.4 Measure
The measurement available via the menu (see 4.4 )are forward a direct power, voltage and current of the Power Amplifier, temperature regarding heatsink power supply and power amplifier; date and time.
3.8.5 Display Failures
The failures display indicates the alarm type that the equipment has (SWR, etc).
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 15 – Release 2.0
3.8.6 Warning Temperature
If this option is ON, when the heatsink temperature of the power amplifier module and power supply module reaches about 70°C (near to the level of overheating alarm) the General Control adjusts the equipment in order to output the half of the rated full power only (-3 dB/250W).
3.8.7 Function -3dB
This function allows to set the equipment's output power at -3 dB (the half of the rated full power).
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 16 – Release 2.0
4. Menu Commands
4.1 Start Up Condition At the start up the name, the version and the serial number of the equipment appear on the LCD display. Simultaneously all the LEDs will be tested.
At the end of the start up, the Main Menu will be visualized. It is composed by two lines: - The upper line shows the default measurement Dir. Pow. Which is the RF Output Power and is
followed by its value. This measurement can be changed by the menu according to your need. - The second line is the status of the equipment (Normal if all is going well).
4.2 Menu Description By entering the menu, it’s possible to change the default measurement displayed in the upper line of the LCD and to access to a range of visualizations (e.g. the event log) and settings (half output power, switching between front and rear RS232 connectors etc.)
4.3 Navigation
4.3.1 Navigation commands
- At the right of the LCD display there is an asterisk which indicates the selected menu item.
- The two keys and allow, respectively, to scroll the menu up and down in order to select the various menu items.
Note: the menu scroll function is not cyclic. Therefore after selecting the last menu item it’s
necessary to press the key in order to scroll the items back. - To access a menu item in order to change/set it, move the position of the asterisk on that item by
pressing the and keys and then press the key.
- By pressing at the same time the two keys and , the Main Menu is recalled and the selected menu item won’t be changed.
4.4 Flow chart The flow chart of the menu is organized as follows.
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 17 – Release 2.0
MENU FLOW CHART
OFF
ITALIANO
MEASURE
EXIT
AT POWER ONNEVER
EVERY 24H
EXIT
EXIT
ON
OFFEXIT
ADDRESS
STATUS EVENT LOG
SETTING
EXIT
DISPLAY EVENTSchrono order
LANGUAGE
RESET MODEof alarm counter
WARNING
-3 DB
FAILURE COUNTER
TIME SET
DATE SET
RS232 SWITCH
ALARM MEMORYRESET
EXIT
ENGLISH
ON
16EXIT
8
SET CLOCK TIME
SET CLOCK DATE
REAREXIT
VL1000 DISPLAY OP. (v.1.08)UP & DOWN ARROWS KEYS TO MOVE CURSORENTER KEY TO SELECT
FRONT
REF. POW.PA. VOLT.
DIR. POW.
EXIT
PA. CURR.RF. TEMP.PS. TEMP.
TIMEDATE
SET ADDRESS___.___
ENTER PASSW
-3dB____ 232____W___ C__ R__ Lc
DISPLAY SETTINGS
DISPLAY SETTINGS
REMOTEEXIT
LOCAL
SETTING MODE
-> to 'setting'
-> to 'main menu'
-> local=to 'setting' , remote=to 'mainmenu'
local
remote
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 18 – Release 2.0
4.5 Upper line Menu (parameter selection) As over stated, the upper line normally shows the RF Output Power. To show another parameter:
1. Make sure that the asterisk is on the upper line (or move it with the and keys)
2. Press the key in order to access the parameter list.
3. With the and keys, scroll the available parameters as per the following table:
Parameter Description
Dir. Pow. RF output power (in W)
Ref. Pow. Reflected power (in W)
PA.Volt. RF power amplifier supply voltage (in V)
PA.Curr. RF power amplifier drained current (in A)
RF.Temp RF power amplifier temperature (in °C)
PS.Temp Power Supply temperature (in °C)
Time Current time (hours, minutes and seconds)
Date Current date (in MM/DD/YY format)
Exit It’s obviously not a parameter, but a command to exit the menu without changing the current parameter.
4. Press the and keys in order to move the asterisk to the line which shows the new parameter to be selected (or to Exit in case you want to keep the current parameter).
5. Press the key in order to select the new needed measurement (or escape the list in case you selected Exit)
4.6 Lower line Menu (seeing event log and settings) As over stated, the lower line shows the amplifier status and can’t be changed, however this selects a Menu which allows to read the Event log as well as to read/change some settings. To access to this menu:
1. Make sure that the asterisk is on the lower line (or move it with the and keys)
2. Press the key to access the menu.
3. With the and keys, you can select three submenus:
Submenu Description
Event Log Allows to see the event log
Display Allow to see in one screen shot all the settings described at 4.6.3
Setting Allow to change each of the various available settings (access protected by a 3igits password)
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 19 – Release 2.0
Local/Remote Setting of the operational mode
Exit It’s obviously not a submenu, but a command to come back to the main menu.
4. Press the key in order to select the new needed submenu (or escape the submenus in case you selected Exit)
4.6.2 “Event Log” submenu 1. After entering in this submenu you will see the last event as per the following example
Display Description
First line Normal 67 Event name followed by its order number
Second line 12:56 09/06/00 Time and date in which the event happened
2. The and keys you can scroll the various events. The key moves to the lower order
numbers, while the key moves to the higher ones. The following list states the various events you could see and their description
Event Description
Normal Normal working condition
Vaux Fail Auxiliary supply voltage failure
PA Overheat RF power amplifier temperature was too high
PA Unbalance The four stages of the RF power amplifier were unbalanced
PS Overheat Power supply temperature was too high
PS Overload The current required to the power supply was too high
Exc.SWR Reflected power (SWR) was too high
Power-On Start up condition
Stand-By Al Automatic stand-by caused by an alarm
Stand-By Rem Manual stand-by was performed
-3dB Warning ON The amplifier automatically reduced its RF output power down to the half (-3dB) because the temperature was too high
-3dB Cmd ON -3dbB manual command was enabled
-3dB Off -3dbB manual command was disabled
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 20 – Release 2.0
3. You can see up to 99 events which are stored in FIFO (First in First Out) and divided into two 50-events blocks. As soon as the event 100 happens, the older 50-event bloc is automatically canceled in order to make room for other future 49 events.
4. The key pressed from any event allows to escape the event list and come back to the Event Log
screen shot. If there aren’t stored events (or the reset has just been performed), the key has no effect.
4.6.3 “Display” submenu
The submenu Display allows to see in one screen shot all the settings which will be described in the next paragraph. After entering in this submenu you will simply see them in short format as per the following example:
Display First line -3dB Off 232Rear
Second line Warn On C_8 R24
This is a brief description of the related meanings: - The caption -3dB Off means that the amplifier is working at the full rated power (1KW).
- 232Rear means that the rear RS232 connector is enabled (the front connector is therefore disabled)
- Warn On means that in case of RF power unit overheating the power will be automatically reduced to the half (250W)
- The caption C_8 inside the machine there is a counter which counts the eventual failures (e.g. overheating, excessive SWR etc.). After 8 failures the amplifier will be switched in stand-by mode
- R24 means that the counting of the failure counter is reset each 24 hours
The detailed description of all these setting is stated in the next paragraph, in which is explained how to change such these settings and other ones.
4.6.4 “Setting” submenu
The submenu Setting allows to change each of the various available settings. Part of them can be seen in one screen shot as described in the previous paragraph. This submenu is protected by a 3-digits password which is stated in the red Code Card label attached to the amplifier. The password can be uninhabited by an internal jumper (plased on the general control board).[AA3] 1. After entering in this submenu you will be prompted to enter the password
Display First line Password:
Second line 00.00.00
2. The cursor will be already positioned on the 1st digit and set to 1. By means of the and keys you can increase or decrease that figure
3. Press the key to enter the 1st digit 4. Repeat steps b) and c) for the other two digits of the password 5. If the password will be correct, the display screenshot will be recalled, however, by repeatedly
pressing the and keys, the settings will be available as well according to the following table:
Setting Description Available settings/Notes
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 21 – Release 2.0
Display Same submenu explained in the dedicated paragraph
A quick visualization of the settings which is automatically recalled after a setting has been changed
Reset Mode Defines if the failure counter should be regularly reset and the reset time.
R24 - every 24hours
Ron - At Power on
Rne – never
Exit – exit without affecting the preset value
Warning If this warning feature is set to on, the amplifier automatically reduces its power down to 500W (-3dB) in case of overheating (10 °C below the critical temperature)
Warn on – waring feature is on
Warn off – warning feature is off
Exit – exit without affecting the preset value
-3dB Manual reduction of the RF output power to the half (-3dB)
-3dB on – half power (500W)
-3dB off – full power (250W)
Exit – exit without affecting the preset value
Failure Counter Defines the number of faults which the failure counter must count before switching the amplifier into stand-by condition
C_8 – stand-by after 8 faults
C_16 – stand-by after 16 faults
Exit – exit without affecting the preset value
Time Set Allows to set the internal clock Use the and keys to increase/decrease each figure and
press the key to enter. In the minutes/time setting, figures can be increased/decreased at 10 digits
steps by keeping either the and
keys held pressed
Date Set Allows to set the internal calendar (in MM/DD/YY format) Use the and keys to
increase/decrease each figure and
press the key to enter.
RS232 Switch Switches the RS232 connection between the rear and the front connector
232Rear – rear RS232 connector
232Front – front RS232 connector
Exit – exit without affecting the preset value
Al.Mem Reset Manual reset of the event log and failure counter. It also escape the Setting menu leading back to the
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 22 – Release 2.0
Main menu
Language Selects the needed language for the LCD messages among the available languages
English is the default. The number of the available languages depend on the version
Address Allows to set up the address of the RS485 connector
Leads to Set Address screen shot
Exit Escapes the setting menu and restore the Main menu
“
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 23 – Release 2.0
5. Service
5.1 General information and warnings CAUTION: Only qualified and authorized engineers are allowed to perform the following
service operations
CAUTION: The amplifier may only be removed from the rack (rackmount) or opened and module disassembled and assembled while no voltage has been applied. Before performing any operation be sure that the AC plug is disconnected, the power switch is in OFF position and wait few minutes in order to allow the internal capacitor to discharge
CAUTION: After any disassembling/removing/replacing operation, is meant that to restore the original conditions the described operations must be carried out in the opposite order unless otherwise specified
CAUTION: The normal operation of the amplifier can restored only if all the parts are assembled and connected
5.2 Adjustments[AA4] This a description related of each adjustment trimmer available in the amplifier ordered per unit
5.2.1 PCB S3110A .02 RF Power Amplifier Unit 1.
Adjustment Test point/function Value
RV1 adjusts the gate voltage of Q1 2.3V
RV2 adjusts the gate voltage of Q2 2.3V
RV3 adjusts the gate voltage of Q3 2.3V
RV4 adjusts the gate voltage of Q4 2.3V
Adjustments of PCB S3110A.02 RF Power Amplifier Unit
5.2.2 PCB K3123A02 RF module control
Adjustment Test point/function Value
RV1 adjusts the protection against excessive SWR 200W
RV2 adjusts the unbalance protection of the power FETs BLF278 Q1-Q2
400W
RV3 adjusts the unbalance protection of the power FETs BLF278 Q3-Q4
400W
RV4 adjusts the unbalance protection of the power FETs BLF278 Q1-Q4
200W
RV5 adjusts the measurement of temperature “RF TEMP” read on the LCD display
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 24 – Release 2.0
Adjustments of PCB K3123A02 RF module control
5.2.3 PCB S3115D02– General controller
Adjustment Test point/function Value
RV1 RV1 adjusts the measurement of voltage PA.Volt. read on the LCD display (see 4.4)
RV2 adjusts the total protection against excessive SWR 100W
RV3 adjusts the measurement against excessive current PA.Curr. read on the LCD display (see 4.4)
RV4 adjusts the measurement of reflected RF power Ref. Pow. read on the LCD display (see 4.4)
RV5 adjusts the RF output power in ALC condition 1000W
RV6 adjusts the measurement of direct RF power Dir. Pow. read on the LCD display (see 4.4)
RV7 adjusts the–3dB output power 500W
Adjustments of PCB S3115D02 – General controller
5.2.4 PCB K3113C.01 - Power Supply Unit
Adjustment Test point/function Value
RV1 adjusts the power supply voltage 48V
RV2 adjusts the maximum current for the protection 50A @ 48V
RV3 adjusts the protection against over load 40A @ 48V
RV4 adjusts the temperature measurement PS.Temp. read on the LCD display (see 4.4)
Adjustments of PCB K3113C.01 - Power Supply Unit
5.3 Opening the VHF amplifier Make reference to the following pictures:
Front Panel A
A
A
A
A A
A A A1
BB
BB
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 25 – Release 2.0
Rear Panel
5.3.1 Removing the top cover
Unscrew the nine screws which fix the top cover in place
5.3.2 Removing the bottom cover
Unscrew the ten screws which fix the bottom cover in place
5.3.3 Dismounting fans 1. Use an allen key to remove the four exagonal screws which hold the handles (2 screws each handle,
marked A) to the rear panel. 2. Use an allen key to remove the hexagonal securing screws (marked B1 and B2) placed over and
below the left fan (marked on the rear external panel with a circle): the rear external panel will be free to be tilted.
3. Remove fan cables from the Power Supply board. 4. Remove the rear panel together with the two fans 5. Unscrew the four cross-head screws which lock the fan(s) on the panel (marked C and/or D) 6. Replace the fan(s) and the related vent filter(s) as described in chapter 2.3
CAUTION: At step 2. the rear external panel can just be tilted, not removed. Take care about all the internal wires.
CAUTION: The missing regular filter replacement or cleaning will activate the thermal protection.
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 26 – Release 2.0
5.3.4 Dismounting vent filter(s) 1. Use an allen key to remove the four exagonal screws which hold the vent grid located on the front
panel (marked with B) 2. Replace the filter or clean it by means of a air compressor.
5.3.5 Replacing mains AC fuses 1. Remove the two cross-head screws marked with E which hold the AC Mains Filter Unit to the rear
panel (don’t remove the four screws which hold the two AC connectors to the filter) 2. Slightly extract the AC Main Filter Unit from the rear panel (it’s not necessary to remove it) in order to
access the two fuses 3. Replace the fuse F1 (mains AC power) and/or the fuse F2 (auxiliary 2A switched output) according to
their condition.
5.3.6 Removing the AC Mains Filter Unit 1. Remove the two cross-head screws marked with E which hold the AC Mains Filter Unit to the rear
panel (don’t remove the four screws which hold the two AC connectors to the filter) 2. Carefully extract the AC Main Filter Unit from the rear panel in order to access the two connectors 3. Carefully unplug the two connectors 4. Remove the AC Mains Filter Unit
5.3.7 Removing the Controller Unit 1. Remove the top cover as over stated 2. Locate the Controller Unit and carefully unplug all its connectors 3. Unscrew the four screws which seats the PCB to the chassis 4. Remove the Controller Unit board
5.3.8 Dismounting the front LCD Display Unit 1. Remove the top cover as over stated 2. Carefully unplug the two flat cables 3. Unscrew the two exagonal nuts which hold the two LCD display PCBs to the panel 4. Remove the two PCBs together
5.3.9 Dismounting the AC Mains Power Switch 1. Remove the top cover as over stated 2. Take down note the connection of the four colored wires (brown, blue + 2 gray wires) and unplug their
Faston-type connectors from the switch 3. Press the two tabs inward which fix the switch to the front panel and keep them pressed 4. Press the switch toward the front panel and remove it
CAUTION: When restoring/replacing the new switch take care to observe the wiring connections as noted at step 2.
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 27 – Release 2.0
5.3.10 Removing the RF Board Unit 1. Remove the top and the bottom covers as over stated 2. Before going on, please remove the cover of the RF Board Unit (accessible from the top) by
unscrewing all its screws (this operation is mandatory, otherwise the RF Unit can’t be extracted). 3. Remove the nine screws near the front handles marked with A 4. Remove the screw located in the center of the front panel between the vent grid and the control panel
(marked with A1): the front panel will be free 5. Remove the front panel: only the main chassis with Display Unit and Keyboard will be left in the front
of the VHF amplifier 6. Remove the internal N-type male connector from the female-to-female pass-through transition fixed on
the rear panel which makes the RF IN connector. 7. Remove the side power supply connector (the one with four red wires), the side flat cable coming from
the Control Unit as well as the 4 wires connector coming from the RF Filter Unit. 8. Unscrew the six exagonal side screws which hold the RF Unit in place. Please note that the central
inner screw fixes the power supply voltage negative wire. 9. Loose the only the upper screw located on the rear panel marked with B1 (it’s not necessary to loose
the lower screw marked with B2). 10. Loose the two big pass-through screws located on the rear panel (marked F and G). Just loose them
(not remove), otherwise the RF filter can fall down. 11. Unscrew the N-type connector between the RF Unit and the RF Filter Unit 12. Carefully extract the RF Unit toward the front taking care not to damage the RF input cable.
CAUTION: To restore the RF Board Unit in place, strictly follow the dedicated paragraph. Do not carry on the over stated steps in the opposite order
5.3.11 Removing the RF Filter Unit 1. Perform the over stated steps to remove the RF Board Unit, apart the last step. 2. Slightly extract the RF unit toward the front just for 10 centimeters approx. in order to access the RF
filter unit 3. Completely remove the hexagonal screw B1 and two big pass-through screws F and G described at
steps 9. and 10. in the previous paragraph 4. Remove the RF angle connector which feeds the –60dB measure signal from the RF filter unit to the
front panel 5. Remove the RF Filter Unit 6. To open the RF Filter Unit, simply unscrew the twelve screws which fix its cover
Should you just need to perform a control of the RF Filter board, you can just unscrew the screws stated at step 6. without removing the filter
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 28 – Release 2.0
5.3.12 Restoring the RF Board Unit 1. Insert the RF Board unit in the slot of the front panel and locate it at the middle position (approx.) 2. Track the RF input cable inside in a path between the two fans and carefully move it to the left toward
the female-to-female N-type pass-through transition fixed on the rear panel to which it should be connected
3. Carefully slide the module toward the RF Filter Unit and slightly start to screw its N connector just to “hook” it on the RF Filter’s one
4. Push the RF Board Unit completely onto the RF Filter Unit 5. Screw completely the three screws which fix the filter to the rear panel and check that the RF Filter is
perfectly and steadily fixed 6. Screw perfectly the N connector in order to ensure the perfect RF connection between RF Board Unit
and the RF Filter 7. Screw the six side hexagonal screws described at step 8. of 5.3.10 ensuring that the central inner
screw perfectly fixes the power supply voltage negative wire 8. Perform in reverse order the steps from 2. to 7. described in 5.3.10
5.3.13 Removing the Power Supply board 1. Remove the bottom cover as over stated 2. Unplug the connectors which connects the two fans, the negative and positive power supply voltage,
the Control Unit (flat cable) and the AC mains supply (six connectors in total) 3. Unscrew the nine screws which seat the Power Supply board in the VHF amplifier
5.3.14 Replacing the Lexan Keypad/LED Unit 1. Unscrew the eight screws near the front handles 2. Unscrew the screw located in the center of the front panel between the air vent and the control panel 3. Remove the front panel (only the main chassis with display and control panel will be left in the front of
the VHF amplifier) 4. Unplug the flat connector which connects the Lexan Keypad/LED Unit with the LCD Display Unit 5. Remove the AC Mains Power Switch ad described in 5.3.9 6. Remove the BNC connector from the front panel (it feeds the –60dB measure signal from the RF filter
unit to the front panel) 7. Remove the female-to-female pass-through BNC transition from the front panel by unscrewing the
related nut 8. Carefully remove the Lexan Keypad/LED Unit (it is jammed onto the front panel by means of its
adhesive tape) 9. Perfectly clean the surface where the old Lexan Keypad/LED Unit was jammed in order to ensure a
perfect adherence of the new one 10. Peel off the protection film from the new Lexan Keypad/LED Unit 11. Stick the new Lexan Keypad/LED Unit onto the front panel making reference on the three holes for the
BCN transition, the RS232 connector as well as the AC Mains Power Switch
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 29 – Release 2.0
DEVIATIONS FOR FM BROADCASTING MODEL: VL1000 PLUS
COUNTRY FM Broadcasting Deviations from ERC Decisions introduced and other comments
AUSTRIA Yes Individual licence is required BELGIUM Yes Individual licence is required DENMARK Yes Individual licence is required FINLAND Yes Individual licence is required FRANCE Yes Individual licence is required GERMANY Yes Individual licence is required GREECE Yes Individual licence is required IRELAND Yes Individual licence is required ITALY Yes Individual licence is required LUXEMBOURG Yes Individual licence is required NETHERLANDS Yes Individual licence is required NORWAY Yes Individual licence is required PORTUGAL Yes Individual licence is required SPAIN Yes Individual licence is required SWEDEN Yes Individual licence is required SWITZERLAND Yes Individual licence is required UNITED KINGDOM Yes Individual licence is required
RESTRIZIONI ALL'USO PER APPARATI FM BROADCASTINGMODELLO: VL1000 PLUS
STATO Introduzione FM Broadcasting
Restrizioni all'uso
AUSTRIA Sì Richiesta la licenza individuale BELGIO Sì Richiesta la licenza individuale DANIMARCA Sì Richiesta la licenza individuale FINLANDIA Sì Richiesta la licenza individuale
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 30 – Release 2.0
FRANCIA Sì Richiesta la licenza individuale GERMANIA Sì Richiesta la licenza individuale GRECIA Sì Richiesta la licenza individuale IRLANDA Sì Richiesta la licenza individuale ITALIA Sì Richiesta la licenza individuale LUSSEMBURGO Sì Richiesta la licenza individuale NORVEGIA Sì Richiesta la licenza individuale OLANDA Sì Richiesta la licenza individuale PORTOGALLO Sì Richiesta la licenza individuale REGNO UNITO Sì Richiesta la licenza individuale SPAGNA Sì Richiesta la licenza individuale SVEZIA Sì Richiesta la licenza individuale SVIZZERA Sì Richiesta la licenza individuale
Restrictions à l'usage pour FM Broadcasting Modèle: VL1000 PLUS
PAYS FM Broadcasting Correction de la directive ERC presentè et autre commentaires
ALLEMAGNE Oui Licence individuelle demandée ANGLETERRE Oui Licence individuelle demandée AUTRICHE Oui Licence individuelle demandée BELGIQUE Oui Licence individuelle demandée DANEMARK Oui Licence individuelle demandée ESPAGNE Oui Licence individuelle demandée FINLANDE Oui Licence individuelle demandée FRANCE Oui Licence individuelle demandée GRECE Oui Licence individuelle demandée IRLANDE Oui Licence individuelle demandée ITALIE Oui Licence individuelle demandée LUXEMBOURG Oui Licence individuelle demandée NORVEGE Oui Licence individuelle demandée PAY-BAS Oui Licence individuelle demandée PORTUGAL Oui Licence individuelle demandée SUEDE Oui Licence individuelle demandée SUISSE Oui Licence individuelle demandée
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 31 – Release 2.0
RESTRICCIONES AL USO DE FM BROADCASTING MODELO: VL1000 PLUS
PAIS FM Broadcasting Restricciones al uso introducida y otros comentarios
ALEMANIA Si Requiere licencia individual AUSTRIA Si Requiere licencia individual BÉLGICA Si Requiere licencia individual DINAMARCA Si Requiere licencia individual ESPAÑA Si Requiere licencia individual FINLANDIA Si Requiere licencia individual FRANCIA Si Requiere licencia individual GRAN BRETAÑA Si Requiere licencia individual GRECIA Si Requiere licencia individual HOLANDA Si Requiere licencia individual IRLANDA Si Requiere licencia individual ITALIA Si Requiere licencia individual LUXEMBURGO Si Requiere licencia individual NORUEGA Si Requiere licencia individual PORTUGAL Si Requiere licencia individual SUECIA Si Requiere licencia individual SUIZA Si Requiere licencia individual
Nutzungshinweis zu FM BROADCASTING MODELL: VL1000 PLUS
LAND FM Broadcasting eingeführt
Abweichungen von ERC Vorschriften und Kommentare
BELGIEN Ja Individuelle Lizenz erforderlich DÄNEMARK Ja Individuelle Lizenz erforderlich DEUTSCHLAND Ja Individuelle Lizenz erforderlich
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 32 – Release 2.0
FINNLAND Ja Individuelle Lizenz erforderlich FRANKREICH Ja Individuelle Lizenz erforderlich GRIECHENLAND Ja Individuelle Lizenz erforderlich GROßBRITANNIEN Ja Individuelle Lizenz erforderlich IRLAND Ja Individuelle Lizenz erforderlich ITALIEN Ja Individuelle Lizenz erforderlich LUXEMBURG Ja Individuelle Lizenz erforderlich NIEDERLANDE Ja Individuelle Lizenz erforderlich NORWEGEN Ja Individuelle Lizenz erforderlich ÖSTERREICH Ja Individuelle Lizenz erforderlich PORTUGAL Ja Individuelle Lizenz erforderlich SPANIEN Ja Individuelle Lizenz erforderlich SCHWEDEN Ja Individuelle Lizenz erforderlich SCHWEIZ Ja Individuelle Lizenz erforderlich
DESVIOS PARA FM BROADCASTING MODELO: VL1000 PLUS
PAÍS FM Broadcasting Desvios estabelecidos pelo ERC
introduzido e outras notas ALEMANHA Sim Exigida licença individual AUSTRIA Sim Exigida licença individual BÉLGICA Sim Exigida licença individual DINAMARCA Sim Exigida licença individual ESPANHA Sim Exigida licença individual FINLÂNDIA Sim Exigida licença individual FRANÇA Sim Exigida licença individual GRÉCIA Sim Exigida licença individual HOLANDA Sim Exigida licença individual IRLANDA Sim Exigida licença individual ITALIA Sim Exigida licença individual LUXEMBURGO Sim Exigida licença individual NORUEGA Sim Exigida licença individual PORTUGAL Sim Exigida licença individual REINO UNIDO Sim Exigida licença individual SUÉCIA Sim Exigida licença individual SUÍÇA Sim Exigida licença individual
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 33 – Release 2.0
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
S3109B.SCH
POWER SPLITTER V1000 PLUS
META SYSTEM SpA
A
1 1Thursday, April 19, 2001
Title
Size Document Number Rev
Date: Sheet of
R1
50
40W
R3
50
40W
KDI
R4
50
40W
KDI
R2
50
40W
C1
6P8
POWER SPLITTER
3dB COUPLER
3dB COUPLER
IN
TO AB11
TO AB22
TO AB33
TO AB44
AA
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 34 – Release 2.0
LC/B
S3109S3109
LS/B
17115.75 115.25
111.75111.25 25
14.2
544
.25
73.2
5
3.2 n 15
1 n 19
FORATURA C.S. S3109A - VISTA LATO COMPONENTI
17
44.2
5
6p8
C1
R1 R2
R4 R3
POWER SPLITTER
WW
WW
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 35 – Release 2.0
POWER SPLITTER VL1000 PLUS Revised: Thursday, April 19, 2001 S3109B.SCH Revision: ?
META SYSTEM SpA
Bill Of Materials October 9,2001 11:56:34
Page1
Comp. No. Stock No. Designation Manufacturer Designation ______________________________________________________________________________________
C1 C02056 6P8 HF MURATA ERE22X5C2H6R8CD13LR1 R09616 50 40W ISO KDI PPR800-40-3-50-5 R2 R09616 50 40W ISO KDI PPR800-40-3-50-5 R3 R09615 50 40W TER KDI PPT800-40-3-50-5 R4 R09615 50 40W TER KDI PPT800-40-3-50-5
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 36 – Release 2.0
L22
BOBINA
13SP
C14
470P
1206
C53
0U1
TRD
100V
X7R
R6
680
1206
C13
10N
X
C18
180P
R5
6K8
1206
R40
27
3W
C56
0U1
TRDX7R
C33
1N
R41K5
1206
D3
PMLL4148
R19
220
1206
D1
PMLL4148
R30
680
1206
RV1
1K
CW
R47
6.8
2W
C12
100P
COG
R3
100
1206
C371N
HF
R38
27
3W
R22
680
1206
C27
0U1
TRD
100V
X7R
RK1A
NTC
TRD
15K
Q2
BLF2782
13
R16
820
1206
C31
180P
R8
220
1206
D4PMLL4148
C461N
D5
PMLL4148
Q4
BLF2782
13
C57
0U1
TRDX7R
C41470P
1206
R11680
1206
C55
0U1
TRDX7RR48
6.8
2W
C50
1N
HF
T2
TRASF-OUT-1KW
C28
470P
1206
D8PMLL4148
Q3
BLF2782
13
L24
BOBINA
5SP
C44
180P
C541N
COG
2
13
C15470P
1206
R24820
1206
D7
PMLL4148
C39
0U1
TRD
100V
X7R
DZ2
6V8
SOD80C
R27
220
1206
T4
TRASF-OUT-1KW
2
13
R18
680
1206
C58
0U1
TRDX7R
L8
FERRITE
8X3,5X22
L14
FERRITE
8X3,5X22
R13
100
1206
L9
BOBINA
10SP
R201K8
1206
L12
BOBINA
5SP
R25
6K8
1206
IC1
LM335
TRD
R21
100
1206
RK4ANTC
TRD
15K
L16BOBINA
13SP
R32
820
1206
R41
220
1206
R42
220
1206
R33
6K8
1206
R43
220
1206
DZ3
6V8
SOD80C
L20
FERRITE
8X3,5X22
R44
220
1206
C23
22P
C40
0U1
TRD
100V
X7R
L1
BOBINA
5SP
C19
56P
C17
100P
COG
C1
180P
R31
1K5
1206
T6
TRASF-OUT-1KW
C2
56P
R29
100
1206
L15
BOBINA
10SP
T7
TRASF-IN-1KW
C21
1N
HF
L13
15UH
L7
15UH
R1
27
3W
R26680
1206
RK3A
NTC
TRD
15K
C22
10P
DZ4
6V8
SOD80C
L6
15UH
L21
BOBINA
10SP
C36
22P
C32
56P
Q1
BLF2782
13
2
13
C31N
HF
R15
1K5
1206
C4
1N
HF
R281K8
1206
C43
100P
COG
L18
BOBINA
5SP
C51
0U1
TRD
100V
X7R
L2
BOBINA
3SPC34
1N
HF
2
13
L11
BOBINA
3SP
C6
10P
T8
TRASF-OUT-1KW
C722P
L3
BOBINA
13SP
C35
10P
C30
100P
COG
RV2
1K
CW
C49
22P
T3
TRASF-IN-1KW
C45
56P
C38
0U1
TRD
100V
X7R
R2
27
3W
C47
1N
HF
RK2ANTC
TRD
15K
C25
0U1
TRD
100V
X7R
R17
6K8
1206 L19
15UH
T1
TRASF-IN-1KW
R34
680
1206
L17
BOBINA
3SP
R45
6.8
2W
R121K8
1206
L10
BOBINA
13SP
C48
10P
C52
0U1
TRD
100V
X7R
R35
27
3W
R231K5
1206
D6
PMLL4148
T5
TRASF-IN-1KW
RV3
1K
CW
L23
BOBINA
3SP
L4
BOBINA
10SP
C8
1N
L5
FERRITE
8X3,5X22
R39
27
3W
C1610N
X
C9
0U1
TRD
100V
X7R
R9
220
1206
C10
0U1
TRD
100V
X7R
C4210N
X
C201N
C11
0U1
TRD
100V
X7R
R10820
1206
R46
6.8
2W
C26
0U1
TRD
100V
X7R
R14
680
1206
C24
1N
HF
R37
27
3W
R7
1K8
1206
R36
27
3W
C29
10N
X
D2
PMLL4148
RV4
1K
CW
DZ1
6V8
SOD80C
AMP1
1KW POWER MODULE AMPLIFIER
I1
I2
O1
O3
O2
a mano con la
bobina costruita
*
*
resistenza R49
AMP2
I1
I2
O1
O3
O2
a mano con la
bobina costruita
*
*
resistenza R46
AMP3
I1
I2
O1
O3
O2
a mano con la
bobina costruita
*
*
resistenza R47
AMP4
I1
I2
O1
O3
O2
a mano con la
bobina costruita
*
*
resistenza R48
FROM AD1 10
9TO AD9
1FROM AA1
11FROM AD2
2FROM AA2
14
FROM AD8
FROM AD3
12
FROM AA3
3
FROM AD4
13
FROM AA4
4
TO AC3
7
8
TO AC4
5
TO AC1
6
TO AC2
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 37 – Release 2.0
H2 H3 H4
H5H6
H7 H8
H9 H10 H11 H12 H13
H14
R8
L6DZ1
R7 C14
D2
R3R6
D1
RV1
R4
C13
R10
R5
RK1
R11
C12
C1
C2
C8
C4
C6
C7
C3
C9
C10
C11
L5
L4
L3
L2
L1
T1
T2
Q1
R9
L7DZ2
R12
C15
D3
R13R14 D4
RV2
R15
C16
R16
R17
RK2
R18
C17
C18
C19
C20
C21
C22
C23
C24
C25
C26
C27
L8
L9
L10
L11
L12
T3
T4
Q2
R19
L13DZ3
R20
C28
D5
R21R22
D6
RV3
R23
C29
R24
R25
RK3
R26
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C40
L14
L15
L16
L17
L18
T5
T6
Q3
H15
R27
L19DZ4
R28
C41
D7
R29R30 D8
RV4
R31
C42
R32
R33
RK4
R34
C43
C44
C45
C46
C47
C48
C49
C50
C51
C52 C53
L20
L21
L22
L23
L24
T7
T8
Q4
C54
R1
R2
R35
R36
R37
R38
R39
R40
H20 H21 H22 H23
R41 R42 R43 R44
R45
L25
C55
R46
L26
C56
R47
L27
C57
R48
L28
C58
META SYSTEM PROPERTY ALL RIGHT RESERVED ART. 1151-1/2/3
CODICE:
TITOLO:
DATA:
IL TECNICO PROGETTISTA:
IL TECNICO DISEGNATORE:
SCALA:
___________________________
___________________________
RIFERIM. X:
R
METASYSTEM
R
HFID1
HANU1
HANU2
HFID2
HANU3
HANU4
IC1
RK1A RK2A RK3A RK4A
CIRCUITO AMPLIFICATORE VL1000 PLUS
CAVALCABUE
1:1
S3110A01 28-02-01
MOTTI
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 38 – Release 2.0
AMPLIFICATORE VL1000 PLUS Revised: Thursday, April 19, 2001 S3110A01.SCH Revision: ?
META SYSTEM S.p.A. Property all rights reserved art.1151-1/2/3 Il tecnico progettista: Allegri M. Il tecnico disegnatore: Scorticati S.
Bill Of Materials October 9,2001 11:54:16
Page1
Comp. No. Stock No. Designation Manufacturer Designation
C1 C02124 180P HF MURATA ERE22X5C1D181JD13BC2 C02100 56P HF MURATA ERE22X5C2H560JD13LC3 C02160 1N HF MURATA ERE22X5C1H102JD13LC4 C02160 1N HF MURATA ERE22X5C1H102JD13LC6 C02064 10P HF MURATA ERE22X5C2H100JD13LC7 C02080 22P HF MURATA ERE22X5C2H220JD13LC8 C02160 1N HF MURATA ERE22X5C1H102JD13LC9 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C10 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C11 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C12 C3310B 100P 0805 COG MURATA GRM40COG101J50 C13 C3510F 10N 0805 X MURATA GRM40X7R103K50 C14 C3347S 470P 1206 X MURATA GRM42X7R471K50 C15 C3347S 470P 1206 X MURATA GRM42X7R471K50 C16 C3510F 10N 0805 X MURATA GRM40X7R103K50 C17 C3310B 100P 0805 COG MURATA GRM40COG101J50 C18 C02124 180P HF MURATA ERE22X5C1D181JD13BC19 C02100 56P HF MURATA ERE22X5C2H560JD13LC20 C02160 1N HF MURATA ERE22X5C1H102JD13LC21 C02160 1N HF MURATA ERE22X5C1H102JD13LC22 C02064 10P HF MURATA ERE22X5C2H100JD13LC23 C02080 22P HF MURATA ERE22X5C2H220JD13LC24 C02160 1N HF MURATA ERE22X5C1H102JD13LC25 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C26 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C27 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C28 C3347S 470P 1206 X MURATA GRM42X7R471K50 C29 C3510F 10N 0805 X MURATA GRM40X7R103K50 C30 C3310B 100P 0805 COG MURATA GRM40COG101J50 C31 C02124 180P HF MURATA ERE22X5C1D181JD13BC32 C02100 56P HF MURATA ERE22X5C2H560JD13LC33 C02160 1N HF MURATA ERE22X5C1H102JD13L
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 39 – Release 2.0
C34 C02160 1N HF MURATA ERE22X5C1H102JD13LC35 C02064 10P HF MURATA ERE22X5C2H100JD13LC36 C02080 22P HF MURATA ERE22X5C2H220JD13LC37 C02160 1N HF MURATA ERE22X5C1H102JD13LC38 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C39 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C40 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C41 C3347S 470P 1206 X MURATA GRM42X7R471K50 C42 C3510F 10N 0805 X MURATA GRM40X7R103K50 C43 C3310B 100P 0805 COG MURATA GRM40COG101J50 C44 C02124 180P HF MURATA ERE22X5C1D181JD13BC45 C02100 56P HF MURATA ERE22X5C2H560JD13LC46 C02160 1N HF MURATA ERE22X5C1H102JD13LC47 C02160 1N HF MURATA ERE22X5C1H102JD13LC48 C02064 10P HF MURATA ERE22X5C2H100JD13LC49 C02080 22P HF MURATA ERE22X5C2H220JD13LC50 C02160 1N HF MURATA ERE22X5C1H102JD13LC51 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C52 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C53 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C54 C3410B 1N 0805 COG MURATA GRM40COG102J50 C55 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C56 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C57 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 C58 C01765 0U1 TRD 100V X SIEMENS B37987F1104K100 D1 D05106 PMLL4148 PHILIPS PMLL4148 D2 D05106 PMLL4148 PHILIPS PMLL4148 D3 D05106 PMLL4148 PHILIPS PMLL4148 D4 D05106 PMLL4148 PHILIPS PMLL4148 D5 D05106 PMLL4148 PHILIPS PMLL4148 D6 D05106 PMLL4148 PHILIPS PMLL4148 D7 D05106 PMLL4148 PHILIPS PMLL4148 D8 D05106 PMLL4148 PHILIPS PMLL4148 DZ1 D01685 6V8 SOD80C PHILIPS BZV55C6V8 DZ2 D01685 6V8 SOD80C PHILIPS BZV55C6V8 DZ3 D01685 6V8 SOD80C PHILIPS BZV55C6V8 DZ4 D01685 6V8 SOD80C PHILIPS BZV55C6V8 IC1 I00318 LM335 TRD NATIONAL LM335AZ L1 M03084 BOBINA TRD 5SP METASYSTEM M03084 L2 M03047 BOBINA TRD 3SP METASYSTEM M03047 L3 M03254 BOBINA TRD 13SP METASYSTEM M03254 L4 M03186 BOBINA TRD 10SP METASYSTEM M03186 L5 M01035 FERRITE TRD 8X3,5X22 NEOSID GMBH F2A8X3.5X22 L6 M12150 15UH SIEMENS B82422-A1153-K100 L7 M12150 15UH SIEMENS B82422-A1153-K100 L8 M01035 FERRITE TRD 8X3,5X22 NEOSID GMBH F2A8X3.5X22 L9 M03186 BOBINA TRD 10SP METASYSTEM M03186 L10 M03254 BOBINA TRD 13SP METASYSTEM M03254 L11 M03047 BOBINA TRD 3SP METASYSTEM M03047
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 40 – Release 2.0
L12 M03084 BOBINA TRD 5SP METASYSTEM M03084 L13 M12150 15UH SIEMENS B82422-A1153-K100 L14 M01035 FERRITE TRD 8X3,5X22 NEOSID GMBH F2A8X3.5X22 L15 M03186 BOBINA TRD 10SP METASYSTEM M03186 L16 M03254 BOBINA TRD 13SP METASYSTEM M03254 L17 M03047 BOBINA TRD 3SP METASYSTEM M03047 L18 M03084 BOBINA TRD 5SP METASYSTEM M03084 L19 M12150 15UH SIEMENS B82422-A1153-K100 L20 M01035 FERRITE TRD 8X3,5X22 NEOSID GMBH F2A8X3.5X22 L21 M03186 BOBINA TRD 10SP METASYSTEM M03186 L22 M03254 BOBINA TRD 13SP METASYSTEM M03254 L23 M03047 BOBINA TRD 3SP METASYSTEM M03047 L24 M03084 BOBINA TRD 5SP METASYSTEM M03084 Q1 T01040 BLF278 TRD PHILIPS BLF278 Q2 T01040 BLF278 TRD PHILIPS BLF278 Q3 T01040 BLF278 TRD PHILIPS BLF278 Q4 T01040 BLF278 TRD PHILIPS BLF278 R1 R04104 27 TRD 3W PHILIPS 2322 195 13279 R2 R04104 27 TRD 3W PHILIPS 2322 195 13279 R3 R23100 100 1206 SIEMENS B54103A1 101J60 R4 R24150 1K5 1206 SIEMENS B54103A1 152J60 R40 R04104 27 TRD 3W PHILIPS 2322 195 13279 R41 R23220 220 1206 SIEMENS B54103A1 221J60 R42 R23220 220 1206 SIEMENS B54103A1 221J60 R43 R23220 220 1206 SIEMENS B54103A1 221J60 R44 R23220 220 1206 SIEMENS B54103A1 221J60 R45 R04061 6R8 TRD 2W PIHER EO-02 6,8 OHM R46 R04061 6R8 TRD 2W PIHER EO-02 6,8 OHM R47 R04061 6R8 TRD 2W PIHER EO-02 6,8 OHM R48 R04061 6R8 TRD 2W PIHER EO-02 6,8 OHM R5 R24680 6K8 1206 SIEMENS B54103A1 682J60 R6 R23680 680 1206 SIEMENS B54103A1 681J60 R7 R24180 1K8 1206 SIEMENS B50103A1 182J60 R8 R23220 220 1206 SIEMENS B54103A1 221J60 R9 R23220 220 1206 SIEMENS B54103A1 221J60 R10 R23820 820 1206 SIEMENS B54103A1 821J60 R11 R23680 680 1206 SIEMENS B54103A1 681J60 R12 R24180 1K8 1206 SIEMENS B50103A1 182J60 R13 R23100 100 1206 SIEMENS B54103A1 101J60 R14 R23680 680 1206 SIEMENS B54103A1 681J60 R15 R24150 1K5 1206 SIEMENS B54103A1 152J60 R16 R23820 820 1206 SIEMENS B54103A1 821J60 R17 R24680 6K8 1206 SIEMENS B54103A1 682J60 R18 R23680 680 1206 SIEMENS B54103A1 681J60 R19 R23220 220 1206 SIEMENS B54103A1 221J60 R20 R24180 1K8 1206 SIEMENS B50103A1 182J60 R21 R23100 100 1206 SIEMENS B54103A1 101J60 R22 R23680 680 1206 SIEMENS B54103A1 681J60 R23 R24150 1K5 1206 SIEMENS B54103A1 152J60
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 41 – Release 2.0
R24 R23820 820 1206 SIEMENS B54103A1 821J60 R25 R24680 6K8 1206 SIEMENS B54103A1 682J60 R26 R23680 680 1206 SIEMENS B54103A1 681J60 R27 R23220 220 1206 SIEMENS B54103A1 221J60 R28 R24180 1K8 1206 SIEMENS B54103A1 182J60 R29 R23100 100 1206 SIEMENS B54103A1 101J60 R30 R23680 680 1206 SIEMENS B54103A1 681J60 R31 R24150 1K5 1206 SIEMENS B54103A1 152J60 R32 R23820 820 1206 SIEMENS B54103A1 821J60 R33 R24680 6K8 1206 SIEMENS B54103A1 682J60 R34 R23680 680 1206 SIEMENS B54103A1 681J60 R35 R04104 27 TRD 3W PHILIPS 2322 195 13279 R36 R04104 27 TRD 3W PHILIPS 2322 195 13279 R37 R04104 27 TRD 3W PHILIPS 2322 195 13279 R38 R04104 27 TRD 3W PHILIPS 2322 195 13279 R39 R04104 27 TRD 3W PHILIPS 2322 195 13279 RK1A R05910 NTC TRD 15K MURATA NTH5D153KA RK2A R05910 NTC TRD 15K MURATA NTH5D153KA RK3A R05910 NTC TRD 15K MURATA NTH5D153KA RK4A R05910 NTC TRD 15K MURATA NTH5D153KA RV1 R14100 1K 1G TOCOS G4BT1KOHM RV2 R14100 1K 1G TOCOS G4BT1KOHM RV3 R14100 1K 1G TOCOS G4BT1KOHM RV4 R14100 1K 1G TOCOS G4BT1KOHM T1 XF7L24 TRASF-IN-1KW TRD METASYSTEM XF7L24 T2 XF7L61 TRASF-OUT-1KW TRD METASYSTEM XF7L61 T3 XF7L24 TRASF-IN-1KW TRD METASYSTEM XF7L24 T4 XF7L61 TRASF-OUT-1KW TRD METASYSTEM XF7L61 T5 XF7L24 TRASF-IN-1KW TRD METASYSTEM XF7L24 T6 XF7L61 TRASF-OUT-1KW TRD METASYSTEM XF7L61 T7 XF7L24 TRASF-IN-1KW TRD METASYSTEM XF7L24 T8 XF7L61 TRASF-OUT-1KW TRD METASYSTEM XF7L61
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 42 – Release 2.0
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
S3111B.SCH
ACC. OUT VL1000 PLUS
METASYSTEM S.p.A
PROPERTY ALL RIGHTS RESERVED ART.1151 /1/2/3
IL TECNICO PROGETTISTA: MOTTI ENZO
IL TECNICO DISEGNATORE: SCORTICATI S.
B
1 1Thursday, April 19, 2001
Title
Size Document Number Rev
Date: Sheet of
C8
1PF
C9
18PF
D5
D6
PMLL4148
C10
1N
R4
50
TRD
250W
ISO
EC1
N-FEM-PAN
C11
1N
R8
50
TRD
250W
R9
470
1206
R10
82
1206
R1
50
TRD
250W
C12
33P
C1
1PF
D7
1N6263
C2
18PF
R11
100
1206
D1
D2
PMLL4148
R2
470
1206
C6
1PF
C3
1N
R7
100
R3
50
TRD
250W
ISO
C7
1N
C4
39PF
C5
1N
R5
100K
D3
D4
PMLL4148
R6
100K
OUTPUT COMBINER
FROM AB5 1
FROM AB6 2
FROM AB7 3
FROM AB8 4
TO AD5
5
TO AD7
7
TO AD6
6
TO AD12
8
AC
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 43 – Release 2.0
R
SYSTEMMETA
R3 R4
D3
D4
R8
D4D3
R1D1
D2
OUT
PUT C
OM
BINE
R
LATO SALDATURE C.S. S3111B
S3111B
77.5
30
105.5
85.75
248
153
179 69
116.536.5
1.5
3.5
27.2
5
11
27.25
11
26
11 11
FORATURA LATO SALDATURE C.S. S3111B
2
250W50
250W50
250W50
PASS PASS
TERM TERM
50250W
LATO COMPONENTI C.S. S3111B
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 44 – Release 2.0
ACC. OUT VL1000 PLUS Revised: Thursday, April 19, 2001 S3111B.SCH Revision:
METASYSTEM S.p.A PROPERTY ALL RIGHTS RESERVED ART.1151 /1/2/3 IL TECNICO PROGETTISTA: MOTTI ENZO IL TECNICO DISEGNATORE: SCORTICATI S.
Bill Of Materials October 9,2001 12:02:31
Page1
Comp. No. Stock No. Designation Manufacturer Designation
C1 C02016 1PF HF MURATA ERE22X5C2H1R0CD13L C2 C02076 18PF HF MURATA ERE22X5C2H180JD13L C3 C3410P 1N 1206 COG MURATA GRM42COG102K50 C4 C02092 39PF HF MURATA ERE22X5C2H390JD13L C5 C02160 1N HF MURATA ERE22X5C1H102JD13L C6 C02016 1PF HF MURATA ERE22X5C2H1R0CD13L C7 C02160 1N HF MURATA ERE22X5C1H102JD13L C8 C02016 1PF HF MURATA ERE22X5C2H1R0CD13L C9 C02076 18PF HF MURATA ERE22X5C2H180JD13L C10 C3410P 1N 1206 COG MURATA GRM42COG102K50 C11 C3410P 1N 1206 COG MURATA GRM42COG102K50 C12 C3233P 33P 1206 COG MURATA GRM42COG330J50 D1 D05106 PMLL4148 PHILIPS PMLL4148 D2 D05106 PMLL4148 PHILIPS PMLL4148 D3 D05106 PMLL4148 PHILIPS PMLL4148 D4 D05106 PMLL4148 PHILIPS PMLL4148 D5 D05106 PMLL4148 PHILIPS PMLL4148 D6 D05106 PMLL4148 PHILIPS PMLL4148 D7 D00807 1N6263 TRD HOT-CAR. ST 1N6263 EC1 E04520 N-FEM-PAN TRD UG-58-A/U BELCO UG-58-A/U R1 R09617 50 TRD 250W KDI PTT975-250-3-50-5 R2 R23470 470 1206 SIEMENS B54103A1 471J60 R3 R09618 50 TRD 250W KDI PPR975-250-3-50-5 R4 R09618 50 TRD 250W KDI PPR975-250-3-50-5 R5 R01510 100K TRD 1% ROY MF25 100KOHM F R6 R01510 100K TRD 1% ROY MF25 100KOHM F R7 R23101 100 SIEMENS B54103A1 101J60 R8 R09617 50 TRD 250W KDI PTT975-250-3-50-5 R9 R23470 470 1206 SIEMENS B54103A1 471J60 R10 R22820 82 1206 SIEMENS B54103A1 820J60 R11 R23100 100 1206 SIEMENS B54103A1 101J60
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 45 – Release 2.0
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
S3119A.SCH
FILTRO RF VU310E1/VU305E1
META SYSTEM S.p.A.
Property all rights reserved art.1151-1/2/3
Resp. tecnico: Motti E.
Disegnatore: Scorticati S.
A
1 1Thursday, April 19, 2001
Title
Size Document Number Rev
Date: Sheet of
D2
1N6263
EC3
C6
1N
C7
22P L6
0UH68
R4
100
R3
470
EC1 L1 L2 L3 L4 L5
C1 C2
R1
47
C3
82P
D1
1N6263
C4
1N
C5
22P
R2
470
EC2
R5
100
L7
0UH68
-60dB
OUT
DIR
REF
PRINTER CAPACITOR
1 TO AD10
2 TO AD10
AE
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 46 – Release 2.0
S3119 LC/A
FORATURA SF3057
N. 14 FORI DIAM 3.25mm
FILT
ER A
ND D
IREC
TIONA
L C
OUP
LER
CIR
CUI
T
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 47 – Release 2.0
FILTRO RF VL1000 PLUS Revised: Thursday, April 19, 2001 S3119A.SCH Revision: ?
META SYSTEM S.p.A. Property all rights reserved art.1151-1/2/3 Resp. tecnico: Motti E. Disegnatore: Scorticati S.
Bill Of Materials October 9,2001 10:47:12
Page1
Comp. No. Stock No. Designation Manufacturer Designation
C1 PDEL HH C2 PDEL HH C3 C1282C 82P TRD 63V PHILIPS 222264 210 829 C4 C02160 1N HF MURATA ERE22X5C1H102JD13L C5 C02080 22P HF MURATA ERE22X5C2H220JD13L C6 C02160 1N HF MURATA ERE22X5C1H102JD13L C7 C02080 22P HF MURATA ERE22X5C2H220JD13L D1 D00807 1N6263 TRD HOT-CAR. ST 1N6263 D2 D00807 1N6263 TRD HOT-CAR. ST 1N6263 EC1 E04519 N-MAS-PAN TRD KAIJAK B0900-N2A5 EC2 E04572 7/16FEM-PAN TRD CPE SP12.000 EC3 E04541 BNC-FEM-PAN TRD NL INDUS. 14277 L1 XF7L44 BOB-2SP-DIAM-14 TRD METASYSTEM XF7L44 L2 XF7L45 BOB-4SP-DIAM-14 TRD METASYSTEM XF7L45 L3 XF7L46 BOB-5SP-DIAM-14 TRD METASYSTEM XF7L46 L4 XF7L45 BOB-4SP-DIAM-14 TRD METASYSTEM XF7L45 L5 XF7L44 BOB-2SP-DIAM-14 TRD METASYSTEM XF7L44 L6 M00010 0UH68 TRD 0W25 SIEMENS B78108T3681K L7 M00010 0UH68 TRD 0W25 SIEMENS B78108T3681K R1 R00201 47 TRD ROY CR25PS 47OHMJ R2 R00321 470 TRD ROY CR25PS 470OHMJ R3 R00321 470 TRD ROY CR25PS 470OHMJ R4 R23100 100 1206 SIEMENS B54103A1 101J60 R5 R23100 100 1206 SIEMENS B54103A1 101J60
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 48 – Release 2.0
FROM AE1 10
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
K3123A01.SCH
CONTROLLER MOD. RF VL1000/VL500 PLUS
META SYSTEM Sp A
PROPERTY ALL RIGHTS RESERVED ART. 1151-1/2/3
IL TECNICO PROGETTISTA:MOTTI ENZO
IL TECNICO DISEGNATORE:SCORTICATI STEFANO
B
1 1Tuesday, April 10, 2001
Title
Size Document Number Rev
Date: Sheet of
PP1U2A
MC33079D
3
2
1
411
+
-
R3315K
R36K8
1%
FER5
C26
10N
X
U2D
MC33079D
12
13
14-
+
PP10
FER6
C12
0U1
X
DZ2BZX84-15V
2
3
1
Q2A
MJD42
D11
BAV99
2
3
1
R51
1K5RV410K
CW
R25
2K2
U1ALM358
3
2
1
48
+
-
D12
BAV70
2
3
1
FER4
R441K
1%
U2B
MC33079D
5
6
7+
-
C231N
TRDR27
10K
C3
0U1
X
D7
BAW56
2
3
1
U2CMC33079D
10
9
8-
+
R34
10K
C24
1N
TRD
R32
10K
1206
R28
10K
FER2
L2
15UH
C140U1
X
L3
15UH
R31
10K
D13
BAV99
2
3
1
R30470
Q3A
MJD42
C37
1N
R1
4K22
1%
R210K
1%
C30
1N
C25
0U1
X
FER7
C1150P
R13
100
D4SM4004
R4
10K
1%
DZ1
9V1
TRD
1W
L4
15UH
R5
4K7
C330U1
X
C2
1N
X
U1B
LM358
5
6
7
+
-
R7
10K
R1710
1206
R6
10K
R15
22
1206
R9
100K
C5
150P
R8
1M
C40U1
X
C27
1N
R16
1K
1206
R102K7
R5210K
1%
R11
8K2
R12
2K2
PP6
R53
12K4
1206
1%
RV110K
CW
C381N
PP7
C610U
16V
PP2
R18
10K
C15
0U1
X
U5BLM393
5
6
7-
+
L6A
15UH
TRD
R19
10K
R20
10K
D10
BAV99
2
3
1
C9
10N
X
C1010N
X
C1110N
X
RV2
22K
CW
U5A
LM393
3
2
1
48
+
-
R46
22K
EC1
2X5PMAS90
1 2
3 4
5 6
7 8
9 10
R21
4K7
R42
1K3
1%
R22
4K7
C29
1N
R48
1K
D5
BAV99
2
3
1
C19
10N X
R4710K
C36
1N
R23
330K
PP8
U3
LM336
N.C1
N.C2
N.C3
-4
ADJ5
N.C6
N.C7
+8C34
1N
C31
1N
L7A 15UH
TRD
L8
15UH
R24
4K7
L5
15UH
R26
100K
PP4
D14
BAW56
2
3
1
R451K3
1%
C13
0U1
X
L1
15UH
L9
15UH
C17
10N
X
R40
1K2
R49
1K
1%
R41
1K3
1%
PP5
R43
4K7
1%
FER3
C320U1
100V
X7R
R50
3K83
0805
1%
PP9
RV5
10K
CW
RV3
22KCW
U4
LM336
N.C1
N.C2
N.C3
-4
ADJ5
N.C6
N.C7
+8
R29
470K
R14
2M2
PP3
FER8
C710N
X
C2110U
35V
D5
C160U1
X
C8
10U
35V
D5
Q1
BC807
C35
1N
EC2
MAT4PMAS90
1
2
3
4
1
C28
1N
FER1
+ 15V
+ 15V
+ 15V
+ 15V
+ 15V
-15V
+ 15V
VREF+ 15V + 15V
+ 15V
-15V
+ 15V
-15V
-15V
+ 15V
VREF
V CONTROL
WR
-15V
EXC. SWR/UNB
REF
DIR
PA TEMP
REF
UMB1
UMB2
UMB3
TEMP
1TO AB10
2TO AB11
3TO AB12
4TO AB13
5FROM AC5
6FROM AC6
7FROM AC7
8TO AB14
8FROM AC8
FROM AE2 11
FROM AB9
9
AD
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 49 – Release 2.0
H3 H4
H5H6
H10H11H12H13 H15 H16
H20
H21
H22
H1 H2H23 C
32
META SYSTEM PROPERTY ALL RIGHT RESERVED ART. 1151-1/2/3
CODICE:
TITOLO:
DATA:
IL TECNICO PROGETTISTA:
IL TECNICO DISEGNATORE:
SCALA:
___________________________
___________________________
RIFERIM. X:
R
METASYSTEM
R
HANU1HANU2
HANU3HANU4
145 8
U5
C34
C35
C36
C37
L5
L6A
L7A
L8 L9
C1
C10
C11
C12
C13
C14
C17
C19
C2
C21C23
C24
C25
C26
C27 C28
C3
C4
C5
C6
C7
C8
C9
D10
D11
D12 D13D14
D4
D5
D7
DZ1
DZ2
1 458
U4
1 458
U3
19
210
EC1
1EC
2
L1
L2
L3 L4
PP1
PP10
PP2
PP3
PP4PP5
PP6
PP7PP8PP9
Q1
Q2AQ3A
R1
R10
R11
R12 R1
3
R14
R15
R16
R17
R18
R19
R2
R20
R21
R22
R23
R24
R25
R26
R27
R28
R29
R3
R30
R31
R32
R4
R40
R41
R42
R43
R46
R47
R48
R49
R5
R50
R51
R52
R53
R6R7
R8R9
1 3
RV1
1 3
RV2
1 3
RV3
1 3
RV4
1 3
RV5
1 458
U1
178
14U2
C29
C30
R44
R45
C33
C15
C16
R33
R34
C31C38
FER7E8
FER5E6
FER3E4
FER1E2
MET
A SY
STEM
META SYSTEM
4:3PER AVERE LA SERIGRAFIA ACCENDERE DOC_TEXT L17 !!
MOTTI
S3123 LC/A
S312
3 LS
/A
K3123A01 09/04/01
CONTROLLER MODULO RF VL1000/VL500 PLUS
SCORTICATI
EC1
EC2
REFTEMP
UMB1 UMB2
UMB3
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 50 – Release 2.0
RF CONTROL MOD. RF VL1000 PLUS ReS Revised: Tuesday, April 10, 2001 K3123A01.SCH Revision: ?
META SYSTEM SpA PROPERTY ALL RIGHTS RESERVED ART. 1151-1/2/3 IL TECNICO PROGETTISTA:MOTTI ENZO IL TECNICO DISEGNATORE:SCORTICATI STEFANO
Bill Of Materials October 9,2001 12:05:18
Page1
Comp.No. Stock No. Designation Manufacturer Designation
C1 C3315B 150P COG 0805 MURATA GRM40 COG 151 J50 C2 C3410F 1N X 0805 MURATA GRM40 X7R 102 J50 C3 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25 C4 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25 C5 C3315B 150P X 0805 MURATA GRM40 COG 151 J50 C6 C42101 10U 16V ELNA RV2-16V100M-D55R C7 C3510F 10N X 0805 MURATA GRM40 X7R 103 J50 C8 C42103 10U 35V D5 NIC NACE10M35V5X5.5TR1
3 C9 C3510F 10N X 0805 MURATA GRM40 X7R 103 J50 C10 C3510F 10N X 0805 MURATA GRM40 X7R 103 J50 C11 C3510F 10N X 0805 MURATA GRM40 X7R 103 J50 C12 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25 C13 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25 C14 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25 C15 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25 C16 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25 C17 C3510F 10N X 0805 MURATA GRM40 X7R 103 J50 C19 C3510F 10N X 0805 MURATA GRM40 X7R 103 J50 C21 C42103 10U 35V D5 NIC NACE10M35V5X5.5TR1
3 C23 C3410B 1N TRD 0805 MURATA GRM40 COG 102 J50 C24 C3410B 1N TRD 0805 MURATA GRM40 COG 102 J50 C25 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25 C26 C3510F 10N X 0805 MURATA GRM40 X7R 103 J50 C27 C3410B 1N COG 0805 MURATA GRM40 X7R 103 J50 C28 C3410B 1N TRD 0805 MURATA GRM40 X7R 103 J50 C29 C3410B 1N COG 0805 MURATA GRM40 X7R 103 J50 C30 C3410B 1N COG 0805 MURATA GRM40 X7R 103 J50 C31 C3410B 1N TRD 0805 MURATA GRM40 X7R 103 J50 C32 C01765 0U1 TRD 100V SIEMENS B37987 F1104 K100 C33 C3610F 0U1 X 0805 MURATA GRM40 X7R 104 J25
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 51 – Release 2.0
C34 C02160 1N TRD MURATA ERE22X5C1H102JD13L C35 C02160 1N TRD MURATA ERE22X5C1H102JD13L C36 C02160 1N TRD MURATA ERE22X5C1H102JD13L C37 C02160 1N TRD MURATA ERE22X5C1H102JD13L C38 C3410B 1N COG 0805 MURATA GRM40 COG 102 J50 D4 D05021 SM4004 PHILIPS S1G D5 D05006 BAV99 PHILIPS BAV99 D7 D05011 BAW56 PHILIPS BAW56 D10 D05006 BAV99 PHILIPS BAV99 D11 D05006 BAV99 PHILIPS BAV99 D12 D05002 BAV70 PHILIPS BAV70 D13 D05006 BAV99 PHILIPS BAV99 D14 D05011 BAW56 PHILIPS BAW56 DZ1 D00117 9V1 TRD 1W PHILIPS BZV85-C9V1 DZ2 D02152 BZX84-15V PHILIPS BZX84-C15V EC1 E05610 2X5PMAS90 TRD NL INDUSTRIES MFCA10W EC2 E04709 MAT4PMAS90 TRD AMP 1-350944-0 FER1 M01090 FERRITE-TOROID-T20-12 TRD AMIDON T20-12 FER2 M01090 FERRITE-TOROID-T20-12 TRD AMIDON T20-12 FER3 M01090 FERRITE-TOROID-T20-12 TRD AMIDON T20-12 FER4 M01090 FERRITE-TOROID-T20-12 TRD AMIDON T20-12 FER5 M01090 FERRITE-TOROID-T20-12 TRD AMIDON T20-12 FER6 M01090 FERRITE-TOROID-T20-12 TRD AMIDON T20-12 FER7 M01090 FERRITE-TOROID-T20-12 TRD AMIDON T20-12 FER8 M01090 FERRITE-TOROID-T20-12 TRD AMIDON T20-12 L1 M12150 15UH SIEMENS B82422-A1153-K100 L2 M12150 15UH SIEMENS B82422-A1153-K100 L3 M12150 15UH SIEMENS B82422-A1153-K100 L4 M12150 15UH SIEMENS B82422-A1153-K100 L5 M12150 15UH SIEMENS B82422-A1153-K100 L6A M00086 15UH TRD SIEMENS B78108-S1153-K L7A M00086 15UH TRD SIEMENS B78108-S1153-K L8 M12150 15UH SIEMENS B82422-A1153-K100 L9 M12150 15UH SIEMENS B82422-A1153-K100 Q1 T05003 BC807 PHILIPS BC807/25 Q2A T05012 MJD42 MOTOROLA MJD45H11-T4 Q3A T05012 MJD42 MOTOROLA MJD45H11-T4 R1 R54422 R34422 4K22 1% 0805 SIEMENS B54102A2 422F260 R2 R55100 R35100 10K 1% 0805 SIEMENS B54102A2 103F060 R3 R54680 6K8 1% 0805 SIEMENS B54102A2 682F060 R4 R55100 R35100 10K 1% 0805 SIEMENS B54102A2 103F060 R5 R24471 4K7 0805 SIEMENS B54102A1 472J60 R6 R25101 10K 0805 SIEMENS B54102A1 103J60 R7 R25101 10K 0805 SIEMENS B54102A1 103J60 R8 R27101 1M 0805 SIEMENS B54102A1 105J60 R9 R26101 100K 0805 SIEMENS B54102A1 104J60 R10 R24271 2K7 0805 SIEMENS B54102A1 272J60 R11 R24821 8K2 0805 SIEMENS B54102A1 822J60 R12 R24221 2K2 0805 SIEMENS B54102A1 222J60
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 52 – Release 2.0
R13 R23101 100 0805 SIEMENS B54102A1 101J60 R14 R27221 2M2 0805 SIEMENS B54102A1 225J60 R15 R22220 22 1206 SIEMENS B54103A1 220 J60 R16 R24100 1K 1206 SIEMENS B54103A1 102 J60 R17 R22100 10 1206 SIEMENS B54103A1 100 J60 R18 R25101 10K 0805 SIEMENS B54102A1 103J60 R19 R25101 10K 0805 SIEMENS B54102A1 103J60 R20 R25101 10K 0805 SIEMENS B54102A1 103J60 R21 R24471 4K7 0805 SIEMENS B54102A1 472J60 R22 R24471 4K7 0805 SIEMENS B54102A1 472J60 R23 R26331 330K 0805 SIEMENS B54102A1 334J60 R24 R24471 4K7 0805 SIEMENS B54102A1 472J60 R25 R24221 2K2 0805 SIEMENS B54102A1 222J60 R26 R26101 100K 0805 SIEMENS B54102A1 104J60 R27 R25101 10K 0805 SIEMENS B54102A1 103J60 R28 R25101 10K 0805 SIEMENS B54102A1 103J60 R29 R26471 470K 0805 SIEMENS B54102A1 474J60 R30 R23471 470 0805 SIEMENS B54102A1 471J60 R31 R25101 10K 0805 SIEMENS B54102A1 103J60 R32 R25100 10K 1206 SIEMENS B54103A1 103 J60 R33 R25151 15K 0805 SIEMENS B54102A1 153J60 R34 R25101 10K 0805 SIEMENS B54102A1 103J60 R40 R24121 1K2 0805 SIEMENS B54102A1 122J60 R41 R54130 1K3 1% 0805 SIEMENS B54102A2 132F060 R42 R54130 1K3 1% 0805 SIEMENS B54102A2 132F060 R43 R54470 R34470 4K7 1% 0805 SIEMENS B54102A2 472F060 R44 R54100 1K 1% 0805 SIEMENS B54102A2 102F060 R45 R54130 1K3 1% 0805 SIEMENS B54102A2 132F060 R46 R25221 22K 0805 SIEMENS B54102A1 223J60 R47 R25101 10K 0805 SIEMENS B54102A1 103J60 R48 R24101 1K 0805 SIEMENS B54102A1 102J60 R49 R54100 R34100 1K 1% 0805 SIEMENS B54102A2 102F060 R50 R54383 3K83 1% 0805 SIEMENS B54102A2 382F360 R51 R24151 1K5 0805 SIEMENS B54102A1 152J60 R52 R55100 10K 1% 0805 SIEMENS B54102A2 103F060 R53 R35124 12K4 1% 1206 SIEMENS B54103A2 123F460 RV1 R0518 10K TRD ORIZ BOURNS 3386P-1-103 RV2 R0520 22K TRD ORIZ BOURNS 3386P-1-223 RV3 R0520 22K TRD ORIZ BOURNS 3386P-1-223 RV4 R0518 10K TRD ORIZ BOURNS 3386P-1-103 RV5 R0518 10K TRD ORIZ BOURNS 3386P-1-103 U1 I01401 LM358 SAMSUNG KA358D U2 I01418 MC33079D MOTOROLA MC33079D U3 I01806 LM336 NATIONAL LM336M5 U4 I01806 LM336 NATIONAL LM336M5 U5 I01403 LM393 SAMSUNG KA393DTF
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
5X
3X
6X
6X
vfeed
prot3
K3113C01.SCH 00
ALIMENTATORE VL1000
META SYSTEM S.p.A
PROPERTY ALL RIGHTS RESERVED ART.1151 2/3/4IL TECNICO PROGETTISTA:INCERTI ERNESTOIL TECNICO DISEGNATORE:SCORTICATI STEFANO
C
1 1Monday, April 15, 2002
Title
Size Document Number Rev
Date: Sheet of
feed1drv2 drv1
Lin vin
voutdrv3 alc
st-byAC1
ref4
AC1
prot2AC2
prot3 prot1fctrl
vfeed
cs
FAN
FCTRL
ref3
ctrl
ref1
drv1
REF
drv2
FAN
drv3
prot1
alcprot2
REF
ref1vin
REF
iout cs st-by
ref4
velvel REF1
ctrl TP16ref1
TP16 TP17tmp ovld ilim
TP17
AC1
iouttmpovld
ilim
Nin
feed1
1
1
1
1
1
1
1
1
1
1
2
2 2 2 2 2 2 22
22 2
2
2
2
1
3
3 3
+15 +15
+15
+15
+22+22
+15
+15
+18
+15
+22
+15
+22
+15
+22
+15
+15A
+22
+15
-15
-15
-15
-15
-15+15
1
1
1
+15A
L215UH
R2010K2W
R312K2
R914K22
1%
R344K7
R951K
R6510K
R554K7
D36
SH2
C420U1
Q2
BC337
TP16
R5
10K
1%
C75470P
C341N
R15103W
D32
F4F-1A
C11
Q112SK2611
D241N4148
C300U1
R13
D5
L915UH
U5 UC385412345678 9
1011121314
1615
GNDPKLMTCAOUTISENSEMULTOUTIACVAOUTVRMS VREF
ENAVSENSE
RSETSSCT
GTDRVVCC
1
EC3MAT3PMASDIR
123
C471U
R771K1%
TP1
C14 1U
R1174K7
DZ5 7V5
L615UH
C921N100V
R30
22K
R89
Q12BC337
C360U1
C390U1
R11510K
F8F-1A
TP25
TP26
C5210N
R1124K7
EC22X8PMASDIR
1 23 45 67 89 1011 1213 1415 16
TP33
L1315UH
-
+U1A
MC330793
21
411
C651U50VX7R
C16 10N
R9812W R33
4K7
L1615UH
RK1LM335
L4120UH
C83
C61U
250VAC
PF2PORTAFUSE
C771NX7R
C682N2Y
R601K
L315UH
Q7
IGBT
R28390
Q3
BC337
C871U
R71100
D7
TP34
D18BYW98
+
-
U2D
MC33079
12
1314
R274K7
C191000U
R73
2K371%
R11010K
R54470
R783K831%
R9242K21%
D26
D31
C10
330U450V
TP30
EC7AMP4P90
4321
R47
330K
C460U1
C201U
C181U
R3610K
C8
TP19
C4547N
R93150K
R14
0.0822W
R5310K
U3TLP521
12 3
4
C9
PF1
C331N100V
F7F-1A
C401U
D35
SH4
C982N2 Y
Q1
IGBT
R1015K7W
C691U50VX7R
SH1
DZ927V1W
Q5
BC327
TP29
D38BYV32
23
1
C480U1
R6310
D1 800V-8A
Q10BC337
C2
R6847K1W
R2447K1W
R2121K1%
C64
10U
D27
D29
C8110N
R700
C491U
C791000U
C6710N
__|
T4TRASFVL1000
1
25
4
7
9
6
8
3
R3121K1%
R57
4K7
C531U
TP36
L1415UH
PP1
-
+U2A
MC330793
21
411
C891U50VX7R
C570U1
C630U1
R82121K
1%
R2910K
TP11
PF3PORTAFUSE
TP21
DZ1122V
D19BYW98
CW
RV22K2
ORIZ
TP28
C582N2
R991K1/2W
R251K1%
C512N2
EC8AMP4P90
4321
U6TLP521
12 3
4
R49316K 1%
R42220K
R322M2
R11810K
D30
DZ73V30W5
D111N4002
R10047K
R403K9
R810
Q8BC337
R11
D49
R3510K
D37BYV32
23
1
R644K7
C591N100VX7R
C620U1
RL1RELE-12V-16A-1SC
1 2
34
5
+
-
U2CMC33079
10
98
P2800V-8A
R852K611%
R1610K2W
C7210NX7R
C41U
DZ6TL431
R103337W
C510U
TP35
R51100K
C440U1X7R
C4147U
C76100P
DZ1016V
TP10
R9622
SH3
D28
C251U
C541U
R1021K
R172702W
C1
D10 BYV322
31
Q17MS1307
C271U
R8610K1%
R5810K
R1210
C901U50VX7R
R761K2
R41100
R4121K1%
TP17
L1115UH
D131N4007
C5010N
R881K1%
D17 BYV322
31
C971U50V
+
-
U1D
MC33079
12
1314
23
41
56
78
U7UC3844
C950U1
C6010N
R710 TP6
Q9
BC327
R45
470K
C821U50VX7R
C741NX7R
C551N
R2110K2W
R67100K1%
PF4PORTAFUSE
D8
Q16MOS-POT
TP24
TP3
+
-
U1BMC33079
5
67
C131U
250VAC
TP4
TP7 TP5
D251N4148
R5622K
C992N2 Y
TP20
D4
D34
L1015UH
D23
C5647U
R9
C8010U
C222N2Y
C6110N
R1131K54
1%R74
4K751%
R1011K
C861U
DZ1
16V
C3710U
D9BYV32
23
1
D33
*
L16MHVL1000
T1TRASF-PILOT-VL1000
C781000U
CW
RV44K7
R5218K21%
C911U50VX7R
R830
R383K9
Q4
IGBT600V-30A
C71U250VAC
R691K 1%
D16BYW98
R50
TP2
R225605W
D6
R48
R182702W
1
EC4MAT3PMASDIR
123
R593.3
R1910K1%
L815UH
EC10AMP6PMASDIRTRD
654321
R615K7W
C310N
R11610
TP27
TP18
+
-U1C
MC33079
10
98
C242N2Y
R11110K
23
45
67
8 910
1112
1314
15161
U4
SG3525
D14BYV26E
C2910N
TP9
T3TRASF-USCITA-VL1000
CW
RV34K7
ORIZ
F1 EF-12A
R46
470K
L1515UH
D39
D22 BYV322
31
TP8
R1091K1/2W
R1121K1%
EC9AMP2PDIR
21
R44680K
R792K2
C12
1
EC5MAT4PMASDIR
1234
C851U
C7047U35V
R9747K
L1215UH
R721K 1%
C310U1
L550UH
C66100P
R61330K
C261U
R11410K1%
C151000U
C2147U
450V
C35100P
C281U
R434K7
+
-
U2B
MC330795
67
C731NX7R
DZ83V3
C71100U35V
R811K
R871M
R2610K
C961000U35V
D121N4002
D15BYV26E
P1800V-8A
C930U1
C432N2
R66 10K
R379K091%
Q6
BC327
TP32
C8810N
C32 1U
R901K1/2W
TP31
C3847U
R6210K1%
D2
CW
RV14K7
C84
R945K62
1%
R391K1%
C171000U
*T2
VL1000TRASF-SENS-CORRENTE
L7120UH
C232N2Y
R75100K1%
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 54 – Release 2.0
T2
T1
EC5
R103
CO
MNA NC
RL1
EC4
C83
C84
META SYSTEM PROPERTY ALL RIGHT RESERVED ART. 1151-1/2/3
CODICE:
TITOLO:
DATA:
IL TECNICO PROGETTISTA:
IL TECNICO DISEGNATORE:
SCALA:
___________________________
___________________________
RIFERIM. X:
R
METASYSTEM
R
D11D1
2
R15
C21
R16
R20
R21
C22
C68
R24
R68
C69
C70
D13
R90
+E
-
C71
D14
1E4
U7
C72
C73
C74 C75
C76
C77
R98
D15
T4
D16
D18
+E
-
C78
+E
-
C79
C82
C89
C90
C91
R99
R109
1
EC9
1E
EC10
EC3
PP1
+E
-
C96
C97
D19
1E
EC8
1E
EC7
C98
C99
+-
C1+
-
C10
+-
C11
+-
C12
C13
C14
+
-
C15
C16
+
-
C17
C18
+
-
C19
C2
C20
C23
C24
C25
C26
C27
C28
C29
C3
C30
C31
C32
C33
C34 C35
C36
C37
C38
C39
C4
C40
C41
C42
C43C44
C45
C46
C47
C48
C49
C5
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C6
C60C61
C62
C63
C64 C65
C66
C67
C7
+-
C8
+-
C9
D1
D10
D17
D2
D22
D23
D24D25
D26
D27
D28
D29
D30
D31
D32
D33D34
D35
D36
D4
D5
D6
D7
D8
D9
DZ1
DZ5
DZ6
DZ7
DZ8
1E2
1516
EC2
112
1324
L1
L10 L11L12 L13
L14
L2
L3
L4
L5
L6
L7
L8 L9
P1Q1
Q10
Q2
Q3
Q4
Q5
Q6
Q7
Q8
Q9
R1
R10
R11
R12
R13
R14
R17
R18
R19
R2
R22R2
5
R26
R27
R28
R29
R3
R30
R31
R32
R33
R34
R35
R36
R37
R38
R39
R4
R40
R41
R42
R43
R44
R45
R46 R47
R48
R49
R5
R50
R51
R52
R53
R54
R55
R56
R57
R58
R59
R6
R60
R61
R62
R63
R64
R65
R66
R67
R69
R7
R70R71R72
R73
R74
R75
R76
R77
R78
R79
R8
R81
R82
R83
R85
R86
R87
R88
R9
1 3
RV1
1 3
RV2
1 3
RV3
1 3
RV4
SH1
SH2
SH3
SH4
1O12
1324
T3
17
U1
17
U2
1
U3
18
U4
18
U5
1
U6
P2
D37D38
R89
Q16DZ10
D49
R100
R101
R102
C80
L15
C81
RK1
R97
PF2
C85
C86
C87
L16
C88
PF1
R91
R92
R93
R94
R95
R96
DZ9
Q11
Q17
R110
R111
R112
Q12
C92
D39
C93
R113
R114
R115
C95
DZ11
R116
R117
PF3
PF4
R118
CAVALCABUE
INCERTI
7:8
S3113C01 09-01-01
SCHEDA ALIMENTATORE VL1000 PLUS
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 55 – Release 2.0
ALIMENTATORE VL1000 Revised: Wednesday, April 04, 2001 K3113C01.SCH Revision: 00
META SYSTEM S.p.A
PROPERTY ALL RIGHTS RESERVED ART.1151 2/3/4 IL TECNICO PROGETTISTA:INCERTI ERNESTO IL TECNICO DISEGNATORE:SCORTICATI STEFANO
STAMPATO C.S. S3113B
Bill Of Materials October 9,2001 12:07:08
Page1
Comp. No. Stock No. Designation Manufacturer Designation
C1 C2333Y 330U TRD 450V DAEWOO FHS2W331MLSAS2 C2 C01553 1U TRD 250VAC MKP ICEL MAB A254 100 KHS C3 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C4 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C5 C2210J 10U TRD 50V ELNA RE2-063V100M C6 C00188 1U TRD 250VAC MKP-X OKAJA CO-RE105 C7 C00188 1U TRD 250VAC MKP-X OKAJA CO-RE105 C8 C2333Y 330U TRD 450V DAEWOO FHS2W331MLSAS2 C9 C2333Y 330U TRD 450V DAEWOO FHS2W331MLSAS2 C10 C2333Y 330U TRD 450V DAEWOO FHS2W331MLSAS2 C11 C2333Y 330U TRD 450V DAEWOO FHS2W331MLSAS2 C12 C2333Y 330U TRD 450V DAEWOO FHS2W331MLSAS2 C13 C01553 1U TRD 250VAC MKP ICEL MAB A254 100 KHS C14 C01788 1U TRD 50V MURATA RPER71H105K3M1 C15 C2410M 1000U TRD 63V ELNA RE3-063V102M C16 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C17 C2410M 1000U TRD 63V ELNA RE3-063V102M C18 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C19 C2410M 1000U TRD 63V ELNA RE3-063V102M C20 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C21 C2247Y 47U TRD 450V DAEWOO FHS47450 22X25 C22 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A C23 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A C24 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A C25 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C26 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C27 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C28 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C29 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C30 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 56 – Release 2.0
C31 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C32 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C33 C01717 1N TRD 100V X7R SIEMENS B37981F1102K51 C34 C01717 1N TRD 100V X7R SIEMENS B37981F1102K51 C35 C1310D 100P TRD 100V X7R PHILIPS 2222642 10101 C36 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C37 C2210J 10U TRD 50V ELNA RE2-063V100M C38 C2247J 47U TRD 50V PANASONIC ECA1JM470BJ C39 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C40 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C41 C2247J 47U TRD 50V PANASONIC ECA1JM470BJ C42 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C43 C00919 2N2 TRD 63V MKT SIEMENS B32529C1222K C44 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C45 C1547W 47N TRD Y5V MURATA DD306-63F473Z50 C46 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C47 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C48 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C49 C2110J 1U TRD 50V ELNA RE2-100V010M C50 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C51 C00919 2N2 TRD 63V MKT SIEMENS B32529C1222K C52 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C53 C2110J 1U TRD 50V ELNA RE2-100V010M C54 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C55 C01717 1N TRD 100V X7R SIEMENS B37981F1102K51 C56 C2247J 47U TRD 50V PANASONIC ECA1JM470BJ C57 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C58 C01724 2N2 TRD 50V X7R MURATA RPER71H222K3M1 C59 C01717 1N TRD 100V X7R SIEMENS B37981F1102K51 C60 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C61 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C62 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C63 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C64 C2210J 10U TRD 50V ELNA RE2-063V100M C65 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C66 C1310D 100P TRD 100V PHILIPS 2222642 10101 C67 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C68 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A C69 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C70 C2247F 47U TRD 35V DAEWOO RS35V47UF C71 C2310H 100U TRD 35V ELNA RE2035V101 C72 C01740 10N TRD 100V X7R MURATA RPE132-901X7R103K100MC73 C01717 1N TRD 100V X7R SIEMENS B37981F1102K51 C74 C01717 1N TRD 100V X7R SIEMENS B37981F1102K51 C75 C1347N 470P TRD 63V MURATA RD876-2N750 471J C76 C1310D 100P TRD 100V PHILIPS 2222642 10101 C77 C01717 1N TRD 100V X7R SIEMENS B37981F1102K51 C78 C2410F 1000U TRD 35V DAEWOO RM35V1000UF C79 C2410F 1000U TRD 35V DAEWOO RM35V1000UF
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 57 – Release 2.0
C80 C2210J 10U TRD 50V ELNA RE2-063V100M C81 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C82 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C83 C01538 0U1 TRD 250VAC MKP-X SIEMENS B81121CB125 C84 C01538 0U1 TRD 250VAC MKP-X SIEMENS B81121CB125 C85 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C86 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C87 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C88 C1510W 10N TRD Y5V PHILIPS 2222629 19103 C89 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C90 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C91 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C92 C01717 1N TRD 100V X7R SIEMENS B37981F1102K51 C93 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C95 C01764 0U1 TRD 63V X7R SIEMENS B37987F5104-K51 C96 C2410F 1000U TRD 35V DAEWOO RM35V1000UF C97 C01788 1U TRD 50V X7R MURATA RPER71H105K3M1 C98 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A C99 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A D1 D00724 800V-8A TRD VELOCE PHILIPS BYR29F-800 D2 D00724 800V-8A TRD VELOCE PHILIPS BYR29F-800 D4 D00724 800V-8A TRD VELOCE PHILIPS BYR29F-800 D5 D00504 1N4148 TRD PHILIPS 1N4148 D6 D00504 1N4148 TRD PHILIPS 1N4148 D7 D00504 1N4148 TRD PHILIPS 1N4148 D8 D00504 1N4148 TRD PHILIPS 1N4148 D9 D00723 BYV32 TRD PHILIPS BYV32F-200/B D10 D00723 BYV32 TRD PHILIPS BYV32F-200/B D11 D00511 1N4002 TRD MIC 1N4002 D12 D00511 1N4002 TRD MIC 1N4002 D13 D00516 1N4007 TRD MIC 1N4007 D14 D00719 BYV26E TRD PHILIPS BYV26E/A52R D15 D00719 BYV26E TRD PHILIPS BYV26E/A52R D16 D00700 BYW98 TRD ST BYW98-200 D17 D00723 BYV32 TRD PHILIPS BYV32F-200/B D18 D00700 BYW98 TRD ST BYW98-200 D19 D00700 BYW98 TRD ST BYW98-200 D22 D00723 BYV32 TRD PHILIPS BYV32F-200/B D23 D00504 1N4148 TRD PHILIPS 1N4148 D24 D00504 1N4148 TRD PHILIPS 1N4148 D25 D00504 1N4148 TRD PHILIPS 1N4148 D26 D00504 1N4148 TRD PHILIPS 1N4148 D27 D00504 1N4148 TRD PHILIPS 1N4148 D28 D00504 1N4148 TRD PHILIPS 1N4148 D29 D00504 1N4148 TRD PHILIPS 1N4148 D30 D00504 1N4148 TRD PHILIPS 1N4148 D31 D00504 1N4148 TRD PHILIPS 1N4148 D32 D00504 1N4148 TRD PHILIPS 1N4148 D33 D00504 1N4148 TRD PHILIPS 1N4148
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 58 – Release 2.0
D34 D00504 1N4148 TRD PHILIPS 1N4148 D35 D00504 1N4148 TRD PHILIPS 1N4148 D36 D00504 1N4148 TRD PHILIPS 1N4148 D37 D00723 BYV32 TRD PHILIPS BYV32F-200/B D38 D00723 BYV32 TRD PHILIPS BYV32F-200/B D39 D00504 1N4148 TRD PHILIPS 1N4148 D49 D00504 1N4148 TRD PHILIPS 1N4148 DZ1 D00147 16V TRD 1W PHILIPS BZX85C16 DZ5 D00107 7V5 TRD 1W PHILIPS BZX85C7V5 DZ6 I00320 TL431 TRD ST TL431ACZ DZ7 D00060 3V3 TRD 0W5 PHILIPS BZX79C3V3 DZ8 D00062 3V3 TRD 1W PHILIPS BZX85C3V3 DZ9 D00172 27V TRD 1W PHILIPS BZX85C27 DZ10 D00147 16V TRD 1W PHILIPS BZX85C16 DZ11 D00162 22V TRD 1W PHILIPS BZX85C22 EC2 E05603 2X8PMASDIR TRD NL INDUSTRIES MFCB16Y EC3 E04704 MAT3PMASDIR TRD AMP 0.0350429-1 EC4 E04704 MAT3PMASDIR TRD AMP 0.0350429-1 EC5 E04708 MAT4PMASDIR TRD AMP 0-0350430-1 EC7 E04328 AMP4P90 TRD AMP 0-0280378-1 EC8 E04328 AMP4P90 TRD AMP 0-0280378-1 EC9 E04320 AMP2PDIR TRD AMP 0-0280370-1 EC10 E04340 AMP6PMASDIR TRD AMP O-O280372-2 F1 V0763E EF-12A TRD 5X20 SABBIA FUSIT 520HF12 F4 V0741A F-1A TRD 5X20 OMEGA FUSIBILI CF520210 F7 V0741A F-1A TRD 5X20 OMEGA FUSIBILI CF520210 F8 V0741A F-1A TRD 5X20 OMEGA FUSIBILI CF520210 L1 M00179 6MH TRD VL1000 METASYSTEM M00179 L2 M00086 15UH TRD SIEMENS B78108S1153K L3 M00086 15UH TRD SIEMENS B78108S1153K L4 XF7L25 120UH TRD 30A METASYSTEM XF7L25 L5 XF7L26 50UH TRD 60A METASYSTEM XF7L26 L6 M00086 15UH TRD SIEMENS B78108S1153K L7 XF7L25 120UH TRD 30A METASYSTEM XF7L25 L8 M00086 15UH TRD SIEMENS B78108S1153K L9 M00086 15UH TRD SIEMENS B78108S1153K L10 M00086 15UH TRD SIEMENS B78108S1153K L11 M00086 15UH TRD SIEMENS B78108S1153K L12 M00086 15UH TRD SIEMENS B78108S1153K L13 M00086 15UH TRD SIEMENS B78108S1153K L14 M00086 15UH TRD SIEMENS B78108S1153K L15 M00086 15UH TRD SIEMENS B78108S1153K L16 M00086 15UH TRD SIEMENS B78108S1153K P1 D0098H 800V-8A TRD PONTE GENERAL SEMIC. KBU8K P2 D0098H 800V-8A TRD PONTE GENERAL SEMIC. KBU8K PF1 V0000A PORTAFUSE TRD OMEGA FUSIBILI C1010 PF2 V0000A PORTAFUSE TRD OMEGA FUSIBILI C1010 PF3 V0000A PORTAFUSE TRD OMEGA FUSIBILI C1010 PF4 V0000A PORTAFUSE TRD OMEGA FUSIBILI C1010
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 59 – Release 2.0
Q1 T01144 IGBT TRD 600V-30A HARRIS HGTG30N60B3D Q2 T00550 BC337 TRD PHILIPS BC337-25 Q3 T00550 BC337 TRD PHILIPS BC337-25 Q4 T01144 IGBT TRD 600V-30A HARRIS HGTG30N60B3D Q5 T00540 BC327 TRD PHILIPS BC327-25 Q6 T00540 BC327 TRD PHILIPS BC327-25 Q7 T01144 IGBT TRD 600V-30A HARRIS HGTG30N60B3D Q8 T00550 BC337 TRD PHILIPS BC337-25 Q9 T00540 BC327 TRD PHILIPS BC327-25 Q10 T00550 BC337 TRD PHILIPS BC337-25 Q11 T01136 2SK2611 TRD TOSHIBA 2SK2611 Q12 T00550 BC337 TRD PHILIPS BC337-25 Q16 T01119 MOS-POT TRD TO220 SAMSUNG IRFZ14A Q17 T02000 MS1307 TRD IR 94-2293 R1 R01526 121K TRD 1% ROY MF25 121KOHM F R2 R01526 121K TRD 1% ROY MF25 121KOHM F R3 R01526 121K TRD 1% ROY MF25 121KOHM F R4 R01526 121K TRD 1% ROY MF25 121KOHM F R5 R01318 10K TRD 1% ROY MF25 10KOHM F R6 R03665 15K TRD FILO 7W ATE 7CS0225 R7 R00121 10 TRD ROY CR25PS10OHM J R8 R00121 10 TRD ROY CR25PS10OHM J R9 R02994 0.082 TRD 2W ATE 2CS0664 R10 R03665 15K TRD FILO 7W ATE 7CS0225 R11 R02994 0.082 TRD 2W ATE 2CS0664 R12 R00121 10 TRD ROY CR25PS10OHM J R13 R02994 0.082 TRD 2W ATE 2CS0664 R14 R02994 0.082 TRD 2W ATE 2CS0664 R15 R03209 10 TRD FILO 3W ATE 3CSS0001 R16 R04289 10K TRD 2W PIHER EO-02-10KOHM R17 R04175 270 TRD 2W PIHER EO-02-270OHM R18 R04175 270 TRD 2W PIHER EO-02-270OHM R19 R01318 10K TRD 1% ROY MF25 10KOHM F R20 R04289 10K TRD 2W PIHER EO-02-10KOHM R21 R04289 10K TRD 2W PIHER EO-02-10KOHM R22 R03462 560 TRD FILO 5W FAREM RFA5-560J5W R24 R04336 47K TRD 1W PIHER EO-01-47KOHM R25 R01126 1K TRD 1% ROY MF25 1KOHM F R26 R00481 10K TRD ROY CR25PS10KOHM J R27 R00441 4K7 TRD ROY CR25PS4.7KOHM J R28 R00311 390 TRD ROY CR25PS390 OHM J R29 R00481 10K TRD ROY CR25PS10KOHM J R30 R00521 22K TRD ROY CR25PS22KOHM J R31 R00401 2K2 TRD ROY CR25PS2.2KOHM J R32 R00761 2M2 TRD ROY CR25PS2.2MOHM J R33 R00441 4K7 TRD ROY CR25PS4.7KOHM J R34 R00441 4K7 TRD ROY CR25PS4.7KOHM J R35 R00481 10K TRD ROY CR25PS10KOHM J R36 R00481 10K TRD ROY CR25PS10KOHM J
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 60 – Release 2.0
R37 R01310 9K09 TRD 1% ROY MF25 9.09KOHM R38 R00431 3K9 TRD ROY CR25PS3.9KOHM J R39 R01126 1K TRD 1% ROY MF25 1KOHM F R40 R00431 3K9 TRD ROY CR25PS3.9KOHM J R41 R00241 100 TRD ROY CR25PS100 OHM J R42 R00641 220K TRD ROY CR25PS220KOHM J R43 R00441 4K7 TRD ROY CR25PS4.7KOHM J R44 R00701 680K TRD ROY CR25PS680KOHM J R45 R00681 470K TRD ROY CR25PS470KOHM J R46 R00681 470K TRD ROY CR25PS470KOHM J R47 R00661 330K TRD ROY CR25PS330KOHM J R48 R01606 316K TRD 1% ROY MF25 316KOHM F R49 R01606 316K TRD 1% ROY MF25 316KOHM F R50 R01606 316K TRD 1% ROY MF25 316KOHM F R51 R00601 100K TRD ROY CR25PS100KOHM J R52 R01368 18K2 TRD 1% ROY MF25 18.2KOHM F R53 R00481 10K TRD ROY CR25PS10KOHM J R54 R00321 470 TRD ROY CR25PS470 OHM J R55 R00441 4K7 TRD ROY CR25PS4.7KOHM J R56 R00521 22K TRD ROY CR25PS22KOHM J R57 R00441 4K7 TRD ROY CR25PS4.7KOHM J R58 R00481 10K TRD ROY CR25PS10KOHM J R59 R00061 3.03 TRD ROY CR25PS3.3 OHM J R60 R00361 1K TRD ROY CR25PS1KOHM J R61 R00661 330K TRD ROY CR25PS330KOHM J R62 R01318 10K TRD 1% ROY MF25 10KOHM F R63 R00121 10 TRD ROY CR25PS10OHM J R64 R00441 4K7 TRD ROY CR25PS4.7KOHM J R65 R00481 10K TRD ROY CR25PS10KOHM J R66 R00481 10K TRD ROY CR25PS10KOHM J R67 R01510 100K TRD 1% ROY MF25 100KOHM F R68 R04336 47K TRD 1W PIHER EO-01-47KOHM R69 R01126 1K TRD 1% ROY MF25 1KOHM F R70 R09000 0 TRD SUN ELECTRONIC RC1000 R71 R00241 100 TRD ROY CR25PS100 OHM J R72 R01126 1K TRD 1% ROY MF25 1KOHM F R73 R01198 2K37 TRD 1% ROY MF25 2.37KOHM F R74 R01256 4K75 TRD 1% ROY MF25 4.75KOHM F R75 R01510 100K TRD 1% ROY MF25 100KOHM F R76 R00371 1K2 TRD ROY CR25PS1.2KOHM J R77 R01126 1K TRD 1% ROY MF25 1KOHM F R78 R01238 3K83 TRD 1% ROY MF25 3.83KOHM F R79 R00401 2K2 TRD ROY CR25PS2.2KOHM J R81 R00361 1K TRD ROY CR25PS1KOHM J R82 R01526 121K TRD 1% ROY MF25 121KOHM F R83 R09000 0 TRD SUN ELECTRONIC RC1000 R85 R01206 2K61 TRD 1% ROY MF25 2.61KOHM F R86 R01318 10K TRD 1% ROY MF25 10KOHM F R87 R00721 1M TRD ROY CR25PS1MOHM J
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 61 – Release 2.0
R88 R01126 1K TRD 1% ROY MF25 1KOHM F R89 R02994 0.082 TRD 2W ATE 2CS0664 R90 R00362 1K TRD 1/2W ROY CR50PS 1KOHM J R91 R01246 4K22 TRD 1% ROY MF25 4.22KOHM F R92 R01438 42K2 TRD 1% ROY MF25 42.2KOHM F R93 R00621 150K TRD ROY CR25PS150KOHM J R94 R01270 5K62 TRD 1% ROY MF25 5.62KOHM F R95 R00361 1K TRD ROY CR25PS1KOHM J R96 R00161 22 TRD ROY CR25PS 22OHM J R97 R00561 47K TRD ROY CR25PS47KOHM J R98 R04001 1 TRD 2W PIHER EO-02 1 OHM R99 R00362 1K TRD 1/2W ROY CR50PS 1KOHM J R100 R00561 47K TRD ROY CR25PS47KOHM J R101 R00361 1K TRD ROY CR25PS1KOHM J R102 R00361 1K TRD ROY CR25PS1KOHM J R103 R03283 33 TRD FILO 7W ATE 7CS33R-5% R109 R00362 1K TRD 1/2W ROY CR50PS 1KOHM J R110 R00481 10K TRD ROY CR25PS10KOHM J R111 R00481 10K TRD ROY CR25PS10KOHM J R112 R00441 4K7 TRD ROY CR25PS4.7KOHM J R113 R01162 1K54 TRD 1% ROY MF25 1.54KOHM F R114 R01318 10K TRD 1% ROY MF25 10KOHM F R115 R00481 10K TRD ROY CR25PS10KOHM J R116 R00121 10 TRD ROY CR25PS10OHM J R117 R00441 4K7 TRD ROY CR25PS4.7KOHM J R118 R00481 10K TRD ROY CR25PS10KOHM J RK1 I00318 LM335 TRD NATIONAL LM335AZ RL1 E02004 RELE-12V-16A-1SC TRD SCHRACK RP71001 RV1 R0516 4K7 TRD ORIZ BOURNS 3386P-1-502 RV2 R0514 2K2 TRD ORIZ BOURNS 3386P-1-202 RV3 R0516 4K7 TRD ORIZ BOURNS 3386P-1-502 RV4 R0516 4K7 TRD ORIZ BOURNS 3386P-1-502 SH1 R09007 SHUNT TRD D2-35MM-H8 METASYSTEM R09007 SH2 R09007 SHUNT TRD D2-35MM-H8 METASYSTEM R09007 SH3 R09007 SHUNT TRD D2-35MM-H8 METASYSTEM R09007 SH4 R09007 SHUNT TRD D2-35MM-H8 METASYSTEM R09007 T1 M02197 TRASF-PILOT-VL1000 TRD METASYSTEM M02197 T2 XF7L60 TRASF-SENS-CORRENTE TRD VL1000 METASYSTEM XF7L60 T3 M02196 TRASF-USCITA-VL1000 TRD METASYSTEM M02196 T4 M02198 TRASFVL1000 TRD METASYSTEM M02198 U1 I00315 MC33079 TRD MOTOROLA MC33079P U2 I00315 MC33079 TRD MOTOROLA MC33079P U3 A03012 TLP521 TRD SIEMENS SFH615A-3 U4 I00422 SG3525 TRD ST SG3525AN U5 I00420 UC3854 TRD UNITRODE UC3854N U6 A03012 TLP521 TRD SIEMENS SFH615A-3 U7 I00423 UC3844 TRD ST UC3844N
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 62 – Release 2.0
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
S3114D.SCH
FILTRO RETE VL1000 PLUS
META SYSTEM S.p.A
PROPERTY ALL RIGHTS RESERVED ART1151-1/2/3
IL TECNICO PROGETTISTA:INCERTI ERNESTO
IL TECNICO DISEGNATORE:SCORTICATI STEFANO
A
1 1Thursday, February 22, 2001
Title
Size Document Number Rev
Date: Sheet of
C4
2N2
Y
L3
2M7H
16A
EC4
PRESA-10A-250V
CS-90
PF2
L2
2M7H
16A
L1
150UH
VR3
275V40J
PF1
PORTAFUSE
D10-CS-20A
R1
100K
TRD
F-2A
R3
100K
TRD
R2
100K
TRD
VR6
275V40J
VR2
275V40J
VR5
275V40J
VR4
275V40J
C1
1U
250VAC
C3
2N2
Y
C2
1U
250VAC
EC1
MAT6PMAS90
1
2
3
4
5
6
1
PF3
PORTAFUSE
C5C6
2N2
250VAC
Y
F-16A
N
L
LINE
INPUT
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 63 – Release 2.0
EC2
H2H1
H3
H4
H5
L1
H6
H7
META SYSTEM PROPERTY ALL RIGHT RESERVED ART. 1151-1/2/3
CODICE:
TITOLO:
DATA:
IL TECNICO PROGETTISTA:
IL TECNICO DISEGNATORE:
SCALA:
___________________________
___________________________
RIFERIM. X:
R
METASYSTEM
R
R1R2R31E
EC3
C1
C2
C3
C4
N
E
L
EC4
L2
PF1
PF3
VR2
VR3
VR4
VR5
VR6
L3
C5
C6
CAVALCABUE
INCERTIFILTRO VL1000 PLUS
127:89
S3114D 22-11-00
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 64 – Release 2.0
FILTRO RETE VL1000 PLUS Revised: Thursday, February 22, 2001 S3114D.SCH Revision: ?
META SYSTEM S.p.A PROPERTY ALL RIGHTS RESERVED ART1151-1/2/3
IL TECNICO PROGETTISTA:INCERTI ERNESTO IL TECNICO DISEGNATORE:SCORTICATI STEFANO
Bill Of Materials October 9,2001 12:13:04
Page1
Comp. No. Stock No. Designation Manufacturer Designation
C1 C00188 1U TRD 250VAC MKP-X OKAYA CO-RE105 C2 C00188 1U TRD 250VAC MKP-X OKAYA CO-RE105 C3 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A C4 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A C5 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A C6 C00187 2N2 TRD 250VAC Y MURATA DE2E3KY222MN2A EC1 E04718 MAT6PMAS90 TRD AMP 0-640583-1 EC4 E04815 PRESA-10A-250V TRD CS-90 K&B 43R65.1111 F1 V0765F F-16A TRD 10X38 GI OMEGA FUSIBILI GI 138-316 F2 V0747A F-2A TRD 5X20 OMEGA FUSIBILI CF 520-220 L1 M00166 150UH TRD 8A TISCI 1X150 UH L2 M00174 2M7H TRD 16A TISCI 2X2.5 MH L3 M00174 2M7H TRD 16A TISCI 2X2.5 MH PF1 V0000 PORTAFUSE TRD D10-CS-20A BUSS 1A-3400-09 PF2 V0000 PORTAFUSE TRD D10-CS-20A BUSS 1A-3400-09 PF3 V0000A PORTAFUSE TRD OMEGA FUSIBILI C1010 R1 R00601 100K TRD ROY CR25PS 100KOHM J R2 R00601 100K TRD ROY CR25PS 100KOHM J R3 R00601 100K TRD ROY CR25PS 100KOHM J VR2 R06150 275V40J TRD SIEMENS SIOVS20K275 VR3 R06150 275V40J TRD SIEMENS SIOVS20K275 VR4 R06150 275V40J TRD SIEMENS SIOVS20K275 VR5 R06150 275V40J TRD SIEMENS SIOVS20K275 VR6 R06150 275V40J TRD SIEMENS SIOVS20K275
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 65 – Release 2.0
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
S3115D01.SCH
CONTROLLER VL1000 PLUS
META SYSTEM S.P.A.
Property all rights reserved art.1151-1/2/3
Resp.Tecnico: Allegri
Disegnatore: Scorticati
D
1 1Thursday, March 01, 2001
Title
Size Document Number Rev
Date: Sheet of
R45
1M
Q2BC817
C63
1N
COG
R96
47K
C601N
COG
L9
15UH
RV2
10KCW
C3910U
50V
RV3
10K
CW
C29
15P
U1D
LM324
12
13
14-
+
DZ1
BZX84-6V8
2
3
1
R94
470
R42
330K
R84
47K
R72
15K
C31N
COG
C42
1N
COG
U3A
LM324
3
2
1
411
-
+
R11
100K
C55
0U1
X
C75
10N
X
R8
C77
10N
X
R110470K
R99
10K
C68
10N
X
U3C
LM324
10
9
8-
+
R80
100K
Q5
IRLML2803
C86
10N
X
C52
0U1
X
C24
1N
COG
L7
15UH
TRD
RL2
RELE-12V-1A-2SC
2 1
6
7
5
8
4
3
D6
BAV70
2
3
1
R59
1K
1206
R24
10K
D10
BAV99
2
3
1
R61
10K
C44
0U1
X
Q4
BC817
C16
0U1
X
R116
470
1206
RV7
10KORIZ
CW
R5510K
1%
R95
470
R100
10K
R119
470
1206
EC13
2
1
R68
47K
R123
680
1206
R34
100K
L11
15UH
TRD
R2
22K
R113
10K
R124
680
1206
R13
390
1206
U12
DS75176B
RO1
RE2
DE3
DI4
GND5
DO/RI6
DO/DI7
VCC8
D12
BAW56
2
3
1
U7
Z
L12
15UH
TRD
R43
390
1206
R48
1K5
C560U1
X
R114
10K
D13
BAW56
2
3
1
R58
10K
R125
680
1206
JP2
HE-13/14-2P
1
2
R3110K
Q7
BC807
X1
16MHZ
U6
ST93C86
CS1
SK2
DI3
DO4
GND5
ORG6
N.C7
VCC8
R126
10K
R10
C21
0U1 X
R64
470K
C41
0U1
XR127
2K2
R29100K
C4
100U
TRD
25V
Q1
BC817
Q8
BC817
L17
15UH
R87
5K6
1%
C18
1N
COG
R111
10K
R128
1K
C5
0U1
X
R50
2K2
C30
0U1
X
U9
DS14C232
C1+1
V+2
C1-3
C2+4
C2-5
V-6
DO27
RI28
RO29
DI210
DI111
RO112
RI113
DO114
GND15
VCC16
U11ALM358
3
2
1
48
-
+
R121
68
TRD
D11
BAV99
2
3
1
R90
15K
D8SM4004
C76
10N
X
U4
L4949
VS1
SI2
VZ3
CT4
GND5
RES6
SO7
VO8
C19
1N
COG
R57
6K8
D7
BAW56
2
3
1
RL1
RELE-12V-1A-2SC
2 1
6
7
5
8
4
3
R17
10K
R62
470
C4310U
50V
6X6
JP7
1
2
C47
0U1
X
R98
4K7
C78
10N
X
L15
15UH
Q6
BC817
D3
BAV99
2
3
1
C34
10U
50V
6X6
C3510U
50V6X6
U2B
LM324
5
6
7-
+
C3610U
50V
6X6
R81
47K
C49
1N
X
U13
74HC4066
1Y1
1Z2
2Y4
2Z3
3Y8
3Z9
4Y11
4Z10
4E12
3E6
2E5
1E13
VCC14
GND7
C72
10N
X
C85
10N
X
R92
470
EC9
DB9-FEM-90
5 9 4 8 3 7 2 6 1
L13
15UH
TRD
D5
BAV99
2
3
1
R46
10K
EC2
2X5PMASDIR
1 2
3 4
5 6
7 8
9 10
R65
2K2
R88
18K
1%
U5
7805
I2
G3
O1
RV6
10K
CW
R67
10K
Q3
BC817
EC7
DB15-FEM-90
8
15
7
14
6
13
5
12
4
11
3
10
2
9
1
C74
10N
X
PIC17C756A
RC7
61RC
662
RC5
63RC
464
RC3
65RC
266
RC1
67VS
S68
NC1
VDD
2RC
03
RD7
4RD
65
RD5
6RD
47
RD3
8RD
29
RD110
RD011
RE012
RE113
RE214
RE315
MCLR16
TEST17
NC18
VSS19
VDD20
RF721
RF622
RF523
RF424
RF325
RF226
RF1
27
RF0
28
AVDD
29
AVSS
30
RG3
31
RG2
32
RG1
33
RG0
34
NC35
VSS
36
VDD
37
RG4
38
RG5
39
RG7
40
RG6
41
RA5
42
RA4
43
RA144
RA245
RA346
RB647
RB748
VDD49
OSC150
OSC251
NC52
VSS53
RB254
RB555
RB456
RB357
RB158
RB059
RA060
C46
0U1
X
R3
470K
R54
10K
C11220U
TRD
35V
C91N
COG
R26100K
C90100U16V
C20
1N
COG
R63
470
C101N
COG
R53
1K15
1%
L8
15UH TRD
U8
PCF8593T
OSC
I1
OSC
O2
RESE
T3
VSS
4SD
A5
SCL
6
INT
7
VPP
8
C59
0U1
X
R122
1K5
1206
L16
15UH
S1
R2210K
R117
56
TRD
1/2W
R19
100K
R115
470
R60
4K7
C17
0U1
X
D1
SM4004
R23
390
1206
R97
1K
R39140K
1%
R47
10K
R44
390
1206
X232K768
TRD
R30
100K
DS1
C6
0U1
X
L3
15UH
R51
10K
U1C
LM324
10
9
8-
+
C660U1
X
R70
100
D2
SM4004
C7
0U1
X
R66
10K
C2
100U
16V
6X6
R75
470
C67
0U1
X
R13110K
C400U1
X
R89
1K
1206
C1
0U1
X
C12
0U1
X
R35
1K5
C70
10N
X
R71
33K
C13
0U1
X
C62
0U1 X
C79
10N
X
R15
390
1206
C14100U
16V 6X6
C27
0U1
X
R102
100K
L1
15UH
R25
390
1206
R112
470K
R1
270
C151N
COG
U1A
LM324
3
2
1
411
+
-
C89
100U
16V
C320U1X
R56
10K
RV510KC
W
R77
470K
U2A
LM324
3
2
1
411
+
-
R32
100K
1%
R18
10K
R12
10K
L19
15UH
R52
10K
R132
39K
C310U1X
L22
15UHR74
470
EC12
DB18-MAS-90
10 15 11 16 12 17 13 18 14
5 9 4 8 3 7 2 6 1
R4
C22
1N
COG
R3710K
L20
15UH
C33
1N
COG
C84
10N
X
R73 56K
R78
470
U11B
LM358
5
6
7-
+
C91100U16V
R104
10K
R107
10K
D4
SM4004
L21
15UH
R69
10K
RV1
10K
CW
R101
10K
C64
0U1
X
R105
100K
R130
10K
L18
15UH
D9BAV99
2
3
1
R36
1K
C58
1U
X
C26
1N
COG
R27
100K
R33
10K
L4
15UH
L2
15UH
TRD
R28100K
C51
0U1
X
C73
10N
X
C48
1U
X
C83
10N
X
R82
470U3D
LM324
12
13
14-
+
R103
100K
R16100K
C37
10U
50V
6X6
EC5
AMP4PDIR
4 3 2 1
R5
C230U1
X
U2D
LM324
12
13
14-
+
R14
10K
CP1
TRD
R79
10K
C28
15P
R7
U3B
LM324
5
6
7-
+
L5
15UH
TRD
R108
10K
R109
10K
EC1
2X8PMASDIR
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
RL3
RELE-12V-1A-2SC
21 6 7 5 8
43
R129
470K
U1B
LM324
5
6
7+
-
R9
L10
15UH
TRD
R40
10K
C53
1N
COG
C45
1N
COG
C50
1N
COG
VB1
RV4
10K
CW
C65
0U1
X
R6
U2C
LM324
10
9
8+
-
C82
10N
X
C25
1N
COG
EC4
2X5PMASDIR
+ ESPULS
1 2
3 4
5 6
7 8
9 10
R21
10K
R86
8K2
C87
10N
X
L14
15UH
TRD
R106
100K
C81N
COG
R83
470
C54
0U1 X
R85
15K
C71
10N
X
R38
10K
C570U1
X
R41
100K
R93
27K
R20100K
EC3
2X13PMASDIR
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
R76
1K
1206
R4910K
C38
10-40P
R91100K
L6
15UH
TRD
C69
10N
X
LALARM1
LVSWR LPOWER
LALC
LDCOUT PDOWN
PENTER PUP
L2-DISPLAY
L1-DISPLAY LALARM
OVERL.P.S. OVERLOAD
ST-BY COM NEG SIG
IOUT MEAS
VOUT MEAS
REF MEAS
DIR MEAS
ST-BY IN POWER S. OVH OVHP
ST-BY OUT_1
ST-BY COM
RESET COM
RF OVH OVHR
ALLARME
EXC SWR-UNBAL EXCSWR
VOUT IOUT
ALC CTRL POWER S. OVH
ST-BY P.S. OVERL.P.S.
ST-BY OUT
ADREF PS ALLARME
L2-DISPLAY
FAN CONTROL
RESET COM
LALARM
+ 15/-15
REF INSTR LDISPLAY
FAN CONTROL DIR INSTR
OVHR
PENTER
XCOM LDISPLAY
3DB
VSWR L1-DISPLAY
REF DIR
EXC SWR-UNBAL RF OVH
RF1
IOUTS
ADREF LVSWR
OVHP
VOUTS
ST-BY P.S.
LALC
ST-BY OUT
LDCOUT
LPOWER
RF1
XCOM
XCOM
XCOM LALARM1
LDCOUT
ADREF PS
3dB
VOUTS
VREF5V
ALC CTRL VOUT MEAS
REF VOUT
IOUTS
IOUT
DIR IOUT MEAS
REF MEAS REF INSTR
ALC
DIR MEAS DIR INSTR
PUP ALC
PDOWN
OVERLOAD
EXCSWR
RESETA
ST-BY IN
ADREF
LVSWR
VSWR
LALC
VDD
VDD
VDD
VDD
VDD
+ 5
+ 15
+ 15
+ 15
+ 15
+ 15
+ 15
+ 5
VDD VDD
+ 15
+ 15 + 15
+ 15
+ 15
+ 15 + 15
VDD
VDD
+ 5
+ 5
+ 5
VDD
+ 15
+ 5 + 5
VDD
VDD
VDD
+ 5
+ 15
+ 15 + 15
VDD
+ 15VDD
-15
-15
-15
-15
-15 -15
-15
-15
+ 5
VDD
+ 15
D7
R/W
I/D
RESET
ALLARMI
45
DB15-2
56
33
24
55
48
12
JP2
13
47
31
60
JP1
44
JP1
34
28
22
23
59
CS
TO
POWER SUPPLY
TO RF MODUL
D0
D1
D2
D3
D4
D5
D6
-3dB
REF
DIR REF
INST
DIR
INST
CURR
INST
VOLT
INST
RESET
PASSWD
ON/OFF
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 66 – Release 2.0
HANU1
HANU2
HANU3HANU4
META SYSTEM PROPERTY ALL RIGHT RESERVED ART. 1151-1/2/3
CODICE:^ K
TITOLO:
DATA:
IL TECNICO PROGETTISTA:
IL TECNICO DISEGNATORE:
SCALA:
___________________________
___________________________
RIFERIM. X:
R
METASYSTEM
R
C89
C90
D8
C91
1EEC5
C1
C10
+
-
C11
C12
C13
C14
C15
C16
C17
C18
C19
C2
C20
C21
C22
C23
C24
C25
C26
C27
C28C29
C3
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C4
C40
C41
C42
C43
C44
C45
C46
C47
C48
C49
C5
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C6
C60
C62
C63 C
64C
65
C66
C7
C8
C9
CP1
D1
D2
D3
D4
D5
D6
D7
DZ1
1E2
1516
EC1
1E2
9510
EC2
L1
L10
L11
L12
L13
L14
L15
L16
L17
L18
L19
L2
L20L21
L22
L3
L4
L5
L6
L7
L8
L9
EC7
EC12
EC9
Q1
Q2
Q3
Q4
Q5
R1
R10
R11
R12
R13
R14
R15
R16
R17
R18
R19
R2
R20
R21
R22
R23
R24
R25
R26
R27
R28
R29
R3
R30
R31
R32
R33
R35
R36
R37
R38
R39
R4
R40
R41
R42
R43
R44
R45
R46
R47
R48
R49
R5
R50
R51
R52
R53
R54
R55
R56
R57
R58
R59
R6
R60
R61
R62 R6
3
R64
R65
R66
R67
R68
R69
R7
R70
R71
R72
R73
R74
R75
R76
R77
R78
R79
R8
R80
R81
R82
R83
R84
R85
R86
R87
R88
R89
R9
R90
R91
R92
R93
R94
R95
R96
CM1 CM2
NA1 NA2
NC1 NC2
+-
RL1
CM1CM2
NA1NA2
NC1NC2
+ -
RL2
CM1 CM2
NA1 NA2
NC1 NC2
+-
RL3
1M 38
RV1
1M 38
RV2
1M 38
RV3
1M 38
RV4
1M 38RV5
1M 38
RV6
1M 38
RV7
CM
1
CM
1C
M2
CM
2
S1
1M 4^K
5^O
8
U11
1M
4^ K 5^ O
8
U12
1M7^K
8^O
14U1
1M7^K
8^O
14U2
1M7^K
8^O
14U3
1M4^K
5^O
8
U4
U5
1M
4^K5^O
8
U61M
18
35
52
U7
1M
4^K5^O
8
U8
1M 8895
16
U9X1
X2
1M7^K
8^O
14U13
C67
R97
R98
R99Q6
C68
C69
C70
C71C72
C73 C74
C75
C76
C77
C78C79
C82C83
C84
C85C86
C87
R100
R101
1E 2
25 26
EC3
D9
R102
R103
R104
R105
R106
R107
R108
R109
R110
R111
R112
R113
R114
R115
R117
R121
R122
1E2
9510
EC4
D10
D11
R116
R119
R123
R124
R125
D12D13
Q7Q8
R126
R127
R128
1E
EC13
JP2
R34
R129
R130
R131
R132
3:2
ALLEGRI
S3115D01 26/09/2000
SCHEDA CONTROLLER VL1000 PLUS
SCORTICATI
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 67 – Release 2.0
CONTROLLER VL1000 PLUS Revised: Thursday, March 01, 2001 S3115D01.SCH Revision: ?
META SYSTEM S.P.A. Property all rights reserved art.1151-1/2/3 Resp.Tecnico: Allegri Disegnatore: Scorticati
Bill Of Materials October 9,2001 11:47:52
Page1
Comp. No. Stock No. designation Manufacturer designation
A1 I01978 PIC17C756A TRD MICROCHIP PIC17C756AT C1 C3610F 0U1 X MURATA GRM40X7R104K25 C2 C43101 100U 16V 6X6 NIC NACE101M16VTR C3 C3410B 1N COG MURATA GRM40COG102J50 C4 C2310C 100U TRD 25V ELNA RE2-025V101M C5 C3610F 0U1 X MURATA GRM40X7R104K25 C6 C3610F 0U1 X MURATA GRM40X7R104K25 C7 C3610F 0U1 X MURATA GRM40X7R104K25 C8 C3410B 1N COG MURATA GRM40COG102J50 C9 C3410B 1N COG MURATA GRM40COG102J50 C10 C3410B 1N COG MURATA GRM40COG102J50 C11 C2322F 220U TRD 35V ELNA RE2-035V221M C12 C3610F 0U1 X MURATA GRM40X7R104K25 C13 C3610F 0U1 X MURATA GRM40X7R104K25 C14 C43101 100U 16V 6X6 NIC NACE101M16VTR C15 C3410B 1N COG MURATA GRM40COG102J50 C16 C3610F 0U1 X MURATA GRM40X7R104K25 C17 C3610F 0U1 X MURATA GRM40X7R104K25 C18 C3410B 1N COG MURATA GRM40COG102J50 C19 C3410B 1N COG MURATA GRM40COG102J50 C20 C3410B 1N COG MURATA GRM40COG102J50 C21 C3610F 0U1 X MURATA GRM40X7R104K25 C22 C3410B 1N COG MURATA GRM40COG102J50 C23 C3610F 0U1 X MURATA GRM40X7R104K25 C24 C3410B 1N COG MURATA GRM40COG102J50 C25 C3410B 1N COG MURATA GRM40COG102J50 C26 C3410B 1N COG MURATA GRM40COG102J50 C27 C3610F 0U1 X MURATA GRM40X7R104K25 C28 C3215B 15P COG MURATA GRM40COG150J50 C29 C3215B 15P COG MURATA GRM40COG150J50 C30 C3610F 0U1 X MURATA GRM40X7R104K25
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 68 – Release 2.0
C31 C3610F 0U1 X MURATA GRM40X7R104K25 C32 C3610F 0U1 X MURATA GRM40X7R104K25 C33 C3410B 1N COG MURATA GRM40COG102J50 C34 C42106 10U 50V 6X6 ELNA RV2-50V100M-R C35 C42106 10U 50V 6X6 ELNA RV2-50V100M-R C36 C42106 10U 50V 6X6 ELNA RV2-50V100M-R C37 C42106 10U 50V 6X6 ELNA RV2-50V100M-R C38 C05067 10-40P MURATA TZBX4P400BB110T00 C39 C42106 10U 50V 6X6 ELNA RV2-50V100M-R C40 C3610F 0U1 X MURATA GRM40X7R104K25 C41 C3610F 0U1 X MURATA GRM40X7R104K25 C42 C3410B 1N COG MURATA GRM40COG102J50 C43 C42106 10U 50V 6X6 ELNA RV2-50V100M-R C44 C3610F 0U1 X MURATA GRM40X7R104K25 C45 C3410B 1N COG MURATA GRM40COG102J50 C46 C3610F 0U1 X MURATA GRM40X7R104K25 C47 C3610F 0U1 X MURATA GRM40X7R104K25 C48 C3710F 1U X MURATA GRM21BR71A105K C49 C3410F 1N X MURATA GRM40X7R102K50 C50 C3410B 1N COG MURATA GRM40COG102J50 C51 C3610F 0U1 X MURATA GRM40X7R104K25 C52 C3610F 0U1 X MURATA GRM40X7R104K25 C53 C3410B 1N COG MURATA GRM40COG102J50 C54 C3610F 0U1 X MURATA GRM40X7R104K25 C55 C3610F 0U1 X MURATA GRM40X7R104K25 C56 C3610F 0U1 X MURATA GRM40X7R104K25 C57 C3610F 0U1 X MURATA GRM40X7R104K25 C58 C3710F 1U X MURATA GRM21BR71A105K C59 C3610F 0U1 X MURATA GRM40X7R104K25 C60 C3410B 1N COG MURATA GRM40COG102J50 C62 C3610F 0U1 X MURATA GRM40X7R104K25 C63 C3410B 1N COG MURATA GRM40COG102J50 C64 C3610F 0U1 X MURATA GRM40X7R104K25 C65 C3610F 0U1 X MURATA GRM40X7R104K25 C66 C3610F 0U1 X MURATA GRM40X7R104K25 C67 C3610F 0U1 X MURATA GRM40X7R104K25 C68 C3510F 10N X MURATA GRM40X7R103K50 C69 C3510F 10N X MURATA GRM40X7R103K50 C70 C3510F 10N X MURATA GRM40X7R103K50 C71 C3510F 10N X MURATA GRM40X7R103K50 C72 C3510F 10N X MURATA GRM40X7R103K50 C73 C3510F 10N X MURATA GRM40X7R103K50 C74 C3510F 10N X MURATA GRM40X7R103K50 C75 C3510F 10N X MURATA GRM40X7R103K50 C76 C3510F 10N X MURATA GRM40X7R103K50 C77 C3510F 10N X MURATA GRM40X7R103K50 C78 C3510F 10N X MURATA GRM40X7R103K50 C79 C3510F 10N X MURATA GRM40X7R103K50 C82 C3510F 10N X MURATA GRM40X7R103K50
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 69 – Release 2.0
C83 C3510F 10N X MURATA GRM40X7R103K50 C84 C3510F 10N X MURATA GRM40X7R103K50 C85 C3510F 10N X MURATA GRM40X7R103K50 C86 C3510F 10N X MURATA GRM40X7R103K50 C87 C3510F 10N X MURATA GRM40X7R103K50 C89 C43101 100U 16V 6X6 NIC NACE101M16VTR C90 C43101 100U 16V 6X6 NIC NACE101M16VTR C91 C43101 100U 16V 6X6 NIC NACE101M16VTR CP1 E10000 CONT-PILE-SMD TRD METASYSTEM E10000 D1 D05021 SM4004 PHILIPS S1G D2 D05021 SM4004 PHILIPS S1G D3 D05006 BAV99 PHILIPS BAV99 D4 D05021 SM4004 PHILIPS S1G D5 D05006 BAV99 PHILIPS BAV99 D6 D05002 BAV70 PHILIPS BAV70 D7 D05011 BAW56 PHILIPS BAW56 D8 D05021 SM4004 PHILIPS S1G D9 D05006 BAV99 PHILIPS BAV99 D10 D05006 BAV99 PHILIPS BAV99 D11 D05006 BAV99 PHILIPS BAV99 D12 D05011 BAW56 PHILIPS BAW56 D13 D05011 BAW56 PHILIPS BAW56 DS1 G00003 DISSIP TRD TO220 PADA ENG. 8100/25/N DZ1 D01682 BZX84-6V8 PHILIPS BZX84-C-6V8 EC1 E05603 2X8PMASDIR TRD NL INDUSTRIES MFCB16Y EC2 E05601 2X5PMASDIR TRD NL INDUSTRIES MFCB10Y EC3 E05604 2X13PMASDIR TRD BREDI ELET. H311-026P EC4 E05601 2X5PMASDIR TRD NL INDUSTRIES MFCB10Y EC5 E04330 AMP4PDIR TRD AMP 0-0280371-1 EC7 E0405S DB15-FEM-90 TRD CS NL INDUSTRIES F15MWC06 EC9 E04043 DB9-FEM-90 TRD NL INDUSTRIES F9MWC06 EC12 E0405B DB18-MAS-90 TRD NL INDUSTRIES FM9TW1AU30 EC13 E04320 AMP2PDIR TRD AMP 0-0280370-1 JP2 E04300 HE-13/14-2P TRD LUMBERG 2.5 MS02 JP7 E04300 HE-13/14-2P TRD LUMBERG 2.5 MS02 L1 M12150 15UH SIEMENS B8242A1153K100 L2 M00086 15UH TRD SIEMENS B78108S1153K L3 M12150 15UH SIEMENS B8242A1153K100 L4 M12150 15UH SIEMENS B8242A1153K100 L5 M00086 15UH TRD SIEMENS B78108S1153K L6 M00086 15UH TRD SIEMENS B78108S1153K L7 M00086 15UH TRD SIEMENS B78108S1153K L8 M00086 15UH TRD SIEMENS B78108S1153K L9 M12150 15UH SIEMENS B8242A1153K100 L10 M00086 15UH TRD SIEMENS B78108S1153K L11 M00086 15UH TRD SIEMENS B78108S1153K L12 M00086 15UH TRD SIEMENS B78108S1153K L13 M00086 15UH TRD SIEMENS B78108S1153K L14 M00086 15UH TRD SIEMENS B78108S1153K
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 70 – Release 2.0
L15 M12150 15UH SIEMENS B8242A1153K100 L16 M12150 15UH SIEMENS B8242A1153K100 L17 M12150 15UH SIEMENS B8242A1153K100 L18 M12150 15UH SIEMENS B8242A1153K100 L19 M12150 15UH SIEMENS B8242A1153K100 L20 M12150 15UH SIEMENS B8242A1153K100 L21 M12150 15UH SIEMENS B8242A1153K100 L22 M12150 15UH SIEMENS B8242A1153K100 Q1 T05001 BC817 PHILIPS BC817-25 Q2 T05001 BC817 PHILIPS BC817-25 Q3 T05001 BC817 PHILIPS BC817-25 Q4 T05001 BC817 PHILIPS BC817-25 Q5 T05421 IRLML2803 IR IRLML2803 Q6 T05001 BC817 PHILIPS BC817-25 Q7 T05003 BC807 PHILIPS BC807-25 Q8 T05001 BC817 PHILIPS BC817-25 R1 R23271 270 0805 SIEMENS B54102A1 271J60 R2 R25221 22K 0805 SIEMENS B54102A1 223J60 R3 R26471 470K 0805 SIEMENS B54102A1 474J60 R4 R26471 470K 0805 SIEMENS B54102A1 474J60 R5 R26471 470K 0805 SIEMENS B54102A1 474J60 R6 R26471 470K 0805 SIEMENS B54102A1 474J60 R7 R26471 470K 0805 SIEMENS B54102A1 474J60 R8 R26471 470K 0805 SIEMENS B54102A1 474J60 R9 R26471 470K 0805 SIEMENS B54102A1 474J60 R10 R26471 470K 0805 SIEMENS B54102A1 474J60 R11 R26101 100K 0805 SIEMENS B54102A1 104J60 R12 R25101 10K 0805 SIEMENS B54102A1 103J60 R13 R23390 390 1206 SIEMENS B54103A1 391J60 R14 R25101 10K 0805 SIEMENS B54102A1 103J60 R15 R23390 390 1206 SIEMENS B54103A1 391J60 R16 R26101 100K 0805 SIEMENS B54102A1 104J60 R17 R25101 10K 0805 SIEMENS B54102A1 103J60 R18 R25101 10K 0805 SIEMENS B54102A1 103J60 R19 R26101 100K 0805 SIEMENS B54102A1 104J60 R20 R26101 100K 0805 SIEMENS B54102A1 104J60 R21 R25101 10K 0805 SIEMENS B54102A1 103J60 R22 R25101 10K 0805 SIEMENS B54102A1 103J60 R23 R23390 390 1206 SIEMENS B54103A1 391J60 R24 R25101 10K 0805 SIEMENS B54102A1 103J60 R25 R23390 390 1206 SIEMENS B54103A1 391J60 R26 R26101 100K 0805 SIEMENS B54102A1 104J60 R27 R26101 100K 0805 SIEMENS B54102A1 104J60 R28 R26101 100K 0805 SIEMENS B54102A1 104J60 R29 R26101 100K 0805 SIEMENS B54102A1 104J60 R30 R26101 100K 0805 SIEMENS B54102A1 104J60 R31 R25101 10K 0805 SIEMENS B54102A1 103J60 R32 R56100 R36100 100K 0805 1% SIEMENS B54102A2 104F060 R33 R25101 10K 0805 SIEMENS B54102A1 103J60
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 71 – Release 2.0
R34 R26101 100K 0805 SIEMENS B54102A1 104J60 R35 R24151 1K5 0805 SIEMENS B54102A1 152J60 R36 R24101 1K 0805 SIEMENS B54102A1 102J60 R37 R25101 10K 0805 SIEMENS B54102A1 103J60 R38 R25101 10K 0805 SIEMENS B54102A1 103J60 R39 R56140 140K 0805 1% SIEMENS B54102A2 144F060 R40 R25101 10K 0805 SIEMENS B54102A1 103J60 R41 R26101 100K 0805 SIEMENS B54102A1 104J60 R42 R26331 330K 0805 SIEMENS B54102A1 334J60 R43 R23390 390 1206 SIEMENS B54103A1 391J60 R44 R23390 390 1206 SIEMENS B54103A1 391J60 R45 R27101 1M 0805 SIEMENS B54102A1 105J60 R46 R25101 10K 0805 SIEMENS B54102A1 103J60 R47 R25101 10K 0805 SIEMENS B54102A1 103J60 R48 R24151 1K5 0805 SIEMENS B54102A1 152J60 R49 R25101 10K 0805 SIEMENS B54102A1 103J60 R50 R24221 2K2 0805 SIEMENS B54102A1 222J60 R51 R25101 10K 0805 SIEMENS B54102A1 103J60 R52 R25101 10K 0805 SIEMENS B54102A1 103J60 R53 R54115 1K15 0805 1% SIEMENS B54102A2 112F560 R54 R25101 10K 0805 SIEMENS B54102A1 103J60 R55 R55100 10K 0805 1% SIEMENS B54102A2 103F060 R56 R25101 10K 0805 SIEMENS B54102A1 103J60 R57 R24681 6K8 0805 SIEMENS B54102A1 682J60 R58 R25101 10K 0805 SIEMENS B54102A1 103J60 R59 R24100 1K 1206 SIEMENS B54103A1 102J60 R60 R24471 4K7 0805 SIEMENS B54102A1 472J60 R61 R25101 10K 0805 SIEMENS B54102A1 103J60 R62 R23471 470 0805 SIEMENS B54102A1 471J60 R63 R23471 470 0805 SIEMENS B54102A1 471J60 R64 R26471 470K 0805 SIEMENS B54102A1 474J60 R65 R24221 2K2 0805 SIEMENS B54102A1 222J60 R66 R25101 10K 0805 SIEMENS B54102A1 103J60 R67 R25101 10K 0805 SIEMENS B54102A1 103J60 R68 R25471 47K 0805 SIEMENS B54102A1 473J60 R69 R25101 10K 0805 SIEMENS B54102A1 103J60 R70 R23101 100 0805 SIEMENS B54102A1 101J60 R71 R25331 33K 0805 SIEMENS B54102A1 333J60 R72 R25151 15K 0805 SIEMENS B54102A1 153J60 R73 R25561 56K 0805 SIEMENS B54102A1 563J60 R74 R23471 470 0805 SIEMENS B54102A1 471J60 R75 R23471 470 0805 SIEMENS B54102A1 471J60 R76 R24100 1K 1206 SIEMENS B54103A1 102J60 R77 R26471 470K 0805 SIEMENS B54102A1 474J60 R78 R23471 470 0805 SIEMENS B54102A1 471J60 R79 R25101 10K 0805 SIEMENS B54102A1 103J60 R80 R26101 100K 0805 SIEMENS B54102A1 104J60 R81 R25471 47K 0805 SIEMENS B54102A1 473J60 R82 R23471 470 0805 SIEMENS B54102A1 471J60
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 72 – Release 2.0
R83 R23471 470 0805 SIEMENS B54102A1 471J60 R84 R25471 47K 0805 SIEMENS B54102A1 473J60 R85 R25151 15K 0805 SIEMENS B54102A1 153J60 R86 R24821 8K2 0805 SIEMENS B54102A1 822J60 R87 R54560 5K6 0805 1% SIEMENS B54102A2 562F060 R88 R55180 18K 0805 1% SIEMENS B54102A2 183F060 R89 R24100 1K 1206 SIEMENS B54103A1 102J60 R90 R25151 15K 0805 SIEMENS B54102A1 153J60 R91 R26101 100K 0805 SIEMENS B54102A1 104J60 R92 R23471 470 0805 SIEMENS B54102A1 471J60 R93 R25271 27K 0805 SIEMENS B54102A1 273J60 R94 R23471 470 0805 SIEMENS B54102A1 471J60 R95 R23471 470 0805 SIEMENS B54102A1 471J60 R96 R25471 47K 0805 SIEMENS B54102A1 473J60 R97 R24101 1K 0805 SIEMENS B54102A1 102J60 R98 R24471 4K7 0805 SIEMENS B54102A1 472J60 R99 R25101 10K 0805 SIEMENS B54102A1 103J60 R100 R25101 10K 0805 SIEMENS B54102A1 103J60 R101 R25101 10K 0805 SIEMENS B54102A1 103J60 R102 R26101 100K 0805 SIEMENS B54102A1 104J60 R103 R26101 100K 0805 SIEMENS B54102A1 104J60 R104 R25101 10K 0805 SIEMENS B54102A1 103J60 R105 R26101 100K 0805 SIEMENS B54102A1 104J60 R106 R26101 100K 0805 SIEMENS B54102A1 104J60 R107 R25101 10K 0805 SIEMENS B54102A1 103J60 R108 R25101 10K 0805 SIEMENS B54102A1 103J60 R109 R25101 10K 0805 SIEMENS B54102A1 103J60 R110 R26471 470K 0805 SIEMENS B54102A1 474J60 R111 R25101 10K 0805 SIEMENS B54102A1 103J60 R112 R26471 470K 0805 SIEMENS B54102A1 474J60 R113 R25101 10K 0805 SIEMENS B54102A1 103J60 R114 R25101 10K 0805 SIEMENS B54102A1 103J60 R115 R23471 470 0805 SIEMENS B54102A1 471J60 R116 R23470 470 1206 SIEMENS B54103A1 471J60 R117 R00212 56 TRD 1/2W ROY CR50PS 56 OHMJ R119 R23470 470 1206 SIEMENS B54103A1 471J60 R121 R00222 68 TRD 1/2W ROY CR50PS 56 OHMJ R122 R24150 1K5 1206 SIEMENS B54103A1 152J60 R123 R23680 680 1206 SIEMENS B54103A1 681J60 R124 R23680 680 1206 SIEMENS B54103A1 681J60 R125 R23680 680 1206 SIEMENS B54103A1 681J60 R126 R25101 10K 0805 SIEMENS B54102A1 103J60 R127 R24221 2K2 0805 SIEMENS B54102A1 222J60 R128 R24101 1K 0805 SIEMENS B54102A1 102J60 R129 R26471 470K 0805 SIEMENS B54102A1 474J60 R130 R25101 10K 0805 SIEMENS B54102A1 103J60 R131 R25101 10K 0805 SIEMENS B54102A1 103J60 R132 R25391 39K 0805 SIEMENS B54102A1 393J60 RL1 E02056 RELE-12V-1A-2SC TRD OMRON G5V-2-H1 12VCC
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 73 – Release 2.0
RL2 E02056 RELE-12V-1A-2SC TRD OMRON G5V-2-H1 12VCC RL3 E02056 RELE-12V-1A-2SC TRD OMRON G5V-2-H1 12VCC RV1 R0518 10K TRD ORIZ BOURNS 3386P-1-103 RV2 R0518 10K TRD ORIZ BOURNS 3386P-1-103 RV3 R0518 10K TRD ORIZ BOURNS 3386P-1-103 RV4 R0518 10K TRD ORIZ BOURNS 3386P-1-103 RV5 R0518 10K TRD ORIZ BOURNS 3386P-1-103 RV6 R0518 10K TRD ORIZ BOURNS 3386P-1-103 RV7 R0518 10K TRD ORIZ BOURNS 3386P-1-103 S1 E00055 PULS OMRON B3S1002P U1 I01400 LM324 SAMSUNG KA324DTF U2 I01400 LM324 SAMSUNG KA324DTF U3 I01400 LM324 SAMSUNG KA324DTF U4 I01809 L4949 MOTOROLA L4949DR2 U5 I00403 7805 TRD ST L7805CV U6 I01957 ST93C86 ST M93C86 U7 E10900 ZOCCOLO SMD CONNEX D0368TBA2 U8 I01937 PCF8593T PHILIPS PCF8593T U9 I01958 DS14C232 HARRIS ICL232CBE U11 I01401 LM358 SAMSUNG KA358D U12 I01979 DS75176B NATIONAL DS75176BM U13 I01241 74HC4066 PHILIPS 74HC4066D VB1 VO114 V0114
G11062 KIT-2PILE-LITIO TRD PANASONIC CR1220
X1 A05519 16MHZ 3PIN MURATA CSTCS16.00MXA040Q-TCX2 A05019 32K768 TRD KYOCERA KF-38G-12P0200
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 74 – Release 2.0
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
S3120B.SCH
INTERC.RETROP.VL1000/VL500 PLUS
META SYSTEM S.p.a.
Property all rights reserved art.1151-1/2/3
Il tecnico progettista: Allegri M.
Il tecnico disegnatore: Scorticati Stefano
A
0 0Thursday, April 19, 2001
Title
Size Document Number Rev
Date: Sheet of
D1
MAS16P
12345678910111213141516
EC2
2X13PMASDIR
TRD
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
H1 DISPLAY
ALFANUM-2RIG
12345678910111213141516
EC1
MAS10P
1 2 3 4 5 6 7 8 9 10
1000W VHF FM AMPLIFIER VL1000 PLUS
Service and Operat ing Manual
- 75 – Release 2.0
D1
EC1
12
2526
EC2
H1H2
META SYSTEM PROPERTY ALL RIGHT RESERVED ART. 1151-1/2/3
CODICE:
TITOLO:
DATA:
IL TECNICO PROGETTISTA:
IL TECNICO DISEGNATORE:
SCALA: 2:1
___________________________
___________________________
RIFERIM. X:
R
METASYSTEM RINTERCONN. RETROPANN. VL1000 PLUS
ALLEGRI
CAVALCABUES3120B 11-09-00
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 76 – Release 2.0
CONNECTION REAR PANEL VL1000 PLUS Revised: Tuesday, October 09, 2001 S3120B.SCH Revision: ?
META SYSTEM S.p.a. Property all rights reserved art.1151-1/2/3 Il tecnico progettista: Allegri M. Il tecnico disegnatore: Scorticati Stefano
Bill Of Materials October 9,2001 12:20:43
Page1
Comp.No. Stock No. Designation Manufacturer Designation
D1 E04302 HE-13/14-40P TRD MAS16P LUMBERG 2.5 MS 40 EC1 E04302 HE-13/14-40P TRD MAS10P LUMBERG 2.5 MS 40 EC2 E05604 2X13PMASDIR TRD BREDI E. H311-026P H1 A01006 DISPLAY TRD 2RIGHE POWERTIP PC1602LRU-CSO-E-Y4
1000W VHF FM AMPLIFIER VL1000 PLUS Service and Operat ing Manual
- 77 – Release 2.0
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
D D
C C
B B
A A
keyboard VL1000/VL500 PLUS
META SYSTEM S.p.a.
Property all rights reserved art.1151-1/2/3
Il tecnico progettista: Motti
Il tecnico disegnatore: Scorticati Stefano
A
0 0Wednesday, February 28, 2001
Size Document Number Rev
Date: Sheet of
VERDE
1
2
3
4
5
6
7
8
9
10
ROSSO
ENTER
VERDE ROSSOVERDE
DOWN UP
DC OUT ALC VSWR ALARM POWER
4[AA1]CTE: il testo contenuto all’interno degli schemi è ancora in italiano e riporta VL 1000 Plus, nonché Meta Systems 10[AA2]CTE: questo capitolo va rivisto completamente. Non so per quante ore siano garantite le ventole. Inoltre mi mancano altri riferimenti 20[AA3]CTE: inserirò il disegno della Code Card 23[AA4]Vedere se fare tabella