1100 Series 1106A-70TAG2 Diesel Engine – ElectropaK
144.1 kWm net power @ 1500 rpm
www.perkins.com
Photographs are for illustrative purposes only and may not reflect final specification.All information in this document is substantially correct at time of printing and may be altered subsequently. Final weight and dimensions will depend on completed specification. Publication No. PN3054A/12/14 Produced in England ©2014 Perkins Engines Company Limited
Building upon Perkins proven reputation within the power generation industry, the 1100 Series range of ElectropaK engines now fit even closer to customers needs.
In the world of power generation success is only gained by providing more for less. With the 1106A-70TAG Perkins has engineered even higher levels of reliability, yet lowered the cost of ownership.
1100A units are designed for territories that do not require compliance to EPA or EU emissions legislation. These engines are assembled around optimal, efficient manufactuing processes with state-of-the-art technology. They are built to provide the exact power solution for customers who sell their applications into lesser regulated countries.
Focusing on our common platform theme, changes to engine envelope dimensions and connection points have been kept to a minimum.
Specification
Number of cylinders 6 vertical in-line
Bore and stroke 105 x 135 mm 4.13 x 5.31 in
Displacement 7.01 litres 428 in3
Aspiration Turbocharged aftercooled
Cycle 4 stroke
Combustion system Direct injection
Compression ratio 16:1
Rotation Anti-clockwise, viewed on flywheel
Total lubricating capacity 16.5 litres 4.36 US gal
Cooling system Liquid
Total coolant capacity 21 litres 5.5 US gal
www.perkins.com
Photographs are for illustrative purposes only and may not reflect final specification.All information in this document is substantially correct at time of printing and may be altered subsequently. Final weight and dimensions will depend on completed specification. Publication No. PN3054A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1100 Series 1106A-70TAG2 Diesel Engine – ElectropaK
144.1 kWm net power @ 1500 rpm
Features and benefits
Dependable powerl The Perkins® 1106A-70TAG2 delivers up to 165 kVA standby at 50 Hz and 150 kWe standby at 60 Hz, providing
greater productivity through an improved power to weight ratiol This world-class power density has been achieved in a 7 litre engine, using a mechanical fuel injection system;
making this engine robust for all markets, with the ability to cope with the variation of fuel qualities around the world
The 1106A has been designed for excellent load acceptance to ensure your facility is powered quickly at all conditions
Low operating costsl Service intervals are set at 500 hours as standardl Warranties and Service Contracts
We provide one-year warranties for constant speed engines and two-year warranties for variable speed models, as standard. These are supported by multilevel Extended Service Contracts that can be bought additionally Discover more: www.perkins.esc
l Low usage warranty package is also available
World class product supportl Through an experienced global network of distributors and dealers, fully trained engine experts deliver total service
support around the clock, 365 days a year. They have a comprehensive suite of web based tools at their finger tips, covering technical information, parts identification and ordering systems, all dedicated to maximising the productivity of your engine
l Perkins actively pursues product support excellence by insisting our distribution network invest in their territory to provide you with a consistent quality of support across the globe
l Throughout the entire life of a Perkins engine, we provide access to genuine OE specification parts giving 100% reassurance that you receive the very best in terms of quality for lowest possible cost… wherever your Perkins powered machine is operating in the world
l To find your local distributor: www.perkins.com/distributor
www.perkins.com
Photographs are for illustrative purposes only and may not reflect final specification.All information in this document is substantially correct at time of printing and may be altered subsequently. Final weight and dimensions will depend on completed specification. Publication No. PN3054A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1100 Series 1106A-70TAG2 Diesel Engine – ElectropaK
144.1 kWm net power @ 1500 rpm
Technical information
l Tropical radiator pipes and guardsl Flywheel housingl Flywheel and starter ringl Oil filtersl Starter motorl Air cleaners and bracketsl Lubricating oil sumpl Alternatorl Induction manifoldsl Exhaust manifoldsl Fuel filterl Cold start aidl Engine mountings
www.perkins.com
Photographs are for illustrative purposes only and may not reflect final specification.All information in this document is substantially correct at time of printing and may be altered subsequently. Final weight and dimensions will depend on completed specification. Publication No. PN3054A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1100 Series 1106A-70TAG2 Diesel Engine – ElectropaK
144.1 kWm net power @ 1500 rpm
Engine package weights and dimensions
Length with air cleaner 1763 mm 69.4 in
Width 756 mm 29.8 in
Height 1142 mm 145 in
Weight (dry) 788 kg 1737 lb
1763 mm
1142
mm
756 mm
www.perkins.com
Photographs are for illustrative purposes only and may not reflect final specification.All information in this document is substantially correct at time of printing and may be altered subsequently. Final weight and dimensions will depend on completed specification. Publication No. PN3054A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1100 Series 1106A-70TAG2 Diesel Engine – ElectropaK
144.1 kWm net power @ 1500 rpm
Percent of prime powerFuel consumption at 1500 rpm
g/kWhFuel consumption at 1500 rpm
l/hr
110% 201.1 36.1
Prime power 203.3 33.4
75% 199.7 24.7
50% 197.9 16.4
25% 221.1 9.1
Speedrpm
Type of operation
Typical generatoroutput (Net)
Engine power
Gross Net
kVA kWe kWm hp kWm hp
1500Prime power 150 120 136.0 182.4 131.0 175.7
Standby (maximum) 165 132 153.6 206.0 144.1 193.2
UCI274F - Technical Data Sheet
UCI274FSPECIFICATIONS & OPTIONS
STANDARDSNewage Stamford industrial generators meet therequirements of BS EN 60034 and the relevant sectionof other international standards such as BS5000, VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications can be considered onrequest.
VOLTAGE REGULATORS
SX460 AVR - STANDARDWith this self excited control system the main statorsupplies power via the Automatic Voltage Regulator(AVR) to the exciter stator. The high efficiencysemiconductors of the AVR ensure positive build-upfrom initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through athree phase full wave bridge rectifier. This rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit.
AS440 AVRWith this self-excited system the main stator providespower via the AVR to the exciter stator. The highefficiency semi-conductors of the AVR ensure positivebuild-up from initial low levels of residual voltage.The exciter rotor output is fed to the main rotor through athree-phase full-wave bridge rectifier. The rectifier isprotected by a surge suppressor against surges caused,for example, by short circuit or out-of-phase paralleling.The AS440 will support a range of electronicaccessories, including a 'droop' Current Transformer(CT) to permit parallel operation with other acgenerators.
MX341 AVRThis sophisticated AVR is incorporated into the StamfordPermanent Magnet Generator (PMG) control system.The PMG provides power via the AVR to the mainexciter, giving a source of constant excitation powerindependent of generator output. The main exciteroutput is then fed to the main rotor, through a full wavebridge, protected by a surge suppressor. The AVR hasin-built protection against sustained over-excitation,caused by internal or external faults. This de-excites themachine after a minimum of 5 seconds.An engine relief load acceptance feature can enable fullload to be applied to the generator in a single step.If three-phase sensing is required with the PMG systemthe MX321 AVR must be used.We recommend three-phase sensing for applicationswith greatly unbalanced or highly non-linear loads.
MX321 AVRThe most sophisticated of all our AVRs combines all thefeatures of the MX341 with, additionally, three-phaserms sensing, for improved regulation and performance.Over voltage protection is built-in and short circuitcurrent level adjustments is an optional facility.
WINDINGS & ELECTRICAL PERFORMANCEAll generator stators are wound to 2/3 pitch. Thiseliminates triplen (3rd, 9th, 15th …) harmonics on thevoltage waveform and is found to be the optimum designfor trouble-free supply of non-linear loads. The 2/3 pitchdesign avoids excessive neutral currents sometimesseen with higher winding pitches, when in parallel withthe mains. A fully connected damper winding reducesoscillations during paralleling. This winding, with the 2/3pitch and carefully selected pole and tooth designs,ensures very low waveform distortion.
TERMINALS & TERMINAL BOXStandard generators are 3-phase reconnectable with 12ends brought out to the terminals, which are mounted ona cover at the non-drive end of the generator. A sheetsteel terminal box contains the AVR and provides amplespace for the customers' wiring and glandarrangements. It has removable panels for easyaccess.
SHAFT & KEYSAll generator rotors are dynamically balanced to betterthan BS6861:Part 1 Grade 2.5 for minimum vibration inoperation. Two bearing generators are balanced with ahalf key.
INSULATION/IMPREGNATIONThe insulation system is class 'H'.All wound components are impregnated with materialsand processes designed specifically to provide the highbuild required for static windings and the highmechanical strength required for rotating components.
QUALITY ASSURANCEGenerators are manufactured using productionprocedures having a quality assurance level to BS ENISO 9001.
The stated voltage regulation may not be maintained inthe presence of certain radio transmitted signals. Anychange in performance will fall within the limits ofCriteria 'B' of EN 61000-6-2:2001. At no time will thesteady-state voltage regulation exceed 2%.
NB Continuous development of our products entitles usto change specification details without notice, thereforethey must not be regarded as binding.
Front cover drawing typical of product range.
2
CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G.
A.V.R. MX321 MX341
VOLTAGE REGULATION ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT
CONTROL SYSTEM SELF EXCITED
A.V.R. SX460 AS440
VOLTAGE REGULATION ± 1.0 % ± 1.0 % With 4% ENGINE GOVERNING
SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN A SHORT CIRCUIT CURRENT
INSULATION SYSTEM CLASS H
PROTECTION
RATED POWER FACTOR
STATOR WINDING
WINDING PITCH
WINDING LEADS
STATOR WDG. RESISTANCE
ROTOR WDG. RESISTANCE
EXCITER STATOR RESISTANCE
EXCITER ROTOR RESISTANCE
R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others
WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%
MAXIMUM OVERSPEED
BEARING DRIVE END
BEARING NON-DRIVE END
WEIGHT COMP. GENERATORWEIGHT WOUND STATORWEIGHT WOUND ROTORWR² INERTIASHIPPING WEIGHTS in a cratePACKING CRATE SIZE
TELEPHONE INTERFERENCECOOLING AIRVOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138kVA BASE RATING FOR REACTANCE VALUES 160 160 160 N/A 181.3 190 190 206.3
Xd DIR. AXIS SYNCHRONOUS 2.24 2.02 1.88 - 2.53 2.37 2.17 2.16X'd DIR. AXIS TRANSIENT 0.19 0.17 0.16 - 0.21 0.20 0.18 0.18X''d DIR. AXIS SUBTRANSIENT 0.13 0.12 0.11 - 0.14 0.13 0.12 0.12Xq QUAD. AXIS REACTANCE 1.38 1.25 1.16 - 1.53 1.43 1.31 1.31X''q QUAD. AXIS SUBTRANSIENT 0.17 0.15 0.14 - 0.20 0.19 0.17 0.17XL LEAKAGE REACTANCE 0.07 0.06 0.06 - 0.09 0.08 0.08 0.08X2 NEGATIVE SEQUENCE 0.14 0.13 0.12 - 0.16 0.15 0.14 0.14X0 ZERO SEQUENCE 0.08 0.08 0.07 - 0.10 0.09 0.09 0.09
REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATEDT'd TRANSIENT TIME CONST.T''d SUB-TRANSTIME CONST.T'do O.C. FIELD TIME CONST.Ta ARMATURE TIME CONST.SHORT CIRCUIT RATIO
20 Ohms at 22°C
0.091 Ohms PER PHASE AT 22°C
REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7)
BALL. 6310-2RS (ISO)
1.52 Ohms at 22°C
0.024 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED
BALL. 6315-2RS (ISO)
1/Xd
0.035 s0.011 s0.9 s
0.009 s
188.67 kg1.555 kgm2
IP23
0.8
DOUBLE LAYER CONCENTRIC
TWO THIRDS
12
545 kg530 kg200 kg
UCI274F
0.514 m³/sec 1090 cfm 0.617 m³/sec 1308 cfm
50 HzTHF<2%
60 HzTIF<50
177.71 kg1.5044 kgm2
WINDING 311
1 BEARING 2 BEARING
2250 Rev/Min
200 kg
577 kg 123 x 67 x 103(cm)
563 kg 123 x 67 x 103(cm)
3
Winding 311UCI274F
THREE PHASE EFFICIENCY CURVES
50Hz
4
Winding 311UCI274F
THREE PHASE EFFICIENCY CURVES
60Hz
5
UCI274FWinding 311
Locked Rotor Motor Starting Curve
MX SX
50Hz
60Hz
MX SX
0
5
10
15
20
25
30
0 100 200 300 400 500LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
346V 380V 400V 415V
0
5
10
15
20
25
30
0 100 200 300 400 500 600 700LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
380V 416V 440V 460V 480V
0
5
10
15
20
25
30
0 50 100 150 200 250 300 350 400 450LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
346V 380V 400V 415V
0
5
10
15
20
25
30
0 50 100 150 200 250 300 350 400 450 500 550LOCKED ROTOR kVA
PER
CEN
T TR
AN
SIEN
T VO
LTA
GE
DIP
.
380V 416V 440V 460V 480V
6
3-phase 2-phase L-L 1-phase L-NVoltage Factor Voltage Factor x 1.00 x 0.87 x 1.30
380v X 1.00 416v X 1.00 x 1.00 x 1.80 x 3.20400v X 1.07 440v X 1.06 x 1.00 x 1.50 x 2.50415v X 1.12 460v X 1.12 10 sec. 5 sec. 2 sec.
480v X 1.17
UCI274F
50Hz 60Hz
The sustained current value is constant irrespectiveof voltage level
Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated SpeedBased on star (wye) connection.
Max. sustained durationAll other times are unchanged
Instantaneous
SustainedMinimum
Sustained Short Circuit = 750 Amps
Sustained Short Circuit = 920 AmpsNote 1The following multiplication factors should beused to adjust the values from curve betweentime 0.001 seconds and the minimum currentpoint in respect of nominal operating voltage :
Note 2The following multiplication factor should be used to convert thevalues calculated in accordance with NOTE 1 to those applicableto the various types of short circuit :
Note 3Curves are drawn for Star (Wye) connected machines. For otherconnection the following multipliers should be applied to currentvalues as shown : Parallel Star = Curve current value X 2Series Delta = Curve current value X 1.732
50Hz
60Hz
10
100
1000
10000
0.001 0.01 0.1 1 10TIME (secs)
CUR
RENT
(Am
ps)
SYMMETRICAL
ASYMMETRICAL
10
100
1000
10000
0.001 0.01 0.1 1 10TIME (secs)
CUR
RENT
(Am
ps)
SYMMETRICAL
ASYMMETRICAL
7
Class - Temp Rise
Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440
Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220
Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254
kVA 145.0 145.0 145.0 N/A 160.0 160.0 160.0 N/A 170.0 170.0 170.0 N/A 175.0 175.0 175.0 N/A
kW 116.0 116.0 116.0 N/A 128.0 128.0 128.0 N/A 136.0 136.0 136.0 N/A 140.0 140.0 140.0 N/A
Efficiency (%) 92.3 92.6 92.8 N/A 92.0 92.3 92.5 N/A 91.7 92.1 92.3 N/A 91.6 92.0 92.2 N/A
kW Input 125.7 125.3 125.0 N/A 139.1 138.7 138.4 N/A 148.3 147.7 147.3 N/A 152.8 152.2 151.8 N/A
Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480
Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240
Series Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277
kVA 162.5 172.5 172.5 187.5 181.3 190.0 190.0 206.3 187.5 200.0 200.0 212.5 192.5 206.3 206.3 218.8
kW 130.0 138.0 138.0 150.0 145.0 152.0 152.0 165.0 150.0 160.0 160.0 170.0 154.0 165.0 165.0 175.0
Efficiency (%) 92.5 92.7 92.9 92.9 92.1 92.4 92.7 92.7 92.0 92.2 92.5 92.6 91.9 92.1 92.4 92.5
kW Input 140.5 148.9 148.5 161.5 157.5 164.5 164.0 178.0 163.0 173.5 173.0 183.6 167.6 179.2 178.6 189.2
© 2006 TD_UCI274F.GB_10.06_04_GB
Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C
DIMENSIONS
UCI274FWinding 311 / 0.8 Power Factor
RATINGS
Barnack Road • Stamford • Lincolnshire • PE9 2NBTel: 00 44 (0)1780 484000 • Fax: 00 44 (0)1780 484100