Upload
padam-dhanuk
View
213
Download
0
Embed Size (px)
Citation preview
7/31/2019 103253 Be
1/76
DSX-1Digia Siga Cross-Coec adDigia Siga Iercoec Prodcs
3rd Edition
COPPER COnnECtIvIty SOlutIOnS
7/31/2019 103253 Be
2/76
7/31/2019 103253 Be
3/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
3T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSX-1tabe o Coes
Introduction
Cross-Coec Ssem ..................................................................................................................1
Coecig wih yor nework..................................................................................................2-3
Bantam Jack Technology Features .................................................................................................4
Panel Configuration Features .......................................................................................................5
Skeleton Bay Lineup Features .....................................................................................................6-7
Product Family Features ................................................................................................................8
DSXi Family
Irodcio Desig Eemes .........................................................................................................9
84-termiaio Rear Cross-Coec Paes .................................................................................10
64-termiaio Rear Cross-Coec Paes .................................................................................11
56-Termination Rear Cross-Connect Panels .................................................................................12
84-Termination Front Cross-Connect Panels ................................................................................13
64-Termination Front Cross-Connect Panels ................................................................................14
56-Termination Front Cross-Connect Panels ................................................................................1584-Termination Total Front Access Cross-Connect Panels .............................................................16
64-Termination Total Front Access Cross-Connect Panels .............................................................17
56-Termination Total Front Access Cross-Connect Panels .............................................................18
Rear Cross-Connect Skeleton Bays ..............................................................................................19
Front Cross-Connect Skeleton Bays .............................................................................................20
Rack Hardware ......................................................................................................................21-22
FlexDSX Family
Irodcio Desig Eemes ..................................................................................................23-24
84-termiaio Rear Cross-Coec Paes .................................................................................25
84-Termination Front Cross-Connect Panels ................................................................................26
64-Termination Front Cross-Connect Panels ................................................................................2756-Termination Front Cross-Connect Panels ................................................................................28
Front or Rear Cross-Connect Skeleton Bays .................................................................................29
Rack Hardware ......................................................................................................................30-31
Super High-Density Bay and Rear Cross-Connect System ........................................................32-34
Specialty Panels
FlexDSX Multifunction Panel ..................................................................................................35-36
Modular DS1/DS3 Combination Panel.........................................................................................37
Rear Access Interconnect Modular System
Irodcio ....................................................................................................................................38
56-Termination Interconnect Panel..............................................................................................39
DDP-1 Panels ..............................................................................................................................4084-Termination DDP-1 Panel ...................................................................................................41
56-Termination DDP-1 Panel ...................................................................................................42
Jack Cards ..............................................................................................................................43
7/31/2019 103253 Be
4/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
4T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSX-1tabe o Coes
Auxiliary Equipment
Cross Aisle Panels ..................................................................................................................44-45
Ierba Pach Paes .............................................................................................................46-47
Bay Tracer Imiaor ................................................................................................................48
DS1 Repeaters .......................................................................................................................49-50
Commicaios Paes ..............................................................................................................51
Communications Panel Accessories and Writing Shelves .............................................................52
Fuse Panels .................................................................................................................................53
Horizoa Cabe troghs ............................................................................................................54
Horizoa Rig Paes ................................................................................................................54
Accessories
Bantam Plugs..............................................................................................................................55
termiaig Pgs ...................................................................................................................55
Looping Plugs.........................................................................................................................55
Hoe Pgs ..............................................................................................................................55Conversion Plugs ....................................................................................................................55
Dmm Pgs .........................................................................................................................55
Circi Gard Pgs .................................................................................................................56
Orderig Iormaio ..............................................................................................................57
Pach Cords ................................................................................................................................58
three-Codcor ....................................................................................................................58
Conversion .............................................................................................................................59
Patch Cords Specialty ...............................................................................................................60
Alligator Patch Cords ..............................................................................................................60
EZ Hook Pach Cords ..............................................................................................................60
Banana-Type Patch Cords .......................................................................................................60
BNC to Bantam Plug Patch Cords ...........................................................................................61RJ11 Telephone Plug to Bantam Plug Patch Cords...................................................................61
Bantam Plug to AT&T 800 Style Plug Patch Cords ...................................................................61
Orderig Iormaio ..............................................................................................................62
Pach Cords Accessory Kits ......................................................................................................63
Pach Cords Controlled Environment Vault Kits .......................................................................64
Cross-Connect Wire....................................................................................................................65
Wire-Wrap Tool Kits ....................................................................................................................65
Replacement LED Modules..........................................................................................................66
Index ......................................................................................................................................................... 67-69
7/31/2019 103253 Be
5/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
1T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Increased demand for optimal networkperformance has created a greater need forreliable connectivity equipment. ADC KRONEsdigital signal cross-connect (DSX) productsprovide a competitive advantage by managingdigital equipment and maintaining superiorcable management. DSX equipment is used asa ceraized cross-coec ierace beweenetwork elements (NE), enabling nonintrusive andintrusive access for testing, patching, and circuitreconfiguration without disturbing permanentequipment connections.
techoog
The DSX interface enables patching, terminating
and rearranging of circuits as traffic patternschage ad demads o he ework grow.At DS1 (1.544 Mbps) digital signal rates, DSXequipment connects NEs such as office repeaters,digital switches, channel banks, digital loopcarriers, multiplexers, and digital loop switches.
Each NE is permanently cabled to a DSX-1terminal. Any two NEs can be connected toeach oher i a odedicaed maer b measof a semi-permanent cross-connect jumperbetween two DSX-1 terminations. The cross-connect jumper allows flexibility for futurenetwork reconfiguration. Internal jack circuits
provide input/output connections to each digitalsiga sorce.
DSX equipment consists of four basic elements:
IN/OUT Terminations: Permaely coecs
he nE o he DSX ierface.
Cross-Connect Terminations: Coecs hewo DSX ocaios carrig he sigas romhe nEs. the ework diagram below showsthe semi-permanent connections between DSXequipment.
Jacks: IN and OUT switching jacks allow accessto the NE's input and output signals for testand patching operations. A MONITOR jack isconnected to the OUT jack for nonintrusiveaccess to the output signal. Dual MONITORjacks provide bidirectional signal monitoring
rom oe ocaio. LEDs: Flashing LEDs at each end of the DSX
circuit quickly and easily identify the cross-coeced circi.
IntroductionCross-Coec Ssem
Cross-ConnectJumper
OUT
IN
DSX-1
EquipmentCable
Network
Element A
Tx OUTOUT OUT
IN INRx IN
X-OUT
X-IN
M
O
I
DSX-1
EquipmentCable
Network
Element B
Tx OUTX-OUT
X-IN Rx IN
Out
MON MON
IN
Application
The management of equipment cables and cross-connect jumpers is addressed at the DSX bayframework, ensuring an organized and expandable network. The DSX system should be placed in acentralized location. Whether in a central office, remote site, or wireless bay station or hub, DSX deliversa flexible centralized location to access and monitor network signals.
DSX Semi-Permanent Connections
7/31/2019 103253 Be
6/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
2T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Cross-connection encourages seamless expansion,simple rerouting and quick restoration for today'sevolving networks.
Reduce costs; increase revenues; satisfy customersthe tenets of service providers as they balancetodays tenuous financial climate with the promiseof next-generation products and services. Andas networks migrate and expand to includemore complex services, reliability and flexibilitybecome even more vital to their success. That iswh digia ssem cross-coec (DSX) soiosremain the best option for connecting networkeemes.
The deployment of DSX platforms eases networkexpansion; allows circuit access for nonintrusive
testing, monitoring, and patching; and establishesa central termination point for efficient circuitrearrangements. It allows operators to add amigration of technological platforms and bringadvanced services closer to customers whilepreserving integrity at the networks core.
Make the Connection
teecommicaios eworks ms be desigedo seamess absorb ew growh, accommodaewiring changes, and restore failed circuits quickly.In its journey from source to destination, a signal
travels through a gamut of telecommunicationsequipment that transforms, grooms, multiplexes,switches, demultiplexes, and routes the signal.Operators have three accepted methods ofrouting this signal: direct connect, interconnect,and cross-connect via a DSX. Direct connectionad iercoecio ser rom sigiicalimitations, but the DSX remains fully capable ofproviding optimal flexibility, reliability, and accesso he ework.
DSX, coupled with a robust connectivityinfrastructure, enhances several work operations:
Faster service provisioning with greater capacity Increased service reliability and protection of
electronic equipment and network elements
Fundamental maintenance including physicalaer access
Quicker service recovery
Simple, uncomplicated rollovers in futurenetwork migration planning
Nonintrusive network element replacementad esig
Connectivity typically accounts for 1% to 10%of the upfront costs of network deployment. Asmall investment to simplify procedures, reduceerrors, and minimize outages. Many networkperformance problems stem from restrictedaccess or maieace, cabe cogesio,rerouting or monitoring capabilities. And eachproblem is a high-maintenance propositioncharacterized by longer service interruptions,operational inefficiency, and frustrated customersthat can be easily averted with a DSX solution.
But there is more to connecting a network thansimply running cables between network elements.
Network design plays a crucial role in determiningwhether a network will generate revenue or lose
profitability through excess labor costs and missedservice opportunities.
Network design is evaluated against three criteria:
Flexibility
Central termination point
Circuit access
FlexibilityChange is inevitable. In todays dynamic,evolving networks, it isnt a matter of if thingswill changeits a matter of how much. Todays
commicaios eworks demad a migraioplatform equipped with the cable managementand physical rearrangement flexibility toaccommodate new services and networkelements. Todays networks demand the flexibilityo DSX.
uike a direc coec soio, where eworkeemes are direc coeced o oe aoherin a dedicated, pre-assigned method, a DSXsolution serves as the demarcation point. Thislimits faults to individual circuits only, allowingchanges to be performed with minimal recablingad abor coss.
Direct connection forces operators to locatecables and then pull them to new locations,resulting in an extensive, intrusive reengineeringprocess that demands a great deal of timead moe recabig each ework eeme.In contrast, a DSX allows operators to simplyremove and replace a small wire on its cross-connect field to reroute circuits. This quickresolution is critical for maintaining service evenduring massive redesigns.
IntroductionCoecig wih yor nework
7/31/2019 103253 Be
7/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
3T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Easier reconfiguration allows operators tomanage the subsequent traffic flow whenaccess to the physical network layer isrequired. Technicians can simply patch into thecorresponding circuits with a patch cord forreconfiguration or monitoring purposes.
Central Termination PointDrig ework eeme rearragemes, aDSX ca maage a reroig, ermiaig,ad maieace cios rom a ceraizedlocation. Without this centralized terminationpoint, as in direct connection, cables mustbe pulled from each network element andsubsequently rerouted to new destinations.Cabes soo ier he cera oice; racigbecomes difficult; and labor costs soar. Miningfor the physical facilities on the backplaneof a network element is cramped and time-cosmig. this mehod o hardwirigjeopardizes reliability and often results ininterrupted service because damage isnt limitedto individual circuits but effects can quickly spreadto all circuits within a shared component likea common electronic backplane. For instance,a dropped wrench could knock out an entirenetwork element, inducing havoc throughouthe ework.
DSX and interconnect systems allow operatorso do a maieace ad reroig rom oelocation. These robust devices protect other, moredelicate equipment from inadvertent damageduring the circuit rearrangement process. Andwih eas circi ideiicaio ceraized, wirigon network elements backplanes remainsdisrbed ad harmed.
Circuit AccessA networks success often depends on howquickly it adapts to change and the simplicity ofits maintenance capabilities. Networks require
physical access points on every circuit formonitoring, patching, and testing purposes. Theability to tap into and read the signal on anycircuitand not interrupt service to customersisinvaluable in todays market. By incorporatingjacks, DSX is the only solution that can localizea fault by allowing operators complete access toa circi, aime.
Passing a signal through a jack creates awidow io he circi. throgh his widowthe signal can be monitored or pulled out, ora new signal can be introduced, by placing atemporary patch cord into the correspondingports. By inserting one end of the patch cord intoa monitor port on the DSX, and the other endinto a test unit or other device, operators canmonitor a signal without interrupting service.
When intrusive testing is required, operatorssimply plug the patch cord into the IN/OUT porto he cross-coec ied o he DSX. the sigaflow to the cross-connect field is interrupted anda new connection between the jack and patchca be made. the siga ca he be se o atesting device to check for transmission errorsor to another network element to temporarilyreroe he siga.
the iegraio o a DSX io he ework aowsoperators to patch around faulty circuits quicklyand easily. And operators are given time torestore the primary circuit without fear of serviceoages or csomers.
Passing the Test of TimeNetworks evolve over time as technology changesand advanced services are adopted. Equipmentobsolescence and the necessary incorporation
of new technologies present carriers with on-going challenges. When the customers and themarket are ready, the carrier must move quicklyor risk missing revenue opportunity. A DSX cross-connect point allows deferment of property/plantand equipment expenses and allows upgradesto new technologies with the least disruption tocurrent services. A physical plant with optimalcable management capabilities encourages quickreconfigurations, upgrades, and diverse alternaterouting. And only through the cross-connectionof network elements will service providers be ableo mee he chagig eeds o heir eworks.
IntroductionCoecig wih yor nework
7/31/2019 103253 Be
8/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
4T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
IntroductionBantam Jack Technology Features
Mult. to - 48V Mult. to - 48V
Mult. to Shield GndMult. to Gnd
Mult. to Shield GndMult. to Gnd
Mult. to - 48V
Mult. to Shield GndMult. to Gnd
Jackfield JackfieldTL TL
R2 R2
R2 = 430 ohms
MONMON
T
R
T
R
OUT OUT
OUT
OUTOUT
IN
OUT
ININ
ININ
IN
OUT
OUT
IN
IN
T
RT
R
TRT
R
TRT
R
IN/OUTPins
IN/OUTPins
OUT
IN
TRTR
IN/OUTPins
DigitalSwitch
Cross-Connects Cross-Connects
Cross-Connects
TRACER
T
RT
R
TRACER
Bantam Patch Cords
R
T
JackfieldTL
R2MON
T
R
OUT
IN
OUT
OUT
IN
IN
T
R
T
R
TRACER
Semi-Permanent
Connections(Cross-Connect)
Temporary Patch ConnectionsSupercede Semi-Permanent
Connections at Cross-Connects
ToOfficeRepeater A
TypicalCross-connect
TypicalPatch
ToOfficeRepeater B
R
T
R
T
In order to understand how a DSX performscross-connect and patching functions, it is bestto study its key component, the jack, shown inhe igre beow.
Typical Cross-Connect
Network digital equipment (NE) have twoconnection points where the digital signal canenter and exit the equipment. Each DSX jackis coeced o a sige nE b coecig heOUT pins to the signal exiting the NE and theIN pins to the signal entering the NE. Whenone jack is connected to each NE, test and accessfunctions can be performed.
Typical Patch or CircuitRearrageme
In order to temporarily patch or reroute a circuit,he digia siga rom oe nE is roed hrogha designated normally closed jack (one IN andone OUT jack per NE) to a pair of jacks onanother NE. The circuit is completed by cross-connecting the OUT of one jack; i.e., digitalswitch, to the IN on the other jack; i.e., officerepeater. Likewise, the IN on the first jack iscross-connected to the OUT of the second jack,hs ormig a iercoecio bewee he wojacks and therefore between the two NEs.
DSX Jack Schematic Illustrating Cross-Connect and Patching Functions
7/31/2019 103253 Be
9/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
5T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
IntroductionPanel Configuration Features
Cross-connect panels are available in a variety of cross-connect formats, circuit densities and labelingoptions. The following examples highlight standard product options:
RearCross-ConnectRear cross-connect panels feature jacks on thefront of the panel. Equipment cable interfacesad cross-coec ieraces are ocaed o herear of the panel.
Front (Split)Cross-ConnectFront (split) cross-connect panels feature bothjacks and cross-connect interfaces on the front ofthe panel. Half of the cross-connects are on theleft side of the jacks, half are on the right side.Equipment cable interfaces are located on therear of the panel.
Front (Below)Cross-ConnectFront (below) cross-connect panels feature bothjacks and cross-connect interfaces on the front ofthe panel. The entire cross-connect field is locatedbelow the jacks. Equipment cable interfaces arelocated on the rear of the panel.
Total Front AccessCross-ConnectTotal front access panels feature all interfaces onthe front of the panel. Cross-connect interfacesare on either side of the jacks and equipmentcable interfaces are located below the jacks.
7/31/2019 103253 Be
10/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
6T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
IntroductionSkeleton Bay Lineup Features
A typical DSX system consists of two or morebays joined together to form a DSX bay lineup.A lineup can be designed for either rear or frontcross-connect configurations. Both configurationsse he same basic skeeo ba ramework,which supports the DSX panels and auxiliaryequipment and includes integrated cablemaageme.
Lineup Design and Requirements
The cross-connect lineup illustration belowshows the increased density achieved in a lineupsig DSXi panels. Up to 5,880 circuits can bemanaged in a five-bay lineup, compared to the
traditional 4,620 circuits. This maximizes valuablefloor space, while still providing proper cablemanagement to support high volumes of cross-connect jumpers. A complete DSX lineupconsists of:
Integrated cable management on each bay,which provides all the necessary hardware tosafely and easily route equipment cables andcross-connect jumpers throughout a lineup.When additional bays are needed in a network,existing jumpers can remain intact whileaddiioa cabig is roed ad recoigred.Properly designed cable management is critical
i maiaiig ework iegri ad aowigunimpeded growth.
Rack filler panels between bays, which allowroom for routing equipment cables into eachbay. Spacing also provides room for jumperrings placed on the bay for control of verticaljumper routing. The spacer width betweenbas is deermied b he mber o DSXterminations per bay and the type of cablingused. Notice that a rack filler panel is providedat the growth end of the lineup and is readyfor the next bay addition.
End guard panels at the end of bay lineups,which protect cables routed in the duct areaand provide a location for bay alarm indicatorsand AC light switches.
A maintenance bay is typically designated
as every third or fourth bay within a DSXlineup. In addition to DSX panels, auxiliaryor maintenance equipment such asbridging office repeaters, interbay panels,communication panels, equipment shelvesfor portable test sets, and pencil andstorage drawers are placed in this bay. Thesemaieace bas aow oice echicias omaintain digital services efficiently.
Cross aisle panels, which should be placed inthe top position of each bay in multiple lineupsystems, to extend cross-connections safely toother lineups. A cross aisle panel is connectedto an adjacent cross aisle panel in anotherlineup by permanent tie cables.
Growth
Panel #14Panel #13Panel #12
Panel #10Panel #9Panel #8Panel #7
Panel #6
Panel #5
Panel #5
Panel #4
Panel #3
Panel #2Panel #1
2.13 m (7') End Guard2.13 m x 63.5mm(7' X 2.5") RackFiller Panel
2.13 m x 190.5 mm(7' X 7.5") Rack Filler Panel
2.13 m (7') End Guard(Move to End of Line Upwith Addition of Each New Bay)
190.5 mm(7.5")
Reserve PanelPanel #14Panel #13Panel #12Panel #10Panel #9Panel #8Panel #7
Panel #6
Panel #5
Panel #5
Panel #4
Panel #3
Panel #2Panel #1
Reserve Panel
Panel #14Panel #13Panel #12Panel #10Panel #9Panel #8Panel #7
Panel #6
Panel #5
Panel #5
Panel #4
Panel #3
Panel #2Panel #1
Reserve Panel
Panel #14Panel #13Panel #12
Panel #10Panel #9Panel #8Panel #7
Panel #6
Panel #5
Panel #5
Panel #4
Panel #3
Panel #2Panel #1
Reserve Panel
660 mm(26")
63.5 mm (2.5")
RearJumper Trough
Fuse Panel
RearJumper Trough
Fuse Panel
RearJumper Trough
Fuse Panel
RearJumper Trough
Fuse Panel
RearJumper Trough
RearJumper Trough
RearJumper Trough
RearJumper Trough
63.5 mm(2.5")
63.5 mm(2.5")
660 mm(26")
660 mm(26")
190.5 mm(7.5")
190.5 mm(7.5")
Typical DSX Lineup Expansion
7/31/2019 103253 Be
11/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
7T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
IntroductionSkeleton Bay Lineup Features
As the central part of the DSX lineup, eachskeleton bay provides preassembled cablemaageme ad he basic ramework o secresupport valuable network equipment and alloweicie ad orgaized cabe roig. Paes adchassis are selected and installed separately forsystem customization and flexible growth. Baysare also available fully loaded with preinstalledDSX panels. Each skeleton bay is preconfigured foreither front or rear cross-connect applications.
DSX bays are available in a 15-inch footprintdepth. This provides additional jumper capacityfor lineups with greater growth potential.The additional 3 inches of depth provides over50 percent additional capacity in the upper andlower jumper troughs. The bays are available in19- or 23-inch mounting widths. Each skeletonbay includes:
Integrated cable management, which providesa he ecessar hardware o sae roeequipment cables and cross-connect jumpersthroughout the bay. When a panel needsto be added, existing jumpers can remainiac whie addiioa cabig is roed adreconfigured. Extra large vertical jumper ringsensure routing is never restricted and supporthigh volumes of cross-connect jumpers. Jumpertroughs placed at the top and bottom of each
bay route jumpers horizontally between bays.this coios horizoa wirewa assresa obockig ssem where a wo circismay be cross-connected. Whereas permanentequipment cabling is tied into place, thesemi-permanent cross-connect jumpers are not,but rather float in the vertical and horizontalwirewas ad ma be reroed as he eworkchanges over time. Cable tie brackets attachedto the side of the rack provide a means tosecure NE equipment cabling and keep themneatly separated from jumpers.
Network unequal flange-type racks provideefficient vertical cable ducts for NE equipmentcabling. The typical rack height is 7 feet toallow technician access to circuits and jackswiho he eed or adders. Coigraiosover 7 feet are available upon request.
Fuse panels, which are preinstalled inthe uppermost part of the bay, belowhorizoa wirewas.
Guard boxes, which provide a bumper atthe base of the bay to prevent maintenanceequipment from hitting bay equipment panels.
Additional equipment recommended:
AC raceways and outlets, which are placedon the guard boxes and provide space foreecrica wirig. the are recommededon every third or fourth bay and areordered separately.
Rack installation kits, which provide hardwareto anchor the rack to the floor and support thetop of the rack to superstructure above. Kits forboth concrete and computer floors are availableand are ordered separately.
7/31/2019 103253 Be
12/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
8T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
IntroductionProduct Family Features
ADC KRONE offers many varieties of DS1 products to ensure that the right features are available foryour specific cross-connect or interconnect needs. From the fixed-circuit DSXi panels to the modularFlexDSX panels, all DS1 panels are proven performers that have set the industry standard. The modularsystems minimize initial network costs by growing the network as customer demand increases. All arebacked by ADC KRONEs quality manufacturing and dedicated sales and service team to help keepeworks rig smooh.
FeatureDSXi
PanelsFlexDSXPanels
ModularBantamPanels
InterconnectPanels
Front Cross-ConnectRear Cross-Coec
Fixed-Circuit Panels
Modular ChassisRemovable JacksSingle Monitor Jack (3 ports)Dual Monitor Jacks (4 ports)In-Service PatchingAbility to Prewire Backplanewithout Jacks
tracer lEDsDesigaio labes
WECO/EIA Mounting
Maximum Circuits Per Panel 84 84 112 84
Product Family Comparison
7/31/2019 103253 Be
13/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
9T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi FamilyIrodcio Desig Eemes
ADC KRONEs DSXi product family is the next generation of panels for digital signal cross-connect in T1eworks. DSXipanels have improved density and manageabilitymaking this the preferred choice infixed-circuit DSX-1 equipment.
Features
Increased density
Up to 27 percent greater bay density, saving
valuable floor space.
Innovative design
Easier circi access ad aser ideiicaio o
help save time and money.
Ingenious cable management
Ensures cables are kept well organized.
Incredibly reliable panels
Designed to comply with NEBS Level 3 standards
ad backed b a ieime warra.
Brighter LED
Improved designation
Front View
Physical and visual separationsbetween monitor and IN/OUT ports
Icreased desiSeek, ergoomic desig
Smaer, brigher lEDs
Every circuit is numbered,wih ke circis boded
Conveniently locatedcaaog mber
large circi ideicaio cards
Plenty of labeling space
Rear View
Jumper rings for maximum cablemaageme Wire-wrap connections
Circi desigaio abe
7/31/2019 103253 Be
14/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
10T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi Family84-termiaio Rear Cross-Coec Paes
Features
Improved circuit density by 20 percent with
4-inch-high panels
Two 4-inch by 4-inch vertical jumper rings
WECO/EIA mounting brackets
Circuit identification cards with major
circis boded
Red tracer LEDs for easier circuit identification
Panel color: putty
Di-G2CU1(Front View)
Di-G2CU1(Rear view)
Cross-
Connect
IN/OUT
Cabling Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Rear Wire-wrap 1-28 A
1-28 B
1-28 C
102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-G2GU1
Rear Wire-wrap 1-84 102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-G2CU1
Rear 64-pin 1-28 A
1-28 B
1-28 C
102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-G3GU1
Rear 64-pin 1-84 102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-G3CU1
Rear Wire-wrap 1-28 A
1-28 B
1-28 C
178 mm x 483 mm x 203 mm
(7" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-F2GU1*
Rear Wire-wrap 1-84 178 mm x 483 mm x 203 mm
(7" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-F2CU1*
*Accommodates 19" or 23" rack mount.
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
15/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
11T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi Family64-termiaio Rear Cross-Coec Paes
Features
Two 4-inch by 4-inch vertical jumper rings
Circuit identification cards with majorcircis boded
WECO/EIA mounting brackets
Red racer lEDs or easier circi ideiicaio
Panel color: putty
Cross-
Connect
IN/OUT
Cabling Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Rear Wire-wrap 1-32 A
1-32 B
102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-D2GU1*
Rear Wire-wrap 1-64 102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-D2CU1*
*Accommodates 19" or 23" rack mount.
Di-D2CU1(Front View)
Di-D2CU1(Rear view)
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
16/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
12T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi Family56-Termination Rear Cross-Connect Panels
Cross-Connect
IN/OUTCabling Designation
Dimensions(HxWxD)
MountingOptions
CatalogNumber
Rear Wire-wrap 1-28 A
1-28 B
102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-A2GU1*
Rear Wire-wrap 1-56 102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-A2CU1*
Rear 64-pin 1-28 A
1-28 B
102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-A3GU1*
Rear 64-pin 1-56 102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-A3CU1*
*Accommodates 19" or 23" rack mount.
Features
Two 4-inch by 4-inch vertical jumper rings
Circuit identification cards with major
circis boded
WECO/EIA mounting brackets
Red tracer LEDs for easier circuit identification
Panel color: putty
Di-A2GU1(Front View)
Di-A2GU1(Rear view)
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
17/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
13T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi Family84-Termination Front Cross-Connect Panels
Features
Increased circuit density by 14 percent with6-inch-high panels
Two 2-inch by 4-inch vertical jumper rings
Circuit identification cards with majorcircis boded
WECO/EIA mounting brackets
Red tracer LEDs for easier circuit identification
Front cross-connect and network equipmentcabe ierace
Panel color: putty
Cross-
Connect
IN/OUT
Cabling Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Front
(split)
Wire-wrap 1-28 A
1-28 B
1-28 C
102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-M2GU1
Front
(split)
Wire-wrap 1-84 102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-M2CU1
Front
(split)
64-pin 1-28 A
1-28 B1-28 C
102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm(2", 3", 4") recess
Di-M3GU1
Front
(split)
64-pin 1-84 102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-M3CU1
Front
(beow)
Wire-wrap 1-28 A
1-28 B
1-28 C
178 mm x 483 mm x 203 mm
(7" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-T2GU1*
Front
(beow)
Wire-wrap 1-84 178 mm x 483 mm x 203 mm
(7" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-T2CU1*
*Accommodates 19" and 23" rack mount.
Di-M2GU1(Front View)
Di-M2GU1(Rear view)
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
18/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
14T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi Family64-Termination Front Cross-Connect Panels
Cross-Connect
IN/OUTCabling Designation
Dimensions(HxWxD)
MountingOptions
CatalogNumber
Front
(split)
Wire-wrap 1-32 A
1-32 B
102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-K2GU1
Front
(split)
Wire-wrap 1-64 102 mm x 582 mm x 203 mm
(4" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-K2CU1
Front
(beow)
Wire-wrap 1-32 A
1-32 B
152 mm x 483 mm x 203 mm
(6" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-R2GU1*
Front(beow)
Wire-wrap 1-64 152 mm x 483 mm x 203 mm(6" x 19" x 8")
Flush,51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-R2CU1*
Features
Increased circuit density by 20 percent with
4-inch-high panels
Two 2-inch by 4-inch vertical jumper rings
Circuit identification cards with majorcircis boded
WECO/EIA mounting brackets
Red tracer LEDs for easier circuit identification
Panel color: putty
*Accommodates 19" and 23" rack mount.
Di-K2GU1(Front View)
Di-K2GU1(Rear view)
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
19/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
15T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi Family56-Termination Front Cross-Connect Panels
Cross-Connect
IN/OUTCabling Designation
Dimensions(HxWxD)
MountingOptions
CatalogNumber
Front
(split)
Wire-wrap 1-28 A
1-28 B
102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-H2GU1*
Front
(split)
Wire-wrap 1-56 102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-H2CU1*
Front
(split)
64-pin 1-28 A
1-28 B
102 mm x 483 mm x 203 mm
(4" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-H3GU1*
Front(split)
64-pin 1-56 102 mm x 483 mm x 203 mm(4" x 19" x 8")
Flush,51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-H3CU1*
Front
(beow)
Wire-wrap 1-28 A
1-28 B
152 mm x 483 mm x 203 mm
(6" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-N2GU1*
Front
(beow)
Wire-wrap 1-56 152 mm x 483 mm x 203 mm
(6" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-N2CU1*
Front
(beow)
64-pin 1-28 A
1-28 B
152 mm x 483 mm x 203 mm
(6" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-N3GU1*
Front(beow)
64-pin 1-56 152 mm x 483 mm x 203 mm(6" x 19" x 8")
Flush,51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-N3CU1*
*Accommodates 19" and 23" rack mount.
Features
Improved circuit density by 14 percent with
6-inch-high panels
Two 2-inch by 4-inch vertical jumper rings
Circuit identification cards with majorcircis boded
WECO/EIA mounting brackets
Red tracer LEDs for easier circuit identification
Panel color: puttyDi-H2GU1(Rear view)
O r d e r i n g I n f o r m a t i o n
Di-H2GU1 V:-42/-56VDC A:2A MAX.
Di-H2GU1(Front View)
7/31/2019 103253 Be
20/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
16T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi Family84-Termination Total Front Access Cross-Connect Panels
Cross-
Connect
IN/OUT
Cabling Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
toa
ro
access
Wire-wrap 1-28 A
1-28 B
1-28 C
152 mm x 582 mm x 203 mm
(6" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-X2GU1
toa
ro
access
Wire-wrap 1-84 152 mm x 582 mm x 203 mm
(6" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-X2CU1
Features
Increased circuit density by 14 percent with6-inch-high panels
Two 2-inch by 4-inch vertical jumper rings
Circuit identification cards with majorcircis boded
WECO/EIA mounting brackets
Red tracer LEDs for easier circuit identification
Front cross-connect and network equipmentcabe ierace
Panel color: putty
O r d e r i n g I n f o r m a t i o n
Di-X2CU1(Front View)
7/31/2019 103253 Be
21/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
17T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Cross-
Connect
IN/OUT
Cabling Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
toa
ro
access
Wire-wrap 1-32 A
1-32 B
152 mm x 582 mm x 203 mm
(6" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-W2GU1
toa
ro
access
Wire-wrap 1-64 152 mm x 582 mm x 203 mm
(6" x 23" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-W2CU1
DSXi Family64-Termination Total Front Access Cross-Connect Panels
Features
Two 2-inch by 4-inch vertical jumper rings
Circuit identification cards with majorcircis boded
WECO/EIA mounting brackets
Red tracer LEDs for easier circuit identification
Front cross-connect and network equipmentcabe ierace
Panel color: putty
Di-W2GU1(Front View)
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
22/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
18T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi Family56-Termination Total Front Access Cross-Connect Panels
Features
Two 2-inch by 4-inch vertical jumper rings
Circuit identification cards with majorcircis boded
WECO/EIA mounting brackets
Red tracer LEDs for easier circuit identification
Front cross-connect and network equipmentcabe ierace
Panel color: putty
Cross-Connect
IN/OUTCabling Designation
Dimensions(HxWxD)
MountingOptions
CatalogNumber
toa
ro
access
Wire-wrap 1-28 A
1-28 B
152 mm x 483 mm x 203 mm
(6" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-U2GU1*
toa
ro
access
Wire-wrap 1-56 152 mm x 483 mm x 203 mm
(6" x 19" x 8")
Flush,
51 mm, 76 mm, 102 mm
(2", 3", 4") recess
Di-U2CU1*
*Accommodates 19" and 23" rack mount.
Di-U2GU1(Front View)
Di-U2GU1(Rear view)
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
23/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
19T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Features
Accommodates rear cross-connect styleDSXi panels
Increased density with up to 1,176terminations in a 23-inch bay
WECO network-style racks
Equipped with fuse panel, upper and lowerhorizontal jumper troughs, and vertical
jumper rings
Bay color: putty
DSXi FamilyRear Cross-Connect Skeleton Bays
DMB-77WC01(Front View) (Side view)
2.14 m(7')
1
5
10
15
20
25
30
35
RESERVE FOR
MISCELLANEOUS APPLICATION
658 mm(25.9")
381 mm(15")
Footprint
T
127 mm (5")Wide Channel
Description
Dimensions
(HxWxD)
Catalog
Number19" bay
Rear cross-connect skeleton bay, empty
Accommodates up to (14) 102 mm (4") high
56-termination panels, 784 terminations
2.14 m x 483 mm x 381 mm
(7' x 19" x 15")
DMB-77WC02
23" bays
Rear cross-connect skeleton bay, empty
Accommodates up to (14) 102 mm (4") high
84-termination panels, 1,176 terminations
2.14 m x 584 mm x 381 mm
(7' x 23" x 15")
DMB-77WC01
Rear cross-coec ba, oaded wih
14 Di-G2GU1 panels
2.14 m x 584 mm x 381 mm
(7' x 23" x 15")
DMB-72WC02
Rear cross-coec ba, oaded wih
14 Di-G2CU1 panels
2.14 m x 584 mm x 381 mm
(7' x 23" x 15")
DMB-72WC01
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
24/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
20T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi FamilyFront Cross-Connect Skeleton Bays
Features
Accommodates front cross-connect styleDSXi panels
Increased density with up to 784 terminationsin a single 19-inch bay; 1,176 terminations in
a 23-inch bay
WECO network-style racks
Equipped with fuse panel, upper and lower
horizontal jumper troughs, and vertical
jumper rings
Bay color: putty
Description
Dimensions
(HxWxD)
Catalog
Number
19" bay
Front cross-connect skeleton bay, emptyAccommodates up to (14) 102 mm (4") high
56-termination panels, 784 terminations
2.14 m x 483 mm x 381 mm(7' x 19" x 15")
DMB-78WC02
23" bays
Front cross-connect skeleton bay, empty
Accommodates up to (14) 102 mm (4") high
84-termination panels, 1,176 terminations
2.14 m x 584 mm x 381 mm
(7' x 23" x 15")
DMB-78WC01
Front cross-connect bay, f oaded wih
14 Di-M2GU1 panels
2.14 m x 584 mm x 381 mm
(7' x 23" x 15")
DMB-71WC02
Front cross-connect bay, f oaded wih
14 Di-M2CU1 panels
2.14 m x 584 mm x 381 mm
(7' x 23" x 15")
DMB-71WC01
DMB-78WC01(Front View)
2.14 m(7')
658 mm(25.9")
381 mm(15")
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
25/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
21T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi FamilyRack Hardware
127 mm(5")
381 mm(15")
2.14 m(7')
2.14 m(7')
381 mm(15")
64 mm(2.5")
Universal End Guard Panel(RAC-7B0162)
Rack Filler Panel(RAC-7C0545)
Note: color is putty.
Description
Dimensions
(HxW)
381 mm (15")Deep System
Catalog Number
Rack iller panel
Closed guard box for concrete floors
equipment cables enter from overhead
2.14 m x 64 mm (7' x 2.5") RAC-7C0539
2.14 m x 120 mm (7' x 5") RAC-7C0545
2.14 m x 191 mm (7' x 7.5") RAC-7C0810
2.14 m x 254 mm (7' x 10") RAC-7C0551
Open guard box for raised floors
equipment cables enter from below2.14 m x 64 mm (7' x 2.5") RAC-7C0633
2.14 m x 120 mm (7' x 5") RAC-7C0639
2.14 m x 191 mm (7' x 7.5") RAC-7C0811
2.14 m x 254 mm (7' x 10") RAC-7C0645
Universal end guard panel 2.14 m (7') RAC-7B0162
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
26/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
22T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
DSXi FamilyRack Hardware
AC Raceway with Outlet(ACOK-PWNB)
Description Dimensions (HxW) Catalog Number
AC raceway
With outlet (2 per rack where outlets are required) ACOK-PWNB
Without outlet (2 per rack where outlets are not required) ACB-PWNB
AC raceway iller
64 mm (2.5"); (2 per 2.5" filler panel) AC-PWNB-RS2.5
127 mm (5"); (2 per 5" filler panel) AC-PWNB-RS5
254 mm (10"); (2 per 10" filler panel) AC-PWNB-RS10
Blank panels
WECO 51 mm x 584 mm (2" x 23") PWBP-2023
102 mm x 584 mm (4" x 23") PWBP-4023
152 mm x 584 mm (6" x 23") PWBP-6023
203 mm x 584 mm (8" x 23") PWBP-8023
EIA 45 mm x 584 mm (1.75" x 23") PWBP-1723
89 mm x 584 mm (3.5" x 23") PWBP-3523
133 mm x 584 mm (5.25" x 23") PWBP-5223
178 mm x 584 mm (7" x 23") PWBP-7023
Rack installation kits
Concrete loor rack installation kit;or sewithoverhead cable racking
2.14 m (7') network rack kit includes:(1) floor mounting kit(1) top attachment kit for 7' rack(12) rack tie bracket kits(1) rack grounding kit
RINST-DSX7-PW
Raised loor rack installation kit (zone 4 rated);or se withoutoverhead cable racking
2.14 m (7') network rack kit includes:(1) raised floor mounting kit(12) rack tie bracket kits(1) rack grounding kit
RINST-DSXRFL-PW
Note: color is putty.
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
27/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
23T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Jack Mount and Rear Interface Assembly
-48V
RET
SG
Power
Even Jack Card
CrossConnect
MON IN
IN
OUT
MON OUT
Tracer
Lamp
Equipment
T
T
R
ROUT
IN
TL
T
R
T
RIN
OUT
-48V
TL
RET
R
T
SG
RO
XRO
XTO
TO
TI
XTI
XRI
RI
-48V
TL
RET
R
T
SG
RO
XRO
XTO
TO
TI
XTI
XRI
RI
T
R
T
R
Front
Rear
-48V
TL
RET
R
T
RO
XRO
XTO
TO
TI
XTI
XRI
RI
SG
-48V
TL
RET
R
T
RO
XRO
XTO
TO
TI
XTI
XRI
RI
SG
T
R
T
R
-48V
RET
SGPower
Cross
Connect
MON IN
IN
OUT
MON OUT
TracerLamp
Equipment
T
T
R
ROUT
IN
TL
T
R
T
R
OUT
IN
Jack Mount and Rear Interface AssemblyOdd Jack Card
Front
Rear
FlexDSX FamilyIrodcio Desig Eemes
Features
Four-port jack cardsDual monitor ports enable circuit monitoring in bothdirecios
Staggered jack alignment
Supports industry-standard patch cords
Up to 84 circuits in a 6-inch-high chassis
Icreased ba desi
Integrated cable management
Jumper rings and rear cable bars are installed on theskeeo ba
IN/OUT cable terminations on the backplane
Provides multiple circuit count configurations -
84, 64 and 56
Four-Port Jack Card
The four-port jack card features dual monitorports, allowing the signal to be monitoredin both directions from a single access point.Staggered even/odd jacks allow industry-standard patch cords to be used.
Monitoring or testing the circuit in bothdirections from a single location simplifiestroubleshooting and saves technician time.
Access to both ends of the circuit is critical,especially when the other end of thecross-coec is ess accessibe, sch as icollocation applications.
FlexDSX chassis accommodate four-port jackcards with dual monitor ports. Using thesedual monitor ports, technicians save timeb moiorig boh sides o a circi rom asingle test access point.
The modular FlexDSX components consistof the dual monitor jack, four-pack moduleand the chassis. The jack card slides into thefour-pack module that includes the wire-wrap IN/OUT equipment cable terminationthat creates the backplane. Staggered jacksmaximize density so that industry-standardpatch cords are used. The FlexDSX modularsystem provides multiple circuit counts of 84,64 and 56.
Even Jack Card Assembly
Odd Jack Card Assembly
Four-Port Jack Card
7/31/2019 103253 Be
28/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
24T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
FlexDSX FamilyIrodcio Desig Eemes
Chassis
The FlexDSX chassis is loaded with four-packmodes. the oaded chassis ssemsimplifies ordering and minimizes expense.
Skeleton Bay
The skeleton bay holds up to ten FlexDSXchassis with one panel position reserved formiscellaneous applications. The bay is equippedwith fuse panel, jumper rings, troughs andrear cable tie-down bars for superior cablemaageme.
Four-Pack Module
FlexDSX Chassis
FlexDSX Skeleton Bay
Four-Pack ModuleFlexDSX four-pack module contains fourindividual jack cards. IN/OUT equipment cableterminations on the backplane maximize flexibility.
7/31/2019 103253 Be
29/76
7/31/2019 103253 Be
30/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
26T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Features
All chassis are fully loaded with four-port
jack cards
Circuit identification labels
Two 4-inch by 5-inch vertical jumper rings
Tracer LEDs for fast circuit identification
Chassis color: putty
FlexDSX Family84-Termination Front Cross-Connect Panels
DFX-100084(Front View)
Cross-Connect Terminations Designation
Dimensions
(HxWxD)MountingOptions
Catalog
Number
Front 84 1-84 152 mm x 582 mm x 152 mm
(6" x 23" x 6")
Flush DFX-100084
Components of FlexDSX System
Empty chassis
4-pack with jacks
84-Termination Panel
DFX-9T0001
DFX-9T1000
O r d e r i n g I n f o r m a t i o n
DFX-100084(Rear view)
7/31/2019 103253 Be
31/76
7/31/2019 103253 Be
32/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
28T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Cross-Connect Terminations Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
Front 56 1-56 152 mm x 483 mm x 152 mm(6" x 19" x 6")
Flush DFX-100056*
*Accommodates 19" and 23" rack mount.
Features
All chassis are fully loaded with four-port
jack cards
Circuit identification labels
Two 4-inch by 5-inch vertical jumper rings
Tracer LEDs for fast circuit identification
Chassis color: putty
FlexDSX Family56-Termination Front Cross-Connect Panels
DFX-100056(Front View)
Components of FlexDSX System
Empty chassis
4-pack with jacks
56-Termination Panel
DFX-9T0004
DFX-9T1000
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
33/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
29T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
305 mm(12")
Footprint
2.14 m(7')
114 mm(4.50")
127 mm (5") WideChannel
1
5
10
15
20
25
30
35
39
Position 1
Position 2
Position 3
Position 4
Position 5
Position 6
Position 7
Position 8
Position 9
Position 10
Cable Tie BarsLowerCable
Trough
Upper CableTrough
51 mm (2")Stand-Off
Bracket
Rack GroundPost Terminal
Cable RingWelded On TroughTo SupportCrossing CablesBetween Bays
Rear Cable SupportBars Are ProvidedFor IN/OUT Cable
Tie Down
Front Wiring DuctsAre Provided ToManage AndSupport Cross-Connect Cabling
Power WireBracket
658 mm(25.9")
FlexDSX FamilyFront or Rear Cross-Connect Skeleton Bays
FlexDSX skeeo bas ca be ordered i roor rear cross-coec coigraios wih a heecessar cabe maageme isaed, b wihno chassis. This allows DSX equipment to beeasi added as eeded o csomize eworksand provide flexible growth. The bays can also beordered preassembled with chassis for fast andeasy installation. Preinstalled cable and jumpermanagement ensures that existing jumpers neednever be touched when chassis are added to thebay, and jumper routing is never restricted.
Features
Accommodates both the front and rear
cross-connect style FlexDSX chassis
23-inch WECO network-style rack
Equipped with fuse panel, upper and lowerhorizontal jumper troughs, and vertical
jumper rings
Bay color: putty
DescriptionDimensions
(HxWxD)CatalogNumber
23" bays
Front cross-connect skeleton bay, emptyAcccomodates up to (10) 152 mm (6") high chassis;840 ermiaios
2.14 m x 584 mm x 305 mm
(7' x 23" x 12")
DFX-B7S001
Front cross-connect bay, fully loaded with10 DFX-100084 panels
2.14 m x 584 mm x 305 mm
(7' x 23" x 12")
DFX-B7C002
Rear cross-connect skeleton bay, emptyAccommodates up to (14) 102 mm (4") high,84-termination panels, 1,176 terminations
2.14 m x 584 mm x 381 mm
(7' x 23" x 15")
DMB-77WC01
DFX-B7S001(Side view)
O r d e r i n g I n f o r m a t i o n
(Front View) (Rear view)
7/31/2019 103253 Be
34/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
30T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
127 cm(5")
305 mm(12")
2.14 m(7')
2.14 m(7')
305 mm(12")
64 mm(2.5")
FlexDSX FamilyRack Hardware
Universal End Guard Panel(UEGP-7PW)
Rack Filler Panel Kit(7RFP-5NPW)
Description
Dimensions
(HxW)
305 mm (12")Deep System
Catalog NumberRack iller panel
Closed guard box for concrete floors
equipment cables enter from overhead
2.14 m x 64 mm (7' x 2.5") 7RFP-25NPW
2.14 m x 120 mm (7' x 5") 7RFP-5NPW
Open guard box for raised floorsequipment cables enter from below
2.14 m x 64 mm (7' x 2.5") RAC-7C0554
2.14 m x 120 mm (7' x 5") RAC-7C0353
Universal end guard panel 2.14 m (7') UEGP-7PW
Note: color is putty.
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
35/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
31T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
FlexDSX FamilyRack Hardware
AC Raceway with Outlet(ACOK-PWNB)
Description Dimensions (HxW) Catalog Number
AC raceway
With outlet (2 per rack where outlets are required) ACOK-PWNB
Without outlet (2 per rack where outlets are not required) ACB-PWNB
AC raceway iller
64 mm (2.5"); (2 per 2.5" filler panel) AC-PWNB-RS2.5
127 mm (5"); (2 per 5" filler panel) AC-PWNB-RS5
254 mm (10"); (2 per 10" filler panel) AC-PWNB-RS10
Blank panels
WECO 51 mm x 584 mm (2" x 23") PWBP-2023
102 mm x 584 mm (4" x 23") PWBP-4023
152 mm x 584 mm (6" x 23") PWBP-6023
203 mm x 584 mm (8" x 23") PWBP-8023
EIA 45 mm x 584 mm (1.75" x 23") PWBP-1723
89 mm x 584 mm (3.5" x 23") PWBP-3523
133 mm x 584 mm (5.25" x 23") PWBP-5223
178 mm x 584 mm (7" x 23") PWBP-7023
Rack installation kits
Concrete loor rack installation kit;or sewithoverhead cable racking
2.14 m (7') network rack kit includes:(1) floor mounting kit(1) top attachment kit for 7' rack(12) rack tie bracket kits(1) rack grounding kit
RINST-DSX7-PW
Raised loor rack installation kit (zone 4 rated);or se without overhead cable racking
2.14 m (7') network rack kit includes:(1) raised floor mounting kit(12) rack tie bracket kits(1) rack grounding kit
RINST-DSXRFL-PW
Note: color is putty.
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
36/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
32T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
FlexDSX FamilySuper High-Density Bay and Rear Cross-Connect System
ADC KRONEs FlexDSX super high-density bay offers greater termination density as well as built-in,trouble-free cable management for flexible network planning, installation and maintenance.
ADC KRONEs FlexDSX super high-density bay design is unmatched in the marketplace. ADC KRONEsvertical IN/OUT terminal blocks with extra cabling space and cable management fanning strips provide50 percent more cabling space than traditional high-density bays. Simultaneously, it provides increasedjumper capacity to simplify cross-connect wire management for easy operation and maintenance. TheFlexDSX super high-density design incorporates a recessed vertical wireway for cross-connect cabling andup to seven horizontal cross-connect jumper wireways instead of the standard two wireways. Verticaland horizontal wireways are on separate planes to avoid congestion and pile up at intersections.
The FlexDSX super high-density bay enables service providers to realize additional cost savings byconserving valuable floor space. The bay provides more than 30% floor space savings, while doublingthe density and provides dual monitoring with ADC KRONEs reliable FlexDSX jack technology.
The FlexDSX super high-density bay achieves greater density in a 7' height x 26" width x 18.75" depth,accommodating up to 1512 (7') usable DSX jack terminations. ADC KRONEs flexible ordering guide
allows bay designs in 64 or 84 jacks per panel. This eliminates jack waste or complications in circuitmaageme admiisraio.
Cross-connect block design provides clear identication of each circuit by offering expanded labeling spaceimproving network documentation and decreasing potential mistakes while troubleshooting
Colored cross-connect labels allow for easy determination of circuit terminations
Flashing LED and dual monitoring In/Out block's design provides better cable management andmore space for cables
Cable entry is allowed on both sides of block
Features
Quick to install
Easy to manage and maintain
Maximizes the termination density of the network
Simplifies engineering
Matches service provider applications
Trouble-free cable management
ADC KRONE reliable DSX jack technology
7/31/2019 103253 Be
37/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
33T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Description
Jacks Per
Panel
# o
Terminations
# o Tie Pair
Circuits
Catalog
Number
Concentration bays, 2.14 m (7')
Overhead cabling 84 1512 160 DFX-SHD001
Raised oor cabig 84 1512 160 DFX-SHD002
Maintenance bays, 2.14 m (7')
Overhead cabling 84 1344 160 DFX-SHD003*
Raised oor cabig 84 1344 160 DFX-SHD004*
Overhead cabling denotes the cable enters the top of the bay and the equipment termination blocks are at the topo he ba. Raised foor cabig deoes he cabe eers rom he raised foor io he boom o he ba ad heequipment blocks are at the bottom of the bay.
*Maintenance bays are equipped with one 56-position interbay panel.
FlexDSX FamilySuper High-Density Bay and Rear Cross-Connect System
O r d e r i n g I n f o r m a t i o n
Features
1512 jacks per 7' bay uses an efficient jack count of84 jacks per panel. Dual monitoring of the out and inports, panel termination count matches digital switching
Broadband equipment for simplified network engineering.Consists of 18 panels of 84 jacks in a single plane.
More than 30% floor space savings the industryshighest DSX density improves profitability by conservingvaluable floor space. Service providers can realize more
revenue and more space for other revenue generatingnetwork equipment.
Incorporating vertical IN/OUT terminal blocks with extracabling space and cable management strips provide 50%more cabling space than traditional high-density bays.
Increased lineup density saves valuable floor space andreduces costs by eliminating the need for bay spacers.Da higed doors wih desigaio abes o boh sides
provide double the designation space. Adhesive backedabes garaee he ideiicaio desigaios wi
always be available. The expanded label space minimizes
the possibility of mistakes during trouble shooting as allcircis are cear ideiied.
Built-in trouble free cross-connect cable managementprovides increased jumper capacity. ADC KRONEs cable
management system eases operations and maintenanceby reducing cross-connect jumper congestion and pileup.
Each standard bay comes with 160 tie pair terminations(two 80-termination wire-wrap blocks). Built-in cross aisle
tie blocks ensure ability to grow new lineups withoutsacrificing overall termination density.
the rear cross-coec high desi desig aows or ajack maintenance activities to remain at an arms length.
Guarantees a worry-free maintenance environment withover 40 years of proven jack quality and reliability and a
lifetime warranty. All components of the bay are made by
ADC KRONE, ensuring quality from beginning to end.
DFX-SHD001(Front View)
7/31/2019 103253 Be
38/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
34T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
FlexDSX FamilySuper High-Density Bay and Rear Cross-Connect System
Description Catalog Number
AC outlet kit; accepts outlet kits in front only, North American ACOK-PWNB
End guards; 2.14 m (7') height x 298 mm (18.75") width SHD-HR-85
Installation kits
Concrete floor, overhead cabling RINST-FLR
Raised oor SHD-HR-91
Raised oor (zoe 4 raed);or se withoutoverhead cable racking
2.14 m (7') network rack kit includes:(1) raised floor mounting kit
(12) rack tie bracket kits(1) rack grounding kit
RINST-DSXRFL-PW
Rack extender; 2.14 m (7') to 3.5 m (11.5') SHD-HR-44n
Accessories
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
39/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
35T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
ADC KRONEs FlexDSX multifunction productsolutions provide maximum flexibility whileeliminating the need to support multiple DS1,DS3, fiber and Ethernet panels, particularlyvaluable in a small to medium size application.
Designed to meet your requirements, oneFlexDSX panel is capable of housing all formsof multimedia services, including fiber, coax, andtwisted pair connectivity. Ultimate flexibility isprovided with the mix and match modularity ofFlexDSX modules.
Attain space savings through FlexDSXs compact,high-density design without compromising es access cioai icdig he damonitor feature of the DS1 and DS3 modules.
The FlexDSX multifunction panel offers theconvenience of complete M13 mux terminationin a single compact 19" W x 5.25" H panel.
Features
Increased modularity
Increased efficiency and flexibility
One panel meets DS1/3, fiber, and Ethernettermination requirements
Interchangeable modules allow
maximum flexibility
- DS1
- DS3
- Fiber terminations
- Ehere modes
Compact size for standard mounting
- 5.25" high EIA
- 6" high WECO
Supports bidirectional testing High-density
- 16 modules in 19" width
- 21 modules in 23" width
Specialty PanelsFlexDSX Multifunction Panel
FlexDSX Multiunction Panel
7/31/2019 103253 Be
40/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
36T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
ADC KRONEs FlexDSX multifunction panel cansupport a variety of module combinations andDS1/3 or fiber handoffs. The DS1 cross-connectprovides four jack cards per module with a dualmoior whie wo ework eeme ermiaioswith bidirectional circuit access are providedby each DS3 interconnect module. The fibertermination module is equipped with six SC-typeadapters. The FlexDSX multifunction panelsmodular design easily adapts to meet a variety ofcsomer eeds.
DS3 Module Fiber ModuleDS1 Module
Specialty PanelsFlexDSX Multifunction Panel
Applications
Wireless cell sites OSP cabinets, CEV or hut
POP
Collocation
CPE
RJ Module
Description Dimensions (HxWxD) Catalog Number
Panels
19" empty panel;16 module capacity
133 mm x 483 mm x 127 mm(5.25" x 19" x 5")
DFX-9E0002
23" empty panel;21 module capacity
152 mm x 584 mm x 152 mm(6" x 23" x 6")
DFX-9T0001
Modules
DS1 module;includes 4 jack cards with dual monitor
1 module width DFX-9T1000
DS3 module MPOP interconnect;includes jacks for 2 network elements (IN/OUT)
1 module width DFX-D3000
Fiber module; includes 6 SC adapters 2 module width DFX-SC0002
RJ Cat 5e Ethernet module;includes 3 Cat 5e RJ45 coupler adapters 1 module width DFX-9RJ002
RJ Cat 6 Ethernet module;includes 3 Cat 6 RJ45 coupler adapters
1 module width DFX-9RJ006
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
41/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
37T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Specialty PanelsModular DS1/DS3 Combination Panel
The modular DSX-1/3 chassis accommodates three 28-termination DS1 modules, threenon-modular 4-termination DS3 modules, a six-position modular DS3 mounting sleeve, or anycombination. The chassis is designed for the outside plant environment and can be installed in
a cabinet, CEV, or hut. The option to include one DS1 module is available or an empty chassis can beordered wih addiioa modes as eeded.
Features
DS1 module features front wire-wrapcross-connects and rear wire-wrap equipmentcabe ierace
DS3 module features rear BNC cross-connectand equipment cable interfaces
Tracer LEDs eliminate manual tracing of cross-coec wires or as circi ideiicaio
Chassis and module color: putty
Chassis with DS1 Modules
* Chassis has three total module positions. One 28-termination module is included. The two additional modules
are ordered separately.
Front View
Rear View
DescriptionCircuitDensity
Dimensions(HxWxD) Catalog Number
Chassis
Chassis with one module; 51 mm,
76 mm, 102 mm (2", 3", 4") recess;
1-14, 15-28 designation
28 178 mm x 584 mm x 229 mm
(7" x 23" x 9")
D1M-1X0012*
Empty chassis 3-position; 51 mm,
76 mm, 102 mm (2", 3", 4") recess
84 DS1
18 DS3
178 mm x 584 mm x 229 mm
(7" x 23" x 9")
DIM1X0027
Modules
DS1 module; mounts into
D1M-1X0012 chassis;
1-14, 15-28 designation
28 D1M-1A0042
DS3 module; mounts into
D1M-1X0012 chassis; 1-4 designation
4 midsize
jacks
D3M-XRMC11
DS3 module; mounts into
D1M-1X0012 chassis; 1-4 designation
4
sadard
size jacks
D3M-XRSC11
6-port midsize module;
mos io DSX4H-6HDSl
1 DS3 DSX-4H-MBRC-BA
Mounting sleeve 6-position; mos
into DIM-1X0027; 1-6 designation
6 DS3 DSX4H-6HDSl
DS1/DS3 combo panel; o-modar;
1-28 ABC, 1-3 designation
84 DS1
3 DS3
178 mm x 584 mm x 203 mm
(7" x 23" x 8")
D1M-1A0060
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
42/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
38T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Rear Access Interconnect Modular SystemIrodcio
Bantam interconnect panels contain pairs ofjacks that are internally cross-connected. Thesepanels utilize the same bantam jacks as the DSX-1 panels, but the internal cross-connection ispermanent. The network elements are connectedtogether when equipment cabling is established.
Application
Interconnect panels are primarily used inapplications where cross-connection is morepermanent. Common applications include DCSierace ad coocaio isaaios.
Interconnect Signal Flow
OUT
OUT
IN
IN
Digital
Interconnect
Network
Element
Network
Element
PermanentEquipment
CablesPermanentEquipment
Cables
Tx OUT
Rx IN
MON
MON
Rx IN
Tx OUT
Digital Interconnect Confguration
To NetworkElement A
To NetworkElement B
PermanentEquipment
Cable
PermanentEquipment Cable
Features
Cost-effective solution for applications wherecircuit reconfiguration is infrequent
Creates permanent, dedicated connectionbewee wo ework eemes o he DSX
ierace
Requires a minimum amount of equipment
and rack space
7/31/2019 103253 Be
43/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
39T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Rear Access Interconnect Modular System56-Termination Interconnect Panel
Features
Chassis is preloaded with 56 individualinterconnect jack cards
Rear wire-wrap IN/OUT cabling
Tracer LEDs eliminate manual tracing of cross-coec wires or as circi ideiicaio
Chassis color: putty
D1M-1E1101(Front View)
D1M-1E1101(Rear view)
Circuit Density
Number o
Terminations
Designation
Dimensions
(HxWxD)
Mounting
Options
Catalog
Number
56 112 1-56 A
1-56 Z
127 mm x 584 mm x 203 mm
(5" x 23" x 8")
Flush D1M-1E1101
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
44/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
40T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Rear Access Interconnect Modular SystemDDP-1 Panels
The digital distribution point (DDP-1) chassis is an interface point placed between a digital cross-connectsystem (DCS) and digital NEs, providing a flexible alternative to hard wiring NEs directly to the DCS.
A digital distribution point provides cable termination and circuit access to digital circuits at the DS1,DS1C, E1 and VT1.5 signal levels. Software cross-connects between two NEs are provided by the DCS.
The DDP-1 chassis is available in a single access configuration. Various circuit densities are available tomatch DCS group quantities; i.e., 56-, 84-circuit. Various wiring connection styles; i.e., wire-wrap, 50-pinor 64-pin connectors and equipment rack styles; i.e., 19-inch, 23-inch mounting are available.
Single-Access Chassis
The single-access chassis allows access to the NE side or the DCS side but not simultaneously. An accesscard is inserted in the normal position (with monitor jack on top) to access the NE. The access card isinserted in the inverted position (monitor jack on bottom) to access the DCS.
DDP-3DDP-1
DS1
NE
DS1
NE
DS3
NE
DS3
NE
Coaxial
Cable
Twisted Pair
Cable1/3 DCS
DS1
PORT
DS3
PORT
DS1
PORT
DS3
PORT
DDP-1 IN 1/3 Application
M
O
I
M
O
I
DS1
NE1
DS1
PORT
A
DS1
PORT
B
DS1
NE2
DDP-1 POS #2
XMIT
RCV
XMIT
RCV
XMIT
RCV
XMIT
RCV
DDP-1 POS #1
Software
Cross-Connects
DCS
DDP Signal Flow
M
O
I
I
O
M
DS1
NE1
DS1
PORT
A
XMIT
RCV
XMIT
RCV
DCS
Chassis
SowareCross-Coecs
o Oher DCS Pors
NE Access DCS Access
DCS Access
Features A cost-effective alternative to hardwiring digital equipment directly to the 1/3 DCS backplane
Smooth, flexible and economical migration of service to a 1/3 DCS in an office
In-service or out-of-service cutover options using DDP-1
Catastrophic access options utilizing the optional jack access card (monitoring in
both directions from one location and patching options)
Ease of adding or removing future network elements
Superior cable management and additional cabling flexibility as the office grows
Economical access solution since permanent jacks are not required for each circuit
7/31/2019 103253 Be
45/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
41T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Rear Access Interconnect Modular System84-Termination DDP-1 Panel
DD1-351001(Front View with
Door Open)
DD1-351001(Front View with
Door Cosed)
DD1-351001(Rear view)
Number oCircuits
CableConnectionsDCS IN/OUT
CableConnectionsNE IN/OUT
CableTermination
AccessMountingOptions
Dimensions(HxWxD)
CatalogNumber
84 Wire-wrap Wire-wrap Rear Flush or 2"recess
WECO/EIA
152 mm x 584 mmx 213 mm
(6" x 23" x 8.4")
DD1-351001
NETWORK
ELEMENT
152 mm(6)
44 mm(1.75)
566 mm(22.3)
584 mm(23)
T
T
DD1-351001
(Rear view)
DD1-351001
(Front View withDoor Open)
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
46/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
42T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
584 mm(23")
566 mm(22")CKT 1 CKT 56
66 mm(2.6")
31.8 mm(1.25")
31.8 mm(1.25")
203 mm(8")
51 mm(2")
Numberof Circuits
CableConnectionsDCS IN/OUT
CableConnectionsNE IN/OUT
CableTermination
AccessMountingOptions
Dimensions(HxWxD)
CatalogNumber
56 Wire-wrap Wire-wrap Rear Flush or51 mm (2")
recessWECO/EIA
66 mm x 584 mm x203 mm
(2.6" x 23" x 8")
DD1-311001
56 Wire-wrap Wire-wrap Rear 121 mm(4.75")
recessWECO/EIA
76 mm x 482 mm x292 mm
(3" x 19" x 11.5")
DD1-211001
Rear Access Interconnect Modular System56-Termination DDP-1 Panel
DD1-311001(Front View with
Door Open)
DD1-311001
(Rear view)
DD1-311001(Front View with
Door Cosed)
Note: chassis color is putty.
DD1-311001(Top View)
DD1-311001(Front View)
O r d e r i n g I n f o r m a t i o n
7/31/2019 103253 Be
47/76
6
/0
7
1
0
3
2
5
3
B
E
DSX-1
43T e c h n i c a l A s s i s t a n c e + 3 2 2 7 1 2 6 5 4 2 e u r o . t a c @ a d c k r o n e . c o m
Rear Access Interconnect Modular SystemDDP-1 Jack Cards
Cards are inserted into the DDP-1 chassis only when equipment installation or maintenance activities arerequired. A variety of cards provide many functions during installation and maintenance activities. Eachaccess card has a lock and release device for secure attachment in the chassis. All cards containing jacksuse industry-standard bantam jacks.
Description Catalog Number
Loopback card; provides loopback of transmit to receive for both the NE and DCS
equipment
DD1-100002
Terminating card; provides 135 Ohm termination across tip and ring for transmit and
receive of both NE and DCS equipment
DD1-100003
Opening card; provides opening of transmission path between NE and DCS (isolates NE
rom DCS or coii esig drig isaaio)
DD1-100004
Jack access card; provides MON, OUT and IN jacks for circuit access to NE equipment andprovides MON, OUT and IN jacks for circuit access to DCS equipment DD1-100005
Drop and insert card; provides MON, OUT and IN jacks for both the NE and DCS
equipment for full duplex circuit access. This provides dual access functionality in
he sige access chassis
DD1-100006
Circuit guard card; provides circuit guard with red label for a single mounting slot