24
Daimler AG Technical Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until recalled) Page 1 of 24 SDnetControl Manual SDnetControl Manual Star Diagnosis version Operating system Network Star Diagnosis basic² Star Diagnosis compact³ Star Diagnosis compact³ w Star Diagnosis compact 4 Windows XP LAN WLAN Star Diagnosis Info

110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Embed Size (px)

Citation preview

Page 1: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 1 of 24

SDnetControl Manual

SDnetControl Manual

Star Diagnosis version Operating system Network

Star Diagnosis basic²

Star Diagnosis compact³

Star Diagnosis compact³ w

Star Diagnosis compact4

Windows XP LAN

WLAN

Star Diagnosis Info

Page 2: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 2 of 24

SDnetControl Manual

Objective This document describes the intended use and operation of SDnetControl on Star Diagnosis systems.

Overview of Contents

1 Brief Description of SDnetControl.........................................................................................................................3 1.1 Functions........................................................................................................................................................................... 3 1.2 Target Platforms............................................................................................................................................................... 3 1.3 SDnetAssist Installation Wizard..................................................................................................................................... 3

2 SDnetControl Design ..............................................................................................................................................4 2.1 The Components: Deskband and Program Window ................................................................................................... 4 2.2 The Icons ........................................................................................................................................................................... 4 2.2.1 Hardware Icons ....................................................................................................................................................... 4 2.2.2 Connection Icons .................................................................................................................................................... 4 2.2.3 Multiplexer Icons..................................................................................................................................................... 4

3 The Deskband..........................................................................................................................................................5 3.1 Deskband Display ............................................................................................................................................................ 5 3.2 Hardware Used................................................................................................................................................................. 5 3.3 Set Operating mode ........................................................................................................................................................ 5 3.4 Multiplexer Display .......................................................................................................................................................... 6 3.5 Click-sensitive areas in the deskband .......................................................................................................................... 6

4 The Program Window .............................................................................................................................................8 4.1 Calling Up the Program................................................................................................................................................... 8 4.2 Program Window Structure ............................................................................................................................................ 8 4.3 "Connections" tab ............................................................................................................................................................ 9 4.3.1 Calling Up the Tab................................................................................................................................................... 9 4.3.2 Tab Structure ........................................................................................................................................................... 9 4.3.3 Possible Connection Types.................................................................................................................................... 9 4.3.4 Changing the Operating Mode ............................................................................................................................11 4.3.5 Changing the SDconnect Operating Mode Manually.......................................................................................11

4.4 "Select MUX" Tab...........................................................................................................................................................12 4.4.1 Calling Up the Tab.................................................................................................................................................12 4.4.2 Tab Structure .........................................................................................................................................................12 4.4.3 Selecting a multiplexer.........................................................................................................................................13

4.5 "Configuration" tab ........................................................................................................................................................14 4.5.1 Calling Up the Tab.................................................................................................................................................14 4.5.2 Tab Structure .........................................................................................................................................................14 4.5.3 "Info" topic .............................................................................................................................................................15 4.5.4 "Network" topic .....................................................................................................................................................15 4.5.5 "Server" topic.........................................................................................................................................................18 4.5.6 “MUX” topic ...........................................................................................................................................................19 4.5.7 "Profiles" topic.......................................................................................................................................................20

4.6 "Network tools" tab .......................................................................................................................................................22 4.6.1 Calling Up the Tab.................................................................................................................................................22 4.6.2 Tab Structure .........................................................................................................................................................22 4.6.3 Network Self Diagnosis ........................................................................................................................................23 4.6.4 WLAN Signal Strength ..........................................................................................................................................23 4.6.5 Saving the Configuration......................................................................................................................................24

Page 3: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 3 of 24

SDnetControl Manual

1 Brief Description of SDnetControl

SDnetControl is a new application to control the network connection of your Star Diagnosis system

SDnetControl has two program parts for this:

- A permanently visible status indication in the deskband

- A program window for further information, settings and configurations

1.1 Functions

Daimler AG has introduced Star Diagnosis compact³ w and Star Diagnosis compact4

and the SDconnect multiplexer to keep pace with the major advances in IT. SDnetControl is the central application for

Star Diagnosis systems and SDconnect, allowing users to use the systems' network functions without difficulty:

- Display of information on the current connection status

- Easy changeover of the connection type (e.g. when changing from operation in the workshop to mobile operation)

- Checking network and server availability

SDnetControl is also an important link between current and future applications on Star Diagnosis systems and is

therefore being implemented across multiple platforms.

The following settings can be controlled with SDnetControl:

- "Connections": Setting the operating mode (section 4.3)

- "Select MUX": Selecting a multiplexer (section 4.4)

- "Configuration": Setting up Star Diagnosis systems (section 4.5)

- "Network tools": Display of the availability of application servers and network diagnosis (section 4.6)

Operation of SDnetControl is very intuitive thanks to icons and automatic mechanisms.

1.2 Target Platforms

SDnetControl is designed for all current Star Diagnosis platforms on the Windows XP operating system.

1.3 SDnetAssist Installation Wizard

All necessary configuration settings for SDnetControl can be implemented via the SDnetAssist wizard for setting up

the network. SDnetAssist is a separate application that combines and simplifies the configuration process via a

special input interfaces. It means that configuration for operation in a network can be completed in approximately 10

minutes.

Configuration through SDnetAssist/SDnetControl is only required when the system is to be operated in a network.

Operation outside of networks is possible without configuration.

Calling up the SDnetAssist installation wizard

.

� Programs

� Service

� SDnetAssist

Network questionnaire

Print out the network questionnaire in SDnetAssist and a

printer connected to your Star Diagnosis system or access it

in the INFO information system on your Star Diagnosis

system, or in the After-Sales portal:

http://aftersales.mercedes-benz.com

Then have the questionnaire filled out by your IT

administrator.

4

Page 4: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 4 of 24

SDnetControl Manual

2 SDnetControl Design

SDnetControl is an application that adapts to the Star Diagnosis system in use. This means that various functions

are shown or hidden, depending on the Star Diagnosis variant.

In all variants and also on every tab (cf. section 4.2) in SDnetControl there are “Common functions”. These are the

starting point for the manual. Subsequent to this, all further subjects (such as the configuration of Star Diagnosis

systems) are discussed.

2.1 The Components: Deskband and Program Window

SDnetControl comprises two program areas:

1. Deskband Permanent status indication in the deskband. The deskband is integrated in the task bar of Windows XP in the lower

right corner of the screen. (cf. section 3)

2. Program window

Program window for further information, settings and configurations (see section 4). The program window is called

up by clicking the deskband.

2.2 The Icons

SDnetControl uses icons to simplify the display. These are briefly presented below and will be described in more detail

in later sections as necessary.

2.2.1 Hardware Icons

The hardware icons represent the relevant Star Diagnosis

components in the workshop's network. They differentiate

between the server, the Star Diagnosis platform and the

multiplexer.

These differ again depending on the platform and

multiplexer used.

Icon for server/Internet

Icons for Star Diagnosis

systems

Icons for multiplexers

2.2.2 Connection Icons

Connection icons serve to illustrate the type of connection

between the various hardware components.

The difference in color does not refer to the connection

status. It only serves to make differentiation easier.

The connection icons are explained in more detail in

section 4.3.

Cable Connection

Road Wireless Network (WLAN adhoc):

Workshop Wireless Network (WLAN infrastructure):

No Connection

2.2.3 Multiplexer Icons

The status icon for the multiplexer informs the user of the

multiplexer selected and its availability. Details for this can

be found in section 3.4.

Multiplexer status indication (see section 3.4)

Page 5: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 5 of 24

SDnetControl Manual

3 The Deskband

As a part of SDnetControl, the deskband shows the network connection of Star Diagnosis systems and multiplexers

permanently and at all times.

3.1 Deskband Display

The deskband is integrated in the task bar of Windows XP

in the lower right corner of the screen.

Information about the hardware used, the selected

connection type and the status of the selected multiplexer

is displayed.

The color of the icon does not provide any information

about the status of the selected connection, in other

words whether it is actually functional. In order to check

this you can use the network tools (see section 4.6).

3.2 Hardware Used

The display in the deskband changes according to the

hardware used.

So for example, a multiplexer that is selected via cable is

automatically displayed as an icon and as "connected via

cable" (applies particularly when using a Part D).

3.3 Set Operating mode

The display in the deskband adapts to the operating mode

selected and the hardware used (see also section 4.3)

The connection type is displayed in the workshop

network/Internet on the left side of the Star Diagnosis

system.

The connection type to the multiplexer is displayed on the

right side of the Star Diagnosis system.

Explanation of the example above:

Left: The Star Diagnosis system is connected to the workshop server/Internet via a cable. A compact³ or compact³ w

is being used.

Right: The Star Diagnosis system is connected to the multiplexer via a cable. An SDconnect is being used. The

No connection

Workshop wireless network (WLAN infrastructure)

Cable connection (LAN)

Road wireless network (WLAN adhoc)

Workshop wireless network (WLAN infrastructure)

Cable connection (LAN)

Operating modes

SD system –

Wireless SD system –

Multiplexer

Star Diagnosis

System

Multiplexer Workshop

Network /

Star Diagnosis compact³ w with SDconnect

compact4 SDconnect

Star Diagnosis compact³

with Part D compact³ Part D

Star Diagnosis basic²

with Part D basic² Part D

Star Diagnosis compact³ w with SDconnect

compact³ w SDconnect

Page 6: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 6 of 24

SDnetControl Manual

SDconnect has been assigned the name "30."

3.4 Multiplexer Display

The deskband displays information on the multiplexer:

Selected multiplexer

1. No multiplexer selected (e.g. status when delivered) 2. Part D selected (automatic selection) 3. SDconnect (numbers 1 to 40) selected

Multiplexer connection status

1. Not accessible - the multiplexer has been selected but is not accessible

2. Accessible - the multiplexer has been selected and is accessible

3. Connected – the multiplexer has been selected and an application is accessing the multiplexer at the moment.

See also section 3.

"Multiplexer" icon combination

3.5 Click-sensitive areas in the deskband

The deskband has 3 click-sensitive areas. Various

functional areas (shown in a tab) of the SDnetControl

program window can be called up by clicking in one of

these areas:

- "Network tools"

- "Connections"

- "Select MUX"

There is also a configuration tab. This cannot be called up

directly (cf. section 4.5).

- "Configuration"

Status of the multiplexer selection

1. No multiplexer selected

2. Part D selected (automatic selection)

3. SDconnect is selected:

- No. of SDconnect

- colored assignment of the no.

- -

21-30

11-20 31-40

1-10

D

Selection of

multiplexer

Status of the multiplexer connection

1. Multiplexer is not accessible

2. Multiplexer is accessible

3. Multiplexer is connected

Selection of

multiplexer

No multiplexer selected,

no multiplexer accessible.

SDconnect "30" selected,

multiplexer not accessible.

SDconnect "30" selected

multiplexer accessible, (here: SDconnect no. "30").

SDconnect "30" selected,

multiplexer accessible & connected, (here: no. "30").

Similar representation for Part D,

Here: Part D selected automatically and accessible.

Connections

Select

MUX

Network tools

Page 7: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 7 of 24

SDnetControl Manual

SDnetControl offers various functional areas that are

summarized in the various tabs of the application window:

A) "Connections"

Configuration of the operating mode/connection type

B) "Select MUX"

Selection of the multiplexer

C) "Configuration"

Configuration of the Star Diagnosis system

D) "Network tools"

Checking server availability and network diagnosis

Details for this can be found in section 4.

A) B)

C) D)

SDnetControl adapts to the hardware currently in use. The available options and functions may

vary according to the hardware.

Functions that are not available in SDnetControl are hidden.

Available functions are used in the same way across all platforms. These instructions do not

discuss individual platforms.

Page 8: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 8 of 24

SDnetControl Manual

4 The Program Window

SDnetControl is called up via the deskband. The deskband is a part of SDnetControl and shows important settings.

4.1 Calling Up the Program

Call up SDnetControl by clicking in the deskband.

Please note that there are three click-sensitive areas in the deskband. Depending on which one is clicked, these call

up different views in the SDnetControl program window (see section 3.5)

Note:

Once the program window has been closed, the indicator remains visible in the deskband.

4.2 Program Window Structure

The SDnetControl program window is divided into three areas:

- Navigation area (tabs and panels):

Top navigation level in SDnetControl. The number of tabs and the panels summarized in them differ depending on

the Star Diagnosis variant in use.

- Display and configuration area:

SDnetControl information is shown and changes in SDnetControl are made here.

- Function area:

Click "OK" to save all changes that were made and close the window. Click on cancel to discard these changes

and close the window.

Function area in SDnetControl

- Confirm entries/changes

- Cancel/discard changes

Display and configuration area

- Read out information

- Enter/change parameters

Navigation area (tabs and panels)

Page 9: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 9 of 24

SDnetControl Manual

4.3 "Connections" tab

4.3.1 Calling Up the Tab

On the "Connections" tab in SDnetControl, you can set up the operating modes. The Star Diagnosis system must have

been configured accordingly during the configuration process. You can call up the Connections tab directly by clicking

in the center of the deskband:

4.3.2 Tab Structure

On the left the connection for the

Star Diagnosis system to the

workshop network/ Internet is

determined.

On the right the connection of the

multiplexer to the Star Diagnosis

system is set.

The cable connection is recognized

automatically on inserting the

connection cable and it cannot be

selected.

Not all connection combinations are possible. SDnetControl prevents impossible combinations, and hides connections

types that are not available, when there is no WLAN card installed, for example.

It is not possible to simultaneously operate workshop wireless network on the Star

Diagnosis system and road wireless network on SDconnect.

4.3.3 Possible Connection Types

There are various different ways of connecting your complete Star Diagnosis system to your workshop network.

Furthermore, there are various different ways of connecting your Star Diagnosis system to SDconnect. You can select

between the configured types of connection and adjust them to your particular requirements.

Multiplexer Workshop network/

Internet

No Connection Workshop WLAN Cable Connection Cable Connection Workshop WLAN Road WLAN

Workshop

network/ Multiplexer

Page 10: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 10 of 24

SDnetControl Manual

4.3.3.1 Connection from the Star Diagnosis system to

the workshop network/Internet

4.3.3.2 Connection from the Star Diagnosis system to

the multiplexer

Cable Connection (LAN):

For connecting the Star Diagnosis system via network

cable to the workshop network/Internet.

Cable Connection (LAN):

The multiplexer is connected via the cable. The cable

connection to the multiplexer is automatically recognized

and does not require prior configuration.

Workshop Wireless Network (WLAN infrastructure):

For the connection of the Star Diagnosis system via

wireless network. This is only possible with a wireless

station (access point) within the workshop.

Workshop Wireless Network (WLAN infrastructure):

For connection of the multiplexer via wireless network.

This is only possible with a wireless station (access point)

within the workshop.

- Road wireless network is not possible - Road Wireless Network (WLAN adhoc):

For the connection of the multiplexer via wireless network

without a wireless station (access point). This operating

mode is intended for mobile use outside of the workshop.

No Connection:

The Star Diagnosis system should not have access to the

workshop network/Internet (standalone use).

No data access takes place via the Internet. Diagnostic

procedures with online access such as online coding of

control units are not possible either.

No Connection:

Delivery status, cannot be selected.

All the icons listed are displayed in the deskband by the SDnetControl application, this enables the user to always

have the network connection setting of the Star Diagnosis system in view. Further information can be found in section

3.

The use of wireless communication networks and the use of systems in these networks must meet the

appropriate rules and regulations of your country. More information can be obtained from the relevant

authorities. Make sure you know the country-specific conditions for operation of wireless

communication networks in your market. If necessary, remove a non-approved wireless card from the

SDconnect.

Information about the system can be found in the documentation enclosed with the Star Diagnosis

delivery package and the documents provided in the INFO information system.

An additional wireless card is required for the wireless network in some markets and for certain

systems. Ask your market representative if your Star Diagnosis system is suitable for wireless

operation in your market or look in the After-Sales portal at http://aftersales.mercedes-benz.com.

Workshop network/

Internet Multiplexer

Page 11: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 11 of 24

SDnetControl Manual

4.3.4 Changing the Operating Mode

To change the operating mode, call up the Connections tab by clicking in the center of the deskband:

In the left area click the connection

type you wish to use to connect

your Star Diagnosis system to the

workshop network/Internet.

In the right area click the

connection type you wish to use to

connect your Star Diagnosis system

to your SDconnect.

Note that the cable connection is

automatically selected and cannot

be selected manually.

Confirm your selection by clicking "OK."

4.3.5 Changing the SDconnect Operating Mode Manually

In order to be able to operate an SDconnect with a Star Diagnosis system, the same operating mode must be set on

both systems. However, after fully configuring your system, it is possible that the operating mode does not

automatically change in SDconnect along with changes in SDnetControl, as is intended. Be aware of the following

indications:

The icons shown in the deskband and on the SDconnect

display do not match.

After switching from road wireless network to workshop

wireless network, for example, SDconnect cannot be

reached.

The following icon is displayed in the deskband:

Details in section 3.4.

Manual change of the SDconnect operating mode

Press once and confirm with .

See the respective chapter in the SDconnect manual.

Requirements:

- WLAN card installed

- WLAN mode active

- No cable connection used.

or

deskband in the SDconnect display

and in the

deskband.

Workshop

network/ Multiplexer

Page 12: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 12 of 24

SDnetControl Manual

4.4 "Select MUX" Tab

4.4.1 Calling Up the Tab

Click in the right area of the deskband to call up the tab for multiplexer selection. The "Select MUX" tab is called up

in the SDnetControl user interface.

4.4.2 Tab Structure

Multiplexer list

More than one SDconnect can be available for

selection via a wireless network connection. These are

shown in a list if you use multiple SDconnects in your

workshop. All SDconnect units are displayed with their

status and detailed information.

If you work with a Part D, this will be shown as the only

multiplexer (as they are connected via cable).

Function button for selecting and searching SDconnect

(not Part D), as well as confirming or rejecting entries.

1

2

1

2

Page 13: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 13 of 24

SDnetControl Manual

4.4.3 Selecting a multiplexer

Before an application can use the multiplexer, the latter has to be selected. A distinction is made between two kinds of

selections:

1. automatic: all multiplexers are recognized automatically when connected to the Star Diagnosis system via a cable 2. manual selection: all the SDconnects known to the wireless network are shown in this list. The SDconnect desired

must be selected manually.

If the device is accessible, then the SDconnect most recently selected will automatically be used at every restart of the

application. If a different SDconnect is to be selected, the tab "Select MUX" can be opened by clicking the icon in the

right-hand side of the deskband.

In order to be able to select an SDconnect, no multiplexer

may be connected via a cable!

A list shows all the SDconnects known to the

wireless network. Select an SDconnect with a status of

“Available” by clicking on the number and then click on

“Select”.

Select an SDconnect as above. Clicking on the

"Test signal" button causes the SDconnect selected to

emit an acoustic signal. In this way you can check for a

correct connection, for instance.

Note on type of connection:

Note that an SDconnect can only be displayed as

“Available” here if the Star Diagnosis system and the

SDconnect are in the same type of connection (see

section 4.3.4 and 4.3.5).

You can see whether both systems are in the same type of

connection (here: “Road wireless network”) from the

appropriate displays in the system.

++

++

1

2

3

1 2

3

deskband in the display

in the deskband

Page 14: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 14 of 24

SDnetControl Manual

4.5 "Configuration" tab

4.5.1 Calling Up the Tab

Note that the "Configuration" tab cannot be called up directly. Click in one of the deskband's

three click-sensitive areas and then change to the "Configuration" tab.

The Star Diagnosis system is configured for use in networks on the "Configuration" tab in SDnetControl. Here the

SDconnect can also be configured in Expert mode, unless the SDnetAssist configuration wizard is being used.

Once you have clicked "Configuration", you have to confirm a warning notice that changing the configuration can

impair the fault-free functioning of the system:

Click on “No” if you do not wish to change the configuration. Only Info is shown on the tab.

If you confirm this prompt with “Yes”, all the topics explained below will be displayed.

4.5.2 Tab Structure

The various topics are presented and described in detail in the following.

The configuration of a Star Diagnosis system

is carried out via the following topics:

"Info": Overview of configuration settings

"Network": Configuration of all network settings

"Server": Configuration of all application servers

“MUX”: SDconnect multiplexer configuration

"Profiles": Administration of various user profiles

Each topic (here network) has different setting options.

Note: The "Info" topic is always shown after the above prompt

is confirmed.

Page 15: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 15 of 24

SDnetControl Manual

4.5.3 "Info" topic

The Star Diagnosis system settings are shown in the "Info" topic.

"Info" provides you with a compact overview of the

current configuration settings of your Star Diagnosis

system.

4.5.4 "Network" topic

The "Network" topic summarizes network-related setting options, which are defined below.

4.5.4.1 Network adapter

The LAN and WLAN adapters can be activated or

deactivated here.

The Star Diagnosis system's MAC addresses are also

shown here.

Recommendation:

The network adapters should be activated in order to

be able to use the full range of functions.

Page 16: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 16 of 24

SDnetControl Manual

4.5.4.2 Computer name

Your Star Diagnosis system's computer name is

shown.

You can change this name.

Recommendation:

Do not change the name shown.

4.5.4.3 Workshop cable network

The parameters for a Star Diagnosis system LAN

connection are entered here.

These parameters depend on the settings in your

workshop.

Required information:

IP address for your Star Diagnosis system

Subnet mask for your Star Diagnosis system

Default gateway for your Star Diagnosis system

Preferred DNS server

Alternative DNS server

If you do not have the required information, please

contact your network administrator.

Example

Example

Page 17: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 17 of 24

SDnetControl Manual

4.5.4.4 Workshop WLAN

The parameters for connecting your Star Diagnosis

system to your workshop WLAN are entered here.

These parameters are only needed if you use a

WLAN in your workshop.

Required information:

IP address for your Star Diagnosis system

Subnet mask for your Star Diagnosis system

Default gateway for your Star Diagnosis system

Preferred DNS server

Alternative DNS server

Network name (SSID)

Network authentication

Key format ASCII or hexadecimal

Network key (enter twice)

If you do not have the required information, please

contact your network administrator.

IMPORTANT:

Please note that the IP address of your Star

Diagnosis system must be different to the IP

address for your SDconnect. They may not be the

same.

4.5.4.5 Road WLAN

The data for the adhoc network are entered here, so

that SDconnect and the Star Diagnosis system can

communicate with each other.

Required information:

Each Star Diagnosis system must have a unique IP

address, e.g.: 192.168.2.222.

(permissible numbers: "01" - "54")

IP address xxx.xxx.x.2_ _

Subnet mask

Network name (SSID)

Network authentication

Key entry format

Key

Repeat key

IMPORTANT:

Please note that the IP address of your Star

Diagnosis system must be different to the IP

address for your SDconnect. They may not be the

same.

Example

Example

Page 18: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 18 of 24

SDnetControl Manual

4.5.4.6 Country configuration

You can configure your Star Diagnosis system for the

conditions in your country here.

Select the suitable country setting for you from the

dropdown menu.

The use of wireless communication networks and the use of systems in these networks must

meet the appropriate rules and regulations of your country. More information can be obtained

from the relevant authorities. Make sure you know the country-specific conditions for operation

of wireless communication networks in your market. If necessary, remove a non-approved

wireless card from the SDconnect.

Information about the system can be found in the documentation enclosed with the Star

Diagnosis delivery package and the documents provided in the INFO information system.

An additional wireless card is required for the wireless network in some markets and for

certain systems. Ask your market representative if your Star Diagnosis system is suitable for

wireless operation in your market or look in the After-Sales portal at

http://aftersales.mercedes-benz.com.

4.5.5 "Server" topic

A proxy server and the settings for EPCnet, WIS/ASRA

net can be configured on the server configuration

topic.

Please compare the entries in this screen with those

on the "SDnetAssist questionnaire" that your IT

administrator filled out when the system was

Country Settings

Page 19: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 19 of 24

SDnetControl Manual

configured.

(Also see section 3 for initial setup in the SDconnect

manual).

EPCnet, WIS/ASRA net server specifications are not

covered by the system configuration with SDnetAssist

and must be entered here separately.

The Online/Offline setting for EPCnet, WIS/ASRA net

is configured for Xentry only and does not apply for

DAS.

Note that a Star Diagnosis system must be enabled for use in a LAN/WLAN network. Ask

your system administrator.

Information on the MAC addresses can be found in the SDconnect manual and in section 3..

4.5.6 “MUX” topic

The “MUX” topic summarizes information and configuration options related to the SDconnect in what is known as the

SDconnect Toolkit. The functions are described in the following section.

“Information”:

Call to provide information regarding the SDconnects

used.

“Register/configure”

Call to configure an SDconnect or to change

configuration settings.

“Self-diagnosis”

Call to run SDconnect self-diagnosis in the event of

problems.

“Software update”

Call to modify the software on an SDconnect in the

event of problems.

The SDconnect toolkit built into SDnetControl may be considered an “Expert mode”. The

configurations of the SDconnect required are also performed by SDnetAssist.

Example

Page 20: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 20 of 24

SDnetControl Manual

4.5.7 "Profiles" topic

4.5.7.1 Profile administration without USB data

storage devices

Here you can load, save and display profiles or import

profiles from USB devices.

Load a profile by selecting one that is

displayed in the table and clicking "Load."

Save the profile data you entered in a

profile. You can choose any name you want,

for the profile except for "default."

Delete a profile by clicking "Delete"

Show the parameters of a profile by

selecting the desired profile and clicking

"Show."

See section

4.5.7.2 for details.

Page 21: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 21 of 24

SDnetControl Manual

4.5.7.2 Profile administration with USB data

storage devices

Before you can save a profile on a USB data storage

device or load a profile from a USB data storage

device, you must connect it to the USB interface of

your Star Diagnosis system.

Click "USB storage device" (see page 20) to call up

this interface.

You can select from the following in the "USBWizard":

- Loading a profile from a USB data storage device

to the hard drive

- Saving a profile to a USB data storage device

Note:

The term configuration means the settings in a profile

here.

Follow the instructions on the screen to load or save a

profile.

Page 22: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 22 of 24

SDnetControl Manual

4.6 "Network tools" tab

4.6.1 Calling Up the Tab

Click in the left area of the deskband to call up the tab for the network tools. The "Network tools" tab is called up in

the SDnetControl user interface.

4.6.2 Tab Structure

The result of the quick test for the network is shown in

the network tools tab.

Furthermore, the accessibility of the following

application servers is displayed:

- SD Online Update

- Xentry Flash

- SDremote

- “EWAnet Url” (not on Star Diagnosis basic²)

Meanings of the icons used

Connection established

No connection

Checking connection

No action

Additional network tools:

- Self-diagnosis of the network and

- display of the WLAN signal strength

4.6.3 Reconnect workshop cabled network

If you have selected the DHCP option in workshop cabled network connections and you cannot establish a connection

to the network, you will see this message:

Check the cable connection and start a new attempt to connect to the workshop cabled network by clicking on “OK”.

You may also use the “Reconnect workshop cable network” button.

1

2

3

1

2

3

4 4

Page 23: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 23 of 24

SDnetControl Manual

4.6.4 Network Self Diagnosis

The network self-diagnosis opens in Star Utilities after you

click "Network self-diagnosis."

Click "Start" for a simple diagnosis and "Expanded..." for

an advanced diagnosis

Follow the steps.

4.6.5 WLAN Signal Strength

On the "Network tools" tab in SDnetControl, click "WLAN

signal strength."

The signal strength is shown.

Check "Icon in Systray" to display the WLAN reception

status permanently in the Windows system tray.

Page 24: 110314 Handbuch SDnetControl en 1 - Agson.Netagson.net/images/mb/handbuch_sdnetcontrol_en_ Information/Workshop Equipment (GSP/OI) HPC R800 D-70546 Stuttgart Status 03/11 (valid until

Daimler AG

Technical Information/Workshop Equipment (GSP/OI)

HPC R800 D-70546 Stuttgart

Status 03/11 (valid until recalled)

Page 24 of 24

SDnetControl Manual

4.6.6 Saving the Configuration

IMPORTANT:

Click on "OK" before finishing the configuration of

SDconnect and the Star Diagnosis system. SDnetControl

closes automatically.

Then open SDnetControl again and save your configuration

in a profile.

See section 4.5.7.